VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR ******************************************************** * * * SHUTTLE COUNTDOWN (LPS) * * * ******************************************************** * EFFECTIVITY CATEGORY: A * * HA-SVTBAMDGQ * * CWZF+ER * * CENTER: KSC * * SYSTEM: TCO * * SITE: PAD A/B * * * * VEHICLE: OV-102/103/104/105 * * * * FLOW: ALL * * * * DESIGN CENTER CONCURRENCE: JSC & MSFC * ******************************************************** . VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR UNITED SPACE ALLIANCE ******************************************************** * * * SHUTTLE COUNTDOWN (LPS) * * * ******************************************************** * EFFECTIVITY CATEGORY: A * * HA-SVTBAMDGQ * * CWZF+ER * * CENTER: KSC * * SYSTEM: TCO * * SITE: PAD A/B * * * * VEHICLE: OV-102/103/104/105 * * * * FLOW: ALL * * * * DESIGN CENTER CONCURRENCE: JSC & MSFC * ******************************************************** PREPARED BY: _________________________________ SFOC TEST DOCUMENTATION APPROVED BY: CONTRACTOR _________________________________ SFOC SAFETY ------------------------------------------------------------------ THIS PROCEDURE CONTAINS HAZARDOUS OPERATIONS ------------------------------------------------------------------ . VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR REVISION RECORD PAGE -------------------- REV-CHANGE DATE REASON PAGES AFFECTED EFFECTIVITY --------------------------------------------------------------------- CM : 03-19-98 : 128/USK217: ALL : STS90 & SUBS : : RCN : : : : KV13253 : : : : KV13251 : : : : OV13040M : : : : OV13008 : : : : PP04839M1 : : : : MS13289 : : -----------:----------:-----------:--------------------:------------- CN : 05-19-98 : 129/USK023: ALL : STS91 & SUBS : : RCN : : : : SS13373 : : --------------------------------------------------------------------- CO : 09-29-98 : 130/USK217: ALL : STS95 & SUBS : : RCN : : : : KS13250 : : : : KV13253M : : : : KS13486 : : --------------------------------------------------------------------- CP : 11-16-98 : 131/USK217: ALL : STS88 & SUBS --------------------------------------------------------------------- CQ : 05-05-99 : 132/USK023: ALL : STS96 & SUBS ---------------------------------------------------------------------| CR : 07-07-99 : 133/USK206: ALL : STS93 & SUBS| --------------------------------------------------------------------- . VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR TABLE OF CONTENTS ----------------- PAGE ---- COVER PAGE APPROVAL PAGE/CHANGE RECORD PAGE TABLE OF CONTENTS OBJECTIVE/DESCRIPTION ..................................... NA ILLUSTRATIONS ............................................. 1 HAZARDOUS MANLOADING ...................................... NA BAR CHARTS ................................................ 15 SECTION I - INFORMATION 1.1 REFERENCED INSTRUCTIONS........................... 16 1.2 COMPUTER SYSTEMS ................................. NA 1.3 SPECIAL TOOLS, EQUIPMENT AND MATERIALS ........... NA 1.4 SUPPORT TOOLS, EQUIPMENT AND MATERIALS ........... NA 1.5 PERSONNEL REQUIREMENTS ........................... NA 1.6 SAFETY REQUIREMENTS .............................. NA 1.7 SPECIAL INSTRUCTIONS ............................ NA 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP........... 31 SECTION II - PRE-OPERATION SETUP INSTRUCTIONS NA SECTION III - OPERATION SUPPORT SETUP INSTRUCTIONS NA SECTION IV - OPERATION INSTRUCTIONS 13-0000 CALL TO STATION.............................. 73 14-0000 SHUTTLE COUNTDOWN CONTROL SEQUENCE (-43H THRU -11H)........................................ 81 15-0000 SHUTTLE COUNTDOWN CONTROL SEQUENCE (-11H THRU -6H).......................................... 501 16-0000 SHUTTLE FINAL COUNTDOWN CONTROL SEQUENCE (-06H THRU T-0).................................... 677 16-1153 RSLS ABORT SAFING............................ 948 16-1155 BFS ENGAGE ABORT SAFING...................... 959 16-1159 POST ABORT SAFETY CHECKS...................... 973 17-0000 POST LAUNCH SECURING/RTLS CONTINGENCY........ 975 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 18-0000 RECYCLE CONTROL SEQUENCE...................... 1071 19-0000 ORBITER RECYCLE.............................. 1099 20-0000 SRB RECYCLE.................................. 1125 21-0000 ET RECYCLE.................................... 1137 22-0000 SUPPORT RECYCLE.............................. 1141 23-0000 MCCH RECYCLE.................................. 1153 24-000 PAYLOAD IUS RECYCLE.......................... 1163 25-000 RESERVED...................................... 1165 26-000 RESERVED...................................... 1167 27-000 LATE CABIN VENT CONTINGENCY OPTION............ 1169 28-000 HOLD OPTION NO. 1 - UNPLANNED LONG DURATION BETWEEN T-9 MIN AND T-5 MIN.................. 1171 SECTION V - POST OPERATION INSTRUCTIONS NA APPENDICES A THRU Y .............................................. NA Z EMERGENCY INSTRUCTIONS ....................... 1183 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR LIST OF ILLUSTRATIONS --------------------- PAGE ---- FIGURE 1 KSC/WSSH COMM REQUIREMENTS............... 2 FIGURE 2 KSC (CX-39) TO DFRF AND SPECIFIED LOCAL DFRF COMM REQUIREMENTS................... 3 FIGURE 3 SPECIFIED KSC (CX-39) SLF COMM REQUIREMENTS............................. 4 FIGURE 4 EXCLUSIVE USAGE CAMERA MATRIX (SHEETS 1, 2, AND 3)..................... 5 FIGURE 5 LC-39 CONTROL AREAS AND ROADBLOCKS....... 8 FIGURE 6 SLF CONTROLLED AREA...................... 9 FIGURE 7 LDA MANLOADING........................... 10 FIGURE 8 RSLS (ON BOARD) S/W & GLS (GND) S/W INTERACTION: T-38 SEC TO T-0............ 11 FIGURE 9 LAUNCH COUNTDOWN FLOW.................... 12 FIGURE 10 ALLOWABLE WIND CONDITIONS FOR PAD LH2 AND GH2 WASHDOWNS........................ 13 FIGURE 11 PLBD MOISTURE CONDITIONING REQUIREMENT FOR GROUND PROCESSING FLOW SCHEDULE OV-102 AND SUBS.......................... 14 1 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 1 - KSC/WSSH COMM REQUIREMENTS (FOR REFERENCE ONLY) 2 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 2 - KSC (CX-39) TO DFRF AND SPECIFIED LOCAL DFRF COMM REQUIREMENTS (FOR REFERENCE ONLY) 3 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 3 - SPECIFIED KSC (CX-39) SLF COMM REQUIREMENTS (FOR REFERENCE ONLY) 4 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 4 - EXCLUSIVE USAGE CAMERA MATRIX (SHEET 1 OF 3) (FOR REFERENCE ONLY) 5 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 4 - EXCLUSIVE USAGE CAMERA MATRIX (SHEET 2 OF 3) (FOR REFERENCE ONLY) 6 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 4 - EXCLUSIVE USAGE CAMERA MATRIX (SHEET 3 OF 3) (FOR REFERENCE ONLY) 7 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 5 - LC-39 CONTROL AREAS AND ROADBLOCKS (FOR REFERENCE ONLY) 8 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 6 - SLF CONTROLLED AREA (FOR REFERENCE ONLY) 9 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 7 - LDA MANLOADING 10 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 8 - RSLS (ONBOARD) S/W & GLS (GND) S/W INTERACTION: T-38 SEC TO T-0 (FOR REFERENCE ONLY) 11 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 9 - LAUNCH COUNTDOWN FLOW (FOR REFERENCE ONLY) 12 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 10 - ALLOWABLE WIND CONDITIONS FOR PAD LH2 AND GH2 WASHDOWNS (FOR REFERENCE ONLY) 13 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR FIGURE 11 - PLBD MOISTURE CONDITIONING REQUIREMENT FOR GROUND PROCESSING FLOW SCHEDULE, OV-102 AND SUBS (FOR REFERENCE ONLY) 14 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR NOTE BAR CHART IS PRINTED AND DISTRIBUTED SEPARATELY. REFERENCE KSC INTEGRATED CONTROL SCHEDULE FOR PRELIMINARY AND FINAL BAR CHARTS. BAR CHART 15 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR SECTION I INFORMATION ----------- 1.1 REFERENCED INSTRUCTIONS ----------------------- 1.1.3 SUPPORTING SUBTASKS | | SUBTASK SUBTASK TITLE/ CALLING | NUMBER FUNCTION TO BE PERFORMED SEQ-STEP| ------- -------------------------- --------| | M3034 PRESSURIZING AIR SYS,PADS A/B 14-0009 | | S9001VL2 SHUTTLE POWER UP/POWER DOWN (LPS) 14-0019 | 14-0046 | | C2000 LCC CCMS OPERATION SUPPORT 14-0053 | | S9001VL1 SHUTTLE POWER UP/POWER DOWN (LPS) 14-0085 | | V9001VL2 ORBITER POWER UP/POWER DOWN, DPS | OPTIONS (LPS) 14-0106 | | V33-00012 MCDS OTV CAMERA/BRACKET AND OIS UNITS | REMOVAL 14-0114 | | S9001VL2 SHUTTLE POWER UP/POWER DOWN (LPS) 14-0117 | | G6304 LH2/LOX SYSTEMS PURGE VERIFICATION 14-0126 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-0128 | | V9021.002 OMS/RCS TRICKLE PURGE | ACTIVATION/DEACTIVATION 14-0129 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-0142 | 14-0143 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) 14-0157 | | V66-90006 PLATFORM ACCESS SET, A70-0558 MIDDECK, | CREW MODULE VERTICAL, REMOVAL 14-0165 | | V66-50009 INSTALLATION/REMOVAL AIRLOCK OUT | VERTICAL ACCESS SET - CREW MODULE 14-0166 | | V3540 HGDS (U72-1186) B/U HGDS (U72-1350) | HUMS (C72-1502) OPERATIONAL SUPT 14-0172 | 16 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR | V66-00019 PLATFORM ACCESS SET A70-0558 AFT | FLIGHT DECK INSTALLATION/REMOVAL 14-0174 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 14-0177 | | V80-95903 DOOR 59-03, OMS ENGINE LH SERVICE | ACCESS, INSTALLATION 14-0178 | | V80-95904 DOOR 59-04, OMS ENGINE RH SERVICE | ACCESS, INSTALLATION 14-0178 | | G3151 LOX SYSTEM PREPS FOR VEHICLE LOADING 14-0180 | | G3251 LH2 SYSTEM PREPS FOR VEHICLE LOADING | (LPS) 14-0181 | | M3067 CABIN AIR(OXYGEN/NITROGEN) | DISTRIBUTION SYSTEM 14-0187 | 14-0188 | 14-0189 | | V66-50009 INSTALLATION/REMOVAL AIRLOCK OUT | VERTICAL ACCESS SET - CREW MODULE 14-0190 | | V66-90006 PLATFORM ACCESS SET, A70-0558 MIDDECK, | CREW MODULE VERTICAL, REMOVAL 14-0190 | | V5097.003 CREW SYSTEMS STOWAGE - FLIGHT | DECK/MIDDECK 14-0191 | | V66-00019 PLATFORM ACCESS SET A70-0558 AFT | FLIGHT DECK INSTALLATION/REMOVAL 14-0192 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-0193 | | V80-95903 DOOR 59-03, OMS ENGINE LH SERVICE | ACCESS, INSTALLATION 14-0222 | | V80-95904 DOOR 59-04, OMS ENGINE RH SERVICE | ACCESS, INSTALLATION 14-0222 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 14-0242 | | M3067 CABIN AIR(OXYGEN/NITROGEN) | DISTRIBUTION SYSTEM 14-0245 | | Z3D00 DUAL TACAN BEACON 9946 FLT SUPPORT 14-0249 | | V3528.001 COMM AND TRACK STATION SETUP AND | OPERATION - OPF (HB1/2) 14-0266 | 17 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR | V3528.002 COMM AND TRACK STATION SETUP AND | OPERATION - OPF BAY 3 14-0267 | | V3528.001 COMM AND TRACK STATION SETUP AND | OPERATION - OPF (HB1/2) 14-0269 | | V3528.002 COMM AND TRACK STATION SETUP AND | OPERATION - OPF BAY 3 14-0269 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 14-0273 | | M3079 AC,VENTILATING,PRESSURIZING SYS,MLP 14-0280 | | B5150 SUPPORT EQUIPMENT REMOVAL AND | INSTALLATION 14-0307 | | M3022 COMPRESSED AIR SYSTEM 14-0316 | | M3088 LOW-LEVEL OXYGEN ANALYZER UNITS | OPERATION 14-0319 | | D3008 PURGE/PRESSURIZATION AND LOCKOUT | PROCEDURES FOR COMM ENCLOSURES 14-0342 | | D3012 OMI RECORD IS NOT IN THE DATABASE 14-0360 | 14-0361 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | CONTROL STATION 132 TRANSFER PAD TO | FIRING ROOM 14-0375 | | S9001VL1 SHUTTLE POWER UP/POWER DOWN (LPS) 14-0390 | 14-0456 | 14-0460 | | M3034 PRESSURIZING AIR SYS,PADS A/B 14-0479 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | PREPS FOR AIR GN2 132 CHANGEOVER | OPTION B - FINAL SU72166 PREPS 14-0492 | 14-0496 | | M3034 PRESSURIZING AIR SYS,PADS A/B 14-0508 | 14-0509 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | AIR TO OTC CPVD GN2 STANDBY MODE AIR | TO GN2 132 CHANGEOVER OPTION B - GN2 | CHANGE 14-0515 | 18 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-0540 | | D3012 OMI RECORD IS NOT IN THE DATABASE 14-0549 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-0557 | 14-0560 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) 14-0574 | GN2 TO AIR CHANGEOVER 132 OPTION A | ORBITER SUPPORT 14-0576 | TERMINATION OF 232 ECS HAZARDOUS | PURGE GN2 OPERATIONS 14-0588 | CONTROL STATION 132 TRANSFER - | FIRING ROOM TO PAD 14-0596 | | S9001VL2 SHUTTLE POWER UP/POWER DOWN (LPS) 14-0610 | | V9001VL2 ORBITER POWER UP/POWER DOWN, DPS | OPTIONS (LPS) 14-0613 | | D3008 PURGE/PRESSURIZATION AND LOCKOUT | PROCEDURES FOR COMM ENCLOSURES 14-0620 | | V9018.001 MPS/SSME PREPS FOR PROPELLANT LOADING | (LPS) 14-0628 | | G3251 LH2 SYSTEM PREPS FOR VEHICLE LOADING | (LPS) 14-0629 | | G3151 LOX SYSTEM PREPS FOR VEHICLE LOADING 14-0633 | | T5401 H2 LEAK DETECTION EQUIPMENT | INSTALLATION (LD 54 AND LD 55) 14-0642 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-0643 | 14-0644 | | S9001VL2 SHUTTLE POWER UP/POWER DOWN (LPS) 14-0646 | | M3020 HIGH-PRESSURE GASEOUS HYDROGEN | FACILITY 14-0648 | | M3097 HIGH PURITY GASEOUS OXYGEN SYSTEM 14-0648 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-0667 | | V3538 MID-BODY UMBILICAL UNIT SUPPORT | OPERATIONS 14-0674 | 19 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-0677 | | V80-94500 DOOR 45, PRE-FLIGHT UMBILICAL PANEL | ACCESS, INSTALLATION 14-0681 | | V3538 MID-BODY UMBILICAL UNIT SUPPORT | OPERATIONS 14-0687 | | V3529 RSS PREPS FOR MATE/DEMATE 14-0691 | | M3097 HIGH PURITY GASEOUS OXYGEN SYSTEM 14-0725 | | M3083 MLP COMPOSITE STRUCTURE 14-0728 | | M3169 ORBITER WEATHER PROTECTION SYSTEM | OPERATION 14-0753 | | G3251 LH2 SYSTEM PREPS FOR VEHICLE LOADING | (LPS) 14-0762 | | V9001VL4 ORBITER POWER UP/POWER DOWN SSME | OPTIONS (LPS) 14-0771 | | V9018.001 MPS/SSME PREPS FOR PROPELLANT LOADING | (LPS) 14-0771 | | S9001VL1 SHUTTLE POWER UP/POWER DOWN (LPS) 14-0772 | | V2160 HYDRAULIC CHARGING UNIT (HCU) LPS | SUPPORT OPERATIONS 14-0804 | | V2153 ORBITER ACCESS ARM (OAA) LPS SUPPORT | OPERATION 14-0805 | | G2158 GOX VENT ARM LPS SUPPORT OPERATIONS - | (LPS) 14-0806 | | V9018.001 MPS/SSME PREPS FOR PROPELLANT LOADING | (LPS) 14-0818 | 14-0819 | | M3190 FIREX AND POTABLE WATER LAUNCH | COUNTDOWN OPERATIONS 14-0836 | | V3529 RSS PREPS FOR MATE/DEMATE 14-0853 | | V2160 HYDRAULIC CHARGING UNIT (HCU) LPS | SUPPORT OPERATIONS 14-0855 | | A2700 GROUND SUPPORT COMM SYS VALID 14-0859 | 14-0860 | | 20 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR M3006 HVAC SYS/PTCR/ECS ROOM, PAD A, C-39 14-0866 | | M3023 PTCR/ECS RM. HVAC SYS, PAD B 14-0866 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-0869 | | V2153 ORBITER ACCESS ARM (OAA) LPS SUPPORT | OPERATION 14-0871 | | M3094 ROTATION SERVICE STRUCTURE OPERATION 14-0873 | | V3517 LH2 TSM PREPARATION TO SUPPORT | INTEGRATED TEST 14-0878 | | V3518 LO2 TSM PREPARATION TO SUPPORT | INTEGRATED TEST 14-0879 | | V9018.001 MPS/SSME PREPS FOR PROPELLANT LOADING | (LPS) 14-0887 | | M3088 LOW-LEVEL OXYGEN ANALYZER UNITS | OPERATION 14-0896 | | G2158 GOX VENT ARM LPS SUPPORT OPERATIONS - | (LPS) 14-0901 | | T6446 EXTERNAL TANK (ET) PRE-CRYOLOAD/PAD | TPS INSPECTION 14-0919 | | V3518 LO2 TSM PREPARATION TO SUPPORT | INTEGRATED TEST 14-0927 | | V3517 LH2 TSM PREPARATION TO SUPPORT | INTEGRATED TEST 14-0928 | | M3054 GN2 ENVIR/CAMERA LENS PURGE SYS 14-0933 | | M3176 GN2 ENVIRON/CAM LENS PURGE SYS, PAD B 14-0933 | | M3190 FIREX AND POTABLE WATER LAUNCH | COUNTDOWN OPERATIONS 14-0933 | | D3008 PURGE/PRESSURIZATION AND LOCKOUT | PROCEDURES FOR COMM ENCLOSURES 14-0934 | | V3517 LH2 TSM PREPARATION TO SUPPORT | INTEGRATED TEST 14-0947 | | V3518 LO2 TSM PREPARATION TO SUPPORT | INTEGRATED TEST 14-0947 | | M3088 LOW-LEVEL OXYGEN ANALYZER UNITS | OPERATION 14-0961 | 21 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 14-0962 | | M3189.001 SOUND SUPPRESSION LAUNCH COUNTDOWN | OPERATIONS 14-0963 | | M3083 MLP COMPOSITE STRUCTURE 14-0980 | | M3134 PAD OPERATIONS, PADS A/B,C-39,KSC 14-0980 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 14-0998 | 14-1004 | 14-1005 | 14-1006 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | DOCK SEAL INFLATION DEFLATION, OTC | PPVM OPTION C 14-1025 | 14-1027 | | V2274 ORBITER/SRB ESP PLATFORM TRANSPORTER | OPERATIONS 14-1035 | 14-1039 | | M3189.001 SOUND SUPPRESSION LAUNCH COUNTDOWN | OPERATIONS 14-1043 | | M3169 ORBITER WEATHER PROTECTION SYSTEM | OPERATION 14-1046 | 14-1050 | 14-1053 | 14-1054 | | C3041 CCMS OPERATION SUPPORT PATCHING 14-1072 | | M3189.001 SOUND SUPPRESSION LAUNCH COUNTDOWN | OPERATIONS 14-1088 | 14-1094 | | V1117 COMMUNICATIONS LAUNCH CONFIGURATION | CHECKOUT (LPS) 14-1116 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-1118 | | S6444 SSV ICE AND DEBRIS ASSESSMENT 14-1128 | 14-1129 | | T6446 EXTERNAL TANK (ET) PRE-CRYOLOAD/PAD | TPS INSPECTION 14-1138 | | V1117 COMMUNICATIONS LAUNCH CONFIGURATION | CHECKOUT (LPS) 14-1141 | 22 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 14-1149 | 14-1164 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | DOCK SEAL INFLATION DEFLATION, OTC | PPVM OPTION C 14-1174 | | M3190 FIREX AND POTABLE WATER LAUNCH | COUNTDOWN OPERATIONS 14-1179 | | V5097.003 CREW SYSTEMS STOWAGE - FLIGHT | DECK/MIDDECK 14-1182 | | V66-90006 PLATFORM ACCESS SET, A70-0558 MIDDECK, | CREW MODULE VERTICAL, REMOVAL 14-1186 | | V66-50009 INSTALLATION/REMOVAL AIRLOCK OUT | VERTICAL ACCESS SET - CREW MODULE 14-1187 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 14-1232 | | S9001VL2 SHUTTLE POWER UP/POWER DOWN (LPS) 14-1236 | | G2158 GOX VENT ARM LPS SUPPORT OPERATIONS - | (LPS) 14-1254 | | M3197 HP GN2/GHE/COMP AIR/LPGN2 PREP, FRF 14-1266 | | G3251 LH2 SYSTEM PREPS FOR VEHICLE LOADING | (LPS) 14-1268 | 14-1277 | | M3190 FIREX AND POTABLE WATER LAUNCH | COUNTDOWN OPERATIONS 14-1311 | 14-1312 | | M3189.001 SOUND SUPPRESSION LAUNCH COUNTDOWN | OPERATIONS 14-1318 | | M3011 6K/3K/750-PSIG GN2 SYS PRESS/DEPRESS 14-1321 | 14-1321 | | M3054 GN2 ENVIR/CAMERA LENS PURGE SYS 14-1321 | | M3131 PAD/FSS/RSS GHE SYS PRESS/DEPRESS 14-1321 | | M3176 GN2 ENVIRON/CAM LENS PURGE SYS, PAD B 14-1321 | | M3197 HP GN2/GHE/COMP AIR/LPGN2 PREP, FRF 14-1321 | 14-1321 | 14-1321 | | 23 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR M3034 PRESSURIZING AIR SYS,PADS A/B 14-1326 | | V66-90002 EMERGENCY ALARMS AND LIGHTING, CREW | COMPARTMENT, REMOVAL 14-1329 | | G3151 LOX SYSTEM PREPS FOR VEHICLE LOADING 14-1331 | 14-1339 | | A2203.002 RSS MOVES TO PARK 14-1365 | 14-1366 | 14-1382 | 14-1391 | 14-1401 | 14-1403 | | Q3018 PRE-LAUNCH, POST-LAUNCH, POST-FRF | INSPECTION, ELEVATOR 14-1408 | | M3083 MLP COMPOSITE STRUCTURE 14-1415 | 14-1417 | 14-1418 | | M3088 LOW-LEVEL OXYGEN ANALYZER UNITS | OPERATION 14-1422 | 14-1423 | | M3175 OPERATION OF HOLDING TANK INDUSTRIAL | WASTEWATER SYSTEM 14-1426 | 14-1427 | | G2158 GOX VENT ARM LPS SUPPORT OPERATIONS - | (LPS) 14-1428 | 14-1429 | | M3083 MLP COMPOSITE STRUCTURE 14-1436 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | CONTROL STATION 132 TRANSFER - PAD | TO FIRING ROOM ,ECS PREPARATIONS FOR | AIR TO G 14-1438 | | A2203.002 RSS MOVES TO PARK 14-1439 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) 14-1440 | | V6C68 PREVENTIVE MAINTENANCE PAD A/B ECS | SYSTEM 14-1440 | | M3034 PRESSURIZING AIR SYS,PADS A/B 14-1453 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) 14-1459 | 24 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR | M3134 PAD OPERATIONS, PADS A/B,C-39,KSC 14-1463 | | D3008 PURGE/PRESSURIZATION AND LOCKOUT | PROCEDURES FOR COMM ENCLOSURES 14-1474 | | M3190 FIREX AND POTABLE WATER LAUNCH | COUNTDOWN OPERATIONS 14-1478 | | Q3018 PRE-LAUNCH, POST-LAUNCH, POST-FRF | INSPECTION, ELEVATOR 14-1479 | | M3189.001 SOUND SUPPRESSION LAUNCH COUNTDOWN | OPERATIONS 14-1484 | | G3251 LH2 SYSTEM PREPS FOR VEHICLE LOADING | (LPS) 14-1489 | 14-1492 | | Q3018 PRE-LAUNCH, POST-LAUNCH, POST-FRF | INSPECTION, ELEVATOR 15-0008 | | G3255 LH2 SYSTEM SCRUB-TURNAROUND 15-0016 | | M3022 COMPRESSED AIR SYSTEM 15-0019 | | S9001VL2 SHUTTLE POWER UP/POWER DOWN (LPS) 15-0020 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | PREPS FOR 132 AIR GN2 | CHANGEOVER,OPTION B - FINAL PREPS 15-0042 | | M3123 HPGHE/GN2/LPGN2 VALVE POSITIONING 15-0046 | | G3255 LH2 SYSTEM SCRUB-TURNAROUND 15-0047 | | M3034 PRESSURIZING AIR SYS,PADS A/B 15-0050 | | Q3018 PRE-LAUNCH, POST-LAUNCH, POST-FRF | INSPECTION, ELEVATOR 15-0056 | 15-0057 | | S9001VL2 SHUTTLE POWER UP/POWER DOWN (LPS) 15-0067 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 15-0068 | | M3006 HVAC SYS/PTCR/ECS ROOM, PAD A, C-39 15-0078 | | M3023 PTCR/ECS RM. HVAC SYS, PAD B 15-0078 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | 25 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR AIR 132 TO GN2 STANDBY MODE AIR TO | GN2 CHANGEOVER OPTION A - AIR TO GN2 | STANDBY 15-0102 | | S9001VL1 SHUTTLE POWER UP/POWER DOWN (LPS) 15-0150 | | V1117 COMMUNICATIONS LAUNCH CONFIGURATION | CHECKOUT (LPS) 15-0168 | | M3034 PRESSURIZING AIR SYS,PADS A/B 15-0173 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | AIR-TO-GN2 15-0180 | | G3251 LH2 SYSTEM PREPS FOR VEHICLE LOADING | (LPS) 15-0200 | | G3255 LH2 SYSTEM SCRUB-TURNAROUND 15-0201 | | G3151 LOX SYSTEM PREPS FOR VEHICLE LOADING 15-0223 | | G3155 LOX SYSTEM LAUNCH SCRUB/TURNAROUND 15-0223 | | G3251 LH2 SYSTEM PREPS FOR VEHICLE LOADING | (LPS) 15-0237 | | G3255 LH2 SYSTEM SCRUB-TURNAROUND 15-0238 | | S9002VL16 INTEGRATED DATA REQUIREMENTS FOR | S0007VL2, LAUNCH COUNTDOWN 15-0323 | | M3189.001 SOUND SUPPRESSION LAUNCH COUNTDOWN | OPERATIONS 15-0378 | | G2158 GOX VENT ARM LPS SUPPORT OPERATIONS - | (LPS) 15-0379 | | S1004 MPS LH2 SYSTEM AUTOMATIC LOAD AND | DRAIN OPERATIONS (LPS) 15-0383 | | S6444 SSV ICE AND DEBRIS ASSESSMENT 15-0386 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 15-0393 | | G2158 GOX VENT ARM LPS SUPPORT OPERATIONS - | (LPS) 15-0404 | 15-0405 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) 15-0410 | | S1003 MPS LOX SYSTEM AUTOMATIC LOAD AND | 26 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR DRAIN OPERATIONS 15-0416 | 15-0419 | 15-0425 | 15-0426 | | C2000 LCC CCMS OPERATION SUPPORT 15-0456 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 15-0468 | | G2158 GOX VENT ARM LPS SUPPORT OPERATIONS - | (LPS) 15-0528 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 15-0653 | | S6444 SSV ICE AND DEBRIS ASSESSMENT 16-0002 | | S1003 MPS LOX SYSTEM AUTOMATIC LOAD AND | DRAIN OPERATIONS 16-0011 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 16-0028 | 16-0029 | | C2000 LCC CCMS OPERATION SUPPORT 16-0134 | | S6444 SSV ICE AND DEBRIS ASSESSMENT 16-0171 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 16-0276 | 16-0277 | | S5018 INSERTION/REMOVAL OF SRB/SRSS AND | GSE/SRSS GROUND STATION FLT CODES 16-0284 | | V2160 HYDRAULIC CHARGING UNIT (HCU) LPS | SUPPORT OPERATIONS 16-0404 | | M3189.001 SOUND SUPPRESSION LAUNCH COUNTDOWN | OPERATIONS 16-0435 | | Z3111 MSBLS-GS MISSION SUPPORT - KSC 16-0479 | | C2000 LCC CCMS OPERATION SUPPORT 16-0495 | | S1004 MPS LH2 SYSTEM AUTOMATIC LOAD AND | DRAIN OPERATIONS (LPS) 16-0512 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 16-0532 | | S9002VL16 INTEGRATED DATA REQUIREMENTS FOR | S0007VL2, LAUNCH COUNTDOWN 16-0743 | 27 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 16-0828 | | V2160 HYDRAULIC CHARGING UNIT (HCU) LPS | SUPPORT OPERATIONS 16-0946 | | S9002VL16 INTEGRATED DATA REQUIREMENTS FOR | S0007VL2, LAUNCH COUNTDOWN 16-0994 | | S1004 MPS LH2 SYSTEM AUTOMATIC LOAD AND | DRAIN OPERATIONS (LPS) 16-1154 | 16-1156 | | M3190 FIREX AND POTABLE WATER LAUNCH | COUNTDOWN OPERATIONS 17-0019 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | GN2 TO AIR CHANGE OVER- 212 OPTION B | - POST LAUNCH OPERATIONS 17-0029 | | G3153 LOX SYSTEM SECURING AFTER LAUNCH (LPS) 17-0053 | | S1003 MPS LOX SYSTEM AUTOMATIC LOAD AND | DRAIN OPERATIONS 17-0055 | | M3190 FIREX AND POTABLE WATER LAUNCH | COUNTDOWN OPERATIONS 17-0086 | | V2153 ORBITER ACCESS ARM (OAA) LPS SUPPORT | OPERATION 17-0132 | | V2160 HYDRAULIC CHARGING UNIT (HCU) LPS | SUPPORT OPERATIONS 17-0132 | | G2158 GOX VENT ARM LPS SUPPORT OPERATIONS - | (LPS) 17-0134 | | S5018 INSERTION/REMOVAL OF SRB/SRSS AND | GSE/SRSS GROUND STATION FLT CODES 17-0136 | | S1004 MPS LH2 SYSTEM AUTOMATIC LOAD AND | DRAIN OPERATIONS (LPS) 17-0184 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 17-0198 | | M3189.001 SOUND SUPPRESSION LAUNCH COUNTDOWN | OPERATIONS 17-0209 | | Q3018 PRE-LAUNCH, POST-LAUNCH, POST-FRF | INSPECTION, ELEVATOR 17-0214 | | G3254 LH2 SYSTEM SECURING AFTER LAUNCH 17-0223 | | 28 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR M3022 COMPRESSED AIR SYSTEM 17-0251 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | TERMINATION OF ECS HAZ PURGE 132 GN2 | OPERATION. 17-0258 | | M3034 PRESSURIZING AIR SYS,PADS A/B 17-0261 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) 17-0262 | | M3097 HIGH PURITY GASEOUS OXYGEN SYSTEM 17-0286 | | M3020 HIGH-PRESSURE GASEOUS HYDROGEN | FACILITY 17-0287 | | V1122 PAD A/B ECS SUPPORT OPERATIONS (LPS | AND LPC) | MAIN BLOWER CHANGEOVER OPERATIONS | ,DOCK SEAL INSPECTION ECS SYSTEM | RELATIVE HUMI 17-0291 | | S6444 SSV ICE AND DEBRIS ASSESSMENT 17-0293 | | M3083 MLP COMPOSITE STRUCTURE 17-0304 | | M3088 LOW-LEVEL OXYGEN ANALYZER UNITS | OPERATION 17-0306 | | M3079 AC,VENTILATING,PRESSURIZING SYS,MLP 17-0310 | 17-0310 | 17-0310 | | G3254 LH2 SYSTEM SECURING AFTER LAUNCH 17-0318 | | T5448 ET GH2 VENT UMBLICAL RETRACT SYSTEM | ORDNANCE/GUCP REMOVAL 17-0323 | 17-0324 | | V1040.002 PRSD CRYO LOAD AND FUEL CELL | ACTIVATION 17-0327 | | S2005 POST LAUNCH SECURING 17-0349 | 17-0351 | | S9001VL1 SHUTTLE POWER UP/POWER DOWN (LPS) 18-0046 | 18-0047 | | V1123 GN&C COUNTDOWN AND MISSION SUPPORT | TESTING (LPS) 18-0089 | | S1003 MPS LOX SYSTEM AUTOMATIC LOAD AND | DRAIN OPERATIONS 19-0002 | 29 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR | S1004 MPS LH2 SYSTEM AUTOMATIC LOAD AND | DRAIN OPERATIONS (LPS) 19-0002 | | V1040.003 FUEL CELL PRSD LAUNCH | HOLD/RECYCLE/SCRUB CONTINGENCY | OPERATIONS 19-0061 | | G2158 GOX VENT ARM LPS SUPPORT OPERATIONS - | (LPS) 21-0002 | | M3189.001 SOUND SUPPRESSION LAUNCH COUNTDOWN | OPERATIONS 22-0020 | 22-0022 | 30 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- | B42AP0.050-B APU BITE TEST (POST N2H4 LD TO L-24 HR) 14-0409 _____| (1R ) L02 B056-999 | | B42AP0.050-C APU BITE TEST (T-9 HR) 15-0257 _____| (1R ) L02 B056-999 | | B42AP0.060-B APU FREQ BITE (POST N2H4 LD TO L-24 HR) 14-0409 _____| (1 ) L02 B056-999 | | B42AP0.060-C APU FREQ BITE TEST (T-9 HR) 15-0257 _____| (1 ) L02 B056-999 | | B42AP0.080-A BEARING SOAK (POST N2H4 LD TO L-24 HR) 14-0410 _____| (1R ) L02 B056-999 | | B42AP0.080-B BEARING SOAK (T-9 HR) 15-0257 _____| (1R ) L02 B056-999 | | GLUGGDMF0.004 HUMS GAS ANALYSIS MLP-3 15-0250 _____| GOTBU (MLP-3) | | GLVGGDMF0.004 HUMS GAS ANALYSIS MLP-2 15-0250 _____| GOTBU (MLP-2) | | GLWGGDMF0.004 HUMS GAS ANALYSIS MLP-1 15-0250 _____| GOTBU (MLP-1) | | GRVFEVRA1.005 PAD A FSS ELEVATOR#1 OPERATIONAL CHECK 15-0009 _____| (1 ) GFF1-90 | | GRVFEVRA2.005 PAD A FSS ELEVATOR#2 OPERATIONAL CHECK 15-0009 _____| (1 ) GFF1-90 | | GRXFEVRC0.005 PAD B FSS ELEVATOR#1 OPERATIONAL CHECK 15-0009 _____| (1 ) GFF1-90 | 31 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- GRXFEVRD0.005 PAD B FSS ELEVATOR#2 OPERATIONAL CHECK 15-0009 _____| (1 ) GFF1-90 | | G51FGDMA0.060 HGDS - SYSTEM GAS ANALYSIS 15-0250 _____| GOTBU | | G51FGDMA0.095 B/U HGDS-SYSTEM GAS ANALYSIS 15-0250 _____| GOTBU | | G51FG0000.104 VERIFY VENT SEALS SUPPORT TANKING 15-0528 _____| GOA;C | | G61FGDMA0.060 HGDS - SYSTEM GAS ANALYSIS 15-0250 _____| GOTBU | | G61FGDMA0.095 B/U HGDS-SYSTEM GAS ANALYSIS 15-0250 _____| GOTBU | | G61FG0000.104 VERIFY VENT SEALS SUPPORT TANKING 15-0528 _____| GOA;C | | P018JB.035-C QUIET TIME - LAUNCH COUNTDOWN 14-1228 _____| PIUS | V04F10 15-0169 _____| | 16-0118 _____| | P018JC.010 LAUNCH COUNTDOWN - IUS RQMTS. 15-0169 _____| PAXAF | 16-0692 _____| | 16-1039 _____| | 16-1078 _____| | 16-1079 _____| 32 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- P095DB.030 PRELAUNCH ACTIVE COOLING 14-0611 _____| PSHM;C | | P095PR.893 MODULE COOLING - LAUNCH 16-0318 _____| PSHM;C | | S00E00.A00 RECONNECT GSE PWR 18-0061 _____| VAF;C | | S00E00.B40 PFM/VFY DE-ARMING OF SSW CMD BUS 19-0036 _____| (1 ) VAF;C | | S00E00.B50 SECURE SSW SYSTEM 19-0044 _____| (1 ) VAF;C (SLPG2) | | S00E00.B60 VERIFY/ACTIVATE SSME FIRE DETECTORS 19-0044 _____| (1 ) VAF;C (SLPG2) | | S00E00.B70 DISARM H2 BURN SYSTEM 19-0044 _____| VAF;C (SLPG2) | | S00E00.B80 RE-EXTEND & LOCK OAA/CCAA 19-0044 _____| VAF;C (SLPG2) | | S00E00.B85 LO2 SAFING AFTER TERM COUNT BREAKOUT 19-0044 _____| VAF;C (SLPG2) | | S00E00.B90 ANTI GEYSER RQMTS AFTER ENG SHUTDOWN 16-1154 _____| (1 ) VAF;C | 16-1154 _____| | 16-1156 _____| | 16-1156 _____| | 19-0044 _____| (SLPG2) | 33 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00E00.B95 LH2 TOPPING LINE DRAIN BACK 16-1154 _____| (1 ) VAF;C | 16-1154 _____| | 16-1156 _____| | S00E00.012 GH2 REDLINES 21-0001 _____| (1 ) SAF;C | | S00E00.050 PVD RECYCLE CONFIGURATION 19-0044 _____| VAF;C (SLPG2) | | S00E00.070 SSME SHUTDN VERIFICATION 19-0044 _____| (1 ) VAF;C (SLPG2) | | S00E00.130 PERFORM/VERIFY LH2 TANK VENTING 16-1154 _____| (1 ) TAF;C | 16-1156 _____| | S00E00.137 HEAT SHIELD WATER ACT. POST ABORT 16-1154 _____| (1 ) VAF;C | 16-1156 _____| | S00E00.150 INITIATE/VERIFY SSME PURGE SEQ 3 19-0044 _____| (1R ) VAF;C (SLPG2) | | S00E00.160 INITIATE/VERIFY SSME GN2 PURGE 19-0025 _____| (1 ) L03 V02FR12;C | V03FR15;C 19-0044 _____| V04FR11;C (SLPG2) | V05F;C | | S00E00.161 ACTIVATE SSME GN2 PURGE HEATER POWER 19-0026 _____| (1 ) L02 V02FR12;C | V03FR12;C | V04FR8;C | V05F;C | 34 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00E00.205 PERFORM/VERIFY LH2 PREVLS CLOSED 19-0044 _____| (1 ) VAF;C (SLPG2) | | S00E00.305 ACTIVATE/VERIFY SSME MFVA HTR PWR ON 19-0044 _____| VAF;C (SLPG2) | | S00E00.460 TERMINATE ET LO2 PRE-PRESS 19-0044 _____| VAF;C (SLPG2) | | S00E00.490 VERIFY ET INTERTANK COMPARTMENT TEMP 21-0003 _____| (1 ) TAF;C | | S00E00.540 MAINTAIN ET LH2 ULLAGE PRESS 21-0003 _____| (1 ) L02 TCN54-999;C | | S00E00.660 SECURE OMS 19-0034 _____| VAF;C | | S00E00.670 PRSD TRANSFER TO EXTERNAL REACTANTS 19-0062 _____| VAF;C | | S00E00.710 VERIFY APU'S SHUTDOWN 19-0012 _____| (1R ) VAF;C | | S00E00.720 HPU SHUTDOWN SEQ (PRE AFT MDM LOCKOUT) 19-0044 _____| BAF;C (SLPG2) | | S00E00.721-A HPU SHUTDOWN SEQ (A, B, C, D) 19-0044 _____| (1 ) BAF;C (SLPG2,S) | | S00E00.721-B FUEL ISOLATION VALVE CYCLE (E) 20-0038 _____| (1 ) BAF;C | | S00E00.740 ENABLE RSRM JOINT HEATER SYSTEM 20-0008 _____| L01 BCN097-098;C | ENABLE RSRM JOINT HEATER SYSTEM | L02 BCN099-999;C | 35 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00E00.742 ENABLE RSRM IGNITER HEATER SYSTEM 20-0008 _____| L01 BCN097-098;C | ENABLE RSRM IGNITER HEATER SYSTEM | L02 BCN099-999;C 28-015 _____| | S00E00.750 SRM IGNITER S&A SAFING 19-0044 _____| (1 ) BAF;C (SLPG2) | | S00E00.751 SRB RSS S&A SAFING 19-0044 _____| (1 ) BAF;C (SLPG2) | | S00E00.760 SRB RSS INHIBIT RESET FOR RECYCLE 19-0044 _____| (1R ) BAF;C (SLPG2) | | S00E00.790 INHIB LCA PIC FIRE CMDS FOR RECYCL 19-0044 _____| (1R ) VAF;C (SLPG2) | | S00E00.800 SRM PIC CAP DISCHARGED VERIF 19-0044 _____| (1R ) BAF;C (SLPG2) | | S00E00.810 ET VENT ARM PIC CAPS DISCHARGED 19-0044 _____| (1R ) SAF;C (SLPG2) | | S00E00.811 ORB OEX/MADS DEACTIVATION 23-0003 _____| VAF;C | 28-011 _____| | S00E00.820 T-0 UMB PIC CAPS DISCHARGED 19-0044 _____| (1R ) SAF;C (SLPG2) | | S00E00.830 SRB HOLDDOWN PIC CAPS DISCHARGED 19-0044 _____| (1R ) SAF;C (SLPG2) | | S00E00.840 ACT HYD CIRC PUMPS FOR SSME WARM FLOW 18-0014 _____| (1R ) VAF;C | 36 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00E00.870 REACTIVATE GROUND COOLING FLOW 19-0044 _____| (1R ) VAF;C (SLPG2) | | S00E00.880-A CONFIGURE PASS FOR PRELAUNCH 18-0041 _____| (1R ) VAF;C | | S00E00.880-B CONFIGURE BFS FOR PRELAUNCH 18-0041 _____| (1R ) VAF;C | | S00E00.890 IMU TO GYROCOMPASS MODE 18-0089 _____| (1R ) VAF;C | | S00E00.894 ACTR INITIALIZATION MODE 1 19-0020 _____| (1R ) SAF;C | | S00E00.915 BFS ONE SHOT DATA XFER 18-0101 _____| (1R ) VAF;C | | S00E00.920 ONBOARD C/D CLOCK STOPPED VERIF 28-002 _____| (1 ) VAF;C | | S00E00.930 SRB FWD MDM'S UNLOCK 19-0044 _____| (1R ) BAF;C (SLPG2) | | S00E00.940 ONBD C/D CLOCK RECYCLED & STOPPED 19-0044 _____| (1 ) VAF;C (SLPG2) | | S00E00.950 SRB AFT MDM'S UNLOCK 19-0044 _____| (1R ) BAF;C (SLPG2) | | S00E00.960 VERIFICATION OF ORBITER GMTLO 16-0958 _____| (1 ) VAF;C | 37 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00E00.970 OPS RECORDER TERMINATION 23-0006 _____| VAF;C | 28-011 _____| | S00E00.975 P/L RECORD TERMINATION 23-0009 _____| VAF;C | 23-0019 _____| | 28-012 _____| | S00E00.980 CMD DCDRS POWER ACTIVATION 19-0044 _____| (1R ) VAF;C (SLPG2) | | S00E00.991 ET BIPOD HTRS REACTIVATION 18-0069 _____| TAF;C | | S00FA0.014 LPS VENT DOORS OVERRIDE WORD 16-0809 _____| V02F12-90 | V03F18-90 | V04F13-90 | V05F1-90 | | S00FA0.015 PIC RESISTANCE TEST (GO MODE) 16-0088 _____| (1 ) L01 V02F25 | V03F24 | V05F13 | PIC RESISTANCE TEST (GO MODE) | L02 V02F26-90 | V03F25-90 | V04F21-90 | V05F14-90 | | S00FA0.116 ET LO2 LOW RANGE ULLAGE PRESS XDCR CK 15-0417 _____| (1 ) L02 T90-999 | 38 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FA0.120 LO2 VENT/RELIEF VLV ACTUATION LINE PGE 15-0417 _____| (1 ) TAF1-999 | | S00FA0.130 LH2 VENT/RELIEF VLV ACTUATION LINE PGE 14-0627 _____| (1 ) TAF1-999 | | S00FA0.141 VERIFY ET LO2 LOW RANGE PRESSURES 15-0417 _____| (1 ) L02 T45,49,51,54-999 | | S00FA0.213-A PERFORM AND VERIFY SSMEC POWER ON 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | | S00FA0.213-B LOAD CONTROLLER MEMORY 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | 39 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FA0.213-C EXECUTE SENSOR AND SPARK IGNITER C/O 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | | S00FA0.213-D EXECUTE COMMANDED CONTROLLER CHECKOUT 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | | S00FA0.213-E EXECUTE PNEU COMPONENT CHECKOUT 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | | S00FA0.213-F VERIFY SSME FLIGHT ACTIVE 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | | S00FA0.213-G ISSUE SSME PSN 3 COMMAND (REF. C-6) 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | 40 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FA0.213-H ISSUE SSME CONT RESET CMD 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | | S00FA0.213-I ISSUE SSME PSN1 COMMAND (REF. R-1) 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | | S00FA0.213-J VERIFY ACTUATOR COMMAND/POSITION 14-0893 _____| (1 ) L02 V02F25-90 | V03F24-90 | V04F21-90 | V05F12-90 | | S00FA0.225 PERF/VFY INIT LH2 ORB/ET DISC CAV PURG 15-0083 _____| L02 V02F22-90 | V03F22-90 15-0595 _____| V04F18-90 | V05F12-90 | | S00FA0.301 LOAD/VFY FINAL PCM AND PDI FORMATS 14-0104 _____| (1R ) VAF1-90 | | S00FA0.365 VFY FUEL CELL INSTRUMENTATION (PNL F9) 16-0311 _____| (1R ) VAF1-90 | | S00FA0.370-A COMSEC 1 LOAD VERIFICATION 14-0127 _____| (1R ) VAF1-90 | | S00FA0.370-B COMSEC 2 LOAD VERIFICATION 14-0127 _____| (1R ) VAF1-90 | 41 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FA0.372-A S-BAND PM STRING 1 STDN HI 15-0355 _____| VAF1-90 | | S00FA0.372-C AUDIO CENTER 1 & 2 VERIFICATION 14-1156 _____| VAF1-90 | | S00FA0.372-D COMSEC 1 & 2 OPERATION 15-0355 _____| VAF1-90 | | S00FA0.372-E FM 1 & 2 OPERATION 14-1156 _____| VAF1-90 | | S00FA0.372-F UHF OPERATION 14-1156 _____| VAF1-90 | | S00FA0.372-H S-BAND PM STRING 1 MODES 15-0355 _____| VAF1-90 | | S00FA0.372-I TRANSMIT P/L INTRG SWEEP WIDE CMD 15-0355 _____| VAF1-90 | | S00FA0.435 HGDS OPERAT DURING TANKING/DETANK 15-0250 _____| VAF1-90 | 16-0007 _____| | S00FA0.510 RSS STATUS CHECK 15-0463 _____| (1 ) L03 B082-999 | | S00FA0.600 RSRM PMBT 15-0388 _____| (1 ) B025,027-999;C | | S00FA0.610 RSRM SEGMENT JOINT HEATER SYSTEM 15-0216 _____| (1R ) L01 B042-098 | RSRM SEGMENT JOINT HEATER SYSTEM | L02 B099-999 | 42 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FA0.620 RSRM IGNITER HEATER SYSTEM 14-1098 _____| (1R ) L02 B073-098 | RSRM IGNITER HEATER SYSTEM | L03 B099-999 15-0217 _____| | 28-015 _____| | S00FA0.630 VERIFY SRB SRGA BACKUP PWR SOURCE 15-0074 _____| VAF1-90 | | S00FA0.770 FLT CNTL SRB TVC POWER UP 15-0277 _____| VAF1-90 | | S00FA0.776 RSRM NOZZLE FLEX BEARING TEMP LIMIT 16-0022 _____| (1 ) L04 B068-999 | | S00FA0.777 RSRM NOZZLE TO CASE TEMPERATURE LIMIT 16-0022 _____| (1R ) L02 B062-999 | | S00FA0.810-A LO2 17-INCH DISC AND LATCH POSITIONING 14-1340 _____| VAF1-90 | | S00FA0.810-B LH2 17-INCH DISC AND LATCH POSITIONING 14-1278 _____| VAF1-90 | | S00FA0.820 VERIFY CREW ESC ROUTE TEMP/H2 SENSORS 15-0354 _____| SAF1-999 | | S00FA0.850 SRB T-0 UMBILICAL PURGE 14-0991 _____| B038-039,042-999 | | S00FA0.870 SOUND SUPPRESSION SYS INSP - WATER BAGS 14-1477 _____| V02F11-90 | V03F11-90 | V04F7-90 | V05F1-90 | 43 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FA0.900 PRELAUNCH WEATHER BRIEFING (L-1 DAY) 14-1128 _____| VAF1-90 | | S00FA0.940 PITCH/ROLL/YAW CSS MODE COMMAND CHK 14-0272 _____| (1R ) VAF1-90 | | S00FA0.960 RSRM IGNITER HEATER SYS CURRENT VERIF 14-1098 _____| B025,027,028 | B032-999 15-0217 _____| | 20-0008 _____| | S00FA0.970 RSRM FLD JNT HEATER SYS CURRENT VERIF 15-0216 _____| B025,027,028 | B032-999 20-0008 _____| | S00FA0.980 DEACTIVATE RSRM IGNITER HEATER SYSTEM 16-1076 _____| B030-999 | 28-027 _____| | S00FB0.005 ET TPS SURFACE MONITORING 17-0145 _____| (1 ) T23,27-29,31-999 | | S00FB0.011 CLOSEOUT AIR SAMPLE 16-0299 _____| VAF1-90 | | S00FB0.050 VFY ORB FWD/PLB/AFT PURGED WITH GN2 16-0009 _____| (1 ) L02 V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | 44 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FB0.070 VFY MPS HE SYS CONFIG 15-0595 _____| (1R ) VAF1-90 | | S00FB0.080 MPS HELIUM SYSTEM ACTIVATION 15-0595 _____| (1R ) VAF1-90 | | S00FB0.082 SSME REG MONITORING REQUIREMENTS 15-0595 _____| (1R ) L02 V02F23-90 | V03F23-90 | V04F20-90 | V05F12-90 | | S00FB0.083 PNEU REG MONITORING REQUIREMENTS 15-0595 _____| VAF1-90 | | S00FB0.090-A MPS LO2 VLV PRELOADING CONFIGURATION 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FB0.090-B MPS LH2 VLV PRELOADING CONFIGURATION 15-0595 _____| (1 ) VAF1-90 | | S00FB0.230 VERIFY ORB/LPS LDB REDUNDANCY 15-0335 _____| (1R ) L03 V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | S00FB0.281-A S-BAND PM STRING 2 STDN HI 15-0355 _____| (1R ) VAF1-90 | | S00FB0.281-B S-BAND PM STRING 2 MODES 15-0355 _____| (1R ) VAF1-90 | | S00FB0.281-C FRAME SYNC THRESHOLD COMPARE 15-0355 _____| (1R ) VAF1-90 | | S00FB0.281-D AGC LCC VERIFICATION 15-0355 _____| 45 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- (1R ) VAF1-90 | 46 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FB0.290 INITIATE ET INTERTANK PURGE 15-0595 _____| (1 ) T37-999 | | S00FB0.300 PERFORM/VERIFY SSME OXID PURGE 17-0055 _____| (1 ) L02 V02F12-90 | V03F15-90 21-0007 _____| V04F11-90 | V05F1-90 | | S00FB0.310 ISSUE SSME PURGE SEQ NO. 2 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FB0.320 ISSUE SSME PURGE SEQ NO. 3 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FB0.330 INITIATE ET NOSE CONE PURGE & CONTROL 15-0417 _____| (1 ) L04 T64-999;C | | S00FB0.340 MPS LO2 PREVLV OPEN RESPONSE TIME 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FB0.350 MONITOR GO2 VENT HOOD 17-0145 _____| (1 ) VAF1-90 | | S00FB0.360 MONITOR ET/ORB MPS FOR LEAKAGE 17-0145 _____| (1 ) VAF1-90 | | S00FB0.370 VFY RSS/RCVY BATTERY AMP-HR 15-0572 _____| L02 B082-999 | 20-0014 _____| 47 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FC0.070 PFM HYD SYS CONFIG FOR CRYO LOAD 15-0022 _____| (1R ) L04 V02F17-90 | V03F19-90 | V04F13-90 | V05F7-90 | | S00FC0.072 PFM LDG GR SYS FINAL FILL 15-0023 _____| (1R ) L03 V02F12-90 | V03F15-90 | V04F13-90 | V05F2-90 | | S00FC0.080 INITIATE LO2 ORB/ET DISCONNECT PURGE 17-0055 _____| (1 ) L02 V02F17-90 | V03F19-90 21-0007 _____| V04F13-90 | V05F7-90 | | S00FC0.090 INSTL GO2 VENT HOOD & INITIATE PURGE 15-0406 _____| (1 ) VAF1-90 | | S00FC0.100 VERIFY LO2 T-O UMB PURGE 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FC0.120 LO2 PRE-PRESS ANTI-ICING PURGE 17-0055 _____| (1 ) VAF1-90;C | 21-0007 _____| | S00FD0.062 PERFORM ORB/ET LO2 CHILLDOWN 17-0055 _____| (1 ) L03 T90-999 | 21-0007 _____| | S00FD0.073 PERFORM LO2 SLOW FILL 17-0055 _____| (1 ) L03 T90-999 | 21-0007 _____| | S00FD0.094 PERFORM LO2 FAST FILL FROM 2 TO 98 PCT 17-0055 _____| 48 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- (1 ) L06 T96-999 | PERFORM LO2 FAST FILL FROM 2 TO 98 PCT | L07 T90-95 21-0007 _____| 49 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FD0.095-A TURN SSME GN2 HEATER OFF 17-0055 _____| VAF1-90 | 21-0007 _____| | S00FD0.095-B SSME GN2 PURGE TEMPERATURE 16-1127 _____| VAF1-90 | | S00FD0.121-A MPS LO2 ECO SENSORS IND WET 17-0055 _____| (1R ) VAF1-90 | 21-0007 _____| | S00FD0.121-B MPS LH2 LOW LVL SENSORS IND WET 16-0035 _____| (1R ) VAF1-90 | | S00FE0.020 ACTIVATE LH2 T-0 UMB PLATE HE PURGE 15-0083 _____| (1 ) VAF1-90 | | S00FE0.040 ACTIVATE TSM AND TUNNEL PURGES 15-0595 _____| (1 ) VAF1-90 | | S00FE0.050 VFY ET GUCP LH2 VENT DISC CAVITY PURGE 15-0595 _____| (1 ) L02 T68-999 | | S00FE0.100 INITIATE LH2 PREPRESS ANTI-ICING PURGE 16-0035 _____| (1 ) VAF1-90;C | | S00FE0.111 ORB MPS LH2 CHILLDOWN & FILL TO 5% 16-0035 _____| (1 ) L02 T45,48-51,54-95 | ORB MPS LH2 CHILLDOWN & FILL TO 5% | L03 T96-999 | 50 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FE0.185 SRB MDM PRELAUNCH VERIF 16-0519 _____| (1R ) L02 V02F18-90 | V03F20-90 | V04F14-90 | V05F9-90 | | S00FE0.190 PRELAUNCH MDM DISCRETES OUTPUT VERIF 16-0149 _____| (1R ) VAF1-90 (VAS94) | | S00FE0.210 ACTR INITIALIZATION MODE 1 16-0266 _____| VAF1-90 | | S00FE0.225-A MDM LL1 POWER SEPARATION 16-0519 _____| (1R ) B075-999 | | S00FE0.225-B MDM LR1 POWER SEPARATION 16-0519 _____| (1R ) B075-999 | 51 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FE0.230-A MDM LL2 POWER SEPARATION 16-0519 _____| (1R ) L02 B070-999 | | S00FE0.230-B MDM LR2 POWER SEPARATION 16-0519 _____| (1R ) L02 B070-999 | | S00FE0.240 SRB DFI & SRBTS POWER UP 16-0346 _____| (1 ) B032,034,036,039 | B040,042-999 | | S00FF0.011 PERFORM LH2 FAST FILL TO 85 PERCENT 16-0073 _____| (1 ) L02 V02F12-90 | V03F15-90 | V04F12-90 | V05F2-90 | | S00FF0.030 LH2 RECIRC PUMP ACTIVATION/PREVLV CLOSE 16-0073 _____| (1 ) L02 V02F15-90 | V03F17-90 | V04F13-90 | V05F4-90 | | S00FF0.070 PRESSURIZE MPS HE TANKS TO FLT PRESS 15-0083 _____| (1 ) VAF1-90 | | S00FF0.081 PERFORM LH2 REDUCED FAST FILL TO 98 PCT 16-0073 _____| (1 ) L02 V02F12-90 | V03F15-90 | V04F12-90 | V05F1-90 | | S00FF0.082 PERFORM LH2 TOPPING TO 100 PCT 16-0131 _____| (1 ) VAF1-90 | | S00FF0.091 PERFORM LH2 REPLENISH FLOW AT 100 PCT 16-0133 _____| (1 ) VAF1-90 | 52 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FF0.095 PERFORM/VERIFY ET BIPOD HTRS PWR ON 16-0078 _____| L03 T43,45,48-51 | T54-999 | | S00FF0.101 PFM LO2 TOPPING (FROM 98 TO 100 PCT) 17-0055 _____| (1 ) L05 T90-999 | 21-0007 _____| | S00FF0.145 PERFORM LO2 REPLENISH FLOW AT 100 PCT 17-0055 _____| (1 ) L05 T90-999 | 21-0007 _____| | S00FF0.170 SRB HPU GAS GENERATOR BED HEATERS 16-0581 _____| SAF1-999 | 16-0876 _____| (SGPW2) | | S00FF0.190 CLOSE LH2 INBD FILL & DRAIN VLV 16-0073 _____| (1 ) VAF1-90 | | S00FF0.204 LO2 & LH2 LIQ LVL SENSOR CONT VFY 16-0544 _____| (1R ) VAF1-90 | | S00FF0.215 SRB RATE GYRO POWER ACTIVATION 16-0440 _____| (1R ) L03 V02F18-90 | V03F21-90 | V04F14-90 | V05F9-90 | | S00FF0.230 SRB RGA TORQUE TEST 16-0441 _____| (1R ) SAF1-999 | | S00FF0.235 VERIFY/ARM RCS DRIVERS 16-0562 _____| (1R ) VAF1-90 | 53 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FF0.250-A MCCH TRANSMIT DAY OF LAUNCH I-LOAD 16-0666 _____| VAF;C | | S00FF0.250-B PERFORM DOWNLIST DUMP OF PASS GPC PITCH 16-0682 _____| VAF;C | | S00FG0.050 PERFORM MCC AIR-TO-GND VOICE CHECK 16-0638 _____| (1R ) VAF1-90 | | S00FG0.085 GPC - MTU CHAN 1 GMT/MET UPDATE 16-0565 _____| VAF1-90 | | S00FH0.031 ACTIVATE AND VFY RANGE SAFETY SYS 16-0759 _____| (1 ) L05 B082-999 | | S00FJ0.015 WSB N2 SUPPLY CONFIGURE FOR LAUNCH 16-0827 _____| V02F17-90 | V03F19-90 | V04F13-90 | V05F7-90 | | S00FK0.025-A TRANSITION REDUNDANT SET TO FLT 16-0953 _____| (1R ) VAF1-90 | | S00FK0.025-B DUMP AND VERIFY OPS-1 LOAD FROM 16-1013 _____| (1R ) VAF1-90 | | S00FK0.030 CONFIGURE BFS GPC FOR FLIGHT 16-0966 _____| (1R ) VAF1-90 | | S00FK0.050-A MPS LO2 VLVS PWR "ON" VERIF 16-0976 _____| (1R ) V02F25,26 | V03F24 | V05F13 | 54 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FK0.050-B MPS LH2 VLVS PWR "ON" VERIF 16-0975 _____| (1R ) V02F25,26 | V03F24 | V05F13 | | S00FK0.080 MPS HE ISO VLV XFER CONTROL TO ORB 16-0974 _____| (1 ) VAF1-90 | | S00FM0.020 GMT, GMTLO AND CDT SYNCHRONIZATION 16-0876 _____| (1 ) VAF1-90 (SLP07) | | S00FM0.040 DEACTIVATE SSME MFVA HTR PWR 16-0876 _____| VAF1-90 (SGPT2) | | 16-1121 _____| | S00FM0.043 TERMINATE LO2 REPLENISH 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FM0.050 CLOSE LO2 INBD FILL AND DRAIN VALVE 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FM0.060 INITIATE LO2 TSM DRAIN 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FM0.110 SPBK & RUDDER GRAVITY POS 14-1015 _____| (1R ) VAF1-90 (SWB02) | | S00FM0.175 PERFORM HYD SYS APU-POST START 16-1106 _____| (1R ) VAF1-90 | | S00FM0.210 ARM SRB S&A DEVICES 16-0876 _____| (1 ) SAF1-999 (SGPT2) | 55 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FM0.250 ISSUE SSME PURGE SEQ NO. 4 16-0876 _____| (1 ) VAF1-90 (SGPT2) | | S00FM0.270 AEROSURFACE PROFILE 16-0876 _____| (1 ) VAF1-90 (SSPS1) | | S00FM0.280 BODY FLAP & SPBK LAUNCH POS 16-0876 _____| (1 ) VAF1-90 (SGPU2) | | S00FM0.290 BODY FLAP COMMAND OUTPUTS 16-0876 _____| (1R ) VAF1-90 (SGPU2) | | S00FM0.300 MPS GIMBAL PROFILE CHECK 16-0876 _____| (1R ) VAF1-90 (SSPS1) | | S00FM0.310 MPS ENGINES TO START POSITION 16-0876 _____| (1 ) VAF1-90 (SGPU2) | | S00FM0.321 TERMINATE ET HELIUM INJECT FLOW 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FM0.330 TERMINATE LO2 PREPRESS ANTI-ICING PURGE 17-0055 _____| VAF1-90 | 21-0007 _____| | S00FM0.342 CLOSE LO2 VENT VLV & PREPRESS TANK 17-0055 _____| (1 ) L04 T90-999 | 21-0007 _____| | S00FM0.350 PERFORM/VERIFY SSME GN2 PURGE OFF 16-0876 _____| (1 ) VAF1-90 (SGPU2) | | 16-1126 _____| 56 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FM0.360 TERMINATE GO2 VENT HOOD PURGE 16-0876 _____| VAF1-90 (SLPJ0) | | S00FM0.370 RETRACT GO2 VENT HOOD 16-0876 _____| (1 ) VAF1-90 (SLPJ0) | | S00FM0.380 TERMINATE LH2 TANK REPLENISH 16-1136 _____| (1 ) VAF1-90 (SSH03) | | S00FM0.390 TERM LH2 PREPRESS ANTI-ICING PURGE 16-1136 _____| VAF1-90 (SSH03) | | S00FM0.400 CL ET LH2 VENT VLV & INIT PRE-PRESS 16-1136 _____| (1 ) L02 T92-999 (SSH03) | | S00FM0.430 SRB AFT SKIRT INERTING PURGE 16-0986 _____| (1 ) B025,027-999 | | S00FM0.440 TERMINATE NOSE CONE PURGE 17-0055 _____| (1 ) VAF1-90 | 21-0007 _____| | S00FM0.450 TERMINATE ET INTERTANK PURGE 16-1136 _____| (1 ) L02 V02F18-90 (SSH03) | V03F22-90 | V04F15-90 | V05F10-90 | | S00FN0.040 PERFORM SRB FWD MDM LOCKOUT 16-0876 _____| (1R ) B052-999 (SGPW2) | 57 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FN0.825 DEACTIVATE RSRM JOINT HEATER SYSTEM 16-0876 _____| B031-999 (SGPW2) | | S00FN0.840 INTG VEHICLE GSE PWR REMOVAL 16-0876 _____| (1 ) V02F15-90 (SGPW2) | V03F18-90 | V04F13-90 | V05F5-90 | | S00FP0.030 ET BIPOD HEATERS OFF 16-0876 _____| (1 ) L02 V02F15-90 (SGPW2) | V03F17-90 | V04F13-90 | V05F5-90 | | S00FP0.050 CLOSE MPS LO2/LH2 OUTBD F/D VLVS 16-0876 _____| (1 ) VAF1-90 (SGPW2) | | S00FP0.060 INTG VEH GSE PWR OFF CMD REMOVAL VER 16-0876 _____| (1 ) V02F15-90 (SGPW2) | V03F18-90 | V04F13-90 | V05F5-90 | | S00FR0.010 REDUNDANT SET AUTO SEQ START 16-0876 _____| VAF1-90 (SGPW2) | | S00FR0.070 START SRB HPU 16-0876 _____| (1 ) L02 B038-999 (SGPW2) | | S00FS0.020 PERFORM GROUND COOLING SHUTDOWN 16-0876 _____| VAF1-90 (SLP26) | | S00FS0.030 SRB GIMBAL TEST 16-0876 _____| (1 ) SAF1-999 (SSPS1) | | S00FS0.080 ORDNANCE ARMED VERIFICATION 16-0876 _____| (1R ) VAF1-90 (SLP26) | 58 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- | S00FS0.090 PERFORM SRB AFT MDM LOCKOUT 16-0876 _____| (1R ) L02 B052-999 (SLP26) | 59 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00FT0.020 REMOVE RSS INHIBITS 16-0876 _____| (1R ) SAF1-999 (SLP26) | | S00FT0.040 TERMINATE MPS HE TANK FILL 16-0876 _____| (1 ) VAF1-90 (SLP26) | | S00FT0.050 DEACTIVATE MPS LH2 RECIRC SYS 16-0876 _____| (1 ) VAF1-90 (SLP26) | | S00FT0.100 LPS ISSUE GO FOR SSME START 16-0876 _____| VAF1-90 (SLP26) | | S00FT0.110 ACTIVATE SSME FREE H2 BURN SYSTEM 16-0876 _____| VAF1-90 (SLP26) | | S00FT0.120 ACTIVATE SOUND SUPPRESSION WATER 16-0876 _____| VAF1-90 (SLP26) | | S00L00.030 ET TANKING WIND VELOCITY LIMIT (KSC) 15-0210 _____| (1 ) SAF1-999 | | S00L00.051-A LH2 TANK PRESSURE (WIND CONDITION) 14-0654 _____| (1 ) L02 T43,45,48-51 | T54-999 14-1269 _____| | S00L00.051-B LO2 TANK PRESSURE (WIND CONDITION) 15-0417 _____| (1 ) L02 T43,45,48-51 | T54-999 | | S00L00.080 ET PROP LOADING LIGHTNING CONSTRAINTS 15-0210 _____| (1 ) SAF1-999 | 60 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- S00L00.085 WIND PREDICTION - SRB RETRIEVAL AREA 15-0659 _____| B072-999 | 16-0291 _____| | 16-0819 _____| | 16-0935 _____| | S00U00.010 POST LAUNCH SHUTTLE/PAD AREA INSPECTION 17-0293 _____| (1 ) SAF1-999 | | S00U00.020-A AN ENGINEERING PAD INSPECTION TEAM 16-0430 _____| (1 ) SAF1-999 | | S00U00.020-C INSPECT ORBITER AFT ENGINE 16-0430 _____| (1 ) SAF1-999 | | S00U00.020-D INFRARED SURVEILLANCE 16-0430 _____| (1 ) SAF1-999 | | S00U00.030 PRELAUNCH SHUTTLE/PAD AREA INSPECTION 14-1183 _____| (1 ) SAF1-999 | | S00000.643 SRB RGA POSITIVE/NEGATIVE TORQUE TEST 16-0441 _____| (1R ) SAF1-999;C | 61 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- T09QAL.030 ET TPS INSPECTION ON PAD 14-1358 _____| (1 ) L04 T57-999 | | V05AG0.060-C GN2 PURGE INITIATION TIME 15-0532 _____| L05 V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V05AH0.050-C GN2 PURGE INITIATION TIME 15-0532 _____| L06 V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V05AH0.050-D REDUCED PAYLOAD BAY PURGE RATE 16-1043 _____| L06 V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V05AI0.060-C PURGE PARAMETERS FOR ET LOADING - GN2 15-0532 _____| L04 V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V09AH0.090 RSI - PCR SEAL/INTERFACE 14-1026 _____| (1 ) L03 V02F21-90 | V03F22-90 14-1175 _____| V04F18-90 | V05F12-90 | 62 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V30C00.010 PLBD MOISTURE CONDITIONING 14-1368 _____| V02F25-90;C | V03F25-90;C | V04F21-90;C | V05F13-90;C | | V42BF0.130 VFY CLOSURE OF RCS XFEED VALVES (LCD) 16-0983 _____| V02F20-90 | V03F22-90 | V04F17-90 | V05F12-90 | | V43CF0.110-A LEFT POD TANKS 16-0021 _____| V02F20-90 | V03F22-90 | V04F17-90 | V05F12-90 | | V43CF0.110-B RIGHT POD TANKS 16-0021 _____| V02F20-90 | V03F22-90 | V04F17-90 | V05F12-90 | | V43CF0.120 PERFORM OMS ENGINE ACTIVATION (LCD) 16-0823 _____| V02F20-90 (VWD72/V) | V03F22-90 | V04F17-90 | V05F12-90 | | V43CF0.130 VFY CLOSURE OF OMS XFEED VLVS (LCD) 16-0983 _____| V02F20-90 | V03F22-90 | V04F17-90 | V05F12-90 | 63 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V45CG0.040-A FCP 1 C&W VERIF 16-0399 _____| L02 V02F12-90 | V03F15-90 | V04F11-90 | V05F1-90 | | V45CG0.040-B FCP 2 C&W VERIF 16-0399 _____| L02 V02F12-90 | V03F15-90 | V04F11-90 | V05F1-90 | | V45CG0.040-C FCP 3 C&W VERIF 16-0399 _____| L02 V02F12-90 | V03F15-90 | V04F11-90 | V05F1-90 | | V45CH0.020 PERFORM FUEL CELL CALIBRATION 15-0593 _____| (1R ) L01 V03F23 | PERFORM FUEL CELL CALIBRATION | L02 V02F24-90 | V03F24-90 | V04F20-90 | V05F12-90 | | V45CH0.030 PERFORM PRSD SYSTEM INTEGRITY CHECK 15-0593 _____| (1 ) V02F21-90 | V03F22-90 | V04F18-90 | V05F12-90 | | V45CH0.040 PERFORM PURGE OF FCP 1, 2 AND 3 16-0606 _____| V02F21-90 | V03F22-90 | V04F18-90 | V05F12-90 | 64 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V45CH0.050 PERFORM FCP PRELAUNCH CONDITIONING 16-0996 _____| V02F21-90 | V03F22-90 | V04F18-90 | V05F12-90 | | V51AF0.245 WEIGHT-ON-WHEELS PROXIMITY SWITCHES 14-1014 _____| (1R ) V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V51AF0.250 REDUNDANT WEIGHT ON WHEELS DETECTOR 14-1013 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V51AG0.075-A LH NLG TPDMS LONG TERM DECAY RATE 15-0652 _____| L04 V02F16-20E20;C | V03F18-21E21;C | V04F13-17E17;C | V05F5-11E11;C | LH NLG TPDMS LONG TERM DECAY RATE | L05 V02F21-90R21;C | V03F22-90R22;C | V04F18-90R18;C | V05F12-90R12;C | 65 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V51AG0.075-B RH NLG TPDMS LONG TERM DECAY RATE 15-0652 _____| L04 V02F16-20E20;C | V03F18-21E21;C | V04F13-17E17;C | V05F5-11E11;C | RH NLG TPDMS LONG TERM DECAY RATE | L05 V02F21-90R21;C | V03F22-90R22;C | V04F18-90R18;C | V05F12-90R12;C | | V51AG0.075-C LH INBD TPDMS LONG TERM DECAY RATE 15-0652 _____| L04 V02F16-20E20;C | V03F18-21E21;C | V04F13-17E17;C | V05F5-11E11;C | LH INBD TPDMS LONG TERM DECAY RATE | L05 V02F21-90R21;C | V03F22-90R22;C | V04F18-90R18;C | V05F12-90R12;C | | V51AG0.075-D LH OUTBD TPDMS LONG TERM DECAY RATE 15-0652 _____| L04 V02F16-20E20;C | V03F18-21E21;C | V04F13-17E17;C | V05F5-11E11;C | LH OUTBD TPDMS LONG TERM DECAY RATE | L05 V02F21-90R21;C | V03F22-90R22;C | V04F18-90R18;C | V05F12-90R12;C | 66 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V51AG0.075-E RH INBD TPDMS LONG TERM DECAY RATE 15-0652 _____| L04 V02F16-20E20;C | V03F18-21E21;C | V04F13-17E17;C | V05F5-11E11;C | RH INBD TPDMS LONG TERM DECAY RATE | L05 V02F21-90R21;C | V03F22-90R22;C | V04F18-90R18;C | V05F12-90R12;C | | V51AG0.075-F RH OUTBD TPDMS LONG TERM DECAY RATE 15-0652 _____| L04 V02F16-20E20;C | V03F18-21E21;C | V04F13-17E17;C | V05F5-11E11;C | RH OUTBD TPDMS LONG TERM DECAY RATE | L05 V02F21-90R21;C | V03F22-90R22;C | V04F18-90R18;C | V05F12-90R12;C | | V62AG0.010-D ADJUST TANK QUANTITIES 16-0259 _____| (1R ) L04 V02F21-90 | V03F22-90 | V04F18-90 | V05F12-90 | 67 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V62AG0.050 FUEL CELL WATER LINE VERIFICATION 16-0256 _____| (1R ) L01 V02F20 (VWR05) | V04F17 | V05F11 | FUEL CELL WATER LINE VERIFICATION | L02 V02F21-90 | V03F22-90 | V04F18-90 | V05F12-90 | | V63AR0.025 FES PLUGS FINAL REMOVAL 14-0807 _____| L01 V02F20 | V04F17 | V05F11 | ATCS PLUGS FINAL REMOVAL | L02 V02F21-90 | V03F22-90 | V04F18-90 | V05F12-90 | | V67AA0.030-B SAMPLING AT L-2 TO L-0 DAYS 14-0899 _____| V02F25-90 | V03F25-90 | V04F21-90 | V05F13-90 | 68 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V71AD0.050 IMU GYROCOMPASS ALIGNMENT CHECK 16-0701 _____| (1R ) L02 V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V72CA0.010-A PASS DEU ACTIVATION 14-0078 _____| V02F22-90 | V03F23-90 | V05F12-90 | | V72CA0.010-B BFS DEU ACTIVATION 14-0094 _____| V02F22-90 | V03F23-90 | V05F12-90 | | V72CA0.020 PRELAUNCH BFC/ENGAGE VERIFICATION 14-0064 _____| (1R ) V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V72CA0.030 PRELAUNCH BFC/CRT VERIFICATION 14-0064 _____| (1R ) V02F22-90;C | V03F23-90;C | V04F19-90;C | V05F12-90;C | | V72CA0.050-A REDUNDANT SET ACTIVATION 14-0334 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | 69 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V72CA0.050-B BFS ACTIVATION 14-0092 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V72CA0.050-C BFS DUMP & COMPARE 14-0092 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V72CA0.060-A BFS ONE SHOT TRANSFER PREPS 16-0816 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V72CA0.060-B BFS ONE SHOT DATA TRANSFER 16-0851 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V72CA0.070 POWER DOWN CMD DECODERS 16-0876 _____| V02F22-90 (SLP26) | V03F23-90 | V04F19-90 | V05F12-90 | | V74AB0.020 TACAN SELF TEST 14-0301 _____| (1R_ ) VAF1-90;C (SELF) | | V74AB0.102 BLANKING AT PAD 14-0301 _____| (1R ) V02F20-90;C (BLANKIN) | V03F22-90;C | V04F17-90;C | V05F11-90;C | 70 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V74AB0.190 TACAN GROUND STATION INTERFACE 14-0301 _____| (1R_ ) VAF1-90;C (GROUND) | | V74AC0.011 RADAR ALT. POWER ON VERIFICATION 14-0301 _____| (1R_ ) VAF1-90;C (PWR) | | V74AC0.020 RADAR ALTIMETER SELF TEST 14-0301 _____| (1R_ ) VAF1-90;C (SELF) | | V74AD0.020 MSBLS SELF TEST 14-0301 _____| (1R_ ) VAF1-90;C (SELF) | | V75AP0.010 CONFIGURE OI PCMMU FOR LCD (GND CNTR) 14-0282 _____| (1R ) V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V75AP0.020 VERIFY OPS & P/L RCDRS CONFIG FOR LCD 14-0843 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V75AP0.030 MTU OSC FREQ VERIFY 14-0176 _____| (1R ) V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V75AP0.040 OI PCMMU CONFIG FOR PNL CONTROL 16-0306 _____| (1R ) V02F22-90 | V03F23-90 18-0095 _____| V04F19-90 | V05F12-90 | 71 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP --------------------------------------- VEHICLE/ELEMENT NO. ORB_____/FLT_____ ET_____ SRB_____ LH___ RH___ GROUND HARDWARE PMN/SN _________ COMPONENT/SEGMENT ___________/FLT_____ SITE ______ TCN _______________ DATE ___________ TOP WAS RUN AS A STANDALONE YES _____ NO _____ TOP WAS RUN AS A SUBTASK TO TOP _________________. NOMENCLATURE/ SEQ-STEP QC/ENG OMRS NO./CIL NO EFFECTIVITY (CAP) VERIF --------------- ------------- -------- ----- V78GA0.010 VFY MTU OEX/MADS TIMING SIGNALS 14-0184 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V78GA0.020 CONFIGURE MADS/OEX FOR TERMINAL COUNT 14-0843 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V78GA0.030 MADS PCM AND WB DATA STAT CK 14-0184 _____| V02F22-90 | V03F23-90 | V04F19-90 | V05F12-90 | | V79AS0.012 FWD RCS SINGLE CMD TEST 15-0317 _____| (1 ) VAF1-90;C (VSB53) | | V79AS0.013 FWD RCS SINGLE CMD TEST 15-0317 _____| (1 ) VAF1-90;C (VSB53) | | V79AS0.062 AFT LEFT RCS SINGLE CMD TEST 15-0317 _____| (1 ) VAF1-90;C (VSB53) | | V79AS0.063 AFT LEFT RCS SINGLE CMD TEST 15-0317 _____| (1 ) VAF1-90;C (VSB53) | | V79AS0.110 AFT RIGHT RCS SINGLE CMD TEST 15-0317 _____| (1 ) VAF1-90;C (VSB53) | | V79AZ0.090 OMS ACTUATOR STOW POSITION FOR LAUNCH 15-0342 _____| (1 ) V02F22-90 (SWB02) | V03F22-90 | V04F18-90 | V05F12-90 | 72 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR SECTION IV OPERATION INSTRUCTIONS ---------------------- SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 13-0000 CALL TO STATION --------------- 13-0001 -1D19H00M NTD PERFORM SHUTTLE COUNTDOWN CALL SU72007 T-43H00M TO STATIONS. (HOLDING) 13-0002 NTD ALL PERSONNEL SUPPORTING PA S0007, SHUTTLE COUNTDOWN, REPORT ON STATION FOR TEST STATUS CHECK 13-0003 NTD CMQC REPORT S0007 CONSTRAINT STATUS. 232 13-0004 NTD CMQC VERIFY INTEGRATED PRE-OPERATION 232 SETUPS 1 AND 2 ARE COMPLETE. 13-0005 -1D19H00M NTD STM VERIFY VOICE RECORDINGS AS T-43H00M 232 SCHEDULED FOR S0007. (HOLDING) 13-0006 NTD ANNOTATE VOICE TAPE: 232 DATE __________ TIME __________ GMT VEHICLE __________ LOCATION __________ STS - __________ 73 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 13-0007 NTD OTC PERFORM S0007 CALL TO STATION AND 232 TBC REPORT TEST READINESS STATUS. STM FOLLOWING IS CURRENT REVISION LEVEL *SCC AND DATE FOR EFFECTIVE S0007 VOLUMES PTC FOR THIS LAUNCH. VERIFY ALL YOUR LPS ACTIVE SYSTEMS HAVE CORRECT REVISION AVAILABLE. VOL 1 (PREPS) REV ___ DATE __________ VOL 2 (OPR SEQ) REV ___ DATE __________ VOL 3 (RECYCLE) REV ___ DATE __________ VOL 4 (SYST SEQ) REV ___ DATE __________ VOL 5 (CONTINGENCY/EMERGENCY) REV ___ DATE __________ 13-0008 NTD *SCC VERIFY ALL SF PREPS COMPLETE 232 AND READY TO SUPPORT S0007. 13-0009 LPS JSDC VERIFY FOLLOWING: | 127 1. SDC PERSONNEL AND | EQUIPMENT READY TO SUPPORT S0007. 2. PCGOAL TO LAUNCH CONTROL ROOM RESTRICTED TO S0007 DATA ONLY. 13-0010 LPS JRPS VERIFY RPS READY TO SUPPORT LAUNCH 127 COUNTDOWN. 13-0011 NTD LPS VERIFY LPS READY TO SUPPORT 232 LAUNCH COUNTDOWN. TCID __________ REV _____ MOD _____ OPERATING SYSTEM _________ 74 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 13-0012 NTD STM REQUEST JBFX REPORT TO NTD ON WSSA 232 CHANNEL 232 FOR COMM CHECK AND SU72066 STM JBFX BRIEFING, MONITOR CHANNEL 232 111 AND STANDBY TO FLOW FIREX WATER DIRECTED BY NTD PER EMERGENCY INSTRUCTIONS, VOL 5 APPENDIX Z. 13-0013 NTD OTC VERIFY ORBITER IN STANDARD POWER 232 CONFIGURATION. SET COUNTDOWN CLOCK ------------------- 13-0014 -1D19H00M NTD CGLS SET COUNTDOWN CLOCK TO T-43H00M 232 __ DAY, __ HOURS, __ MINUTES, (HOLDING) __ SECONDS, AND COMMENCE COUNTING AT __________ GMT 13-0015 CGLS HOME CMD KEY - PRESS CDTS - __:____/__ DD HHMM SS XMIT CMD KEY - PRESS 13-0016 CGLS HOME CMD KEY - PRESS CDTC __ __ / __ . 000 HH MM SS XMIT CMD KEY - PRESS 13-0017 CGLS NTD THE COUNTDOWN CLOCK IS AT 232 __ DAYS, __ HOURS, __ MINS, __ SEC AND HOLDING 75 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORBITER ------- 13-0018 OTC CMQC VERIFY ORBITER PRE-OPERATION SU72031 132 SETUP 1 - PRE-OPERATION SETUP SUMMARY SHEET COMPLETE. 13-0019 -1D19H00M OTC ALL ORBITER PERSONNEL SUPPORTING T-43H00M 132 S0007, SHUTTLE COUNTDOWN, (HOLDING) REPORT TEST READINESS STATUS CGLS LCC FR GROUND LAUNCH SEQUENCER ENGR CEPD LCC FR ELECTRICAL POWER SYSTEM LEAD REPORTS FOR QPDS, PPDS CISL LCC FR ORBITER INSTRUMENTATION SYSTEM LEAD REPORTS FOR (JISE) CECL LCC FR ENVIRONMENTAL CONTROL LEAD REPORTS FOR: PGCU PAD GROUND COOLANT UNIT TECH CDPS LCC FR ORBITER DATA PROCESSING SYSTEM ENGINEER *PAD PAD LEADER CMQC LCC FR QUALITY CONTROL (SYSTEM ENGINEER COVERAGE) REPORTS FOR PQCG - PAD QUALITY CONTROL GENERAL CDR COMMANDER (ORBITER LEFT SEAT) PLT PILOT (ORBITER RIGHT SEAT) CTPE LCC FR TEST PROJECT ENGINEER 76 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 13-0020 OTC CEPD VERIFY FOLLOWING PROGRAMS INACTIVE, 132 THEY SHALL REMAIN INACTIVE FOR DURATION. OF THIS OMI. VWC12 - MEC CRITICAL CMD VWC13 - GROUND PICS 13-0021 OTC NTD ORBITER READY FOR S0007 232 PAYLOAD ------- 13-0022 NTD PTC VERIFY PAYLOAD SYSTEMS AND PERSONNEL 232 ARE READY TO SUPPORT LAUNCH COUNTDOWN OPERATIONS. 13-0023 PTC NTD PAYLOAD ELEMENTS READY FOR S0007. 232 | NOTE | | PERFORM THE FOLLOWING STEP | FOR STS-93. | | 13-0024 PTC OTC PERFORM ORBITER OPERATION SUPPORT | 132 SETUP 15 - PAYLOAD BAY PURGE | OTC CMQC VERIFICATION. | CPVD | PPVM | | NOTIFY PTC IMMEDIATELY IF PURGE | GOES OUT OF SPEC. (STS-93) | NOT PERFORMED ______| EXTERNAL TANK/SRB ----------------- 13-0025 -1D19H00M TBC CMQC VERIFY EXTERNAL TANK AND SRB SU72047 T-43H00M 136 PRE-OPERATION SETUP 1 - PRE-OPERATION (HOLDING) SETUP SUMMARY SHEETS COMPLETE. 13-0026 TBC NTD ET/SRB READY FOR S0007. 232 77 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SUPPORT ------- 13-0027 -1D19H00M STM ALL SUPPORT PERSONNEL SU72064 T-43H00M NET SUPPORTING S0007 SHUTTLE (HOLDING) 104 LAUNCH COUNTDOWN REPORT TEST READINESS STATUS. 104 QBSE MOBILE STRUCTURES ENG STA | VEEE ELEVATOR CONTROL CDPD 111 GYCC COMMUNICATIONS CONTROLLER COMM JTCR TIMING COUNTDOWN AND PHOTO CNTRL JCFM ESMS MEASUREMENT CONTROLLER JCTL INTEGR CONSOLE REPORTS FOR: PCMP PAD CRANE CONT CDPA JBEP POWER CONSOLE LEAD PWR JBPN PNEUMATICS CONSOLE PNSA JBAC HVAC CONSOLE HVAA JBFX FIREX/POT. WATER CONSOLE WSSA JBWC SOUND SUPPRESSION CONSOLE WSSA JBDY SUPPORT SERV CONT REPORTS FOR: GHBE HEAVY EQUIP HESA JSTC J-BOSC TEST CONDUCTOR, JSTC REPORTS FOR: JSEP POWER CONSOLE LEAD ELEC GSPN PNEUMATICS CONSOLE PNU JSAC HVAC CONSOLE AC JFIR FIRE CONSOLE FIRE PMEH ENV HEALTH TECH EH *SCB SCAPE SUITING TRAILER LS JSDY SUPPORT SERV CONT JSTC JSQC R&QA CONT QA WCRG ROADS AND GROUNDS RGR *SEC SECURITY CONSOLE SEC GSFA FIRE ALARMS FA 13-0028 NTD STM VERIFY SUPPORT PRE-OPERATION 232 SUMMARY SHEET COMPLETE. 13-0029 STM NTD SUPPORT READY FOR S0007. 232 SAFETY ------ 13-0030 *SCC *PSE REPORT TEST READINESS STATUS ON SEC NET *SEC RADIO NET - 105 FIRE 105 JFIR 78 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 13-0031 NTD OTC VERIFY READY TO PROCEED WITH SU72007 232 TBC OPERATIONAL SEQUENCES *SCC STM LPS PTC NOTE HOLDS - (STOPPING THE COUNTDOWN CLOCK) PRIOR TO T-20 MINUTES. A HOLD MAY BE REQUESTED BY: LD - LAUNCH DIRECTOR OTC - ORBITER TEST CONDUCTOR TBC - TANK/BOOSTER TEST CONDUCTOR PTC - PAYLOAD TEST CONDUCTOR PTD - NASA PAYLOAD TEST DIRECTOR CSPE - SHUTTLE PROJECT ENGR STM - SUPPORT TEST MANAGER *SCC - SAFETY MANAGER LCC SRO - SUPERINTENDANT OF RANGE OPERATIONS *FLT - FLIGHT DIRECTOR *MIL - MILA LPS - LPS TEST CONDUCTOR REQUEST FOR A HOLD WILL BE MADE TO THE NASA TEST DIRECTOR (NTD) ON OIS CH 232. THE NTD WILL EVALUATE THE REQUEST AND WILL HOLD THE CLOCK AT THE MOST ADVANTAGEOUS TIME. SRB OI POWER UP FOR INSTRUMENTATION SCANS WILL BE PER S9001VL1 OPTION B ONLY. SRSS VEHICLE POWER SHALL NOT BE ACTIVATED BEFORE T-50 MINUTES. 79 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 80 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0000 SHUTTLE COUNTDOWN CONTROL ------------------------- SEQUENCE (-43H THRU -11H) ------------------------- NOTE OPERATIONS INVOLVING CRIT 1, 1R AND/OR 1S ITEMS ARE CONTAINED IN THE FOLLOWING SEQUENCE/STEPS. 14-0001 CGLS NTD THE CDC STARTED AT ________ GMT. 14-0002 NTD LAUNCH COUNTDOWN IS NOW IN PA PROGRESS. 232 FACILITY GO2/GH2 SUPPORT ------------------------ 14-0003 -1D19H00M STM JBPN PERFORM FOLLOWING: PNSA T-43H00M 111 1. VERIFY GH2 FIRE AND LEAK DETECTORS ARE NOT IN ALARM AND WITHIN ACCEPTABLE LIMITS C1 CONSOLE. 2. VERIFY PAD ___ GH2 AUTO FIRE MONITOR PROGRAM OFF AT THIS TIME. (NGHXOW43E/PAD A) (NGHX0Y39E/PAD B) 14-0004 JSTC JFIR (1P10) PLACE LCC ALARM BELLS IN 114 BYPASS. SRB ESP'S ON TRANSPORTER ------------------------ 14-0005 TBC CMQC VERIFY SRB PRE-OPERATION SETUP SU72050 136 4 - SRB ESP OPERATIONS COMPLETE. 14-0006 TBC CMQC VERIFY SRB PRE-OPERATION SETUP SU72051 136 6 - SRB AFT SKIRT GN2 PURGE SKID SU72124 ACTIVATION COMPLETE. 81 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING SRB AFT SKIRTS WILL BE PURGED WITH GN2 FLOW TO MAINTAIN REQUIRED SRB TEMPERATURES. NOTE PERFORM NEXT STEP IF BEARING PURGE REQUIRED. 14-0007 TBC CBHY PERFORM SRB OPERATION SUPPORT SU72049 136 SETUP 5 - SRB AFT SKIRT GN2 SU72074 PURGE ACTIVATION AS TEMPERATURES REQUIRE. NOT PERFORMED ______ PRESSURIZE ELEVATOR/MACHINE ROOMS --------------------------------- 14-0008 STM VEEE UNLOCK RSS ELEVATOR MACHINE ROOM CDPD NET TO SUPPORT PRESSURIZATION. VERIFY 104 WHEN COMPLETE. 14-0009 -1D19H00M NTD STM PRESSURIZE FSS ELEVATOR, HVAA T-43H00M 232 RSS ELEVATOR AND HOIST MACHINE SU72069 STM JBAC ROOMS PER OMI M3034 PAD A AND B. 111 VERIFY WHEN COMPLETE. 14-0010 -1D19H00M OTC *PAD START VERIFICATION OF ORBITER SU72023 T-43H00M 132 DOOR PANEL CONFIGURATION FOR TANKING AND LAUNCH PER ORBITER OPERATION SUPPORT SETUP 2, PART A. PAD AND MLP CAMERA SETUP ------------------------ 14-0011 STM JPHO PERFORM FILM CAMERA SETUP ON SU72063 111 MLP/FSS AND PAD PERIMETER SU72416 (TO BE COMPLETED PRIOR TO T-09H15M). 82 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE PAD WARNING LIGHTS --------------------------- 14-0012 -1D19H00M NTD *SCC SET PAD WARNING LIGHTS AT B, E SU72075 T-43H00M 232 AND F ROADS, HIGH PRESS BATTERY *SCC *PSE AND PTCR N&S STAIRWELL TO FLASHING NET AMBER. 105 14-0013 *PSE *SCC WARNING LIGHTS AT B,E AND F ROADS, NET HIGH PRESSURE BATTERY AND PTCR N&S 105 STAIRWELL ARE FLASHING AMBER. *SCC NTD 232 INHIBIT ADMIN PAGING -------------------- 14-0014 -1D19H00M STM GYCC INHIBIT ADMIN PAGING TO COMM T-43H00M 111 JBDY PAD _____. SU72067 GYCC JYCD 117 TERMINATE WIRE FRAME WORK ------------------------- 14-0015 STM GYCC VERIFY ALL ROUTINE WORK ON WIRE COMM 111 FRAMES TERMINATED, WARNING LIGHTS ACTIVATED AND EXCEPTION ACCESS PROCEDURE IN EFFECT FOR SHUTTLE LAUNCH COUNTDOWN. (FRAMES TO BE IN CONTROLLED MODE) CONFIGURE NMAJORTEST PSEUDO --------------------------- 14-0016 LPS ISSUE NMAJORTEST PSEUDO TO VALUE OF 0007 HEXADECIMAL (7 DECIMAL). 83 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MMU COMPARE TAPE/FILE CHECK IN ------------------------------ 14-0017 -1D19H00M OTC CVFS PERFORM ORBITER OPERATION SUPPORT SU72033 T-43H00M 132 LPS SETUP 7 - MEMORY COMPARE TAPE/FILE CHECK-IN. (15 MIN) OTV CAMERA USAGE ---------------- 14-0018 NTD OTC OTV CAMERA USAGE ASSIGNMENTS COMM 232 TBC FOR COUNTDOWN ARE PER OTV STM CAMERA USAGE MATRIX, FIG 4 *SCC (IN FRONT SECTION OF THIS STM JYVO VOLUME). 138 TRANSFER ORBITER MAIN BUS POWER ------------------------------- SUPPLIES TO LOCAL SENSE ----------------------- NOTE A QUIET BUS IS REQUIRED FOR THE FOLLOWING OPERATION. EQUIPMENT POWER UP OR DOWN IS NOT PERMITTED UNTIL COMPLETION REPORTED. 14-0019 -1D19H00M OTC CEPD TRANSFER ORBITER MAIN BUS POWER SU72035 T-43H00M 132 SUPPLIES TO LOCAL SENSE AND ACTIVATE LOCAL SENSE VOLTAGE CONTROL PROGRAM PER OMI S9001VL2 (15 MIN). RT OMI LOG NO.__________ ORBITER TIRR LOG ---------------- 14-0020 OTC *PAD BEGIN ORBITER TIRR LOG CLOSURE. SU72025 132 84 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TFL/DFL ------- 14-0021 -1D19H00M OTC CDPS PERFORM ORBITER OPERATION SU72010 T-43H00M 132 SUPPORT SETUP 24 - TFL/DFL (15 MIN). OMRS S00FA0.301 MEC CRITICAL CMD STATUS ----------------------- 14-0022 OTC CEPD VERIFY MEC CRITICAL CMDS SU72013 132 DISABLED. 14-0023 CEPD CRT (SWC02) MEC CRIT CMD DSBL 14-0024 CEPD OTC MEC CRITICAL CMDS DISABLED. 132 14-0025 OTC CEPD MEC CRITICAL CMDS DISABLED AND 132 SHALL REMAIN DISABLED FOR REMAINDER 232 NTD OF TEST. NTD *SCC TBC 85 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0026 CDPS OTC ORBITER OPERATION SUPPORT SU72010 132 SETUP 24 - TFL/DFL COMPLETE. 14-0027 CVFS OTC MEMORY COMPARE TAPE/FILE SU72033 132 CHECK IN COMPLETE. MAIN BUS PWR SUPPLY TRANSFER COMPLETE ------------------------------------- 14-0028 CEPD OTC ORBITER MAIN BUS POWER SUPPLY SU72035 132 TRANSFER TO LOCAL SENSE COMPLETED. NOTE DO NOT PERFORM BFC TEST UNTIL MAIN BUS POWER SUPPLY TRANSFER IS COMPLETE. BFC TEST -------- 14-0029 -1D18H45M OTC NTD DPS WILL BE CONFIGURED TO OPS 0 DL T-42H45M 232 FMT 20 WITH MDM'S FF1, FF2 AND FF3 NTD TBC POWERED OFF. LDB SILENCE IS REQUIRED PTC DURING TEST.(APPROXIMATELY 1 HOUR). LPS GMT AND MET UPDATE WILL BE PERFORMED OTC ALL UPON TEST COMPLETION. 132 14-0030 -1D18H45M OTC CDPS PERFORM ORBITER BACKUP FLT SU72016 T-42H45M 132 CONTROLLER TEST PER S0007VL4 (SEQ 49 ITEM 1). (55 MIN) OMRS V72CA0.020-1R OMRS V72CA0.030-1R 14-0031 -1D18H30M TBC *PAD LOX DUMP BASIN SU72052 T-42H30M 136 A253 (VENT LINE S/O) VLV - OPEN (CCW) *PAD PL04 INSTALL CHAIN AND LOCK 86 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PREFLT VOLTS ADJUST ------------------- 14-0032 -1D18H30M OTC CEPD ADJUST PREFLT VOLTAGE TO REDUCE SU72037 T-42H30M 132 PREFLT TO ESS BUS LOAD 14-0033 CEPD CRT (VWC17) PF1 (1D500) ITCU VOLTAGE _____ DD PF1 (1D500) ITCU CURRENT _____ DD PF2 (1D600) ITCU VOLTAGE _____ DD PF2 (1D600) ITCU CURRENT _____ DD NOTE DO NOT PERFORM NEXT TWO STEPS IF PRE-FLIGHT VOLTAGES ARE BETWEEN 29.0 AND 29.5 VDC. 14-0034 CEPD CURSOR CNTL (VWC17) USING UP/DOWN ADJUST CURSORS, REDUCE PF1 AND PF2 ITCU VOLTS TO BETWEEN 29.0 AND 29.5 VDC NOT PERFORMED ______ 14-0035 CEPD CRT (VWC17) ADJUSTED VOLTS AND AMPS PF1 (1D500) ITCU VOLTAGE _____ DD PF1 (1D500) ITCU CURRENT _____ DD PF2 (1D600) ITCU VOLTAGE _____ DD PF2 (1D600) ITCU CURRENT _____ DD NOT PERFORMED ______ 87 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 1D500 BATTERY BACKUP ENABLE --------------------------- NOTE DO NOT PERFORM NEXT STEP IF LISTED CB'S ARE FOUND IN INDICATED POSITION. 14-0036 CEPD QPDS PANEL L24 (COMPT 9A) CKT 17 CB 17 - ON CKT 25 CB 25 - ON T:______ NOT PERFORMED ______ 14-0037 CEPD QPDS RACK 6840 BATTERY CHARGER (PANEL A3) MAIN CB - ON CONTROL AND MONITOR PANEL (A4) INTERRUPT/NORMAL SW - NORMAL T:______ 14-0038 CEPD CRT (VWC16) PREFLT ITCU 1 VOLTAGE __________ VDC BD CRT (VWC01) BATTERY BACKUP 1D500 HI-TP V __________ VDC BD 88 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 1D600 BATTERY BACKUP ENABLE --------------------------- NOTE DO NOT PERFORM NEXT STEP IF LISTED CB'S ARE FOUND IN INDICATED POSITION. 14-0039 CEPD QPDS PANEL L24 (COMPT 9A) CKT 19 CB 19 - ON CKT 26 CB 26 - ON T:______ NOT PERFORMED ______ 14-0040 CEPD QPDS RACK 6841 BATTERY CHARGER (PANEL A3) MAIN CB - ON CONTROL AND MONITOR PANEL (A4) INTERRUPT/NORMAL SW - NORMAL T:______ 14-0041 CEPD CRT (VWC16) PREFLT ITCU 2 VOLTAGE __________ VDC BD CRT (VWC01) BATTERY BACKUP 1D600 HI-TP V __________ VDC BD 14-0042 CEPD OTC PREFLIGHT BATTERY BACKUP ENABLE 132 COMPLETE. 89 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OMS/RCS C&W RECONFIGURATION --------------------------- NOTE LIMIT CHANGE REQUIRED TO PREVENT MASTER ALARMS PRIOR TO ASCENT SWITCHLIST. (OMS ULLAGE PRESSURE NEAR C&W TRIP POINT). 14-0043 -1D18H30M OTC COOS PERFORM OMS/RCS C&W SU72038 T-42H30M 132 RECONFIGURATION. 14-0044 COOS PLT PANEL R13U CAUTION AND WARNING 1. PARAMETER SELECT TW'S - 007 LIMIT SET VALUE TW - 3.60 LIMIT SW - UPPER FUNC SW - SET/THEN READ VERIFY 007 IS 3.60 2. PARAM SEL TW'S - 017 FUNC SW - SET/THEN READ VERIFY 017 IS 3.60 3. PARAM SEL TW'S -037 FUNC SW - SET/THEN READ VERIFY 037 IS 3.60 4. PARAM SEL TW'S -047 FUNC SW - SET/THEN READ VERIFY 047 IS 3.60 5. (OMS KIT OX TK ULLAGE) PARAM SELECT TW'S - 077 PARAM SW - INHIBIT, REL PARAM STATUS SW - INHIBITED, HOLD VERIFY STATUS LT 077 - ON PARAM STATUS SW - CENTER 6. (OMS KIT FU TK ULLAGE) PARAM SELECT TW'S - 087 PARAM SW - INHIBIT, REL PARAM STATUS SW - INHIBITED, HOLD VERIFY STATUS LT 087 - ON PARAM STATUS SW - CENTER 7. PARAM SEL TW'S -120 90 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0045 COOS OTC OMS/RCS C&W RECONFIG COMPLETE. 132 14-0046 OTC CISL PERFORM C&W GOAL SOFTWARE UPDATE | 132 FOR OMS/RCS PARAMETERS PER | OMI S9001VL2. | L-3 DAY POTABLE H2O SAMPLE -------------------------- AND TANK A QTY ADJUST --------------------- 14-0047 -1D18H00M OTC CFCP PERFORM ORBITER POTABLE (L-3 SU72040 T-42H00M 132 DAY) WATER SAMPLES AND TANK A SU72072 232 NTD QUANTITY ADJUST PER S0007VL4 NTD STM (SEQ 54 OPTION B) ON OIS CH 153. 232 (1 HR) (BI01-853-3281/BEEPER STM WBIO 454-0488) WMC FINAL STOWAGE COMPLETE -------------------------- NOTE DO NOT PERFORM NEXT STEP IF ALREADY COMPLETED FOR MVAK MISSIONS. 14-0048 *PAD OTC ORBITER PRE-OPERATION SETUP 20 - SU72043 132 WMC FINAL STOWAGE COMPLETE. NOT PERFORMED ______ VERIFY AIR PURGES ----------------- 14-0049 -1D18H00M OTC *PAD VERIFY ORBITER FORWARD, PAYLOAD T-42H00M 132 PPVM BAY, AND AFT COMPARTMENTS AIR PURGE ACTIVATED PER V1122. 91 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT STEP IF MASS SPEC HAS ALREADY BEEN REMOVED FROM MLP. 14-0050 *PAD OTC PROVIDE GSS STRUCTURES AND STSA | 132 SFOC HEAVY EQUIPMENT SUPPORT AND HESA OTC NTD REMOVE MASS SPEC MACHINE FROM MLP SU72061 232 COMPARTMENT 43A. NTD STM STM QBSE 111 GBHE JBDY NOT PERFORMED ______ REMOVE PPU FROM MLP ------------------- NOTE PERFORM NEXT STEP IF PPU WAS NOT REMOVED UPON ARRIVAL AT PAD. 14-0051 OTC NTD REMOVE PPU (S70-0534) FROM ZERO HESA 232 LEVEL MLP. (4 HRS) NTD STM STM JBDY 111 JBDY GBHE NET 104 NOT PERFORMED ______ ESSENTIAL PERSONNEL ------------------- GSS --- SUPVR/ENG 1 TECH 6 92 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LPS CONSOLE SETUPS ------------------ 14-0052 -1D18H00M NTD LPS PERFORM MASTER CONSOLE SETUPS. SU72071 T-42H00M 232 NOTE NEXT STEP TAKES APPROX. 10 MINUTES TO COMPLETE. 14-0053 LPS C1MC PERFORM $FEPCPR, REINIT AND DEMAND UPDATE ALL FEPS PER OMI C2000. TERM $FEPCPR AT COMPLETION OF DEMAND UPDATE. 14-0054 LPS C1MC VERIFY ACTIVE PROGRAMS AT MASTER CONSOLE: $HWMON (TCB1) AA008/AWP02 (TCB2) AA009/AWP01 (TCB4) 14-0055 LPS C1MC VERIFY VIA AWP02 (PGB) FOTE DUAL POWER MONITORS INDICATE ON. 14-0056 LPS C1MC VERIFY (AWP05 PGB PAD A OR AWP06 PGB PAD B) HIMS 5982, 5987, 6377 AND 6378 DISPLAYED IN MIXED MODE. 14-0057 LPS C1MC ON VSB TELEMETRY SCREEN VERIFY FRAME COUNT INCREMENTING AND NO PACKET ERRORS. 14-0058 LPS C1MC RECORD ANY REDUNDANT CPU'S NOT IN STANDARD H/W OR S/W CONFIGURATION. (TCG,GSE,PDR/SPA,LDB,OI,GPC,PLD) __________________________________ __________________________________ ___________________________________ 14-0059 -1D18H00M LPS VERIFY ALL REDUNDANT SWITCHES T-42H00M ACTIVE. 93 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0060 LPS C1SE DUMP GS2A FEP AND VERIFY AT LEAST 127 CTPE 14 AVAILABLE 100 SAMPLE PER SECOND SLOTS. RETAIN OUTPUT ON STATION. RECORD ACTUAL NUMBER AVAILABLE_____ 14-0061 LPS NTD VEHICLE SAFING PROCESSOR WILL 232 BE RESET. SAFING INDICATORS NTD OTC AND METERS WILL CYCLE ON AND OFF. TBC PLEASE DISREGARD UNTIL THIS SAFING STEP COMPLETED. THIS STEP TAKES 1 MINUTE TO COMPLETE CYCLE. 14-0062 LPS C1SE VSB FEP, PRESS RESET SWITCH ON MVME 167 PANEL. VERIFY FIRING ROOM CONSUMABLES | ------------------------------ | 14-0063 -1D18H00M LPS VERIFY FIRING ROOM CONSUMABLES. SU72071 | T-42H00M | BACKUP FLT CONTROLLER TEST COMPLETE ----------------------------------- 14-0064 -1D17H50M CDPS OTC BACKUP FLT CONTROLLER TEST SU72016 T-41H50M 132 COMPLETE (SEQ 49 S0007VL4). OTC NTD LDB SILENCE NO LONGER REQUIRED. 232 NTD TBC PTC LPS OMRSD V72CA0.020-1R OMRSD V72CA0.030-1R 14-0065 OTC CDPS PERFORM DEU 1/2/4 LOAD PER SU72019 132 S0007VL4 (SEQ 49 ITEM 2). OMRS V72CA0.010-A 94 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM ET OI POWERUP IF ALREADY UP. ET OI POWER UP -------------- NOT PERFORMED ______ 14-0066 -1D17H45M NTD TBC PROCEED WITH ET OI POWER UP. SU72053 T-41H45M 232 14-0067 TBC CMPS PERFORM ET OI POWER UP. 136 14-0068 CMPS IF SAE12 NOT ACTIVE: CONSOLE KYBD SAE12 PERF PGM KEY - PRESS NOT PERFORMED ______ 14-0069 CMPL IF SAE02 NOT ACTIVE: CONSOLE KYBD SAE02 PERF PGM KEY - PRESS NOT PERFORMED ______ 14-0070 CMPS PFP (SAE12) PFPK4 TURN ON ET PWR - PRESS CRT VERIFY ET OI PWR ON 14-0071 CMPL IF NO LONGER REQUIRED SAE02 TERMINATE PFK15 PRESS TWICE NOT PERFORMED ______ 95 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0072 CMPS IF NO LONGER REQUIRED SAE12 TERMINATE PFK15 PRESS TWICE NOT PERFORMED ______ 14-0073 -1D17H45M CMPS TBC ET OI POWER UP COMPLETE. SU72053 T-41H45M 136 TBC NTD 232 ET OI POWER UP COMPLETE ----------------------- NOTE FOLLOWING STEP SUPPORTS ET HEATER VERIFICATION. 14-0074 TBC *PAD VERIFY KEY FOR ACCESS TO FOLLOWING 136 PTCR ROOMS AVAILABLE. *PAD PPWR PAD A ROOMS 204 AND 210 PAD B ROOMS 203 AND 210 DPS TO G9 SIMPLEX ----------------- NOTE IN NEXT TWO STEPS, DL FMT WILL BE 60 IF REQUIRED FOR PAYLOAD SUPPORT, 44 FOR ALL OTHERS. 14-0075 -1D17H40M OTC CDPS TRANSITION GPC 1 TO G9 SIMPLEX, SU72020 T-41H40M 132 DL FMT _____ (44 OR 60) PER S0007VL4 (SEQ 49 ITEM 3) (5 MIN). 14-0076 CDPS OTC TRANSITION TO G9 SIMPLEX, 132 FMT _____ (44 OR 60) COMPLETE. OTC NTD FLIGHT CRITICAL MDM DATA NOW 232 VALID. NTD PTC TBC 96 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DEU 1/2/4 DUMP AND COMPARE -------------------------- 14-0077 -1D17H40M OTC CODS PERFORM DEU 1/2/4 MEMORY DUMP SU72022 T-41H40M 132 LPS AND COMPARE PER S0007VL4 (SEQ 49 ITEM 4) (15 MIN). OMRS V72CA0.010-A DEU 1/2/4 DUMP AND COMPARE - COMPLETE ------------------------------------- 14-0078 -1D17H25M CODS OTC DEU 1/2/4 DUMP AND COMPARE SU72022 T-41H25M 132 COMPLETE (SEQ 49, S0007VL4). OMRSD V72CA0.010-A BFS LOAD DUMP/COMPARE --------------------- 14-0079 OTC CDPS LOAD, DUMP AND COMPARE BFS SU72006 132 CVFS PROGRAM IN GPC 5 PER "DPS SYSTEMS" LPS (SEQ 49, ITEM 5 AND 6) ON CH 152 (45 MIN). OMRS V72CA0.050-B OMRS V72CA0.050-C OMRS V72CA0.010-B NOTE PERFORM NEXT STEP IF BFS DUMP AND COMPARE (ALTERNATE METHOD) USING LPS RETRIEVAL METHOD DESIRED. 14-0080 OTC CVFS PERFORM BFS RETRIEVAL AND 132 LPS COMPARE USING LPS PER "DPS SYSTEMS" (SEQ 49 ITEM 8) ON CH 152 (30 MIN). NOT PERFORMED ______ 97 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM FOLLOWING THREE STEPS IF WASTE TANK VALVE INDICATES CLOSE. 14-0081 CECL CDR PANEL ML86B ROW B MN A WASTE H2O TK 1 VLV CB - CLOSE NOT PERFORMED ______ 14-0082 CECL CDR PANEL ML31C WASTE H2O TK 1 VLV SW - OPEN (15 SEC MAX) UNTIL TB OP, REL NOT PERFORMED ______ 14-0083 CECL CRT (VAG31, PG-B) TK 1 VLV POP ON NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF VAG60 IS ACTIVE AND IN AUTO MODE. 14-0084 CECL VAG60 AUTO XMIT CURSOR KEY - PRESS VERIFY VAG60 IN MANUAL MODE NOT PERFORMED ______ CONFIG COOLING -------------- 14-0085 -1D17H15M OTC CECL PERFORM GSE/ORBITER COOLING SU72044 T-41H15M 132 ACTIVATION OR RECONFIGURATION PER FOLLOWING TABLE PER OMI S9001VL1 ON CH 143. (30 MIN) 98 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONFIGURATION TABLE ------------------- GCU'S AS REQUIRED FCL 1 PUMP A (CABIN SW) FCL 2 PUMP A (CABIN SW) WCL 1 PUMP A (CABIN SW) AV BAY 1 FAN A (CABIN SW) AV BAY 2 FAN B (CABIN SW) AV BAY 3 FAN A (CABIN SW) HUMIDITY SEP A CABIN FAN B (CABIN SW) NOTE ALLOW FAN A TO RUN INDEPENDENTLY FOR 2 MINUTES MINIMUM PRIOR TO PERFORMING FAN C - ON, TO VERIFY ABILITY TO SUPPORT COUNTDOWN OPERATIONS. IMU FAN A AND C (CABIN SW) 14-0086 CECL CURSOR CNTL (VAG60) AUTO XMIT CURSOR KEY - PRESS CRT VERIFY VAG60 IN AUTO MODE 14-0087 -1D17H00M CFCP OTC ORBITER POTABLE (L-3 DAY) WATER SU72040 T-41H00M 132 SAMPLES AND TANK A QUANTITY ADJUST COMPLETE. 99 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WASTE TANK QUANTITY ADJ (CONTINGENCY) ------------------------------------- NOTE PERFORM NEXT STEP IF WASTE TANK QUANTITY ADJUST REQUIRED AS PART OF COUNTDOWN. ACCESS TO WCS IS REQUIRED TO SUPPORT WASTE TANK QUANTITY ADJUST. 14-0088 -1D17H00M OTC CFCP PERFORM WASTE TANK QUANTITY SU72045 T-41H00M 132 ADJUST PER S0007VL4 (SEQ 54 OPTION C) TO ENSURE ENOUGH ULLAGE TO ACCEPT HUM SEP WATER TO MEET TARGETED LIFT-OFF QUANTITY FOR THIS MISSION (REF OMRS V62M0.020-B) (1 HR). NOT PERFORMED ______ 100 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LRD L-3 DAY VERIFICATIONS ------------------------- NOTE SOME LANDING SITES MAY NOT BE MANNED DUE TO MISSION REQUIREMENTS. 14-0089 -1D17H00M LRD VERIFY FOLLOWING LANDING SITES T-41HOOM LF1 MANNED TO SUPPORT LAUNCH AND NO CONSTRAINTS/OPEN ITEMS IDENTIFIED. NOT SITE GO NO GO MANNED ---- -- ----- ------ BANJUL _____ _____ _____ BEN GUERIR _____ _____ _____ ZARAGOZA _____ _____ _____ MORON _____ _____ _____ DFRF _____ _____ _____ WSSH _____ _____ _____ ET HEATER VERIF --------------- 14-0090 -1D17H00M TBC CPWR PERFORM ET HEATER VERIFICATION SU72048 T-41H00M 136 PER S0007VL4 (SEQ 72). (15 MIN) 14-0091 CECL OTC GSE/ORBITER COOLING ACTIVATION/ SU72044 132 RECONFIGURATION COMPLETE. BFS GPC LOAD/DUMP AND COMPARE ----------------------------- COMPLETE -------- 14-0092 -1D16H40M CVFS OTC BFS GPC LOAD/DUMP AND COMPARE SU72006 T-40H40M 132 COMPLETE. (SEQ 49 S0007VL4). OMRSD V72CA0.050-B OMRSD V72CA0.050-C 101 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DEU 3 DUMP/COMPARE ------------------ NOTE DO NOT PERFORM NEXT STEP UNTIL BFS GPC LOAD/DUMP AND COMPARE COMPLETE. 14-0093 OTC CODS PERFORM DEU 3 MEMORY DUMP AND SU72008 132 LPS COMPARE PER S0007VL4 (SEQ 49 ITEM 9) (5 MIN) OMRS V72CA0.010-B 14-0094 CODS OTC DEU 3 DUMP/COMPARE COMPLETE. OMRSD V72CA0.010-B FINAL PDI/DFL FOR FLIGHT ------------------------ NOTE PERFORM NEXT TWO STEPS IF PDI LOADS REQUIRED. 14-0095 -1D16H35M OTC CDPS PERFORM FINAL DFL FOR FLIGHT PER SU72011 T-40H35M 132 CISL S0007VL4 (SEQ 49 ITEM 10) (10 MIN) NOT PERFORMED ______ 14-0096 CDPS OTC FINAL PDI DFL FOR FLIGHT COMPLETE. OMRS S00FA0.301-1R NOT PERFORMED ______ 102 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TFL LOAD FOR FLIGHT ------------------- 14-0097 OTC NTD BRIEF LOSS OF OI PCM SU72014 232 DOWNLINK/DOWNLIST DATA WILL BE NTD TBC OCCURRING DURING TFL LOADS. PTC DOWNLIST FRAME COUNT ERRORS LPS MAY OCCUR. 14-0098 -1D16H25M OTC NTD SUPPORT CISL ON OIS CH 145 T-40H25M 232 FOR SEQ 49 (S0007VL4). NTD JRPS 14-0099 OTC CDPS PERFORM FINAL PCMMU TELEMETRY 132 CISL LOADS FOR FLIGHT PER S0007VL4 JISE (SEQ 49 ITEM 11) ON CH 152 CDR (30 MIN). WASTE TANK QUANTITY ADJUST COMPLETE ----------------------------------- (CONTINGENCY) ------------- NOTE PERFORM NEXT STEP IF WASTE TANK QUANTITY ADJUST PERFORMED AS PART OF COUNTDOWN. 14-0100 -1D16H00M CFCP OTC WASTE TANK QUANTITY ADJUST SU72045 T-40H00M 132 COMPLETE. (SEQ 54 OPTION C) NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF MASS SPEC HAS ALREADY BEEN REMOVED FROM MLP. 14-0101 QBSE STM MASS SPEC MACHINE REMOVAL FROM STE NET MLP CMPT 43A COMPLETE. SU72061 104 STM NTD 232 NTD OTC OTC *PAD 132 NOT PERFORMED ______ 103 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TRANSPORT COMSEC UNIT TO ORBITER -------------------------------- CAUTION DO NOT ZEROIZE KYK-26 UNITS UNLESS REQUIRED TO PROHIBIT COMPROMISING LOADED UNITS. (ZEROIZING MAY BE ACCOMPLISHED BY HOLDING DEVICE SELECTOR (MODE) SW TO Z ALL POSITION AND PRESS INITIATE/INCREMENT PUSHBUTTON SW). NOTE DO NOT PERFORM NEXT TWO STEPS IF COMSEC LOAD ALREADY PERFORMED. 14-0102 -1D16H00M OTC NTD REQUEST COMSEC CUSTODIAN COMM T-40H00M 232 TRANSPORT LOADED KYK-26 UNIT SU72136 NTD STM FROM LCC TO ORBITER MIDDECK STM GYCC AT PAD IN SECURE TRANSPORTATION 111 CASE. CUSTODIAN TO REPORT TO PAD GYCC JYVJ LEADER FOR CREW COMPARTMENT ENTRY. PTP IF GPS ENCRYPTION LOAD REQUIRED, TRANSPORT ENCRYPTION KEY. NOT PERFORMED ______ 14-0103 OTC *PAD COMSEC CUSTODIAN IS BRINGING COMSEC 132 UNIT TO PAD AND WILL REQUIRE CREW CMPT ENTRY. VERIFY CERTIFIED SCO WILL BE IN CREW CMPT FOR UNIT TURNOVER AND LOADING. NOT PERFORMED ______ 104 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TFL LOAD FOR FLIGHT COMPLETE ---------------------------- 14-0104 -1D15H55M CDPS OTC TFL LOAD FOR FLIGHT COMPLETE. SU72014 T-39H55M 132 OMRSD S00FA0.301-1R DOWNLINK FMT CHANGE (OPTIONAL) ------------------------------ NOTE PERFORM NEXT FOUR STEPS TO ACTIVATE THE LAUNCH DOWNLINK FORMAT IF LAUNCH DOWNLINK FORMAT IS NOT 129. 14-0105 OTC NTD LAUNCH DOWNLINK FORMAT ___ WILL SU72017 232 BE ACTIVATED. NTD TBC PTC NOT PERFORMED ______ 14-0106 OTC CDPS ACTIVATE LAUNCH DOWNLINK FORMAT 132 PER OMI V9001VL2 (SPECIAL INSTRUCTIONS). NOT PERFORMED ______ 14-0107 CDPS CRT (VAS59 PGB) VERIFY LAUNCH OI FMT ACTIVE NOT PERFORMED ______ 14-0108 CDPS OTC LAUNCH DOWNLINK FORMAT ___ ACTIVATED. 132 OTC NTD 232 NTD TBC PTC NOT PERFORMED ______ 105 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DDU/FLT CONT/HUD PWR UP & SELF TEST ----------------------------------- NOTE HDA WILL BE DISABLED APPROXIMATELY 10 MIN. 14-0109 -1D15H50M OTC CODS PERFORM DDU, FLIGHT CONTROL, SU72024 T-39H50M 132 AND HUD POWER UP AND SELF TEST PER S0007VL4 (SEQ 49 ITEM 12) (1 HR). REMOVE PORTABLE OIS UNITS ------------------------- NOTE PERFORM NEXT STEP WHEN SRB ESP OPS COMPLETE. UCOM/GSS TECHS MEET AT BASE OF FSS ELEVATOR. 14-0110 -1D15H30M NTD STM UCOM REMOVE FOUR (4) OF THE COMM T-39H30M 232 SIX (6) PORTABLE OIS UNITS PNSA STM GYCC FROM ZERO LEVEL OF MLP, INBOARD SU72062 111 JBPN AND OUTBOARD OF SRB FLAME HOLES. GYCC JYCD (ONE (1) UNIT TO REMAIN OUTBOARD 117 OF EACH SRB FLAME HOLE (TOTAL TWO) UNTIL COMPLETION OF SRB HPU TURBINE EXHAUST DUCT PLUG AND VENT DRAIN LINE SCRUBBER REMOVAL OPERATIONS.) INSTALL CAPS ON GOOSENECK CABLE CONNECTORS (30 MIN). GSS REMOVE PURGE FLEXHOSES ON MLP. UCOM T:______ GSS T:______ 106 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0111 JBPN STM PURGE FLEXHOSE DISCONNECTED FOR PNSA 111 REMOVAL OF FOUR OIS BOXES ON MLP. MLP ZERO LEVEL OIS UNITS REMOVED -------------------------------- 14-0112 -1D15H00M JYCD GYCC FOUR OF THE SIX PORTABLE OIS COMM T-39H00M 117 UNITS ON ZERO LEVEL OF MLP SU72062 GYCC STM INBOARD AND OUTBOARD OF SRB 111 FLAME HOLES HAVE BEEN REMOVED. STM NTD CAPS INSTALLED ON GOOSENECK 232 CABLE CONNECTORS. 14-0113 -1D15H00M CPWR TBC ET HEATER VERIFICATION COMPLETE. SU72048 T-39H00M 136 (S0007VL4 SEQ 72) MCDS OTV CAMERA REMOVAL ----------------------- NOTE PERFORM NEXT TWO STEPS IF MCDS CAMERA INSTALLED. 14-0114 -1D15H00M OTC *PAD PERFORM MCDS OTV CAMERA REMOVAL SU72041 T-39H00M 132 FROM ORBITER CREW MODULE PER: JC V33-00012 - MCDS OTV CAMERA/BRACKET AND OIS UNITS REMOVAL (30 MIN) NOT PERFORMED ______ 14-0115 -1D15H00M OTC NTD PROVIDE SUPPORT FOR REMOVAL OF COMM T-39H00M 232 MCDS OTV CAMERA AND CABLES FROM SU72070 NTD STM ORBITER CREW MODULE. STM JYVO 138 111 GYCC NOT PERFORMED ______ 107 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- COMSEC UNIT LOAD ---------------- NOTE DO NOT PERFORM NEXT TWO STEPS IF COMSEC LOAD ALREADY PERFORMED. 14-0116 CDR OTC KYK-26 UNIT HAS ARRIVED AT 132 ORBITER CREW MODULE. NOT PERFORMED ______ 14-0117 -1D15H00M OTC CCSE PERFORM COMSEC 1 AND 2 UNIT SU72110 T-39H00M 132 CDR LOADING PER OMI S9001VL2 COMM OPTIONS (1H20M). RT OMI LOG NO.__________ OMRS S00FA0.370-A-1R OMRS S00FA0.370-B-1R NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF GPS ENCRYPTION LOAD IS NOT REQUIRED. 14-0118 OTC CCSE PERFORM GPS ENCRYPTION KEY LOAD 132 PER S9001VL2. NOT PERFORMED ______ 108 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD LOAD CONTINGENCY LIGHTING ------------------------------ NOTE PERFORM NEXT STEP IF PRSD LOAD TO OCCUR AT NIGHT. 14-0119 OTC *PAD VERIFY PORTABLE FACILITY LIGHTING 132 IN PLACE FOR PRSD LOAD. NOT PERFORMED ______ HYDROGEN FIRE DETECTOR TEST --------------------------- VERIFICATION ------------ 14-0120 CHGD OTC PERFORMING HYDROGEN FIRE SU72026 132 DETECTOR TEST VERIFICATION. FIRE OTC CGSS DETECTORS WILL BE ACTIVATED CMPL MOMENTARILY. 14-0121 -1D15H00M OTC CHGD PROCEED WITH HYDROGEN FIRE DETECTOR T-39H00M 132 TEST VERIFICATION. REPORT ANY ANOMALIES. __________GMT 109 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP FOR EACH HYDROGEN FIRE DETECTOR SYSTEM: HWW14 = PADFD (LH2 HFDS) HWW15 = MLPFD (LH2 HFDS) HWW16 = EEFDS (EGR HFDS) HWW20 = FCPFD (FCP HFDS) 14-0122 CHGD CRT (SAW01/HWW14/HWW15/HWW16) VERIFY "CONF" INDICATION ON FOR EACH FIRE DETECTOR PRIMARY AND SECONDARY. CURSOR CNTL PERFORM SELF TEST COMMAND ON FOR EACH FIRE DETECTOR: STC XMIT CURSOR KEY - PRESS CRT VERIFY "ALRM" AND "SELF" INDICATION ON FOR EACH FIRE DETECTOR PRIMARY AND SECONDARY. CURSOR CNTL PERFORM SELF TEST COMMAND OFF FOR EACH FIRE DETECTOR STC XMIT CURSOR KEY - PRESS CRT VERIFY "ALRM" AND "SELF" INDICATION OFF FOR EACH FIRE DETECTOR PRIMARY AND SECONDARY. 14-0123 CHGD OTC HYDROGEN FIRE DETECTOR TEST SU72026 132 VERIFICATION COMPLETE. OTC CGSS CMPL __________ GMT 110 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DDU/FLT CONT/HUD PWR AND SELF TEST ---------------------------------- COMPLETE -------- 14-0124 -1D14H50M CODS OTC DDU, FLIGHT CONTROL AND HUD SU72024 T-38H50M 132 POWER UP AND SELF TEST COMPLETE. (SEQ 49 S0007VL4) NOTE PERFORM NEXT STEP IF MCDS CAMERA INSTALLED. 14-0125 -1D14H30M *PAD OTC MCDS OTV CAMERA AND ASSOCIATED SU72041 T-38H30M 132 BRACKET AND CABLES REMOVED FROM ORBITER CREW MODULE. NOT PERFORMED ______ 14-0126 -1D14H00M TBC *PAD PERFORM ALL SEQUENCES OF SU72057 T-38H00M 136 OMI G6304 LH2/LOX SYSTEMS PURGE *PAD PLO4 VERIFICATION. PLH4 PME4 111 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- COMSEC UNIT LOAD COMPLETE ------------------------- 14-0127 -1D14H00M CCSE OTC COMSEC UNIT LOADING PER S9001VL2 SU72110 T-38H00M 132 COMPLETE. OMRSD S00FA0.370-A-1R OMRSD S00FA0.370-B-1R 14-0128 OTC CFCP PERFORM PRSD PREPS FOR GO2/GH2 SU72009 132 CC LINE PRESSURIZATION PER OMI V1040.002. DISC OMS TRICKLE PURGE ---------------------- 14-0129 OTC *PAD DISCONNECT OMS TRICKLE PURGE PER SU72032 132 OMI V9021.002 (3 HR). 14-0130 LPS NTD SUPPORT PRE-OPERATION SETUP 232 INSTRUCTION 6 - LCC2 HSP1 LAUNCH SUPPORT CONFIGURATION COMPLETE. LPS ______ 14-0131 STM JSTC 30 MINUTE NOTIFICATION FOR FIRE 111 AT GO2/GH2 C/C PRESS. JSTC JFIR 114 NOTE DO NOT PERFORM GO2/GH2 CC LINE PRESSURIZATION IF GO2/GH2 CC LINES REMAINED PRESSURIZED FROM PREVIOUS OPERATIONS. GO2/GH2 CC LINE PRESSURIZATION ------------------------------ NOT PERFORMED ______ 112 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0132 NTD OTC VERIFY READY TO CLEAR CONTROL PNSA 232 STM AREA FOR GO2 AND GH2 BATTERY *SCC PRESSURIZATION. STM JBPN 111 JBPN GBPN | NET | 104 | | 14-0133 -1D13H00M GBPN JBPN READY TO CLEAR FOR CROSS PNSA | T-37H00M NET COUNTRY LINE PRESSURIZATION. | 104 | JBPN STM | 111 | STM NTD 232 NTD *SCC 14-0134 -1D13H00M CFCP OTC PRSD PREPS FOR CC LINE SU72009 T-37H00M 132 PRESSURIZATION COMPLETE. OTC NTD READY TO SUPPORT CROSS-COUNTRY 232 LINE REACTANT PURGE AND PRESSURIZATION PER V1040.002. 14-0135 *PSE *SCC VERIFY FIRE/RESCUE ON SITE AT FIRE NET PAD GATE AND EMERGENCY MEDICAL SU72068 105 SERVICES AVAILABLE FROM FIRE *SCC NTD STATION NO. 2 AND COMM CHECKS NTD STM WITH NTD, *SCC, AND *PSE COMPLETE 232 FOR GO2/GH2 CC LINE PRESSURIZATION. STM JSTC 111 JSTC JFIR 114 113 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLEAR FOR GO2/GH2 CROSS-COUNTRY ------------------------------- LINE PURGE PRESSURIZATION ------------------------- 14-0136 -1D13H00M NTD *SCC REQUEST FOLLOWING CONTROL AREAS SU72012 T-37H00M 232 BE CLEARED OF NONESSENTIAL *SCC *PSE PERSONNEL AND SFOC SAFETY NET CONCURRENCE TO PROCEED. 105 NONESSENTIAL PERSONNEL CLEAR: 1. GH2 BATTERIES 2. GO2 BATTERIES 3. S72-0699-1 PNL FSS 75-FT LVL (5 FT) ALL PERSONNEL CLEAR: 1. 50-FT FROM GH2 FLARE STACK 2. 50-FT FROM GH2/GO2 CROSS COUNTRY LINES VERIFY ESSENTIAL PERSONNEL ATTIRED IN NONSTATIC PRODUCING FLAME RETARDANT COVERALLS AND NONSPARKING FOOTWEAR. ESSENTIAL PERSONNEL ------------------- ORB NASA SFOC --- ---- ---- ENG/SUPV 1 1 TECHNICIAN 4 QUALITY 2 1 SAFETY 1 1 *PAD 1 *SCO 2 (GO2/GH2 FACIL) GSS PZ-A3 --------------- --- ----- ENG 1 1 TECHNICIAN 4 QUALITY 1 114 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0137 NTD ATTENTION ON PAD ___: PA ALL PERSONNEL CLEAR 50 FT FROM GH2 FLARE STACK AND 50 FT FROM GO2/GH2 CROSS-COUNTRY LINES. NONESSENTIAL PERSONNEL CLEAR 200-FT RADIUS OF GH2, 25-FT RADIUS FROM GO2 BATTERIES AND 5-FT RADIUS FROM S72-0699-1 PNL, FSS 75-FT LVL. NOTE GH2 CC LINE PURGE BY GSS SHOULD START IMMEDIATELY AFTER SAFETY CONCURRENCE TO PROCEED WITH HAZARDOUS OPERATIONS. GH2 CC LINE PRESS SHOULD START FIRST. 14-0138 -1D12H30M *PSE *SCC CONTROL AREA FOR CC LINE SU72012 T-36H30M NET REACTANT PURGE AND PRESSURIZATION 105 CLEAR OF NONESSENTIAL PERSONNEL. *SCC NTD ESSENTIAL PERSONNEL ARE PROPERLY 232 ATTIRED. YOU HAVE SAFETY CONCURRENCE NTD OTC TO PROCEED WITH PRSD GO2 AND GH2 OTC CFCP FLOW OPERATIONS AND VENTING TO 132 FLARE STACK. 14-0139 NTD ATTENTION ON PAD ___: PA VENTING TO FLARE STACK WILL OCCUR. ALL PERSONNEL REMAIN CLEAR. 14-0140 OTC CFCP PERFORM TEST TEAM BRIEFING ON HAZARDS INVOLVED AND APPLICABLE APPENDIX Z SAFING FUNCTIONS. 14-0141 OTC CHGD PERFORM LH2 HLDS/HFDS (HWW20) MONITORING. REPORT OUT OF TOLERANCE CONDITIONS TO CFCP ON OIS CH 153: HLDS = 10,000 PPM ABOVE BASELINE HFDS = ALARM ON INDICATION 115 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING HAZARDOUS OPERATION - GO2/ GH2 REACTANT PURGE FOLLOW (HAZARD IS PRESENCE OF OXYGEN AND HYDROGEN AND GO2/GH2 PRESSURIZATION). GO2/GH2 CROSS-COUNTRY LINE PURGE PRESS -------------------------------------- NOTE DO NOT PERFORM NEXT TWO STEPS IF VERIFIED PRIOR TO CALL TO STATIONS. 14-0142 -1D12H30M NTD STM PERFORM FOLLOWING: SU72015 T-36H30M 232 SU72065 STM JBPN NOTE SU72076 111 JBPN GBPN PERFORM SUBSTEP 1 IF GH2 | NET CROSS COUNTRY LINE HAS A | 104 GHE BLANKET PRESSURE. | 1. PERFORM GH2 CROSS-COUNTRY PNSA LINE PRESSURIZATION PER OPERATION INSTRUCTIONS OF M3020 AND OMI V1040.002, SEQ ___. COORDINATE WITH CFCP ON OIS CH 153 (2H00M). NOT PERFORMED ______ SS1 116 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0142 NOTE CON'T PERFORM SUBSTEP 2 IF GH2 CROSS COUNTRY LINE HAS A GH2 BLANKET PRESSURE OF 500 PSIG MAX. 2. PERFORM GH2 CROSS-COUNTRY PNSA LINE PRESSURIZATION PER OPERATION INSTRUCTIONS OF M3020. REPORT COMPLETION. NOT PERFORMED ______ SS2 3. PERFORM GO2 CC LINE PRESSURIZATION PER M3097 OPERATION INSTRUCTIONS. NOT PERFORMED ______ 14-0143 OTC CFCP ASSIST JBPN WITH GH2 CROSS- 132 COUNTRY LINE PURGE AND PRESSURIZATION PER OMI V1040.002 SEQ _____. NOT PERFORMED ______ 117 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT STEP IF VERIFIED PRIOR TO CTS. 14-0144 STM CMQC SUPPORT PRE-OPERATION SETUP 9 - 111 SRB FLAME DEFLECTOR MOVE TO LAUNCH 232 NTD POSITION COMPLETE. NTD TBC NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF VERIFIED PRIOR TO CTS. 14-0145 STM CMQC SUPPORT PRE-OPERATION SETUP STSA | 232 NTD 10 - MLP/PAD SS I/F CONNECTION AND WATER TROUGH INSTALLATION/ FILL COMPLETE. NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF VERIFIED PRIOR TO CTS. 14-0146 STM CMQC SUPPORT PRE-OPERATION SETUP 11 - 232 NTD WASHDOWNS COMPLETE. NOT PERFORMED ______ 118 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RLDS 6292 CONFIDENCE CHECKS --------------------------- 14-0147 CHGD OTC PERFORMING RLDS 6292 CONFIDENCE SU72027 132 CFCP CHECKS. IGNORE RLDS 6292 LEAK DETECTOR INDICATIONS UNTIL COMPLETION. __________GMT 14-0148 CHGD CURSOR CNTL (SAW01/HWW21) MFC POWER - ON PUMP 1 - ON PUMP 3 - ON XMIT CURSOR KEY - PRESS NOTE ALLOW A 5 MINUTE MINIMUM MFC WARMUP PRIOR TO DATA RECORDING. 14-0149 CHGD CURSOR CNTL (SAW01/HWW21) MANUAL SELECT SV1 (CAL) SV2 (CAL) SV3 (CAL) SV4 (CAL) HE Z CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT RECORD AND VERIFY PRIMARY INDICATIONS 6292A1 = __________PPM 0 +/-4000 6292A2 = __________PPM 0 +/-4000 6292A3 = __________PPM 0 +/-4000 6292A4 = __________PPM 0 +/-4000 MFC1 = __________SLPM 2.8 +/-0.5 MFC3 = __________SLPM 2.8 +/-0.5 MFC5 = __________SLPM 2.8 +/-0.5 MFC7 = __________SLPM 2.8 +/-0.5 119 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE LEAK DETECTORS SHOULD BE CONDITIONED WITH SPAN GAS AT LEAST 3 TIMES PRIOR TO DATA RECORDING. 14-0150 CHGD CURSOR CNTL (SAW01/HWW21) HE S CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT RECORD AND VERIFY PRIMARY INDICATIONS 6292A1 = __________PPM BD 6292A2 = __________PPM BD 6292A3 = __________PPM BD 6292A4 = __________PPM BD MFC1 = __________SLPM 2.8 +/-0.5 MFC3 = __________SLPM 2.8 +/-0.5 MFC5 = __________SLPM 2.8 +/-0.5 MFC7 = __________SLPM 2.8 +/-0.5 HE Z CURSOR BLOCK SUPPORT MODE XMIT CURSOR KEY - PRESS 14-0151 CHGD CURSOR CNTL (SAW01/HWW21) MFC POWER - OFF PUMP 1 - OFF PUMP 3 - OFF XMIT CURSOR KEY - PRESS 14-0152 CHGD OTC RLDS 6292 CONFIDENCE CHECKS SU72027 132 CFCP COMPLETE. NO ANOMALIES NOTED. __________ GMT 120 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PUMP HOLDING TANKS ------------------ 14-0153 STM QBSE OBTAIN HOLDING TANK DEPTH STSA | NET MEASUREMENTS (M3175). 104 REPORT DATA. EAST TANK DEPTH ______ IN. BD DATE__________ TIME__________ WEST TANK DEPTH ______ IN. BD DATE__________ TIME__________ NOTE PERFORM NEXT TWO STEPS IF LESS THAN 400,000 GALLONS CAPACITY REMAINING IN EITHER TANK, OR IF DIRECTED BY QBSE (1-0662) TO PUMP HOLDING TANK(S). 14-0154 STM QBSE PUMP HOLDING TANK(S) TO OBTAIN STSA | NET 400,000 GALLON CAPACITY MINIMUM. SU72126 104 (8 HRS) REPORT TANK DEPTHS AND VERIFY WHEN COMPLETE. NOT PERFORMED ______ 14-0155 QBSE STM HOLDING TANK PUMPING COMPLETE. STSA | NET SU72126 104 EAST TANK DEPTH ______ IN. BD DATE__________ START TIME__________ WEST TANK DEPTH ______ IN. BD DATE__________ START TIME__________ VALVES OPEN DATE__________ TIME__________ NOT PERFORMED ______ 121 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GN2 PREPS --------- NOTE PAYLOAD BAY PURGE WILL BE INTERRUPTED INTERMITENTLY FOR ECS EQUIPMENT VERIFICATIONS. 14-0156 OTC CMQC VERIFY ORBITER PRE-OPERATION SU72018 132 SETUP 10 - ECS LOCAL OPERATIONS COMPLETE. 14-0157 OTC CPVD PERFORM GN2 PREPS PER OMI V1122 SU72104 132 SEQUENCES: (2 HRS) 1. "CONTROL STATION TRANSFER, PAD TO FIRING ROOM" 2. "PREPS FOR AIR TO GN2 CHANGEOVER, OPTION A, INITIAL PREPS" 3. "CONTROL STATION TRANSFER, FIRING ROOM TO PAD" RT OMI LOG NO.__________ GH2 CC LINE PURGE/PRESSURIZATION -------------------------------- COMPLETE -------- NOTE DO NOT PERFORM NEXT THREE STEPS IF GO2/GH2 CC LINES REMAINED PRESSURIZED FROM PREVIOUS OPERATIONS. 14-0158 L-1D12H00M JBPN STM GH2 CC LINE PURGE/PRESSURIZATION PNSA T-36H00M 111 COMPLETE. CONTINUING WITH GO2 SU72065 STM NTD CC LINE PRESSURIZATION. SU72085 232 NOT PERFORMED ______ 122 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0159 CFCP OTC GH2 CC LINE PURGE/PRESSURIZATION 132 COMPLETE. GH2 VENTING TO LH2 OTC NTD FLARE STACK HAS TERMINATED. 232 REQUEST FOLLOWING AREAS BE NTD *SCC RE-OPENED FOR CONTROLLED WORK. *SCC *PSE NET 1. LH2 FLARE STACK 105 2. PERIMETER ROAD AT GH2 BATTERIES FOLLOWING CONTROLS REMAIN IN EFFECT. NONESSENTIAL PERSONNEL CLEAR: 1. GH2 BATTERIES 2. GO2 BATTERIES 3. S72-0699-1 PNL FSS 75 FT LVL (5 FT) ALL PERSONNEL CLEAR: 50 FT FROM GH2/GO2 CC LINES NOT PERFORMED ______ 14-0160 *PSE *SCC LH2 FLARE STACK AND PERIMETER NET ROAD AT GH2 BATTERIES ARE OPEN 105 FOR CONTROLLED WORK. *SCC NTD 232 NTD OTC STM TBC NOT PERFORMED ______ 123 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE WALKDOWN TO BE PERFORMED AFTER PAD SURFACE/FLAME TRENCH WASHDOWN AND PRIOR TO PAD CLEAR FOR PRSD LOADING. 14-0161 -1D12H00M NTD ATTENTION ON PAD-_____. T-36H00M PA ALL PERSONNEL SUPPORTING THE INTIAL TPS ENGINEERING DEBRIS WALKDOWN, REPORT TO THE BASE OF THE FSS IN 30 MINUTES. 14-0162 -1D11H30M NTD OTC PERFORM INITIAL TPS ENGINEERING SU72119 T-35H30M 232 STM DEBRIS WALKDOWN PER INTEGRATED *SCC OPERATIONS SUPPORT SETUP 2. OTC *PAD ADD ANY DISCREPANCIES TO 132 APPENDIX K AND NOTIFY NVM (1 HR). STM PSTM 111 *SCC *PSE NET 105 NOTE DO NOT PERFORM NEXT STEP IF VERIFIED PRIOR TO CTS. 14-0163 GBHE STM SUPPORT PRE-OPERATION SETUP - 8 HESA 111 POLE CES ASSEMBLY LIFT TO 195 FT STM CMQC LEVEL COMPLETE. NOT PERFORMED ______ 124 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FCS FIRST STOWAGE COMPLETE -------------------------- NOTE DO NOT PERFORM NEXT STEP IF FCE STOWAGE COMPLETED EARLIER. 14-0164 -1D11H00M OOCS OTC ORBITER PRE-OPERATION SETUP 21 - SU72029 T-35H00M 132 FLIGHT CREW SYSTEM FIRST STOWAGE COMPLETE. OOCS ______ NOT PERFORMED ______ REMOVE MIDDECK PLATFORMS (-35H) ------------------------------- NOTE DO NOT PERFORM NEXT TWO STEPS IF PLATFORMS HAVE BEEN PREVIOUSLY REMOVED OR IF SUPPORTING MVAK OPERATIONS. PERFORM NEXT STEP FOR OV-102/ OV-104. 14-0165 -1D11H00M OTC *PAD PERFORM A70-0558 MIDDECK SU72034 T-35H00M 132 PLATFORM REMOVAL PER: JC V66-90006 - PLATFORM ACCESS SET, A70-0558 PARTIAL MIDDECK, CREW MODULE VERTICAL, REMOVAL (2 HR) NOT PERFORMED ______ 125 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP FOR OV-103/ OV-105. 14-0166 -1D11H00M OTC *PAD PERFORM A70-0558 MIDDECK T-35H00M 132 PLATFORM REMOVAL PER: JC V66-50009 - INSTL/REM AIRLOCK OUT VERTICAL ACCESS SET- CREW MODULE (2 HR) NOT PERFORMED ______ LAUNCH PAD TOURS ---------------- NOTE PERFORM NEXT TWO STEPS IF MVAK OPERATIONS ARE SCHEDULED PRIOR TO PRSD LOAD OPERATONS. TOURS MAY BE PERMITTED ABOVE THE PAD SLOPE AT THE DISCRETION OF THE NTD. 14-0167 NTD OIC MVAK OPERATIONS READY TO COMMENCE. NET DISCONTINUE ALL TOURS ABOVE PAD SLOPE 110 FOR DURATION OF MVAK OPERATIONS. NTD 232 OTC MAY APPROVE EXCEPTIONS AS DIRECTED OTC *PAD BY THE LAUNCH DIRECTOR. 132 NOT PERFORMED ______ 14-0168 NTD OIC MVAK OPERATIONS COMPLETE. TOURS WITH NET PROPER AUTHORIZATION MAY NOW BE 110 PERMITTED ABOVE PAD SLOPE. 232 OTC OTC *PAD 132 NOT PERFORMED ______ 14-0169 *PAD OTC ORBITER OPERATION SUPPORT SETUP SU72021 132 2 - ORBITER STRUCTURAL PANEL CONFIGURATION FOR TANKING AND LAUNCH, PART A, COMPLETE. 126 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MET INITIALIZATION ------------------ 14-0170 -1D11H00M OTC CEPD PERFORM ORBITER "MET (MISSION SU72039 T-35H00M 132 CDR EVENT TIMER) INITIALIZATION AND SWITCH/CIRCUIT BREAKER CONFIGURATION" PER S0007VL4 (SEQ 50) ON CH 151 (15 MIN). 14-0171 CEPD OTC ORBITER MET INITIALIZATION AND 132 SWITCH/CIRCUIT BREAKER CONFIGURATION COMPLETE. HGDS FINAL SETUPS ----------------- NOTE DO NOT PERFORM NEXT STEP IF HGDS SETUPS COMPLETED PRIOR TO S0007. 14-0172 -1D11H00M OTC CHGD PERFORM HGDS FINAL SETUPS PER SU72574 T-35H00M 132 OMI V3540. (4 HRS) RT OMI LOG NO.__________ 1. "FINAL ENGINEERING INSPECTION (OPERATION 0010)" 2. "PRIME HGDS FINAL CONFIGURATION (OPERATION 0020)" 3. "BACKUP HGDS FINAL CONFIGURATION (OPERATION 0030)" 4. "HUMS FINAL CONFIGURATION (OPERATION 0040)" NOT PERFORMED ______ 127 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TPS DEBRIS WALKDOWN COMPLETE ---------------------------- 14-0173 -1D10H30M *PAD OTC INTEGRATED OPERATION SUPPORT SU72119 T-34H30M 132 SETUP 2 - INITIAL TPS ENGINEERING OTC NTD DEBRIS WALKDOWN COMPLETE. 232 FLT DECK PLATFORM REMOVAL ------------------------- NOTE FLIGHT DECK PLATFORM REMOVAL FOLLOWS MCDS OTV CAMERA REMOVAL. DO NOT PERFORM NEXT STEP IF FLIGHT DECK PLATFORMS HAVE PREVIOUSLY BEEN REMOVED. 14-0174 -1D10H30M OTC *PAD PERFORM FLIGHT DECK PLATFORM SU72036 T-34H30M 132 REMOVAL PER: 1. JC V66-00019 - PLATFORM ACCESS SET A70-0558 AFT FLIGHT DECK INSTALLATION/REMOVAL (1HR 30 M) 2. INSTALL SOFT COVERS OVER AFT FLT DECK. T:______ SS2 NOT PERFORMED ______ MTU OSC FREQ CHECKS ------------------- NOTE MTU MUST BE POWERED UP 12 HRS PRIOR TO NEXT STEP. 14-0175 -1D10H15M OTC CISL PERFORM MTU OSC FREQ CHECKS SU72042 T-34H15M 132 PER S0007VL4 (SEQ 38) ON OIS 232 NTD CH 145 (15 MIN). NTD JRPS 128 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0176 CISL OTC MTU OSC FREQ CHECKS COMPLETE. OMRSD V75AP0.030-1R IMU CHECKPOINT DATA READ ------------------------ NOTE DO NOT PERFORM NEXT STEP IF IMU CHECKPOINT AND I-LOAD DATA VERIFIED BY ANOTHER TOP SINCE MMU LOAD FOR S0007. 14-0177 OTC CGNC PERFORM IMU NO-POWER CHECKPOINT SU72114 132 DATA DUMP PER OMI V1123. (25 MIN) RT OMI LOG NO.__________ NOT PERFORMED ______ INSTALL OMS FLIGHT PANELS ------------------------- 14-0178 -1D10H00M *PAD OTC OMS TRICKLE PURGE DISCONNECTED. SU72032 T-34H00M 132 PROCEEDING WITH INSTALLATION SU72086 OF OMS FLIGHT PANELS (3 HR) PER: JC V80-95903 - DOOR 59-03, LH OME ENGINE SERVICE, INSTALLATION JC V80-95904 - DOOR 59-04, RH OME ENGINE SERVICE, INSTALLATION 14-0179 CPVD OTC ECS PREPS FOR AIR/GN2 CHANGEOVER SU72104 132 ARE COMPLETE (HAND VLVS CLOSED) (V1122). 129 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET LO2 LOADING PREPS -------------------- 14-0180 -1D10H00M NTD TBC PERFORM PRE-OPERATION SETUPS OF SU72055 T-34H00M 232 LO2 SYSTEM PREPS FOR VEHICLE TBC PLOX LOAD PER OMI G3151. 136 LH2 SYSTEM PRE-OP SETUPS ------------------------ 14-0181 TBC PLHY PERFORM PRE-OPERATION SETUPS PER SU72058 136 OMI G3251. OMRS S00FA0.130-1 IMU CHECKOUT DATA READ COMPLETE ------------------------------- NOTE PERFORM NEXT STEP ONLY WHEN REFERENCED TEST IS PERFORMED ON THIS RUN. 14-0182 CGNC OTC IMU CHECKPOINT DATA READ SU72114 132 COMPLETE. NOT PERFORMED ______ MADS/OEX FDM/PCM TEST --------------------- 14-0183 -1D09H30M OTC CISL PERFORM ORBITER MADS/OEX FDM/PCM SU72088 T-33H30M 132 TEST PER S0007 VL4 (SEQ 38) ON OIS CH 145 (30 MIN). OMRS V78GA0.010 OMRS V78GA0.030 130 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MADS/OEX FDM/PCM TEST COMPLETE ------------------------------ 14-0184 -1D09H00M CISL OTC ORBITER MADS/OEX FDM/PCM TEST T-33H00M 132 COMPLETE. OMRSD V78GA0.010 OMRSD V78GA0.030 PRESS CABIN AIR SYSTEM ---------------------- 14-0185 -1D09H00M OTC CECL VERIFY READY TO PRESSURIZE CABIN T-33H00M 132 AIR SYSTEM. 14-0186 OTC *PAD VERIFY VALVE A501543 ON SU72107 132 C70-1226-3 PNL IS CLOSED. T:______ 14-0187 OTC NTD VALVE A501543 ON C70-1226-3 PNSA 232 IS CLOSED (IN W/R). CONFIGURE SU72128 NTD STM CABIN AIR SYSTEM TO PRESSURIZE STM JBPN C70-1226-3 WITH 125-130 PSIG 111 BREATHING AIR FROM C70-1226-2 215 FT LVL O2/N2 SYSTEM PER OPERATION INSTRUCTIONS OF OMI M3067. (1H30M) 131 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- BREATHING AIR SAMPLE -------------------- 14-0188 OTC NTD VERIFY BREATHING AIR SAMPLED PER PNSA 232 OMI M3067 MEETS SE-S-0073 NTD STM TABLE 6.3-29 STANDARDS. PROVIDE STM JBPN COPY FOR ECLSS REVIEW. 111 RECORD ACCEPTABLE SAMPLE: STORAGE BOTTLES PRIMARY NO. __________ BACKUP NO. __________ TUBEBANK NO. __________ SAMPLE NO. __________ 14-0189 STM JBPN MAINTAIN B/A TUBE BANK AND B/A PNSA 111 SUPPLY PANEL C70-1226-1 IN HP STORAGE AREA OMI M3067. (1 HR) NOTE DO NOT PERFORM NEXT STEP IF PLATFORMS PREVIOUSLY REMOVED OR IF SUPPORTING MVAK OPERATIONS. MIDDECK PLATFORM REMOVAL COMPLETE --------------------------------- 14-0190 -1D09H00M *PAD OTC MIDDECK PLATFORM REMOVAL SU72034 T-33H00M 132 (JC V66-90006 FOR OV-102 AND OV-104) (JC V66-50009 FOR OV-103 AND 0V-105) COMPLETE. READY TO PROCEED WITH FCE STOWAGE. NOT PERFORMED ______ 132 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FCS STOWAGE POST MD PLTFM RMVL ------------------------------ NOTE DO NOT PERFORM NEXT STEP IF FCE STOWAGE COMPLETED EARLIER. 14-0191 OTC OOCS PERFORM POST MIDDECK PLATFORM SU72115 132 REMOVAL STOWAGE OPERATIONS PER OMI V5097.003 (5 HRS) OR IN CASE OF SCRUB TURNAROUND PERFORM PER FCS TPS. NOT PERFORMED ______ FLT DECK PLATFORM REMOVAL COMPLETE ---------------------------------- NOTE DO NOT PERFORM NEXT STEP IF PLATFORMS PREVIOUSLY REMOVED. 14-0192 *PAD OTC FLIGHT DECK PLATFORM REMOVAL SU72036 132 (JC V66-00019) COMPLETE. NOT PERFORMED ______ 133 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD ENGINEERING WALKTHRU ------------------------- 14-0193 OTC PRSE PERFORM PRSD ENGINEERING SU72083 132 WALKTHRU FOR CRYO LOAD PER OMI V1040.002 ORBITER OSSU 1 (1 HR). ADD ANY APPLICABLE DISCREPANCIES TO APPENDIX K AND NOTIFY NVM. WASTE MANAGEMENT STATION INSPECTION ----------------------------------- 14-0194 -1D09H00M OTC *PAD PERFORM ORBITER OPERATION SU72028 T-33H00M 132 SUPPORT SETUP 10 - WASTE MANAGEMENT STATION INSPECTION/CLOSEOUT SWITCHLIST (1 HR). WASTE MANAGEMENT STATION INSPECTION ----------------------------------- COMPLETE -------- 14-0195 -1D08H00M *PAD OTC ORBITER OPERATION SUPPORT SU72028 T-32H00M 132 SETUP 10 - WASTE MANAGEMENT STATION INSPECTION/CLOSEOUT SWITCHLIST COMPLETE. 134 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GO2 CC LINE PRESSURIZATION COMPLETE ----------------------------------- NOTE DO NOT PERFORM NEXT FOUR STEPS IF GO2/GH2 CC LINES REMAINED PRESSURIZED FROM PREVIOUS OPERATIONS. 14-0196 JBPN STM GO2 CC LINE PRESSURIZATION PNSA 111 COMPLETE. SU72015 STM NTD SU72085 232 NTD OTC OTC CFCP 132 NOT PERFORMED ______ 14-0197 NTD STM REQUEST SFOC SAFETY CONCURRENCE 232 *SCC TO RELEASE FIRE AND EMS FROM *SCC *PSE GO2/GH2 BATTERY OPERATIONS. NET 105 NOT PERFORMED ______ 14-0198 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO NET RELEASE FIRE AND EMS FROM GO2/GH2 105 BATTERY OPERATIONS. *SCC NTD 232 NOT PERFORMED ______ 14-0199 NTD STM FIRE COMBAT AND EMS RELEASED FIRE 232 FROM GO2/GH2 BATTERY OPERATIONS. SU72068 STM JSTC 111 JSTC JFIR 114 NOT PERFORMED ______ 135 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD ENGINEERING WALKTHRU COMPLETE ---------------------------------- 14-0200 PRSE OTC PRSD ENGINEERING WALKTHRU FOR SU72083 132 CRYO LOAD COMPLETE PER V1040.002 ORBITER OPERATION SUPPORT SETUP 1. PREPS FOR ORBITER/PRSD CRYO --------------------------- SERVICING AND SAMPLING ---------------------- (V1040.002 SEQ _____) --------------------- 14-0201 OTC CMQC VERIFY PRE-OPERATION SETUP 16 - SU72112 132 PRSD LOADING PREPS COMPLETE. 14-0202 -1D08H00M CFCP OTC READY TO PROCEED WITH ORBITER/ T-32H00M 132 PRSD CRYO SERVICING AND SAMPLING OTC NTD PREPS PER V1040.002 SEQ ___. 232 136 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0203 NTD *SCC REQUEST SFOC SAFETY CLEAR ALL 232 NONESSENTIAL PERSONNEL FROM *SCC *PSE FOLLOWING AREAS FOR PRSD 02/H2 NET SERVICING AND SAMPLING PREPS: 105 1. S72-0699-1 PNL/MLP INTERFACE, 75 FT LVL (5 FT) 2. FSS 155 FT LVL AND CROSSOVER 3. OMBUU 4. S72-0686-1 PNL, MLP SIDE 1, (5 FT) 5. GO2/GH2 STORAGE BATTERIES 6. NORTH BRIDGE CLEAR ALL PERSONNEL FROM FOLLOWING AREAS FOR PRSD O2/H2 SERVICING AND SAMPLING PREPS. 1. GH2 CROSS-COUNTRY LINES (50 FT) 2. LH2 FLARE STACK 3. LO2 DUMP BASIN VERIFY ESSENTIAL PERSONNEL PROPERLY ATTIRED IN CLEAN FLAME RETARDANT NON-STATIC PRODUCING COVERALLS AND NON-SPARKING FOOTWEAR AND REQUEST SAFETY CONCURRENCE TO PROCEED. ESSENTIAL PERSONNEL ------------------- ORB SFOC NASA ET --- ---- ---- -- TECH 2 2 QUAL 1 1 SAFETY 1 1 SCO 2 137 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0204 NTD ATTENTION ON PAD _____: PA ALL NONESSENTIAL PERSONNEL CLEAR FOLLOWING AREAS FOR PRSD O2/H2 SERVICING AND SAMPLING PREPS: 1. S72-0699-1 PNL/MLP INTERFACE, 75 FT LVL (5 FT) 2. FSS 155 FT LVL AND CROSSOVER 3. OMBUU 4. S72-0686-1 PNL, MLP SIDE 1, (5 FT) 5. GO2/GH2 STORAGE BATTERIES 6. NORTH BRIDGE ALL PERSONNEL CLEAR FOLLOWING AREAS FOR PRSD O2/H2 SERVICING AND SAMPLING PREPS. 1. GH2 CROSS-COUNTRY LINES (50 FT) 2. LH2 FLARE STACK 3. LO2 DUMP BASIN 14-0205 STM JBPN ORBITER PRSD CRYO SERVICING AND PNSA 111 SAMPLING PREPS IN WORK (GO2/GH2). 14-0206 PLHY TBC ET VENT LINE CONFIGURED TO SU72059 136 ACCEPT REACTANT GAS. ET LH2 TBC OTC VENT LINE PURGED WITHIN 48 HOURS 132 PER G6204 OR S1006. OTC CFCP 14-0207 OTC CHGD VERIFY SYSTEMS READY TO SUPPORT PRSD 132 LOADING PREPS. 138 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RLDS 6660 CONFIDENCE CHECKS --------------------------- 14-0208 CHGD OTC PERFORMING RLDS 6660 CONFIDENCE SU72105 132 CFCP CHECKS. IGNORE LEAK DETECTOR 29 AND 30 INDICATIONS UNTIL COMPLETION. __________GMT 14-0209 CHGD PETG COMPT 43A - AIR PURGE LINE 177 1. AIR PURGE VALVE A519390 - OPEN (CCW) 2. VERIFY AUDIBLE FLOW. T:______ 14-0210 CHGD CURSOR CNTL (SAW01/HWW13) MFC POWER - ON PUMP 1 - ON XMIT CURSOR KEY - PRESS 14-0211 CHGD CURSOR CNTL (SAW01/HWW13) MANUAL SELECT SV1 (CAL) SV2 (CAL) N2 Z CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT RECORD AND VERIFY PRIMARY INDICATIONS LD29 = __________PPM 0 +/-4000 LD30 = __________PPM 0 +/-4000 MFC1 = __________SLPM 4.0 +/-0.5 MFC3 = __________SLPM 4.0 +/-0.5 139 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE LEAK DETECTORS SHOULD BE CONDITIONED WITH SPAN GAS AT LEAST 3 TIMES PRIOR TO DATA RECORDING. 14-0212 CHGD CURSOR CNTL (SAW01/HWW13) N2 S CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT RECORD AND VERIFY PRIMARY INDICATIONS LD29 = __________PPM BD LD30 = __________PPM BD MFC1 = __________SLPM 4.0 +/-0.5 MFC3 = __________SLPM 4.0 +/-0.5 SUPPORT MODE XMIT CURSOR KEY - PRESS 14-0213 CHGD OTC RLDS 6660 CABINET CONFIDENCE SU72105 132 CFCP CHECKS COMPLETE. STOP TIME:______GMT 14-0214 OTC CHGD PERFORM LH2 AND FCP HLDS/HFDS (HWW20) 132 MONITORING. REPORT OUT OF TOLERANCE CONDITIONS TO JBPN ON OIS CH 122: HLDS = 10,000 PPM ABOVE BASELINE HFDS = ALARM ON INDICATION LD29 = 10,000 PPM ABOVE BASELINE LD30 = 10,000 PPM ABOVE BASELINE 140 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0215 *PSE *SCC ALL NONESSENTIAL PERSONNEL SU72082 NET CLEARED FROM CONTROL AREAS. 105 PERSONNEL PROPERLY ATTIRED. *SCC NTD YOU HAVE SAFETY CONCURRENCE TO 232 PROCEED WITH ORBITER/PRSD O2/H2 NTD OTC SERVICING AND SAMPLING PREPS OTC CFCP (V1040.002). 132 ALL PERSONNEL CLEARED FROM: 1. GH2 CROSS-COUNTRY LINES (50 FT) 2. LH2 FLARE STACK 3. LO2 DUMP BASIN ALL NONESSENTIAL PERSONNEL CLEARED FROM: 1. S72-0699-1 PNL/MLP I/F 75 FT LVL (5 FT) 2. FSS 155 FT LVL AND CROSSOVER 3. OMBUU 4. S72-0686-1 PNL (5 FT MLP SIDE 1) 5. GO2/GH2 STORAGE BATTERIES 6. NORTH BRIDGE WARNING HAZARDOUS STEPS FOLLOW DUE TO PRESENCE OF GO2/GH2. 14-0216 OTC CFCP BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. CABIN AIR SYS - PRESSURIZED --------------------------- 14-0217 -1D07H30M JBPN STM B/A C70-1226-2 PANEL PRESSURIZED. PNSA T-31H30M 111 SU72128 STM NTD 232 NTD OTC OTC CECL 132 14-0218 -1D07H30M JBPN STM SUPPLY PANEL C70-1226-1 AND PNSA T-31H30M 111 B/A TUBE BANK HAVE BEEN MAINTAINED. 141 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- C70-1226-3 O2 SAMPLE -------------------- 14-0219 -1D07H30M OTC CECL PERFORM (IN WHITEROOM) SU72093 T-31H30M 132 C70-1226-3 PRESSURIZATION AND O2 SAMPLE OF CABIN AIR SYSTEM PER S0007VL4 (SEQ 45 OPTION A) ON OIS CH 143 (30 MIN). NOTE PERFORM NEXT STEP IF PAYLOAD HAS UNIQUE TEMP REQUIREMENTS. 14-0220 CECL MAINTAIN RAD INLET TEMP LESS THAN FOLLOWING TEMPERATURES WHEN IN RAD FLOW (EXCURSIONS ABOVE MAXIMUM SPECIFIED VALUE ACCEPTABLE PROVIDING EXCURSIONS DO NOT EXCEED 45 MINUTES IN THREE HOURS. OMRS_ ____________ (_____DEGF) OMRS_ ____________ (_____DEGF) OMRS_ ____________ (_____DEGF) OMRS_ ____________ (_____DEGF) OMRS_ ____________ (_____DEGF) OMRS_ ____________ (_____DEGF) ECLSS ENGR____________________ NOT PERFORMED ______ ECLSS COOLING RECONFIG ---------------------- TO SUPPORT SWITCHLIST --------------------- 14-0221 -1D07H00M OTC CECL PERFORM ORBITER ECLSS COOLING SU72116 T-31H00M 132 RECONFIGURATION TO SUPPORT ASCENT SWITCHLIST PER S0007VL4 (SEQ 45 OPTION B) ON OIS CH 143 (2 HR). 142 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OMS FLT PANEL INSTL COMPLETE ----------------------------- 14-0222 -1D07H00M *PAD OTC OMS FLIGHT PANEL INSTALLATION SU72086 T-31H00M 132 COMPLETE. (JC V80-95903 AND JC V80-95904) OPERATIONS/SAFETY/FACILITY WALKDOWN ----------------------------------- 14-0223 -1D07H00M NTD OTC PERFORM INTEGRATED OPERATION SU72118 T-31H00M 232 SUPPORT SETUP 1 (PART A) - PRSD SU72127 OTC *PAD LOAD SAFETY/FACILITY/FIRE WALKDOWN 132 (1 HR). 14-0224 NTD OTC HAVE WALKDOWN PARTICIPANTS MEET FIRE 232 STM WITH PAD LEADER AT FSS ELEVATORS *SCC ON PAD SURFACE IN 30 MINUTES. OTC *PAD 132 *SCC *PSE PARTICIPANTS NET ------------ 105 STM JSTC GSE OPS 111 FACILITY OPS NET PSTM SFOC SAFETY 104 QUALITY CONTROL JSTC JFIR NASA QC 114 FIRE INSPECTOR PAD LEADER NASA SAFETY 14-0225 NTD ATTENTION ON PAD ___: PA ALL PERSONNEL SUPPORTING SAFETY/ FACILITY/FIRE WALKDOWN MEET WITH *PAD AT FSS ELEVATORS ON PAD SURFACE IN 30 MINUTES. 143 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DPS TO DOWNLIST 42 ------------------ 14-0226 -1D06H45M OTC NTD VERIFY READY FOR TRANSITION SU72090 T-30H45M 232 TO DOWNLIST FORMAT 42. NTD TBC PTC TBC ALL 136 PTC ALL 134 14-0227 TBC NTD READY TO SUPPORT TRANSITION TO PTC DOWNLIST FORMAT 42. 232 NTD OTC 14-0228 OTC ALL DPS SWITCHING TO GNC9, DOWNLIST 42 132 14-0229 OTC CDPS CONFIGURE ORBITER DPS 132 TO DL FMT 42. 14-0230 CDPS CURSOR CNTL (SAS01 PG-B) FMT 42 XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS 14-0231 CDPS CRT (VAS59 PG-B) FMT 42 ACTIVE 14-0232 CDPS OTC DPS CONFIGURED TO DL FMT 42. 132 OTC NTD 232 NTD TBC PTC TBC ALL 136 PTC ALL 134 14-0233 CECL OTC C70-1226-3 PRESSURIZATION AND SU72093 132 O2 SAMPLE OF CABIN AIR SYSTEM COMPLETE. 144 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MECHANISMS STATUS CHECKS ------------------------ NOTE MECH STATUS CHECKS REQUIRE D/L 42. 14-0234 OTC CAFM PERFORM MECHANISMS STATUS SU72095 132 CHECKS. (15 MIN) 14-0235 CAFM CDR PANEL MA73C ROW A MCA LOGIC MN A FWD 1 SW - ON MID 1 SW - ON MN B FWD 2 SW - ON MID 1 SW - ON MID 2 SW - ON MN C FWD 3 SW - ON MID 2 SW - ON ROW B MCA LOGIC MN A AFT 1 SW - ON MID 3 SW - ON MN B AFT 2 SW - ON MID 3 SW - ON MID 4 SW - ON MN C AFT 3 SW - ON MID 4 SW - ON 145 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0236 CAFM OTC VERIFY FORMAT 129/42 OR 166/42 MECHANISMS STATUS CHECKS. 14-0237 CAFM CDR PANEL L4 ROW P AC2 LG SNSR 2 PH A CB - CLOSE AC3 LG SNSR 1 PH A CB - CLOSE 14-0238 OTC CAFM PROCEED WITH STATUS CHECKS. 132 14-0239 CAFM CRT (VAK20) PERFORM MECHANISMS STATUS CHECKS. 14-0240 CAFM PROGRAM VAK20 USING PROGRAM - STATUS MECH SYSTEMS (ALL OPERATIONAL STATUS UP ARROWS). IF ANY OPER STAT ARROWS NOT UP - HAVE OTC POLL OTHER USERS OF MCA OP STAT'S FOR ANY ACTIVITY (HARD COPY) XMIT CURSOR FOR MCA SNAPSHOT. VERIFY ALL UP ARROWS. 14-0241 CAFM OTC MECHANISM STATUS CHECKS COMPLETE. 132 FORMAT 129/42 OR 166/42 NO LONGER REQUIRED FOR MECHANISMS. 146 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONTROLLER AND SWITCH TESTS --------------------------- NOTE CONTROLLER AND SWITCH TESTS ARE ONLY REQUIRED ONE TIME PRIOR TO LAUNCH, MAKING REPEAT OF TESTS OPTIONAL FOR A RECYCLE LAUNCH COUNTDOWN. DO NOT PERFORM THESE TESTS IF THEY HAVE BEEN PERFORMED IN PREVIOUS COUNTDOWN UNLESS THERE IS CONCERN OVER ACTIVITY IN THE GENERAL LRU AREA OR CONCERN OVER POSSIBLE TREND DATA OR CONCERN OVER THE TIME ELASPED SINCE LAST TEST. THE FOLLOWING ARE INDEPENDENT OPERATIONS AND MAY BE PERFORMED IN ANY ORDER. DDU 1, 2 AND 3 POWER IS REQUIRED FOR THE CONTROLLER TEST. DL FORMAT 42 IS REQUIRED FOR BOTH CONTROLLER AND THE RHC PANEL SWITCH TESTS. THE ABORT SWITCH TEST IS INDEPENDENT OF FORMAT (LDB READS). 14-0242 -1D06H30M OTC COFC PERFORM CONTROLLER AND SWITCH SU72092 T-30H30M 132 TESTS PER OMI V1123. 1. CONTROLLER TEST (30 MIN) (CDR). 2. ABORT/RHC PANEL SWITCH TEST (20 MIN) (CDR). RT OMI LOG NO.__________ OMRS S00FA0.940-1R NOT PERFORMED ______ 147 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OI SNAPSHOT ----------- 14-0243 -1D06H30M NTD JRPS PERFORM OI SNAPSHOT (2 COPIES). SU72097 T-30H30M 232 CONFIG TUBE BANK ---------------- NOTE PERFORM NEXT TWO STEPS IF CABIN AIR TUBE BANK BELOW 1100 PSI. 14-0244 -1D06H30M STM JSTC PROVIDE FULL TUBE BANK PN T-30H30M 111 B/A TO CABIN AIR BATTERY. SU72130 JSTC GSPS REMOVE DEPLETED TUBE BANK. NET 104 QV:_____ QA NOT PERFORMED ______ 14-0245 STM JBPN DISCONNECT/CONNECT T/B AT O2/N2 PNSA 111 CABIN AIR BATTERY PER OPERATION INSTRUCTIONS OF OMI M3067. NOT PERFORMED ______ 148 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE GPS ACTIVATION, ALMANAC COLLECTION AND NAVAIDS ACTIVATION AND SELF TEST MAY BE PERFORMED IN PARALLEL. GPS ACTIVATION AND ALMANAC COLLECTION ------------------------------------- NOTE DO NOT PERFORM GPS ACTIVATION AND ALMANAC COLLECTION FOR OV-102. 14-0246 NTD OTC PERFORM GPS ACTIVATION AND SU72151 232 ALMANAC COLLECTION (S0007VL4 SEQ 37) OTC CNSE ON CH 173. 132 NOT PERFORMED ______ 149 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PREP FOR NAVAIDS ACT/SELF TEST ------------------------------ NOTE DO NOT PERFORM NEXT EIGHT STEPS IF NAVAIDS SELF TEST WAS ALREADY PERFORMED DURING PRESENT FLOW, UNLESS ENGINEERING EVALUATION SUGGESTS THAT REPERFORMANCE WILL ADD SIGNIFICANT CONFIDENCE IN FLIGHT READINESS. 14-0247 OTC CMQC VERIFY ORBITER PRE-OPERATION 132 SETUP 23 - TACAN SIGNAL MONITOR SETUP - C&T STATION COMPLETE. NOT PERFORMED ______ 14-0248 -1D06H30M NTD STM VERIFY OPEN LOOP FREQUENCY SU72129 T-30H30M 232 CLEARANCE FOR FOLLOWING STM ENDO FREQUENCIES FROM T-30 HRS UNTIL 111 T+2 HOURS. (853-2436/5941) 1. MSBLS - 15.460, 15.616 AND 15.568 GHZ (KU-BAND) 2. RADAR ALTIMETER MC409-0015-0006 NOT PERFORMED ______ 14-0249 NTD STM PERFORM FOLLOWING: SU72131 232 STM GYCC 1. VERIFY KSC TACAN STATION COMM 111 GEMA SUPPORTING AND PERSONNEL GYCC FTAC ON STATION TO PERFORM 117 TRANSPONDER SWITCHOVER PER OMI Z3D00 (SEQ 7). 2. REPORT WHICH TRANSPONDER CURRENTLY ACTIVE. TRANSPONDER NO.______ (1 OR 2) 3. SUPPORT NAVAIDS ACTIVATION TEST PER S0007VL4, SEQ 37, ON OIS CH 173. (GEMA - 7-3192) NOT PERFORMED ______ 150 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NAVAIDS ACTIVATION CLEARING --------------------------- 14-0250 CNSE OTC READY TO PROCEED WITH NAVAIDS SU72099 132 *PAD ACTIVATION/SELF TEST. REQUEST SU72150 OTC NTD SAFETY CLEAR ALL PERSONNEL 232 8 IN. FROM ORBITER NAVAIDS NTD *SCC ANTENNA ON RSS 207 FT LEVEL. *SCC *PSE NET 105 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF MONITOR REQUIRED IN FRCS ROOM. 14-0251 -1D06H30M OTC *PAD REQUEST ANTENNA MONITOR REPORT T-30H30M 132 ON STATION IN FRCS ROOM TO *PAD PCST SUPPORT NAVAIDS ACTIVATION. NOT PERFORMED ______ 14-0252 -1D06H30M NTD ATTENTION ON PAD ___: T-30H00M PA ALL PERSONNEL STAND 8 IN. CLEAR OF ORBITER NAVAIDS ANTENNA ON RSS 207 FT LEVEL. NOT PERFORMED ______ 151 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NAVAIDS ACTIVATION/SELF TEST ---------------------------- 14-0253 -1D06H00M *PSE *SCC SAFETY WARNING SIGNS IN PLACE. SU72099 T-30H00M NET ALL PERSONNEL CLEAR OF NAVAIDS 105 ANTENNAS (OR) MONITOR ON STATION. *SCC NTD YOU HAVE SAFETY CONCURRENCE TO 232 PROCEED WITH NAVAIDS ACTIVATION. NTD OTC NOT PERFORMED ______ WARNING HAZARDOUS OPERATION - NAVAIDS ACTIVATION FOLLOWS. (HAZ DUE TO RF RADIATION FROM NAVAIDS ANTENNAS). 14-0254 -1D06H00M OTC CNSE PERFORM ACTIVATION/SELF TEST SU72101 T-30H00M 132 CDPS AND DEACTIVATION OF NAVAIDS COMPONENTS PER S0007VL4 (SEQ 37) ON OIS CH 173 (2 HR). NOT PERFORMED ______ 14-0255 -1D06H00M JRPS NTD OI SNAPSHOT COMPLETE. SU72097 T-30H00M 232 NTD OTC 152 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NAVAIDS CIRCUIT BREAKER CLOSING IF NAVAIDS ACTIVATION AND SELFTEST (IN S0007 VL4) WILL NOT BE PERFORMED DURING THIS RUN OF S0007. NAVAIDS CIRCUIT BREAKER CLOSING ------------------------------- NOT PERFORMED ______ 14-0256 CNSE CDR PANEL O7 TACAN 1 MODE SW - OFF TACAN 2 MODE SW - OFF TACAN 3 MODE SW - OFF 14-0257 CNSE CDR PERFORM FOLLOWING: 1. IF GOULD TACAN 1 INSTALLED: PANEL L4 ROW P AC1 TACAN 1 PH C CB - CLOSE NOT PERFORMED ______ SS1 2. IF COLLINS TACAN 1 INSTALLED: PANEL O14 ROW C MNA TACAN 1 CB - CLOSE NOT PERFORMED ______ SS2 3. IF GOULD TACAN 2 INSTALLED: PANEL L4 ROW P AC2 TACAN 2 PH C CB - CLOSE NOT PERFORMED ______ SS3 153 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0257 4. IF COLLINS TACAN 2 INSTALLED: CON'T PANEL O15 ROW C MNB TACAN 2 CB - CLOSE NOT PERFORMED ______ SS4 5. IF GOULD TACAN 3 INSTALLED: PANEL L4 ROW P AC3 TACAN 3 PH C CB - CLOSE NOT PERFORMED ______ SS5 6. IF COLLINS TACAN 3 INSTALLED: PANEL O16 ROW C MNC TACAN 3 CB - CLOSE NOT PERFORMED ______ SS6 14-0258 CNSE CDR PANEL O8 MLS 1,2,3 SW - OFF 14-0259 CNSE CDR PANEL O8 RADAR ALTIMETER 1,2 SW - OFF RADAR ALTIMETER CB ------------------ 14-0260 CNSE CDR PANEL O14 ROW E MNA RADAR ALTM 1 CB - CLOSE (GUARDED) PANEL O15 ROW E MNB RADAR ALTM 2 CB - CLOSE (GUARDED) 154 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0261 CNSE CDR PANEL O14 ROW E MNA MLS 1 CB - CLOSE (GUARDED) PANEL O15 ROW E MNB MLS 2 CB - CLOSE (GUARDED) PANEL O16 ROW E MNC MLS 3 CB - CLOSE (GUARDED) NOTE PERFORM NEXT TWO STEPS FOR OV-102. 14-0262 CNSE CDR PANEL O14 ROW D MN A GPS PREAMPL UC CB - OPEN LC CB - OPEN NOT PERFORMED ______ 14-0263 CNSE CDR PANEL O16 ROW D MN C GPS PREAMPL UC CB - OPEN LC CB - OPEN NOT PERFORMED ______ 155 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT TWO STEPS FOR OV-103, OV-104 AND OV-105. 14-0264 CNSE CDR PANEL O14 ROW D MN A GPS PREAMPL UC CB - OPEN LC CB - CLOSE NOT PERFORMED ______ 14-0265 CNSE CDR PANEL O16 ROW D MN C PREAMPL UC CB - CLOSE LC CB - OPEN NOT PERFORMED ______ NAVAIDS CIRCUIT BREAKER CLOSING COMPLETE ---------------------------------------- 156 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- C & T STATION SETUP ------------------- NOTE PERFORM NEXT STEP IF C & T STATION NO. 1 (BAY 1&2) IS SUPPORTING LAUNCH COUNTDOWN. 14-0266 OTC RCRT PERFORM OMI V3528.001, OPERATION SU72102 132 SUPPORT SETUPS 12 AND 25, C & T STATION INITIALIZATION (PAD OPTION). REPORT COMPLETION. RT OMI LOG NO.__________ NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF C & T STATION NO. 2 (BAY 3) IS SUPPORTING LAUNCH COUNTDOWN. 14-0267 OTC RCRT PERFORM OMI V3528.002, SU72102 132 OPERATIONS SUPPORT SETUPS 12 AND 25, C & T STATION INITIALIZATION (PAD OPTION). REPORT COMPLETION. RT OMI LOG NO.__________ NOT PERFORMED ______ 157 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- C & T STATION/MILA COMSEC KEYS LOADED ------------------------------------- 14-0268 -1D06H00M OTC NTD VERIFY ORBITER COMPATIBLE COMSEC COMM -30H00M 232 KEYS HAVE BEEN LOADED PER SU72134 NTD STM SUPPORT PRE-OPERATION SETUP 7 - STM GYCC COMMUNICATION SUPPORT IN C&T 111 STATION 1/2, AS SCHEDULED AND GYCC JYVJ MILA COMSEC BOXES. PTP RECORD C&T STATION LOADED:__________ 14-0269 OTC RCRT PERFORM COMSEC LOAD VERIF PER 132 OMI V3528.001 OR OMI V3528.002. REPORT COMPLETION. RT OMI LOG NO.__________ 14-0270 STM JBAC C-2 VERIFY FOLLOWING ARE HVAA 111 PRESSURIZED WITH AIR: FSS ELEV MACH ROOM RSS ELEV AND HOIST MACH ROOM (M3034) 14-0271 *PAD TBC ALL SEQUENCES OF G6304- SU72057 136 LOX/LH2 SYSTEMS PURGE VERIFICATION - COMPLETE. CONTROLLER AND SWITCH TEST -------------------------- COMPLETE -------- NOTE PERFORM NEXT STEP ONLY IF REFERENCED TESTS HAVE BEEN PERFORMED ON THIS RUN. 14-0272 -1D05H40M COFC OTC CONTROLLER AND SWITCH TEST SU72092 T-29H40M 132 COMPLETE. OMRSD S00FA0.940-1R NOT PERFORMED ______ 158 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NWS VERIFICATION FOR COUNTDOWN ------------------------------ NOTE THE NWS TEST IS REQUIRED ONE TIME PRIOR TO LAUNCH, MAKING THE REPEAT OF THE TEST OPTIONAL FOR A RECYCLE LAUNCH COUNTDOWN. DO NOT PERFORM THIS TEST IF IT HAS BEEN PERFORMED IN THE PREVIOUS COUNTDOWN UNLESS THERE IS CONCERN OVER ACTIVITY IN THE GENERAL LRU AREA OR CONCERN OVER POSSIBLE TREND DATA OR CONCERN OVER TIME ELAPSED SINCE LAST TEST. NEXT STEP REQUIRES DDU2 POWER AND DL FMT 42. 14-0273 -1D05H40M OTC COFC PERFORM NWS VERIFICATION FOR SU72094 T-29H40M 132 COUNTDOWN PER OMI V1123. (25MIN - CDR). RT OMI LOG NO.__________ NOT PERFORMED ______ INSPECTION OF MIDDECK COMPLETE ------------------------------ 14-0274 -1D05H30M *PAD OTC INSPECTION OF CREW MODULE SU72109 T-29H30M 132 INTERIOR MIDDECK PER ORBITER PRE-OPERATION SETUP 11 COMPLETE. 159 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GPS ACTIVATION AND ALMANAC COLLECTION ------------------------------------- COMPLETE -------- NOTE PERFORM NEXT STEP IF GPS ACTIVATION AND ALMANAC COLLECTION WERE PERFORMED. 14-0275 -1D05H15M CNSE OTC GPS ACTIVATION AND ALMANAC SU72151 T-29H15M 132 COLLECTION COMPLETE. OTC NTD 232 NOT PERFORMED ______ NWS VERIFICATION COMPLETE ------------------------- NOTE PERFORM NEXT STEP ONLY IF THE REFERENCED TEST HAS BEEN PERFORMED ON THIS RUN. 14-0276 -1D05H15M COFC OTC NWS VERIFICATION FOR COUNTDOWN SU72094 T-29H15M 132 COMPLETE. NOT PERFORMED ______ 160 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MLP PRESSURIZATION ------------------ NOTE DO NOT PERFORM NEXT FOUR STEPS IF MLP PRESSURIZATION REMAINS IN EFFECT FROM PREVIOUS OPERATIONS. 14-0277 -1D05H00M NTD ATTENTION ON MLP: T-29H00M PA 1. MLP WILL BE PRESSURIZED WITH AIR 2. ALL PERSONNEL ENTERING OR EXITING MLP MUST USE AIR LOCK AT SIDE 2, B LEVEL. 3. UTILIZE CAUTION WHEN ENTERING OR EXITING THRU AIR LOCK. 4. PRESSURIZATION OF MLP MAY ACTIVATE MLP FIRE ALARMS. DISREGARD FIRE ALARM BELLS AND BEACONS. IN CASE OF FIRE DIAL 911. NOT PERFORMED ______ 14-0278 NTD JFIR MLP IS BEING PRESSURIZED. IF FIRE 232 FIRE ALARM ACTIVATED, PERFORM THREE RESETS BEFORE DISPATCHING RESCUE. NOT PERFORMED ______ 14-0279 NTD OTC MLP BEING PRESSURIZED. ALL 232 TBC PERSONNEL ENTERING OR EXITING *SCC MLP MUST EXERCISE CAUTION AND OTC *PAD USE B LEVEL, SIDE 2 AIR LOCKS. 132 NOT PERFORMED ______ 14-0280 NTD STM PRESSURIZE MLP WITH AIR PER HVAA 232 OMI M3079. SU72135 STM JBAC 111 NOT PERFORMED ______ 161 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OI PCM'S TO GSE CONTROL ----------------------- 14-0281 OTC CISL PERFORM OI PCM TO GSE SU72091 132 CONTROL PER S0007VL4 (SEQ 38) (5 MIN) 14-0282 CISL OTC OI PCM TO GSE CONTROL COMPLETE. 132 OMRSD V75AP0.010-1R NOTE PERFORM NEXT STEP IF PRE-OPERATION SETUP 22 WAS PERFORMED. 14-0283 COOS OTC ORBITER PRE-OPERATION SETUP 22 - SU72098 132 OME GN2 REG OUT ADJUSTMENT COMPLETE. NOT PERFORMED ______ ECLSS COOLING RECONFIG COMPLETE ------------------------------- 14-0284 CECL OTC ECLSS COOLING RECONFIG TO SU72116 132 SUPPORT INGRESS SWITCH LIST (SEQ 45 S0007VL4) COMPLETE. CONFIG AC BUS SENSORS --------------------- NOTE DO NOT PERFORM NEXT STEP IF AC BUS SENSORS ARE ALREADY IN MONITOR. 14-0285 -1D04H45M OTC PLT PANEL R1 SU72171 T-28H45M 132 POWER DISTRIBUTION AC BUS SNSR 1 SW - OFF, 1 SEC THEN MONITOR 2 SW - OFF, 1 SEC THEN MONITOR 3 SW - OFF, 1 SEC THEN MONITOR NOT PERFORMED ______ 162 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PIC RACK CB CONFIGURE --------------------- NOTE PERFORM NEXT FOUR STEPS IF SHUTTLE PIC RESISTANCE TEST IS TO BE PERFORMED. 14-0286 OTC CEPD PERFORM PIC RACK CB SU72096 132 CONFIGURATION. NOT PERFORMED ______ 14-0287 CEPD QPDS RACK 6814 (COMPT 7A) 151 22D170 (LH2 BURN PIC) CB - ON (CLOSED) RACK 6820 22D260 (LR PIC) CB - ON (CLOSED) RACK 6823 22D280 (LH2 BURN PIC) CB - ON (CLOSED) RACK 6815 22D330 (LR PIC) CB - ON (CLOSED) T:______ NOT PERFORMED ______ 14-0288 OTC CEPD CLEAR ALL PDS TECHNICIANS FROM SU72100 132 MLP AND PTCR. NOT PERFORMED ______ 14-0289 CEPD OTC PDS TECHS ARE CLEARING MLP AND 132 PTCR. OTC NTD 232 NOT PERFORMED ______ 163 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OPERATIONS/FACILITY WALKDOWN PART B - ------------------------------------- LC-39 PERIPHERY WALKDOWN ------------------------ 14-0290 NTD OTC PERFORM INTEGRATED OPERATION SU72120 232 SUPPORT SETUP 1 - OPERATION/ SU72132 OTC *PAD FACILITY WALKDOWN PART B - 132 LC-39 PERIPHERY WALKDOWN. 14-0291 NTD NPM HAVE INTEGRATED WALKDOWN FIRE 232 STM PARTICIPANTS MEET WITH *PAD OTC AT FSS ELEVATORS ON PAD SURFACE OTC *PAD UNDER DIRECTION OF PAD LEADER 132 IN 30 MINUTES. NASA OPS (NPM) FACILITY OPS PAD LEADER NOTE DO NOT PERFORM NEXT STEP IF PART A AND B WALKDOWNS WILL BE PERFORMED AT THE SAME TIME. 14-0292 NTD ATTENTION ON PAD___: PA ALL PERSONNEL SUPPORTING LC-39 PERIPHERY WALKDOWN MEET WITH *PAD AT FSS ELEVATORS ON PAD SURFACE IN 30 MINUTES. NOT PERFORMED ______ 164 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- COMPLETION OF SECOND FCE STOWAGE -------------------------------- NOTE DO NOT PERFORM NEXT STEP IF FCE STOWAGE COMPLETED EARLIER. 14-0293 -1D04H00M OOCS OTC STOWAGE AFTER MIDDECK PLATFORM SU72115 T-28H00M 132 REMOVAL COMPLETE. NOT PERFORMED ______ GTOE HEADSET DELIVERY AND INSTL ------------------------------- NOTE PERFORM NEXT STEP AFTER FLT CREW SYSTEMS HAS INSTALLED CABLES AND HIU'S PER V5097.003. 14-0294 -1D04H00M OTC CDR PERFORM ORBITER OPERATION SU72087 T-28H00M 132 SUPPORT SETUP 11 - GTOE HEADSET DELIVERY AND INSTALLATION. (30 MIN) MLP PRESSURIZATION COMPLETE --------------------------- NOTE DO NOT PERFORM NEXT THREE STEPS IF MLP PREVIOUSLY PRESSURIZED. 14-0295 -1D04H00M JBAC STM MLP PRESSURIZED FOR PRSD CRYO HVAA T-28H00M 111 LOAD AND "PRESSURIZED" SIGNS SU72135 STM NTD POSTED. 232 NOT PERFORMED ______ 14-0296 NTD JFIR MLP PRESSURIZATION COMPLETE. FIRE ACKNOWLEGE MLP FIRE ALARM ANNUNCIATIONS AS VALID. NOT PERFORMED ______ 165 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0297 NTD ATTENTION ON MLP PAD ____: PA MLP PRESSURIZATION COMPLETE. RESPOND TO ALL MLP FIRE ALARM BELLS AND BEACONS. NOT PERFORMED ______ 14-0298 NTD LPS VERIFY (AWP05 PGB PAD A OR AWP06 232 PGB PAD B) HIMS 5982, 5987, 6377 LPS C1MC AND 6378 DISPLAYED IN MIXED MODE. SET UP BADGE BOARD FOR HAZ -------------------------- BADGES (PRSD CRYO LOAD) ----------------------- NOTE NEXT STEP WILL BE SCHEDULED REAL TIME SO THAT THE BADGE BOARD IS SET UP PRIOR TO SHIFT CHANGE. 14-0299 NTD OTC SET UP BADGE BOARD AT PAD ___ SU72111 232 GATE FOR PRSD TANKER PLACEMENT, OTC *PAD ECS AIR TO GN2 CHANGEOVER AND 132 ORBITER PRSD LOADING. *PAD *ACM NET 110 166 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0300 *ACM FOLLOWING PERSONNEL REQUIRED TO NET SUPPORT AIR TO GN2 CHANGEOVER 110 AND CRYO LOAD. ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- (TANKER PLACEMENT/CRYO LOAD) ---------------------------- NOTE MANLOADED CHANGEOUT CREWS WILL BE STAGED IN SCAPE TRAILERS. SFOC NASA JBOSC ---- ---- ----- ENGR 2 1 2 TECH 6 4 QC 4 2 SAF 1 1 ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- (AIR TO GN2 CHANGEOVER) ----------------------- SFOC NASA ---- ---- ENGR 1 1 ECS TECH 4 QC SAFETY 1 1 ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- (PTCR/ECS ROOM PRESS.) ---------------------- GSS NASA SFOC --- ---- ---- SAFETY 1 1 SUPR/ENG 2 TECH 2 QUAL 1 167 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0300 ESSENTIAL PERSONNEL (HAZ BADGE) CON'T ------------------------------- (CREW MODULE & WHITE ROOM) -------------------------- SFOC ---- SCO 2 OIC 1 NAVAIDS ACT/SELF TEST - COMPLETE -------------------------------- NOTE PERFORM NEXT FOUR STEPS IF NAVAIDS SELF TEST WAS PERFORMED. THE FOLLOWING REQUIREMENTS CAN BE SATISFIED IN S0007VL4 IF THEY HAVE NOT ALREADY BEEN SATISFIED DURING THE OPF FLOW. 14-0301 -1D04H00M CNSE OTC NAVAIDS ACTIVATION/SELF TEST SU72101 T-28H00M 132 *PAD AND DEACTIVATION COMPLETE. CHECK REQUIREMENT(S) PERFORMED IN S0007VL4 AND N/A REQUIREMENT NOT PERFORMED. (SEQ 37 S0007VL4) OMRSD V74AB0.102-1R (BLANKING AT PAD) OMRSD V74AB0.190-1R____(TAC GROUND I/F CHECK) OMRSD V74AB0.020-1R____(TACAN SELF TEST) OMRSD V74AC0.011-1R____(RALT PWR ON VERIF) OMRSD V74AC0.020-1R____(RALT SELF TEST) OMRSD V74AD0.020-1R____(MLS SELF TEST) NOT PERFORMED ______ 168 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE HAZARDOUS OPERATION - NAVAIDS RADIATION COMPLETE. 14-0302 OTC NTD NAVAIDS DEACTIVATION COMPLETE. SU72150 232 REQUEST SAFETY OPEN RSS 207 FT NTD *SCC LEVEL FOR CONTROLLED WORK. *SCC *PSE NET 105 NOT PERFORMED ______ 14-0303 *PSE *SCC RSS 207 FT LEVEL OPEN NET FOR CONTROLLED WORK. 105 *SCC NTD 232 NTD OTC OTC *PAD 132 CNSE NOT PERFORMED ______ 14-0304 NTD STM TACAN GROUND STATION SUPPORT COMM 232 MAY BE RELEASED AT THIS TIME. STM GYCC 111 GYCC FTAC 117 NOT PERFORMED ______ CONFIGURE CCF-39 GN2 PRODUCTION ------------------------------- PLANT FOR LPGN2 --------------- 14-0305 -1D04H00M STM JSTC NOTIFY CCF-39 GN2 PRODUCTION PNU T-28H00M 111 PLANT LPGN2 HIGH FLOW RATE WILL SU72133 JSTC GSPN BE REQUIRED IN 4 HOURS FOR AIR 114 TO GN2 CHANGEOVER. 169 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CANTILEVER/JIB HOIST REMOVAL ---------------------------- NOTE PERFORM NEXT TWO STEPS IF CANTILEVER/JIB HOISTS INSTALLED. 14-0306 JBWC STM INSTALLATION OF SS SPOOL PIECES WSSA 111 COMPLETE. CANTILEVER/JIB HOIST STM NTD MAY BE REMOVED AT THIS TIME. NTD TBC 232 NOT PERFORMED ______ 14-0307 1D04H00M TBC *PAD REMOVE CANTILEVER/JIB HOIST SU72122 T-28H00M 136 ASSEMBLIES PER OMI B5150. *PAD PBOL NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF PERFORMED BY ANOTHER DOCUMENT. 14-0308 STM QBSE INSTALL SRB HYDRAULIC AND STSA | NET PNEUMATIC DECK PLATES. 104 VACUUM/BRUSH CLEAN DECK WELLS AND SEALS BEFORE SETTING COVER PLATES. T:______ NOT PERFORMED ______ 14-0309 PBOL *PAD SRB PRE-OPERATION SETUP 3 - SU72123 *PAD TBC QUALITY WALKDOWN COMPLETE. 136 VERIFY FACILITITES PRESSURIZED ------------------------------ 14-0310 -1D04H00M *SCC NTD VERIFY MLP, FSS - EMR, RSS T-28H00M 232 - HMR AND EMR ARE PRESSURIZED NTD STM WITH AIR. 170 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0311 *SCC NTD VERIFY PCR PRESSURIZED WITH AIR 232 NTD OTC OTC PPVM 132 14-0312 STM NTD MLP, FSS-EMR, RSS-HMR AND EMR ARE 232 PRESSURIZED WITH AIR. NTD *SCC 14-0313 OTC NTD PCR PRESSURIZED WITH AIR. 232 NTD *SCC SECURE PAD SURFACE OIC MONITOR ------------------------------ SHACK ----- 14-0314 -1D04H00M NTD OTC AT OIC MONITOR SHACK ON PAD SU72103 T-28H00M 232 SURFACE DISCONNECT POWER PLUG OTC *PAD FROM FACILITY POWER AND TAG 132 PLUG 'DO NOT USE'. REPORT COMPLETION. 14-0315 NTD STM LOCKOUT PAD SURFACE OIC COMM 232 MONITOR SHACK ADMIN TELEPHONE SU72142 STM GYCC IN PTCR RM 203. 111 (PAD A - 861-1151, SW 5; GYCC JYCJ PAD B - 861-1152, SW 9) 117 REPORT COMPLETION. SERVICE PAD AIR COMPRESSORS --------------------------- 14-0316 -1D04H00M STM JBPN SERVICE PAD AIR COMPRESSORS PER PNSA T-28H00M 111 OMI M3022 (1 HR). SU72139 MPS FINAL PREPS COMPLETE ------------------------ 14-0317 -1D04H00M CMPS OTC MPS FINAL PREPS PER V9018.001 T-28H00M 132 COMPLETE. 171 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- HOLD TIME REMAINING CLOCK MANAGEMENT ------------------------------------ 14-0318 -1D04H00M NTD STM PROGRAM "HOLD TIME REMAINING CLOCK" T-28H00M 232 (TIMER #5) FOR FOLLOWING TIMES: STM JTCR 111 1. T-27 HR HOLD _____HRS_____MIN_____SEC 2. T-19 HR HOLD _____HRS_____MIN_____SEC 3. T-11 HR HOLD _____HRS_____MIN_____SEC 4. T-6 HR HOLD _____HRS_____MIN_____SEC NOTE DATA FOR T-3 HR HOLD WILL BE TWO HRS NOMINAL. 5. T-3 HR HOLD _____HRS_____MIN_____SEC NOT PERFORMED ______ SS5 6. T-20 MIN HOLD _____HRS_____MIN_____SEC 7. T-9 MIN HOLD _____HRS_____MIN_____SEC CLOCK SHOULD STOP AT ZERO FOR T-27, T-19, T-11, T-6, T-3 HR HOLDS. CLOCK SHOULD CONTINUE PLUS COUNT FOR T-20 AND T-9 MIN HOLDS. NTD WILL NOTIFY JTCR ON OIS 178 FOR ADJUSTMENTS FROM T-9 MIN HOLD IF REQUIRED. 172 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0319 NTD STM IF AFT CLOSED FOR FLIGHT AND PWRA | 232 IF NOT ALREADY PERFORMED, | STM JBEP CONFIGURE PAD ORBITER AFT 111 OXYGEN ANALYZER FOR LAUNCH PER OMI M3088. REPORT COMPLETION. NOT PERFORMED ______ 14-0320 NTD STM PERFORM INSPECTION OF WR/CREW PWRA | 232 CABIN AND ORBITER AFT ODMS | STM JBEP ENCLOSURES. VERIFY ENCLOSURE 111 DOORS SECURELY CLOSED FOR LAUNCH. OPERATIONS/SAFETY/FACILITY WALKDOWN ----------------------------------- (PART A) COMPLETE ----------------- 14-0321 -1D04H00M *PAD OTC INTEGRATED OPERATION SUPPORT SU72118 T-28HOOM 132 SETUP 1 (PART A) - PRSD LOAD OTC NTD SAFETY/FACILITY/FIRE WALKDOWN 232 STM COMPLETE. *SCC 14-0322 *PAD OTC AFT CLOSEOUT COMPLETE. READY 132 TO PROCEED WITH OIC MONITOR OTC NTD SHACK REMOVAL. 232 NTD STM *SCC *SCC *PSE NET 105 173 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 135 FT LEVEL OIC MONITOR SHACK ------------------------------ REMOVAL ------- 14-0323 STM GYCC DISCONNECT TELEPHONE AND OIS-D COMM 111 I/F CABLES AT OIC MONITOR SHACK SU72140 GYCC JYCJ ON 135 FT LEVEL RSS. CAP FSS END 117 AND STORE CABLES IN MONITOR SHACK. REPORT COMPLETION. 14-0324 NTD OTC AT OIC MONITOR SHACK OF 130/135 FT 232 LEVEL DISCONNECT PLUG FROM FACILITY OTC *PAD POWER AND STOW CABLE INSIDE OIC 132 SHACK. REPORT COMPLETION. 14-0325 -1D04H00M STM QBSE REMOVE STRUCTURE TIE-DOWNS FROM STSA | T-28H00M NET OIC MONITOR SHACK 135 FT LEVEL 104 RSS AND CLEAR NONESSENTIAL PERSONNEL 25 FT AROUND OIC MONITOR SHACK AT 135 FT LEVEL RSS AND 50 FT AT PAD SURFACE. ESSENTIAL PERSONNEL ------------------- CRANE CREW 5 174 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD ORB GH2 T-0 REAC PRESSURIZATION ------------------------------------ 14-0326 CFCP OTC READY TO PROCEED WITH ORB GH2 SU72113 132 T-0 REAC PRESSURIZATION. SU72152 OTC NTD REQUEST ALL PERSONNEL CLEAR FROM 232 FOLLOWING AREAS AND SAFETY CONCURRENCE TO PROCEED. 1. LH2 TSM 2. ORB AFT & MIDBODY 14-0327 NTD *SCC REQUEST SFOC SAFETY CLEAR ALL 232 PERSONNEL FROM FOLLOWING AREAS FOR *SCC *PSE PRSD ORB GH2 T-0 REAC PRESSURIZATION. NET REQUEST SAFETY CONCURRENCE TO PROCEED. 105 1. LH2 TSM 2. ORB AFT & MIDBODY 14-0328 NTD ATTENTION ON PAD___: PA ALL PERSONNEL CLEAR LH2 TSM, ORB AFT AND MIDBODY FOR PRSD ORB GH2 T-0 SYSTEM REACTANT PRESSURIZATION. 14-0329 *PSE *SCC ALL PERSONNEL HAVE BEEN CLEARED NET FROM CONTROL AREA. YOU HAVE SAFETY 105 CONCURRENCE TO PROCEED WITH ORB *SCC NTD GH2 T-0 SYS REAC PRESSURIZATION. 232 NTD OTC WARNING NEXT STEP HAZARDOUS DUE TO GH2 FLOW IN ORB PRSD T-0 SYSTEM. 14-0330 OTC CFCP ALL PERSONNEL HAVE BEEN CLEARED 132 FROM CONTROL AREA. YOU HAVE SAFETY CONCURRENCE TO PROCEED. PERFORM ORB GH2 T-0 SYS REAC PRESSURIZATION PER V1040.002, SEQ____. 175 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GTOE H/S INSTL COMPLETE ----------------------- 14-0331 -1D03H30M CDR OTC ORBITER OPERATION SUPPORT SU72087 T-27H30M 132 SETUP 11 - GTOE HEADSET DELIVERY AND INSTALLATION COMPLETE. NOTE IN NEXT THREE STEPS,DOWNLIST FORMAT WILL BE 60 IF REQUIRED FOR PAYLOAD SUPPORT AND 44 FOR ALL OTHERS (REF OPERATIONS SUPPORT SETUP 24). 14-0332 T-27H30M NTD OTC DPS SWITCHING TO G9 REDUNDANT SU72084 232 TBC SET DOWNLIST ___ (44 OR 60). LPS DURING RS FORMATION DOWNLIST OTC ALL DATA AND LDB POLLING WILL BE 132 INVALID FOR APPROXIMATELY 10 TBC ALL MINUTES. 136 14-0333 NTD OTC FORM G9/RS DL FMT ___ (44 OR 60) 232 PER S0007VL4 (SEQ 49 ITEM 13). OTC CDPS (30 MIN) 132 CDR 176 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DPS IN G9 RS ------------ 14-0334 CDPS OTC TRANSITION TO G9/RS DL FMT ___ SU72084 132 (44 OR 60) COMPLETE. OTC NTD (SEQ 49 S0007VL4). 232 NTD TBC TBC ALL 136 OMRSD V72CA0.050-A NOTE REFERENCE S0007 VL1 ORBITER OPERATION SUPPORT SETUP 24 FOR DETERMINATION OF LAUNCH FORMAT. LAUNCH FORMAT ACTIVATION STEPS (IF NOT 129 OR IF NOT ALREADY ACTIVE) ARE AVAILABLE POST TFL LOAD AT T-39H55M AND AT T-11 HR HOLD. PERFORM NEXT STEP FOR EDO MISSIONS. 14-0335 OTC CDPS VERIFY LAUNCH OI FORMAT ACTIVE. 132 NOT PERFORMED ______ OPERATIONS/FACILITY/WALKDOWN PART B - ------------------------------------- LC-39 PERIPHERY WALKDOWN COMPLETE --------------------------------- 14-0336 *PAD OTC INTEGRATED OPERATION SUPPORT SU72120 132 SETUP 1 (PART B) - OPERATIONS/ SU72132 OTC NTD FACILITY WALKDOWN COMPLETE. 232 STM *SCC 177 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SET CD CLOCK FOR HOLD --------------------- 14-0337 NTD CGLS HOLD CDC AT T-27 HR 00 MIN 00 SEC. 232 14-0338 CGLS HOME CMD KEY - PRESS CDTH -01:0300/00 XMIT CMD KEY - PRESS 14-0339 CGLS NTD CDC WILL HOLD AT T-27 HR 00 MIN 232 00 SEC. CLOSE PAYLOAD BAY DOORS COMPLETE -------------------------------- NOTE DO NOT PERFORM NEXT STEP IF PAYLOAD BAY DOORS CLOSED FOR FLIGHT. 14-0340 -1D03H15M OTC NTD PAYLOAD BAY DOOR CLOSURE T-27H15M 232 COMPLETE. NOT PERFORMED ______ WINDOW COVER REMOVAL, CLEANING ------------------------------ AND INSPECTION COMPLETE ----------------------- 14-0341 *PAD OTC ORBITER PRE-OPERATION SETUP SU72089 132 INSTRUCTION 13 - WINDOW COVER REMOVAL, CLEANING AND INSPECTION COMPLETE. *PAD ______ 178 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PRIOR TO PERFORMANCE OF NEXT STEP, NTD CONTACT PAYLOAD OPS TO ENSURE THAT PCR PHONES ARE NOT IN USE FOR SUPPORT OF CRITICAL PAYLOAD OPERATIONS. SECURE TELEPHONES ----------------- 14-0342 -1D03H15M NTD STM LOCK OUT PAD A/B PCR TELEPHONES COMM T-27H15M 232 PER OMI D3008. REPORT SU72141 STM GYCC COMPLETION. 111 GYCC JYCJ 117 JSOQ PTP QW:_____ 14-0343 CHGD TBC ET PRE-OPERATION SETUP 5 - HWS 136 REMOTE LEAK DETECTOR SYSTEM TBC CMQC PRETEST VERIFICATION COMPLETE. HGDS FINAL SETUPS COMPLETE -------------------------- NOTE DO NOT PERFORM NEXT STEP IF HGDS SETUPS COMPLETED PRIOR TO S0007. 14-0344 CHGD OTC HGDS FINAL SETUPS COMPLETE. SU72574 132 READY TO SUPPORT PRSD LOADING. OTC NTD 232 NOT PERFORMED ______ 179 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 6292 CABINET PURGE INITIATION ----------------------------- 14-0345 OTC *PAD RSS OMBUU ROOF-6292 CABINET 132 *PAD PETG 1. GN2 PURGE VALVE A505975 - OPEN (CCW) CHGD 2. VERIFY AUDIBLE PURGE. T:______ PRSD CRYO PREPS COMPLETE ------------------------ 14-0346 -1D03H00M CFCP OTC ORBITER PRSD CRYO FLOW PREPS ARE T-27H00M 132 COMPLETE. READY TO CLEAR ALL OTC NTD NONESSENTIAL PERSONNEL FROM PAD 232 FOR LO2/LH2 LOADING OPERATIONS. NTD STM RLDS 6292 ACTIVATION -------------------- 14-0347 -1D03H00M CHGD OTC VERIFY OMBUU CAVITY 750 PSI GHE SU72108 T-27H00M 132 PURGE ACTIVE. OTC CFCP 14-0348 CHGD CURSOR CNTL (SAW01/HWW21) MFC POWER - ON PUMP 1 - ON PUMP 3 - ON XMIT CURSOR KEY - PRESS NOTE PERFORM NEXT TWO STEPS IF PRSD PREPS TO BE SPLIT UP DUE TO OTHER SUPPORT REQUIREMENTS THAT WILL INHIBIT COMPLETION OF PREPS PRIOR TO T-27 HRS AND HOLDING. 14-0349 CFCP OTC PRSD SYSTEM IN STABLE SU72163 132 CONFIGURATION AT THIS TIME AND OTC CHGD CFCP WILL MONITOR FCSS FIRE AND LEAK DETECTORS. NOT PERFORMED ______ 180 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0350 CFCP OTC VERIFY CHGD ON STATION TO SUPPORT 132 COMPLETION OF PRSD PREPS. OTC CHGD NOT PERFORMED ______ 14-0351 CFCP OTC FC/PRSD CONSOLE WILL MONITOR 132 FCSS FIRE AND LEAK DETECTORS OTC CHGD UNTIL PRSD TANKER PLACEMENT. 14-0352 STM JBPN ORBITER PRSD CRYO FLOW PREPS PNSA 111 COMPLETE. MONITOR GO2/GH2 SYSTEMS FOR DECAY. LO2 VEHICLE LOAD PRE-OPERATION ------------------------------ SETUPS COMPLETE --------------- 14-0353 -1D03H00M PLOX TBC PRE-OPERATION SETUPS OF LO2 SU72055 T-27H00M 136 SYSTEM PREPS FOR VEHICLE LOAD TBC NTD PER G3151 COMPLETE. 232 PAD AIR COMPRESSOR SERVICING COMPLETE ------------------------------------- 14-0354 -1D03H00M JBPN STM PAD AIR COMPRESSORS HAVE BEEN PNSA T-27H00M 111 SERVICED. SU72139 181 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- HOLD COUNTDOWN CLOCK -------------------- 14-0355 T-27H00M NTD OTC CDC HOLDING AT T-27 HOURS. SU72162 (HOLDING) PA TBC DURATION OF HOLD WILL BE ____ 232 PTC HOURS ____ MINUTES. *MIL STM *SCC LPS NOTE PERFORM NEXT THREE STEPS AFTER CDC IS HOLDING. 14-0356 NTD CGLS SET CDC TO START COUNTING AT _____ 232 HR _____ MIN _____ SEC GMT. 14-0357 CGLS HOME CMD KEY - PRESS CDTC _____/__.000 HHMM SS XMIT CMD KEY - PRESS 14-0358 CGLS NTD CDC WILL START COUNTING AT _____ HR 232 _____ MIN _____ SEC GMT. CREW COMPT INTERIOR (FLT DECK) ------------------------------ INSPECTION AND CLEANING COMPLETE -------------------------------- 14-0359 T-27H00M *PAD OTC INSPECTION OF CREW MODULE SU72117 (HOLDING) 132 INTERIOR FLIGHT DECK PER ORBITER PRE-OPERATION SETUP 11 COMPLETE. 182 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- INTERCENTER VOICE CHECKS ------------------------ NOTE NEXT TWO STEPS REQUIRE ACCESS TO CONTROL ROOM CONSOLES. PERFORM NEXT TWO STEPS AT 0800 E ON DAY SPECIFIED IN SCHEDULING MESSAGE. 14-0360 T-27H00M NTD STM PERFORM INTER-CENTER END-TO-END COMM (HOLDING) 232 VOICE CHECKS PER OMI D3012 FOR SU72201 STM GYCC FOLLOWING LOCATIONS (8 HOURS): 111 *MIL GYCC GYCJ 1. CCAS (TONE AND VOICE) 117 2. MILA 3. JSC 4. MSFC-HOSC 5. DFRC 6. TAL SITES (TONE AND VOICE) 7. SLF OIS-Q 8. GSFC 14-0361 NTD STM PERFORM INTER-CENTER END-TO-END COMM 232 VOICE CHECKS PER OMI D3012 FOR STM GYCC KSC/ROCC POINT-TO-POINTS. (8 HOURS) 111 GYCC JYCJ 117 183 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0362 OTC *PAD PERFORM INSPECTION OF MLP VALVE 132 SKID AND VERIFY THE FOLLOWING: 1. THREADED RODS HOLDING THE DRESSER COUPLER ON THE LOX MAIN FILL VALVE (A86461), MLP SIDE 1, ARE TIGHT ENOUGH NOT TO BE MOVED BY HAND. 2. LOX REPLENISH VALVE (A86460), MLP SIDE 1, HAS PURGE TUBE DIRECTED AT VALVE STEM. 3. TAPE USED DURING SYSTEM LEAK CHECKS REMOVED FROM ALL FLANGES ON SIDES 1, 2 AND 4. MLP SUPERVISOR SIG____________________ 184 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 126.65 MHZ WX CKT COMM CHECKS ----------------------------- 14-0363 STM GYCC CALL SLF CONTROL TOWER (7-2100) COMM 111 AND VERIFY 126.65 MHZ WX CIRCUIT IS CLEAR OF TRAFFIC AND AVAILABLE FOR COMM CHECKS. ADVISE SLF TOWER WHEN COMM CHECKS COMPLETE. 14-0364 T-27H00M GYCC GYCJ PERFORM COMM CHECKS FOR VHF COMM (HOLDING) 117 WEATHER RADIO CIRCUIT TO ICOM-B. AT TECH CONTROL PLACE 3W SW33 IN MSN 1/3. ON LOCAL CONTROL PNL RM131 CONS 1707/1709 ACTIVATE I/C-B. PERFORM VOICE TRANSMISSION ON VHF WX CH 9900 AND VERIFY RX ON OIS CH 215. AFTER COMPLETION, DEACTIVATE PNL AND PLACE 3W SW33 IN POSITION 'I'. REPORT COMPLETION. 14-0365 GYCC GYCJ COMM CHECK VHF WEATHER (2RAC534) COMM 117 JYCJ AND WX BACK-UP (2RAC1534) CIRCUITS TO FOLLOWING LOCATIONS: 1. GYCJ TO JSC. 2. GYCJ TO SLF CONTROL TOWER. 3. GYCJ TO LCC 1/3 CONSOLES AB8, AA5 AND AA6 185 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MOVE TAIR TRAILER TO PAD GATE ----------------------------- 14-0366 OTC NTD PERFORM SUPPORT OPERATION SU72137 232 SUPPORT SETUP 1 TO MOVE TAIR HESA NTD STM TRAILER NO._____ FROM ___ TO _____. (1 HOUR) 14-0367 STM NTD OPERATION SUPPORT SETUP 1 TAIR 232 TRAILER NO.______ MOVE FROM______ NTD OTC TO______ COMPLETE. CONFIG CREW COMPARTMENT ----------------------- AND WHITE ROOM -------------- 14-0368 T-27H00M NTD VERIFY DIGITAL O2 METER IN WHITE SU72175 (HOLDING) ROOM CONFIGURED FOR VIEWING ON OTV. NOTE DO NOT PERFORM NEXT TWO STEPS IF FIXED O2 SYSTEM IN CREW COMPARTMENT IS VERIFIED INSTALLED AND OPERATIONAL. 14-0369 NTD *SCC INSTALL PORTABLE O2 METER IN 232 WHITE ROOM AND VERIFY O2 METER *SCC *PSE READABLE BY OTC. NET 105 NOT PERFORMED ______ 14-0370 *PSE *SCC PORTABLE O2 METER HAS BEEN INSTALLED NET IN WHITE ROOM AND VERIFIED READABLE 105 BY OTC. *SCC NTD 232 NOT PERFORMED ______ 14-0371 OTC JYVR START VIDEO RECORDING OF OTV COMM 138 CAMERA 005/105. (SEE OTC FIG 4) SU72199 186 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0372 OTC OMTO WHITE ROOM CEILING: 132 1. VERIFY CHAMBER DAMPER A122818 IN MARKED POSITION. 2. VERIFY ORBITER ECS DAMPER A122817 IS OPEN AND AIR IS FLOWING THRU ECS DUCT INTO CREW COMPARTMENT. T:______ 14-0373 CECL OTC PARTIAL PRESSURE OF OXYGEN IN 132 CREW COMPARTMENT SATISFACTORY. FIRE COMBAT/EMS PIC TEST PREPS ------------------------------ NOTE PERFORM NEXT STEP IF PIC RESISTANCE TEST WILL BE PERFORMED OR FIRE COMBAT/ EMS NOT ALREADY SUPPORTING. 14-0374 NTD STM FIRE COMBAT REQUIRED AT FIRE FIRE 232 STATION NO. 6 IN 30 MINUTES SU72202 STM JSTC TO SUPPORT PIC TEST. EMS WILL 111 MAINTAIN IN STATION SUPPORT AT JSTC JFIR FIRE STATION NO. 2. 114 NOT PERFORMED ______ ECS CONTROL STA TRANSFER ------------------------ 14-0375 OTC CPVD PERFORM "CONTROL STATION | 132 TRANSFER PAD TO FIRING ROOM" SU72179 | PER OMI V1122. | ECS CONTROL STATION TRANSFER COMPLETE ------------------------------------- 14-0376 T-27H00M CPVD OTC ECS CONTROL STATION TRANSFER - SU72179 (HOLDING) 132 PAD TO FIRING ROOM COMPLETE. 187 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONFIGURE PNL MA73C FOR VENT DR OPS ----------------------------------- 14-0377 CPVD PFP PNL (VAM09A) STATUS VENT DOOR COMMAND FD'S PFPK-4 - PRESS ONCE VERIFY ALL COMMANDS OFF 14-0378 OTC CDR PANEL O6 STAR TRACKER DOOR CONTROL SYS 1 SW - OFF (VERIFY) SYS 2 SW - OFF (VERIFY) POWER -Y SW - OFF (VERIFY) -Z SW - OFF (VERIFY) 14-0379 OTC CDR PANEL C3 AIR DATA PROBE STOW LEFT SW - INHIBIT (VERIFY) RIGHT SW - INHIBIT (VERIFY) AIR DATA PROBE LEFT SW - STOW (VERIFY) RIGHT SW - STOW (VERIFY) 14-0380 OTC CDR PANEL R13L PL BAY MECH PWR SYS 1 SW - OFF (VERIFY) SYS 2 SW - OFF (VERIFY) PL BAY DOOR SW - STOP (VERIFY) PL BAY DOOR ENABLE/DISABLE SYS 1 SW - DISABLE (VERIFY) SYS 2 SW - DISABLE (VERIFY) 14-0381 OTC CDR PANEL R2 ET UMB DOOR MODE SW - GPC (VERIFY) 188 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0382 OTC CDR PANEL MA73C ROW A MCA LOGIC MN A FWD 1 SW - ON (VERIFY) MID 1 SW - ON (VERIFY) MN B FWD 2 SW - ON (VERIFY) MID 1 SW - ON (VERIFY) MID 2 SW - ON (VERIFY) MN C FWD 3 SW - ON (VERIFY) MID 2 SW - ON (VERIFY) ROW B MCA LOGIC MN A AFT 1 SW - ON (VERIFY) MID 3 SW - ON (VERIFY) MN B AFT 2 SW - ON (VERIFY) MID 3 SW - ON (VERIFY) MID 4 SW - ON (VERIFY) MN C AFT 3 SW - ON (VERIFY) MID 4 SW - ON (VERIFY) ROW C MCA POWER AC1 3 PH FWD 1 CB - CLOSE MID 1 CB - CLOSE MCA POWER AC2 3 PH FWD 2 CB - CLOSE MID 1 CB - CLOSE MID 2 CB - CLOSE MCA POWER AC3 3 PH FWD 3 CB - CLOSE MID 2 CB - CLOSE 189 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0382 ROW D CON'T MCA POWER AC1 3 PH AFT 1 CB - CLOSE MID 3 CB - CLOSE MCA POWER AC2 3 PH AFT 2 CB - CLOSE MID 3 CB - CLOSE MID 4 CB - CLOSE MCA POWER AC3 3 PH AFT 3 CB - CLOSE MID 4 CB - CLOSE 14-0383 OTC CPVD PNL MA73C CONFIGURED FOR PRSD SU72169 132 LOAD VENT DOOR OPERATIONS. NOTE DO NOT PERFORM VENT DOOR RECONFIGURATION (CONTINGENCY) IF VENT DOORS IN NORMAL PURGE CONFIGURATION. VENT DOOR RECONFIGURATION (CONTINGENCY) --------------------------------------- NOT PERFORMED ______ 14-0384 CPVD OTC ORBITER VENT DOORS WILL BE SU72177 132 POSITIONED TO NORMAL PURGE OTC *PAD POSITION. 14-0385 T-27H00M CPVD OTC READY TO POSITION ALL VENT DOORS (HOLDING) 132 TO NORMAL PURGE POSITION. OTC NTD 232 14-0386 NTD OTC PROCEED WITH VENT DOOR 232 RECONFIGURATION TO NORMAL PURGE OTC CPVD POSITION. 132 14-0387 CPVD CURSOR CNTL (VAM09A) COMMAND VENT DOOR/S TO REQUIRED POSITION. VERIFY ALL VENT DOORS IN NORMAL PURGE POSITION. 190 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0388 CPVD OTC ORBITER VENT DOORS POSITIONED SU72177 132 TO NORMAL PURGE POSITION. OTC NTD 232 VENT DOOR RECONFIGURATION (CONTINGENCY) --------------------------------------- COMPLETE -------- SRB APU BITE TEST AND APU FUEL ------------------------------ PUMP BEARING SEAL SOAK ---------------------- 14-0389 NTD OTC VERIFY VEHICLE IS IN REDUNDANT 232 SET. OTC CDPS 132 14-0390 T-27H00M NTD TBC VEHICLE IN REDUNDANT SET (DPS). SU72180 (HOLDING) 232 PROCEED WITH SRB POWER UP PER TBC CPWR OMI S9001VL1. (OPT A) 136 RT OMI LOG NO.__________ 14-0391 CPWR TBC SRB POWER ACTIVATION COMPLETE. SU72180 136 TBC NTD 232 NTD OTC 14-0392 OTC CEPD PERFORM MEC PREFLT BITE EVALUATION. 132 14-0393 CEPD PERFORM CDS QLDB RETRIEVAL ON FD VERIFY NO MEC FAILURES 191 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB HPU BITE TEST ----------------- 14-0394 CBHY TBC REQUEST SFOC SAFETY ESTABLISH SU72214 136 25 FT RADIUS CLEAR AROUND LEFT TBC NTD AND RIGHT SRB HPU EXHAUST DUCTS 232 FOR SRB HPU BITE TEST. REQUEST NTD *SCC CONCURRENCE TO PROCEED. *SCC *PSE NET 105 14-0395 NTD ATTENTION ON PAD _____: PA SRB HPU BITE TEST WILL BE PERFORMED. ALL PERSONNEL CLEAR 25 FT RADIUS OF LEFT AND RIGHT HPU EXHAUST DUCTS. 14-0396 *PSE *SCC CONTROL AREA CLEARED AND YOU SU72214 NET HAVE SAFETY CONCURRENCE TO 105 PROCEED. *SCC NTD 232 WARNING HAZARDOUS STEPS FOLLOW DUE TO SRB HPU BITE TEST. 14-0397 NTD TBC PERFORM SRB HPU BITE TEST AND SU72182 232 HPU PUMP BEARING SEAL SOAK PER TBC CBHY SRB OPERATION SUPPORT SETUP 3. 136 192 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- C/W STATUS AND CLEAR MEMORY --------------------------- 14-0398 T-27H00M OTC CISL PERFORM C/W STATUS AND MEMORY SU72173 (HOLDING) 132 CDR CLEAR ON OIS CH 145. (20 MIN) 14-0399 CISL MS1 PANEL R13U CAUTION/WARNING PARAM STATUS SW - INHIBITED (HOLD) REPORT MATRIX LIGHTS ON: RECORD IN S0007 VL4 APPENDIX P-3 14-0400 CISL MS1 PANEL R13U CAUTION/WARNING PARAM STATUS SW - RELEASE 14-0401 CISL MS1 PANEL R13U CAUTION/WARNING MEMORY SW - READ (HOLD) REPORT MATRIX LIGHTS ON: RECORD IN S0007 VL4 APPENDIX P-5 14-0402 CISL MS1 PANEL R13U CAUTION/WARNING MEMORY SW - CLEAR AND RELEASE MEMORY SW - READ (HOLD) REPORT MATRIX LIGHTS ON: RECORD IN S0007 VL4 APPENDIX P-4 14-0403 CISL MS1 PANEL R13U CAUTION/WARNING MEMORY SW - RELEASE 14-0404 CISL CDR PANEL F7 REPORT C/W ANNUNCIATORS ON LITES: RECORD IN S0007 VL4 APPENDIX P-1 14-0405 CISL CDR PANEL C3 CAUTION/WARNING MODE SW - ACK 14-0406 CISL OTC C/W STATUS AND MEMORY CLEAR SU72173 132 COMPLETE. 193 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT STEP IF ORBITER POWERED UP AND CONFIGURED FOR REMOTE OPERATIONS. 14-0407 OTC CISL IF NOT CONFIGURED, CONFIGURE SU72172 CDR ACTIVE OI PCM TO GSE CONTROL (SEQ 38). REPORT COMPLETION. NOT PERFORMED ______ 14-0408 OTC CDR EGRESS CREW MODULE/WHITE ROOM SU72181 *FCM AND PROCEED TO ROADBLOCK A-5 (PAD A) OR A/B-4 (PAD B). 14-0409 CBHY TBC SRB HPU BITE TEST COMPLETE. 136 OMRSD B42AP0.050-B-1R OMRSD B42AP0.060-B-1 14-0410 CBHY TBC SRB HPU FUEL PUMP BEARING SOAK 136 COMPLETE. OMRSD B42AP0.080-A-1R NOTE HAZARDOUS STEPS DUE TO SRB BEARING SOAK COMPLETE. 14-0411 TBC NTD SRB HPU BITE TEST AND HPU FUEL SU72182 232 PUMP BEARING SEAL SOAK PER SRB NTD *SCC OPERATION SUPPORT SETUP 3 COMPLETE. *SCC *PSE REQUEST SFOC SAFETY TO REDUCE CONTROL NET AREA TO INTERIOR PERIMETER OF SOUND 105 SUPPRESSION SYSTEM WATER PIPES. 14-0412 *PSE *SCC CONTROL AREA REDUCED TO INTERIOR NET PERIMETER OF SOUND SUPPRESSION 105 SYSTEM WATER PIPES. *SCC NTD 232 NTD TBC SRB HPU BITE TEST AND HPU FUEL ------------------------------ PUMP BEARING SEAL SOAK COMPLETE ------------------------------- 194 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CCF LPGN2 PREPS --------------- NOTE DO NOT PERFORM NEXT TWO STEPS IF PREVIOUSLY PERFORMED. 14-0413 STM JSTC START CCF INDUSTRIAL LPGN2 PREPS PNU 111 PER M3703 FOR AIR TO GN2 SU72204 JSTC GSPN CHANGEOVER. (2 HRS) 114 NOT PERFORMED ______ 14-0414 STM JSTC START HP GHE/GN2 AND LPGN2 PNU 111 VALVE POSITIONING PER M3704 SU72203 JSTC GSPN FOR AIR TO GN2 CHANGEOVER. 114 (2 HRS) NOT PERFORMED ______ SRB AFT SKIRT GN2 PURGE THERMAL ------------------------------- CONDITIONING ------------ 14-0415 CBHY CRT (BAT04) RECORD PRESENT TIME AND DATE TIME__________GMT DATE__________(MMDDYY) REQUEST ESA TO EXECUTE DATA FILE SRBFB (GRAPHIC PLOTS) WITH A START TIME OF T-27 HRS (REF ONLY PHONE 1-2305) FROM GRAPHIC PLOTS DETERMINE LEFT SRB AND RIGHT SRB LOWEST AVERAGE FLEX BEARING TEMPERATURE AND RECORD: LEFT AVG TEMP______ DEG F BD RIGHT AVG TEMP______ DEG F BD 195 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0415 CBHY CRT (BAT04) CON'T SRB AFT SKIRT GN2 PURGE CURSOR CNTL T (BLOCK) XMIT CURSOR KEY - PRESS CRT NOTE DISPLAY OF FLEX BEARING TEMPERATURES AND NOZZLE TO CASE JOINT TEMPERATURES. RECORD FLEX BEARING TEMPERATURES ______B_______ DEG F BD ______B_______ DEG F BD ______B_______ DEG F BD ______B_______ DEG F BD RECORD NOZZLE CASE JOINT TEMPERATURES ______N_______ DEG F BD ______N_______ DEG F BD ______N_______ DEG F BD CURSOR CNTL T (BLOCK) XMIT CURSOR KEY - PRESS NOTE DISPLAY OF PURGE SCHEMATIC 196 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF EITHER (LEFT OR RIGHT) OF ABOVE RECORDED FLEX BEARING TEMPERATURES WERE LESS THAN 72 DEG F, OR IF ANY ONE OR MORE OF THE EIGHT FLEX BEARING TEMPERATURES WAS LESS THAN 72 DEG F, OR IF ANY ONE OR MORE OF THE SIX NOZZLE TO CASE JOINT TEMPERATURES WAS LESS THAN 75 DEG F. 14-0416 TBC CBHY ACTIVATE SRB GN2 AFT SKIRT PURGE SU72198 136 PER SRB OPERATION SUPPORT SETUP SU72213 5 - SRB AFT SKIRT GN2 PURGE ACTIVATION. NOT PERFORMED ______ 14-0417 NTD CMQC VERIFY APPENDIX K ITEMS CONSTRAINING 232 PRSD LOAD COMPLETE. 14-0418 CMQC NTD APPENDIX K ITEMS CONSTRAINING PRSD 232 LOAD COMPLETE. 197 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE THE SHUTTLE PIC RESISTANCE TEST AND SRB IGN S&A DEVICE VERIFICATION IS TO BE PERFORMED ONLY AFTER FINAL ORBITER AFT, ET IT AND SRB FWD SKIRT CLOSE-OUTS ARE COMPLETE. SHUTTLE PIC RESISTANCE TEST AND ------------------------------- SRB IGN S&A DEVICE VERIFICATION ------------------------------- 14-0419 NTD OTC VERIFY READY TO CLEAR ALL SEC 232 TBC PERSONNEL FROM BLAST DANGER SU72183 PTC AREA. SU72215 STM *SCC *SCC *SEC NET *PSE 105 14-0420 NTD *SCC MOVE ROAD BLOCKS FROM GATE SEC 232 *SEC TO PAD ___ BLAST DANGER AREA. 14-0421 NTD *SCC START CLEARING ALL PERSONNEL SEC 232 *SEC FROM PAD _____ AND BLAST *SCC *PSE DANGER AREA. NET 105 14-0422 NTD ATTENTION ON PAD ___: PA ALL PERSONNEL CLEAR PAD _____ BLAST DANGER AREA FOR SRB SSV PIC RESISTANCE CHECKS AND SRB IGN S&A ROTATION VERIFICATION. 14-0423 NTD *SCC ALL PERSONNEL, INCLUDING SECURITY 232 MONITOR AND SECURITY GUARD, PROCEED *SCC *PSE TO ROADBLOCK A-5 (PAD A) OR A/B-4 NET (PAD B). 105 198 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0424 *SEC *SCC ALL PERSONNEL CLEARED FROM BDA. SEC NET *PSE 105 14-0425 NTD *SCC VERIFY ALL PERSONNEL CLEAR OF BDA. 232 REQUEST SAFETY CONCURRENCE TO *SCC *PSE PERFORM PIC RESISTANCE TEST AND SRB NET IGN S&A ROTATION VERIFICATION. 105 14-0426 NTD STM VERIFY FIRE COMBAT ON STANDBY AT FIRE 232 FIRE STATION NO. 6 AND EMERGENCY SU72200 STM JSTC MEDICAL ON STANDBY AT FIRE STATION 111 NO. 2 FOR PIC RESISTANCE TEST. JSTC JFIR 114 14-0427 *PSE *SCC ALL PERSONNEL CLEAR OF BDA. YOU SU72183 NET HAVE SAFETY CONCURRENCE TO SU72215 105 PERFORM PIC RESISTANCE TEST AND *SCC NTD IGN S&A ROTATION VERIFICATION. 232 NTD OTC TBC 199 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DOWNLIST FORMAT 42 IS REQUIRED FOR SRB IGN S&A DEVICE VERIFICATION. IF NOT IN FORMAT 42, PERFORM NEXT FOUR STEPS. IF DOWNLIST FORMAT 42 IS NOT AVAILABLE, DO NOT PERFORM SRB IGN S&A DEVICE VERIFICATION. 14-0428 OTC NTD VERIFY READY FOR SWITCH TO SU72164 232 DOWNLIST FORMAT 42. OTC ALL 132 NTD TBC 232 PTC TBC ALL 136 PTC ALL 134 NOT PERFORMED ______ 14-0429 NTD OTC SWITCH TO DOWNLIST FORMAT 42. 232 OTC CDPS 132 NOT PERFORMED ______ 14-0430 CDPS CURSOR CNTL (SAS01 PGB) FMT 42 (VAS90) XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT (VAS59 PGB) VERIFY FMT 42 ACTIVE NOT PERFORMED ______ 200 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0431 CDPS OTC TRANSITION TO DOWNLIST 132 FORMAT 42 COMPLETE. OTC NTD 232 OTC ALL 132 NTD TBC 232 TBC ALL 136 NOT PERFORMED ______ WARNING HAZARDOUS STEPS FOLLOW DUE TO PIC RESISTANCE TEST AND SRB S&A ROTATION. ORBITER/GSE PIC RESISTANCE TEST -------------------------------- 14-0432 NTD OTC PROCEED WITH ORBITER/GSE PIC SU72184 232 RESISTANCE TEST. 14-0433 OTC CEPD POWER UP GSE PIC RACKS AND PERFORM 132 ORBITER/GSE PIC RESISTANCE TEST PER SEQ 52 ON CH 151. PIC RACK SECURING ----------------- 14-0434 OTC CEPD CURSOR CNTL (VWC10) SU72185 132 GND SYS - OFF XMIT CURSOR KEY - PRESS CRT (VWC10) VERIFY GND AND CPA VOLTAGES LL 14-0435 CEPD OTC ORBITER/GSE PIC RESISTANCE TEST 132 COMPLETE AND GROUND PIC RACKS OTC NTD SECURED. 232 201 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB PIC TEST ------------ 14-0436 NTD TBC PROCEED WITH SRB PIC RESISTANCE SU72186 232 TEST PER S0007VL4 (SEQ 48) ON TBC CPWR CH 176. (10 MIN) 136 14-0437 CPWR TBC SRB PIC RESISTANCE TEST COMPLETE. 136 TBC NTD 232 NTD OTC WARNING BDA MUST BE CLEARED AND CONTROLLED SWITCHING AND CONTROLLED LPS COMMANDS ARE IN EFFECT THROUGHOUT S&A DEVICE ROTATION. DO NOT PERFORM S&A DEVICE ROTATION DURING A PHASE I OR PHASE II LIGHTNING ADVISORY. HAZARDOUS OPERATIONS FOLLOW. BDA CLEAR REMAINS IN EFFECT. DO NOT ROTATE SRB IGN S&A DEVICE WITH IGNITER HEATER POWER ON. NOTE DOWNLIST FORMAT 42 IS REQUIRED FOR SRB IGN S&A DEVICE VERIFICATION. DO NOT PERFORM NEXT THREE STEPS IF FMT 42 UNAVAILABLE. 14-0438 NTD ALL SRB IGN S&A DEVICE VERIFICATION SU72187 PA TEST WILL START MOMENTARILY. CONTROLLED SWITCHING AND CONTROLLED LPS COMMANDING ARE IN EFFECT. NOT PERFORMED ______ 202 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0439 NTD TBC PROCEED WITH IGNITION S&A 232 DEVICE VERIFICATION PER S0007VL4 TBC CPWR SEQ 61 ON CHANNEL 176. 136 NOT PERFORMED ______ 14-0440 CPWR TBC S&A DEVICE VERIFICATION COMPLETE. 136 TBC NTD 232 NOT PERFORMED ______ 14-0441 NTD *SCC PIC RESISTANCE TEST COMPLETE. SEC 232 STM MOVE ROADBLOCK FROM PAD ___ SU72190 *SCC *PSE BLAST DANGER AREA TO PAD ___ NET GATE. 105 STM JSTC 111 JSTC *SEC 114 NOTE HAZARDOUS STEPS COMPLETE. PIC RESISTANCE TEST COMPLETE. S&A'S IN SAFE POSITION. PAD PERIMETER CLEAR WILL BE MAINTAINED EXCEPT FOR ESSENTIAL PERSONNEL HAZ BADGED FOR PRSD OPERATIONS. 203 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0442 *SEC JSTC BLAST DANGER AREA OPENED. PAD SEC 114 PERIMETER CLEAR IN EFFECT SU72216 JSTC STM 111 STM NTD 232 NTD OTC TBC *SCC *SCC *PSE NET 105 SHUTTLE PIC RESISTANCE TEST AND SRB ----------------------------------- IGN S&A DEVICE VERIFICATION COMPLETE ------------------------------------ 14-0443 STM *OPS VERIFY NUMBER OF SRM SEGMENT 111 RAILCARS THAT ARE LOCATED AT THE BEACH SIDING. (PHONE 1-5108) NUMBER OF RAILCARS__________ NOTE PERFORM THE FOLLOWING TWO STEPS ON L-2 DAY IF SRM SEGMENT RAILCARS ARE LOCATED AT BEACH SIDING. 14-0444 STM JSTC MOVE _____ SRM SEGMENT RAILCARS SU72254 11 FROM BEACH SIDING TO BALLOON SIDING. NOT PERFORMED ______ 14-0445 STM NTD _____SRM SEGMENT RAILCARS ARE BEING 232 MOVED FROM BEACH SIDING TO BALLOON SIDING. NOT PERFORMED ______ 204 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0446 NTD FOLLOWING PERSONNEL REQUIRED TO SU72111 SUPPORT AIR TO GN2 CHANGEOVER AND CRYO LOAD. ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- (TANKER PLACEMENT/CRYO LOAD) ---------------------------- NOTE MANLOADED CHANGEOUT CREWS WILL BE STAGED IN SCAPE TRAILERS. SFOC NASA JBOSC ---- ---- ----- ENGR 2 1 2 TECH 6 4 QC 4 2 SAF 1 1 ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- (AIR TO GN2 CHANGEOVER) ----------------------- SFOC NASA ---- ---- ENGR 1 1 ECS TECH 4 QC SAFETY 1 1 ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- (PTCR/ECS ROOM PRESS.) ---------------------- GSS NASA SFOC --- ---- ---- SAFETY 1 1 SUPR/ENG 2 TECH 2 QUAL 1 205 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0446 ESSENTIAL PERSONNEL (HAZ BADGE) CON'T ------------------------------- (CREW MODULE & WHITE ROOM) -------------------------- SFOC ---- SCO 2 OIC 1 NOTE BLUE COLLAR COVERALLS WILL BE REQUIRED FOR INGRESS IF PRSD TANKER PLACEMENT AND CONNECT IS PERFORMED IN PARALLEL WITH MEC POWER DOWN. 14-0447 OTC *PAD READY TO INGRESS CREW MODULE SU72192 132 FOR POST PIC TEST SAFING. REQUEST CDR AND OIC REPORT TO WHITE ROOM. 14-0448 OTC NTD REQUEST SAFETY VERIFY O2 LEVELS SU72191 232 ACCEPTABLE FOR ORBITER ACCESS. NTD *SCC *SCC *PSE NET 105 14-0449 *PSE *SCC CREW MODULE O2 LEVELS ACCEPTABLE. NET YOU HAVE SAFETY CONCURRENCE TO 105 ACCESS CREW MODULE. *SCC NTD 232 NTD OTC 14-0450 OTC CDR INGRESS CREW MODULE. 132 14-0451 NTD STM FIRE RESCUE AND EMERGENCY SU72200 232 MDICAL SERVICE IN STATION SUPPORT STM JSTC RELEASED FROM PIC RESISTANCE TEST. 111 JSTC JFIR 206 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DPS TO DOWNLIST FORMAT 44/60 ---------------------------- (POST PIC TEST) --------------- NOTE PERFORM NEXT FOUR STEPS IF CURRENTLY IN DL FMT 42. IN NEXT FOUR STEPS DL FORMAT WILL BE 60 IF REQUIRED FOR PAYLOAD SUPPORT AND 44 FOR ALL OTHERS (REF OPERATIONS SUPPORT SETUP 24). 14-0452 OTC NTD VERIFY READY TO SUPPORT SU72165 232 FORMAT _____ (44 OR 60). OTC ALL 132 NTD TBC 232 PTC TBC ALL 136 NOT PERFORMED ______ 14-0453 NTD OTC TRANSITION BACK TO DOWNLIST 232 FORMAT _____ (44 OR 60). OTC CDPS 132 NOT PERFORMED ______ 14-0454 CDPS CURSOR CNTL (SAS01 PG B) FMT ___ (44 OR 60) XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT (VAS59 PG B) VERIFY SELECTED DL FMT ACTIVE NOT PERFORMED ______ 207 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0455 CDPS OTC TRANSITION TO DOWNLIST SU72165 132 FORMAT _____ COMPLETE OTC NTD (44 OR 60). 232 NTD TBC PTC NOT PERFORMED ______ 14-0456 TBC CPWR PERFORM SRB POWER DOWN PER SU72188 136 CBDP OMI S9001VL1. RT OMI LOG NO.__________ 14-0457 CPWR TBC SRB POWER DOWN COMPLETE. 136 TBC NTD 232 14-0458 OTC CEPD PERFORM MEC PREFLT BITE SU72189 132 EVALUATION FOR MEC PIC RESISTANCE TEST AND SRB POWER DOWN. 14-0459 CEPD PERFORM CDS QLDB RETRIEVAL ON FD VERIFY NO MEC FAILURES 14-0460 NTD OTC PERFORM MEC POWER DOWN PER SU72193 232 OMI S9001VL1. OTC CEPD 132 RT OMI LOG NO._________ 14-0461 CEPD OTC MEC PRE FLIGHT BITE SUCCESSFUL 132 EVALUATION COMPLETE. OTC NTD 232 14-0462 CEPD OTC MEC POWER DOWN COMPLETE. 132 OTC NTD 232 208 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- HP GHE/GN2/LPGN2 VLV POSITIONING -------------------------------- COMPLETE -------- NOTE DO NOT PERFORM NEXT TWO STEPS IF PREVIOUSLY PERFORMED. 14-0463 GSPN JSTC HP GHE/GN2 AND LPGN2 VLV PNU 114 POSITIONING COMPLETE. SU72203 JSTC STM 111 NOT PERFORMED ______ 14-0464 GSPN JSTC CCF INDUSTRIAL LPGN2 PREPS PNU 114 COMPLETE. SU72204 JSTC STM 111 QV:_____ QA NOT PERFORMED ______ CCF-39 CONFIGURED FOR LPGN2 FLOW -------------------------------- 14-0465 T-27HOOM GSPN JSTC CCF-39 GN2 PRODUCTION PLANT PNU (HOLDING) 114 READY TO SUPPORT PRSD LOAD. SU72176 JSTC STM SU72210 111 STM NTD 232 209 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0466 NTD STM FIRE COMBAT REQUIRED AT FIRE FIRE 232 STATION NO. 6 IN 30 MINUTES TO SU72205 STM JSTC SUPPORT PRSD LOAD. EMERGENCY 111 MEDICAL WILL MAINTAIN ON STANDBY JSTC JFIR SUPPORT AT FIRE STATION NO. 2. 114 14-0467 T-27H00M NTD OTC CDC WILL START COUNTING AT T-27 (HOLDING) PA TBC HR IN FIVE MINUTES. 232 *MIL STM PTC *SCC LPS 14-0468 T-27H00M NTD ALL CDC AT T-27 HR AND COUNTING. (COUNTING) 232 PA LRD L-2 DAY VERIFICATIONS ------------------------- NOTE SOME LANDING SITES MAY NOT BE MANNED DUE TO MISSION REQUIREMENTS. 14-0469 T-27H00M LRD VERIFY NO OPEN ITEMS/CONSTRAINTS (COUNTING) LF1 IDENTIFIED FOR LAUNCH. NOT SITE GO NO/GO MANNED ---- -- ----- ------ BANJUL ______ ______ ______ BEN GUERIR ______ ______ ______ ZARAGOZA ______ ______ ______ MORON ______ ______ ______ DFRF ______ ______ ______ WSSH ______ ______ ______ 210 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF DUAL MODE COOLING WILL BE REQUIRED THIS LAUNCH. 14-0470 OTC CECL CONFIGURE FREON LOOPS TO RAD SU72167 132 FLOW PER ORBITER OPERATION SUPPORT SETUP 8. REPORT COMPLETION. NOT PERFORMED ______ CLEAR PAD FOR PRSD LOADING AND ------------------------------ AIR TO GN2 CHANGEOVER ---------------------- NOTE DO NOT PERFORM NEXT STEP IF PERSONNEL HAVE ALREADY CLEARED CM AND WHITE ROOM. 14-0471 OTC CDR EGRESS CM AND WHITE ROOM. HAVE 132 *FCM PERSONNEL REPORT TO FALL BACK AREA. NOT PERFORMED ______ WARNING HAZARDOUS OPERATIONS - PRSD LO2/LH2 LOADING AND AIR TO GN2 CHANGEOVER - FOLLOW. NOTE PERFORM NEXT STEP IF SHUTTLE PIC RESISTANCE TEST WAS PERFORMED. 14-0472 OTC NTD VERIFY PAD ___ REMAINS CLEARED 232 TO PERIMETER FENCE FOR PRSD NTD *SCC TANKER PLACEMENT, ECS AIR TO GN2 CHANGEOVER AND ORBITER PRSD LOADING. NOT PERFORMED ______ 211 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT THREE STEPS IF SHUTTLE PIC RESISTANCE TEST WAS PERFORMED. 14-0473 -1D03H00M NTD OTC VERIFY READY TO CLEAR ALL T-27H00M 232 TBC NONESSENTIAL PERSONNEL TO STM PERIMETER FENCE FOR PRSD TANKER *SCC PLACEMENT, ECS AIR TO GN2 CHANGEOVER PTC AND ORBITER PRSD LOADING. NOT PERFORMED ______ 14-0474 NTD *SCC TURN ON PAD ___, A-5, B-4 AND A/B-11 232 ROADBLOCK AREA WARNING LIGHTS TO *SCC *PSE FLASHING AMBER. NET 105 NOT PERFORMED ______ 14-0475 *PSE *SCC PAD___, A-5, B-4 AND A/B-11 ROADBLOCK NET AREA WARNING LIGHTS ARE FLASHING 105 AMBER. *SCC NTD 232 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF SHUTTLE PIC RESISTANCE TEST WAS PERFORMED. 14-0476 NTD *SCC REQUEST SFOC SAFETY ALLOW 232 ESSENTIAL PERSONNEL ACCESS *SCC *PSE TO PAD FOR AIR TO GN2 NET CHANGEOVER AND PRSD CRYO 105 LOAD. POST SAFETY WARNING SIGN AT ECS DOOR THREE. NOT PERFORMED ______ 212 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT TWO STEPS IF SHUTTLE PIC RESISTANCE TEST WAS PERFORMED. 14-0477 -1D03H00M NTD *SCC REQUEST SFOC SAFETY CLEAR T-27H00M 232 NONESSENTIAL PERSONNEL FROM PAD *SCC *PSE TO PERIMETER FENCE FOR AIR TO GN2 NET CHANGEOVER AND PRSD CRYO LOAD. 105 POST SAFETY WARNING SIGN AT ECS DOOR THREE. NOT PERFORMED ______ 14-0478 -1D03H00M NTD OTC ATTENTION ON PAD ___: T-27H00M PA TBC 232 STM ALL NONESSENTIAL PERSONNEL CLEAR *SCC THE PAD TO PERIMETER FENCE FOR PTC PRSD TANKER PLACEMENT, ECS AIR TO GN2 CHANGEOVER AND PRSD LO2 AND LH2 LOADING OPERATIONS. NOT PERFORMED ______ PTCR/ECS ROOM PRESSURIZATION PREPS ---------------------------------- 14-0479 NTD STM PERFORM PRESSURIZATION PREPS FOR HVAA 232 PTCR/ECS ROOM AMD PRESSURIZE SU72207 STM JBAC EAST AND WEST FLAME CELLS PER SU72208 111 OMI M3034 CLOSEOUT PERSONNEL MEET SAFETY ON PAD SURFACE TO PERFORM UPPER BLAST DOOR CLOSURE FIRST. SAFETY/CLOSEOUT PERSONNEL SHALL THEN PROCEED TO PTCR/ECS AREA. 14-0480 NTD *SCC REQUEST SAFETY MEET WITH CLOSEOUT 232 PERSONNEL ON PAD SURFACE FOR UPPER *SCC *PSE BLAST DOOR CLOSURE. NET 105 213 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FIRE COMBAT SUPPORT AT FIRE STATION ----------------------------------- NO. 6/EMS SUPPORT AT FIRE STATION 2 ----------------------------------- 14-0481 -1D03H00M NTD STM VERIFY FIRE COMBAT AND EMERGENCY FIRE T-27H00M 232 MEDICAL IN STATION. SU72197 STM JSTC 111 JSTC JFIR 114 14-0482 JSTC STM FIRE COMBAT ON STANDBY AT FIRE JSTC 111 STATION NO. 6. EMERGENCY MEDICAL STM NTD SUPPORT ON STANDBY AT FIRE 232 STATION 2. NTD *SCC *SCC *PSE NET 105 NOTE LEAK DETECTOR 6127A7 AND FIRE DETECTOR 6127A8 ARE NOT REQUIRED UNTIL LH2 TANKER CONNECTION. 14-0483 CHGD OTC CHGD WILL MONITOR LH2 AND FCP 132 CFCP HLDS/HFDS UNTIL COMPLETION OF PRSD LO2/LH2 CRYO LOAD. NOTE PERFORM NEXT STEP NO LATER THAN 1.5 HOURS PRIOR TO PRSD CRYO LO2 LOADING. 14-0484 OTC CHGD PERFORM HGDS, BUHGDS AND HUMS SU72194 132 ACTIVATION. 214 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TANKER STATUS (PRSD LOADING OPS) -------------------------------- 14-0485 STM JSTC VERIFY TANKERS ARE READY TO PN 111 SUPPORT V1040.002 - PRSD CRYO LOAD. JSTC GSPS SAFETY CONCURRENCE FOR TANKER NET PLACEMENT REQUIRED. NTD WILL 104 GIVE GO FOR TANKERS TO PROCEED TO PAD. 14-0486 -1D03H00M NTD *SCC POSITION SAFETY SIGNS FOR AIR/ SU72212 T-27H00M 232 GN2 CHANGEOVER AT AREAS LISTED SU72274 *SCC *PSE BELOW AND REPORT COMPLETE. NET REQUEST SAFETY CONCURRENCE TO 105 PROCEED WITH AIR TO GN2 STANDBY MODE. NOTE PLACE SIGNS CLOSE TO VEHICLE TO ALLOW WORK SPACE ON RSS PLATFORMS IN SUB-STEPS 6 AND 7. PTCR BLAST DOORS MUST BE CLOSED BY GSS PRIOR TO PERFORMANCE OF SUBSTEP 2. 1. PTCR ECS ROOM DOORS(3) 2. PTCR PAD BLAST DOORS. 3. MLP A, B, ZERO, EAST AND WEST ACCESS PLATFORM STAIRS (SIDE 2 AND 4) 4. LOX AND LH2 TSM'S 5. FRCS ROOM - 193 FT LEVEL 6. * ORB DOOR 44 7. * ORB 50-1, 50-2 DOORS ACCESS PLATFORM - CLEAR AFT FUSELAGE 8. PCR ROOM 9. OAA (* = UNLESS CLOSED OUT FOR FLIGHT) 215 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD LO2/LH2 TANKER PLACEMENT ----------------------------- NOTE LH2/LO2 TANKER PLACEMENT MAY BE PERFORMED IN PARALLEL WITH PAD CLEAR/AIR TO GN2 CHANGEOVER AND MEC POWER DOWN OPERATIONS. 14-0487 1D03H00M NTD *SCC VERIFY SAFETY CONCURRENCE FOR SU72217 T-27H00M 232 TANKER PLACEMENT ON PAD SURFACE *SCC *PSE NET 105 14-0488 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO NET POSITION TANKERS ON PAD SURFACE. 105 *SCC NTD 232 14-0489 NTD STM PERFORM LO2/LH2 TANKER PLACEMENT PN 232 PER SUPPORT OPERATION SUPPORT SU72206 STM JSTC SETUP 5 & 6. SU72170 111 JSTC GSPS NET 104 14-0490 NTD *SCC VERIFY 50 FT CLEAR AREA AROUND 232 LO2/LH2 TANKERS PER SUPPORT *SCC *PSE OPERATION SUPPORT SETUPS 5 AND 6. NET 105 14-0491 CFCP OTC REQUEST ESSENTIAL PERSONNEL 132 REPORT ON STATION FOR PRSD TANKER OTC *PAD PLACEMENT/CRYO LOAD. 216 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ECS FINAL PREPS --------------- (HAND VALVES CLOSED) -------------------- 14-0492 OTC CPVD PERFORM "PREPS FOR AIR/GN2 | 132 CHANGEOVER OPTION B - FINAL SU72166 | PREPS" PER OMI V1122 (HAND | VALVES CLOSED). (15 MIN) | RT OMI LOG NO.__________ 14-0493 -1D02H30M CPVD OTC FINAL PREPS FOR AIR/GN2 T-26H30M 132 CHANGEOVER (HAND VALVE CLOSED) OTC NTD COMPLETE. 232 STANDBY GN2 MODE (HANDVALVES OPEN) ---------------------------------- 14-0494 -1D02H30M *PSE *SCC ALL NONESSENTIAL PERSONNEL HAVE SU72168 T-26H30M NET BEEN CLEARED TO PAD PERIMETER FENCE. 105 SAFETY SIGNS ARE POSITIONED. YOU *SCC NTD HAVE SAFETY CONCURRENCE TO PROCEED 232 WITH "STANDBY GN2 MODE (HAND VALVES OPEN)" OPERATION. 14-0495 OTC CPVD BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. 217 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING HAZARDOUS STEPS FOLLOW DUE TO AIR TO GN2 CHANGEOVER - STANDBY MODE. EACH PERSON ON STATION IN ECS ROOM DURING FLOW OF GN2 WILL HAVE AN ELSA (10 MIN) IN THEIR IMMEDIATE AREA. 14-0496 -1D02H30M NTD OTC PROCEED TO ECS GN2 STANDBY MODE T-26H30M 232 BY PERFORMING OMI V1122 AIR-TO-GN2 OTC CPVD STANDBY MODE/AIR-TO-GN2 CHANGEOVER 132 OPTION A - STANDBY MODE. (15 MIN) RT OMI LOG NO.__________ PTCR/ECS ROOM PRESSURIZATION PREPS ---------------------------------- COMPLETE -------- 14-0497 -1D02H30M JBAC STM PTCR/ECS ROOM PRESSURIZATION HVAA T-26H30M 111 PREPS COMPLETE. SU72207 EAST AND WEST FLAME CELL CLOSEOUT ---------------------------------- COMPLETE -------- 14-0498 JBAC STM EAST AND WEST FLAME CELL HVAA 111 PRESSURIZATION COMPLETE. SU72208 218 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2/LO2 TANKER PLACEMENT COMPLETE --------------------------------- 14-0499 GSPS JSTC LH2/LO2 TANKER PLACEMENT PER PN JSTC STM SUPPORT OPERATION SUPPORT SU72170 111 SETUP 5 AND 6 COMPLETE. SU72206 STM NTD 232 NTD OTC OTC CFCP 132 LH2/LO2 TANKER CONNECTION ------------------------- 14-0500 CFCP OTC READY TO PROCEED WITH LH2/LO2 SU72222 132 TANKER CONNECTION. REQUEST SAFETY OTC NTD CONCURRENCE TO PROCEED. 232 NTD *SCC 14-0501 *SCC *PSE VERIFY ALL NONESSENTIAL PERSONNEL NET CLEARED FROM PAD SLOPE AND ABOVE. 105 VERIFY ALL PERSONNEL INVOLVED WITH FLOW OF LO2 AND LH2 WEAR CLEAN FLAME RETARDANT COTTON COVERALLS. UPON INITIATION OF CRYO FLOW, PERSONNEL OPERATING HAND VLVS, MAKING OR BREAKING LINES, WEAR FACESHIELDS, SAFETY APPROVED LEATHER GLOVES, AND NON-POROUS, NON SPARKING LEATHER OR RUBBER FOOTWEAR. VERIFY FLARE STACK WARNING LIGHTS ON. 14-0502 *PSE *SCC ESSENTIAL PERSONNEL PROPERLY NET ATTIRED. PAD SLOPE AND ABOVE 105 CLEAR OF ALL NONESSENTIAL PERSONNEL. *SCC NTD FLARE STACK WARNING LIGHTS ON. 232 YOU HAVE SAFETY CONCURRENCE TO NTD OTC PROCEED WITH TANKER CONNECTION OTC CFCP AND INERT PURGE PER V1040.002 132 SEQ _____. 219 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0503 CFCP JYVO POSITION AND START RECORDING OF COMM 138 JYVR OTV CAMERAS 008/108 AND 036/136. SU72264 PAN CAMERA 008/108 TO L02 LP SKID. PAN CAMERA 036/136 TO TANKER I/F. 14-0504 CFCP JYVO POSITION AND START RECORDING OF COMM 138 JYVR OTV CAMERAS 007/107 AND 035/135. PAN CAMERA 007/107 TO LH2 LP SKID AND 035/135 TO TANKER I/F. STANDBY GN2 MODE - COMPLETE --------------------------- 14-0505 -1D02H15M CPVD OTC STANDBY GN2 MODE (HAND VALVES SU72168 T-26H15M 132 OPEN) OPERATIONS COMPLETE OTC NTD PER V1122. ECS ROOM/PVD 232 PERSONNEL CLEARING CONTROL AREA. NTD *SCC *SCC *PSE NET 105 PTCR/ECS ROOM PRESSURIZATION ---------------------------- 14-0506 -1D02H15M NTD STM PRESSURIZE PTCR/ECS ROOM WITH SU72174 T-26H15M 232 *SCC AIR AND HAVE PTCR/ECS ROOM SU72209 PERSONNEL CLEAR PAD WHEN COMPLETE. NOTE PTCR/ECS ROOM WILL BE PRESSURIZED WITH AIR WHEN ECS GROUND LVL DOOR IS CLOSED. 14-0507 NTD ATTENTION ON PAD _____: PA PTCR/ECS ROOM WILL BE PRESSURIZED WITH AIR MOMENTARILY. 14-0508 STM JBAC PRESSURIZE PTCR AND ECS ROOM HVAA 111 PER OMI M3034. 14-0509 JBAC STM PTCR AND ECS ROOM PRESSURIZED HVAA 111 WITH AIR PER OMI M3034. STM NTD 232 220 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0510 *SCC *PSE VERIFY SAFETY SIGN IS POSTED AT NET GROUND LEVEL PTCR AND ECS 105 PERSONNEL DOORS PRIOR TO DEPARTING AREA. 14-0511 *PSE *SCC SAFETY SIGN POSTED AT GROUND LEVEL NET PTCR AND ECS PERSONNEL DOORS. 105 14-0512 -1D02H00M JSTC GSPN VERIFY PNEUMATICS OPERATIVE PNU T-26H00M 114 PERSONNEL AT GN2 INDUSTRIAL SUPPLY INTERFACE PER M3703. PAD CLEAR COMPLETE ------------------ 14-0513 -1D02H00M *PSE *SCC ALL NONESSENTIAL PERSONNEL SU72178 T-26H00M NET (INCLUDING ECS/PVD PERSONNEL) HAVE 105 BEEN CLEARED TO PAD PERIMETER *SCC NTD FENCE FOR PRSD LOADING AND 232 AIR TO GN2 CHANGEOVER OPERATIONS. YOU HAVE SAFETY CONCURRENCE TO PROCEED WITH ECS AIR TO GN2 CHANGEOVER. AIR TO GN2 CHANGEOVER --------------------- WARNING GN2 WILL FLOW INTO ORBITER FWD PAYLOAD BAY, AND AFT FUSELAGE, BREATHING OF NITROGEN GAS FROM ORBITER COMPARTMENT PURGE CAN BE LETHAL. 14-0514 -1D02H00M NTD STM SUPPORT AIR TO LPGN2 CHANGEOVER PNU T-26H00M 232 PER OPERATION INSTRUCTIONS OF SU72257 STM JSTC M3703. GSPN COORDINATE WITH 111 CPVD ON CH 172. JSTC GSPN 114 221 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0515 -1D02H00M NTD OTC PERFORM ECS AIR TO GN2 CHANGEOVER SU72224 T-26H00M 232 PER OMI V1122 SEQUENCE "AIR TO OTC CPVD GN2 STANDBY MODE/AIR TO GN2 132 CHANGEOVER OPTION B - GN2 CHANGEOVER". COORDINATE WITH GSPN ON OIS CH 172. RT OMI LOG NO.__________ 14-0516 STM JBEP AIR TO GN2 CHANGEOVER IN PWR 111 PROGRESS. POSSIBILITY OF LOW LEVEL O2 ALARMS. ADVISE STM IF ALARMS OCCUR. HGDS CONFIDENCE CHECKS ---------------------- NOTE HGDS CONFIDENCE CHECKS SHOULD START NO LATER THAN COMPLETION OF AIR TO GN2 CHANGEOVER. 14-0517 -1D01H30M OTC CHGD PERFORM HGDS AND BUHGDS REMOTE SU72225 T-25H30M 132 AUTOCALS AND CONFIDENCE CHECKS. (30 MIN) __________ GMT 222 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0518 CHGD HGDS AND BUHGDS CONFIDENCE CHECKS COMPLETE. HGDS ---- TEST GAS CYLINDER NO.:__________BD GAS CERTIFIED VALUE ANALYZED VALUE TOLERANCE --- --------------- -------------- --------- H2 __________ BD __________ BD +/- 60 HE __________ BD __________ BD +/- 60 O2 __________ BD __________ BD +/- 60 AR __________ BD __________ BD +/- 15 BUHGDS ------ TEST GAS CYLINDER NO.:__________BD GAS CERTIFIED VALUE ANALYZED VALUE TOLERANCE --- --------------- -------------- --------- H2 __________ BD __________ BD +/- 100 HE __________ BD __________ BD +/- 1000 O2 __________ BD __________ BD +/- 100 AR __________ BD __________ BD +/- 30 HUMS ---- GN2 TEST GAS CYLINDER NO. __________ BD GAS CERTIFIED VALUE (CV) ANALYZED VALUE TOLERANCE --- -------------------- -------------- --------- H2 __________ BD __________ CV +/- 100 HE __________ BD __________ CV +/- 1000 O2 __________ BD __________ CV +/- 100 AR __________ BD __________ CV +/- 30 223 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0519 -1D01H00M CPVD OTC ECS AIR TO GN2 CHANGEOVER SU72224 T-25H00M 132 CHGD COMPLETE (V1122). ORBITER BEING OTC NTD PURGED WITH GN2 AT __________ 232 (RECORD TIME). NTD *SCC PTC NOTE | | PERFORM THE FOLLOWING STEP | FOR STS-93. | | 14-0520 PTC OTC AFTER CIRCUIT STABILIZES PERFORM | 132 ORBITER OPERATION SUPPORT SETUP 15 - | OTC CPVD PAYLOAD BAY PURGE VERIFICATION. | CMQC | NOTIFY PTC IMMEDIATELY IF PURGE | GOES OUT OF SPEC. (STS-93) | | NOT PERFORMED ______| | NOTE PERFORM NEXT STEP IF O2 LEVEL IN THE WHITE ROOM IS LESS THAN 20 PERCENT AS INDICATED ON W/R O2 METER. 14-0521 CPVD INCREASE CABIN CIRCUIT FLOW RATE TO 75-80 LBS/MIN. TIME______ NOT PERFORMED ______ 224 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OPEN ORBITER VENT DOORS 1 & 2 ----------------------------- (CONTINGENCY) ------------- NOTE PERFORM NEXT TWO STEPS IF O2 CONCENTRATION IN OAA WHITE ROOM BECOMES LESS THAN 20 PCT AS INDICATED ON W/R O2 METER (OTV CAM 005/105), PERFORM NEXT TWO STEPS TO OPEN LEEWARD VENT DOORS 1&2. 14-0522 -1D01H00M CPVD CURSOR CNTL (VAM31A/VAM09A) SU72227 T-25H00M VENT DOORS 1&2 (LEEWARD) - OPEN TARGET CRT (VAM09A) VERIFY LEEWARD VENT DOOR 1 & 2 ARE OPEN. NOT PERFORMED ______ 14-0523 CPVD OTC ORBITER VENT DOORS 1 AND 2 132 OPENING COMPLETE. OTC NTD 232 NTD *SCC NOT PERFORMED ______ 225 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT TWO STEPS IF VERIFIED PRIOR TO CTS. 14-0524 STM GYCC VERIFY SUPPORT PRE-OPERATION COMM 111 SETUP 7 - COMMUNICATION SUPPORT COMPLETE. NOT PERFORMED ______ 14-0525 STM CMQC SUPPORT PRE-OPERATION SETUP 7 - 111 COMMUNICATION SUPPORT COMPLETE. 232 NTD NOT PERFORMED ______ LH2 TANKER VENT LINE O2 CHECK ----------------------------- 14-0526 CFCP OTC PERFORM O2 LVL CK OF TANKER SU72226 132 VENT LINE. VERIFY CONCENTRATION SU72275 OTC NTD LESS THAN 1 PCT. 232 NTD *SCC *SCC *PSE NET 105 14-0527 *PSE *SCC O2 LVL CHECK COMPLETE NET AND VERIFIED LESS THAN 105 1 PCT CONCENTRATION. *SCC NTD 232 NTD OTC OTC CFCP 132 226 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD LH2/LO2 TANKER CONNECTIONS COMPLETE ---------------------------------------- 14-0528 CFCP OTC LH2/LO2 TANKER CONNECTIONS, LEAK JSTC 132 CHECKS AND INERT PURGE COMPLETE. SU72222 OTC NTD READY TO PERFORM LO2 SERVICING. 232 NTD STM STM JSTC 111 ORBITER CRYO LO2 SERVICING -------------------------- AND SAMPLING (V1040.002 SEQ ___) -------------------------------- 14-0529 JBPN STM FACILITY GO2 AND GH2 SYSTEMS AND PNSA 111 CROSS-COUNTRY LINES PRESSURIZED STM NTD AND READY TO SUPPORT PRSD 232 SERVICING. (GO2 IN USE FROM NTD OTC T-25 TO T-22:30) (GH2 IN USE OTC CFCP FROM T-22:30 TO T-20) 132 14-0530 *SCC NTD VERIFY SYSTEMS READY TO SUPPORT 232 PRSD LO2 CRYO LOAD. NTD OTC OTC CHGD 132 14-0531 OTC CHGD PERFORM HGDS MONITORING ON ALL 132 ORBITER AREAS (PAYLOAD BAY, MIDBODY AND AFT). REPORT OUT OF TOLERANCE CONDITIONS TO CFCP ON OIS CH 153: O2 = INCREASE ABOVE BASELINE 14-0532 OTC CHGD VERIFY MIDBODY O2 LESS THAN 10,000 PPM 132 14-0533 -1D01H00M NTD *SCC VERIFY CONCURRENCE TO FLOW T-25H00M 232 LIQUID OXYGEN TO ORBITER PRSD TANKS. 227 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0534 *SCC NTD SAFETY VERIFIES CONCURRENCE TO 232 PROCEED WITH ORBITER PRSD SERVICING AND SAMPLING. (V1040.002) 14-0535 NTD OTC PROCEED WITH ORBITER LO2 SU72228 232 TANK SERVICING AND SAMPLING OTC CFCP PER V1040.002, SEQ ___. 132 NOTE LO2 FLOW WILL BE INITIATED TO OMBUU AND ORBITER TANKS. 14-0536 CFCP JYVO POSITION AND START VIDEO COMM 138 JYVR RECORDING OF OTV CAMERAS 020/120, 021/121, 022/122 FOR V1040.002. PAN CAMERA 020/120 TO FSS/RSS CROSSOVER FLEXHOSES, 021/121 TO OMBUU CARRIER PLATE/VEHICLE I/F AND 022/122 TO LO2/LH2 HP SKID. (SEE CFCP FIGURE 4) 228 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ECS AFT CIRCUIT HIGH FLOWRATE CHECK ----------------------------------- 14-0537 -23H30M OTC CPVD PERFORM ECS AFT CIRCUIT HIGH FLOW 132 RATE CHECK. 1. RECORD AFT FLOW SETPOINT AND TOLERANCE __________LB/MIN 2. ADJUST AFT GN2 FLOWRATE TO 110 +/-5 LBS/MIN 3. RECORD AFT GN2 FLOWRATE ___________LBS/MIN BD 4. RECORD PLB FLOW SETPOINT AND TOLERANCE: ___________LBS/MIN BD 5. IF NOT ADJUSTED, ADJUST PLB FLOWRATE TO 170 +/- 10 LBS/MIN. NOT PERFORMED ______ SS5 6. RECORD PLB FLOWRATE AND I/F PRESSURE. FLOWRATE______LBS/MIN BD I/F PRESSURE______IN. H2O BD RECORD VALUES IN CONSOLE ENGINEERING LOG. 7. ADJUST AFT AND PLB FLOW SETPOINT AND TOLERANCE RECORDED ON SUBSTEPS 1 AND 4 RESPECTIVELY. 14-0538 CPVD OTC ECS AFT CIRCUIT HIGH FLOW RATE 132 CHECK COMPLETE. 229 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0539 -23H30M CFCP OTC LO2 CRYO FLOW COMPLETE AND LO2 132 TANKER FILL LINE INERTED. OTC NTD REQUEST SAFETY CONCURRENCE TO 232 PERFORM LO2 TANKER DISCONNECT. NTD *SCC *SCC *PSE NET 105 14-0540 *PSE *SCC YOU HAVE NTD/SFOC SAFETY PN NET CONCURRENCE TO PROCEED. PERFORM SU72229 105 LO2 TANKER DISCONNECT PER SU72265 *SCC NTD OMI V1040.002 SUPPORT OPERATION 232 SUPPORT SETUP 1. NTD OTC STM OTC CFCP 132 CFCP PRSE STM JSTC 111 JSTC GSPS 114 14-0541 -23H00M GSPS JSTC LO2 TANKER DISCONNECT COMPLETE. PN 114 REQUEST SAFETY CONCURRENCE TO SU72265 JSTC STM REMOVE LO2 TANKER FROM PAD VIA 111 E ROAD AND WEST PERIMETER ROAD. STM NTD SAFETY VERIFY O2 CONCENTRATION 232 ACCEPTABLE FOR LO2 TANKER NTD *SCC REMOVAL. *SCC *PSE NET 105 14-0542 *PSE *SCC O2 CONCENTRATION ACCEPTABLE FOR PN NET LO2 TANKER REMOVAL. YOU HAVE 105 NTD/SAFETY CONCURRENCE TO PROCEED. *SCC NTD LO2 TANKER MAY BE REMOVED FROM 232 PAD SURFACE VIA E ROAD AND WEST NTD OTC PERIMETER ROAD. STM STM JSTC 111 JSTC GSPS 114 230 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0543 *PSE *SCC LO2 TANKER CLEAR OF PAD SURFACE. JSTC NET SU72229 105 *SCC NTD 232 NTD OTC STM STM JSTC 111 NOTE CFCP WILL PERFORM NEXT FIVE STEPS IF EXCESSIVE DECAY OCCURS IN O2 VENT LINE SAMPLE SYSTEM. 14-0544 CFCP OTC PERFORM FOLLOWING: 132 OTC NTD 1. REQUEST NTD/SFOC SAFETY 232 CONCURRENCE FOR PERSONNEL TO NTD *SCC RETURN TO LO2 HIGH PRESSURE *SCC *PSE SAMPLE PNL ON OMBUU TO CLOSE NET PRIMARY AND BACKUP SAMPLE 105 HOKE BOTTLE INLET AND OUTLET VALVES TO PREVENT LOSS OF O2 VENT LINE SAMPLES. O2 VENT LINE SAMPLE HOKES WILL NOT BE REMOVED AT THIS TIME. REQUEST SAFETY VERIFY 02 CONTENT ACCEPTABLE ON OMBUU. 2. VERIFY TECHS WEAR BLUE COLLAR COVERALLS, FACESHIELDS AND LEATHER LOOSE FITTING GLOVES. PERSONNEL REQ'D: SAFETY 1 GSE TECH 1 QC 1 NOT PERFORMED ______ 231 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0545 *PSE *SCC PERSONNEL PROPERLY ATTIRED. 02 NET CONTENT ACCEPTABLE. YOU HAVE 105 SAFETY CONCURRENCE FOR PERSONNEL *SCC NTD TO RETURN TO LO2 SAMPLE 232 PANEL ON OMBUU. NOT PERFORMED ______ 14-0546 OTC CFCP BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. NOT PERFORMED ______ WARNING NEXT TWO STEPS ARE HAZARDOUS DUE TO HIGH PRESSURE O2 FLOW. 14-0547 CFCP OTC PERSONNEL REQUESTED TO CLOSE O2 132 SAMPLE HOKE VALVES ARE NOW OTC NTD LEAVING OMBUU. 232 NTD *SCC NOT PERFORMED ______ 14-0548 *PSE *SCC PERSONNEL REQUIRED TO CLOSE O2 NET SAMPLE HOKE VALVES HAVE CLEARED TO 105 PERIMETER FENCE. *SCC NTD 232 NTD OTC OTC CFCP 132 NOT PERFORMED ______ 232 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- INTERCENTER VOICE CHECKS COMPLETE --------------------------------- 14-0549 -23H00M GYCJ GYCC INTER-CENTER END-TO-END VOICE COMM 117 CHECKS PER OMI D3012 TO SU72201 GYCC STM FOLLOWING LOCATIONS COMPLETE 111 AND COMM CIRCUITS OPERATIONAL: STM NTD 232 1. CCAS (TONE AND VOICE) 2. MILA 3. JSC 4. MSFC-HOSC 5. DFRC 6. TAL SITES (TONE AND VOICE) 7. SLF OIS-Q 8. GSFC 14-0550 JYCJ GYCC INTER-CENTER END-TO-END VOICE COMM 117 CHECK PER D3012 FOR KSC/ROCC GYCC STM POINT-TO-POINTS COMPLETE AND 111 CIRCUITS OPERATIONAL. STM NTD 232 NOTE PERFORM THE FOLLOWING STEP IF SRM SEGMENT RAILCARS WERE RELOCATED FROM BEACH TO BALLOON SIDING. 14-0551 JSTC STM RELOCATION OF _____ SRM SEGMENT SU72254 111 RAILCARS FROM BEACH SIDING TO STM *OPS BALLOON SIDING COMPLETE. 111 (PHONE 1-5108) 232 NTD NOT PERFORMED ______ 233 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD LH2 SERVICING AND ---------------------- SAMPLING (V1040.002 (SEQ _____) ------------------------------- 14-0552 OTC CHGD VERIFY SYSTEMS READY TO SUPPORT PRSD 132 LH2 CRYO LOAD. 14-0553 OTC CHGD PERFORM HGDS MONITORING IN ALL 132 ORBITER AREAS (PAYLOAD BAY, MIDBODY AND AFT). REPORT OUT OF TOLERANCE CONDITIONS TO CFCP ON OIS CH 153. H2 = INCREASE ABOVE BASELINE O2 = INCREASE ABOVE BASELINE 14-0554 OTC CHGD PERFORM LH2 AND FCP HLDS/HFDS 132 MONITORING. REPORT OUT OF TOLERANCE CONDITIONS TO CFCP ON OIS CH 153: HLDS = 10,000 PPM ABOVE BASELINE HFDS = ALARM ON INDICATION 6292 RLDS = 30,000 PPM ABOVE BASELINE LD29 = 10,000 PPM ABOVE BASELINE LD30 = 10,000 PPM ABOVE BASELINE 14-0555 -22H30M CFCP OTC LO2 SERVICING AND SAMPLING SU72228 132 COMPLETE. READY TO PROCEED WITH OTC NTD LH2 SERVICING AND SAMPLING. 232 REQUEST NTD/SFOC SAFETY CONCURRENCE NTD *SCC TO PROCEED. 14-0556 *SCC NTD YOU HAVE SAFETY CONCURRENCE TO 232 FLOW LH2 TO ORBITER PRSD TANKS. 234 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0557 -22H30M NTD OTC YOU HAVE NTD/SFOC SAFETY SU72230 232 CONCURRENCE TO PROCEED. PERFORM OTC CFCP PRSD ORBITER LH2 SERVICING AND 132 SAMPLING PER OMI V1040.002 (SEQ ____). NOTIFYNTD OF ANY FIRE OR LEAKS ABOVE 1 PCT. LH2 TANKER VENT LINE H2 CHECK ----------------------------- 14-0558 -21H00M CFCP OTC LH2 CRYO FLOW COMPLETE AND LH2 SU72231 132 TANKER FILL LINE INERTED. SU72276 OTC NTD PERFORM H2 CONCENTRATION VAPOR 232 CHECK ON H2 VENT HOSE USING NTD *SCC PORTABLE H2 DETECTOR. VERIFY *SCC *PSE H2 CONCENTRATION LESS THAN 1 PCT. NET 105 14-0559 *PSE *SCC H2 VENT CONCENTRATION CHECK NET COMPLETE. H2 CONCENTRATION LESS 105 THAN 1 PCT. YOU HAVE SAFETY *SCC NTD CONCURRENCE TO DISCONNECT LH2 232 TANKER. PRSD LH2 TANKER DISCONNECT -------------------------- 14-0560 NTD STM PERFORM LH2 TANKER DISCONNECT PN 232 OTC PER OMI V1040.002 SUPPORT SU72232 STM JSTC OPERATION SUPPORT SETUP 2. 111 OTC CFCP 132 CFCP PRSE JSTC GSPS 114 235 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- STATUS HGDS/HLDS/HFDS SENSORS ----------------------------- 14-0561 -21H00M NTD OTC STATUS HGDS/HLDS/HFDS SENSORS. SU72233 232 OTC CHGD 132 NOTE FOLLOWING STEP WILL TAKE A FINAL BACKGROUND CHECK OF BOTH THE PAYLOAD BAY AND THE MIDBODY. THIS INFORMATION WILL BE USED AS A REFERENCE POINT FOR THE PRSD INTEGRITY CHECK PERFORMED JUST PRIOR TO ET CRYO TANKING LATER DURING S0007. THE FOLLOWING STEP WILL SAMPLE ZERO GAS, MIDBODY, ZERO GAS, PAYLOAD BAY, ZERO GAS FOR A MINIMUM OF 30 DATA POINTS PER SAMPLE SELECTION. (TEST TIME IS APPROXIMATELY 1 HOUR) 14-0562 OTC CHGD PERFORM FINAL PRSD SYSTEM BACKGROUND 132 CHECK. RECORD RESULTS AS FOLLOWS: INITIAL MIDBODY O2:_____PPM PURGE CIRCUIT 2 R/H:______% INITIAL ZERO: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ MIDBODY: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ MIDDLE ZERO: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ PAYLOAD BAY: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ MIDDLE ZERO: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ PRSD: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ FINAL ZERO: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ FINAL MIDBODY O2:______PPM 236 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0563 -20H30M GSPS JSTC LH2 TANKER DISCONNECT COMPLETE. PN 114 REQUEST SAFETY VERIFY CLEARS ARE JSTC STM DOWN AROUND TANKER AND GIVE 111 CONCURRENCE TO RELEASE TANKER. STM NTD 232 NTD *SCC *SCC *PSE NET 105 14-0564 *PSE *SCC CLEARS AROUND TANKER DOWN, YOU PN NET HAVE SAFETY CONCURRENCE TO SU72267 105 REMOVE LH2 TANKER FROM PAD. *SCC NTD 232 NTD OTC STM STM JSTC 111 JSTC GSPS 114 14-0565 *PSE *SCC LH2 TANKER HAS CLEARED PAD GATE. JSTC NET 105 *SCC NTD 232 STM STM JSTC 111 14-0566 -20H00M CFCP OTC LH2 PRSD SERVICING AND SAMPLING SU72230 132 COMPLETE. OTC NTD 232 NTD *SCC 14-0567 -20H00M CHGD OTC HGDS/HLDS/HFDS SENSOR STATUS 132 COMPLETE. NO ANOMALIES NOTED. OTC NTD 232 NTD *SCC 237 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD GSE INERT PURGE/SAMPLE --------------------------- BOTTLE ISOLATION ---------------- 14-0568 -20H00M CFCP OTC REQUEST SAFETY ESCORT ESSENTIAL SU72235 132 PERSONNEL FROM PAD SURFACE TO SU72277 OTC NTD FSS 155 FT LVL/OMBUU FOR PRSD 232 GSE INERTING/SAMPLE BOTTLE NTD *SCC ISOLATION. REMOVE SAFETY *SCC *PSE CONTROLS ON FSS 155 FT LEVEL AND NET PERFORM O2/H2 LEVEL CHECKS AT 105 OMBUU. VERIFY PERSONNEL PROPERLY ATTIRED AND ESTABLISH 25 FT CLEAR AROUND OMBUU FOR PRSD GSE INERTING /SAMPLE BOTTLE OPERATION REMOVAL. ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- ORB SFOC NASA --- ---- ---- TECH 4 QC 1 SAFETY 1 1 14-0569 *PSE *SCC FSS 155 FT LEVEL SAFETY CONTROLS NET REMOVED AND 25 FT OMBUU CONTROL 105 AREA ESTABLISHED. O2/H2 LEVEL *SCC NTD CHECKS COMPLETE AND ACCEPTABLE, 232 ESSENTIAL PERSONNEL PROPERLY NTD OTC ATTIRED. YOU HAVE SAFETY CONCURRENCE TO PROCEED WITH PRSD GSE INERTING/SAMPLE BOTTLE ISOLATION. 14-0570 OTC CFCP YOU HAVE SAFETY CONCURRENCE TO SU72236 132 *PAD PROCEED WITH GSE INERTING/ SAMPLE BOTTLE ISOLATION. BRIEF PERSONNEL ON HAZARDS AND APPLICABLE SEQUENCES OF APPENDIX Z. 238 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ASSEMBLE ECS SUPPORT PERSONNEL ------------------------------ 14-0571 NTD STM ASSEMBLE ECS DOOR TECHS, ROOM HVAA 232 OTC CREW, AND SFOC SAMPLING PERSONNEL STM JBAC AT PAD GATE. 111 OTC *PAD 132 14-0572 OTC NTD REQUEST SAFETY SUPPORT ESSENTIAL 232 PERSONNEL RETURN TO ECS ROOM FOR NTD *SCC GN2 TO AIR CHANGEOVER (CLOSE AND *SCC *PSE LOCK MANUAL GN2 HAND VALVE). NET 105 14-0573 NTD *SCC ONCE ECS SUPPORT PERSONNEL ASSEMBLED, 232 STM REPORT TO ECS ROOM. *SCC *PSE 105 STM JBAC 111 GN2 TO AIR CHANGEOVER SUPPORT PREPS ----------------------------------- 14-0574 -20H00M NTD STM SUPPORT LPGN2 CHANGEOVER TO PNU 232 AIR PER OPERATION INSTRUCTIONS SU72257 STM JSTC OF M3703 AND OMI V1122. 111 GSPN COORDINATE CHANGEOVER WITH JSTC GSPN CPVD ON CH 172. (1 HR) 114 14-0575 OTC CHGD ORBITER WILL BE PURGED WITH 132 AIR MOMENTARILY, TERMINATE HGDS ORBITER MONITORING. 239 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GN2 TO AIR CHANGEOVER --------------------- NOTE PANELS S72-1107-09 AND S72-1107-10 MAY STILL REQUIRE 150 PSI GN2 TO MLP, TSM, AFT SKIRT 14-0576 -20H00M OTC CPVD PERFORM "GN2 TO AIR CHANGEOVER 132 OPTION A ORBITER SUPPORT" PER OMI V1122. COORDINATE CHANGEOVER WITH GSPN ON CH 172 PRIOR TO CHANGEOVER. RT OMI LOG NO__________ 14-0577 CPVD OTC GN2 TO AIR CHANGEOVER (OPTION A) SU72237 132 CHGD ACCOMPLISHED. ORBITER BEING OTC NTD PURGED WITH AIR AT __________ 232 PTC (RECORD TIME). NTD *SCC *SCC *PSE NET 105 | NOTE | | PERFORM THE FOLLOWING STEP | FOR STS-93. | | 14-0578 PTC OTC AFTER CIRCUIT STABILIZES PERFORM | 132 ORBITER OPERATION SUPPORT SETUP 15 - | OTC CPVD PAYLOAD BAY PURGE VERIFICATION. | CMQC | | NOTIFY PTC IMMEDIATELY IF PURGE | GOES OUT OF SPEC. (STS-93) | | NOT PERFORMED ______| 240 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORBITER VENT DOOR CONFIGURATION ------------------------------- 14-0579 OTC CPVD CONFIGURE VENT DOORS TO ADVERSE SU72238 132 WEATHER PURGE CONFIGURATION. 14-0580 CPVD CURSOR CNTL (VAM31A/VAM09A) COMMAND VENT DOORS TO ADVERSE WEATHER PURGE CONFIGURATION 14-0581 CPVD OTC VENT DOORS IN ADVERSE WEATHER 132 PURGE CONFIGURATION. OTC NTD 232 14-0582 CPVD IF ADJUSTED TO 75-80 LBS/MIN, REDUCE CABIN CIRCUIT FLOW RATE TO 55-60 LBS/MIN. NOT PERFORMED ______ NOTE HAZARDOUS OPERATIONS FOR PRSD CRYO LOADING ARE COMPLETE. 14-0583 CPVD OTC ECS GN2 TO AIR CHANGEOVER SU72239 132 COMPLETE. READY ECS PERSONNEL OTC NTD TO ENTER ECS ROOM TO CLOSE PURGE 232 GN2 ISOLATION VALVES. (V1122) NTD *SCC *SCC *PSE NET 105 14-0584 -20H00M NTD STM SECURE LPGN2 SYSTEM PER M3703 PNU 232 RELEASE PERSONNEL AT INDUSTRIAL STM JSTC SUPPLY INTERFACE. RELEASE GN2 111 PRODUCTION PLANT. JSTC GSPN 114 241 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ECS PERSONNEL RETURN TO ECS ROOM -------------------------------- 14-0585 -20H00M OTC NTD VERIFY O2 CONTENT IN ECS ROOM SU72240 232 ACCEPTABLE AND SAFETY SIGNS NTD *SCC REMOVED. REQUEST SAFETY CONCURRENCE *SCC *PSE TO ENTER ECS ROOM. NET 105 ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- SFOC NASA GSS ---- ---- --- SYS ENGR 1 2 SYS TECH 1 2 QC 1 SAFETY 1 1 14-0586 NTD STM OPEN SOUTH ECS ROOM DOOR AND HVAA 232 RESTRAIN IN OPEN POSITION. SU72259 STM JBAC 111 14-0587 -20H00M *PSE *SCC O2 CONTENT OF ECS ROOM ACCEPTABLE, NET SAFETY SIGNS REMOVED, SAFETY CONCURS 105 WITH ESSENTIAL PERSONNEL RETURNING *SCC NTD TO ECS ROOM. 232 NTD OTC STM OTC *PAD 132 CPVD 242 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TERMINATION OF ECS HAZARDOUS ---------------------------- PURGE GN2 OPERATIONS (V1122) ---------------------------- NOTE WHEN ECS PERSONNEL HAVE BEEN CLEARED TO ENTER ECS ROOM, PERFORM FOLLOWING STEP. 14-0588 -20H00M NTD OTC PERFORM SEQUENCE "TERMINATION OF | 232 ECS HAZARDOUS PURGE GN2 OPERATIONS" OTC CPVD PER OMI V1122 (CLOSE AND LOCK SU72242 | 132 MANUAL GN2 ISO HAND VALVES). RT OMI LOG NO__________ DEPRESS PTCR/ECS ROOM --------------------- 14-0589 -20H00M STM JBAC CONTINUE PTCR/ECS ROOM HVAA 111 DEPRESSURIZATION. (M3034) SU72241 SU72260 14-0590 -19H30M CFCP OTC SAMPLE BOTTLE ISOLATION AND SU72236 132 GSE INERT PURGES COMPLETE. OTC NTD REQUEST SAFETY ESCORT SFOC 232 SAMPLING PERSONNEL TO OMBUU FOR NTD *SCC PRSD SAMPLE BOTTLE DISCONNECT *SCC *PSE AND REMOVAL FROM PAD. NET 105 ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- SFOC NASA ---- ---- TECH 2 QC 1 SAFETY 1 1 243 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0591 *PSE *SCC SAMPLING PERSONNEL PROPERLY SU72247 NET ATTIRED AND CLEARS ESTABLISHED 105 AT OMBUU. YOU HAVE NTD/SAFETY *SCC NTD CONCURRENCE TO PROCEED TO OMBUU 232 FOR SAMPLE BOTTLE DISCONNECT AND NTD OTC REMOVAL FROM PAD. OTC CFCP 132 GN2 HANDVALVES SECURED ---------------------- 14-0592 -19H30M CPVD OTC ECS PURGE GN2 ISOLATION VLVS SU72242 132 CLOSED AND LOCKED. ECS HAZARDOUS OTC NTD GN2 PURGE OPERATIONS COMPLETE. 232 (V1122) NTD *SCC *SCC *PSE NET 105 14-0593 -19H30M NTD *SCC REQUEST SFOC SAFETY PERFORM O2 SU72243 232 CHECK AND VERIFY O2 LEVELS SU72274 *SCC *PSE ACCEPTABLE IN FOLLOWING AREAS: NET 105 1. MLP LEVELS A AND B 2. LOX AND LH2 TSM 3. OAA WHITE ROOM 4. CREW MODULE 5. ORBITER AFT COMPT - IF NOT CLOSED FOR FLIGHT 6. PCR 7. ORBITER MID BODY - IF NOT CLOSED FOR FLIGHT 8. FRCS ROOM - 193 FT LEVEL 9. PTCR 10. OMBUU 244 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0594 NTD *SCC REMOVE SAFETY WARNING SIGNS FROM 232 FOLLOWING AREAS AND REQUEST SAFETY *SCC *PSE CONCURRENCE TO OPEN AREAS FOR NET CONTROLLED WORK. 105 1. MLP ZERO, EAST AND WEST ACCESS PLATFORM STAIRS (SIDE 2 AND 4) 2. FRCS ROOM - 193 FT LEVEL 3.* ORB DOOR 44 4.* ORB 50-1, 50-2 DOORS ACCESS PLATFORM (* = UNLESS CLOSED OUT FOR FLIGHT) 14-0595 *PSE *SCC SAFETY VERIFIES 02 LEVELS NET ACCEPTABLE FOR ENTRY, WARNING 105 SIGNS HAVE BEEN REMOVED AND *SCC NTD YOU HAVE CONCURRENCE TO OPEN 232 CONTROL AREAS FOR CONTROLLED NTD OTC WORK IN FOLLOWING AREAS: PTC TBC 1. MLP LEVELS A AND B STM 2. OAA WHITE ROOM 3. FRCS ROOM - 193 FT LVL 4. PCR 5. PTCR 6. OMBUU 245 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING PRSD TANKS WILL CONTINUE VENTING THRU TSM'S, MLP SIDE 1 (VERANDA) AND FSS 75 FT LVL UNTIL FUEL CELL ACTIVATION. (T-9H00M) FOLLOWING AREAS WILL REMAIN CONTROLLED. ACCESS WILL BE FOR ESSENTIAL PERSONNEL ONLY. (FLAME RETARDANT COVERALLS) 1. MLP SIDE 1 AROUND S70-0686-1 PANEL (5 FT CLEAR AREA) 2. FSS 75 FT LEVEL. GH2 699-1 PNL (5 FT) FOLLOWING AREAS WILL REMAIN CLEARED: 1. ORBITER MIDBODY 2. ORBITER AFT 3. LOX/LH2 TSM THE ONLY EXCEPTION IS FINAL ORDNANCE AND TSM CLOSEOUT FOR LAUNCH. NOTE HAZARDOUS STEPS COMPLETE. ECS GN2 HAS BEEN TERMINATED. TRANSFER ECS CONTROL TO PAD --------------------------- 14-0596 -19H30M OTC CPVD PERFORM "CONTROL STATION | 132 TRANSFER - FIRING ROOM TO PAD" SU72244 | PER OMI V1122. REPORT COMPLETION. | 246 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0597 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO SEC NET OPEN PAD FOR CONTROLLED WORK. SU72250 105 *SCC NTD 232 NTD OTC TBC PTC STM *SEC MOVE TAIR TRAILER ----------------- NOTE DO NOT PERFORM NEXT STEP UNLESS TAIR TRAILER REQUIRED AT PAD. 14-0598 OTC NTD PERFORM SUPPORT OPERATION SUPPORT HESA 232 SETUP 1 TO MOVE TAIR TRAILER SU72269 NTD STM NO.______ FROM ______ TO ______. (1 HR) NOT PERFORMED ______ NOTE PRSD CLOSEOUT OPERATIONS WILL COMMENCE AT THIS TIME. T-19 HR HOLD ANNOUNCEMENT ------------------------- 14-0599 NTD CGLS HOLD CDC AT T-19 HR 00 MIN 00 SEC. 232 14-0600 CGLS HOME CMD KEY - PRESS CDTH -1900/00 XMIT CMD KEY - PRESS 14-0601 CGLS NTD CDC WILL HOLD AT 232 T-19 HR 00 M 00 SEC. 247 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- INGRESS CREW COMPT ------------------ 14-0602 NTD *SCC VERIFY CREW MODULE O2 LEVELS 232 ACCEPTABLE FOR ENTRY. *SCC *PSE NET 105 14-0603 *PSE *SCC CREW MODULE O2 LEVELS ACCEPTABLE NET FOR ENTRY. 105 *SCC NTD NTD OTC 232 14-0604 OTC OMTO WHITE ROOM CEILING 1. VERIFY ORBITER ECS DAMPER A122817 OPEN AND AIR FLOWING THRU ECS DUCT INTO CREW COMPARTMENT. 2. POSITION CHAMBER ECS DAMPER A122818 TO CLOSE POSITION. SECURE WING NUT HAND TIGHT. T:______ 14-0605 -19H30M OTC CDR INGRESS CREW COMPT. SU72245 132 14-0606 OTC JYVR STOP VIDEO RECORDING OF OTV COMM 138 CAMERA 005/105. 14-0607 OTC PLT PANEL R1 132 POWER DISTRIBUTION AC BUS SNSR 1 SW - OFF, 1 SEC THEN AUTO TRIP 2 SW - OFF, 1 SEC THEN AUTO TRIP 3 SW - OFF, 1 SEC THEN AUTO TRIP 14-0608 OTC CDR PNL C3 132 CAUTION/WARNING MODE SW - NORMAL 248 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF DUAL MODE COOLING IS ACTIVE. 14-0609 OTC CECL CONFIGURE FREON LOOPS TO BYPASS 132 FLOW PER ORBITER OPERATION SUPPORT SETUP 8. REPORT COMPLETION. NOT PERFORMED ______ ECLSS GSE COOLING RECONFIGURE ----------------------------- 14-0610 OTC CECL IF S70-1203 IS IN CHILLED WATER, SU72253 | PERFORM: RECONFIGURE GSE COOLING FROM CHILLED WATER TO REFR MODE PER OMI S9001VL2 NOTE PERFORM NEXT STEP FOR SPACEHAB FLIGHTS ONLY. 14-0611 CECL WHEN SPACEHAB POWERED UP, MAINTAIN FCL1 INTERCHANGER INLET TEMP BELOW 50 DEG F. EXCURSIONS ABOVE 50 DEG F ACCEPTABLE PROVIDED EXCURSIONS DO NOT EXCEED 45 MINUTES IN A 3 HOUR PERIOD. OMRSD P095DB.030 NOT PERFORMED ______ 249 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DOWNLINK FMT CHANGE (OPTIONAL) ------------------------------ NOTE PERFORM NEXT FOUR STEPS IF LIFTOFF DOWNLINK IS OTHER THAN 129 AND LIFTOFF FORMAT IS NOT ALREADY ACTIVE. 14-0612 OTC NTD LAUNCH DOWNLINK FORMAT ___ WILL SU72223 232 BE ACTIVATED. SU72252 NTD TBC LPS PTC NOT PERFORMED ______ 14-0613 OTC CDPS ACTIVATE LAUNCH DOWNLINK FORMAT 132 PER OMI V9001VL2 (SPECIAL INSTRUCTIONS). NOT PERFORMED ______ 14-0614 CDPS VERIFY LAUNCH OI FORMAT ACTIVE. NOT PERFORMED ______ 14-0615 CDPS OTC LAUNCH DOWNLINK FORMAT ___ ACTIVATED. 132 OTC NTD 232 NTD PTC NOT PERFORMED ______ 250 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PIC RACK CB RECONFIGURE (OPTIONAL) ---------------------------------- NOTE PERFORM NEXT TWO STEPS IF PIC RACK CBS WERE CLOSED FOR THE T-27HR SHUTTLE PIC RESISTANCE TEST. 14-0616 OTC CEPD PERFORM PIC RACK CB SU72246 132 CONFIGURATION. NOT PERFORMED ______ 14-0617 CEPD QPDS RACK 6814 (COMPT 7A) 151 22D170 (LH2 BURN PIC) CB - OFF (OPEN) RACK 6820 22D260 (LR PIC) CB - OFF (OPEN) RACK 6823 22D280 (LH2 BURN PIC) CB - OFF (OPEN) RACK 6815 22D330 (LR PIC) CB - OFF (OPEN) T:______ NOT PERFORMED ______ 251 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GN2 TO AIR CHANGEOVER COMPLETE ------------------------------ 14-0618 -19H00M GSPN JSTC LPGN2 CHANGEOVER TO AIR PNU 114 COMPLETE. SYSTEM IS SECURED. SU72261 JSTC STM CCF-39 GN2 PRODUCTION PLANT 111 HAS BEEN RELEASED. STM NTD 232 QV:_____ QA 14-0619 STM JSTC START PAD PERIMETER BUS SERVICE. JSTC 111 SU72262 NOTE PERFORM NEXT STEP IF PHONE SERVICE IN PCR REQUIRED FOR PAYLOAD OPERATIONS. 14-0620 -19H00M NTD STM RESTORE PAD A/B LOCKED-OUT PCR COMM 232 TELEPHONES TO SERVICE PER SU72266 STM GYCC OMI D3008. REPORT COMPLETION. 111 GYCC JYCJ 117 NOT PERFORMED ______ 14-0621 OTC *PAD AT OIC MONITOR SHACK ON PAD SU72251 132 SURFACE, REMOVE 'DO NOT USE' TAG AND RESTORE POWER. REPORT COMPLETION. 14-0622 NTD STM ACTIVATE PAD SURFACE OIC COMM 232 MONITOR SHACK ADMIN TELEPHONE SU72256 STM GYCC IN PTCR RM 203. SU72270 111 (PAD A - 861-1151, SW 5; GYCC JYCJ PAD B - 861-1152, SW 9) 117 REPORT COMPLETION. 252 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- T-19 HOUR HOLD -------------- 14-0623 T-19H00M NTD OTC CDC HOLDING AT T-19 HOURS. (HOLDING) PA TBC DURATION OF HOLD WILL BE _____ 232 PTC HOURS _____ MINUTES. *MIL STM *SCC LPS NOTE PERFORM NEXT THREE STEPS AFTER CDC IS HOLDING. 14-0624 NTD CGLS SET CDC TO START COUNTING AT 232 _____ HR _____ MIN _____ SEC GMT. 14-0625 CGLS HOME CMD KEY - PRESS CDTC _____/__.000 HHMM SS XMIT CMD KEY - PRESS 14-0626 CGLS NTD CDC WILL START COUNTING AT _____ 232 HR _____ MIN _____ SEC GMT. LH2 SYSTEM PRE OP SETUPS COMPLETE --------------------------------- 14-0627 CLHY TBC ET PRE-OPERATION SETUP 1 - SU72058 136 LH2 QUALITY SUMMARY SHEET PER G3251 COMPLETE. OMRSD S00FA0.130-1 MPS 4500 PSI GSE ACTIVATION --------------------------- 14-0628 OTC CMPS GO TO CHANNEL 168 AND PERFORM SU72283 132 MPS 4500 PSI GSE ACTIVATION PER OMI V9018.001. 253 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET LH2 LOADING PREPS -------------------- 14-0629 NTD TBC PERFORM FOLLOWING SEQUENCES PER SU72295 232 OMI G3251. TBC CLHY 136 1. LH2 SYSTEM LPS POWERUP 2. LH2 STORAGE AREA VALVE TORQUING 3. LH2 MLP VALVE TORQUING NOTE DO NOT PERFORM NEXT SUBSTEP IF AUTO CYCLING PREVIOUSLY PERFORMED AND NOT REQUIRED. 4. AUTO CYCLING AND HARDWIRE TEST NOT PERFORMED ______ SS4 5. PAD MECHANICAL PREPARATIONS FOR LOADING. 6. LH2 MLP MECHANICAL PREPARATIONS FOR LOADING. 7. FSS MECHANICAL PREPARATIONS FOR LOADING. 254 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0630 CLHY TBC VERIFY FACILITY LPGN2 C/C PNU 136 PIPELINE PRESSURE TBC NTD 150 +0/-10 PSIG. 232 NTD STM STM JSTC 111 JSTC GSPN 114 14-0631 GSPN JSTC FACILITY LPGN2 C/C PIPELINE PNU 114 PRESSURE 150 +0/-10 PSIG. JSTC STM 111 STM NTD 232 NTD TBC TBC CLHY 136 LH2 SYS LPS POWER-UP COMPLETE ----------------------------- 14-0632 CLHY TBC LH2 SYSTEM LPS POWERUP PER 136 G3251 COMPLETE. 255 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET LO2 PREPS FOR VEHICLE LOAD ----------------------------- 14-0633 TBC CLOX PERFORM FOLLOWING PER OMI G3151: SU72294 136 1. CALL TO STATION 2. SYSTEM INITIALIZATION (IF APPLICABLE) 3. LPS/POWER PREPARATIONS AND A126/A127 MOTOR RUNS 4. MLP PREPARATIONS 5. FSS PNEUMATIC PANEL PREPARATIONS 6. FINAL MANUAL PREPARATIONS FOR LOADING 7. LOX SYSTEM ENGINEERING WALKDOWN OMRS S00FA0.116-1 OMRS S00FA0.120-1 OMRS S00FA0.141-1 OMRS S00FB0.330-1 OMRS S00L00.051-B-1 PRSD SAMPLE BOTTLE REMOVAL COMPLETE ----------------------------------- 14-0634 -19H00M CFCP OTC PRSD SAMPLE BOTTLE REMOVAL SU72247 (HOLDING) 132 COMPLETE. 256 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- HGDS/HWS SYSTEM SECURING ------------------------ 14-0635 CHGD OTC RLDS 6292 VERIFIED LESS THAN 132 10,000 PPM IN OMBUU PLATE CAVITY. 14-0636 CHGD CURSOR CNTL (SAW01/HWW21) PUMP 1 - OFF PUMP 3 - OFF MFC POWER - OFF XMIT CURSOR KEY - PRESS 14-0637 CHGD OTC RLDS 6292 CABINET SECURED. 132 14-0638 CHGD OTC ALL SYSTEMS SECURED FROM PRSD 132 CRYO LOAD SUPPORT. NO ANOMALIES NOTED. 14-0639 OTC CHGD CHGD SUPPPORT NO LONGER REQUIRED. 132 GH2/GO2 SAMPLE ANALYSIS ----------------------- 14-0640 -19H00M CFCP OTC NOTIFY WILTECH THAT GH2/GO2 SU72248 (HOLDING) 132 SAMPLES ARE ENROUTE FOR SU72299 OTC NTD ANALYSIS. NEED BY __________ HRS. 232 (PHONE 1-2255) | NTD STM | STM WLTK SAMPLE NO. __________ (PRI GH2) | SAMPLE NO. __________ (B/U GH2) | | SAMPLE NO. __________ (PRI GO2) SAMPLE NO. __________ (B/U GO2) 257 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE ET PRE-OPERATION SETUP 3 ENSURES H2 SAMPLE LINE INSTL FUNCTIONING PROPERLY AND PERFORMED SUFFICIENTLY PRIOR TO LAUNCH TO ALLOW FOR ADJUSTMENTS. NEXT STEP IS TO ASSURE LEAK DETECTION SYSTEM FITS PROPERLY AND MAY BE NOT PERFORMED IF ENGINEERING DETERMINES THAT FIT CHECK IS NOT NECESSARY. 14-0641 TBC CMQC VERIFY ET PRE-OPERATION SETUP 3 - 136 HYDROGEN SNIFFER FIT CHECK COMPLETE. NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF ET 17 IN. HYDROGEN LEAK DETECTORS ALREADY IN PLACE. 14-0642 TBC *PAD PERFORM HYDROGEN LEAK DETECTOR SU72344 136 INSTALLATION AND CHANNELIZATION *PAD CTIF PER OMI T5401. CHGD NOT PERFORMED ______ 14-0643 -19H00M CFCP JYVR STOP VIDEO RECORDING OF OTV COMM (HOLDING) 138 CAMERAS 007/107, 008/108, SU72264 020/120, 021/121, 022/122, 035/135, 036/136, FOR OMI V1040.002 (SEE CFCP FIGURE 4). 258 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD C&W ENABLE --------------- 14-0644 -19H00M OTC CFCP PERFORM PRSD C&W ENABLE PER SU72249 (HOLDING) 132 CDR OMI V1040.002 ON OIS CH 153. (30 MIN) 14-0645 -19H00M CFCP OTC PRSD C&W ENABLE PER V1040.002 | (HOLDING) 132 COMPLETE. 14-0646 OTC CISL PERFORM C&W GOAL SOFTWARE | 132 UPDATE FOR PRSD PARAMETERS | PER OMI S9001VL2. | | 14-0647 -19H00M NTD STM SUPPORT ICE/FROST INITIAL COMM (HOLDING) 232 MAPPING OF ET TPS PER S6444 OTV STM JYVO SETUPS ON OIS CH 222, 223, 224 138 AND 225. CICE WILL CONTACT JYVO WHEN READY FOR CAMERA MOVEMENTS. 14-0648 -19H00M OTC NTD PRSD CRYO SERVICING COMPLETE. PNSA (HOLDING) 232 MAINTAIN FACILITY GH2 AND GO2 NTD STM SYSTEMS FOR NORMAL SUPPORT PER STM JBPN OMI M3020/OMI M3097. NOTE DO NOT PERFORM NEXT STEP UNLESS TAIR TRAILER REQUIRED AT PAD. 14-0649 STM NTD TAIR TRAILER MOVE PER OPERATION 232 SUPPORT SETUP 1 COMPLETE. NTD OTC NOT PERFORMED ______ LH2 GSE VLV TORQUING COMPLETE ----------------------------- 14-0650 CLHY TBC LH2 STORAGE AREA VALVE TORQUING 136 PER G3251 COMPLETE. TBC NTD 232 14-0651 CLHY TBC LH2 MLP VALVE TORQUING PER 136 G3251 COMPLETE. TBC NTD 232 259 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 AUTO CYCLING AND HARDWIRE TEST ---------------------------------- NOTE PERFORM NEXT FOUR STEPS IF LH2 AUTO CYCLING AND HARDWIRE TEST TO BE PERFORMED. 14-0652 CLHY TBC ATTENTION ON PAD ___: 136 TBC NTD THE ET LH2 VENT DISCONNECT CAVITY 232 PURGE WILL OPERATE MOMENTARILY. NTD PA NOT PERFORMED ______ LH2 HARDWIRE TEST ----------------- 14-0653 CLHY TBC VERIFY WIND SPEED FORECAST AT 60 FT 136 LEVEL OF LAUNCH PAD WEATHER TOWER TBC NTD WILL NOT EXCEED 47 KNOTS FOR NEXT 232 HOUR. NTD STM STM JBDY 111 NOT PERFORMED ______ 14-0654 JBDY STM FORECASTED WIND SPEED AT 60 FT LEVEL 111 OF LAUNCH PAD WEATHER TOWER IS STM NTD NOT EXPECTED TO EXCEED 47 KNOTS 232 FOR NEXT HOUR. NTD TBC TBC CLHY 136 OMRSD S00L00.051-A-1 NOT PERFORMED ______ 14-0655 CLHY TBC ATTENTION ON PAD ___: 136 GHE WILL BE VENTED TO LH2 FLARE TBC NTD STACKS. 232 NTD PA NOT PERFORMED ______ 260 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD OFFLOAD OPTION ------------------- NOTE PERFORM NEXT FIVE STEPS ONLY IF PRSD OFF-LOAD IS SCHEDULED. 14-0656 CFCP OTC READY TO PERFORM O2 CRYO TANK SU72305 OTC NTD OFF-LOAD. REQUEST NTD/SFOC SU72297 232 SAFETY CONCURRENCE TO PROCEED. NTD *SCC LO2 DUMP BASIN AND OMBUU TO REMAIN *SCC *PSE CLEAR OF ALL NONESSENTIAL PERSONNEL. NET VERIFY PERSONNEL PROPERLY ATTIRED 105 IN LONG SLEEVE, BLUE COLLAR FLAME RETARDANT COVERALLS, LEATHER GAUNTLET GLOVES AND FACESHIELDS. NOT PERFORMED ______ 14-0657 *PSE *SCC OMBUU AND O2 DUMP BASIN CONTROL 105 AREAS CLEARED OF NONESSENTIAL *SCC NTD PERSONNEL. YOU HAVE NTD/SFOC 232 SAFETY CONCURRENCE TO PROCEED. NTD OTC NOT PERFORMED ______ WARNING HAZARDOUS STEPS FOLLOW DUE TO LO2 OFFLOAD OPERATIONS. 14-0658 OTC CFCP PERFORM O2 CRYO TANK OFF-LOAD. NOT PERFORMED ______ 261 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0659 CFCP OTC LO2 OFFLOAD COMPLETE. READY 132 TO PROCEED WITH LO2 SYSTEM OTC NTD SECURING. 232 NOT PERFORMED ______ 14-0660 CFCP OTC LO2 OFFLOAD AND SECURING SU72305 132 COMPLETE. OTC NTD NOT PERFORMED ______ 232 262 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- **** START PRSD CLOSEOUT OPERATIONS **** NOTE PRSD LOAD AND, IF REQUIRED, OFFLOAD MUST BE COMPLETE PRIOR TO PERFORMANCE OF FOLLOWING 37 STEPS. OMBUU CLOSEOUT OPERATIONS ------------------------- NOTE DO NOT PERFORM NEXT TWO STEPS IF FIRE AND EMS ALREADY RELEASED. 14-0661 NTD *SCC REQUEST SFOC SAFETY CONCURRENCE 232 TO RELEASE FIRE AND MEDICAL *SCC *PSE FROM PRSD SUPPORT. NET 105 NOT PERFORMED ______ 14-0662 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO FIRE NET RELEASE FIRE AND EMS FROM PRSD SU72197 105 SUPPORT. *SCC NTD 232 NTD STM STM JSTC 111 JSTC JFIR 114 NOT PERFORMED ______ 14-0663 NTD *SCC TURN PAD ___, A/B-5 AND A/B-11 232 ROADBLOCK FLASHING AMBER LIGHTS *SCC *PSE OFF. NET 105 263 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0664 CFCP OTC READY TO PROCEED WITH 132 MIDBODY UMBILICAL OPERATIONS. OTC NTD REQUEST SAFETY CONCURRENCE TO 232 PROCEED (V3538, TASK 03). NTD *SCC *SCC *PSE NET 105 14-0665 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO NET PROCEED WITH OMBUU DEMATE PREPS. 105 *SCC NTD 232 NTD OTC 14-0666 NTD *SCC REQUEST SAFETY OPEN LO2 DUMP SU72297 232 BASIN FOR CONTROLLED WORK UPON *SCC *PSE COMPLETION OF O2 CHECKS. NET 105 14-0667 OTC CFCP PERFORM PRSD PREPS FOR MIDBODY SU72284 132 UMBILICAL DEMATE PER OMI V1040.002. 264 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 6292 CABINET PURGE TERMINATION ------------------------------ 14-0668 CFCP PUOD RSS OMBUU ROOF - 6292 CABINET GN2 PURGE VALVE A505975 - CLOSE (CW) T:______ 14-0669 CFCP OTC PRSD PREPS FOR OMBUU DEMATE SU72284 132 COMPLETE. READY TO SUPPORT MIDBODY UMBILICAL CARRIER PLATE DEMATE AHC FLIGHT CAP INSTALLATION PER V3538 (TASK 03). 14-0670 OTC NTD REQUEST SFOC SAFETY CLEAR SU72285 232 NONESSENTIAL PERSONNEL FROM AREA SU72306 NTD *SCC 10 FT RADIUS ADJACENT TO AND *SCC *PSE DIRECTLY BELOW MID LEVEL NET EXTENSIBLE PLATFORM AND VERIFY ALL 105 ESSENTIAL PERSONNEL WITHIN A 10 FT RADIUS OF CARRIER PLATE ARE WEARING LONG SLEEVED, BLUE COLLAR FLAME RETARDANT COTTON COVERALLS, LEATHER GLOVES, FACESHIELDS. CLEAR NONESSENTIAL PERSONNEL IN SUPPORT OF MIDBODY UMBILICAL DEMATE PER V3538 (15 MIN.). REQUEST SAFETY CONCURRENCE TO PROCEED. ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- ORB SFOC NASA --- ---- ---- ENG/SUPR 1 TECHNICIAN 4 QUALITY 2 SAFETY 1 1 265 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0671 NTD ATTENTION ON PAD ___: PA ALL NONESSENTIAL PERSONNEL CLEAR 10 FT RADIUS OF CARRIER PLATE AND 10 FT RADIUS DIRECTLY BELOW MID-LEVEL EXTENSIBLE PLATFORM IN SUPPORT OF MIDBODY UMBILICAL DEMATE. ORBITER MIDBODY UMBILICAL DEMATE -------------------------------- 14-0672 *PSE *SCC LOCAL CONTROL AREA ESTABLISHED NET FOR UMBILICAL DEMATE. PERSONNEL 105 PROPERLY ATTIRED. YOU HAVE *SCC NTD SAFETY CONCURRENCE TO PROCEED. 232 NTD OTC 14-0673 OTC PGSS BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. WARNING NEXT STEP IS HAZARDOUS BECAUSE PERSONNEL COULD BE EXPOSED TO HYDROGEN, OXYGEN, NITROGEN AND/OR HELIUM GAS. ACCESS TO AND FROM 50-1 DOOR AREA AND OMBUU MUST BE TERMINATED UNTIL FLIGHT CAPS ARE INSTALLED ON VEHICLE. 14-0674 OTC PGSS PERFORM MIDBODY UMBILICAL SU72286 132 *PAD DEMATE AND PRSD AHC FLIGHT CAP INSTALLATION PER OMI V3538 ON OIS CH 153. RT OMI LOG NO.__________ 14-0675 *PAD OTC MIDBODY UMBILICAL DEMATE AND 132 PRSD AHC FLIGHT CAP INSTALLATION OTC CFCP COMPLETE. READY FOR AHC FLIGHT 132 CAP LEAK CHECKS. 232 NTD 266 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0676 NTD *SCC ORBITER MIDBODY UMBILICAL DEMATE 232 COMPLETE. REQUEST SAFETY SUPPORT *SCC *PSE ON OMBUU WITH PORTABLE O2/H2 LEAK NET DETECTOR FOR PRSD AHC FLIGHT CAP 105 LEAK CHECKS. NOTE HAZARDOUS OPERATION - MIDBODY UMBILICAL DEMATE COMPLETE. PRSD AHC FLIGHT CAPS LEAK CHECK ------------------------------- (V1040.002 SEQ ___) ------------------- 14-0677 OTC CFCP PERFORM LEAK CHECK OF PRSD AHC SU72287 132 FLIGHT CAPS PER OMI V1040.002 ON OIS CH 153. 14-0678 CFCP OTC PRSD FLT CAP LEAK CHECKS SU72306 132 COMPLETE. REQUEST CONCURRENCE OTC NTD TO OPEN OMBUU CONTROL AREA. 232 NTD *SCC *SCC *PSE NET 105 14-0679 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO NET OPEN OMBUU CONTROL AREA FOR 105 CONTROLLED WORK. *SCC NTD 232 NTD OTC NOTE HAZARDOUS OPERATIONS - PRSD FLIGHT CAP LEAK CHECK COMPLETE. 14-0680 CFCP OTC READY FOR CLOSEOUT OF MIDBODY SU72288 132 UMBILICAL DOOR 45. OTC NTD 232 267 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0681 OTC *PAD PERFORM ORBITER DOOR 45 132 INSTALLATION, PRE-FLIGHT UMB MID FUSELAGE PER: JC V80-94500 -DOOR 45, PRE-FLIGHT UMBILICAL PANEL ACCESS, INSTALLATION. 14-0682 *PAD OTC ORBITER DOOR 45 INSTALLATION 132 COMPLETE. 14-0683 OTC *PAD START VERIFICATION OF ORBITER SU72464 | DOOR PANEL CONFIGURATION FOR TANKING AND LAUNCH PER ORBITER OPERATION SUPPORT SETUP 2. PART B MUST BE COMPLETE BY T-11H00M. GSE PREPS FOR FUEL CELL ACTIVATION ---------------------------------- NOTE PERFORM NEXT TWO STEPS UPON COMPLETION OF GO2 RECHARGE OPERATIONS (IF PERFORMED). 14-0684 NTD OTC PERFORM FINAL GSE PREPS FOR FUEL SU72320 232 CELL ACTIVATION. OTC CFCP 132 NOT PERFORMED ______ 14-0685 CFCP OTC FINAL GSE PREPS FOR FUEL CELL 132 ACTIVATION COMPLETE. (V1040.002) NOT PERFORMED ______ 14-0686 CFCP OTC PRSD SAMPLE RESULTS ARE SATISFACTORY. 268 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OMBUU ROOF EXTENSIBLE PLATFORM ------------------------------ RETRACTION/MIDLEVEL EXTENSIBLE ------------------------------ PLATFORM RETRACTION ------------------- 14-0687 OTC *PAD PERFORM OMBUU SECURING PER SU72322 132 OMI V3538. (TASK 5) 14-0688 CFCP OTC OMBUU SECURING COMPLETE. 132 OTC NTD 232 14-0689 OTC *PAD VERIFY READY TO SUPPORT OMBUU 132 PLATFORM RETRACT PER V3538. 14-0690 OTC *PAD BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE *PAD PMTG SEQUENCES OF APPENDIX Z. 14-0691 OTC *PAD RETRACT OMBUU PLATFORMS PER 132 OMI V3529. OMBUU PLATFORM RETRACTION COMPLETE ---------------------------------- 14-0692 *PAD OTC OMBUU PLATFORM RETRACTION PER 132 V3529 COMPLETE. OTC NTD 232 NTD *SCC *SCC *PSE NET 105 *** END PRSD CLOSEOUT OPERATIONS *** 269 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF LH2 AUTO CYCLING AND HARDWIRE TEST PERFORMED. 14-0693 CLHY TBC AUTO CYCLING AND HARDWIRE TEST 136 PER G3251 COMPLETE. TBC NTD 232 NOT PERFORMED ______ 14-0694 *PAD OTC PRE-OPERATION SETUP 14 - OMS 132 QUANTITY GAGING CHECKS COMPLETE. 270 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM GO2 RECHARGE OPTION IF GO2 STORAGE PRESSURE 4400 PSIG OR BELOW. GO2 RECHARGE OPTION ------------------- NOT PERFORMED ______ 14-0695 JBPN STM READY TO PROCEED WITH FACILITY PN 111 GO2 RECHARGE OPERATIONS PER PNSA STM NTD M3097. REQUEST ESSENTIAL FIRE 232 PERSONNEL REPORT ON STATION. SU72350 STM JSTC REQUEST SAFETY CONCURRENCE. SU72375 111 JSTC GSPS NET 104 114 JFIR 14-0696 NTD *SCC REQUEST SFOC SAFETY CLEAR ALL 232 NONESSENTIAL PERSONNEL 150 FT RADIUS *SCC *PSE FROM GO2 STORAGE BATTERY FOR GO2 NET RECHARGE OPERATIONS. VERIFY 105 ESSENTIAL PERSONNEL PROPERLY ATTIRED IN CLEAN FLAME RETARDANT NON-STATIC PRODUCING COVERALLS AND NON- SPARKING FOOTWEAR. VERIFY FIRE SUPPORT ON SITE AND EMERGENCY MEDICAL ON STANDYBY. VERIFY SAFETY CONCURRENCE TO PROCEED. ESSENTIAL PERSONNEL ------------------- SFOC JBOSC WILTECH NASA ---- ----- ------- ---- FIRE DEPT 3 ENGINEER 1 1 TECH 3 3 QUAL 1 SAFETY 1 SAMPLING 2 271 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0697 NTD ATTENTION ON PAD _____: PA ALL NONESSENTIAL PERSONNEL CLEAR 150 FT RADIUS FROM GO2 STORAGE BATTERY AREA FOR GO2 RECHARGE OPERATION. 14-0698 *PSE *SCC ALL NONESSENTIAL PERSONNEL HAVE PN NET BEEN CLEARED FROM CONTROL AREA. PNSA 105 PERSONNEL ARE PROPERLY ATTIRED. *SCC NTD FIRE SUPPORT ON SITE, EMERGENCY 232 MEDICAL ON STANDBY AND COMM CHECK NTD STM COMPLETE. YOU HAVE SAFETY STM JBPN CONCURRENCE TO PROCEED WITH GO2 111 JSTC RECHARGE OPERATION (M3097). JSTC GSPS NET 104 14-0699 STM JBPN BRIEF PERSONNEL ON HAZARDS THAT PNSA 111 WILL BE PRESENT AND APPLICABLE JBPN GBPN SEQUENCES OF APPENDIX Z. NET 104 WARNING HAZARDOUS GAS FLOW OPERATIONS FOLLOW DUE TO PRESENCE OF GO2. 14-0700 JBPN GBPN ON PANEL S70-0826-1, CLOSE PNSA NET VALVE A81164. REPORT COMPLETION. 104 14-0701 GBPN JBPN VALVE A81164 CLOSED. PNSA NET 104 14-0702 JBPN STM GO2 SUPPLY VALVE A81164 IS PNSA 111 CLOSED. GO2 SUPPLY WILL NOT BE STM NTD AVAILABLE TO PRSD/ECLS 232 SYSTEMS UNTIL GO2 RECHARGE NTD OTC OPERATION COMPLETE (8 HR). OTC CFCP 132 CECL 14-0703 JBPN STM STARTING WITH G02 RECHARGE PNSA 111 OPERATIONS PER M3097. 272 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0704 JBPN STM GO2 RECHARGE OPERATIONS SECURED. PNSA 111 PROCEEDING WITH SAMPLING OPERATIONS. STM NTD FIRE/RESCUE SUPPORT MAY BE RELEASED 232 TO IN-STATION SUPPORT DURING SAMPLING AND SAFETY CONTROLS MAY BE REDUCED TO 25 FT AROUND GO2 AREA. 14-0705 NTD *SCC GO2 RECHARGE OPERATIONS SECURED FOR 232 FOR SAMPLING. REQUEST SAFETY REDUCE *SCC *PSE CONTROLS FROM 150 FT TO 25 FT AROUND NET GO2 BATTERY AND CONCURRENCE TO 105 RELEASE FIRE/RESCUE TO IN-STATION SUPPORT. 14-0706 *PSE *SCC FIRE/RESCUE AT GO2 RELEASED TO FIRE NET IN-STATION SUPPORT FOR SAMPLING 105 OPERATIONS (M3097). *SCC NTD 232 NTD STM STM JSTC 111 JSTC JFIR 114 14-0707 *PSE *SCC GO2 AREA CONTROLS REDUCED FROM PNSA NET 150 FT TO 25 FT FOR SAMPLING 105 OPERATIONS. *SCC NTD 232 NTD STM STM JBPN 111 14-0708 JBPN STM GO2 RECHARGE OPERATIONS PNSA 111 COMPLETE. SAMPLE RESULTS PASS STM NTD GO2 SPECIFICATION SE-S-0073, TABLE 232 6.3-4 OXYGEN. REQUEST CONCURRENCE NTD OTC TO PROCEED WITH GO2 LINE OTC CFCP PRESSURIZATION. REQUEST CFCP 132 ISOLATE S70-0830-1 PNL TO SUPPORT GO2 CC LINE PRESSURIZATION AND LEAK CHECKS. 14-0709 CFCP PSOM S70-0830-1 PNL A88560 MV - CLOSE (CW) T:______ 273 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0710 CFCP OTC GO2 FACILITY ISOLATION VALVES PNSA 132 CLOSED. OTC STM STM JBPN 111 JBPN GBPN NET 104 14-0711 STM NTD REQUEST SAFETY CONCURRENCE TO 232 PERFORM GO2 LINE PRESSURIZATION. NTD *SCC REQUEST SAFETY CLEAR ALL *SCC *PSE NONESSENTIAL PERSONNEL FROM 25 FOOT NET RADIUS FROM GO2 BATTERY. ESTABLISH 105 BARRICADES AND WARNING SIGNS IF REQUIRED. VERIFY PERSONNEL PROPERLY ATTIRED IN FLAME RETARDANT COVERALLS. ESSENTIAL PERSONNEL ------------------- GSS NASA SFOC --- ---- ---- ENGR 1 TECH 2 QUALITY 1 SAFETY 1 1 14-0712 NTD ATTENTION ON PAD _____: PA ALL NONESSENTIAL PERSONNEL CLEAR CONTROL AREA 25 FOOT RADIUS AROUND GO2 BATTERY FOR G02 LINE PRESSURIZATION. 14-0713 *PSE *SCC GO2 BATTERY CLEARED OF NONESSENTIAL NET PERSONNEL. ESSENTIAL PERSONNEL 105 PROPERLY ATTIRED. YOU HAVE SAFETY *SCC NTD CONCURRENCE TO PROCEED WITH GO2 232 LINE PRESSURIZATION. SAFETY NTD STM VERIFIES FIRE SUPPORT. 14-0714 OTC CFCP BRIEF PERSONNEL ON HAZARDS THAT 132 STM WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. 274 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING FOLLOWING STEPS HAZARDOUS DUE TO GO2 LINE PRESSURIZATION. 14-0715 STM JBPN PERFORM GO2 LINE PRESSURIZATION PNSA 111 PER M3097. JBPN GBPN NET 104 NOTE HAZARDOUS OPERATIONS DUE TO GO2 LINE PRESSURIZATION COMPLETE. 14-0716 STM NTD FACILITY GO2 LINE PRESSURIZATION 232 COMPLETE. GO2 SUPPLY IN SUPPORT. 111 CMQC NTD OTC 232 OTC CFCP 132 14-0717 CFCP PSOM S70-0830-1 PNL A88560 MV - SLOWLY OPEN (CCW) T:______ 14-0718 JBPN STM REQUEST SAFETY CONCURRENCE TO PNSA 111 OPEN CONTROL AREA AROUND GO2 STM NTD STORAGE BATTERY. 232 NTD *SCC *SCC *PSE NET 105 275 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0719 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO FIRE NET OPEN CONTROL AREA AROUND GO2 105 STORAGE BATTERY FOR CONTROLLED *SCC NTD WORK. RELEASE FIRE AND EMERGENCY 232 MEDICAL SUPPORT. NTD STM STM JSTC 111 JSTC JFIR 114 GO2 RECHARGE OPTION COMPLETE ---------------------------- NOTE PERFORM GO2 SYSTEM TOP-OFF OPTION UPON REQUEST OF PNEUMATICS ENGINEERING, UTILIZING A COMPRESSED GAS TRAILER AS GO2 SOURCE. GO2 SYSTEM TOP-OFF OPTION ------------------------- NOT PERFORMED ______ 14-0720 STM JSTC PROVIDE 6000 PSI GO2 TUBE BANK PN 111 PAD___ HPG BATTERY. JSTC GSPS 114 14-0721 JBPN STM READY TO PROCEED WITH FACILITY PNSA 111 GO2 TOP-OFF OPERATIONS PER M3097. STM NTD REQUEST ESSENTIAL PERSONNEL REPORT 232 ON STATION. REQUEST SAFETY CONCURRENCE. 276 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0722 NTD *SCC REQUEST SAFETY CLEAR NONESSENTIAL 232 PERSONNEL FROM 25 FT RADIUS OF GO2 *SCC *PSE STORAGE BATTERY FOR HAZARDOUS GO2 NET OPERATIONS. VERIFY ESSENTIAL 105 PERSONNEL WITHIN CONTROLLED AREA WEAR CLEAN, NONSTATIC PRODUCING, FLAME RETARDANT COVERALLS. REQUEST SAFETY CONCURRENCE TO PROCEED. ESSENTIAL PERSONNEL ------------------- SFOC NASA ---- ---- MECHANIC 3 ENGINEER 1 1 SAFETY 1 1 14-0723 NTD ATTENTION ON PAD___: PA ALL NONESSENTIAL PERSONNEL CLEAR 25 FT RADIUS FROM GO2 BATTERIES | FOR HAZARDOUS GO2 OPERATIONS. 14-0724 *PSE *SCC GO2 BATTERY CLEARED OF NONESSENTIAL NET PERSONNEL. ESSENTIAL PERSONNEL 105 PROPERLY ATTIRED. YOU HAVE SAFETY *SCC NTD CONCURRENCE TO PROCEED WITH GO2 232 TOP-OFF. NTD STM 277 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING HAZARDOUS OPERATIONS FOLLOW DUE TO HIGH PRESSURE PNEUMATICS AND POSSIBLE OXYGEN RICH ATMOSPHERE. 14-0725 STM JBPN PERFORM GO2 SYSTEM TOP-OFF PER PNSA 111 OMI M3097. BRIEF PERSONNEL OF SU72350 HAZARDS INVOLVED AND REVIEW APPLICABLE APPENDIX Z EMERGENCY INSTRUCTIONS. 14-0726 JBPN STM GO2 SYSTEM TOP-OFF OPERATION PNSA 111 COMPLETE. REQUEST SAFETY SU72375 STM NTD CONCURRENCE TO OPEN CONTROL 232 AREA AROUND GO2 STORAGE BATTERY. NTD *SCC *SCC *PSE NET 105 14-0727 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO PNSA NET OPEN CONTROL AREA AROUND GO2 105 STORAGE BATTERY FOR CONTROLLED *SCC NTD WORK. 232 NTD STM STM JBPN 111 GO2 SYSTEM TOP-OFF OPTION COMPLETE ---------------------------------- 14-0728 STM QBSE PICK UP ANY LOOSE ITEMS/DEBRIS STSA | NET FROM SRB HAUNCH AREAS. REMOVE 104 HAUNCH ACCESS LADDERS PER OMI M3083. 278 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT STEP IF ACCOMPLISHED BY ANOTHER DOCUMENT. 14-0729 STM QBSE PERFORM RSS X-1 DAY CHECKS STSA | NET (M3094). REPORT COMPLETION. | 104 NOT PERFORMED ______ FRCS THRUSTER COVER CONFIGURATION --------------------------------- FOR LAUNCH ---------- WARNING HAZARDOUS STEPS FOLLOW DUE TO POSSIBLE EXPOSURE TO N2O4 AND MMH. SFOC SAFETY SHALL MONITOR BREATHING ZONES FOR TOXIC LEVELS AND IF TLV IS EXCEEDED, EVACUATE PERSONNEL TO A SAFE AREA. 14-0730 *PAD OTC REQUEST SFOC SAFETY CLEAR ALL SU72290 132 PERSONNEL 275 LEVEL AND ABOVE SU72308 OTC NTD (INCLUDING GVA). CLEAR NONESSENTIAL 232 PERSONNEL 10 FT RADIUS AROUND NTD *SCC FRCS RSS 207 FT LEVEL. VERIFY *SCC *PSE ESSENTIAL PERSONNEL PROPERLY NET ATTIRED IN RUBBER APRON, FACESHIELD AND HYPER COMPATIBLE GLOVES. SAFETY PERFORM BREATHING ZONE CHECKS DURING FRCS THRUSTERS COVER REMOVAL. CLEAR WILL BE EXPANDED TO 20 FT RADIUS AND SAR FOR VERNIER THRUSTERS. ESSENTIAL PERSONNEL ------------------- ORB NASA SFOC --- ---- ---- ENGR 1 1 TECH 3 QUALITY 1 1 SAFETY 1 1 279 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0731 NTD ATTENTION ON PAD ___: PA ALL PERSONNEL CLEAR FSS 275 FT LEVEL AND ABOVE (INCLUDING GVA) AND NONESSENTIAL PERSONNEL CLEAR A 10 FT RADIUS OF FWD RCS FOR THRUSTER COVER REMOVAL. 14-0732 NTD STM VERIFY LIFE SUPPORT ON SITE AND LS 232 THREE EACH BREATHING AIR LINES SU72302 | STM JSTC WITH MASK AND COMM AT 107/207 FT | 111 FOR RCS THRUSTER COVER CONFIG | JSTC *SCB (ORBITER OPERATION SUPPORT SETUP 23). | 114 14-0733 OTC *PAD BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE *PAD OMTO SEQUENCES OF APPENDIX Z. 14-0734 *PSE *SCC NONESSENTIAL PERSONNEL HAVE BEEN NET CLEARED FROM CONTROL AREAS FOR 105 FRCS THRUSTER COVER REMOVALS. *SCC NTD ESSENTIAL PERSONNEL PROPERLY 232 ATTIRED IN RUBBER APRONS, FACESHIELD NTD OTC AND HYPER COMPATIBLE GLOVES. SAFETY VERIFIES CONCURRENCE TO PROCEED WITH THRUSTER COVER REMOVALS. 14-0735 OMTO *PAD TASK TEAM LEADER/DESIGNEES *PAD OTC CONDUCT HAZARDOUS OPERATIONS AND 132 APPENDIX Z BRIEFINGS. TTL:____ 14-0736 OTC *PAD PERFORM ORBITER OPERATION 132 SUPPORT SETUP 23 PART A - FRCS THRUSTER COVER CONFIGURATION FOR LAUNCH. (1.5 HR) 14-0737 *PAD OTC FRCS THRUSTER UTPA REMOVALS 132 COMPLETE PER ORBITER OPERATION OTC NTD SUPPORT SETUP 23. REQUEST SAFETY 232 PERFORM TVC'S AND OPEN CONTROL NTD *SCC AREAS. *SCC *PSE NET 105 280 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0738 *PSE *SCC N2O4 AND MMH TOXIC VAPOR CHECKS SU72308 NET COMPLETE AND LEVELS ACCEPTABLE. 105 YOU HAVE SAFETY CONCURRENCE TO *SCC NTD OPEN HYPERGOLIC CONTROL AREA FOR 232 CONTROLLED WORK. NTD OTC OTC *PAD 132 NOTE FRCS HAZARDOUS OPERATIONS COMPLETE. 14-0739 *PAD OTC CONTINUING WITH FRCS RAIN COVER 132 INSTALLATION PER ORBITER OPERATION SUPPORT SETUP 23 PART A. 14-0740 *PAD OTC FRCS RAIN COVER INSTALLATION SU72290 132 COMPLETE PER ORBITER OPERATION SUPPORT SETUP 23 PART A. 14-0741 OTC NTD BREATHING AIR LINES NO LONGER 232 REQUIRED IN THE FRCS ROOM NTD STM (RSS 207 FT) FOR ORBITER STM JSTC OPERATION SUPPORT SETUP 23. 111 SUPPORT RELEASED. JSTC *SCB 114 281 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ARCS THRUSTER COVER CONFIGURATION --------------------------------- WARNING HAZARDOUS STEPS FOLLOW DUE TO POSSIBLE EXPOSURE TO N2O4 AND MMH. SFOC SAFETY SHALL MONITOR BREATHING ZONES FOR TOXIC LEVELS AND IF TLV IS EXCEEDED, EVACUATE PERSONNEL TO A SAFE AREA. 14-0742 *PAD OTC REQUEST SFOC SAFETY CLEAR ALL SU72309 132 PERSONNEL 275 LEVEL AND ABOVE SU72281 | OTC NTD (INCLUDING GVA). CLEAR NONESSENTIAL 232 PERSONNEL 10 FT RADIUS OF AFT RCS NTD *SCC THRUSTERS ON RSS 107 FT LEVEL, *SCC *PSE RSS 107 FT LEVEL AND ENGINE NET SERVICE PLATFORM. VERIFY ESSENTIAL 105 PERSONNEL PROPERLY ATTIRED IN IN RUBBER APRON, FACESHIELD AND HYPER COMPATIBLE GLOVES. SAFETY PERFORM BREATHING ZONE CHECKS DURING THRUSTERS UTPA REMOVAL. REQUEST SFOC SAFETY CONCURRENCE TO PROCEED. ESSENTIAL PERSONNEL ------------------- ORB NASA SFOC --- ---- ---- ENGR 1 1 TECH 3 QUALITY 1 1 SAFETY 1 1 282 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0743 *PAD BRIEF PERSONNEL ON HAZARDS THAT WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. 14-0744 NTD ATTENTION ON PAD ___: PA ALL NONESSENTIAL PERSONNEL CLEAR 10 FT RADIUS OF AFT RCS THRUSTERS ON RSS 107 FT LEVEL , RSS 120 FT LEVEL, ENGINE SERVICE PLATFORM AND FSS 275 FT LEVEL AND ABOVE (INCLUDING GVA). 14-0745 *PSE *SCC NONESSENTIAL PERSONNEL HAVE BEEN NET CLEARED FROM CONTROL AREAS FOR 105 ARCS THRUSTER COVER REMOVALS. *SCC NTD ESSENTIAL PERSONNEL PROPERLY 232 ATTIRED IN RUBBER APRONS, FACESHIELD NTD OTC AND HYPER COMPATIBLE GLOVES. SAFETY VERIFIES CONCURRENCE TO PROCEED WITH ARCS THRUSTER COVER REMOVALS. 14-0746 OMTO *PAD TASK TEAM LEADER/DESIGNEES *PAD OTC CONDUCT HAZARDOUS OPERATIONS AND 132 APPENDIX Z BRIEFINGS. TTL:____ 14-0747 OTC *PAD PERFORM ORBITER OPERATION SUPPORT 132 SETUP 23 PART B -ARCS THRUSTER COVER CONFIGURATION FOR LAUNCH. (2.5 HR) 14-0748 *PAD OTC ORBITER ARCS THRUSTER UTPA 132 REMOVAL OPS COMPLETE PER ORBITER OTC NTD OPERATION SUPPORT SETUP 23 PART B. 232 READY FOR TOXIC CHECKS OF ALL AFT NTD *SCC THRUSTERS, RSS 107 FT LEVEL, OVERHEAD *SCC *PSE ON RSS 120 FT LEVEL, 275 FT LEVEL AND NET ABOVE, AND SSME ESP. REQUEST CONCURRENCE 105 TO OPEN CONTROL AREA FOR CONTROLLED WORK. 283 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0749 *PSE *SCC N2O4 AND MMH TOXIC VAPOR CHECKS SU72309 | NET COMPLETE AND LEVELS ACCEPTABLE. 105 YOU HAVE SAFETY CONCURRENCE TO *SCC NTD OPEN HYPERGOLIC CONTROL AREA FOR 232 CONTROLLED WORK. NTD OTC OTC *PAD 132 NOTE ARCS HAZARDOUS OPERATIONS COMPLETE. 14-0750 *PAD OTC CONTINUING WITH ARCS RAIN COVER 132 INSTALLATION PER ORBITER OPERATION SUPPORT SETUP 23 PART B. 14-0751 *PAD OTC ARCS RAIN COVER INSTALLATION SU72281 | 132 COMPLETE PER ORBITER OPERATION SUPPORT SETUP 23 PART B. REPOSITION RSS ET ACCESS PLTFMS ------------------------------- NOTE PERFORM NEXT TWO STEPS IF NOT PREVIOUSLY ACCOMPLISHED BY SCHEDULE/OTHER DOCUMENT. 14-0752 STM NTD VERIFY NO ACTIVE PURGE FROM ET 232 INTERTANK. NTD TBC TBC CLHY 136 CLOX NOT PERFORMED ______ 14-0753 NTD STM REPOSITION RSS ET ACCESS PLTFMS STSA | 232 TO STOWED POSITION PER OMI M3169. SU72370 STM QBSE (2 HRS) (TASKS 14,1,2,3) NET 104 NOT PERFORMED ______ 284 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RESUME CDC ---------- 14-0754 T-19H00M NTD OTC CDC WILL START COUNTING AT T-19 HR (HOLDING) PA TBC IN FIVE MINUTES. 232 *MIL STM *SCC LPS PTC 14-0755 T-19H00M NTD ALL CDC AT T-19 HR AND COUNTING. (COUNTING) 232 PA LH2 PAD MECHANICAL PREPS COMPLETE --------------------------------- 14-0756 CLHY TBC PAD MECHANICAL PREPARATIONS FOR 136 LOADING PER G3251 COMPLETE. MPS 4500 PSI GSE ACTIVATION COMPLETE ------------------------------------ 14-0757 CMPS OTC MPS 4500 PSI GSE ACTIVATION PER SU72283 132 V9018.001 COMPLETE. NOTE DO NOT PERFORM NEXT FOUR STEPS IF AFT FUSELAGE CLOSED. 14-0758 CLHY TBC READY TO ACTIVATE ORBITER/ET 136 DISCONNECT CAVITY PURGE. VERIFY ALL PERSONNEL CLEARED FROM INSIDE OF AFT FUSELAGE AND SAFETY CONCURRENCE TO PROCEED PER G3251. NOT PERFORMED ______ 285 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0759 TBC NTD REQUEST SFOC SAFETY CLEAR ALL 232 PERSONNEL FROM INSIDE OF AFT NTD *SCC FUSELAGE FOR HAZARDOUS ORB/ET OTC PURGE OPERATIONS. (*AAM) AFT *SCC *PSE ACCESS MONITOR WILL BE STATIONED NET AT AFT FUSELAGE ENTRANCE POST. 105 SAFETY WARNING SIGNS AT ENTRANCES OTC *AAM TO AFT FUSELAGE. REQUEST SFOC 132 SAFETY CONCURRENCE TO PROCEED. NOT PERFORMED ______ 14-0760 NTD ATTENTION ON PAD ___: PA ALL PERSONNEL CLEAR AFT FUSELAGE FOR PURGE ACTIVATION. NOT PERFORMED ______ 14-0761 *PSE *SCC AFT FUSELAGE CLEARED OF ALL PERSONNEL NET AND YOU HAVE SAFETY CONCURRENCE TO 105 ACTIVATE ORBITER/ET DISCONNECT CAVITY *SCC NTD PURGE PER G3251. 232 NTD TBC TBC CLHY 136 NOT PERFORMED ______ WARNING FOLLOWING OPERATION IS HAZARDOUS DUE TO ACTIVATION OF ORBITER/ET DISCONNECT CAVITY PURGE. 14-0762 CLHY TBC ORBITER/ET DISCONNECT CAVITY 136 PURGE WILL BE INITIATED AT TBC NTD THIS TIME PER OMI G3251. 232 NTD OTC 286 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0763 CECL OTC GSE COOLING RECONFIGURE FROM 132 CHILLED WATER TO REFER MODE COMPLETE. LAUNCH PAD TOURS ---------------- NOTE PERFORM NEXT TWO STEPS IF MVAK OPERATIONS ARE SCHEDULED AFTER PRSD LOAD OPERATONS. TOURS MAY BE PERMITTED ABOVE THE PAD SLOPE AT THE DISCRETION OF THE NTD. 14-0764 NTD OIC MVAK OPERATIONS READY TO COMMENCE. NET DISCONTINUE ALL TOURS ABOVE PAD SLOPE 110 FOR DURATION OF MVAK OPERATIONS. NTD 232 OTC MAY APPROVE EXCEPTIONS AS DIRECTED OTC *PAD BY LAUNCH DIRECTOR. 132 NOT PERFORMED ______ 14-0765 NTD OIC MVAK OPERATIONS COMPLETE. TOURS WITH NET PROPER AUTHORIZATION MAY NOW BE 110 PERMITTED ABOVE PAD SLOPE. 232 OTC OTC *PAD 132 NOT PERFORMED ______ 287 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORB/ET DISC CAVITY PURGE COMPLETE --------------------------------- NOTE DO NOT PERFORM NEXT THREE STEPS IF AFT FUSELAGE CLOSED OUT FOR FLIGHT OR NO AFT ACCESS REQUIRED. 14-0766 CLHY TBC ORBITER/ET DISCONNECT CAVITY 136 PURGE IS TERMINATED. READY TO OPEN AFT FUSELAGE. NOT PERFORMED ______ 14-0767 TBC NTD ORB/ET DISCONNECT CAVITY PURGE HAS 232 BEEN TERMINATED. READY TO OPEN AFT. NTD *SCC VERIFY O2 LEVEL ACCEPTABLE FOR OTC PERSONNEL ENTRY. REQUEST SAFETY *SCC *PSE CONCURRENCE TO OPEN AFT FUSELAGE FOR NET CONTROLLED WORK. REMOVE SAFETY 105 WARNING SIGNS. OTC *AAM NOT PERFORMED ______ 14-0768 *PSE *SCC O2 LEVEL IN AFT ACCEPTABLE. YOU NET HAVE SAFETY CONCURRENCE TO OPEN 105 AFT FUSELAGE FOR CONTROLLED WORK. *SCC NTD SAFETY WARNING SIGNS REMOVED. 232 NTD OTC NOT PERFORMED ______ NOTE HAZARDOUS STEPS DUE TO ORBITER/ET DISCONNECT CAVITY PURGE ARE COMPLETE. 288 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE/BORESIGHT XENON LIGHTS ------------------------------- WARNING WHEN XENON LIGHTS ARE OPERATING, PERSONNEL MUST AVOID LOOKING DIRECTLY INTO LIGHTS AS EYE DAMAGE MAY RESULT. NOTE DO NOT PERFORM NEXT TWO STEPS IF TANKING AND LAUNCH WILL BE DURING DAYLIGHT. 14-0769 -19H00M STM NTD ATTENTION ON PAD ___: SU72422 232 NTD XENON LIGHTS WILL BE TURNED ON. PA AVOID LOOKING INTO LIGHTS. EYE DAMAGE MAY RESULT. NOT PERFORMED ______ NOTE XENON FLOODLIGHTS WILL NOT BE TURNED ON DURING THE RSS MOVE FROM MATE POSITION UNTIL TRUCK 1 HAS BEEN SECURED IN THE PARK POSITION. 14-0770 STM JSTC TURN ON XENON LIGHTS AND SU72417 | 111 BORESITE. (1H30M) ELEC | ESSENTIAL PERSONNEL ------------------- SGS NASA --- ---- TECHS 7 ENGR 1 NOT PERFORMED ______ 289 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SSME FINAL PREPS ---------------- NOTE SSME PREPS INCLUDE LOADING SSME CONTROLLERS AND WILL REQUIRE MOUNTING TAPES ON TWO SPA TAPE DRIVES. (THE OPERATION CAN BE SUPPORTED WITH ONLY ONE DRIVE IF NECESSARY.) DUE TO MMU CONTENTION, DO NOT PERFORM SSME CONTROLLER LOADS UNTIL TFL LOADS AND IMU CHECK POINT DATA READS COMPLETE. 14-0771 -19H00M OTC CCME GO TO CH 146 AND PERFORM SSME SU72324 132 LPS FINAL PREPS PER OMI V9018.001 SU72326 JRPS AND OMI V9001VL4. (6 HR) MEC ACTIVATION -------------- NOTE DO NOT PERFORM NEXT FOUR STEPS IF MEC'S ARE POWERED UP. DO NOT PERFORM NEXT STEP DURING MAIN ENGINE CONTROLLER LOAD. 14-0772 -18H15M OTC CEPD PERFORM MEC POWER UP SU72312 132 PER OMI S9001VL1 ON CH 151. RT OMI LOG NO.__________ NOT PERFORMED ______ 14-0773 CEPD TERMINATE OPS CONCURRENCY IN WHICH MEC ACTIVATION WAS PERFORMED, OBTAIN SPA PRINTOUT AND ANALYZE PREFLITE BITE. VERIFY NO MEC FAILURES NOT PERFORMED ______ 290 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0774 OTC CEPD PERFORM MEC PREFLT BITE 132 EVALUATION. NOT PERFORMED ______ 14-0775 CEPD PERFORM CDS QLDB RETRIEVAL ON FD . VERIFY NO MEC FAILURES. NOT PERFORMED ______ 291 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ECLSS PLUG SET REMOVAL ---------------------- 14-0776 -18H00M OTC CECL PERFORM ORBITER OPERATION SU72332 132 SUPPORT SETUP 3 - ECLSS FES, NH3 AND O2/N2 PLUG SETS REMOVAL. ESSENTIAL PERSONNEL ------------------- ORB NASA --- ---- TECH 1 QUAL 1 1 OMRS V63AR0.025 14-0777 -18H00M OTC *PAD PERFORM ORBITER OPERATION SUPPORT SU72315| 132 SETUP 23 PART C - RCS PAPER COVER FINAL INSPECTION. (1 HOUR) 14-0778 JBPN STM GH2/GO2 SYSTEMS HAVE BEEN PNSA 111 MAINTAINED. INST/MADS/OEX RECORDER CONFIGURE FOR LCD | ---------------------------------------- | 14-0779 -17H30M OTC CISL PERFORM INST/MADS/OEX RCDR SU72313 | 132 CONFIGURE FOR LCD PER S0007VL4 232 NTD (SEQ 38). (1 HR) NTD JRPS OMRS S00FA0.540 OMRS S00FA0.670 14-0780 CCME OTC SSME LOADS COMPLETE. SPA TAPE SU72326 132 DRIVE NO LONGER REQUIRED. SU72328 OTC NTD PROCEEDING WITH SSME AVIONICS 232 CHECKS. NTD LPS 292 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE IN ORDER TO PROCEED WITH SSME FINAL PREPS, THE AFT MUST BE CLOSED OUT FOR FLIGHT AND MPS FUNCTIONAL CHECKS COMPLETE PER V9018.001 AND S1287. ORB LH2 FEED SYSTEM VENTING (REF V9018) --------------------------------------- NOTE DO NOT PERFORM NEXT FOUR STEPS IF RSS IS ROLLED BACK (PARK POSITION) AND LH2 TSM IS CLOSED OUT FOR FLIGHT. 14-0781 CMPS OTC LOUD HELIUM VENTING WILL OCCUR 132 FROM MPS LH2 RTLS DUMP PORT. OTC NTD REQUEST SAFETY NOTIFY PERSONNEL 232 WORKING IN LH2 TSM/T-0 CARRIER NTD *SCC PLATE LOUD VENTING WILL OCCUR *SCC *PSE MOMENTARILY. REQUEST SAFETY NET VERIFY NO PERSONNEL IN LINE OF 105 LH2 RTLS DUMP PORT EXIT, LOCATED NEAR 50-1 DOOR, AND NOTIFY ALL PERSONNEL IN VICINITY OF DUMP PORT THAT LOUD VENTING WILL OCCUR, REQUEST SAFETY REMAIN ON STATION UNTIL VENTING IS COMPLETE. NOT PERFORMED ______ 14-0782 CMPS OTC REQUEST PA ANNOUNCEMENT 132 OTC NTD ATTENTION ON PAD ___: 232 HELIUM WILL BE VENTED FROM MPS NTD RTLS DUMP PORT. FLOW WILL BE PA AUDIBLE. NOT PERFORMED ______ 293 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0783 *PSE *SCC PERSONNEL HAVE BEEN NOTIFIED AND NET NO LONGER IN VICINITY OF LH2 RTLS 105 DUMP PORT. YOU HAVE SAFETY *SCC NTD CONCURRENCE TO PROCEED. 232 NTD OTC OTC CMPS 132 NOT PERFORMED ______ 14-0784 CMPS OTC HELIUM VENTING FROM LH2 RTLS 132 DUMP PORT NEAR ORBITER 50-1 DOOR OTC NTD COMPLETE. SAFETY MAY BE RELEASED 232 AT THIS TIME. NTD *SCC *SCC *PSE NET 105 NOT PERFORMED ______ WWMS PREPS FOR SWITCHLIST ------------------------- 14-0785 OTC CFCP PERFORM WWMS PREPS FOR SWITCHLIST SU72311 132 PER S0007 VL4 (SEQ 54) ON CH 153. REPORT COMPLETION. 294 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0786 STM JBPN VERIFY FSS 3000 PSIG GN2 PNSA 111 PRESSURES WITHIN ACCEPTABLE LIMITS (3200-2800 PSIG). RECORD BELOW: 3000 PSIG PRIMARY__________PSIG 3200-2800 3000 PSIG SECONDARY__________PSIG 3200-2800 C1 CONSOLE LS IN FALLBACK AREA ------------------- 14-0787 -17H00M *SCB JSTC LIFE SUPPORT EQUIPMENT IN LS NET FALLBACK AREA (SLF MIDFIELD PARK SU72304 104 SITE) OPERATIONAL AND ALL JSTC STM COMMUNICATIONS FUNCTIONAL. 111 STM NTD 232 LH2 MLP MECHANICAL PREPS COMPLETE --------------------------------- 14-0788 CLHY TBC LH2 MLP MECHANICAL PREPARATIONS 136 FOR LOADING PER G3251 COMPLETE. TBC NTD 232 14-0789 -17H00M *PAD OTC ORBITER OPERATION SUPPORT 23 SU72315 | 132 PART C - RCS PAPER COVER FINAL INSPECTION COMPLETE. 295 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLEAR FOR OMS ENGINES COVER AND ------------------------------- THROAT PLUG REMOVALS -------------------- 14-0790 -17H00M OTC NTD REQUEST SFOC SAFETY CLEAR ALL SU72374 232 NONESSENTIAL PERSONNEL FROM A NTD *SCC 10 FT RADIUS OF THE OMS ENGINES. *SCC *PSE VERIFY ESSENTIAL PERSONNEL ARE NET PROPERLY ATTIRED IN HEAVY DUTY 105 RUBBER APRONS, FACESHIELDS AND HYPERGOLIC COMPATIBLE GAUNTLET GLOVES. PERFORM TOXIC VAPOR CHECKS DURING REMOVAL OF OMS ENGINE THROAT PLUGS AND COVERS. REQUEST SAFETY CONCURRENCE TO PROCEED. ESSENTIAL PERSONNEL ------------------- ORB NASA SFOC --- ---- ---- MECH TECH 3 QUALITY 1 1 ENGR 1 SAFETY 1 1 14-0791 NTD ATTENTION ON PAD ___: PA ALL NONESSENTIAL PERSONNEL CLEAR 10 FT RADIUS OF OMS ENGINES FOR OMS ENGINE COVER AND THROAT PLUG REMOVALS. 14-0792 TASK TEAM LEADER/REPRESENTATIVE PERFORM SAFETY INSPECTION OF THE LOCAL CONTROL AREA AND EGRESS ROUTE(S) FROM CONTROL AREA. VERIFY NO DISCREPANCIES WHICH AFFECT THE OPERATION AND/OR SAFE EGRESS FROM THE CONTROL AREA. TASK TEAM LEADER/ REPRESENTATIVE ____________________ DATE__________ 296 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0793 -17H00M *PSE *SCC NONESSENTIAL PERSONNEL CLEARED NET OF 10 FT RADIUS FROM OMS 105 ENGINES AND ESSENTIAL PERSONNEL *SCC NTD PROPERLY ATTIRED. YOU HAVE 232 SAFETY CONCURRENCE TO PROCEED NTD OTC WITH OMS ENGINE COVER AND THROAT PLUG REMOVALS. 14-0794 OTC *PAD BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE *PAD OMTO SEQUENCES OF APPENDIX Z. WARNING HAZARDOUS STEPS FOLLOW DUE TO POSSIBLE EXPOSURE TO N2O4 AND MMH. THROAT PLUG DESSICANT BAG MAY BE CONTAMINATED. SFOC SAFETY SHALL MONITOR OPERATIONS FOR TOXIC LEVELS, AND IF TLV IS EXCEEDED, EVACUATE PERSONNEL TO A SAFE AREA. REMOVE OMS ENGINE COVERS AND ---------------------------- THROAT PLUGS ------------ 14-0795 OTC NTD VERIFY HARDLINE BREATHING SUPPORT LS 232 AVAILABLE ON RSS 107 FT LEVEL FOR SU72354 NTD STM OME PLUG REMOVAL. STM JSTC 111 JSTC *SCB 14-0796 OTC *PAD PERFORM OPERATION SUPPORT SETUP SU72336 132 21 - OMS ENGINE COVERS AND THROAT PLUGS REMOVAL. (1 HR) 297 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORBITER HELIUM ANTI-ICE PURGE ----------------------------- VERIFICATION ------------ WARNING GN2 WILL FLOW THRU PURGE LINES IN AFT COMPARTMENT. NOTE DO NOT PERFORM NEXT THREE STEPS IF AFT CLOSED FOR FLIGHT. 14-0797 -17H00M CLOX TBC IF AFT NOT CLEARED, OBTAIN TIME 136 ESTIMATE AS TO WHEN AFT WILL BE TBC NTD CLEARED AND INFORM CLOX. 232 NTD OTC OTC *ACM 132 NOT PERFORMED ______ 14-0798 NTD *SCC VERIFY ORBITER AFT FUSELAGE 232 CLEARED OF ALL PERSONNEL. *SCC *PSE NET 105 NOT PERFORMED ______ 14-0799 *PSE *SCC AFT FUSELAGE CLEAR OF ALL NET PERSONNEL. 105 *SCC NTD 232 NTD TBC TBC CLOX 136 NOT PERFORMED ______ 298 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF THE LOX ANTI-ICE PURGE TEST IS REQUIRED. 14-0800 CLHY TBC G3251 ET OPERATION SUPPORT SETUP 6 - 136 CONFIGURATION FOR LOX ANTI-ICE PURGE TEST COMPLETE. NOT PERFORMED ______ ET NOSE CONE GN2 ANTI-ICE PURGE ------------------------------- SETUP ----- WARNING FOLLOWING STEPS ARE HAZARDOUS DUE TO ET NOSE CONE PURGE. NOTE DO NOT PERFORM NEXT THREE STEPS IF GOX VENT ARM IS RETRACTED. 14-0801 CLOX TBC REQUEST SFOC SAFETY CLEAR NOSE SU72310 136 CONE AREA OF ALL PERSONNEL. TBC NTD REQUEST SAFETY CONCURRENCE TO 232 PROCEED WITH NOSE CONE PURGE. NTD *SCC *SCC *PSE NET 105 NOT PERFORMED ______ 14-0802 -17H00M NTD ATTENTION ON PAD ___: PA ET NOSE CONE PURGE WILL BE INITIATED MOMENTARILY. LOUD GN2 FLOW WILL BE HEARD IN ET NOSE CONE AREA. NOT PERFORMED ______ 299 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0803 *PSE *SCC NOSE CONE AREA CLEAR OF ALL SU72296 NET PERSONNEL AND YOU HAVE SAFETY 105 CONCURRENCE TO PROCEED WITH *SCC NTD ET NOSE CONE PURGE. 232 NTD TBC TBC CLOX 136 NOT PERFORMED ______ OAA/HCU PREPS ------------- 14-0804 -17H00M OTC *PAD PERFORM HCU PER-OPERATION SETUPS SU72333 132 2 AND 3 PER OMI V2160. *PAD PHCU 14-0805 OTC *PAD PERFORM OAA PRE-OPERATION SETUP 132 2 PER OMI V2153. *PAD POAA GVA PREPS --------- 14-0806 TBC *PAD PERFORM GVA PRE-OPERATION SETUPS SU72343 136 2, 3, 4, 5 AND 6 PER OMI G2158. *PAD PME4 14-0807 CECL OTC ECLSS FES, NH3 AND 02/N2 PLUG SET 132 REMOVAL COMPLETE. OMRSD V63AR0.025 ET/IT PURGE READINESS TEST -------------------------- 14-0808 CLHY TBC VERIFY ET INTERTANK FLIGHT DOOR 136 INSTALLED AND INTERTANK ACCESS ARM RETRACTED. 14-0809 TBC CLHY CLEAR OF ALL PERSONNEL FROM 136 EL 207, RSS ACCESS TO RSS AUXILARY CLHY PLHY PLATFORM. POST SAFETY WARNING SIGNS. 166 300 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0810 PLHY CLHY ALL PERSONNEL CLEAR FROM EL 207, 166 RSS ACCESS TO RSS AUXILARY PLATFORM. CHLY TBC SAFETY WARNING SIGNS POSTED. TBC NTD 232 NTD *SCC 14-0811 CLHY TBC ET/IT GN2 PURGE WILL BE INITIATED 136 MOMENTARILY. 14-0812 TBC NTD ATTENTION ON PAD ___: 232 NTD ET INTERTANK PURGE WILL BE PA OPERATED INTERMITTENTLY FOR NEXT HOUR. RSS ET ACCESS PLATFORMS ----------------------- STOWED ------ NOTE PERFORM NEXT STEP IF NOT PREVIOUSLY ACCOMPLISHED BY SCHEDULE/OTHER DOCUMENT. 14-0813 QBSE STM RSS ET ACCESS PLATFORMS IN STSA | NET STOWED POSITION. SU72370 104 STM NTD 232 NOT PERFORMED ______ 14-0814 CCME OTC SSME AVIONICS CHECKS COMPLETE. SU72328 132 301 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS IF ESP NOT CLEARED. SSME 750 PNEUMATICS ACTIVATION ------------------------------ 14-0815 -16H25M CSME OTC IF NOT CLEARED, REQUEST SFOC SU72379 132 SAFETY CLEAR ALL PERSONNEL FROM OTC NTD ESP. ERECT WARNING SIGNS. 232 REQUEST SAFETY CONCURRENCE TO NTD *SCC PROCEED WITH SSME PNEUMATIC *SCC *PSE CHECKOUT. NET 105 NOT PERFORMED ______ 14-0816 NTD ATTENTION ON PAD ___: PA SSME HELIUM SYSTEM WILL BE PRESSURIZED AND SSME PURGES WILL BE ACTIVATED. NOT PERFORMED ______ 14-0817 *PSE *SCC ORBITER ESP CLEARED OF ALL NET PERSONNEL AND WARNING SIGNS 105 INSTALLED. YOU HAVE SAFETY *SCC NTD CONCURRENCE TO PROCEED WITH 232 SSME PNEUMATIC CHECKOUT. NOT PERFORMED ______ 14-0818 NTD OTC PERFORM SSME 750 PNEUMATICS 232 ACTIVATION PER OMI V9018.001. OTC CSME (AFT FUSELAGE CLOSED FOR FLIGHT) 132 SSME PNEUMATIC CHECKOUT ----------------------- 14-0819 -16H20M NTD OTC PERFORM SSME PNEUMATIC CHECKOUT SU72329 232 LPS PER OMI V9018.001. REQUEST LPS OTC CMPS SUPPORT CSME ON OIS CH 146. 132 (ESP CLEARED AND AFT FUSELAGE CLOSED FOR FLIGHT) (30 MIN) 14-0820 LPS C2MC PLACE PP1 UNITS 2 THRU 5 ON LINE 127 FOR CMPS. 302 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT TWO STEPS IF GOX VENT ARM IS RETRACTED. 14-0821 CLOX TBC ET NOSE PURGE FLOW COMPLETE. 136 REQUEST SAFETY OPEN GOX VENT TBC NTD ARM FOR CONTROLLED WORK. 232 NTD *SCC *SCC *PSE NET 105 NOT PERFORMED ______ 14-0822 *PSE *SCC GOX VENT ARM OPEN FOR CONTROLLED WORK. NET 105 *SCC NTD 232 NTD TBC TBC CLOX 136 NOT PERFORMED ______ NOTE HAZARDOUS STEPS COMPLETE. 303 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB HPU EXHAUST DUCT PLUGS AND ------------------------------ OVERBOARD DRAIN LINE SCRUBBER REMOVALS -------------------------------------- 14-0823 CBHY TBC SRB AFT SKIRT GN2 PURGE VERIFIED 136 NOT ACTIVE. TBC NTD 232 NTD *SCC *SCC *PSE NET 105 14-0824 BHT_ TBC REQUEST SFOC SAFETY CLEAR SU72381 136 NONESSENIAL PERSONNEL ON MLP TBC NTD ZERO LEVEL 10 FT RADIUS 232 AROUND EACH OF THE SRB TURBINE NTD *SCC EXHAUST DUCTS FOR PLUG REMOVAL. *SCC *PSE VERIFY PERSONNEL PROPERLY ATTIRED NET IN FACESHIELDS, RUBBER APRONS AND HYPER COMPATIBLE GLOVES AND CONCURRENCE TO PROCEED. ESSENTIAL PERSONNEL ------------------- SFOC ---- SRB MECH TECHS 2 QC 1 SAFETY 1 ENGR 1 304 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0825 NTD ATTENTION ON PAD ___: PA ALL NONESSENTIAL PERSONNEL CLEAR 10 FOOT RADIUS OF SRB HPU EXHAUST DUCTS FOR SRB EXHAUST PLUG AND OVERBOARD DRAIN LINE SCRUBBER REMOVAL. 14-0826 *PAD TTL TASK TEAM LEADER/REPRESENTATIVE PERFORM SAFETY INSPECTION OF THE LOCAL CONTROL AREA AND EGRESS ROUTE(S) FROM CONTROL AREA. VERIFY NO DISCREPANCIES WHICH AFFECT THE OPERATION AND/OR SAFE EGRESS FROM THE CONTROL AREA. TASK TEAM LEADER/ REPRESENTATIVE ____________________ DATE __________ 14-0827 *PSE *SCC CONTROL AREA CLEAR ON MLP ZERO NET LEVEL AROUND SRB HPU TURBINE 105 EXHAUST DUCTS. SAFETY VERIFIES *SCC NTD PERSONNEL PROPERLY ATTIRED AND 232 CONCURRENCE TO PROCEED WITH SRB NTD TBC HPU EXHAUST DUCT PLUGS AND TBC BHT_ OVERBOARD DRAIN LINE SCRUBBER 136 REMOVAL. 14-0828 TBC BHT_ BRIEF PERSONNEL ON HAZARDS THAT WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. 305 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING HAZARDOUS OPERATION - SRB HPU EXHAUST PLUG AND OVERBOARD DRAIN LINE SCRUBBER REMOVAL FOLLOWS, DUE TO WORK AT UNPROTECTED EDGE OF SRB FLAME HOLES AND POSSIBLE EXPOSURE TO HYDRAZINE VAPORS. FACESHIELDS, RUBBER APRONS AND HYPERCOMPATIBLE GLOVES REQUIRED. SAFETY HARNESS WITH SECURED LANYARD REQUIRED FOR TECHNICIAN(S) REMOVING PLUGS. SFOC SAFETY SHALL MONITOR BREATHING ZONE FOR N2H4 TOXIC LEVELS. IF TLV IS EXCEEDED, EVACUATE PERSONNEL TO OUTSIDE BREATHING ZONE AND ONLY REENTER AFTER TLV IS DETERMINED TO BE SATISFACTORY. DO NOT STAND DIRECTLY BEHIND PLUGS DURING REMOVALS. 14-0829 BHT_ PERFORM FOLLOWING: SU72341 1. REMOVE TURBINE EXHAUST DUCT PLUG AND OVERBOARD DRAIN LINE SCRUBBERS AND TUBING FROM ALL FOUR SRB HPU TURBINE EXHAUST DUCTS AND OVERBOARD DRAIN LINES. LEFT SRB TILT TIR NO.__________ T:______ SS1 LEFT SRB ROCK TIR NO.__________ T:______ SS1 RIGHT SRB TILT TIR NO.__________ T:______ SS1 306 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0829 RIGHT SRB ROCK CON'T TIR NO.__________ T:______ SS1 2. RINSE EXHAUST DUCT PLUGS AND OVERBOARD DRAIN LINE SCRUBBERS AND TUBING WITH WATER UNTIL SFOC SAFETY VERIFIES TOXIC VAPOR CHECKS LESS THAN 0.1 PPM HYDRAZINE. T:______ SS2 3. DOUBLE BAG EXHAUST DUCT PLUGS AND OVERBOARD DRAIN LINE SCRUBBERS AND TUBING INTO ZIPLOCK BAG WITH TAPE. T:______ SS3 4. PREPARE TWO DECON TAGS (KSC FORM 4-295) AND ATTACH TO BAG(S) AS FOLLOWS, ONE INSIDE WITH COMPONENTS AND ONE OUTSIDE, (TOTAL OF FOUR DECON TAGS REQUIRED) RETURN TO STORAGE. T:______ SS4 14-0830 BHT_ TBC SRB HPU TURBINE EXHAUST DUCT 136 PLUGS AND OVERBOARD DRAIN LINE TBC NTD SCRUBBERS REMOVAL COMPLETE. 232 REQUEST SFOC SAFETY PERFORM O2 NTD *SCC LEVEL CHECK AND TOXIC VAPOR *SCC *PSE CHECK OF SRB HPU TURBINE NET EXHAUST DUCTS. REQUEST SFOC 105 SAFETY CONCURRENCE TO OPEN AREA AROUND SRB HPU TURBINE EXHAUST DUCTS. 307 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0831 *PSE *SCC SAFETY VERIFIES O2 ATMOSPHERE SU72381 NET CHECKS AND TOXIC VAPOR CHECKS OF 105 SRB HPU TURBINE EXHAUST DUCTS *SCC NTD VICINITY. YOU HAVE SAFETY 232 CONCURRENCE TO OPEN SRB HPU EXHAUST NTD TBC DUCT CONTROL AREA FOR CONTROLLED WORK. NOTE HAZARDOUS STEPS DUE TO SRB HPU EXHAUST DUCT PLUGS AND OVERBOARD DRAIN SCRUBBERS REMOVAL COMPLETE. NEXT STEP NOT A CONSTRAINT TO RSS ROTATION. SRB TIR LOG ----------- 14-0832 TBC CMQC VERIFY ALL SRB TIR LOG ITEMS SU72340 136 CLOSED. CMQC PQCG TQV:____ 308 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SAFETY SHOWER REMOVAL --------------------- 14-0833 STM NTD REQUEST SAFETY CONCURRENCE TO 232 REMOVE SAFETY SHOWERS FROM MLP. NTD *SCC *SCC *PSE NET 105 14-0834 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO NET REMOVE SAFETY SHOWERS FROM MLP. 105 *SCC NTD 232 NTD STM 14-0835 STM JBDY PROVIDE TRUCKS AND MOBILE CRANE HESA 111 FOR REMOVAL OF SAFETY SHOWERS SU72353 JBDY GBHE AND LOOSE EQUIPMENT FROM MLP 104 (Q3205). REPORT COMPLETION. 14-0836 STM JBFX REMOVE SAFETY SHOWERS AND WSSA 111 JBDY EYEWASH FOUNTAINS FROM HESA EAST PAD SURFACE AND MLP SU72363 PER OMI M3190. (4 HRS) 309 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE UCOM/GSS TECHS MEET AT BASE OF FSS ELEVATOR. DO NOT PERFORM NEXT THREE STEPS IF EQUIPMENT NOT INSTALLED. 14-0837 -16H00M TBC NTD SRB PERSONNEL READY FOR OIS UNIT COMM 232 REMOVAL. UCOM REMOVE TWO PNSA NTD STM PORTABLE OIS UNITS OUTBOARD OF SRB STM GYCC FLAME HOLES ON MLP ZERO LEVEL. 111 JBPN INSTALL CAPS ON GOOSENECK CABLE GYCC JYCD CONNECTORS. (10 MIN) GSS REMOVE 117 PURGE FLEXHOSES. UCOM T:______ GSS T:______ NOT PERFORMED ______ 14-0838 JYCD GYCC TWO PORTABLE OIS UNITS ON COMM 117 MLP ZERO LEVEL, OUTBOARD OF SRB GYCC STM FLAME HOLES, HAVE BEEN REMOVED. 111 CAPS INSTALLED ON GOOSENECK CABLE STM NTD CONNECTORS. 232 NOT PERFORMED ______ 14-0839 JBPN STM PURGE FLEXHOSE DISCONNECTED PNSA 111 FOR REMOVAL OF TWO OIS BOXES ON MLP. NOT PERFORMED ______ 310 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0840 CLHY TBC ET/IT PURGE READINESS TEST 136 COMPLETE. NOTIFY CLHY IF INTERTANK ENTRY REQUIRED SO INTERTANK PURGE CAN BE SECURED. 14-0841 CLHY TBC ET INTERTANK PURGE OPERATIONS COMPLETE. 136 WARNING SIGNS REMOVED AND AREA OPEN TBC NTD FOR NORMAL OPERATIONS ON RSS AUXILARY 232 PLATFORM. NTD *SCC 311 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 FSS MECHANICAL PREPS COMPLETE --------------------------------- 14-0842 CLHY TBC FSS MECHANICAL PREPARATIONS FOR 136 LOADING PER G3251 COMPLETE. OI AND MADS/OEX RCDR CONFIGURE COMPLETE --------------------------------------- 14-0843 -16H00M CISL OTC OI AND MADS/OEX RCDR SETUPS FOR SU72313 132 TERMINAL COUNT COMPLETE. OMRSD V78GA0.020 OMRSD V75AP0.020 NOTE PERFORM NEXT TWO STEPS FOR OV-103. PERFORM NEXT TWO STEPS AFTER COMPLETION OF MADS RECORDER CONFIGURATION FOR LAUNCH. 14-0844 OTC CEPD PERFORM MEC PREFLT BITE EVALUATION. 132 NOT PERFORMED ______ 14-0845 CEPD PERFORM CDS QLDB RETRIEVAL ON FD VERIFY NO MEC FAILURES NOT PERFORMED ______ OAA/HCU PREPS COMPLETE ---------------------- 14-0846 POAA *PAD OAA/HCU PREPS PER PRE-OPERATION SU72333 *PAD OTC SETUP 2 OF V2153 AND PRE-OPERATION 132 SETUPS 2 AND 3 OF V2160 COMPLETE. GVA PREPS COMPLETE ------------------ 14-0847 PME4 *PAD GVA PREPS PER PRE-OPERATION SU72343 *PAD TBC SETUPS 2, 3, 4, 5 AND 6 OF 136 G2158 COMPLETE. TBC NTD 232 312 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MICROBIAL SAMPLE/CREW MODULE ---------------------------- NOTE MATERIALS/EQUIPMENT TO BE SUPPLIED BY KRUG/JSC REPS. SAMPLING PROCEDURES TO BE SUPERVISED AND PERFORMED BY KRUG/JSC REPS. 14-0848 -16H00M OTC *PAD PERFORM F-0 TO F-2 MICROBIAL SU72282 132 SAMPLING INSIDE CREW MODULE USING JSC MICROBIAL SAMPLING PROCEDURES, JSC-18633 AS GUIDE. ATTACH COPY OF SAMPLING LOCATIONS(S) FROM PROCEDURES. (2 HR) OMS ENGINE COVERS AND THROAT PLUG --------------------------------- REMOVALS COMPLETE ----------------- 14-0849 -16H00M *PAD OTC OMS ENGINE COVERS AND THROAT 132 PLUGS REMOVED. REQUEST SFOC OTC NTD SAFETY PERFORM TOXIC VAPOR CHECKS 232 AND VERIFY TOXIC VAPOR LEVELS NTD *SCC ACCEPTABLE. REQUEST SAFETY *SCC *PSE CONCURRENCE TO OPEN (OMS ENGINE) NET CONTROL AREA FOR CONTROLLED WORK. 105 PROVIDE TVC READINGS FOR OME THROAT PLUGS. 14-0850 *PSE *SCC TOXIC VAPOR CHECKS ACCEPTABLE. SU72374 NET YOU HAVE SAFETY CONCURRENCE TO 105 OPEN OMS ENGINE CONTROL AREA FOR *SCC NTD CONTROLLED WORK. TVC READINGS 232 FOR THROAT PLUGS ARE AS FOLLOWS: NTD OTC OTC *PAD LOME PLUG __________ PPM N2O4 BD 132 __________ PPM MMH BD ROME PLUG __________ PPM N2O4 BD __________ PPM MMH BD 313 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0851 *PAD OTC OPERATION SUPPORT SETUP 21 - OMS SU72336 132 ENGINE COVERS AND THROAT PLUG OTC NTD REMOVAL COMPLETE. 232 14-0852 OTC NTD HARDLINE BREATHING SUPPORT NO SU72354 232 LONGER REQUIRED ON RSS 107 FT NTD STM LEVEL. STM JSTC 111 JSTC *SCB 114 NOTE HAZARDOUS STEPS FOR OMS ENGINE COVER AND THROAT PLUG REMOVALS COMPLETE. 14-0853 OTC *PAD REMOVE PIC BOARDS AND RETRACT HESD 132 107 FT LEVEL DIVING BOARDS PER SU72362 232 NTD OMI V3529. (2 HRS) (SPIDER 50) NTD STM STM JBDY 111 JBDY SPIDER NET 50 105 14-0854 OTC *PAD VERIFY ORBITER ESP CONFIGURED FOR 132 LOWERING. ACTIVATE HCU ------------ 14-0855 -16H00M OTC CGSS ACTIVATE HCU AND PRESSURIZE FSS SU72334 132 HYDRAULIC SYSTEM PER OMI V2160. SSME PNEUMATIC CHECKOUT COMPLETE -------------------------------- 14-0856 -15H40M CSME OTC SSME PNEUMATIC CHECKOUT COMPLETE. SU72329 132 PROCEEDING WITH SSME GSE SETUPS. SU72330 OTC NTD MAINTAIN CONTROLS ON ESP FOR 232 GN2 FLOW. NTD *SCC 314 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- INSTRUMENTATION MEASUREMENT SUPPORT ----------------------------------- NOTE DO NOT PERFORM NEXT STEP IF ACCOMPLISHED PRIOR TO CALL TO STATIONS. 14-0857 -15H30M STM JCFM PROCEED TO PAD MLP. PERFORM SU72356 111 FOLLOWING: 1. REMOVE MLP RAIN GAGE FROM ZERO LEVEL OF MLP. 2. REMOVE LCD AND CPT FROM NORTH SITE CWLIS. NOT PERFORMED ______ GND SUPPORT COMM SYS VALID (A2700) ---------------------------------- 14-0858 NTD *MIL VERIFY MILA READY TO SUPPORT SU72368 232 S0007. 14-0859 STM GYCC PERFORM VALIDATION OF MULTI-BURST COMM 111 *MIL VIDEO TEST SIGNAL PER OMI A2700. GYCC GYVW (1 HR) PTP 14-0860 NTD *MIL PERFORM LPS/MILA CIRCUIT 232 STM VALIDATION PER OMI A2700. LPS (1 HR) JRPS 14-0861 LPS VERIFY LPS TO MSFC KMTS DATA LINK. 14-0862 LPS VERIFY DOWNEY RECEIVING CCP AND | PCMMU DATA. | 14-0863 LPS VERIFY ODRC RECEIVING PCMMU DATA. | 315 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FD MS SEAT/EQUIP INSTL ---------------------- 14-0864 -15H30M OTC *PAD PERFORM FD MS SEAT AND EQUIPMENT SU72337 132 INSTALLATION PER FCS TPS ________. NOTE PERFORM NEXT STEP FOR MISSIONS THAT DO NOT REQUIRE LATE ACCESS TO THE SPACELAB OF SPACEHAB USING MVAK. FD/MD SEAT CABLE ROUTING ------------------------ 14-0865 OTC *PAD PERFORM FD/MD MS SEAT CABLE 132 ROUTING PER FCS TPS _________. NOT PERFORMED ______ NOTE HVAC ENGR WILL DETERMINE IF NEXT STEP REQUIRED. 14-0866 -15H15M STM JBAC CONFIGURE PAD-___ PTCR HVAC HVAA 111 SYSTEM WATER CHILLER(S) WITH WC-1 AND/OR WC-2 ON LINE AND OPERATING DEPENDING ON SYSTEM LOAD, WITH WC-3 IN STANDBY, PER HVAC SUPERVISION/ ENGINEERING DIRECTION AND PER OMI M3006 PAD A/OMI M3023 PAD B. NOT PERFORMED ______ 316 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT STEP IF SYSTEMS HAVE REMAINED CONFIGURED FROM PREVIOUS RUN OF S0007. SAFETY SHOWER/EYEWASH REMOVAL COMPLETE -------------------------------------- 14-0867 -15H00M JBFX STM SAFETY SHOWERS AND EYEWASH WSSA 111 FOUNTAINS REMOVAL COMPLETE. SU72363 NOT PERFORMED ______ FCMS POWER UP AND DATA RECORDING -------------------------------- 14-0868 OTC CFCP PERFORM FUEL CELL MEASUREMENT SU72433 132 JRPS SYSTEM (FCMS) POWER UP AND DATA JSDC RECORDING (OPTION A) PER S9001VL2 | (SEQ 93) ON OIS CH 153. REPORT | COMPLETION. (15 MIN) FUEL CELL CABIN PREPS --------------------- NOTE MASTER ALARMS WILL OCCUR IN NEXT STEP (ADVISE CISL). MASTER ALARMS WILL BE RESET PER V1040.002. 14-0869 -15H00M OTC CFCP PERFORM REMOTE FUEL CELL SU72462 132 CECL ACTIVATION CABIN PREPS PER OMI V1040.002 ON OIS CH 153. 317 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OAA PREPS --------- 14-0870 -15H00M CGSS OTC FSS HYDRAULIC SYSTEM PRESSURIZED SU72334 132 PER V2160. 14-0871 OTC CGSS PERFORM OAA PREPS PER OMI V2153. SU72335 132 14-0872 *PAD OTC ORBITER PRE-OPERATION SETUP 132 9 - LAUNCH ACCESSORIES SYS PREPS COMPLETE. NOTE FES DUCT REMOVAL (T-17H) MUST BE COMPLETED PRIOR TO TRIPLE FLIP RETRACTION. NEXT TWO STEPS MUST BE COMPLETE PRIOR TO START OF TSM FINAL PREPS FOR EACH RESPECTIVE TRIPLE FLIP. 14-0873 OTC NTD ACCESS NO LONGER REQUIRED, STSA | 232 RETRACT RSS TRIPLE FLIPS PER SU72359 NTD STM OMI M3094. STM QBSE NET 104 14-0874 QBSE STM RSS TRIPLE FLIP PLATFORM STSA | NET RETRACTIONS COMPLETE. SU72359 104 STM NTD 232 NTD OTC *SCC 318 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TSM PRE-ARM PREPS ------------------ WARNING DO NOT PERFORM LOX AND LH2 TSM FINAL PREPS UNTIL TRIPLE FLIPS RETRACTED TO PRECLUDE DAMAGE TO T-0 CARRIER PLATE; ALSO PRYO'S ARE INSTALLED. 14-0875 OTC NTD OBTAIN FIXED O2 READINGS OF LO2 PWRA | 232 AND LH2 TSM'S FOR PERSONNEL SU72316 NTD STM ENTRY REQUEST SAFETY CONCURRENCE STM JBEP FOR PERSONNEL ENTRY TO LO2 AND LH2 111 TSM'S. JBEP STM STM NTD 232 NTD *SCC *SCC *PSE NET 105 14-0876 OTC NTD WITH PORTABLE METER, ESTABLISH NTD *SCC A GH2 BASELINE READING (LEL SCALE) 232 OUTSIDE LH2 TSM. VERIFY NO INCREASE *SCC *PSE OF GH2 ABOVE BASELINE INSIDE LH2 NET TSM. 105 14-0877 *PSE *SCC O2 AND H2 READINGS ACCEPTABLE. NET YOU HAVE CONCURRENCE FOR PERSONNEL 105 ENTRY TO LO2 AND LH2 TSM'S. *SCC NTD 232 NTD OTC 14-0878 OTC *PAD PERFORM LH2 TSM PRE-ARMING PREPS 132 QHSM PER OMI V3517. 14-0879 OTC *PAD PERFORM LOX TSM PRE-ARMING PREPS 132 QOSM PER OMI V3518. 319 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VERIFY FREQ CLEARANCE --------------------- 14-0880 -15H00M OTC NTD VERIFY PROTECTED OPEN LOOP SU72352 232 FREQENCY CLEARANCE FOR S-BAND NTD STM AND UHF THRU NEGATIVE AOA. STM ENDO (ENDO 853-2436/5941) 111 1. S-BAND PM S-BAND FM UHF 2041.9 MHZ 259.7 MHZ 2106.4 MHZ 2250.0 MHZ 296.8 MHZ 2217.5 MHZ 2287.5 MHZ FREQUENCY CLEARANCE NO.__________ 2. UHF GUARD 243 MHZ FROM ______HRS THRU ______HRS ______DATE. FREQUENCY CLEARANCE NO.__________ GND SUPPORT COMM SYS VALID COMPLETE ----------------------------------- 14-0881 *MIL STM MULTI BURST VIDEO TEST SIGNAL COMM GYCC VALIDATION PER A2700 COMPLETE. SU72368 111 STM NTD 232 14-0882 STM NTD LPS/MILA CIRCUIT VALIDATION 232 PER A2700 COMPLETE. 320 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SSME GN2 PURGE CHECKOUT ----------------------- 14-0883 -14H30M CSME OTC SSME GSE SETUPS COMPLETE, SU72330 132 REQUEST PERMISSION TO PROCEED OTC NTD WITH SSME GN2 PURGE CHECKOUT 232 PER V9018.001. NOTE DO NOT PERFORM NEXT THREE STEPS IF ESP ALREADY CLEARED. 14-0884 NTD *SCC VERIFY ALL PERSONNEL CLEARED 232 FROM ORBITER ESP AND WARNING *SCC *PSE SIGNS ERECTED. REQUEST SAFETY NET CONCURRENCE TO PROCEED. 105 NOT PERFORMED ______ 14-0885 NTD ATTENTION ON PAD ___: PA ALL PERSONNEL CLEAR ORBITER ESP. SSME GN2 PURGE WILL BE ACTIVATED. NOT PERFORMED ______ 14-0886 *PSE *SCC ORBITER ESP CLEARED OF ALL PERSONNEL. NET WARNING SIGNS HAVE BEEN INSTALLED. 105 YOU HAVE SAFETY CONCURRENCE TO *SCC NTD PROCEED WITH SSME GN2 PURGE CHECKOUT. 232 NOT PERFORMED ______ 321 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING HAZARDOUS OPERATION - SSME GN2 PURGE CHECKOUT FOLLOWS, (HAZ DUE TO PRESENCE OF GN2). 14-0887 -14H30M NTD OTC PROCEED WITH SSME GN2 PURGE SU72331 232 CHECKOUT PER OMI V9018.001. OTC CSME (30 MIN) 132 FUEL CELL ACTIVATION PREPS COMPLETE ----------------------------------- 14-0888 -14H30M CFCP OTC REMOTE FUEL CELL ACTIVATION SU72462 CECL CABIN PREPS COMPLETE (V1040.002). 132 REQUEST CISL PERFORM C&W MEMORY OTC CISL READ AND CLEAR. 14-0889 CISL MS1 PANEL R13U SU72467 CAUTION/WARNING MEMORY SW - READ (HOLD) REPORT MATRIX LIGHTS ON: RECORD IN S0007VL4 APPENDIX P-5 VERIFY FOLLOWING MATRIX LIGHTS ON: 062 072 082 092 102 112 OMRS V45CG0.040-A OMRS V45CG0.040-B OMRS V45CG0.040-C 322 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0890 CISL MS1 PANEL R13U CAUTION/WARNING MEMORY SW - CLEAR AND RELEASE MEMORY SW - READ HOLD REPORT MATRIX LIGHTS ON: RECORD IN S0007VL4 APPENDIX P-4 VERIFY FOLLOWING MATRIX LIGHTS ON: 062 072 082 092 102 112 OMRS V45CG0.040-A OMRS V45CG0.040-B OMRS V45CG0.040-C 14-0891 CISL MS1 PANEL R13U CAUTION/WARNING MEMORY SW - RELEASE SSME GN2 PURGE C/O - COMPLETE ----------------------------- 14-0892 -14H00M CSME OTC SSME GN2 PURGE CHECKOUT COMPLETE. 132 (V9018.001). PRINTER PLOTTERS NO OTC LPS LONGER REQUIRED. PLACE PP 1 UNITS LPS C2MC 2 THRU 5 OFFLINE AND REMOVE DATA 127 FOR DATA COORDINATOR PICKUP. 323 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0893 CSME OTC SSME FINAL PREPS PER V9018.001 132 COMPLETE. OTC NTD 232 OMRSD S00FA0.213-A-1 OMRSD S00FA0.213-B-1 OMRSD S00FA0.213-C-1 OMRSD S00FA0.213-D-1 OMRSD S00FA0.213-E-1 OMRSD S00FA0.213-F-1 OMRSD S00FA0.213-G-1 OMRSD S00FA0.213-H-1 OMRSD S00FA0.213-I-1 OMRSD S00FA0.213-J-1 NOTE HAZARDOUS OPERATION (SSME GN2 PURGE) COMPLETE. PERFORM NEXT TWO STEPS IF ESP/ECP AREA IS REQUIRED TO BE OPENED. 14-0894 NTD *SCC SSME GN2 PURGE CHECKOUT COMPLETE. SU72331 232 VERIFY O2 LEVELS ACCEPTABLE ON *SCC *PSE ORBITER ESP/ECP. REQUEST SAFETY NET CONCURRENCE TO OPEN ORBITER 105 ESP/ECP AREA FOR CONTROLLED WORK AND TO REMOVE SIGNS. NOT PERFORMED ______ 14-0895 *PSE *SCC O2 LEVELS ARE ACCEPTABLE ON SU72379 NET ORBITER ESP/ECP. YOU HAVE SAFETY 105 CONCURRENCE TO OPEN ORBITER ESP/ECP *SCC NTD AREA FOR CONTROLLED WORK. 232 SIGNS HAVE BEEN REMOVED. NOT PERFORMED ______ 14-0896 NTD STM SPECIAL POWER TECHS (1-0702) PWRA | 232 REMOVE ODMS REMOTE DIGITAL SU72355 | STM JBEP DISPLAYS AT MLP LH2 AND LO2 | 111 TSMS PER OMI M3088. COVERALLS REQUIRED. REPORT COMPLETION. 324 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF PAYLOAD ESA MONITOR CONSOLES REQUIRED EARLY. 14-0897 NTD LPS PERFORM SUPPORT OPERATION SU72406 232 SUPPORT SETUP 4 - LCC2 PAYLOAD SUPPORT CONFIGURATION. (CONSOLES TO BE ON LINE BY T-11H AND HOLDING) NOT PERFORMED ______ 14-0898 *PAD OTC ORBITER OPERATION SUPPORT SETUP SU72314 132 2 - ORBITER STRUCTURAL PANEL CONFIGURATION FOR TANKING AND LAUNCH, PART B, COMPLETE. MICROBIAL SAMPLE/CREW MODULE - COMPLETE --------------------------------------- 14-0899 -14H00M *PAD OTC CREW MODULE MICROBIAL SAMPLING 132 (L-2 TO L-0 DAYS) COMPLETE. JSC REP____________________ OMRSD V67AA0.030-B OAA PREPS COMPLETE ------------------ 14-0900 -13H00M CGSS OTC OAA PREPS PER V2153 COMPLETE. SU72335 132 CONSOLE CLOSED OUT. 325 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GOX VENT ARM PREPS ------------------ 14-0901 -13H00M NTD TBC PERFORM GOX VENT ARM SYSTEM SU72348 232 INITIAL PREPS PER OMI G2158. TBC CMEC 136 NOTE PERFORM GOX VENT HOOD IRONOUT (CONTINGENCY) IF A NEW SEAL HAS BEEN INSTALLED BUT NOT IRONED OUT. GOX VENT HOOD SEAL IRONOUT -------------------------- (CONTINGENCY) ------------- NOT PERFORMED ______ 14-0902 TBC NTD PERFORM M3703 PREPS TO SUPPORT JSTC 232 ET GOX VENT HOOD GN2 PURGE PNU NTD STM PREPS (G2158). (30 MIN). GSPN STM JSTC COORDINATE WITH CMEC, CH 186. 111 JSTC GSPN 114 14-0903 STM JBPN VERIFY LPGN2 VALVE A135935 OPEN. PNSA 111 T:______| 14-0904 JSTC STM M3703 PREPS TO SUPPORT ET GOX | 111 VENT HOOD GN2 PURGE PREPS | STM NTD (G2158) COMPLETE. | 232 | NTD TBC | 14-0905 CMEC TBC READY TO PROCEED WITH GOX VENT 136 ARM GN2 PURGE OPERATION. REQUEST TBC NTD CONCURRENCE TO CLEAR. 232 NTD *SCC 326 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0906 CMEC PMEA FSS 255 FT LEVEL SU72377 1. CLEAR GOX VENT ARM OF NONESSENTIAL PERSONNEL. ESSENTIAL PERSONNEL ARE AS FOLLOWS: PME4, PAD MECH TECH PQC1, PAD QC 2. REQUEST SAFETY CONCURRENCE TO INITIATE GN2 PURGE TO GOX VENT HOOD. 14-0907 CMEC TBC REQUEST FOLLOWING PA ANNOUNCEMENT: 136 TBC NTD ATTENTION AT PAD___: 232 NTD GOX VENT ARM HEATED PURGE WILL BE PA ACTIVATED MOMENTARILY. NONESSENTIAL PERSONNEL CLEAR GOX VENT ARM. 14-0908 CMEA CMEC NONESSENTIAL PERSONNEL CLEAR OF GOX CMEC TBC VENT ARM. REQUEST SAFETY CONCURRENCE 136 TO BEGIN GN2 FLOW. TBC NTD 232 NTD *SCC 14-0909 *SCC NTD YOU HAVE SAFETY CONCURRENCE TO 232 PROCEED WITH GN2 FLOW TO GOX NTD TBC VENT ARM. TBC CMEC 136 14-0910 TBC CMEC BRIEF PERSONNEL ON HAZARDS THAT WILL 136 BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. 327 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE HAZARDOUS GN2 OPERATIONS COMPLETE. 14-0911 TBC NTD HAZARDOUS GN2 OPERATIONS COMPLETE. 232 REQUEST SAFETY CONCURRENCE TO OPEN NTD *SCC GOX VENT ARM FOR CONTROLLED WORK. *SCC *PSE NET 105 14-0912 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO OPEN NET GOX VENT ARM FOR CONTROLLED WORK. 105 *SCC NTD 232 NTD TBC 14-0913 CMEC TBC GOX VENT HOOD SEAL IRONOUT COMPLETE. 136 GOX VENT HOOD SEAL IRONOUT -------------------------- (CONTINGENCY) COMPLETE ---------------------- CONFIGURE ELECTRICAL EQUIP -------------------------- 14-0914 STM JSTC VERIFY POWER AT TEL IV AND ELEC 111 RADAR 19:14. (FPQ-14) SU72365 JSTC JSEP 114 14-0915 STM JBAC VERIFY FOLLOWING LISTED BUILDINGS HVAC 111 SYSTEMS OPERATIONAL: N6-1118 SOUTH REPEATER STATION M7-531 BANANA RIVER REPEATER STATION K7-442 DLTR #2 K7-89 DLTR #3 J8-2204 DLTR #4 (PAD-A) J7-1736 DLTR #5 (PAD-B) J7-986 DLTR #6 (PAD-B) M6-138 CD&SC K6-1193 VABR 328 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TSM PRE-ARMING PREPS - COMPLETE ------------------------------- 14-0916 -13H00M QOSM OTC LOX TSM PRE-ARMING PREPS PER 132 V3518 COMPLETE. 14-0917 QHSM OTC LH2 TSM PRE-ARMING PREPS PER 132 V3517 COMPLETE. 14-0918 OTC NTD LOX AND LH2 TSM PRE-ARMING PREPS SU72316 232 COMPLETE. NOTE NEXT STEP TO BE PERFORMED DURING DAYLIGHT HOURS AS CLOSE TO FINAL RSS RETRACTION AS POSSIBLE. T6446 (SEQ 02) MUST BE COMPLETED PRIOR TO +Y/-Y OWP RETRACTION. 14-0919 TBC *PAD PERFORM ET PRE-PROPELLANT LOAD SU72346 136 INSPECTION PER OMI T6446. OMRS T09QAL.030-1 329 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TSM FINAL PREPS ---------------- WARNING DO NOT PERFORM LOX AND LH2 TSM FINAL PREPS UNTIL TRIPLE FLIPS RETRACTED TO PRECLUDE DAMAGE TO T-0 CARRIER PLATE; ALSO PRYO'S ARE INSTALLED. 14-0920 -13H00M QOSM OTC READY TO PROCEED WITH TSM FINAL SU72318 QHSM PREPS. REQUEST SFOC SAFETY SU72380 132 CLEAR NONESSENTIAL PERSONNEL FROM OTC NTD INTERIOR AND 10 FT RADIUS OF LO2 232 AND LH2 TSM DOORS FOR FINAL PREPS. NTD *SCC *SCC *PSE NET ESSENTIAL PERSONNEL 105 ------------------- SFOC NASA ---- ---- ORDNANCE TECH 2 ORDNANCE ENGR 1 1 QUALITY CONTROL 1 1 SAFETY 1 1 14-0921 -13H00M NTD ATTENTION ON MLP___: PA ALL NONESSENTIAL PERSONNEL CLEAR INTERIOR OF LH2 AND LO2 TSM'S FOR TSM FINAL PREPS. 14-0922 -13H00M NTD TBC VERIFY LOX/LH2 TSM GN2 PURGES 232 NOT ACTIVATED. TBC CLHY 136 14-0923 CLHY CLH2 CRT (GAH51 TRANSFER LINE - MLP PURGES DISPLAY) VERIFY PF (A129758 LH2 TSM/TUNNEL PGE) OFF PG (A129756 LH2 EMER TSM PGE) OFF PH (A129760 LO2 TSM/TUNNEL PGE) OFF 330 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0924 CLHY TBC LOX/LH2 TSM GN2 PURGES NOT 136 ACTIVATED. TBC NTD 232 NTD OTC *SCC *SCC *PSE NET 105 14-0925 *PSE *SCC INTERIOR AND 10 FT RADIUS OF LH2 NET AND LO2 TSM DOORS CLEARED OF 105 NONESSENTIAL PERSONNEL. YOU HAVE *SCC NTD SAFETY CONCURRENCE TO PROCEED WITH 232 LO2 AND LH2 TSM FINAL PREPS. NTD OTC 14-0926 OTC QOSM BRIEF PERSONNEL ON HAZARDS THAT 132 QHSM WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. WARNING HAZARDOUS STEPS FOLLOW DUE TO ORDNANCE CONNECTION IN LH2 AND LO2 TSM'S. TSM ORDNANCE IS CONNECTED, PERSONNEL WORKING IN TSM AREAS MUST REMAIN CLEAR OF BONNET, DROPWEIGHT AND LANYARD. 14-0927 OTC QOSM PERFORM LOX TSM FINAL PREPS PER 132 OMI V3518. 14-0928 -13H00M OTC QHSM PERFORM LH2 TSM FINAL PREPS PER 132 OMI V3517. 331 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FSS ELEV PHONES TO PTP MODE -------------------------- 14-0929 -13H00M NTD STM CONFIGURE FSS ELEVATOR TELEPHONES COMM 232 TO PTP MODE AND COMM CHECK SU72364 STM GYCC WITH CONSOLE AB-6. (TAG PHONES 111 FOR PTP MODE WITH LCC-1/3). GYCC JYCJ (30 MIN.) 117 JSOQ PTP 14-0930 -12H30M JYCJ GYCC FSS ELEVATOR TELEPHONES HAVE COMM 117 BEEN CONFIGURED TO PTP MODE AND SU72364 GYCC STM COMM CHECKED WITH CONSOLE AB-6. 111 PHONES HAVE BEEN TAGGED FOR STM NTD PTP MODE WITH LCC-1/3. 232 QV:_____ ACTIVATE EPD EXCEPTION MONITORING --------------------------------- 14-0931 -12H30M OTC CEPD ACTIVATE EXCEPTION MONITORING 132 FOR LCC REDLINES. CEPD CURSOR CNTL (SWC02) LCC EMON - ACT XMIT CURSOR KEY - PRESS 14-0932 -12H30M CEPD OTC EPDC LCC EXCEPTION MONITORING 132 COMPLETE. SUPPORT PURGE VERIFICATION -------------------------- 14-0933 -12H15M STM JBPN VERIFY ALL REQUIRED ELECTRICAL PNSA 111 JBFX ENCLOSURES/FACILITIES ARE UNDER WSSA NET VEEE POSITIVE PURGE PER OMI M3054/ CDPD 104 OMI M3176/OMI M3190. SU72357 14-0934 -12H15M STM GYCC VERIFY OIS PURGE/LOCKOUT COMM 111 AND OTV PRESSURIZATION GYCC PSOQ VERIFICATIONS VALID FOR S0007 PTP PER OMI D3008. QV:_____ 332 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- APU EXHAUST DUCT/WSB STEAM VENT ------------------------------- 14-0935 OTC NTD REQUEST SFOC SAFETY CLEAR SU72367 NONESSENTIAL PERSONNEL 275 FT SU72378 AND ABOVE (TO INCLUDE GVA) AND 10 FT AROUND APU EXHAUST DUCTS FOR PLUG/COVER REMOVAL. VERIFY ESSENTIAL PERSONNEL PROPERLY ATTIRED IN FUEL COMPATIBLE RUBBER APRONS, FUEL COMPATIBLE GLOVES AND SAR (CLASS C). REQUEST SAFETY CONCURRENCE TO PROCEED. ESSENTIAL PERSONNEL ------------------- SFOC NASA ---- ---- OMTO 1 QC 1 SAFETY 1 1 14-0936 NTD ATTENTION ON PAD ___: PA ALL NONESSENTIAL PERSONNEL CLEAR 275FT AND ABOVE AND 10 FT RADIUS AROUND APU EXHAUST DUCTS FOR PLUG/COVER REMOVAL. 14-0937 TASK TEAM LEADER/REPRESENTATIVE PERFORM SAFETY INSPECTION OF THE LOCAL CONTROL AREA AND EGRESS ROUTE(S) FROM CONTROL AREA. VERIFY NO DISCREPANCIES WHICH AFFECT THE OPERATION AND/OR SAFE EGRESS FROM THE CONTROL AREA. TASK TEAM LEADER/ REPRESENTATIVE ____________________ DATE __________ 333 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0938 *PSE *SCC CONTROL AREA CLEARED OF NONESSENTIAL NET PERSONNEL AND ESSENTIAL PERSONNEL 105 PROPERLY ATTIRED. YOU HAVE SAFETY *SCC NTD CONCURRENCE TO PROCEED WITH EXHAUST 232 PLUG/COVER REMOVAL. NTD OTC 14-0939 OTC *PAD BRIEF PERSONNEL OF HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE *PAD OMTO SEQUENCES OF APPENDIX Z. WARNING SOME AMMONIA ODOR MAY BE PRESENT DURING APU PLUG REMOVAL. 14-0940 -12H00M OTC *PAD PERFORM ORBITER OPERATION SU72317 132 SUPPORT SETUP 25 - APU EXHAUST DUCT PRESSURE PLUG/COVER REMOVAL AND WSB STEAM VENT CONFIGURATION. TSM FINAL PREPS COMPLETE ------------------------ 14-0941 -12H00M QHSM OTC LH2 TSM FINAL PREPS PER V3517 SU72318 132 COMPLETE. 14-0942 QOSM OTC LOX TSM FINAL PREPS PER V3518 132 COMPLETE. 14-0943 -12H00M OTC NTD VERIFY TSM PURGE SYSTEM NOT 232 ACTIVATED. (PURGE CAPS WILL BE NTD TBC REMOVED AT THIS TIME). 14-0944 TBC CLHY VERIFY LOX/LH2 TSM GN2 PURGES 136 NOT ACTIVATED. 14-0945 CLHY CLH2 CRT (GAH51 TRANSFER LINE - MLP PURGES DISPLAY) VERIFY PF (A129758 LH2 TSM/TUNNEL PGE) OFF PG (A129756 LH2 EMER TSM PGE) OFF PH (A129760 LO2 TSM/TUNNEL PGE) OFF 334 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0946 CLHY TBC TSM PURGES NOT ACTIVATED AT 136 AT THIS TIME. TBC NTD 232 NTD OTC *SCC 14-0947 -12H00M OTC QHSM TSM PURGE SYSTEM NOT ACTIVATED, SU72319 132 QOSM PROCEED WITH TSM CLOSEOUT PER OMI V3517 AND OMI V3518. 14-0948 NTD STM RECONFIGURE ER WX STA CKT COMM 232 2BPC077 FROM LCC PRE-LAUNCH STM GYCC MONITOR CONSOLE TO LCC-1/3 OSR 111 CONSOLE. 14-0949 GYCC JYCJ RECONFIGURE ER WX STA CKT COMM 117 2BPC077 FROM LCC RM 1P12A PRE-LAUNCH MONITOR CONSOLE TO LCC 1/3 OSR CONSOLE A5 PT TO PT PHONE. VERIFY WHEN CIRCUIT OPERATIONAL. (30 MIN) EXTEND GVA ---------- 14-0950 CMEC TBC READY TO EXTEND GOX VENT ARM. SU72377 136 *PAD TBC NTD 232 NTD *SCC 14-0951 CMEC PME4 CLEAR ALL PERSONNEL AND LOOSE EQUIPMENT FROM GOX VENT ARM, HOOD, HOOD ACCESS PLATFORM, ARM LATCHBACK PLATFORM, UPPER AND LOWER HINGE ACCESS PLATFORMS, AND VERIFY NO OBSTRUCTIONS IN ARM SWING PATH. 335 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0952 NTD ATTENTION ON PAD ___: PA GOX VENT ARM WILL BE EXTENDED MOMENTARILY. ALL PERSONNEL CLEAR GOX VENT ARM. WARNING HAZARDOUS OPERATIONS FOLLOW DUE TO GOX VENT ARM EXTEND. 14-0953 PME4 CMEC GOX VENT ARM CLEAR OF ALL 186 PERSONNEL AND LOOSE EQUIPMENT. CMEC TBC HAZARDOUS GOX VENT ARM EXTEND 136 *PAD OPERATIONS COMMENCING. TBC NTD 232 NTD *SCC 14-0954 TBC CMEC BRIEF PERSONNEL OF HAZARDS PRESENT 136 AND APPLICABLE SEQUENCES OF APPENDIX Z EMERGENCY INSTRUCTIONS. NOTE HAZARDOUS OPERATIONS DUE TO EXTENSION OF GVA COMPLETE. 14-0955 CMEC TBC GOX VENT ARM EXTEND COMPLETE. 136 *PAD GOX VENT ARM AREAS OPENED FOR TBC NTD CONTROLLED WORK. 232 NTD *SCC T:______ 336 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LOX PREPS FOR LOAD - COMPLETE ----------------------------- 14-0956 -12H00M CLOX TBC ALL SEQUENCES OF LO2 PREPS SU72294 136 COMPLETE PER G3151 EXCEPT ET PREPS TBC NTD FOR LOADING, STORAGE TANK 232 PRESSURIZATION AND SUCTION LINE CHILLDOWN. NOTE PERFORM NEXT STEP FOR MISSIONS THAT DO NOT REQUIRE LATE ACCESS TO THE SPACELAB OR SPACEHAB USING MVAK. 14-0957 *PAD OTC FD/MD MS SEAT CABLE ROUTING PER SU72337 132 V5097.003 COMPLETE. NOT PERFORMED ______ 14-0958 -11H30M QHSM OTC LH2 TSM CLOSEOUT PER V3517 AND SU72319 132 CAMERA PURGE ACTIVITIES COMPLETE. SU72380 OTC NTD 232 NTD *SCC 14-0959 -11H30M QOSM OTC LOX TSM CLOSEOUT PER V3518 AND 132 CAMERA PURGE ACTIVITIES COMPLETE. OTC NTD 232 NTD *SCC 14-0960 NTD STM TSM AND AFT CLOSEOUT COMPLETE. 232 CONFIGURE ODMS FOR LAUNCH. 14-0961 STM JBEP NOTIFY SPECIAL POWER TECHS PWRA | 111 (1-0702) TO CONFIGURE MLP | LH2 AND LO2 TSM ODMS FOR LAUNCH PER OMI M3088. REPORT COMPLETION. 337 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0962 STM JBEP IF NOT PREVIOUSLY ACCOMPLISHED, PWRA | 111 NOTIFY SPECIAL POWER TECHS | (1-0702) TO CONFIGURE PAD ORBITER AFT ODMS FOR LAUNCH PER OMI M3088. REPORT COMPLETION. NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF ORB ESP LOWERING IS SCHEDULED TO FOLLOW SOUND SUPPRESSION TANK FILL. 14-0963 OTC NTD DEACTIVATE SOUND SUPPRESSION WSSA 232 TRICKLE FLOW SYSTEM PER SU72411 NTD STM OMI M3189.001 (30 MIN.) STM JBWC REPORT COMPLETION. 111 NOT PERFORMED ______ WARNING DO NOT PERFORM LOWER ORBITER ESP TO TRANSPORTER IF SS TANK/MLP LINE FILL TO 105 FT LEVEL IN WORK (48 INCH SS BYPASS VALVES OPEN). LOWER ORBITER ESP TO TRANSPORTER -------------------------------- NOT PERFORMED ______ 14-0964 OTC *PAD VERIFY RSS 107 FT LEVEL DIVING 132 BOARDS RETRACTED AND FLIPS CONFIGURED FOR ORBITER ESP LOWERING. 338 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0965 QESP OTC READY TO PROCEED WITH ORBITER ESP 132 LOWERING OPERATION PER V2270. OTC NTD 232 NTD *SCC 14-0966 OTC QESP CLEAR ALL PERSONNEL FROM ESP AND SU72419 132 ALL NONESSENTIAL PERSONNEL FROM QESP QMTG INSIDE MLP ESP WINCHES AREA AND 25 FT RADIUS OF PLATFORM TRANSPORTER. ESSENTIAL PERSONNEL ------------------- SFOC NASA ---- ---- ENGR 1 1 TECH 8 QC 1 SAFETY 1 1 14-0967 -11H30M NTD ATTENTION ON PAD ___: PA ALL PERSONNEL CLEAR ESP FOR ESP OPERATIONS. ALL NONESSENTIAL PERSONNEL CLEAR THE FOLLOWING CONTROL AREAS FOR ESP OPERATIONS: 1. 25 FT RADIUS OF PLATFORM TRANSPORTER. 2. INSIDE MLP ESP WINCH AREA. 339 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING HAZARDOUS STEPS FOLLOW DUE TO MOVEMENT OF HEAVY EQUIPMENT. 14-0968 QMTG QESP ALL PERSONNEL CLEAR FROM ESP. SU72402 QESP OTC NONESSENTIAL PERSONNEL CLEAR FROM 132 *PAD INSIDE MLP ESP WINCHES AREA AND OTC NTD 25 FT RADIUS OF PLATFORM TRANSPORTER. 232 COMMENCING WITH ORBITER ESP LOWERING NTD *SCC OPERATION. 14-0969 OTC QESP BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. 14-0970 OTC QESP VERIFY HANDRAILS OR TEMPORARY 132 ROPES IN PLACE AROUND MAIN ENGINE BLAST HOLE (V2270). T:______ 14-0971 -11H30M JYCJ GYCC ER WX STA CKT 2BPC077 HAS BEEN COMM 117 RECONFIGURED FROM PRE-LAUNCH GYCC STM MONITOR CONSOLE TO LCC 1/3 OSR 111 CONSOLE A5 AND IS OPERATIONAL. STM NTD 232 14-0972 TBC NTD VERIFY MLP ___ PURGE PANEL PNSA 232 S72-1107-08 IN COMPARTMENT 44A SU72349 NTD STM INDICATES AS FOLLOWS: STM JBPN 111 1. 750 +/- 50 PSI ON GAGE A85427 2. 50 +5/-0 PSI ON GAGE A85434 3. 45 +/-5 PSI ON GAGE A85442 340 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE SRB T-0 UMBILICAL SEAL ------------------------------- CAVITY PURGE ------------ WARNING SRB ESP'S MUST BE LOWERED PRIOR TO NEXT STEP. 14-0973 -11H30M TBC *PAD ACTIVATE GN2 PURGE FOR SRB T-0 SU72345 136 PBOL UMBILICAL SEAL CAVITY AS FOLLOWS (30 MIN): NOTE IN MLP COMPARTMENT 44A, LOCATE PANEL S72-1107-8, GN2 PURGE PANEL (PN 79K07195). 1. VERIFY PRESSURE GAUGE A85427 INDICATES 750 +/- 50 PSI. 2. VERIFY PRESSURE GAUGE A85434 INDICATES 50 +10/-0 PSI. 3. VERIFY PRESSURE GAUGE A85442 INDICATES 40 +10/-0 PSI. NOTE IN COMPARTMENT 37AB LOCATE SHUTOFF VALVE A504064 AT TOP OF STAIRS. (ENTER THROUGH COMPARTMENT 36AB). 4. OPEN SHUTOFF VALVE A504064, SRB T-0 UMBILICAL PURGE. OMRS S00FA0.850 T:______ 341 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONFIGURE HOLD COUNTDOWN ------------------------ 14-0974 -11H20M NTD CGLS HOLD CDC AT T-11 HOURS FOR 232 AN __ HOUR _____ MINUTE HOLD. 14-0975 -11H20M CGLS HOME CMD KEY - PRESS CDTH -1100/00 XMIT CMD KEY - PRESS 14-0976 -11H20M CGLS NTD CDC WILL HOLD AT T-11 HOURS. 232 14-0977 -11H20M NTD OTC CDC WILL HOLD AT T-11 HOURS PA TBC FOR ___ HOURS _____ MINUTES. 232 PTC SRO STM *FLT *MIL *SCC LPS 14-0978 -11H15M STM GYCC UNLOCK DOOR ON MLP I/F TOWER, COMM 111 3RD LVL AND REMOVE INTEGRITY GYCC PSOQ CONTROL SIGN FROM ACCESS PTP PLATFORM. (15 MIN) QV:_____ 14-0979 -11H15M STM QBSE INSTALL BOLTS ON A AND B LEVEL STSA | NET 9099 INTERFACE TOWER DOORS. SU72338 104 REPORT COMPLETION. (15 MIN) T:______ 342 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAD STRUCTURES CLOSEOUT FOR LAUNCH ---------------------------------- 14-0980 STM QBSE PERFORM PAD STRUCTURES CLOSEOUT STSA | NET FOR LAUNCH PER OMI M3134/ SU72515 104 OMI M3083. COMPLETION STEP IN SEQ 15. ESSENTIAL PERSONNEL ------------------- GSS NASA --- ---- SUPER 2 1 ENGR 4 TECH 14 QA 1 343 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- APU COVER RMVL AND WSB STEAM VENT --------------------------------- CONFIGURATION COMPLETE ---------------------- NOTE HAZARDOUS OPERATIONS DUE TO APU EXHAUST DUCT REMOVAL COMPLETE. 14-0981 -11H00M *PAD OTC ORBITER OPERATION SUPPORT SU72317 132 SETUP 25 APU EXHAUST DUCT PRESSURE OTC NTD PLUG/COVER REMOVAL AND WSB STEAM 232 VENT CONFIGURATION COMPLETE. NTD *SCC REQUEST SAFETY CONCURRENCE TO *SCC *PSE OPEN 275 FT AND ABOVE AND 20 FT NET CONTROL AREA AROUND APU EXHAUST 105 DUCTS FOR CONTROLLED WORK. 14-0982 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO SU72378 NET OPEN 275 FT AND ABOVE AND 20 FT 105 CONTROL AREA AROUND APU EXHAUST *SCC NTD DUCTS FOR CONTROLLED WORK. 232 NTD OTC 14-0983 OTC NTD ALL BREATHING AIR REQUIREMENTS LS TBC FOR ORBITER AND SRB COMPLETE. 232 LIFE SUPPORT PERSONNEL RELEASED. NTD STM STM JSTC 111 JSTC *SCB 114 14-0984 OTC *PAD PERFORM ORBITER OPERATION SUPPORT SU72415 132 SETUP 23 PART D - OMS/RCS GSE PRE-LAUNCH SECURING. (3 HRS) 344 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB JOINT HEATER CONFIGURATION CHECKS ------------------------------------- 14-0985 CPWR CURSOR CNTL (BDE11) AUTO SEQ - ALL XMIT CURSOR KEY - PRESS CRT VERIFY ALL PRI HEATERS OPERATING NOMINALLY 14-0986 CPWR CURSOR CNTL (BDE11) AUTO SEQ - ALL XMIT CURSOR KEY - PRESS CRT VERIFY ALL PRI HTR PWR OFF 14-0987 CPWR CURSOR CNTL (BDE11) LH IGN SEC SEL XMIT CURSOR KEY - PRESS CRT VERIFY LH IGN SEC SEL SEC REPEAT FOR: RH IGN SEC SEL LH FWD SEC SEL RH FWD SEC SEL LH MID SEC SEL RH MID SEC SEL LH AFT SEC SEL RH AFT SEC SEL 14-0988 CPWR CURSOR CNTL (BDE11) AUTO SEQ - ALL XMIT CURSOR KEY - PRESS CRT VERIFY ALL SEC HEATERS OPERATING NOMINALLY 345 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-0989 CPWR CURSOR CNTL (BDE11) AUTO SEQ - ALL XMIT CURSOR KEY - PRESS CRT VERIFY ALL SEC HTR PWR OFF 14-0990 CPWR CURSOR CNTL (BDE11) LH IGN SEC SEL XMIT CURSOR KEY - PRESS CRT VERIFY LH IGN SEC SEL PRI REPEAT FOR: RH IGN SEC SEL LH FWD SEC SEL RH FWD SEC SEL LH MID SEC SEL RH MID SEC SEL LH AFT SEC SEL RH AFT SEC SEL 14-0991 -11H00M PBOL *PAD SRB T-0 UMBILICAL SEAL GN2 PURGE SU72345 136 TBC ACTIVATED. OMRSD S00FA0.850 346 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- *** T-11 HOUR HOLD *** ---------------------- 14-0992 -11H00M CGLS NTD CDC HELD AT ____/__ GMT (HOLDING) 232 HHMM SS NOTE PERFORM NEXT STEP AFTER CDC IS HOLDING. 14-0993 -11H00M CGLS HOME CMD KEY - PRESS (HOLDING) CDTC ____/__.000 HHMM SS (GMT OF CDC RESUME) XMIT CMD KEY - PRESS ANNOUNCE HOLD ------------- 14-0994 -11H00M NTD OTC CDC HOLDING AT T-11 HOURS. SU72386 (HOLDING) PA TBC DURATION OF HOLD WILL BE 232 *FLT ___ HOURS ___ MINUTES. *MIL STM PTC *SCC LPS 14-0995 -11H00M CGLS NTD __ HOUR ___ MINUTE HOLD (HOLDING) 232 TERMINATES AND CLOCK WILL RESUME AT ____/__ GMT HHMM SS 347 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORMANCE OF NEXT TWO STEPS WILL BE SCHEDULED REALTIME BY TEST TEAM. 14-0996 NTD CTC VERIFY READY TO ACTIVATE OIS-D 232 LAUNCH SUPPORT PERMISSION CONFIGURATION FOR LCC-2. 14-0997 NTD STM ACTIVATE OIS-D LAUNCH SUPPORT COMM 232 PERMISSION CONFIGURATION FOR STM GYCC LCC-2 (REF KICS). REPORT 111 COMPLETION. GYCC JYCD 117 ORBITER GN&C POWER UP AND SWITCH -------------------------------- CONFIGURE (L-28H00M) -------------------- NOTE FOLLOWING STEP PERFORMS A SYSTEMATIC PANEL BY PANEL SWITCH CONFIGURE OF FOLLOWING GN&C SYSTEMS: AA, ADTA, ASA, ATVC, BRAKES, CONTROLLERS, NWS, RJD LOGIC, RGA, RMS, STAR TRACKER AND SWITCHES. FOLLOWING STEP WILL REQUIRE AN I/O RESET. DPS CAN EXPECT I/O ERRORS TO OCCUR FOR ITEMS NOT POWERED UP AT THIS TIME. 14-0998 -11H00M OTC COFC PERFORM GN&C SYSTEM POWER UP PER SU72393 (HOLDING) 132 CGNC OMI V1123. (30 MIN) (CDR) CDPS RT OMI LOG NO__________ 14-0999 COFC OTC GN&C SYSTEM POWER UP COMPLETE. CGNC 348 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1000 COFC CRT (VWB03, PAGE B) VERIFY AEROSURFACE DRIVER CURRENTS LOB/ROB DRVRS 0 +/- 3.25 MA LIB/RIB DRVRS 0 +/- 3.00 MA RUD DRVRS 0 +/- 2.00 MA SPBK DRVRS: SPBK POSN (DEG) DRV CURR LIMITS (MA) --------------- -------------------- 1.POSN >= 5.0 -2.0 TO +2.0 2.POSN < 5.0 AND DRV >=(-1.33 (POSN)+4.67) POSN >= 3.5 AND DRV <= +2.0 3.POSN < 3.5 0.0 TO +2.0 DEU 3 TO CONSOLE C11 -------------------- NOTE DEU IS REQUIRED FOR THE RCS SINGLE COMMAND TEST ONLY AND IS NOT A PREREQUISITE FOR ANY OTHER GNC/EFC SYSTEM ACTIVATION. 14-1001 COFC OTC CHANGE RESPONSIBLE CONSOLE FOR 132 DEU 3 TO CONSOLE C11. OTC CDPS 14-1002 CDPS CONSOLE KYBD HOME CMD KEY - PRESS ISSU N72IV102D #B00B XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS HOME CMD KEY - PRESS C CO _DEU3G LDBA C11 XMIT CMD KEY - PRESS 14-1003 CDPS OTC RESPONSIBLE CONSOLE FOR DEU NO. 3 132 NOW ASSIGNED TO C11. OTC COFC 349 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GN&C SYSTEM SELF TESTS (L-27H30M) --------------------------------- NOTE FOLLOWING ARE INDEPENDENT OPERATIONS AND MAY BE PERFORMED IN PARALLEL, IN ANY ORDER, AND IN CONJUNCTION WITH IMU OR STAR TRACKER OPERATIONS. DOWNLIST FORMAT 42 NOT REQUIRED FOR COUNTDOWN RJD SINGLE CMD TEST. DO NOT CHANGE TO FORMAT 42 (PER V1123) UNLESS THIS TEST MUST BE USED TO VERIFY RJD DRIVER OUT DISCRETES. 14-1004 OTC COFC PERFORM GN&C SYSTEM SELF TESTS SU72397 132 CGNC PER OMI V1123. 1. ADTA SELF TEST (5 MIN) 2. ORBITER RGA TURNAROUND NULL/SELF TEST (GROUND TEST). (10 MIN) 3. AA TURNAROUND SELF TEST (10 MIN). 4. RCS TRICKLE CURRENT SINGLE CMD TEST (NORMAL JETS ONLY). (15 MIN) RT OMI LOG NO.__________ 350 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IMU WARM-UP/STANDBY (L-27H30M) ------------------------------ NOTE IMU WARM-UP/STANDBY SHALL OCCUR NO LATER THAN L-15H20M. FOLLOWING STEP WILL REQUIRE ECL TO ACTIVATE ONE IMU FAN TO SUPPORT IMU OPERATIONS FOR REMAINDER OF THIS OMI. IMU AND STAR TRACKER ARE INDEPENDENT OPERATIONS AND MAY BE PERFORMED IN PARALLEL. 14-1005 OTC CGNC PERFORM ORBITER IMU POWER UP/ SU72399 132 STANDBY OPERATIONS PER OMI V1123. (30 MIN) (5 MIN W/CDR) RT OMI LOG NO.__________ 351 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- STAR TRACKER FUNCTIONAL C/O (L-27H30M) -------------------------------------- NOTE THE STAR TRACKER C/O IS REQUIRED ONE TIME PRIOR TO LAUNCH, MAKING THE REPEAT OF THE TEST OPTIONAL FOR A RECYCLE LAUNCH COUNTDOWN. DO NOT PERFORM THIS TEST IF IT HAS BEEN PERFORMED IN THE PREVIOUS COUNTDOWN UNLESS THERE IS CONCERN OVER ACTIVITY IN THE GENERAL LRU AREA OR CONCERN OVER POSSIBLE TREND DATA OR CONCERN OVER TIME ELAPSED SINCE LAST TEST. FOLLOWING STEP WILL REQUIRE AN I/O RESET. DPS CAN EXPECT I/O ERRORS TO OCCUR FOR ITEMS NOT POWERED UP AT THIS TIME. STAR TRACKER C/O CAN BE PERFORMED BEFORE OR AFTER BUT NOT IN PARALLEL WITH SWITCHLIST PART OF GNC SYSTEM POWER UP. SWITCH POSITIONS ARE INCOMPATIBLE FOR BOTH OPERATIONS. 14-1006 OTC CGNC PERFORM STAR TRACKER FUNCTIONAL SU72395 132 CHECKOUT PER OMI V1123. 1. STAR TRACKER POWER UP (20 MIN) (5 MIN W/CDR) 2. STAR TRACKER SELF TEST (5 MIN) 3. STAR TRACKER POWER DOWN (5 MIN) (CDR) RT OMI LOG NO.__________ NOT PERFORMED ______ 352 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IMU POWER UP/STANDBY COMPLETE (L-27H00M) ---------------------------------------- 14-1007 CGNC OTC IMU POWER UP/STANDBY COMPLETE. SU72399 132 STAR TRACKER CHECKOUT COMPLETE (L-27H00M) ----------------------------------------- NOTE PERFORM NEXT STEP IF STAR TRACKER CHECKOUT IS PERFORMED THIS RUN. 14-1008 CGNC OTC STAR TRACKER CHECKOUT COMPLETE. SU72395 132 NOT PERFORMED ______ GN&C SYSTEM SELFTESTS COMPLETE (L-26H50M) ----------------------------------------- 14-1009 COFC OTC GN&C SYSTEM SELFTESTS COMPLETE. SU72397 CGNC 132 DEU3 RETURN TO C12 ------------------ 14-1010 COFC CONSOLE KYBD ISSU N72IV102D 0 XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS C CO _DEU3G LDBA C12 XMIT CMD KEY - PRESS 14-1011 COFC OTC RESPONSIBLE CONSOLE FOR DEU 3 IS 132 CDPS NOW C12. 353 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- REDUNDANT WEIGHT ON WHEELS (RWOW) STATUS ---------------------------------------- NOTE NEXT TWO STEPS REQUIRE BRAKE AND ANTISKID POWER. RWOW DISCRETES ARE NOT AVAILABLE IN DL FMT 60. PERFORM NEXT STEP IF IN DL FMT 60. 14-1012 COFC APPL PG (VWB37 PG-B) PFK 5 KEY - PRESS (LDB READ) NOT PERFORMED ______ 14-1013 COFC CRT (VWB37 PG-B) BRAKES STATUS AND TEST SELECT LANDING GEAR STATUS VERIFY "RWOW" STATUS = ON/UP ARROW (U) R NO WOW 1U 2U 3U 4U NULL FAIL 1U 2U 3U 4U OMRSD V51AF0.250 LANDING GEAR NO WOW STATUS CHECKS --------------------------------- 14-1014 COFC CRT (VWB37 PG B) BRAKE STATUS AND TEST SELECT LANDING GEAR STATUS L N R - - - NO WOW 1 ON ON ON NO WOW 2 ON OMRSD V51AF0.245-1R 354 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GNC LCC MONITOR ACTIVATION -------------------------- NOTE PERFORM NEXT STEP AFTER COMPLETION OF GN&C SYSTEM POWER UP, GN&C SYSTEM SELF TESTS AND IMU POWER UP. ALLOW ONE TO TWO MINUTES FOR NEXT STEP TO COMPLETE. ACTIVATION OF THE GN&C LCC MONITOR SATISFIES THE LISTED REQUIREMENT BY THE ABSENCE OF A LCC GNC-26 FAILURE ANNUNCIATION. 14-1015 COFC CURSOR CONTROL (SAB20/VSB79 PG B) ACTIVATE LCC MONITOR XMIT CURSOR KEY - PRESS OMRSD S00FM0.110-1R (SWB02) ACTIVATE IMU PWR UP LCC EMON ---------------------------- 14-1016 CGNC APPL PG A (SAB20/SWB02) PFK13 KEY - PRESS (ACT EMON SETUP) 14-1017 CGNC CURSOR CONTROL (SAB20/SWB02 PG A) A-IMU PWR UP XMIT CURSOR KEY - PRESS 14-1018 CGNC APPL PG A (SAB20/SWB02) PFK13 KEY - PRESS (DEACT EMON SETUP) 355 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLEAR GNC LCC DISK FILES ------------------------ 14-1019 COFC APPL PG B (SAB20/SWB02) PFK 3 KEY - PRESS (PARAM ACT/INH PG) NOTE REPEAT NEXT STEP FOR ALL LCC PARAMETER PAGES TO CLEAR (NON-INVERT) ANY INHIBITED LCC PARAMETER. 14-1020 COFC CURSOR CNTL (SAB20/SWB02 PG B) (ON ITEMS BELOW) XMIT CURSOR KEY - PRESS 1. (ON ANY INVERTED PARAMETER) 2. PAGE AHEAD 14-1021 COFC APPL PG B (SAB20/SWB02) PFK 5 KEY - PRESS (LCC MONITOR ACTIVITY PG) GNC OPS101 PROFILE MON SETUP ---------------------------- 14-1022 COFC CURSOR CNTL (SAB19/SWB01 PG-B) COUNTDOWN - DETAIL XMIT CURSOR KEY - PRESS 14-1023 COFC APPL PAGE (VWB05 PG-B) PFK 8 KEY - PRESS (CLEAR ALL BYPASSES) PFK 15 KEY - PRESS (TERMINATE) 356 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LG NOWOW EMON SETUP ------------------- 14-1024 COFC CONSOLE KYBD I SX FD XMIT CMD KEY - PRESS A SX FD OFF XMIT CMD KEY - PRESS REPEAT FOR; FD ---------- V51X0130X1 LMG NO WOW V51X0230X1 RMG NO WOW V51X0330X1 NLG NO WOW NO. 1 V51X0335X1 NLG NO WOW NO. 2 DEFLATE DOCK SEALS AND INSPECT ------------------------------ NOTE PERFORM TILE INSPECTION APPROXIMATELY 8 HOURS PRIOR TO RSS MOVE. 14-1025 *PAD OTC DEFLATE DOCK SEALS PER OMI V1122 SU72392 132 "DOCK SEAL INFLATION/DEFLATION, OTC PPVM OPTION C". REPORT COMPLETION. RT OMI LOG NO.__________ 357 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1026 OTC PQCG VISUALLY INSPECT PCR SEAL/TPS SU72394 132 INTERFACE ORB AREA APPROXIMATELY 1 FOOT INBOARD AND OUTBOARD FROM CENTER LINE (COORDINATE) OF SEAL CONTACT; ACROSS UPPER FORWARD FUSELAGE L/H TO R/H SIDE FROM Z=402.75 AT X=564.5; ACROSS UPPER AFT FUSELAGE L/H TO R/H SIDE FROM Z=402.75 AT X=1323; ALONG MID FUSELAGE L/H AND R/H SIDES FROM X=564.5 TO X=1323 AT Z=402.75. DOCUMENT EVIDENCE OF BROKEN TILES OR APPARENT TILE DEGRADATION. INSPECT FI OML SURFACE AND VISIBLE EDGES FOR CUTS, TEARS, FRAYED AREAS, AND BROKEN QUILTING STITCHES IN EXCESS OF SPECIFICATION ALLOWABLES. INSPECT CERAMIC COATING FOR FLAKING, MISSING COATING AND EVIDENCE OF CONTAMINATION AND/OR DISCOLORATION. INSPECT FOR EVIDENCE OF BLANKET JOINT GAPS OPENING OR OUT OF TOLERANCE STEPS DEVELOPING. REPORT COMPLETE. DOCUMENT EVIDENCE OF UNACCEPTABLE CRACKED COATING, BUTT JOINT SEPARATION, ABNORMAL DISCOLORATION, EMBRITTLEMENT, TEARS, CUTS OR RIPS IN FRSI MATERIAL. UPPER FORWARD FUSELAGE TQWN:___ UPPER AFT FUSELAGE TQWN:___ R/H MID FUSELAGE TQWN:___ L/H MID FUSELAGE TQWN:___ OMRSD V09AH0.090-1 358 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF WINDS HIGH ENOUGH TO CAUSE FLAPPING OF DOCK SEALS AND CAUSE DAMAGE TO TPS/TILE. 14-1027 OTC *PAD REINFLATE DOCK SEALS PER OMI V1122. 132 PPVM REPORT COMPLETION. RT OMI LOG NO.__________ NOT PERFORMED ______ 14-1028 *PAD OTC OMS/RCS SECURING COMPLETE PER SU72415 132 ORBITER OPERATION SUPPORT SETUP 23 PART D. 14-1029 OTC *PAD PERFORM ORBITER OPERATION SU72389 132 SUPPORT SETUP 29 - MLP INTERIOR *PAD QMTG SECURING. (8 HRS) BIRD DETERRENT REMOVAL ---------------------- NOTE PERFORM NEXT STEP DURING THE BREEDING SEASON (APRIL THROUGH JULY) OR AS DIRECTED BY NTD. 14-1030 NTD OTC REMOVE AND STORE DECOY OWLS, TERROR 232 EYES BALLONS, MYLAR STREAMERS, AND OTC *PAD WATER HOSES. RELOCATE TO LCC TO 132 MONITOR OTV CAMERAS FOR ANY BIRD *PAD ACM ACTIVITY UNTIL RELEASED BY NTD. NOT PERFORMED ______ 359 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP WHEN SSME ESP OPS COMPLETE. UCOM/GSS TECHS MEET AT BASE OF FSS ELEVATOR. 14-1031 NTD STM UCOM REMOVE TWO (2) PORTABLE PNSA 232 OIS UNITS POSITIONED 30/40 FT COMM STM GYCC OUT FROM FSS IN CRAWLERWAY, ONE 111 JBPN UNIT ON EAST PAD SURFACE AND ONE GYCC JYCD UNIT ON WEST PAD SURFACE. GSS 117 REMOVE PURGE FLEXHOSES FROM UNITS. UCOM T:______ GSS T:______ 14-1032 JBPN STM PURGE FLEXHOSES DISCONNECTED PNSA 111 FOR REMOVAL OF TWO OIS BOXES ON EAST/WEST PAD SURFACE. 14-1033 JYCD GYCC TWO PORTABLE OIS UNITS ON COMM 117 EAST AND WEST PAD SURFACE GYCC STM HAVE BEEN REMOVED. CAPS 111 INSTALLED ON CABLE CONNECTORS. STM NTD 232 TRANSPORTER TO LAUNCH POSITION ------------------------------ 14-1034 -11H00M *PAD OTC ORBITER ESP LOWER TO TRANSPORTER SU72402 (HOLDING) 132 PER V2270 COMPLETE. READY FOR SU72419 OTC NTD ESP TRANSPORTER MOVE TO LAUNCH 232 POSITION. NTD *SCC STM *SCC *PSE NET 105 360 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1035 NTD STM PROVIDE TOW VEHICLES AND STSA | 232 PERSONNEL TO SUPPORT HESA STM QBSE ENGINE SERVICE PLATFORM NET TRANSPORTER MOVE TO LAUNCH 104 POSITION PER OMI V2274 (Q3208) 111 JBDY (M3134). JBDY GBHE NET 104 WARNING DO NOT PERFORM ESP TRANSPORTER MOVE IF SS TANK/MLP LINE FILL TO 105 FT LEVEL IN WORK (48 INCH SS BYPASS VALVES OPEN). 14-1036 *PAD PMTG CLEAR ALL NONESSENTIAL PERSONNEL SU72420 FROM AREA 25 FT EACH FLAME TRENCH TRACKS. ESSENTIAL PERSONNEL ------------------- SFOC GSS NASA | ---- --- ---- | SYS ENGR 1 1 TECH 4 5 QC 1 1 SAFETY 1 1 | NOT PERFORMED ______ 361 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1037 NTD ATTENTION ON PAD ___: PA ALL NONESSENTIAL PERSONNEL CLEAR 25 FT FROM EACH SIDE OF FLAME TRENCH TRACKS FOR ESP TRANSPORTER MOVE. NOT PERFORMED ______ 14-1038 TTL TASK TEAM LEADER/REPRESENTATIVE PERFORM SAFETY INSPECTION OF THE LOCAL CONTROL AREA AND EGRESS ROUTE(S) FROM CONTROL AREA. VERIFY NO DISCREPANCIES WHICH AFFECT THE OPERATION AND/OR SAFE EGRESS FROM THE CONTROL AREA. (V2274) TASK TEAM LEADER/ REPRESENTATIVE ____________________ DATE __________ NOT PERFORMED ______ WARNING HAZARDOUS STEP FOLLOWS DUE TO MOVING OF LARGE HEAVY EQUIPMENT. 14-1039 PMTG *PAD 25 FT CONTROL AREA SETUP AROUND SU72404 132 ESP TRANSPORTER. COMMENCING SU72409 *PAD OTC WITH ESP TRANSPORTER MOVE TO OTC NTD LAUNCH POSITION PER OMI V2274 232 (Q3208, M3134). NTD STM *SCC NOT PERFORMED ______ 14-1040 OTC *PAD BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE *PAD PMTG SEQUENCES OF APPENDIX Z. NOT PERFORMED ______ 362 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP ONLY DURING DAYLIGHT HOURS ON L-1 DAY. THE TIME FOR THE COMM CHECK WILL BE COORDINATED WITH LCC VITT (7-4792) TO ENSURE ALL PARTIES WILL BE AVAILABLE TO ACCOMPLISH THE COMM CHECK. 14-1041 GYCC JYCD INSTALL PORTABLE OIS-D UNIT COMM 117 WITH SPEAKER ON LCC ROOF. PERFORM COMM CHECK ON OIS-D CHANNEL 6228: 1. LCC ROOF COMM CHECK WITH O&C FLT CREW QUARTERS. 2. LCC ROOF COMM CHECK WITH CR-1 OR CR-3 OSR CONSOLE A6. 3. LCC ROOF COMM CHECK WITH LCC VITT. NOTE PERFORM NEXT STEP ONLY DURING DAYLIGHT HOURS. 14-1042 STM GYCC REMOVE PAGING AND AREA WARNING COMM 111 SYSTEM PIVOT SPEAKERS NO. 17 AND GYCC JYCJ NO. 18 ON EAST STAIRWELL AT PAD 117 SURFACE. STORE CABLES IN BOX PROVIDED. (COMPLETION 30 MIN PRIOR TO END OF HOLD) T:______ 363 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- REPLENISH SOUND SUPPRESSION WATER --------------------------------- NOTE PERFORM NEXT STEP ONLY IF THIS SEQUENCE IS PERFORMED FOLLOWING A SCRUB TURNAROUND AND SS WATER LEVEL IS LOW. 14-1043 STM JBWC TOP OFF ELEVATED SOUND WSSA 111 SUPPRESSION WATER TANK PER OMI M3189.001. (SEE JBWC FIG 2) (30 MIN) NOT PERFORMED ______ 14-1044 -11H00M PSOQ GYCC DOOR ON MLP I/F TOWER, 3RD LEVEL COMM (HOLDING) PTP UNLOCKED AND INTEGRITY CONTROL GYCC STM SIGN REMOVED FROM ACCESS PLATFORM. 111 14-1045 *PAD TBC ET PRE-PROPELLANT LOAD SU72346 136 INSPECTION REQUIRING +Y/-Y OWP SU72383 TBC NTD COMPLETE. (T6446 SEQ 03) 232 READY TO RETRACT OWP. REPOSITION WX PROTECTION PANEL ------------------------------ 14-1046 NTD STM READY TO PROCEED WITH +Y OWP SU72421 232 OTC RETRACT. ESTABLISH CLEAR AROUND *SCC Y OWP PER OMI M3169 (TASK 05). OTC *PAD 132 364 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1047 STM QBSE CLEAR NONESSENTIAL PERSONNEL STSA | NET FROM 25 FT RADIUS UNDER SIDE 2 +Y 104 CURTAIN WALL ON MLP ZERO LEVEL. ESSENTIAL PERSONNEL ------------------- ELEMENT SFOC NASA ------- ---- ---- SYS ENGR 3 2 1 SUPV 1 1 TECH 5 5 QC 1 1 1 SAFETY 1 1 1 14-1048 STM ATTENTION ON PAD___/MLP ZERO LEVEL. PA ALL NONESSENTIAL PERSONNEL CLEAR 25 FT RADIUS FROM UNDER SIDE 2 +Y CURTAIN WALL TRAVEL PATH. 14-1049 TTL TASK TEAM LEADER/REPRESENTATIVE STSA | PERFORM SAFETY INSPECTION OF THE LOCAL CONTROL AREA AND EGRESS ROUTE(S) FROM CONTROL AREA. VERIFY NO DISCREPANCIES WHICH AFFECT THE OPERATION AND/OR SAFE EGRESS FROM THE CONTROL AREA. TASK TEAM LEADER/ REPRESENTATIVE ____________________ DATE __________ 365 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1050 QBSE STM NONESSENTIAL PERSONNEL CLEARED STSA | NET FROM 25 FT RADIUS UNDER SIDE 2 SU72410 104 +Y CURTAIN WALL FOR RETRACT STM NTD OPERATION. COMMENCING WITH +Y 232 OWP RETRACTION AND +Y GUIDE NTD OTC RAIL PER OMI M3169 (TASK 05). *SCC (45 MIN) OTC *PAD 132 14-1051 STM QBSE BRIEF PERSONNEL ON ALL HAZARDS STSA | NET THAT WILL BE PRESENT AND 104 APPLICABLE SEQUENCES OF APPENDIX Z. ET/ORB DISC INSTRUMENTATION --------------------------- INSTALL VERIFICATION -------------------- NOTE DO NOT PERFORM NEXT STEP IF ET 17 IN. HYDROGEN LEAK DETECTOR'S SAMPLE LINES ALREADY IN PLACE. 14-1052 CTIF TBC HYDROGEN LEAK DETECTOR SU72344 136 INSTALLATION AND CHANNELIZATION COMPLETE PER T5401. NOT PERFORMED ______ 366 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- REPOSITION OF -Y WX PROTECTION -------------------------------- PANELS ------ NOTE DO NOT PERFORM NEXT STEP IF ET GUIDERAILS STOWED. 14-1053 STM QBSE REPOSITION RSS SIDE 4 -Y ET STSA | NET GUIDERAILS TO STOW POSITION SU72372 104 PER OMI M3169. NOT PERFORMED ______ 14-1054 NTD STM READY TO PROCEED WITH -Y OWP SU72421 232 OTC RETRACT. ESTABLISH CLEAR AROUND *SCC Y OWP PER OMI M3169 (TASK 05). OTC *PAD 132 14-1055 STM QBSE CLEAR NONESSENTIAL PERSONNEL STSA | NET FROM 25 FT RADIUS UNDER SIDE 4 -Y 104 CURTAIN WALL ON MLP ZERO LEVEL. ESSENTIAL PERSONNEL ------------------- ELEMENT SFOC NASA ------- ---- ---- SYS ENGR 3 2 1 SUPV 1 1 TECH 5 5 QC 1 1 1 SAFETY 1 1 1 14-1056 STM ATTENTION ON PAD___/MLP ZERO LEVEL: PA ALL NONESSENTIAL PERSONNEL CLEAR 25 FT RADIUS UNDER SIDE 4 -Y CURTAIN WALL TRAVEL PATH. 367 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING HAZARDOUS OPERATIONS FOLLOW DUE TO MOVING HEAVY MACHINERY IN CLOSE PROXIMITY TO VEHICLE AND WORKING AT UNPROTECTED HEIGHTS. 14-1057 QBSE STM NONESSENTIAL PERSONNEL CLEARED STSA | NET FROM 25 FT RADIUS UNDER SIDE 4 104 -Y CURTAIN WALL FOR RETRACT STM NTD OPERATION. COMMENCING WITH -Y 232 OWP RETRACTION. NTD OTC *SCC OTC *PAD 132 14-1058 STM QBSE BRIEF PERSONNEL ON HAZARDS THAT STSA | NET WILL BE PRESENT AND APPLICABLE 104 SEQUENCES OF APPENDIX Z. | 368 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM SRB OI POWER-UP FOR MEASUREMENT SNAPSHOT IF A SRB OI SNAPSHOT IS REQUIRED TO VERIFY FSM PRESSURE. SRB OI POWER-UP FOR MEASUREMENT ------------------------------- SNAPSHOT -------- NOT PERFORMED ______ 14-1059 TBC CPWR PERFORM SRB OI BUS A AND B POWER 136 CBDP UP PER S9001VL1, OPTION B. RT OMI LOG NO.__________ 14-1060 CPWR TBC SRB OI BUS A AND B POWER APPLICATION 136 COMPLETE. TBC NTD 232 14-1061 TBC CBHY PERFORM MEASUREMENT SNAPSHOT USING 136 BAT04 AND REPORT COMPLETION. 369 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1062 TBC CPWR PERFORM SRB OI BUS A AND B POWER 136 CBDP DOWN PER S9001VL1. RT OMI LOG NO.__________ 14-1063 CPWR TBC SRB OI BUS A AND B POWER DOWN COMPLETE. 136 READY FOR MEC PRE FLT BITE EVALUATION. TBC NTD 232 NTD OTC 14-1064 OTC CEPD PERFORM MEC PREFLT BITE EVALUATION. 132 14-1065 CEPD PERFORM CDS QLDB RETRIEVAL ON FD VERIFY NO MEC FAILURES SRB OI POWER UP FOR MEASUREMENT ------------------------------- SNAPSHOT COMPLETE ----------------- 370 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LRD L - 1 DAY VERIFICATIONS --------------------------- NOTE SOME LANDING SITES MAY NOT BE MANNED DUE TO MISSION REQUIREMENTS. 14-1066 -11H00M LRD VERIFY NO OPEN ITEMS/CONSTRAINTS (HOLDING) LF1 IDENTIFIED FOR LAUNCH. NOT SITE GO NO/GO MANNED ---- -- ----- ------ BANJUL ______ ______ ______ BEN GUERIR ______ ______ ______ ZARAGOZA ______ ______ ______ MORON ______ ______ ______ DFRF ______ ______ ______ WSSH ______ ______ ______ 371 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LCC2 CONFIGURATION ------------------ 14-1067 NTD CTC VERIFY READY TO ACTIVATE LCC-2 232 LPS LAUNCH SUPPORT CONFIGURATION. 14-1068 -11H00M NTD LPS PERFORM SUPPORT OPERATION SU72405 (HOLDING) 232 SUPPORT SETUP 2 - LCC2 LAUNCH SUPPORT CONFIGURATION - LPS T-11 HOUR BIH TO T+45 MIN (8 HR). NOTE PERFORM NEXT STEP IF NOT PREVIOUSLY PERFORMED FOR PAYLOAD SUPPORT. 14-1069 NTD LPS PERFORM SUPPORT OPERATION SUPPORT 232 SETUP 4 - LCC2 PAYLOAD SUPPORT CONFIGURATION. NOT PERFORMED ______ 14-1070 LPS JSDC CONFIGURE PCGOAL FOR LCC2 | 127 TO S0007 DATA ONLY. 14-1071 LPS JRPS VERIFY KMTS 505A1 (A1,A2,A3,A7,A8,A9) | BIT SYNCS ON MANUAL MODE, SOURCE 1, | 60KB RATE. 372 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ESA MONITOR PATCHING -------------------- 14-1072 -11H00M NTD LPS PERFORM ESA MONITOR PATCHING PER (HOLDING) 232 OMI C3041 AND REPORT COMPLETE (1 HR). VERIFY FIRING ROOM CONSUMABLES | ------------------------------ | 14-1073 -11H00M LPS VERIFY FIRING ROOM CONSUMABLES. | (HOLDING) | NOTE PERFORM NEXT STEP ON FIRST SHIFT. 14-1074 STM GYCC VERIFY VIP PAGING SYSTEM COMM 111 OPERATIONAL. (1 HR) GYCC JYCJ 117 373 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WX SATELLITE PHOTOS ------------------- NOTE NEXT STEP PERFORMED 1 HOUR PRIOR TO L-1 DAY WEATHER BRIEFING. 14-1075 NTD STM VERIFY THAT THE FULL DISK SU72371 232 WEATHER SATELLITE PHOTO HAS BEEN STM *WEA EMAILED TO THE ASTRONAUT CREW | 231 QUARTERS (TO THOMAS.W.KWIATKOWSKI1 | @JSC.NASA.GOV). | ESP TRANSPORTER SECURE FOR -------------------------- LAUNCH - COMPLETE ----------------- 14-1076 -11H00M GBHE JBDY ESP TRANSPORTER POSITIONED FOR HESA (HOLDING) JBDY STM LAUNCH PER V2274. SU72404 111 SU72409 14-1077 PMTG *PAD ESP TRANSPORTER MOVE TO LAUNCH 132 POSITION COMPLETE. READY FOR *PAD OTC SKYJACK MINI-MANLIFT HOIST FROM OTC NTD ORBITER ESP. ESP CONTROL AREA 232 WILL BE MAINTAINED. NTD STM *SCC 14-1078 NTD STM PROVIDE MOBILE CRANE AND HESA 232 PERSONNEL FOR SKYJACK MINI-MANLIFT STM JBDY HOIST FROM ORBITER ESP. VERIFY 111 10 FT CONTROL AREA SETUP AROUND JBDY GBHE ESP TRANSPORTER. NET 104 374 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1079 TTL TASK TEAM LEADER/DESIGNATED HESA FLOOR LEADER (DFL) PERFORM SAFETY INSPECTION OF THE LOCAL CONTROL AREA AND EGRESS ROUTE(S) FROM CONTROL AREA. VERIFY NO DISCREPANCIES EXIST WHICH COULD AFFECT THE OPERATION AND/OR SAFE EGRESS FROM THE CONTROL AREA. DATE__________ TTL ______ WARNING HAZARDOUS STEP FOLLOWS DUE TO LIFTING OF HEAVY EQUIPMENT. 14-1080 GBHE JBDY 10 FT CONTROL AREA SETUP AROUND HESA NET ESP TRANSPORTER COMMENCING WITH 104 SKYJACK MINI-MANLIFT HOIST FROM JBDY STM ORBITER ESP. WILL LOAD AND 111 TRANSPORT MANLIFTS TO VAB CELL 1. STM NTD (ROCKETDYNE SSME AREA) 232 NTD *SCC 14-1081 STM JBDY BRIEF PERSONNEL ON HAZARDS THAT HESA 111 WILL BE PRESENT AND APPLICABLE JBDY GBHE SEQUENCES OF APPENDIX A. NET 104 14-1082 GBHE JBDY SKYJACK MINI-MANLIFT HOISTING HESA NET OPERATIONS COMPLETE. ESP SU72420 104 CONTROL AREA OPEN FOR CONTROLLED JBDY STM WORK. 111 STM NTD 232 NTD *SCC 14-1083 JYCJ GYCC VIP PAGING SYSTEM OPERATIONAL. COMM 117 GYCC STM 111 375 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- +Y WX PROTECTION PNL RETRACTION --------------------------------- COMPLETE -------- 14-1084 QBSE STM +Y WEATHER PROTECTION PANEL STSA | NET AND +Y GUIDE RAIL RETRACTION SU72410 104 COMPLETE. CONTROL AREA OPEN STM NTD FOR CONTROLLED WORK. 232 NTD OTC *SCC OTC *PAD 132 NOTE HAZARDOUS OPERATIONS DUE TO +Y WX PROTECTION PANEL RETRACTION COMPLETE. -Y WX PROTECTION PNL RETRACTION --------------------------------- COMPLETE -------- 14-1085 QBSE STM -Y WEATHER PROTECTION PANEL STSA | NET AND -Y GUIDE RAIL RETRACTION 104 COMPLETE. CONTROL AREA OPEN STM NTD FOR CONTROLLED WORK. 232 NTD OTC *SCC OTC *PAD 132 NOTE HAZARDOUS OPERATIONS DUE TO -Y WX PROTECTION PANEL RETRACTION COMPLETE. 376 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLEAR FOR SS LINES AND TANK FILL -------------------------------- NOTE DO NOT PERFORM NEXT NINE STEPS FOR SCRUB TURNAROUND IF TANK REMAINS FULL. 14-1086 STM NTD REQUEST SFOC SAFETY CLEAR SU72382 232 FOLLOWING AREAS FOR SS LINE NTD *SCC AND TANK FILL: *SCC *PSE NET 1. FLAME TRENCH 105 2. SRB AND SSME ESP'S ESSENTIAL PERSONNEL ------------------- GSS SFOC NASA --- ---- ---- SUPERV/ENGR 2 SYS TECHS 2 QA 1 SAFETY 1 1 NOT PERFORMED ______ 14-1087 NTD ATTENTION ON PAD _____: PA ALL NONESSENTIAL PERSONNEL CLEAR FLAME TRENCH, ORBITER AND SRB ESP'S FOR SOUND SUPPRESSION LINE AND TANK FILL. NOT PERFORMED ______ 377 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1088 STM JBWC CONDUCT ON NET COMM CHECK WITH WSSA 111 ALL SOUND SUPPRESSION LINE AND TANK FILL OBSERVERS/OPERATORS PER OMI M3189.001. BRIEF PERSONNEL ON HAZARDS THAT ARE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. NOT PERFORMED ______ NOTE MLP ZERO LEVEL MAY REMAIN OPEN FOR ACCESS WHEN SS HYD VALVE LOCKS ARE ON AND OPEN COMMAND LOCKOUT IS ON. 14-1089 JBWC STM SOUND SUPPRESSION ON NET BRIEFING WSSA 111 COMPLETE. NOT PERFORMED ______ 14-1090 -11H00M NTD STM VERIFY SS HYD VALVE LOCKS ARE ON, WSSA (HOLDING) 232 OPEN COMMAND LOCKOUT ISSUED AND STM JBWC GN2 PRESSURE TO CLOSE ACTUATORS. 111 NOT PERFORMED ______ 14-1091 JBWC STM SS VALVE LOCKS ON, OPEN COMMAND WSSA 111 LOCKOUT ON AND GN2 PRESSURE TO STM NTD CLOSED ACTUATORS. 232 NTD *SCC NOT PERFORMED ______ 378 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING DO NOT BEGIN SS TANK/MLP LINE FILL IF ESP OR TRANSPORTER OPERATIONS IN PROGRESS AT FLAME HOLES. 14-1092 *PSE *SCC CLEARS HAVE BEEN ESTABLISHED. NET YOU HAVE SAFETY CONCURRENCE TO 105 BEGIN SOUND SUPPRESSION TANK FILL. *SCC NTD 232 NOT PERFORMED ______ 14-1093 NTD STM VERIFY SS CNTL LOGIC OVERRIDES WSSA 232 PRE-LO AND POST-LO INDICATORS STM JBWC OFF. 111 NOT PERFORMED ______ 14-1094 NTD STM FILL MLP SS LINES AND TANK PER WSSA 232 OMI M3189.001. REPLENISH AS SU72369 STM JBWC REQUIRED TO MAINTAIN WATER LEVEL 111 (2H15M). NOT PERFORMED ______ NOTE PERFORM SRB IGNITER HEATER ACTIVATION JUST PRIOR TO L-18H00M IF AMBIENT CONTROL TEMPERATURE IS LESS THAN 55 DEG F, OR FORECAST TO DROP BELOW 55 DEG F BEFORE T-08H00M. IF CONTROL TEMPERATURE DROPS BELOW 55 DEG F THEN THE IGNITER HEATERS ARE TO BE ACTIVATED IMMEDIATELY. SRB IGNITER HEATER ACTIVATION ----------------------------- NOT PERFORMED ______ 14-1095 -11H00M NTD TBC PERFORM SRB IGNITER HEATER POWER SU72469 (HOLDING) 232 APPLICATION. TBC CPWR 136 379 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CAUTION AT NO TIME ARE IGNITER HEATER CURRENTS TO EXCEED 4.9 AMPS. RSRM IGNITER TEMPERATURE SENSOR SHALL NOT EXCEED 125 DEG F. 14-1096 CPWR CURSOR CNTL (SDC01) SRB OPTIONS JOINT HEATERS XMIT CURSOR KEY - PRESS CRT VERIFY DISPLAY SKELETON BDE11 DISPLAYED 14-1097 CPWR CURSOR CNTL (BDE11) AUTO SEQ - IGN XMIT CURSOR KEY - PRESS 14-1098 CPWR CRT (BDE11) VERIFY LH/RH IGN HEATER POWER ON LH/RH IGN HEATER AUTO SEQ ACT OMRSD S00FA0.620-1R OMRSD S00FA0.960 NOTE PROGRAM BWE11 MUST REMAIN ACTIVE FROM L-18 HRS THROUGH T-0. 14-1099 CPWR TBC SRB IGNITER HEATER POWER SU72469 136 APPLICATION COMPLETE. TBC NTD 232 SRB IGNITER HEATER ACTIVATION COMPLETE -------------------------------------- 380 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1100 OTC *PAD PERFORM ORBITER OPERATION SU72396 132 SUPPORT SETUP 1 - MPS/SSME MLP *PAD PQCG PATCH RACK - DISTRIBUTOR PANEL INTEGRITY VERIFICATIONS. 14-1101 PQCG *PAD ORBITER OPERATIONS SUPPORT SU72396 *PAD OTC SETUP 1 - MPS/SSME MLP PATCH 132 RACK - DISTRIBUTOR PANEL INTEGRITY VERIFICATION COMPLETE. INITIATE BDA/PAD BUS SERVICE AND -------------------------------- TERMINATE POV'S TO PAD ---------------------- 14-1102 -11H00M NTD STM PROVIDE DEDICATED BUS SERVICE SU72432 (HOLDING) 232 FROM LAUNCH PAD TO BDA ROADBLOCK STM JSTC AT _____ ON L-1 DAY. 111 JSTC WGSA 114 14-1103 NTD *SEC TERMINATE P.O.V. TRAVEL TO SEC 232 PAD, AT _____ ON L-1 DAY. SU72434 (PER DAILY SCHEDULE) 14-1104 NTD *SEC TERMINATE POV TRAVEL TO SEC 232 NON-LAUNCH PAD AT _____ ON SU72434 L-1 DAY (PER SCHEDULE). 381 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TERMINATE TOUR BUS ROUTE TO PAD ------------------------------- NOTE PERFORM NEXT TWO STEPS 24 HOURS PRIOR TO LAUNCH OR AS DIRECTED BY NTD. 14-1105 NTD STM TERMINATE TOUR BUSES ROUTE SEC 232 PAST PAD-___ VIA NORTH BEACH AND SU72443 STM JSTC PAD-___ ACCESS ROAD. 111 JSTC *SEC 114 14-1106 *SEC JSTC TOUR BUS ROUTE TO PAD-___ SEC 114 TERMINATED. JSTC STM 111 STM NTD 232 14-1107 STM JSTC VERIFY PARKING LOT IN FRONT OF RGR 111 COMPLEX J ROPED OFF FOR RED CREW SU72412 JSTC WCRG PARKING. 114 382 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MILA/GSFC/JSC INTERFACE TEST ---------------------------- NOTE MILA WILL SUPPORT JSC WITH DATA AND COMMAND CAPABILITIES THRU LOS. MILA TELEMETRY COMSEC UNIT LOADING MUST BE COMPLETED PRIOR TO PERFORMANCE OF MILA/JSC INTERFACE TEST. 14-1108 -11H00M NTD *FLT CONFIGURE FOR JSC COMMANDING SU72384 (HOLDING) 232 *MIL AND CONDUCT MILA/GSFC/JSC INTERFACE TEST. (2 HR) OIS COMM CHECK WITH JSC ----------------------- NOTE PERFORM NEXT STEP ONE HOUR AFTER MILA/GSFC/JSC I/F TEST BEGINS. 14-1109 -11H00M NTD STM PERFORM COMM CHECKS (TONE/VOICE) COMM (HOLDING) 232 *MIL WITH JSC ON OIS CH 211 (UHF), SU72385 STM GYCC 212 (A/G 1) AND 213 (A/G 2). 111 (1 HOUR) GYCC GOIS 117 GYCL MILA/GSFC/JSC I/F TEST COMPLETE ------------------------------- 14-1110 -11H00M *FLT NTD MILA/GSFC/JSC INTERFACE TEST (HOLDING) *MIL COMPLETE. 232 383 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OIS COMM CK WITH JSC COMPLETE ----------------------------- 14-1111 -11H00M GOIS GYCC COMM CHECKS WITH JSC ON OIS COMM (HOLDING) GYCL CH 211 (UHF), 212 (A/G1) 117 AND 213 (A/G2) COMPLETE. GYCC STM 111 STM NTD 232 *MIL 14-1112 OTC CMQC VERIFY ORBITER PRE-OPERATION 132 SETUPS 13, 15 AND 17 COMPLETE. PREPS FOR COMM SYS ACTIVATION ----------------------------- NOTE PERFORM NEXT STEP IF C & T STATION NO. 1 (BAY 1/2) IS SUPPORTING LAUNCH COUNTDOWN. 14-1113 RCRT OTC OPERATION SUPPORT SETUP 12 AND SU72388 132 25 OF V3528.001 C & T STATION INITIALIZATION (PAD OPTION) COMPLETE. NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF C & T STATION NO. 2 (BAY 3) IS SUPPORTING LAUNCH COUNTDOWN. 14-1114 RCRT OTC OPERATION SUPPORT SETUPS 12 AND 25 132 OF V3528.002 C & T STATION INITIALIZATION (PAD OPTION) COMPLETE. NOT PERFORMED ______ 14-1115 OTC RCRT VERIFY COMSEC LOAD VERIFICATION PER 132 V3528.001/V3528.002 COMPLETE. 384 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- COMM SWITCHLIST CONFIGURATION ----------------------------- 14-1116 OTC CCSE PERFORM COMM SWITCHLIST SU72398 132 CDR CONFIGURATION PER OMI V1117. (1 HR) RT OMI LOG NO.__________ COMM SWITCH CONFIG COMPLETE --------------------------- 14-1117 -11H00M CCSE OTC COMM SWITCHLIST CONFIGURATION (HOLDING) 132 COMPLETE. NOTE PERFORM NEXT TWO STEPS IF EDO PALLET IS INSTALLED AND EDO TANKS ARE NOT AT FLIGHT PRESSURE. 14-1118 OTC CFCP PERFORM EDO TANK HEATER ACTIVATION 132 AND PRESSURIZATION PER OMI V1040.002. (1 HR) NOT PERFORMED ______ 14-1119 CFCP OTC EDO TANK HEATER ACTIVATION AND 132 PRESSURIZATION COMPLETE. NOT PERFORMED ______ L-24 HOUR WEATHER UPDATE - -------------------------- TEMPERATURE PREDICTION ---------------------- NOTE NEXT TWO STEPS TO BE PERFORMED AT APPROXIMATELY L-24 HOURS. 14-1120 NTD STM REQUEST CURRENT FORECAST FOR (HIGH 232 AND LOW) TEMPERATURES FOR DURATION STM JBDY OF COUNTDOWN. 111 JBDY *WEA 385 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1121 *WEA JBDY TEMPERATURE PREDICTION (AT LAUNCH JBDY STM PAD) REMAINDER OF LCD. ADVISE 111 ALL SYSTEMS. STM NTD 232 FORECAST TIME__________ NTD OTC TBC HIGH TEMP______DEG F WILL OCCUR STM AT ______Z. *SCC PTC LOW TEMP ______DEG F WILL OCCUR AT ______Z. L-1 DAY FLIGHT CREW WX BRIEFING ------------------------------- NOTE NEXT STEP TO BE PERFORMED AT _____ ON L-1 DAY. WEATHER BRIEFING AUDIO TO BE ON OIS CH 231. 14-1122 -11H00M *FLT NTD IMPLEMENT TELEVISED WEATHER COMM (HOLDING) 232 BRIEFING AND DISPLAY TO SU72323 NTD STM FOLLOWING LOCATIONS AT _____ STM GYCC ON L-1 DAY. (TIME TO BE 111 PROVIDED BY JSC REP, 7-4792) 138 JYVO GYCC GYVW PTP GYVO 1. FLIGHT CREW QUARTERS, O&C ROOM 3267, MONITORS 2033 & 2034. (CIRCUIT NO.'S 6TVM2080 AND 6TVM2087) 2. ER/ROCC FORECAST FACILITY ROOM 146. (CIRCUIT NO.'S EITHER 1TVC2079 OR 1TVC2083) 3. LCC 1/3 OSR. (SW1 INPUT 187 TO OUTPUT 383) 14-1123 STM JYVO VERIFY JSC WX BRIEFING FEED COMM 138 ON OTV SWITCHER SOURCE 187. 14-1124 GYVO GYCC VIDEO FOR WX BRIEFING IN CREW COMM GYVW QUARTERS AND TO ER READY. PTP 386 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1125 JYVO GYCC VIDEO FOR WEATHER BRIEFING TO COMM PTP LCC 1/3 OSR READY. 14-1126 GYCC STM VIDEO SYSTEM READY FOR FLIGHT COMM 111 CREW WX BRIEFING. STM NTD 232 NTD *FLT LD 14-1127 *FLT NTD WEATHER BRIEFING COMPLETE. COMM 232 SUPPORT RELEASED. NTD STM STM JYVO 138 111 GYCC GYCC GYVW PTP GYVO 387 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- L-1 DAY LD WX BRIEFING --------------------- 14-1128 -11H00M TBC CTIF CONDUCT L-1 DAY ET ICING (HOLDING) 136 PREDICTIONS BRIEFING WITH LAUNCH DIRECTOR PER OMI S6444 ET PRE-OPERATION SETUP 1. OMRSD S00FA0.900 14-1129 TBC CTIF PERFORM PRE-LAUNCH WALKDOWN PER SU72391 136 OMI S6444 PRE-OPERATION SETUP 2, RECORD DISCREPANCIES IN APPENDIX K. ESSENTIAL PERSONNEL FOR ICE/DEBRIS TEAM PRE-LAUNCH WALKDOWN: NASA SFOC ET MECH ENGR 1 NASA-KSC ET ENGR 4* USA-ET ENGR 2* PAD OPS 1* SFOC QC 1* LM-LSS 1* BNA-LSS 1* USBI-LSS 1* THIOKOL-LSS 1* * OPTIONAL OMRS S00U00.030-1 CONFIG EQUIPMENT (JFIR) ----------------------- 14-1130 -11H00M JSTC JFIR START FINAL WALKDOWN/SURVEY FIRE (HOLDING) 114 OF RSS, FSS, MLP AND PAD APRON. REMOVE FIRE EXTINGUISHERS. (1 HR) 14-1131 JSTC JFIR PLACE TWO FIRE EXTINGUISHERS FIRE 114 IN EACH FSS ELEVATOR. (1 HR) SU72360 388 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- REMOVE ZERO LEVEL FIRE ALARM STATIONS ------------------------------------- 14-1132 -11H00M JSTC JFIR REMOVE MLP ZERO LEVEL FIRE FA (HOLDING) 114 ALARM PULL STATIONS AND ALARM SU72361 BELL GONG. (1 HR) REMOVE OIS UNITS - PAD SURFACE ------------------------------ NOTE UCOM/GSS TECHS MEET AT BASE OF FSS ELEVATOR. 14-1133 -11H00M STM GYCC UCOM REMOVE FOLLOWING OIS COMM (HOLDING) 111 JBPN UNITS FROM LAUNCH PAD IN USE. PNSA GYCC JYCD SECURE CABLE ENDS. GSS SECURE SU72413 117 DISCONNECTED PURGE LINES IN PLACE WITH BLAST TAPE. (COMPLETE BY -08H00M) 1. PAD A SURFACE STA 116-0A LOX TOWER 75 FT LEVEL N.W. CORNER OF STAIRWELL 117-73 LH2 TOWER 75 FT LEVEL N.W. CORNER OF STAIRWELL 116-73 PNEUMATIC TOWER TOP LEVEL 116-45 EAST PAD SLOPE AT PEDESTAL LH2 LINES 118-72 EAST SIDE 119-69 INDUSTRIAL WATER PLATFORM UCOM T:______ SS1 GSS T:______ SS1 NOT PERFORMED ______ SS1 389 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1133 2. PAD B SURFACE CON'T STA 121-48 LOX TOWER 123-09 PNEUMATIC TOWER 122-28 LH2 TOWER 121-50 EAST PAD SLOPE AT LH2 LINES 123-4A EAST SIDE 123-48 INDUSTRIAL WATER PLATFORM UCOM T:______ SS2 GSS T:______ SS2 NOT PERFORMED ______ SS2 ESSENTIAL PERSONNEL ------------------- UCOM GSS ---- --- TECH 6 2 QA 1 390 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- REMOVE PORTABLE OIS UNITS - RSS ------------------------------- 130 FT LEVEL ------------ NOTE DO NOT PERFORM NEXT STEP IF PORTABLE OIS UNITS ADJACENT TO AFT FUSELAGE 50-2 AND/OR 50-1 DOOR PREVIOUSLY REMOVED FROM RSS 130 FT LEVEL. UCOM/GSS TECHS MEET AT BASE OF FSS ELEVATOR. 14-1134 -11H00M STM GYCC UCOM REMOVE PORTABLE OIS UNITS COMM (HOLDING) 111 JBPN ADJACENT TO AFT FUSELAGE 50-2 PNSA GYCC JYCD AND/OR 50-1 DOOR FROM RSS SU72303 117 130 FT LEVEL. (30 MIN) GSS REMOVE PURGE FLEXHOSE ON RSS 130 FT LEVEL. UCOM T:______ GSS T:______ NOT PERFORMED ______ 391 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OIS UNIT REMOVAL STATUS ----------------------- NOTE DO NOT PERFORM NEXT TWO STEPS IF OIS UNITS ADJACENT TO AFT FUSELAGE 50-2 AND/OR 50-1 DOOR WERE PREVIOUSLY REMOVED FROM RSS 130 FT LEVEL. 14-1135 -11H00M JYCD GYCC PORTABLE OIS UNITS ADJACENT TO COMM (HOLDING) 117 AFT FUSELAGE 50-2 AND/OR 50-1 SU72303 GYCC STM DOORS HAVE BEEN REMOVED FROM 111 RSS 130 FT LEVEL AND DISCONNECTED CABLES REMOVED OR SECURED. NOT PERFORMED ______ 14-1136 JBPN STM PURGE FLEXHOSE DISCONNECTED FOR PNSA 111 REMOVAL OF OIS UNITS FROM RSS 130 FT LEVEL HAS BEEN REMOVED. NOT PERFORMED ______ GOX VENT ARM SYSTEM INITIAL --------------------------- ACTIVATION COMPLETE ------------------- 14-1137 -11H00M CMEC TBC GOX VENT ARM SYSTEM INITIAL (HOLDING) 136 ACTIVATION PER G2158 COMPLETE. 14-1138 TBC *PAD INSPECT ET TPS AT +Y/-Y GOX 136 VENT SEAL FOOTPRINT PER OMI T6446. *PAD PQCL VERIFY NO VISIBLE DAMAGE PER T6446. 14-1139 PQCL *PAD INSPECTION OF ET TPS AT +Y/-Y SU72348 *PAD TBC GOX VENT SEAL FOOTPRINT COMPLETE 136 PER T6446. 392 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LAUNCH PAD TOURS ---------------- NOTE PERFORM NEXT STEP AT L-24 HOURS. TOURS MAY BE PERMITTED ABOVE PAD SLOPE AFTER THIS TIME AT THE DISCRETION OF THE NTD. 14-1140 NTD OIC DISCONTINUE ALL TOURS ABOVE PAD SU72408 | NET SLOPE. NTD MAY APPROVE EXCEPTIONS | 110 AS DIRECTED BY LAUNCH DIRECTOR. | 232 OTC OTC *PAD 132 CLEAR FOR COMM ACTIVATION ------------------------- WARNING HAZARDOUS STEPS FOLLOW DUE TO RF RADIATION. 14-1141 OTC CCSE READY TO PROCEED WITH COMM 132 *PAD ACTIVATION PER OMI V1117. 232 NTD NTD *SCC *SCC *PSE NET 105 14-1142 OTC NTD CLEAR ALL PERSONNEL 5 FT FROM SU72400 232 S-BAND AND UHF ANTENNAS. POST SU72424 NTD *SCC SAFETY SIGN ON 193 FT LEVEL. *SCC *PSE NET 105 14-1143 NTD ATTENTION ON PAD ___: PA ALL PERSONNEL STAND 5 FT CLEAR OF ORBITER COMM SYSTEM ANTENNAS FOR HAZARDOUS RF RADIATION. 393 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1144 *PSE *SCC ALL PERSONNEL CLEARED AND SAFETY NET SIGN POSTED. YOU HAVE SAFETY 105 CONCURRENCE FOR COMM ACTIVATION. *SCC NTD 232 NTD OTC VERIFY FLIGHT CONTROL TEAM -------------------------- STATUS AND DATA LINKS --------------------- 14-1145 -11H00M NTD *FLT VERIFY FLIGHT CONTROL TEAM ON SU72387 (HOLDING) 232 STATION. 14-1146 NTD LPS VERIFY 128 KB PCMMU DATA ON 232 6TVM1730/6TVM4647 TO MILA. 14-1147 -11H00M NTD *FLT VERIFY HARDLINE DATA BEING (HOLDING) 232 RECEIVED AT JSC. ORB COMM SYSTEM ACTIVATION (MCCH) --------------------------------- 14-1148 -11H00M NTD *FLT VERIFY READY TO SUPPORT COMM COMM (HOLDING) 232 *MIL ACTIVATION ON OIS CH 214. STM (V1117) STM GYCC 111 GYCC GOIS 117 GYCL 394 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING NEXT STEP HAZARDOUS DUE TO OPEN LOOP RF RADIATION. NOTE IF NSP 2 DATA IS NOT BEING POLLED, CCSE WILL REQUEST CDPS TO PERFORM I/O RESET. 14-1149 -11H00M NTD OTC PERFORM COMM SYSTEM ACTIVATION SU72401 (HOLDING) 232 LPS FOR MCCH OPTION PER OMI V1117 JRPS ON OIS CH 214. (1 1/2 HR) OTC CCSE 132 RCRE CDR RT OMI LOG NO.____________ PLT MS2 MS1 14-1150 OTC CCSE REPORT WHEN ACTIVATION REQUIRING 132 MULTIPLE CREW PERSONNEL COMPLETE. 14-1151 CCSE OTC ASTRO COMM - OIS INTERFACE PNL 132 POWER SW - ON ON LITE ON ICOM-A SW - ACTIVE ACTIVE LITE ON AND READY LITE ON ICOM-B SW - ACTIVE ACTIVE LITE ON AND READY LITE ON A/G 1 SW - ACTIVE ACTIVE LITE ON AND READY LITE ON A/G 2 SW - ACTIVE ACTIVE LITE ON AND READY LITE ON UHF SW - MONITOR MONITOR LITE ON AND READY LITE ON 395 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1152 CCSE OTC ASTRO COMM - OIS INTERFACE PNL 132 A/G 1 SW - ACTIVE VERIFY A/G 1 ACTIVE LITE ON A/G 2 SW - MONITOR VERIFY A/G 2 MONITOR LITE ON A/A SW - MONITOR VERIFY A/A MONITOR LITE ON ICOM A SW - OFF VERIFY ICOM A ACTIVE AND MONITOR LITES OFF ICOM B SW - OFF VERIFY ICOM B ACTIVE AND MONITOR LITES OFF 14-1153 CCSE OTC PERFORM A/G VOICE CHECKS WITH SU72403 132 ASP (OR SCO) (USING A/G 1, A/G 2, OTC NTD ICOM A, ICOM B AND UHF AUDIO PB'S 232 INDIVIDUALLY ON CONSOLE AB5). VERIFY D/L VOICE ON A/G 1, A/G 2, UHF, ICOM A AND ICOM B. NOTE NOTIFICATION IN NEXT STEP WILL ALLOW ACCESS TO BEGIN FCE TIME CRITICAL STOW. 14-1154 CCSE OTC COMM ACTIVATION REQUIRING MULTIPLE 132 CREW PERSONNEL COMPLETE. 396 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORB COMM SYS ACT - COMPLETE --------------------------- 14-1155 -11H00M CCSE OTC COMM SYSTEM ACTIVATION PER V1117 SU72401 (HOLDING) 132 COMPLETE. OTC NTD 232 | IUS OCV CHECKS | -------------- | | NOTE | | PERFORM NEXT STEP FOR | IUS MISSION (STS-93). | | PERFORM NEXT STEP IF | REQUIRED PER ICTC | DIRECTION APPROXIMATELY | 36 HOURS PRIOR TO LAUNCH. | | 14-1156 PTC NTD READY TO PROCEED WITH OCV CHECKS | 232 PER S0007VL4 (SEQ 85). CMQC AND | NTD OTC CDR SUPPORT WILL BE REQUIRED ON | OIS CH 144. REPORT COMPLETION. | | NOT PERFORMED ______| 397 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE FOLLOWING OMRS' WILL NOT BE PERFORMED FOR RECYCLE. OMRSD S00FA0.372-C OMRSD S00FA0.372-E OMRSD S00FA0.372-F GPS EARLY ACTIVATION -------------------- NOTE PERFORM NEXT FOUR STEPS IF EARLY ACTIVATION IS REQUIRED. (OV-104,103,105 ONLY) 14-1157 CNSE CDR PANEL O15 ROW C MN B UTILITY POWER F1/MO13Q/CB - CLOSED NOT PERFORMED ______ 14-1158 CNSE CDR PANEL MO13Q DC UTILITY POWER SW - ON NOT PERFORMED ______ 14-1159 CNSE CDR PANEL A13 GPS PREAMPL LC SW - MN A UC SW - MN C NOT PERFORMED ______ 398 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF GPS/SIGI EARLY ACTIVATION IS REQUIRED. 14-1160 CNSE CDR PANEL A13 GPS GPS/SIGI POWER SW - ON GPS/SIGI ENCRYPT - NORMAL GMT__________ NOT PERFORMED ______ COMM SYS RF RADIATION COMPLETE ------------------------------ NOTE DO NOT PERFORM NEXT FOUR STEPS UNTIL COMM ACTIVATION COMPLETE. 14-1161 -11H00M OTC CCSE CRT (VAA19) (HOLDING) 132 VERIFY PM T/R - RCV ONLY FM OI XMTR - OFF 14-1162 CCSE OTC RF RADIATION HAS TERMINATED. 132 *PAD READY TO REMOVE ANTENNA COUPLERS. OTC NTD AREA OPEN FOR CONTROLLED WORK. 232 NTD *SCC *SCC *PSE NET 105 14-1163 *PSE *SCC RF RADIATION CONTROL AREA OPEN SU72424 NET FOR CONTROLLED WORK. 105 *SCC NTD 232 NTD OTC OTC CCSE 132 399 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE HAZARDOUS STEPS FOR COMM SYS RF RADIATION COMPLETE. COMM ANTENNA COUPLER REMOVAL ---------------------------- 14-1164 -11H00M OTC *PAD REMOVE COMM ANTENNA COUPLERS SU72444 (HOLDING) 132 PER OMI V1117 - COMM ANTENNA COUPLER REMOVAL (TASK 14) (1 HR). RT OMI LOG NO.__________ COMM ANTENNA COUPLER REMOVAL ---------------------------- COMPLETE -------- 14-1165 -11H00M *PAD OTC COMM ANTENNA COUPLER REMOVAL PER (HOLDING) 132 V1117 COMPLETE. 14-1166 OTC *PAD PERFORM ORBITER OPERATION SU72441 132 SUPPORT SETUP 4 - GTOE HEADSET EQUIPMENT REMOVAL. 14-1167 *PAD OTC ORBITER OPERATION SUPPORT SETUP 4 - 132 GTOE HEADSET EQUIPMENT REMOVAL COMPLETE. 14-1168 OTC *PAD PERFORM ORBITER OPERATION SU72292 132 SUPPORT SETUP 12 PART A - CREW COMPARTMENT FINAL CLEANING AND INSPECTION. (2 HR) 400 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE NEXT STEP SHOULD BE PERFORMED AT LEAST TWO HOURS PRIOR TO RSS MOVE AND MUST BE VERIFIED COMPLETE PRIOR TO ROTATION. THE FOLLOWING ITEMS ARE NOT A CONSTRAINT TO RSS MOVE AND WILL BE CLOSED OUT DURING SIDE HATCH CABIN AND ENVIRONMENTAL CHAMBER CLOSEOUT (S0007V1, OSSU 20). 1. RAIN GUTTER ABOVE HATCH. 2. SIDE HATCH WINDOW COVER. 3. HATCH SEAL PROTECTOR. 14-1169 OTC *PAD BEGIN EXTERNAL TIRR LOG CLOSEOUT. SU72465 132 QW:_____ 14-1170 OTC CMQC REVIEW ORBITER EXTERNAL TIRR LOG 132 FOR ANY OPEN ITEMS AND SRB TIRR CMQC PQCG LOG FOR ANY OPEN FORWARD SKIRT ITEMS. REPORT OPEN ITEMS TO OTC. 14-1171 *PAD OTC ORBITER OPERATION SUPPORT SETUP SU72292 132 12 PART A - CREW COMPARTMENT FINAL CLEANING AND INSPECTION COMPLETE. 401 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SOFT WINDOW COVER REMOVAL ------------------------- 14-1172 -11H00M OTC *PAD PERFORM ORBITER OPERATION SU72450 (HOLDING) 132 SUPPORT SETUP 9 - WINDOW COVER REMOVAL FOR FLIGHT. (2 HR) WINDOW COVER REMOVAL COMPLETE ----------------------------- 14-1173 *PAD OTC ORBITER OPERATION SUPPORT SETUP SU72450 132 9 - WINDOW COVER REMOVAL FOR FLIGHT COMPLETE. NOTE PERFORM NEXT TWO STEPS IF DOCK SEALS WERE REINFLATED AFTER TPS INSPECTION DUE TO WINDS. DEFLATE DOCK SEALS AND INSPECT ------------------------------ 14-1174 *PAD OTC DEFLATE DOCK SEALS PER OMI V1122 132 "DOCK SEAL INFLATION/DEFLATION, OTC PPVM OPTION C". REPORT COMPLETION. RT OMI LOG NO.__________ NOT PERFORMED ______ 402 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1175 OTC PQCG VISUALLY INSPECT PCR SEAL/TPS 132 INTERFACE ORB AREA APPROXIMATELY 1 FOOT INBOARD AND OUTBOARD FROM CENTER LINE (COORDINATE) OF SEAL CONTACT; ACROSS UPPER FORWARD FUSELAGE L/H TO R/H SIDE FROM Z=402.75 AT X=564.5; ACROSS UPPER AFT FUSELAGE L/H TO R/H SIDE FROM Z=402.75 AT X=1323; ALONG MID FUSELAGE L/H AND R/H SIDES FROM X=564.5 TO X=1323 AT Z=402.75. DOCUMENT EVIDENCE OF BROKEN TILES OR APPARENT TILE DEGRADATION. INSPECT FI OML SURFACE AND VISIBLE EDGES FOR CUTS, TEARS, FRAYED AREAS, AND BROKEN QUILTING STITCHES IN EXCESS OF SPECIFICATION ALLOWABLES. INSPECT CERAMIC COATING FOR FLAKING, MISSING COATING AND FOR EVIDENCE OF CONTAMINATION AND/OR DISCOLORATION. INSPECT FOR EVIDENCE OF BLANKET JOINT GAPS OPENING OR OUT OF TOLERANCE STEPS DEVELOPING. REPORT COMPLETE. DOCUMENT EVIDENCE OF UNACCEPTABLE CRACKED COATING, BUTT JOINT SEPARATION, ABNORMAL DISCOLORATION EMBRITTLEMENT, TEARS, CUTS OR RIPS IN FRSI MATERIAL. UPPER FORWARD FUSELAGE TQWN:___ UPPER AFT FUSELAGE TQWN:___ R/H MID FUSELAGE TQWN:___ L/H MID FUSELAGE TQWN:___ OMRSD V09AH0.090 NOT PERFORMED ______ 403 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1176 QMTG *PAD MLP INTERIOR SECURING PER SU72389 *PAD OTC OPERATION SUPPORT SETUP 29 132 COMPLETE. PAYLOAD POWER SWITCHOVER AND IVT'S ---------------------------------- NOTE PERFORM NEXT TWO STEPS IF MIDDECK IVT'S ARE REQUIRED. THE NEXT STEP CONTAINS ACTIVITIES THAT ARE TIME CRITICAL. 14-1177 PTC NTD FOLLOWING EXPERIMENTS WILL BE 232 INSTALLED AT REFERENCED L-TIMES. AFTER INSTALLATION, POWER SWITCHOVER AND IVT'S WILL BE PERFORMED PER S0007 VL4 (SEQ 53). LOCKER INSTALLATION EXPERIMENT LOCATION L-TIME ---------- -------- ------------ __________ ________ ____________ __________ ________ ____________ __________ ________ ____________ __________ ________ ____________ __________ ________ ____________ __________ ________ ____________ __________ ________ ____________ __________ ________ ____________ __________ ________ ____________ __________ ________ ____________ __________ ________ ____________ 404 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1177 __________ ________ ____________ CON'T __________ ________ ____________ NOT PERFORMED ______ 14-1178 PTC NTD ALL MIDDECK EXPERIMENT IVT'S COMPLETE. 232 NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP FOR SCRUB TURNAROUND IF SYSTEM HAS REMAINED CONFIGURED. 14-1179 STM JBFX CONFIGURE PAD WASHDOWN SYSTEM WSSA 111 FOR SEQUENCER PANEL ARMING PER SU72496 OMI M3190. NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF EARLY HOOKUP OF VACUUM VENT ASSY REQUIRED TO ALLEVIATE ACCESS PROBLEMS DURING LATE STOW. 14-1180 OTC CECL PERFORM VACUUM VENT QD/FLEXHOSE SU72476 132 ASSY CONNECT IN WCS PER ORBITER OPERATION SUPPORT SETUP 5. NOT PERFORMED ______ NOTE NEXT STEP WILL CLEAR ALL FD'S PREVIOUSLY ASSIGNED TO THE SCRS PRINTER PLOTTER SUB-SYSTEMS 1 AND 2. 14-1181 LPS C1MC $TERM AND $CLAI PP1 AND PP2 127 C2MC SUBSYSTEMS. 405 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FCE TIME CRITICAL STOWAGE ------------------------- 14-1182 -11H00M OTC OOCS PERFORM INSTALLATION OF FCE TIME SU72477 (HOLDING) 132 CRITICAL ITEMS PER OMI V5097.003 OR PER FCS TPS. 14-1183 -11H00M CTIF TBC PRE-OPERATION SETUP 2 OF S6444 SU72391 (HOLDING) 136 COMPLETE. DISCREPANCIES RECORDED TBC NTD IN APPENDIX K. 232 OMRSD S00U00.030-1 ORBITER AIRLOCK CLOSEOUT COMPLETE --------------------------------- (MVAK CONTINGENCY) ------------------ NOTE PERFORM NEXT FOUR STEPS IF MVAK OPERATIONS SCHEDULED. 14-1184 NTD OTC PERFORM OPERATION SUPPORT SETUP 22 - 232 ORBITER AIRLOCK CLOSEOUT. OTC *PAD 132 NOT PERFORMED ______ 14-1185 *PAD OTC OPERATION SUPPORT SETUP 22 - ORBITER 132 AIRLOCK CLOSEOUT COMPLETE. OTC NTD 232 NOT PERFORMED ______ 406 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP FOR OV-102 | AND OV-104 ONLY. 14-1186 OTC *PAD PERFORM A70-0558 MIDDECK PLATFORM 132 REMOVAL PER: JC V66-90006 - PLATFORM ACCESS SET, A70-0558 PARTIAL MIDDECK, CREW MODULE, VERTICAL, REMOVAL (2 HR) NOT PERFORMED ______ NOTE PERFORM NEXT STEP FOR OV-103 AND OV-105 ONLY. 14-1187 OTC *PAD PERFORM Z70-0558 MIDDECK PLATFORM 132 REMOVAL PER: JC V66-50009 - INSTL/REM AIRLOCK OUT VERTICAL ACCESS SET- CREW MODULE (2 HR) NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF REQUIRED AFTER MVAK OPERATIONS AND/OR FCE TIME CRITICAL STOW (REF S0007 BAR CHART). 14-1188 OTC *PAD PERFORM ORBITER OPERATION SU72562 132 SUPPORT SETUP 12 PART B - CREW SU72458 *PAD OMTO MODULE FINAL INSPECTION. OQCO ONQC NOT PERFORMED ______ 407 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORB HYD WALKDOWN ---------------- 14-1189 -11H00M OTC *PAD PERFORM ORBITER OPERATION SU72407 | (HOLDING) 132 SUPPORT SETUP 27 - HYDRAULIC PRE-LAUNCH WALKDOWN. 14-1190 OTC *PAD ASCENT SWITCHLIST WILL BEGIN SU72460 132 CDR IN APPROXIMATELY 30 MIN. PERFORM ORBITER OPERATION SUPPORT SETUP 16 - REMOVAL AND IDENTIFICATION OF REMOVED SWITCHGUARDS. ECLSS CONFIG FOR ASCENT SWITCHLIST ---------------------------------- CAUTION IF NH3 CONTROLLER SWITCH (A OR B) IS INADVERTENTLY PLACED IN SEC/ON POSITION, NH3 FLIGHT LOAD WILL BE LOST. 14-1191 -11H00M CECL OTC PANEL L1 SU72436 (HOLDING) 132 NH3 CONTROLLER OTC CDR A SW - OFF L1A02S042 B SW - PRI/GPC L1A02S04 FLASH EVAP CONTROLLER PRI A SW - GPC L1A02S031 PRI B SW - OFF L1A02S032 SEC L1A02S033 GPC/OFF/ON SW - OFF NOTE PERFORM NEXT STEP IF DUAL MODE COOLING WILL BE REQUIRED THIS LAUNCH. 14-1192 OTC CECL CONFIGURE FREON LOOPS TO RAD FLOW 132 PER ORBITER OPERATION SUPPORT SETUP 8. REPORT COMPLETION. NOT PERFORMED ______ 408 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- EDO O2 TANK HTR SNSR CONFIG --------------------------- CAUTION EDO O2 TANK HEATER PRESSURIZATION MUST BE COMPLETE PRIOR TO PERFORMANCE OF NEXT STEP. NOTE PERFORM NEXT STEP FOR EDO MISSIONS ONLY. 14-1193 OTC ASP PANEL A15 ROW H PALLET CRYO MNA TANK 6 (TANK 6/10 OV-104) O2 HTR SNSR 1 CB - OPEN MNB TANK 6 (TANK 6/10 OV-104) O2 HTR SNSR 2 CB - OPEN ROW I PALLET CRYO MNA TANK 7 (TANK 7/11 OV-104) O2 HTR SNSR 1 CB - OPEN MNB TANK 7 (TANK 7/11 OV-104) O2 HTR SNSR 2 CB - OPEN ROW J PALLET CRYO MNA TANK 8 (TANK 8/12 OV-104) O2 HTR SNSR 1 CB - OPEN MNB TANK 8 (TANK 8/12 OV-104) O2 HTR SNSR 2 CB - OPEN ROW K PALLET CRYO MNA TANK 9 (TANK 9/13 OV-104) O2 HTR SNSR 1 CB - OPEN MNB TANK 9 (TANK 9/13 OV-104) O2 HTR SNSR 2 CB - OPEN NOT PERFORMED ______ 409 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OMS/RCS CONFIG FOR ASCENT SWITCHLIST ------------------------------------ 14-1194 OTC COOS PERFORM OMS/RCS SWITCH 132 CONFIGURATION PER S0007VL4 (SEQ 40). (15 MIN) 14-1195 COOS OTC OMS/RCS SWITCH CONFIGURATION 132 COMPLETE. HYDRAULIC CONFIG FOR ASCENT SWITCHLIST -------------------------------------- 14-1196 -11H00M OTC CHYD PERFORM HYD SYS CONFIG FOR (HOLDING) 132 CDR SWITCHLIST. 14-1197 CHYD CDR PANEL L4 ROW O AC1 BLR HYD BYPASS 1B PH A CB - CLOSE HYD QTY 1 PH B CB - CLOSE BLR HYD BYPASS 3A PH C CB - CLOSE AC2 BLR HYD BYPASS 1A PH A CB - CLOSE HYD QTY 2 PH B CB - CLOSE BLR HYD BYPASS 2B PH C CB - CLOSE AC3 BLR HYD BYPASS 2A PH A CB - CLOSE HYD QTY 3 PH B CB - CLOSE BLR HYD BYPASS 3B PH C CB - CLOSE 410 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1198 CHYD PLT PANEL R2 APU/HYD HYD MAIN PUMP PRESS 1 SW - NORM 2 SW - NORM 3 SW - NORM HYD CIRC PUMP 1 SW - GPC (GUARDED) 2 SW - GPC (GUARDED) 3 SW - GPC (GUARDED) BOILER CNTLR HTR 1 SW - A 2 SW - A 3 SW - A BOILER PWR 1 SW - OFF 2 SW - OFF 3 SW - OFF BOILER N2 SUPPLY 1 SW - OFF 2 SW - OFF 3 SW - OFF 14-1199 CHYD PLT PANEL R4 HYDRAULICS BRAKE HEATER A SW - OFF B SW - OFF C SW - OFF 14-1200 CHYD ASP PANEL A12 HYDRAULIC HEATER RUDDER SPD BK A SW - AUTO B SW - OFF BODY FLAP A SW - AUTO B SW - OFF ELEVON A SW - AUTO B SW - OFF AFT FUSELAGE A SW - AUTO B SW - OFF HYD CIRC PUMP POWER 1 SW - MN A 2 SW - MN B 3 SW - MN C 411 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1201 CHYD ASP PANEL MA73C ROW F AC 1 OPS INST HYD ACTR PH C CB - CLOSE AC 2 OPS INST HYD ACTR PH C CB - CLOSE 14-1202 CHYD OTC HYDRAULIC SYSTEM CONFIGURATION 132 FOR SWITCH LIST COMPLETE. UNLOCK HATCH JETTISON "T" HANDLE BOX ------------------------------------ 14-1203 OTC *PAD PERFORM OPERATION SUPPORT SETUP SU72438 132 26 - UNLOCK HATCH JETTISON "T" HANDLE BOX (30 MIN). | IUS CALL TO STATION | ------------------- | | NOTE | | PERFORM NEXT STEP FOR | IUS/AXAF (STS-93). | | PERFORM NEXT STEP AT L-23 | HOURS. | | 14-1204 PTC NTD PERFORMING IUS CALL TO STATIONS | 232 AND PRE-LAUNCH CONFIGURATION PER | NTD OTC S0007VL4 (SEQ 78). | | NOT PERFORMED ______| 412 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRE-ASCENT SWITCHLIST FOR PAYLOADS ---------------------------------- | NOTE | | PERFORM THE PRE-ASCENT IUS/ | AXAF SWITCHLIST NO LATER | THAN L-22 HOURS. | 14-1205 NTD PTC PERFORM PRE-ASCENT SWITCHLIST SU72439 232 FOR PAYLOADS PER S0007VL4 (SEQ 79). NOT PERFORMED ______| | 14-1206 PTC NTD PRE-ASCENT SWITCHLIST COMPLETE. NOT PERFORMED ______| | IUS AFD PNL ASP SUPPORT | ----------------------- | | NOTE | | PERFORM NEXT STEP FOR IUS/ | AXAF (STS-93). | | PERFORM NEXT STEP AT L-21H30M. | | 14-1207 PTC OTC REQUEST ASP SUPPORT ON OIS CH 134 | 132 FOR IUS AFD PANEL PRESET FOR | MISSION PER S0007VL4 (SEQ 78). | | NOT PERFORMED ______| | IUS POWER ON PREPS AND POWER UP | ------------------------------- | | 14-1208 NTD PTC PERFORM IUS POWER ON PREPS AND | POWER IUS ON PER S0007VL4 (SEQ 78). | | PAYLOAD SSP/PRLA CONFIG FOR ASCENT S/L -------------------------------------- 14-1209 OTC CPLE PERFORM SSP/PRLA SWITCH 132 CONFIGURATION PER S0007VL4 (SEQ 58). 14-1210 CPLE OTC SSP/PRLA SWITCH CONFIGURATION 132 COMPLETE. 413 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MECH CONFIG FOR ASCENT SWITCHLIST --------------------------------- NOTE PERFORM NEXT FIVE STEPS PRIOR TO MCA CONFIGURE. 14-1211 -11H00M OTC CDR PERFORM MECH SYSTEM CONFIGURATION (HOLDING) 132 FOR ASCENT SWITCHLIST. 14-1212 OTC CDR PANEL O6 STAR TRACKER DOOR CONTROL SYS 1 SW - OFF SYS 2 SW - OFF POWER -Y SW - OFF -Z SW - OFF 14-1213 OTC CDR PANEL C3 AIR DATA PROBE STOW LEFT SW - INHIBIT RIGHT SW - INHIBIT AIR DATA PROBE LEFT SW - STOW RIGHT SW - STOW 14-1214 OTC CDR PANEL R13L PL BAY MECH PWR SYS 1 SW - OFF SYS 2 SW - OFF PL BAY DOOR SW - STOP PL BAY DOOR ENABLE/DISABLE SYS 1 SW - DISABLE SYS 2 SW - DISABLE 14-1215 OTC CDR PANEL R2 132 ET UMB DOOR MODE SW - GPC 414 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MCA CONFIG FOR ASCENT SWITCHLIST -------------------------------- 14-1216 OTC MS1 PANEL MA73C SU72436 132 ROW A MCA LOGIC MN A FWD 1 SW - ON MA73CS001 MID 1 SW - ON MA73CS002 MN B FWD 2 SW - ON MA73CS005 MID 1 SW - ON MA73CS006 MID 2 SW - ON MA73CS007 MN C FWD 3 SW - ON MA73CS011 MID 2 SW - ON MA73CS012 ROW B MCA LOGIC MN A AFT 1 SW - ON MA73CS004 MID 3 SW - ON MA73CS003 MN B AFT 2 SW - ON MA73CS010 MID 3 SW - ON MA73CS008 MID 4 SW - ON MA73CS009 MN C AFT 3 SW - ON MA73CS014 MID 4 SW - ON MA73CS013 ROW C MCA POWER AC1 3 PH FWD 1 CB - CLOSE MA73CC001 MID 1 CB - CLOSE MA73CC002 MCA POWER AC2 3 PH FWD 2 CB - CLOSE MA73CC005 MID 1 CB - CLOSE MA73CC006 MID 2 CB - CLOSE MA73CC007 MCA POWER AC3 3 PH FWD 3 CB - CLOSE MA73CC011 MID 2 CB - CLOSE MA73CC012 415 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1216 ROW D CON'T MCA POWER AC1 3 PH AFT 1 CB - CLOSE MA73CC004 MID 3 CB - CLOSE MA73CC003 MCA POWER AC2 3 PH AFT 2 CB - CLOSE MA73CC010 MID 3 CB - CLOSE MA73CC008 MID 4 CB - CLOSE MA73CC009 MCA POWER AC3 3 PH AFT 3 CB - CLOSE MA73CC014 MID 4 CB - CLOSE MA73CC013 NOTE NEXT STEP MUST BE COMPLETED PRIOR TO PERFORMING ASCENT SWITCHLIST. 14-1217 *PAD OTC OPERATION SUPPORT SETUP 26 - SU72438 132 UNLOCK HATCH JETTISON "T" HANDLE BOX COMPLETE. NOTE PERFORM NEXT STEP IF MVAK OPERATIONS SCHEDULED. (REF S0007 BAR CHART) 14-1218 OMTO *PAD ORBITER OPERATION SUPPORT SETUP 12 OQCO PART B - CREW MODULE FINAL INSPECTION *PAD OTC COMPLETE. 132 NOT PERFORMED ______ 14-1219 OOCS OTC FCE TIME CRITICAL STOWAGE SU72477 132 COMPLETE. OTC NTD 232 416 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ASCENT SWITCHLIST ----------------- NOTE ALL OTHER SCHEDULED OPERATIONS IN CREW MODULE ARE REQUIRED TO BE COMPLETED PRIOR TO START OF ASCENT SWITCHLIST. ANY EXCEPTIONS MUST BE APPROVED BY NTD. ASCENT SWITCHLIST (SEQ 76) IS DIVIDED INTO TWO SECTIONS. FIRST SECTION CONTAINS FLIGHT DECK PANELS AND C&W SETUPS. SECOND SECTION CONTAINS MIDDECK AND AFT FLIGHT DECK PANELS, AIRLOCK AND WASTE MANAGEMENT SYSTEM. FROM INITIATION OF ASCENT SWITCHLIST UNTIL COMPLETION OF FLIGHT CREW INGRESS OPERATIONS, ASP SHALL PERFORM SWITCH/CIRCUIT BREAKER ACTIONS IN CREW COMPARTMENT. 14-1220 -11H00M OTC ALL ALL ORBITER SYSTEMS ENGINEERS IN SU72463 (HOLDING) 132 FIRING ROOM VERIFY READY TO SUPPORT ASCENT SWITCHLIST. REPORT ANY KNOWN CHANGES IN CONFIGURATION. CCSE_____ CAPU_____ CNSE_____ CHYD_____ CAFM_____ CISL_____ CPLE_____ CEPD_____ CMPS_____ COFC_____ CECL_____ CGNC_____ CFCP_____ CDPS_____ COOS_____ CODS_____ CCME_____ CTPE_____ 417 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE IF NO KLES/DLES/CLES ON STATION, OTC SHALL NOTIFY PTC OF ANY SWITCH CONFIGURATION CHANGES. 14-1221 OTC PTC REQUEST KLES/DLES/CLES SUPPORT FOR 132 ASCENT FLIGHT DECK SWITCHLIST. 14-1222 OTC ALL SYSTEMS ENGINEERS MONITOR 132 1. OIS CH 161 FOR MIDDECK/AFT FLIGHT DECK/AIRLOCK/WMS SWITCHLIST. 2. OIS CH 131 FOR FLIGHT DECK C&W SETUPS SWITCHLIST. 3. ALL ORBITER/OTC TRAFFIC OTHER THAN SWITCHLIST ON OIS CH 132. 14-1223 OTC CDR STANDBY FOR ASCENT SWITCHLIST. 132 PLT MIDDECK/AFT FLIGHT DECK/AIRLOCK/ CMQC WMS WILL BE ON OIS CH 161. FLIGHT DECK/C&W SETUPS WILL BE ON OIS CH 131. ASCENT SWITCHLIST WILL BE PERFORMED PER S0007VL4 (SEQ 76). 14-1224 OTC ALL PERFORM ASCENT SWITCHLIST (SEQ 76). 132 ALL SYSTEMS ENGINEERS MONITOR SWITCHLIST CALLOUTS. (2 HRS) NOTE PERFORM NEXT STEP IF MIDDECK/WMS SWITCHLIST WILL BE DELAYED FOR AN EXTENDED PERIOD TO ACCOMODATE LATE MIDDECK STOWAGE. 14-1225 OTC CTPE ACTIVATE "ANY CHANGE SWITCH SCAN" 132 MONITOR PROGRAM (STP05). REPORT COMPLETE. NOT PERFORMED ______ 418 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IUS POST POWER UP CHECKOUT COMPLETE | ----------------------------------- | | NOTE | | PERFORM THE NEXT STEP | FOR IUS MISSION (STS-93). | | PERFORM NEXT STEP AT L-18:45. | | 14-1226 ICTC PTC IUS CHECKOUT COMPLETE PER S0007VL4 | 134 (SEQ 78). | PTC NTD | 232 | | IUS QUIET TIME REQUEST | ---------------------- | | NOTE | | PERFORM THE NEXT STEP | FOR IUS MISSION (STS-93). | | PERFORM NEXT STEP AT L-16:35. | | 14-1227 ICTC PTC READY TO PROCEED WITH RIMU CAL AND | 134 ALIGN. REQUEST QUIET TIME BE PLACED | PTC NTD IN EFFECT IN 15 MINUTES. | 232 | NTD OTC | TBC | STM | NOT PERFORMED ______| 419 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE | | PERFORM IUS QUIET TIME | START NEXT FOUR STEPS FOR | IUS MISSION (STS-93). | | IUS QUIET TIME START | -------------------- | | NOTE | | FOLLOWING CRITERIA REQUIRED | FOR QUIET TIME ACTIVITY: | | 1. NO HYDRAULICALLY ACTUATED | AEROSURFACE OR SSME TVC | MOVEMENT | | 2. NO SRB NOZZLE MOVEMENT | | 3. NO MPS 17-INCH DISCONNECT | VALVE CYCLES | | 4. NO UNCOORDINATED CABIN | ACTIVITY | | 5. NO CHANGES IN PLB PURGE | (FLOW RATE OR TEMP) | | 6. NO 3,4,5,6,7 OR 9 VENT | DOOR OPERATIONS | | 7. NO SSME FRT OR OTHER | OPERATIONS RESULTING IN | SIMULATED SSME PNEUMATIC | SHUTDOWN. | | 8. MAX WIND OF 49 KNOTS | (PEAK VELOCITY IN ANY | DIRECTION). | | 9. NO MOBILE CRANE OPERATIONS | | 10. NO ORBITER WEATHER | PROTECTION MOVEMENT | | 11. NO ORBITER CRYOGENIC | CHILLDOWN | 420 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- | NOTE | | PERFORM THE NEXT STEP AT | L-16H20M. | | 14-1228 -11H00M NTD PTC PROCEED WITH RIMU CAL AND ALIGN. | (HOLDING) 232 QUIET TIME IN EFFECT. | | OMRSD P018JB.035-C | | NOT PERFORMED ______| | NOTE | | DURING RIMU CAL/ALIGN, PTC | WILL REQUEST PAYLOAD BAY | PURGE, WIND DIRECTION AND | VELOCITY DATA EVERY 30 MIN. | PTC WILL RECORD THIS DATA | IN APPENDIX B (S0007VL4). | | 14-1229 PTC OTC PROVIDE TEMPERATURE, FLOWRATE AND | 132 HUMIDITY OF PAYLOAD BAY PURGE PER | OTC CPVD ORBITER OPERATION SUPPORT SETUP 15. | PTC WILL REQUEST DATA EVERY 30 MIN | DURING RIMU CAL/ALIGN. NOTIFY PTC | IMMEDIATELY OF ANY VIOLATIONS. | | NOT PERFORMED ______| | 14-1230 PTC NTD REQUEST WIND DIRECTION AND VELOCITY | 232 READING FROM 60 FT WIND TOWERS. | NTD STM | STM JBDY RECORD: | 111 | JBDY *WEA WIND DIRECTION__________ | 231 | WIND VELOCITY__________ | | NOT PERFORMED ______| 421 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IUS RIMU CAL AND ALIGN START | ---------------------------- | | NOTE | | PERFORM NEXT STEP AT L-16H15M. | | 14-1231 -11H00M PTC ICTC PROCEED WITH RIMU CAL AND ALIGN | (HOLDING) 134 PER DOP D290-50020-27. QUIET TIME | IN EFFECT. REPORT STATUS OF CAL | AND ALIGN AS AVAILABLE. | | NOT PERFORMED ______| | | FUEL CELL FLOW THRU/PULSE PURGE ------------------------------- NOTE MINIMIZE TIME BETWEEN INITIATION OF FUEL CELL REACTANT PURGE AND FUEL CELL START. DO NOT PERFORM NEXT TWO STEPS IF FUEL CELLS ARE POWERED UP (SCRUB/RECYCLE). 14-1232 -11H00M NTD OTC PERFORM FUEL CELL FLOW THRU/ SU72446 (HOLDING) 232 STM PULSE PURGE PER OMI V1040.002 OTC CFCP ON OIS CH 153. (1 HR 15 MIN). 132 NOT PERFORMED ______ 14-1233 STM JBPN MONITOR GO2 AND GH2 SYSTEMS FOR PNSA 111 EXCESSIVE SYSTEM DECAY DURING FUEL CELL FLOWTHRU/PULSE PURGE THRU T-0. NOT PERFORMED ______ 422 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VACUUM VENT LINE INERTING ------------------------- 14-1234 OTC CECL INITIATE VACUUM VENT LINE DUCT SU72449 132 GN2 INERTING PER ORBITER OPERATION SUPPORT SETUP 5 (S0007VL1). (1 HR) ASCENT SWITCHLIST COMPLETE -------------------------- 14-1235 -11H00M OTC NTD ORBITER ASCENT SWITCHLIST SU72463 (HOLDING) 232 COMPLETE. (SEQ 76 S0007VL4). 423 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM THE FOLLOWING STEP IMMEDIATELY AFTER COMPLETION OF C/W SETUPS IN THE ASCENT SWITCHLIST. 14-1236 OTC CISL PERFORM C/W GOAL SOFTWARE UPDATE | 132 FOR ASCENT SWITCHLIST PER | OMI S9001VL2. (15 MINUTES) | NOTE PERFORM NEXT TWO STEPS IF DTO 685 (ELECTRONIC KNEEBOARD) IS INSTALLED. 14-1237 OTC ASP MIDDECK LOCKER _____ DTO 685 (ELECTRONIC KNEEBOARD) POWER ON EXPERIMENT PER YOUR CHECKLIST NOT PERFORMED ______ 14-1238 ASP PANEL L12L SSP2 PDIP POWER 1 CB - CLOSED PDIP DC POWER 1 CABIN P/L - ON NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF FCE LATE STOW NOT COMPLETED PRIOR TO ASCENT SWITCHLIST. 14-1239 NTD OTC ASCENT SWITCHLIST COMPLETE. 232 CONTINUE WITH FCE LATE STOW. OTC OOCS 132 NOT PERFORMED ______ 14-1240 OTC CTPE PERFORM ASCENT SWITCH SCAN PER SU72555 132 STP08. 424 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SWITCHLIST POST OPERATIONS -------------------------- NOTE SUPPORT CREW REP WILL INSTALL FOLLOWING AT COMPLETION OF SWITCHLIST: 1. ASCENT CUE CARDS 2. COMBINED WICKET ON PNL O8 AT LH SIDE OF SWITCHES MARKED "FWD RCS HE PRESS A, TANK ISOLATION 1/2, MANIFOLD ISOLATION 1" BY MATING VELCRO AND SNAPS. 14-1241 OTC ASP UNLOCK AND REMOVE LOCKS FROM RCS SU72554 132 DRIVER SWITCHGUARDS ON PANELS O14, O15, AND O16. DO NOT REMOVE SWITCHGUARDS. RETAIN IN WITH SWITCHGUARD SET FOR REINSTALLATION IF LAUNCH SCRUB OCCURS. 14-1242 CTPE OTC ASCENT SWITCH SCAN COMPLETE. 132 NOTE PERFORM NEXT STEP IF "ANY CHANGE SWITCH SCAN" NOT PREVIOUSLY ACTIVATED. 14-1243 OTC CTPE ACTIVATE "ANY CHANGE SWITCH SCAN" 132 MONITOR PROGRAM (STP05). REPORT COMPLETE. NOT PERFORMED ______ NOTE NEXT STEP WILL BE VERIFIED SHORTLY AFTER COMPLETION OF ASCENT SWITCHLIST. 14-1244 *PAD OTC ORBITER OPERATION SUPPORT SETUP SU72460 132 16 - SWITCHGUARD IDENTIFICATION COMPLETE. 425 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FUEL CELL FLOW-THRU PURGE ------------------------- - COMPLETE CONTINUE W/PULSE PURGE --------------------------------- NOTE DO NOT PERFORM NEXT FOUR STEPS IF FUEL CELLS ARE POWERED UP (SCRUB/RECYCLE) OR UNTIL ASCENT SWITCHLIST (FD, AFD, MD PORTIONS) IS REPORTED COMPLETE. 14-1245 CFCP OTC FUEL CELL FLOW THRU PURGE SU72540 132 COMPLETE. CONTINUING WITH FUEL SU72446 OTC CECL CELL PULSE PURGE. (45 MIN) 232 NTD O2 ECS VALVES WILL BE OPENED TO SUPPORT O2 SEAT SAMPLES. NOT PERFORMED ______ 14-1246 CFCP ASP PANEL L2 132 ATM PRESS CONTROL O2 SYS 1 SUPPLY SW - OPEN L2A01S01 UNTIL O2 SYS 1 SUPPLY TB OP L2A01DS05 O2 SYS 2 SUPPLY SW - OPEN L2A01S02 UNTIL O2 SYS 2 SUPPLY TB OP L2A01DS09 NOT PERFORMED ______ 14-1247 CFCP OTC MASTER ALARMS WILL OCCUR FOR FUEL 132 CELL REACTANT VLV CLOSURE. REQUEST OTC ASP ASP RESET. CISL NOT PERFORMED ______ 426 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SEAT O2 SAMPLES (ECLSS) ----------------------- 14-1248 OTC CECL PERFORM ECLSS O2 SAMPLE FOR SU72564 132 ASP SUITED CREW INGRESS PER S0007VL4 (SEQ 45 OPTION C) ON OIS CH 143 (30 MIN). NOT PERFORMED ______ OI SNAPSHOT ----------- NOTE OI SNAPSHOT SHOULD BE PERFORMED AFTER COMPLETION OF ASCENT SWITCHLIST. CTPE SHALL CALL DATA COORDINATOR FOR PICKUP AND DELIVERY (OI SNAPSHOTS) TO CISL FOR NEXT STEP. 14-1249 -11H00M NTD JRPS PERFORM OI SNAPSHOTS SU72545 (HOLDING) 232 (2 COPIES). 14-1250 JRPS NTD OI SNAPSHOT COMPLETE. 232 NTD OTC OTC CTPE 132 APU BITE TEST ------------- 14-1251 -11H00M OTC CAPU PERFORM APU BITE TEST PER SU72547 (HOLDING) 132 S0007VL4 (SEQ 42). (15 MIN) 14-1252 CAPU OTC APU BITE TEST COMPLETE 132 (SEQ 42, S0007VL4). 427 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- C/W AND LCC EMON ACTIVATION --------------------------- 14-1253 -11H00M OTC CECL ACTIVATE C/W & LCC EMON FOR SU72552 (HOLDING) 132 CMPS YOUR SYSTEM PER SEQ 39 C&W & COOS LCC EMON ACTIVATION. (S0007VL4) CTPE TPE SUPPORT RSYS XFER WITH COOS ON CH 157. REPORT COMPLETION AND NOT PERFORMED STEPS (15 MIN) CECL __________ CMPS __________ COOS __________ GOX VENT HOOD/ET ALIGNMENT -------------------------- 14-1254 -11H00M TBC CMEC PERFORM GOX VENT HOOD/ET SU72466 (HOLDING) 136 ALIGNMENT PER OMI G2158. EQUIPMENT CONFIGURED (JFIR) - COMPLETE -------------------------------------- 14-1255 -11H00M JFIR JSTC FINAL RSS, FSS, MLP AND PAD FIRE (HOLDING) 114 APRON WALKDOWN COMPLETE. FIRE SU72360 JSTC STM EXTINGUISHERS REMOVED. TWO FIRE 111 EXTINGUISHERS PLACED IN EACH STM NTD ELEVATOR. 232 NTD OTC *SCC 14-1256 -11H00M JFIR JSTC MLP ZERO LEVEL FIRE ALARM PULL FIRE (HOLDING) 114 STATIONS AND ALARM GONG BELL SU72361 REMOVED. 428 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 02H30M TO END OF HOLD --------------------- 14-1257 -11H00M STM JBPN REMOVE BARRICADES FROM AROUND PNSA (HOLDING) 111 GO2 SUPPLY PANEL AND STORAGE BOTTLES (1 HR). T:______ 14-1258 JBPN STM BARRICADES REMOVED FROM AROUND PNSA 111 GO2 STORAGE BOTTLES AND PANEL. 02H20M TO END OF HOLD --------------------- CCF-39 GN2 PRODUCTION PLANT --------------------------- LPGN2 NOTIFICATION ------------------ NOTE LN2 PUMPS REQUIRED IN 4 HOURS FOR HIGH FLOW RATE AND AIR TO GN2 CHANGEOVER (V1122). 14-1259 -11H00M STM JSTC CCF-39 GN2 PRODUCTION PLANT 4 PNU (HOLDING) 111 HOUR NOTIFICATION. SU72493 JSTC GSPN 114 14-1260 -11H00M STM JSTC PLACE AND CONNECT GN2 PNU (HOLDING) 111 RECHARGER(S) AND LN2 TANKERS PN JSTC GSPN TO CCF-39 RECHARGER MANIFOLD 114 BY T-6 HRS. NET GSPS 104 TERMINATE VOICE CHECKS ---------------------- 14-1261 -11H00M STM GYCC DO NOT PERFORM VOICE CHECKS FOR COMM (HOLDING) 111 REMAINDER OF LAUNCH COUNTDOWN. GYCC GYCR PTP 429 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- REMOVE AREA WARNING KEYS ------------------------ AND MICROPHONES --------------- NOTE REMOVE THOSE KEYS AND MICROPHONES FROM CONSOLES NOT MANNED BY A NTD OR CTC. 14-1262 -11H00M NTD STM REMOVE AREA WARNING KEYS AND COMM (HOLDING) 232 MICROPHONES FROM CONSOLES STM GYCC DESIGNATED BY NTD/STM. ATTACH 111 INTEGRITY CONTROL STICKERS TO GYCC JYCJ KEY HOLES AND TURN KEYS IN TO 117 JSOQ STM. (30 MIN) LCC-1 CONSOLE AB-6 NOT PERFORMED ______ LCC-2 CONSOLE AA-5 NOT PERFORMED ______ LCC-3 CONSOLE AB-6 NOT PERFORMED ______ TQV:____ 430 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1263 -11H00M JYCJ GYCC IF DESIGNATED BY NTD/STM, AREA COMM (HOLDING) 117 WARNING KEYS AND MICROPHONES GYCC STM HAVE BEEN REMOVED FROM FOLLOWING 111 CONSOLES AND KEYS TURNED IN TO STM. STM NTD INTEGRITY CONTROL STICKERS HAVE 232 BEEN ATTACHED TO KEY HOLES LCC-1 CONSOLE AB-6 NOT PERFORMED ______ LCC-2 CONSOLE AA-5 NOT PERFORMED ______ LCC-3 CONSOLE AB-6 NOT PERFORMED ______ 14-1264 STM JBPN ON RSS 130 FT LEVEL, CLOSE O2N2 PNSA 111 BREATHING AIR SUPPLY VALVE SU72508 A138340. T:______ 431 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- BREATHING AIR PANEL REMOVAL --------------------------- 14-1265 -11H00M STM JSTC PERFORM FOLLOWING: (2 HRS) LS (HOLDING) 111 SU72511 JSTC *SCB 1. FASTEN SNAP HALYARDS TO ELSA NET BOX LATCHES ON RSS AND MLP. 104 2. REMOVE ELSA BOX FROM 135 FT EAST SIDE AND ANY OTHER ELSA BOXES WITHOUT HOLDDOWN CABLES AND ANY LOOSE LIFE SUPPORT EQUIPMENT FROM RSS AND MLP. 3. REMOVE ORBITER AFT RESCUE EQUIPMENT FROM RSS SIDE 2 130 FT LEVEL (50-2 ACCESS DOOR) AND REMAINING BREATHING AIRLINES FROM 130 FT LVL (50-1/2), "0" LVL MLP, 107 FT, 120 FT, AND 207 FT LEVELS OF RSS. 4. DISCONNECT BREATHING AIR PANEL FROM RSS. AFTER LOWERED TO PAD SURFACE TAKE TO SLIDEWIRE BUNKER AND CONNECT PANEL TO K-BOTTLE MANIFOLD, SET TO 80 PSIG +20/-0 PSIG AND PERFORM A 5 MINUTE PURGE. VERIFY BREATHING AIR MANIFOLD PRESSURIZED TO 1800 LBS MINIMUM. NOTE IF MLP OTV CAMERAS ARE ADJUSTED AFTER FINAL CHECKS, JYVO SHALL NOTIFY STM/JBPN ON OIS CH 111 AND STATUS CAMERA NUMBER(S) AND LOCATION(S). 14-1266 STM JBPN VERIFY MLP CAMERA FLEXHOSES PNSA 111 SECURELY ATTACHED PER OMI M3197. SU72487 432 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CANTILEVER/JIB HOISTS REMOVAL COMPLETE -------------------------------------- NOTE PERFORM NEXT STEP IF CANTILEVER/JIB HOISTS ARE REMOVED PER B5150. 14-1267 PBOL *PAD CANTILEVER/JIB HOISTS REMOVAL COMPLETE. *PAD TBC 136 NOT PERFORMED ______ NOTE PERFORM MPS LH2 FEED AND RECIRC DISCONNECT CONFIGURE FOR LOAD TWO HOURS PRIOR TO END OF HOLD IF ORBITER MPS FEED AND RECIRC DISC VALVES ARE CLOSED. MPS LH2 FEED AND RECIRC DISCONNECT ---------------------------------- CONFIGURE FOR LOAD ------------------ NOT PERFORMED ______ 14-1268 TBC CLHY PERFORM OMI G3251 OSSU 3 - SU72457 136 DEPRESSURIZATION AND RE-PRESSURIZATION OF ET LH2 TANK AND MPS FEED AND RECIRC DISCONNECT VALVES OPENING. 14-1269 CLHY TBC VERIFY WIND SPEED FORECAST AT 136 60 FT LEVEL OF LAUNCH PAD WEATHER TBC NTD TOWER WILL NOT EXCEED 47 KNOTS 232 FOR NEXT HOUR. NTD STM STM JBDY 111 JBDY *WEA 231 OMRSD S00L00.051-A-1 433 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1270 -11H00M CLHY TBC REQUEST CMPS SWITCH TO OIS CH 166 TO (HOLDING) 136 SUPPORT G3251 LH2 SYSTEM PREPS FOR TBC OTC VEHICLE LOADING. REPORT TO CLHY. 132 NOTE DO NOT PERFORM NEXT FOUR STEPS IF RSS IS ROLLED BACK (PARK POSITION) AND LH2 TSM CLOSED OUT FOR FLIGHT. 14-1271 CMPS OTC LOUD HELIUM VENTING WILL OCCUR SU72522 132 FROM MPS LH2 RTLS DUMP PORT. OTC NTD REQUEST SAFETY NOTIFY PERSONNEL 232 WORKING IN LH2 TSM/T-0 CARRIER NTD *SCC PLATE LOUD VENTING WILL OCCUR *SCC *PSE MOMENTARILY. REQUEST SAFETY NET VERIFY NO PERSONNEL IN LINE OF 105 LH2 RTLS DUMP PORT EXIT, LOCATED NEAR 50-1 DOOR, AND NOTIFY ALL PERSONNEL IN VICINITY OF DUMP PORT THAT LOUD VENTING WILL OCCUR, REQUEST SAFETY REMAIN ON STATION UNTIL VENTING IS COMPLETE. NOT PERFORMED ______ 14-1272 *PSE *SCC PERSONNEL HAVE BEEN NOTIFIED AND NET NO LONGER IN VICINITY OF LH2 RTLS 105 DUMP PORT. YOU HAVE SAFETY *SCC NTD CONCURRENCE TO PROCEED. 232 NTD OTC OTC CMPS 132 NOT PERFORMED ______ 14-1273 CMPS OTC ATTENTION ON PAD ___: 132 OTC NTD HELIUM WILL BE VENTED THROUGH RTLS 232 DUMP PORT IN AREA OF 50-1 DOOR. NTD PA NOT PERFORMED ______ 434 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1274 CMPS OTC HELIUM VENTING FROM LH2 RTLS 132 DUMP PORT NEAR OBITER 50-1 DOOR OTC NTD COMPLETE. SAFETY MAY BE RELEASED 232 AT THIS TIME. NTD *SCC *SCC *PSE NET 105 NOT PERFORMED ______ 14-1275 CLHY TBC ATTENTION ON PAD ___: 136 TBC NTD ET LH2 TANK WILL BE VENTED TO 232 LH2 FLARE STACKS. NTD PA OPEN LH2 17 IN. DISCONNECT -------------------------- 14-1276 CMPS OTC REQUEST NO TCS PGM ACTIVE (OTHER 132 THAN MPS) DURING LH2 17 IN. DISC OTC NTD VALVE CYCLE TO OPEN AND LATCH 232 TO LOCK. NTD TBC 14-1277 NTD OTC PROCEED WITH LH2 17 IN. DISC VALVE 232 AND LATCH CYCLING PER OMI G3251. OTC CMPS 132 14-1278 CMPS OTC LH2 17 IN. DISCONNECT IS OPEN AND 132 LATCH IS IN LOCKED POSITION PER OTC NTD G3251. TCS PGM ACTIVITY MAY 232 RESUME. NTD TBC OMRSD S00FA0.810-B 14-1279 CLHY TBC G3251 OPERATION SUPPORT SETUP SU72457 136 3 - DEPRESSURIZATION AND TBC NTD REPRESSURIZATION OF ET LH2 TANK 232 AND MPS FEED AND RECIRC DISCONNECT VALVE OPENING COMPLETE. MPS LH2 FEED AND RECIRC DISCONNECT ---------------------------------- CONFIGURE FOR LOAD COMPLETE --------------------------- 435 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT 11 STEPS APPROXIMATELY 2 HRS PRIOR TO COMING OUT OF T-11 HR HOLD. SEAL SRB TUNNEL DRAIN HOLES --------------------------- NOTE DO NOT PERFORM NEXT FOUR STEPS IF SRB DRAIN HOLES ALREADY SEALED. DO NOT WORK NEXT FOUR STEPS CONCURRENTLY WITH SRB HPU EXHAUST PLUG AND OVERBOARD DRAIN LINE REMOVAL. 14-1280 NTD TBC VERIFY AFT SKIRT PURGE NOT 232 FLOWING. NOT PERFORMED ______ 14-1281 TBC NTD REQUEST CONCURRENCE FOR PERSONNEL 232 TO ENTER CONTROL AREA AROUND SRB NTD *SCC AFT SKIRTS TO SEAL SRB DRAIN HOLES. *SCC *PSE AFT SKIRT PURGE NOT ACTIVE. NET 105 NOT PERFORMED ______ 436 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1282 *PSE *SCC PERSONNEL ENTERING CONTROL AREA NET AROUND SRB AFT SKIRTS PROPERLY 105 ATTIRED AND WEARING BODY HARNESSES. *SCC NTD YOU HAVE SAFETY CONCURRENCE TO 232 ENTER CONTROL AREA AND SEAL SRB NTD TBC DRAIN HOLES. NOT PERFORMED ______ 14-1283 -11H00M TBC *PAD PERFORM SRB OPERATION SUPPORT SU72474 (HOLDING) 136 PBOL SETUP 1 - SEAL SRB DRAIN HOLES. (S0007VL1) NOT PERFORMED ______ RLDS 6145 ACTIVATION AND CONFIDENCE ----------------------------------- CHECKS ------ 14-1284 CHGD TBC PERFORMING RLDS 6145 ACTIVATION SU72470 136 CLHY AND CONFIDENCE CHECKS. IGNORE RLDS 6145 LEAK DETECTOR INDICATIONS UNTIL COMPLETION. __________ GMT 14-1285 CHGD PETG FSS 195 FT LEVEL - 6145 CABINET 177 1. GN2 PURGE VALVE A152873 - OPEN (CCW) 2. VERIFY AUDIBLE PURGE T:______ 437 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE EMONS MAY OCCUR AT CLHY CONSOLE DURING LEAK DETECTOR ACTIVATION. 14-1286 CHGD CURSOR CNTL (SAW01/HWW11) MFC POWER - ON PUMP 1 - ON PUMP 3 - ON XMIT CURSOR KEY - PRESS NOTE ALLOW A 5 MINUTE MINIMUM MFC WARMUP PRIOR TO DATA RECORDING. MANUAL SELECT SV3 (CAL) SV4 (CAL) HE Z CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT VERIFY AND RECORD PRIMARY INDICATIONS LD24 = __________PPM 0 +/-4000 LD50 = __________PPM 0 +/-4000 LD23 = __________PPM 0 +/-6000 LD25 = __________PPM 0 +/-6000 MFC1 = __________SLPM 4.0 +/-0.5 MFC3 = __________SLPM 4.0 +/-0.5 MFC5 = __________SLPM 2.8 +/-0.5 MFC7 = __________SLPM 2.8 +/-0.5 438 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE LEAK DETECTORS SHOULD BE CONDITIONED WITH SPAN GAS AT LEAST THREE TIMES PRIOR TO DATA RECORDING. 14-1287 CHGD CURSOR CNTL (SAW01/HWW11) HE T CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT VERIFY AND RECORD PRIMARY INDICATIONS LD23 = __________PPM BD LD25 = __________PPM BD MFC5 = __________SLPM (2.8 +/-.5) MFC7 = __________SLPM (2.8 +/-.5) SUPPORT MODE XMIT CURSOR KEY - PRESS 14-1288 CHGD TBC RLDS 6145 ACTIVATION AND CONFIDENCE 136 CLHY CHECKS COMPLETE. NO ANOMALIES NOTED. __________GMT RLDS 6407 ACTIVATION AND CONFIDENCE ----------------------------------- CHECKS ------ 14-1289 CHGD TBC PERFORMING RLDS 6407 ACTIVATION AND 136 CHLY CONFIDENCE CHECKS. IGNORE RLDS 6407 LEAK DETECTOR INDICATIONS UNTIL COMPLETION. __________GMT 439 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1290 CHGD CURSOR CNTL (SAW01/HWW12) MFC POWER - ON PUMP 1 - ON PUMP 3 - ON XMIT CURSOR KEY - PRESS NOTE ALLOW A 5 MINUTE MINIMUM MFC WARMUP PRIOR TO DATA RECORDING. MANUAL SELECT SV1 (CAL) SV2 (CAL) SV3 (CAL) SV4 (CAL) HE Z CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT VERIFY AND RECORD PRIMARY INDICATIONS LD28 = __________PPM 0 +/-6000 LD32 = __________PPM 0 +/-6000 LD56 = __________PPM 0 +/-6000 LD57 = __________PPM 0 +/-6000 MFC1 = __________SLPM 2.8 +/-0.5 MFC3 = __________SLPM 2.8 +/-0.5 MFC5 = __________SLPM 2.8 +/-0.5 MFC7 = __________SLPM 2.8 +/-0.5 440 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE LEAK DETECTORS SHOULD BE CONDITIONED WITH SPAN GAS AT LEAST THREE TIMES PRIOR TO DATA RECORDING. 14-1291 CHGD CURSOR CNTL (SAW01/HWW12) HE T CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT VERIFY AND RECORD PRIMARY INDICATIONS LD28 = __________PPM BD LD32 = __________PPM BD LD56 = __________PPM BD LD57 = __________PPM BD MFC1 = __________SLPM 2.8 +/-0.5 MFC3 = __________SLPM 2.8 +/-0.5 MFC5 = __________SLPM 2.8 +/-0.5 MFC7 = __________SLPM 2.8 +/-0.5 SUPPORT MODE XMIT CURSOR KEY - PRESS 14-1292 CHGD TBC RLDS 6407 ACTIVATION AND CONFIDENCE 136 CLHY CHECKS COMPLETE. NO ANOMALIES NOTED. __________GMT RLDS 6660 CONFIDENCE CHECKS --------------------------- 14-1293 CHGD TBC PERFORMING RLDS 6660 ACTIVATION AND 136 CLHY CONFIDENCE CHECKS. IGNORE RLDS 6660 LEAK DETECTOR INDICATIONS UNTIL COMPLETION. __________GMT 441 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1294 CHGD CURSOR CNTL (SAW01/HWW13) PUMP 3 - ON XMIT CURSOR KEY - PRESS MANUAL SELECT SV1 (CAL) SV2 (CAL) N2 Z CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT VERIFY AND RECORD PRIMARY INDICATIONS LD29 = __________PPM 0 +/-4000 LD30 = __________PPM 0 +/-4000 LD54 = __________PPM 0 +/-4000 LD55 = __________PPM 0 +/-4000 MFC1 = __________SLPM 4.0 +/-0.5 MFC3 = __________SLPM 4.0 +/-0.5 MFC5 = __________SLPM 4.0 +/-0.5 MFC7 = __________SLPM 4.0 +/-0.5 NOTE LEAK DETECTORS SHOULD BE CONDITIONED WITH SPAN GAS AT LEAST THREE TIMES PRIOR TO DATA RECORDING. 14-1295 CHGD CURSOR CNTL (SAW01/HWW13) N2 S CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT VERIFY AND RECORD PRIMARY INDICATIONS LD29 = __________PPM BD LD30 = __________PPM BD MFC1 = __________SLPM (4.0 +/-0.5) MFC3 = __________SLPM (4.0 +/-0.5) SUPPORT MODE XMIT CURSOR KEY - PRESS 442 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE LEAK DETECTORS SHOULD BE CONDITIONED WITH AIRS GAS | AT LEAST THREE TIMES PRIOR TO DATA RECORDING. 14-1296 CHGD CURSOR CNTL (SAW01/HWW13) MANUAL SELECT SV3 (CAL) SV4 (CAL) AIR S CURSOR BLOCK XMIT CURSOR KEY - PRESS CRT VERIFY AND RECORD PRIMARY INDICATIONS LD54 = __________PPM BD LD55 = __________PPM BD MFC5 = __________SLPM (4.0 +/-0.5) MFC7 = __________SLPM (4.0 +/-0.5) SUPPORT MODE XMIT CURSOR KEY - PRESS 14-1297 CHGD TBC RLDS 6660 ACTIVATION AND SU72470 136 CLHY CONFIDENCE CHECKS COMPLETE. NO ANOMALIES NOTED. __________GMT HAZ WARNING MONITOR TRANSFER ---------------------------- 14-1298 CHGD CLHY LH2 LEAK AND FIRE DETECTORS READY TO 166 SUPPORT ET LH2 LOADING OPERATIONS. 14-1299 CLHY CLH2 CURSOR CNTL (GAH51 LEAK AND FIRE DISPLAY) GAW02 INIT - ON (INITIATES GAW02) 14-1300 CLHY TBC HAZ WARNING MONITOR TRANSFER COMPLETE. 136 CHGD 443 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SECURE OIC MONITOR SHACK ------------------------ 14-1301 OTC *PAD AT OIC MONITOR SHACK ON PAD SU72366 132 SURFACE DISCONNECT PLUG FROM FACILITY POWER AND STOW CABLE INSIDE OIC SHACK. REPORT COMPLETION. 14-1302 -11H00M STM GYCC PERFORM FOLLOWING: (HOLDING) 111 GYCC JYCJ 1. LOCKOUT PAD SURFACE OIC COMM 117 MONITOR SHACK ADMIN TELEPHONE IN PTCR RM 203. (PAD A - 861-1151, SW 5; PAD B - 861-1152, SW 7) 2. DISCONNECT TELEPHONE INTERFACE AT PAD SURFACE OIC MONITOR SHACK AND LEAVE CORD COILED IN SHACK. 3. REPORT COMPLETION. 14-1303 STM GBHE CLEAR NONESSENTIAL PERSONNEL | NET FROM 25 FT AROUND OIC MONITOR | 104 SHACK ON 135 FT LEVEL RSS AND | 50 FT AT PAD SURFACE FOR LIFTING | OPERATIONS. | | WARNING | | MONITOR SHACK REMOVAL IS | HAZARDOUS DUE TO LIFTING | OPERATION. | | 14-1304 GBHE STM CLEAR ESTABLISHED FOR OIC MONITOR | NET SHACK LIFT FROM RSS 135 FT LEVEL. | 104 COMMENCING NOMITOR SHACK REMOVAL. | STM NTD | 232 | NTD OTC | *SCC | OTC *PAD | 132 | *SCC *PSE | NET | 105 | | 444 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1305 GBHE STM MONITOR SHACK REMOVAL FROM 135 FT | NET LEVEL COMPLETE. CLEARS ARE DOWN. | 104 | STM NTD | 232 | NTD OTC | *SCC | OTC *PAD | 132 | *SCC *PSE | NET | 105 | | 14-1306 STM QBSE UNBOLT OIC MONITOR SHACK AND STSA | NET TETHER STATION ON PAD SURFACE. 104 T:______ 14-1307 STM JBDY REMOVE OIC MONITOR SHACK AND HESA 111 TETHER STATION FROM PAD SURFACE. | JBDY GBHE (45 MIN) NET 104 445 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET GOX VENT HOOD PURGE PREPS ---------------------------- NOTE NEXT STEP WILL BE PERFORMED 1HR 40 MIN PRIOR TO COMING OUT OF HOLD. 14-1308 -11H00M CMEC TBC PERFORM M3703 PREPS TO SUPPORT JSTC (HOLDING) 136 G2158, ET GOX VENT HOOD GN2 PNU TBC NTD PURGE. SU72503 232 NTD STM STM JSTC 111 JSTC GSPN 114 14-1309 -11H00M GSPN JSTC M3703 PREPS TO SUPPORT G2158, PNU (HOLDING) JSTC STM ET GOX VENT HOOD GN2 PURGE SU72503 111 COMPLETE. STM NTD 232 NTD TBC TBC CMEC 136 NOTE DO NOT PERFORM NEXT STEP FOR SCRUB TURNAROUND IF SYSTEM HAS REMAINED CONFIGURED. 14-1310 JBFX STM PAD WASHDOWN SYSTEM CONFIGURATION WSSA 111 COMPLETE FOR SEQUENCER PANEL SU72496 ARMING PER M3190. NOT PERFORMED ______ 446 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PTCR WATER/WASHDOWN SYSTEMS --------------------------- CLOSEOUT -------- NOTE DO NOT PERFORM NEXT TWO STEPS IF SYSTEM HAS REMAINED CONFIGURED FROM PREVIOUS RUN OF S0007. 14-1311 -11H00M STM JBFX PERFORM PTCR ROOM 210 WATER WSSA | (HOLDING) 111 CLOSEOUT PER OMI M3190. (1 HR) NOT PERFORMED ______ 14-1312 STM JBFX CONFIGURE PTCR AND PAD WASHDOWN WSSA 111 SYSTEMS FOR REMOTE OPERATION SU72497 PER OMI M3190 (1 HR). SU72481 NOT PERFORMED ______ 14-1313 JBWC STM MLP SS LINE FILL TO 105 FT LEVEL WSSA 111 AND 48 INCH BYPASS VALVES CLOSED. STM NTD ORBITER/SRB ESP AREAS AND FLAME 232 TRENCH MAY BE OPENED FOR CONTROLLED WORK. 14-1314 NTD *SCC SS TANK FILL TO 105 FT LEVEL 232 COMPLETE. REQUEST SAFETY OPEN *SCC *PSE ORBITER/SRB ESP AREAS AND FLAME NET TRENCH FOR CONTROLLED WORK. 105 447 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1315 *PSE *SCC ORBITER/SRB ESP AREAS AND FLAME NET TRENCH OPEN FOR CONTROLLED WORK. 105 *SCC NTD 232 NTD OTC STM 00H50M TO END OF HOLD --------------------- SOUND SUPPRESSION WATERTANK FILL -------------------------------- COMPLETE -------- NOTE DO NOT PERFORM NEXT STEP IF SS WATER TANK HAS REMAINED FILLED FROM PREVIOUS RUN OF S0007. 14-1316 -11H00M JBWC STM SOUND SUPPRESSION TANK FILL WSSA (HOLDING) 111 COMPLETE. SU72369 STM NTD 232 NOT PERFORMED ______ SOUND SUPPRESSION TANK TOP OFF COMPLETE --------------------------------------- NOTE PERFORM NEXT STEP IF SS WATER TANK TOP OFF WAS REQUIRED FOR SCRUB TURNAROUND. 14-1317 JBWC STM SS ELEVATED TANK TOP OFF WSSA 111 COMPLETE. NOT PERFORMED ______ 448 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE SOUND SUPPRESSION TRICKLE ---------------------------------- FLOW SYSTEM ----------- NOTE PERFORM NEXT STEP IF THE SOUND SUPPRESSION TRICKLE FLOW WAS DEACTIVATED FOR ORBITER ESP LOWERING OR IF THIS SEQUENCE IS PERFORMED FOLLOWING A SCRUB TURNAROUND AND THE SS TRICKLE FLOW SYSTEM WAS SECURED. 14-1318 STM JBWC ACTIVATE SOUND SUPPRESSION WSSA 111 TRICKLE FLOW SYSTEM PER SU72414 OMI M3189.001. (1 HR) NOT PERFORMED ______ HYDRAULIC WALKDOWN COMPLETE --------------------------- 14-1319 -11H00M *PAD OTC ORBITER OPERATION SUPPORT SETUP SU72407 (HOLDING) 132 27 - HYDRAULIC PRE-LAUNCH WALKDOWN COMPLETE. 14-1320 STM NTD PNEUMATICS WILL BE ADJUSTING FACILITY 232 GHE AND GN2 PANELS. PRESSURE NTD OTC FLUCTUATIONS WILL OCCUR. THESE TBC ACTIVITIES WILL LAST APPROX 2 HRS. 449 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 00H40M TO END OF HOLD --------------------- HIGH PRESSURE GAS PANEL OPERATIONAL ----------------------------------- CHECK ----- 14-1321 -11H00M NTD STM PERFORM OPERATIONAL CHECK ON PNSA (HOLDING) 232 THE FOLLOWING SUPPORT PANELS. STM JBPN (2 HRS) 111 1. 6000/3000 PSIG REG PANEL - H.P. GAS STORAGE BATTERY PER OMI M3011 2. GN2 PRIMARY REGULATION PANEL- FSS 175 FT LEVEL PER OMI M3011 3. GHE PRIMARY REGULATION PANEL- FSS 175 FT LEVEL PER OMI M3131 4. PAD GN2 PURGE PANEL - FSS 175 FT LEVEL PER OMI M3054/ OMI M3176 5. MLP GN2 REGULATION PANEL- COMPT 1B PER OMI M3197 6. MLP GN2 PURGE PANEL - COMPT 44A PER OMI M3197. 7. MLP LPGN2 SUPPLY PER OMI M3197. 8. SLIDEWIRE BUNKER EMERGENCY BREATHING AIR SYSTEM PANEL U72-1307. VERIFY PANEL SUPPLY GAGE READS MINIMUM 1800 PSIG. RECORD PRESSURE __________ PSIG PTCR WATER CLOSEOUT COMPLETE ---------------------------- NOTE DO NOT PERFORM NEXT STEP IF SYSTEM HAS REMAINED CONFIGURED FROM PREVIOUS RUN OF S0007. 14-1322 -11H00M JBFX STM WATER SYSTEM PTCR CLOSEOUT WSSA (HOLDING) 111 COMPLETE. SU72497 NOT PERFORMED ______ 450 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT FOUR STEPS IF FLAME CELLS REMAIN PRESSURIZED. 14-1323 JBAC STM PERSONNEL ON SITE FOR FLAME HVAA CELL CLOSEOUT AND PRESSURIZATION. REQUEST SAFETY CLEAR NONESSENTIAL PERSONNEL AT THIS TIME AND MEET HVAC PERSONNEL AT ENTRANCE TO WEST SIDE OF TUNNEL AT PAD A/B. NOT PERFORMED ______ 14-1324 STM NTD REQUEST SFOC SAFETY CLEAR 232 NONESSENTIAL PERSONNEL FROM EAST NTD *SCC AND WEST CATACOMBS, EAST-WEST PIPE *SCC *PSE TUNNEL AND NORTH-SOUTH CABLE NET TUNNEL FOR CLOSEOUT/PRESSURIZATION 105 OF EAST/WEST FLAME CELLS. INSTALL SAFETY ROPES/SIGNS. REQUEST SAFETY CONCURRENCE TO PROCEED. ESSENTIAL PERSONNEL ------------------- GSS SFOC NASA --- ---- ---- TECH 2 ENG 1 SAFETY 1 1 NOT PERFORMED ______ 14-1325 *PSE *SCC ALL NONESSENTIAL PERSONNEL CLEAR NET OF EAST AND WEST CATACOMBS, EAST/ 105 WEST PIPE TUNNEL AND NORTH/SOUTH *SCC NTD CABLE TUNNEL. SAFETY ROPES/SIGNS 232 HAVE BEEN INSTALLED. YOU HAVE NTD STM SAFETY CONCURRENCE TO PROCEED WITH FLAME CELL CLOSEOUT AND PRESSURIZATION. NOT PERFORMED ______ 451 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING FOLLOWING STEP IS HAZARDOUS DUE TO CLOSEOUT/PRESSURIZATION OF EAST AND WEST FLAME CELL. CLOSEOUT FLAME CELLS/PIPE TUNNEL -------------------------------- NOTE PERFORM NEXT STEP AS DETERMINED BY TEST TEAM. 14-1326 STM JBAC PERFORM CLOSEOUT/PRESSURIZATION HVAA 111 OF EAST AND WEST FLAME CELL PER OMI M3034. NOT PERFORMED ______ ACTIVATE SLIDEWIRE BUNKER TLV ----------------------------- DETECTORS --------- 14-1327 -11H00M *SCC *PSE LOCATE PORTABLE O2 CONCENTRATION (HOLDING) NET METER MMH TLV DETECTOR, S70-0547, 105 AND N204 TLV DETECTOR, S70-0548, WITH BATTERY CHARGER CABLES IN SLIDEWIRE BUNKER. PLUG IN BATTERY CHARGERS, TURN ON EQUIPMENT, AND ZERO METERS. 14-1328 *PSE *SCC O2 METER, MMH TLV DETECTOR AND NET N204 TLV DETECTOR LOCATED AND 105 BATTERY CHARGERS HAVE BEEN TURNED ON. METERS HAVE BEEN ZEROED. 14-1329 OTC *PAD PERFORM CREW MODULE EMERGENCY 132 LIGHTING REMOVAL PER JC V66-90002 - EMERGENCY ALARMS AND LIGHTING, CREW COMPARTMENT, REMOVAL. 14-1330 *PAD OTC CREW MODULE EMERGENCY LIGHTING 132 REMOVAL COMPLETE. 452 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET LOX VENTING AND OPENING OF ----------------------------- PD1 (MPS LO2 17 IN. DISC) ------------------------- 14-1331 TBC CLOX PERFORM FOLLOWING PER OMI G3151 SU72454 136 (OR G3155 IF PERFORMING SCRUB TURNAROUND). 1. ET PREPARATIONS FOR LOADING. 2. OPEN MPS LO2 17 IN. FEED DISC VLV (PD1). 14-1332 -11H00M CLOX TBC VERIFY WIND SPEED FORECAST FOR (HOLDING) 136 60 FT LEVEL AT PAD WEATHER TOWER WILL NOT EXCEED 60 KNOTS FOR NEXT HOUR. 14-1333 CLOX TBC REQUEST CMPL SWITCH TO OIS CH 156 136 TO SUPPORT G3151/G3155 ET PREPS TBC OTC FOR LOADING. REPORT TO CLOX. 132 NOTE DO NOT PERFORM NEXT THREE STEPS IF GOX VENT ARM RETRACTED. 14-1334 CLOX TBC ET LOX TANK WILL BE VENTED SU72520 136 MOMENTARILY. VERIFY GOX VENT TBC CMEC ARM CLEAR OF PERSONNEL. NOT PERFORMED ______ 14-1335 CMEC TBC GOX VENT ARM CLEAR OF PERSONNEL. 136 OK TO VENT ET LOX TANK. TBC CLOX NOT PERFORMED ______ 14-1336 TBC NTD ET LOX TANK WILL BE VENTED 232 MOMENTARILY. GOX VENT ARM NTD *SCC CLEAR OF PERSONNEL. NOT PERFORMED ______ 453 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1337 TBC NTD ATTENTION ON PAD ___: 232 NTD ET LOX TANK WILL BE VENTED PA MOMENTARILY. LOUD GN2 VENTING WILL OCCUR IN THE VICINITY OF THE ET NOSECONE. 14-1338 CMPL OTC REQUEST NO TCS PGM ACTIVE (OTHER 132 THAN MPS) DURING LO2 17 INCH DISC OTC NTD VALVE AND LATCH CYCLING. NOTIFY 232 PERSONNEL IN AFT THAT LO2 17 IN. NTD TBC DISC VALVE AND LATCH CYCLING WILL BE AUDIBLE. 14-1339 NTD OTC PROCEED WITH LO2 17 INCH DISC 232 VALVE AND LATCH CYCLING PER OTC CMPL OMI G3151. 132 14-1340 CMPL OTC LOX 17 IN. DISCONNECT IS OPEN 132 AND LATCH IS LOCKED PER G3151. OTC NTD TCS PGM ACTIVITY MAY RESUME. 232 NTD TBC OMRSD S00FA0.810-A NOTE DO NOT PERFORM NEXT TWO STEPS IF GOX VENT ARM IS RETRACTED. 14-1341 CLOX TBC ET LOX TANK VENTING COMPLETE AND 136 ET VENT VALVE CLOSED. OK TO RESUME TBC CMEC OPERATIONS ON GOX VENT ARM. NOT PERFORMED ______ 14-1342 TBC NTD ET LOX TANK VENTING OPERATIONS SU72520 232 COMPLETE. GOX VENT ARM OPEN. NTD *SCC NOT PERFORMED ______ 454 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING PRIOR TO INITIATING PREPRESS PURGE, DETERMINE WHETHER OR NOT THERE ARE PERSONNEL IN AFT FUSELAGE. IF PERSONNEL ARE IN AFT, PERFORM NEXT TWO STEPS. 14-1343 CLOX TBC ET LOX TANK WILL BE PRESSURIZED 136 MOMENTARILY. NOTIFY PERSONNEL IN TBC NTD AFT FUSELAGE THAT AUDIBLE GHE FLOW 232 WILL BE HEARD IN LOX PREPRESS LINES. NTD OTC OTC *ACM 132 NOT PERFORMED ______ 14-1344 *ACM OTC PERSONNEL IN AFT FUSELAGE HAVE BEEN 132 NOTIFIED THAT AUDIBLE GHE FLOW WILL OTC NTD BE HEARD IN LOX PREPRESS LINES. YOU 232 HAVE CONCURRENCE TO PROCEED. NTD TBC TBC CLOX 136 NOT PERFORMED ______ NOTE NEXT STEP MAY BE REPEATED FOR ET LOX TANK PRESSURE MAINTENANCE. 14-1345 CLOX TBC ATTENTION ON PAD _____: 136 TBC NTD ET LOX TANK WILL BE PRESSURIZED. 232 AUDIBLE GHE FLOW WILL BE HEARD NTD IN LOX PREPRESS LINES. PA RUN 1__________ RUN 2__________ RUN 3__________ RUN 4__________ RUN 5__________ RUN 6__________ RUN 7__________ RUN 8__________ RUN 9__________ RUN 10_________ 455 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1346 CLOX TBC ET PREPARATIONS FOR LOADING AND SU72342 136 ALL SEQUENCES OF LO2 PREPS COMPLETE PER G3151 (OR G3155 IF PERFORMING SCRUB TURNAROUND) EXCEPT STORAGE TANK PRESSURIZATION AND SUCTION LINE CHILLDOWN. LCC2 CONFIGURATION COMPLETE --------------------------- 14-1347 -11H00M LPS NTD SUPPORT OPERATION SUPPORT SETUP 2 - (HOLDING) 232 LCC2 LAUNCH SUPPORT CONFIGURATION - LPS T-11 HOUR BIH TO T+45 MINUTES COMPLETE. NOTE PERFORM NEXT STEP IF NOT PREVIOUSLY PERFORMED FOR PAYLOAD SUPPORT. 14-1348 LPS NTD SUPPORT OPERATION SUPPORT SETUP 4 - 232 LCC2 PAYLOAD SUPPORT CONFIGURATION COMPLETE. NOT PERFORMED ______ 14-1349 LPS JSDC VERIFY PCGOAL TO LCC2 RESTRICTED | 127 TO S0007 DATA ONLY. 14-1350 JYCJ GYCC SPEAKERS NO. 17 AND NO.18 ON COMM 117 EAST STAIRWELL AT PAD SURFACE GYCC STM HAVE BEEN REMOVED. CABLES HAVE 111 BEEN STORED IN BOX PROVIDED. 00H30M TO END OF HOLD --------------------- 456 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GOX VENT HOOD/ET ALIGN COMPLETE ------------------------------- 14-1351 CMEC TBC GOX VENT HOOD/ET ALIGNMENT SU72466 136 COMPLETE. LIFE SUPPORT EQUIP - COMPLETE ----------------------------- 14-1352 *SCB JSTC THE FOLLOWING IS COMPLETE: LS NET SU72511 104 1. SNAP HALYARDS FASTENED TO JSTC STM ELSA BOX LATCHES ON RSS, 111 MLP, AND BOX ON 195 FT LVL FSS. 2. LOOSE LIFE SUPPORT EQUIPMENT AND ELSA BOXES WITHOUT HOLDDOWN CABLES REMOVED FROM RSS AND MLP. 3. ORBITER AFT RESCUE EQUIPMENT REMOVED FROM RSS SIDE 2 130 FT LEVEL (50-2 ACCESS DOOR) AND REMAINING BREATHING AIRLINES FROM 130 FT LVL (50-1/2), "0" LVL MLP, 107 FT, 120 FT, AND 207 FT LEVELS OF RSS HAVE BEEN REMOVED. 4. BREATHING AIR PANEL REMOVED FROM RSS AND TAKEN TO SLIDEWIRE BUNKER, CONNECTED TO K BOTTLE MANIFOLD AND PRESSURIZED. 457 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MONITOR SHACK REMOVAL COMPLETE ------------------------------ NOTE PERFORM NEXT STEP IF ACCESS MONITOR SHACKS WERE RESTORED FOLLOWING PREVIOUS HAZARDOUS OPERATION. 14-1353 GBHE JBDY ACCESS MONITOR SHACKS REMOVED HESA NET FROM PAD SURFACE AND 130/135 FT SU72366 104 LEVEL RSS AND TETHER STATION JBDY STM REMOVED FROM PAD SURFACE. 111 STM NTD 232 NOT PERFORMED ______ 458 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- START ISSUE OF PREP AND HAZ --------------------------- BADGES ------ NOTE NEXT STEP WILL BE SCHEDULED REAL TIME SO THAT THE BADGE BOARD IS SET UP PRIOR TO SHIFT CHANGE. 14-1354 NTD OTC SET UP BADGE BOARD AT PAD ___ SU72475 232 GATE FOR FINAL CLOSE OUTS. OTC *PAD 132 *PAD *ACM NET 110 14-1355 *ACM *PAD BADGE BOARD SET UP AT PAD ___ NET GATE. 110 *PAD OTC 132 OTC NTD 232 14-1356 -11H00M NTD *ACM START ISSUING HAZARDOUS BADGES (HOLDING) NET AT PAD GATE FOR FOLLOWING TASKS: 110 1. LH2 FINAL PREPS 2. LO2 FINAL PREPS 3. CREW MODULE AND WHITE ROOM CLOSEOUT 4. FINAL OPERATIONS/SAFETY WALKDOWN 5. PTCR/ECS ROOM PRESSURIZATION 6. REMOVE S/S VALVE LOCKS 7. GVA FINAL ACTIVATION 14-1357 NTD ALL PERSONNEL SUPPORTING FINAL PA PAD CLOSEOUT OPERATIONS PICK UP HAZARDOUS BADGES AT PAD GATE. BADGES WILL BE ISSUED PER BY-NAME LIST. 459 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1358 *PAD TBC PRE-PROPELLANT LOAD INSPECTION SU72383 136 PER T6446 COMPLETE. OMRSD T09QAL.030-1 SEAL SRB TUNNEL DRAIN HOLES COMPLETE ------------------------------------ 14-1359 -11H00M PBOL *PAD SEALING OF SRB DRAIN HOLES PER SU72474 (HOLDING) *PAD TBC SRB OPERATION SUPPORT SETUP 1 136 COMPLETE. 14-1360 TBC NTD REMOVE LIFELINES INSTALLED HESD | 232 FOR SRB HPU EXHAUST DUCT PLUGS | NTD STM REMOVAL, SRB ESP LOWERING, AND | STM JBDY SEALING OR SRB DRAIN HOLES. REPORT | 111 COMPLETION. | **** RSS MOVE OPERATIONS **** ----------------------------- NOTE REFER TO S0007 BAR CHART FOR ACTUAL TIMELINE OF ACTIVITIES. RSS PREPS FOR MOVE TO PARK POSITION ----------------------------------- NOTE THE NEXT EIGHT STEPS WILL BE PERFORMED FIVE HOURS PRIOR TO RSS ROTATION. 14-1361 STM NTD VERIFY FOLLOWING: 232 NTD *SCC 1. PERSONNEL AVAILABLE TO *SCC *PSE CLEAR CONTROL AREA AND NET ESTABLISH AND MAINTAIN AN 105 ACCESS CONTROL SYSTEM TO HAZARDOUS AREA FOR DURATION OF THIS TEST. 2. SAFETY READY TO SUPPORT AN ENGINEERING PRE-ROTATION WALKDOWN. 460 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1362 *PSE *SCC SAFETY READY TO SUPPORT ENGINEERING NET PRE-WALKDOWN AND CLEAR CONTROL AREA. 105 *SCC NTD 232 NTD STM 14-1363 STM NTD VERIFY PERSONNEL AVAILABLE AND READY 232 TO SUPPORT A2203.002. NTD CMQC *SCC OTC TBC 14-1364 STM JSTC REMOVE LODALS FROM PAD SURFACE RGR 111 AND PTCR AREA. SU72358 JSTC WCRG NET 201 14-1365 -11H00M NTD STM PERFORM PREPS FOR RSS MOVE TO SU72484 (HOLDING) 232 OTC PARK POSITION PER OMI A2203.002. TBC (5 HRS) OTC *PAD 132 14-1366 STM QBSE PERFORM PREPS FOR RSS MOVE TO STE NET PARK POSITION PER OMI A2203.002. JSTC 104 (5 HRS) (M3094) (Q3451) PWRB 111 JSTC PWRA | JBEP PNSA | JBDY CDPA HESD 14-1367 OTC CCSE RSS MOVE PREPS ARE COMMENCING, 132 MOMENTARY SIGNAL LOSS MAY OCCUR. 461 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1368 OTC OAFM PERFORM FOLLOWING: 132 1. ENGINEERING VERIFY CUMULATIVE AVERAGE RELATIVE HUMIDITY DURING FLOW AND WITHIN PLB INTERSTITIAL AREA DURING TIME RSS HAS BEEN POSITIONED WITH PCR DOCK SEALS INFLATED DOES NOT EXCEED 45 PERCENT AVERAGE. 2. REFERENCE S0007 VL2 FIGURE 11, ENGINEERING REVIEW OPF, VAB, AND PCR DAYS TO VERIFY PLB MOISTURE CONTENT LESS THEN 61 PERCENT SATURATION. SFOC AIRFRAME ENGINEER __________ (1-7023 OV-102) (1-7019 OV-103) (1-7015 OV-104) (1-7011 OV-105) OMRSD V30C00.010 ENGINEERING REQUIREMENTS SATISFACTION ------------------------------------- 14-1369 NTD CMQC VERIFY ENGINEERING REQUIREMENTS SU72440 232 SATISFACTION (PAD FLOW THRU CTS) HAS BEEN SIGNED BY SFOC AND NASA ENGINEERING AND SUBMITTED TO QUALITY PRIOR TO START OF RSS ROTATION. QV:_____ 14-1370 -11H00M OTC CMQC VERIFY ORBITER EXTERNAL TIR LOG SU72442 (HOLDING) 132 CLOSED LESS ITEMS IDENTIFIED IN CMQC PQCG ORBITER OPERATION SUPPORT SETUP 20. 1. RAIN GUTTER ABOVE HATCH 2. SIDE HATCH WINDOW COVER 3. HATCH SEAL PROTECTOR QV:_____ 462 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1371 NTD CMQC VERIFY APPENDIX K ITEMS CONSTRAINING 232 RSS ROTATION COMPLETE. 14-1372 OTC CMQC VERIFY ORBITER OPERATION SUPPORT SU72464 132 SETUP 2, PART A AND B, COMPLETE PRIOR TO RSS ROTATION. 14-1373 TBC CMQC VERIFY ET PRE-OPERATION SETUP 6 - 136 PAD FIRE DETECTOR ALIGNMENT COMPLETE OR NOT PERFORMED. SOUND SUPPRESSION TRICKLE FLOW ------------------------------ SYSTEM ACTIVATION COMPLETE -------------------------- NOTE PERFORM NEXT STEP IF SS TRICKLE FLOW SYSTEM ACTIVATION WAS REQUIRED FOLLOWING ORBITER ESP LOWERING OR FOR SCRUB TURNAROUND. 14-1374 JBWC STM ACTIVATION OF SS TRICKLE FLOW WSSA 111 SYSTEM COMPLETE. SU72414 NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF PERFORMING SCRUB TURNAROUND AND SYSTEM HAS REMAINED CONFIGURED. PTCR/PAD WASHDOWN SYSTEMS ------------------------- CLOSEOUT COMPLETE ----------------- 14-1375 JBFX STM PTCR/PAD WASHDOWN SYSTEMS WSSA 111 CLOSEOUT COMPLETE. SU72481 STM NTD 232 NOT PERFORMED ______ 463 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OIS UNIT REMOVAL STATUS ----------------------- 14-1376 -11H00M JYCD GYCC ALL LISTED OIS UNITS HAVE BEEN COMM (HOLDING) 117 REMOVED FROM PAD SURFACE AND PNSA GYCC STM DISCONNECTED CABLES REMOVED OR JBPN SECURED. ALL DISCONNECTED OIS 111 BOX PURGE LINES HAVE BEEN STM NTD REMOVED OR SECURED BY GSS. 232 1. PAD A SURFACE STA 116-0A LOX TOWER 75 FT LEVEL N.W. CORNER OF STAIRWELL 117-73 LH2 TOWER 75 FT LEVEL N.W. CORNER OF STAIRWELL 116-73 PNEUMATIC TOWER TOP LEVEL 116-45 EAST PAD SLOPE AT PEDESTAL LH2 LINES 118-72 EAST SIDE 119-69 INDUSTRIAL WATER PLATFORM NOT PERFORMED ______ SS1 2. PAD B SURFACE STA 121-48 LOX TOWER 123-09 PNEUMATIC TOWER 122-28 LH2 TOWER 121-50 EAST PAD SLOPE AT LH2 LINES 123-4A EAST SIDE 123-48 INDUSTRIAL WATER PLATFORM NOT PERFORMED ______ SS2 14-1377 STM GBHE INSTALL LIFELINES REQUIRED TO HESD NET SUPPORT MLP HANDRAIL REMOVAL FROM 104 AROUND SRB FLAME HOLES. (SPIDER 50) 464 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RSS PRE-ROTATION WALKDOWN ------------------------- NOTE PERFORM NEXT THREE STEPS TWO HOURS PRIOR TO RSS ROTATION. 14-1378 NTD OTC VERIFY OAA IN FULL EXTENDED 232 POSITION FOR RSS ROTATION. 14-1379 NTD ATTENTION ON PAD ______: PA ALL PERSONNEL SUPPORTING RSS ENGINEERING PRE-ROTATION WALKDOWN REPORT TO PAD SITE MANAGER AT BASE OF FSS IN ______ MINUTES. 14-1380 STM NTD HAVE WALKDOWN PERSONNEL REPORT STSA | 232 TO PAD SITE MANAGER (PSTM) SU72491 111 PSTM AT BASE OF FSS FOR ENGINEERING NET QBSE PRE-ROTATION WALKDOWN IN ______ 104 MINUTES. NTD OTC 232 TBC *SCC *SCC *PSE NET 105 NOTE PERFORM NEXT FIVE STEPS ONE HOUR PRIOR TO RSS MOVE FIRST MOTION. 14-1381 -11H00M NTD OTC ATTENTION ON PAD ___: (HOLDING) 232 STM PA ALL RSS OBSERVERS SUPPORTING RSS MOVE REPORT IN ON CH 116 IN 30 MINUTES FOR RSS PRE-MOVE BRIEFING AND OBSERVER COMM CHECK. 465 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE IF NEXT STEP TO BE PERFORMED AT PAD A, J-BOSC SUPPORT NOT REQUIRED. 14-1382 STM NTD HAVE ALL RSS ROTATION OBSERVERS ELEC 232 REPORT ON STATION ON OIS CH 116 STSA | 111 JSTC IN 30 MINUTES FOR COMM CHECK AND WSSA JBFX BRIEFING PER OMI A2203.002. SU72448 116 QBSE SU72485 NTD OTC 232 JSTC JSEP 114 JBPN 14-1383 OTC *PAD VERIFY TILE REPAIR TECHS AND SU72447 132 ENGINEER ON SITE WITH APPROPRIATE REPAIR MATERIALS FOR TILE REPAIR DURING RSS MOVE. WARNING LOX AND LH2 TSM'S ARE ARMED FOR LAUNCH. PERSONNEL MUST REMAIN CLEAR OF TSM'S LANYARDS CARRIERS OR LINKS. 14-1384 OTC *PAD PROVIDE TSM OBSERVERS TO ENSURE 132 NON CONTACT WITH TSM (LOX AND LH2) LANYARDS, CARRIERS OR LINKS. 14-1385 *PAD OTC TSM OBSERVERS ON STATION. 132 466 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RSS MOVE WEATHER BRIEFING ------------------------- CAUTION WEATHER CONDITIONS MUST BE CONSIDERED BEFORE MOVING RSS AS SSV WILL BE EXPOSED TO ENVIRONMENT AFTER ROTATION. 14-1386 -11H00M NTD STM REQUEST CURRENT WEATHER AND (HOLDING) 232 FORECAST FOR RSS MOVE. 14-1387 STM JBDY REQUEST CURRENT WEATHER AND FORECAST 111 FROM CAPE WEATHER IN PREPARATION FOR RSS MOVE. 14-1388 JBDY *WEA TIME OF FORECAST:__________ 231 111 STM PROBABILITY OF PRECIPITATION:__________ STM NTD 232 PROBABILITY OF LIGHTNING WITHIN 5 NM: _______ PROBABILITY OF STEADY-STATE 60 FOOT PAD WINDS GREATER THAN 40 KNOTS:__________ 60 FOOT PAD WIND FORECAST: DIRECTION______; SPEED______; PEAK______ TEMPERATURE__________ CONSTRAINTS: 1. STEADY-STATE WIND GREATER THAN 40 KNOTS 2. LIGHTNING WITHIN 5 NM 3. FORECAST LIGHTNING WITHIN 5 NM > 20% 467 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RSS PREPS FOR MOVE TO --------------------- PARK POSITION COMPLETE ---------------------- 14-1389 *PAD OTC RSS PREPS FOR MOVE COMPLETE. 132 136 TBC 14-1390 QBSE STM RSS PREPS FOR MOVE TO PARK STSA | 116 POSITION COMPLETE. JSTC JSTC PWR JBEP SU72484 JBDY PNSA | JBPN | 111 STM NTD 232 14-1391 NTD STM PERFORM CALL TO STATIONS FOR RSS 232 MOVE TO PARK POSITION PER OMI A2203.002. RSS MOVE CLEAR -------------- WARNING SFOC SAFETY SIGNS WILL BE REMOVED ONLY (BY SFOC SAFETY) IF GN2 IS NOT FLOWING AND AIR PURGE IS ON. REMOVAL IS TO GAIN ACCESS FOR THE RSS MOVE. SAFETY SIGNS MUST BE INSTALLED ON RSS IF ROTATION TO PARK POSITION OCCURS DURING GN2 FLOW TO THE ORBITER. 14-1392 -11H00M NTD OTC VERIFY READY TO PROCEED WITH RSS SU72445 (HOLDING) 232 TBC MOVE TO PARK POSITION. SU72524 PTC STM 468 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1393 STM NTD READY TO PROCEED WITH RSS ROTATION. 232 REQUEST CONCURRENCE TO PROCEED. NTD *SCC 14-1394 -11H00M STM QBSE CLEAR NONESSENTIAL PERSONNEL FROM (HOLDING) AREA UNDER AND AROUND RSS AND RSS MOVE PATH FOR RSS ROTATE TO PARK POSITION. ESSENTIAL PERSONNEL ------------------- GSS ORB NASA SFOC --- --- ---- ---- SUPVR/ENG 4 2 2 TECH 37 26 4 QUALITY 1 1 1 SAFETY 1 1 TE-FAC 4 14-1395 -11H00M NTD ATTENTION ON PAD ___: (HOLDING) PA 232 ALL NONESSENTIAL PERSONNEL CLEAR AREAS AROUND AND UNDER ROTATING SERVICE STRUCTURE FOR RSS MOVE. PERSONNEL ACCESS BETWEEN FSS AND RSS WILL BE AT FSS 95 FT/RSS 107 FT CROSSOVER. DO NOT CROSS OVER OR REMOVE SAFETY CHAINS AT OTHER LEVELS. RSS MOVE TO PARK POSITION ------------------------- 14-1396 QBSE STM NONESSENTIAL PERSONNEL CLEAR OF SU72445 111 AREA UNDER AND AROUND RSS AND STM NTD RSS MOVE PATH. YOU HAVE SAFETY 232 CONCURRENCE TO ROTATE RSS. NTD *SCC 14-1397 *SCC NTD YOU HAVE SAFETY CONCURRENCE TO 232 PROCEED WITH RSS ROTATION. NTD STM STM QBSE 469 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1398 STM QBSE BRIEF PERSONNEL ON HAZARDS THAT STSA | 116 WILL BE PRESENT AND APPLICABLE SU72451 SEQUENCES OF APPENDIX Z. 14-1399 -11H00M STM JYVR START VIDEO RECORDING OF OTV COMM (HOLDING) 138 CAMERAS 001/101 AND 043/143. (SEE STM FIG 4) 14-1400 STM NTD REQUEST ALL TESTING IN VICINITY COMM 232 OF RSS BE DEFERRED DURING 111 PSTM CRITICAL ROTATION AROUND LAUNCH GYCC VEHICLE (ESPECIALLY TESTING THAT NTD OTC PRODUCES LOUD NOISES IN VICINITY). 232 TBC 470 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING EXTREME CAUTION MUST BE UTILIZED. TSM'S ARE ARMED FOR LAUNCH. CLEANING PERSONNEL MUST REMAIN CLEAR OF DROP WEIGHT LANYARDS. COORDINATE RSS STOP AND START ROTATION WITH QBSE ON CH 116. PERSONNEL SHALL MOVE FROM RSS TO TOP OF TSM'S AND BE TETHERED TO THE RSS WITH SAFETY BELT OR HARNESS SHORT ENOUGH TO PREVENT CONTACT WITH TSM DROPWEIGHT LANYARDS. HAZARDOUS STEPS FOLLOW DUE TO MOVEMENT OF RSS. NOTE RSS ROTATION TO PARK WILL BE INTERRUPTED FOR CLEANING TOP OF TSM'S, REMOVING INERTIAL REELS, AND TPS INSPECTION. CLEANING AND TPS OBSERVERS WILL COMMAND QBSE TO STOP AND START ROTATION ON CH 116 AS RSS CLEARS TSM'S. 14-1401 -11H00M NTD STM SAFETY CLEARS ESTABLISHED. STSA | (HOLDING) 232 MOVE RSS TO PARK POSITION SU72489 STM QBSE PER OMI A2203.002 (1 HR) SU72452 116 SU72453 SU72486 471 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RSS MOVE TO PARK COMPLETE ------------------------- 14-1402 -11H00M QBSE STM RSS MOVE OPERATIONS COMPLETE. STSA | (HOLDING) 116 (A2203) CONTINUE POST RSS SU72492 STM NTD ROTATION SECURING. (M3094) SU72452 232 NTD OTC *SCC TBC NOTE HAZARDOUS STEPS DUE TO MOVEMENT OF RSS COMPLETE. 14-1403 STM QBSE PERFORM POST OPERATION INSPECTION 116 PER OMI A2203.002 AND VERIFY CONCURRENCE TO OPEN CONTROL AREA FOR CONTROLLED WORK. 1. SAFETY HANDRAILS AND CHAINS ARE IN PLACE. 2. INSPECT RSS AND ASSOC OPERATIONAL AREA TO VERIFY EQUIP AND AREA HAVE BEEN SECURED. 3. REMOVE BARRICADES, ROPES AND WARNING SIGNS THAT ARE NOT REQUIRED. 4. SAFETY CONCURRENCE TO OPEN RSS ROTATION CONTROL AREA FOR CONTROLLED WORK. 14-1404 QBSE STM POST OPERATION INSPECTION SU72524 116 COMPLETE. REQUEST SAFETY STM NTD CONCURRENCE TO OPEN RSS ROTATION 232 CONTROL AREAS FOR CONTROLLED WORK. NTD *SCC 14-1405 *SCC NTD YOU HAVE SAFETY CONCURRENCE TO 232 OPEN RSS CONTROL AREA FOR CONTROLLED NTD STM WORK. STM QBSE 116 472 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1406 STM JYVR STOP VIDEO RECORDINGS OF OTV COMM 138 CAMERAS 001/101 AND 043/143. NOTE PERFORM NEXT STEP IF EQUIPMENT INSTALLED. 14-1407 STM JBEP REMOVE ALL TEMPORARY ELECTRICAL PWRA | 111 JBPN EQUIPMENT, INCLUDING PORTABLE PWRB LIGHT BANKS, FROM ZERO LEVEL | OF MLP. VERIFY ALL MLP ZERO LEVEL ELECTRICAL OUTLETS HAVE COVERS IN PLACE AND COVERS SECURELY FASTENED. GSS PNEUMATICS REMOVE PURGE FLEXHOSES ON MLP. GSS T:______ PNSA T:______ PWRB NOT PERFORMED ______ 14-1408 STM VEEE SECURE POWER TO RSS ELEVATOR CDPD NET PER OMI Q3018. REPORT COMPLETION. 104 MLP HANDRAIL REMOVAL -------------------- 14-1409 STM NTD REQUEST SAFETY CONCURRENCE TO SU72525 232 REMOVE HANDRAILS FROM AROUND NTD *SCC MLP FLAME HOLES. *SCC *PSE NET 105 14-1410 *SCC NTD VERIFY SRB AFT SKIRT GN2 PURGE 232 SECURED. NTD TBC TBC CBHY 136 473 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1411 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO NET REMOVE FLAME HOLE HANDRAILS FROM 105 MLP. *SCC NTD 232 NTD STM 14-1412 NTD OTC ATTENTION ON PAD _____: 232 TBC PA STM ALL PROTECTIVE BARRIERS ARE BEING REMOVED FROM FLAME HOLES OF MLP. CAUTION SHOULD BE EXERCISED AND ALL PERSONNEL MUST STAND AT LEAST 6 FT CLEAR OF FLAME HOLES AND UNPROTECTED EDGES. 14-1413 OTC *PAD VERIFY OIC ON MLP ZERO LEVEL TO 132 COORDINATE MLP ZERO LEVEL ACCESS. 14-1414 STM JBDY PROVIDE TRUCK AND MOBILE CRANE HESA 111 FOR REMOVAL OF MLP HANDRAILS JBDY GBHE (Q3205). NET 104 14-1415 NTD STM PERFORM FOLLOWING: SU72513 232 STM QBSE 1. REMOVE HANDRAILS FROM STSA | NET AROUND MLP FLAME HOLES PER 104 OMI M3083. REPORT COMPLETION. 111 JBDY NET 2. LOWER HANDRAILS FROM MLP TO HESA 104 FLATBED ON PAD SURFACE. T:______ 474 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT TWO CONTINGENCY STEPS IF HANDRAILS WERE REMOVED FROM MLP USING MOBILE CRANE. 14-1416 STM NTD UNABLE TO REMOVE HANDRAILS 232 FROM MLP USING MOBILE CRANE. NTD *SCC WILL STOW HANDRAILS ON FSS *SCC *PSE 95 FT LEVEL. NET 105 NOT PERFORMED ______ 14-1417 STM QBSE STOW HANDRAIL ON FSS 95 FT STSA | NET LEVEL PER OMI M3083. REPORT 104 COMPLETION. T:______ NOT PERFORMED ______ 14-1418 STM QBSE PERFORM AREA FOD INSPECTION STSA | NET AND CLEAN UP AROUND REMOVED SU72514 104 HANDRAILS PER OMI M3083. 14-1419 STM GBHE REMOVE LIFELINES INSTALLED FOR HESD NET HANDRAIL REMOVAL FOR AROUND 104 MLP FLAME HOLES. 14-1420 GBHE STM LIFELINES INSTALLED FOR HANDRAIL HESD NET REMOVAL HAVE BEEN REMOVED. 104 475 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE REMOVE ELSA BOXES FROM FSS 95 FT LEVEL AND EAST PAD APRON AFTER MLP SSME FLAME HOLE HANDRAILS REMOVED. 14-1421 STM JSTC MLP SSME FLAME HOLE HANDRAIL LS 111 REMOVAL COMPLETE. SU72513 JSTC *SCB SU72517 | NET 1. REMOVE ELSA BOXES ON ALL 104 LEVELS OF FSS EXCEPT ONE ELSA BOX ON 195 FT LVL. VERIFY BOX LOCATED ACROSS FROM ELEVATOR DOOR (SECURED TO FLOOR). REMOVE ELSA BOX FROM EAST PAD APRON. 2. VERIFY LIFE SUPPORT EQUIPMENT IN FSS WHITE ROOM. 14-1422 STM JBEP NOTIFY SPECIAL POWER TECHS PWRA | 111 (1-0702) TO CONFIGURE PAD WHITE SU72498 | ROOM/CREW CABIN ODMS FOR LAUNCH | PER OMI M3088. REPORT COMPLETION. NOTE PERFORM NEXT STEP IF MLP LO2 AND LH2 TSM ODMS UNITS WERE REACTIVATED FOR SCRUB TURNAROUND. 14-1423 STM JBEP SPECIAL POWER TECHS CONFIGURE PWRA | 111 MLP___ LH2 AND LO2 TSM ODMS FOR | LAUNCH PER OMI M3088. REPORT COMPLETION. NOT PERFORMED ______ 476 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TUBE BANK OPS ------------- 14-1424 STM JBPN DISCONNECT B/A TUBE BANK FROM PNSA 111 CABIN AIR SYSTEM. PLACE SU72504 CABIN AIR BOTTLES ON LINE. (M3067) (1 HR) 14-1425 STM JSTC REMOVE DISCONNECTED B/A TUBE PN 111 BANK FROM CABIN AIR BATTERY JSTC GSPS AREA. 114 HOLDING TANK CONFIG FOR LAUNCH ------------------------------ NOTE IN NEXT STEP, IF AVAILABLE CAPACITY IS LESS THAN 400,000 GALLONS, ADVISE FFO. 14-1426 STM QBSE OBTAIN HOLDING TANK DEPTH STSA | NET MEASUREMENTS (OMI M3175). SU72507 104 REPORT DATA. EAST TANK DEPTH __________ IN. BD AVAILABLE CAPACITY __________ GAL DATE__________ TIME__________ WEST TANK DEPTH __________ IN. BD AVAILABLE CAPACITY __________ GAL DATE__________ TIME__________ 14-1427 STM QBSE POSITION EAST AND WEST HOLDING STSA | NET TANK GATES TO PREVENT WATER SU72507 104 FROM ENTERING DRAINAGE DITCHES AND PERMIT WATER TO ENTER HOLDING TANKS (OMI M3175). REMOVE HAND CRANKS AND SCREW COVERS. REPORT COMPLETION. 477 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GOX VENT SYSTEM FINAL ACTIVATION -------------------------------- 14-1428 NTD TBC PERFORM GOX VENT SYSTEM FINAL SU72571 232 ACTIVATION FOR LOX LOADING PER TBC CMEC OMI G2158 GVA HOOD GN2 FLOW ----------------- 14-1429 CMEC TBC READY TO PROCEED WITH GN2 FLOW 136 *PAD TO HOOD PER OMI G2158. TBC NTD 232 NTD *SCC 14-1430 CMEC PMEA CLEAR ALL NONESSENTIAL PERSONNEL 186 FROM GVA FOR GN2 FLOW TO HOOD. ESSENTIAL PERSONNEL ------------------- SFOC ---- PME4 TECH 1 PQC1 QC 1 SAFETY 1 14-1431 NTD ATTENTION ON PAD ___: PA GOX VENT ARM HEATED PURGE WILL BE ACTIVATED MOMENTARILY. NONESSENTIAL PERSONNEL CLEAR GOX VENT ARM. 478 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING HAZARDOUS OPERATIONS FOLLOW DUE TO LARGE VOLUMES OF GN2. DURING GN2 FLOW GOX VENT HOOD ACCESS DOORS AND WINDOW WILL NOT BE OPENED. 14-1432 PMEA CMEC ALL NONESSENTIAL PERSONNEL SU72607 186 CLEARED FROM GVA FOR GN2 FLOW CMEC TBC TO HOOD. HAZARDOUS GN2 FLOW 136 *PAD COMMENCING. TBC NTD 232 NTD *SCC 14-1433 TBC CMEC BRIEF PERSONNEL ON HAZARDS THAT 136 WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. 14-1434 GSPN JSTC INITIATION OF LPGN2 FLOW FOR PNU 114 GOX VENT HOOD PURGE COMPLETE. JSTC STM 111 STM NTD 232 NTD TBC 14-1435 STM QBSE VERIFY NORTH PERIMETER ROAD STE NET CULVERT VALVE(S) OPEN. 104 479 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TOP-OFF WATER TROUGHS --------------------- 14-1436 -11H00M STM QBSE PERFORM WATER TROUGH INSPECTION. STSA | (HOLDING) NET SU72510 104 1. INSPECT WATER TROUGHS ON MLP. 2. IF FILL LEVEL OF ONE OR MORE BAGS BELOW REQUIRED FILL LEVEL, PERFORM LEAK INSPECTION TO DETERMINE LOCATION AND EXTENT OF LEAKAGE. 3. REPLACE ANY WATER BAG THAT APPEARS TO HAVE A SIGNFICANT LEAK PER OMI M3083. 4. TOP OFF ALL WATER TROUGHS. ESSENTIAL PERSONNEL ------------------- NASA GSS ---- --- SUPER/ENG 1 2 TECH 4 QUALITY 1 ECS TRANSFER AND ECS PREP FOR ----------------------------- AIR TO GN2 CHANGEOVER --------------------- 14-1437 OTC NTD BEGINNING ECS INITIAL PREPS. SU72544 232 14-1438 OTC CPVD PERFORM "CONTROL STATION 132 TRANSFER - PAD TO FIRING ROOM" AND "ECS PREPARATIONS FOR AIR TO GN2 CHANGEOVER; OPTION A - INITIAL PREPS" PER OMI V1122 MANUAL GN2 ISOLATION VALVES TO REMAIN CLOSED AND LOCKED. (1 HR 45 MIN) RT OMI LOG NO.__________ 480 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1439 OTC *PAD PERFORM POST OPERATION INSTRUCTION 1 - 132 RSS MOVE TO PARK POSITION PER OMI A2203.002. 14-1440 OTC PPVM THERMAL CONDITION PCR TO 73-75 DEG F 132 PER OMI V1122 AND SHUT OFF SIDE STREAM FILTER PER OMI V6C68. REMOVE OIS UNITS - ------------------ MLP, FSS AND RSS PIVOT ---------------------- NOTE PERFORM NEXT TWO STEPS UPON COMPLETION OF TSM CLOSEOUT, RSS RETRACT OPERATIONS, AND SRB DRAIN LINE/PLUG REMOVALS. UCOM/GSS TECHS MEET AT BASE OF FSS ELEVATOR. 14-1441 -11H00M NTD STM 1. UCOM REMOVE ALL PORTABLE COMM (HOLDING) 232 OIS UNITS FROM MLP ZERO PNSA STM GYCC LEVEL. INSTALL CAPS ON SU72502 111 JBPN GOOSENECK CABLE CONNECTORS GYCC JYCD (30 MIN). GSS REMOVE PURGE 117 FLEXHOSES ON MLP. UCOM T:______ SS1 GSS T:______ SS1 481 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1441 2. UCOM REMOVE FOLLOWING OIS CON'T STATIONS FROM LAUNCH PAD IN USE AND SECURE CABLES. GSS SECURE FLEXHOSES ON FSS AND RSS PIVOT UPON REMOVAL OF OIS BOXES. PAD A: STA 116-4A FSS 95 FT LEVEL 117-0E FSS 95 FT LEVEL 118-60 FSS 115 FT LEVEL 117-03 FSS 115 FT LEVEL 116-29 FSS 135 FT LEVEL 118-48 FSS 135 FT LEVEL 117-4F RSS PIVOT (PAD A SURFACE) PAD B: STA 120-05 FSS 95 FT LEVEL 123-64 FSS 95 FT LEVEL 122-44 FSS 115 FT LEVEL 120-4E FSS 115 FT LEVEL 120-52 FSS 135 FT LEVEL 120-46 FSS 135 FT LEVEL 121-0A RSS PIVOT (PAD B SURFACE) UCOM T:______ SS2 GSS T:______ SS2 482 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1441 3. UCOM REMOVE FOLLOWING OIS CON'T UNITS FROM LAUNCH PAD IN USE AND ENSURE DISCONNECTED CABLES ARE REMOVED OR SECURED TO STRUCTURE WITH BLAST TAPE. GSS SECURE DISCONNECTED PURGE LINES FIRMLY IN PLACE WITH BLAST TAPE. (30 MIN) RSS 130 FT LEVEL PAD A STA 119-2A 119-64 PAD B STA 122-2D 121-4C UCOM T:______ SS3 GSS T:______ SS3 483 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OIS UNIT REMOVAL STATUS ----------------------- 14-1442 JYCD GYCC OIS UNITS/STATIONS HAVE BEEN COMM 117 REMOVED AT LAUNCH PAD IN USE SU72502 GYCC STM FROM FOLLOWING LOCATIONS 111 STM NTD 1. ALL UNITS ON MLP ZERO LEVEL 232 HAVE BEEN REMOVED AND CAPS INSTALLED ON GOOSENECK CABLE CONNECTORS. 2. PAD A: STA 116-4A FSS 95 FT LEVEL 117-0E FSS 95 FT LEVEL 118-60 FSS 115 FT LEVEL 117-03 FSS 115 FT LEVEL 116-29 FSS 135 FT LEVEL 118-48 FSS 135 FT LEVEL 117-4F RSS PIVOT (PAD A SURFACE) PAD B: STA 120-05 FSS 95 FT LEVEL 123-64 FSS 95 FT LEVEL 122-44 FSS 115 FT LEVEL 120-4E FSS 115 FT LEVEL 120-52 FSS 135 FT LEVEL 120-46 FSS 135 FT LEVEL 121-0A RSS PIVOT (PAD B SURFACE) 3. PAD A STA 119-2A 119-64 PAD B STA 122-2D 121-4C STA CABLES HAVE BEEN SECURED OR PLACED IN PULL BOXES 484 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT STEP UNTIL RSS MOVE COMPLETE. CLOSE DOORS OF EXPLOSION PROOF PHONES ------------------------------------- 14-1443 -11H00M NTD STM CLOSE DOORS OF FOLLOWING LISTED COMM (HOLDING) 232 EXPLOSION PROOF TELEPHONES SU72495 STM GYCC ON FSS AND RSS. (45 MIN) 111 GYCC JYCJ 117 FSS PAD SURFACE BY ELEVATOR FSS 75 FT LEVEL SIDE 3 FSS 95 FT LEVEL BY ELEVATOR (PAD B ONLY) FSS 115 FT LEVEL BY ELEVATOR (PAD B ONLY) FSS 135 FT LEVEL FSS 155 FT LEVEL SIDE 2 FSS 215 FT LEVEL REST ROOM FSS 255 FT LEVEL SIDE 4 RSS 130 FT 7 IN. LEVEL SIDE 4 (PAD B ONLY) RSS 212 FT LEVEL SIDE 3 OUTSIDE PCR HOIST ROOM WALL T:______ 14-1444 JBPN STM PURGE FLEXHOSE HAS BEEN REMOVED PNSA 111 FROM PORTABLE OIS LOCATIONS ON MLP AND RSS PIVOT AND SECURED TO STRUCTURE WITH BLAST TAPE ON FSS OIS LOCATIONS. 14-1445 NTD ATTENTION IN THE AREA: PA PERSONNEL PARTICIPATING IN FINAL TPS ENGINEERING DEBRIS WALKDOWN REPORT TO BASE OF THE FSS, PAD ___, IN 30 MINUTES. 485 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FINAL TPS DEBRIS WALKDOWN ------------------------- 14-1446 -11H00M NTD OTC PERFORM INTEGRATED OPERATION (HOLDING) 232 STM SUPPORT SETUP 3 - FINAL TPS *SCC DEBRIS INSPECTION WALKDOWN, OTC *PAD REPORT ON STATION AT PAD ____ 132 IN 30 MINUTES. STM PSTM 111 *SCC *PSE NET 105 NOTE PERFORM NEXT TWO STEPS IF DEBRIS WALKDOWN SCHEDULED DURING SOUND SUPPRESSION TANK FILL. 14-1447 -11H00M NTD STM VERIFY SOUND SUPPRESSION LOCKS (HOLDING) 232 INSTALLED, GN2 PRESSURE TO CLOSE ACTUATORS AND LOCKOUT COMMAND ON. NOT PERFORMED ______ 14-1448 NTD *SCC SOUND SUPPRESSION LOCKS INSTALLED, 232 TPS WALKDOWN PERSONNEL MAY ENTER *SCC *PSE FLAME TRENCH. NET 105 NOT PERFORMED ______ 14-1449 NTD OTC YOU HAVE CONCURRENCE TO SU72459 232 PROCEED WITH DEBRIS WALKDOWN. OTC *PAD PERFORM INTEGRATED OPERATION 132 SUPPORT SETUP 3 - FINAL TPS DEBRIS WALKDOWN. (2 HR) 486 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RSS AIR HOISTS SECURING ----------------------- 14-1450 STM JCTL PERFORM FOLLOWING: CDPA 111 SU72494 JCTL PCMP 1. TAG OUT 1-TON AIR HOISTS ON RSS 130 FT LEVEL. SECURE HOISTS WITH CLAMPS AND LANYARD. INSTALL PROTECTIVE COVER ON HOISTS. T:______ SS1 2. TAG-OUT 2-TON AIR HOISTS ON RSS 107 FT LEVEL. INSTALL PROTECTIVE COVER ON PENDANT CONTROL. (1 HR) T:______ SS2 ESSENTIAL PERSONNEL ------------------- GSS --- 4 RSS AIR HOISTS SECURING COMPLETE -------------------------------- 14-1451 PCMP JCTL AIR HOISTS ON RSS 130 FT- CDPA JCTL STM 107 FT LEVEL CONFIGURED FOR 111 LAUNCH. EAST AND WEST FLAME CELLS CLOSEOUT ---------------------------------- COMPLETE -------- 14-1452 JBAC STM EAST AND WEST FLAME CELLS HVAA 111 CLOSEOUT/PRESSURIZATION COMPLETE. STM NTD 232 NOTE HAZARDOUS STEPS FOR FLAME CELL CLOSEOUT AND PRESSURIZATION COMPLETE. 487 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PTCR CLOSEOUT ------------- 14-1453 -11H00M NTD STM PERFORM PTCR CLOSEOUT PER HVAA (HOLDING) 232 OMI M3034. (1H45M) SU72499 STM JBAC 111 STANDBY IN PTCR RM 102 FOR UPPER AND LOWER BLAST DOOR CLOSURE. ESSENTIAL PERSONNEL ------------------- GSS NASA --- ---- SUPR/ ENGR 2 1 QUAL 1 TECH 2 VERIFY MLP/PAD CAMERAS READY ---------------------------- 14-1454 STM JPHO VERIFY MLP AND PAD CAMERAS SU72416 111 INSTALLED AND PHOTO OPTICAL CONTROL SYSTEM (POCS) READY TO SUPPORT. SECURING/PURGE - CAMERA ENCLOSURES ---------------------------------- 14-1455 STM JTCR VERIFY MLP AND PAD CAMERA ENCLOSURES 111 SECURED AND PURGED. 488 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET LOAD SAFETY/FACILITY/FIRE WALKDOWN ------------------------------------- NOTE MLP SIGNS SHALL NOT BE REMOVED UNTIL SAFETY VERIFIES TOTAL PAD CLEAR. ET LOAD WALKDOWN SHOULD BE PERFORMED DURING DAYLIGHT HOURS FOLLOWING RSS TO PARK. BARCHART SHALL REFLECT SCHEDULED TIME. 14-1456 NTD *PAD PERFORM INTEGRATED OPERATION FIRE 232 OTC SUPPORT SETUP 5 - ET LOAD SU72456 TBC SAFETY/FACILITY/FIRE WALKDOWN. SU72506 STM (2 HR). HAVE WALKDOWN PARTICIPANTS *SCC MEET WITH PAD LEADER AT *SCC *PSE __________ (RECORD LOCATION) NET IN 30 MINUTES. 105 OTC *PAD PARTICIPANTS 132 ------------ STM JSTC GSE OPS 111 FACILITY OPS JSTC JFIR SFOC SAFETY 114 QUALITY CONTROL FIRE INSPECTOR PAD LEADER NASA SAFETY 489 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1457 NTD ATTENTION ON PAD___. PA ALL PERSONNEL SUPPORTING ET LOAD SAFETY/FACILITY/FIRE WALKDOWN MEET WITH PAD LEADER AT ___________ (RECORD LOCATION) IN 30 MINUTES. SAFETY FACILITY/FIRE WALKDOWN ----------------------------- NASA SFOC JBOSC ---- ---- ----- *PAD 1 SAFETY 1 1 QUALITY 1 GSE OPS 1 PSTM 1 FIRE INSPECTOR 1 14-1458 NTD *SCC PERFORM INTEGRATED OPERATION SU72455 232 SUPPORT SETUP 4 - EMERGENCY SU72506 *SCC *PSE EGRESS ROUTE WALKDOWN. ADD NET ANY DISCREPANCIES TO APPENDIX K 105 AND NOTIFY *PAD (1 HR). INFLATE DOCK SEALS ------------------ 14-1459 *PAD OTC INFLATE DOCK SEALS FOR LAUNCH SU72461 132 PER OMI V1122. REPORT COMPLETION. OTC PPVM RT OMI LOG NO.__________ **** RSS MOVE OPERATIONS COMPLETE **** -------------------------------------- 490 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM RSS SIDE 4 DOOR SECURING IF RSS SIDE 4 PCR EMERGENCY EGRESS DOORS REQUIRE SECURING. RSS SIDE 4 DOOR SECURING ------------------------ NOT PERFORMED ______ 14-1460 -11H00M NTD *SCC REQUEST CONCURRENCE TO BOLT (HOLDING) 232 CLOSED, RSS SIDE 4 PCR *SCC *PSE EMERGENCY EGRESS DOORS. NET 105 14-1461 *SCC NTD VERIFY NO HAZARDOUS TASKS 232 BEING PERFORMED IN PCR AND PERSONNEL ACCESS TO BE CONTROLLED. 14-1462 *PSE *SCC SAFETY VERIFY CONCURRENCE NET TO CLOSE AND BOLT, RSS SIDE 4 105 PCR EMERGENCY EGRESS DOORS. *SCC NTD 232 14-1463 NTD STM CLOSE AND BOLT RSS SIDE 4 PCR STSA | 232 EMERGENCY EGRESS DOORS (BALANCE) SU72488 STM QBSE PER OMI M3134. (1H30M) NET 104 14-1464 NTD OTC ALL RSS SIDE 4 PCR EMERGENCY 232 EGRESS DOORS WILL BE BOLTED CLOSED. 14-1465 NTD OTC REMOVE LOCKS FROM PCR EQUIPMENT 232 AIRLOCK DOOR SLIDE BOLTS AND OTC *PAD ENGAGE SLIDE BOLTS. (LOCK DOORS) 132 RETAIN SLIDE BOLT LOCKS FOR *PAD PPTS REINSTALLATION WHEN SLIDE BOLTS ARE DISENGAGED. T:______ 491 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RSS SIDE 4 PCR DOORS LOCKED --------------------------- 14-1466 QBSE STM RSS SIDE 4 PCR EMERGENCY EGRESS STSA | NET DOORS CLOSED AND BOLTED. SU72488 104 STM NTD 232 T:______ RSS SIDE 4 DOOR SECURING COMPLETE --------------------------------- ROPE/SIGN/TEMP HANDRAIL REMOVAL ------------------------------- NOTE PERFORM NEXT SIX STEPS IF TEMP HANDRAILS INSTALLED. 14-1467 STM NTD VERIFY CONCURRENCE TO REMOVE 232 ROPES AND SIGNS FROM AROUND NTD *SCC FLAME TRENCH. SAFETY WILL *SCC *PSE ENSURE ALL PERSONNEL WORKING NET WITHIN 6 FT OF FLAME TRENCH 105 ARE WEARING SAFETY HARNESS WITH LANYARD SECURED TO PERMANENT STRUCTURE. NOT PERFORMED ______ 14-1468 *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO NET PROCEED WITH ROPE, SIGN REMOVAL. 105 *SCC NTD 232 NTD STM NOT PERFORMED ______ 492 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1469 NTD OTC ATTENTION ON PAD: PA TBC 232 STM ALL PROTECTIVE BARRIERS ARE BEING REMOVED FROM AROUND FLAME TRENCH. CAUTION SHOULD BE EXERCISED AND ALL PERSONNEL MUST STAND AT LEAST 6 FT CLEAR OF FLAME TRENCH UNPROTECTED EDGES. NOT PERFORMED ______ 14-1470 STM QBSE BRIEF PERSONNEL ON HAZARDS THAT STSA | NET WILL BE PRESENT AND APPLICABLE 104 SEQUENCES OF APPENDIX Z. NOT PERFORMED ______ WARNING PERSONNEL WORKING AT UNPROTECTED HEIGHTS (DROP MORE THAN 4 FT) OUTSIDE OF GUARDRAILS/SAFETY CHAINS (WITHIN 6 FT OF AN UNGUARDED EDGE) WILL WEAR SAFETY HARNESS WITH LANYARD SECURED TO AN APPROVED TIE-OFF POINT. SUBSTANTIAL STRUCTURAL MEMBER (NO HAND RAILS) OR A PROPERLY INSTALLED LIFE LINE. 14-1471 QBSE STM PERSONNEL WORKING AT UNPROTECTED STSA | NET HEIGHTS ARE WEARING SAFETY HARNESS 104 WITH LANYARD PROPERLY SECURED. NOT PERFORMED ______ 493 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1472 STM QBSE REMOVE WIRE ROPES AND SIGNS AT STSA | NET FLAME TRENCH NORTH AND TEMPORARY SU72500 104 ROPES AND SIGNS FROM AROUND FLAME TRENCH SOUTH. STOW EQUIPMENT IN 9099 TOWER AND BOLT DOOR SECURELY. (2 HRS) ESSENTIAL PERSONNEL ------------------- GSS --- SUPER/ENG. 2 TECH 5 T:______ NOT PERFORMED ______ 14-1473 STM QBSE SECURE FSS 95 FT LEVEL TO WEST STSA | NET STAIR TOWER SECURITY GATE WITH 104 CHAIN AND HOOK. TELEPHONE LOCKOUT ----------------- NOTE PERFORM SUBSTEP TWO OF FOLLOWING STEP IF PCR TELEPHONES WERE RESTORED TO SERVICE AFTER PRSD LOAD. 14-1474 NTD STM PERFORM FOLLOWING: 232 STM GYCC 1. VERIFY PCR TELEPHONES AT COMM 111 PAD A/B ARE LOCKED OUT. GYCC JSOQ PTP 2. LOCKOUT PAD A/B PCR TELEPHONES 117 JYCJ PER OMI D3008. REPORT COMPLETION. NOT PERFORMED ______ SS2 494 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- EXPLOSION PROOF PHONE DOORS CLOSED ---------------------------------- 14-1475 -11H00M JYCJ GYCC DOORS OF EXPLOSION PROOF COMM (HOLDING) 117 TELEPHONES ON FSS AND RSS SU72495 GYCC STM HAVE BEEN CLOSED. 111 SPARE REFRIG UNIT RELOCATION COMPLETE ------------------------------------- NOTE DO NOT PERFORM NEXT STEP IF SPARE REFRIGERATION UNIT NOT PLACED ON PAD FOR CONTINGENCY USE. PERFORM NEXT STEP FOR PAD A ONLY. 14-1476 -11H00M GBHE JBDY SPARE REFRIGERATION UNIT, HESA (HOLDING) JBDY STM FLATBED TRUCK AND FORKLIFT SU72482 111 RELOCATED TO HE PARKING AREA (TO STM NTD REMAIN ON STANDBY UNTIL LAUNCH). 232 NTD OTC NOT PERFORMED ______ 14-1477 QBSE STM WATER TROUGHS INSPECTED STSA | NET AND TOPPED OFF COMPLETE. SU72510 104 OMRSD S00FA0.870 T:______ NOTE DO NOT PERFORM NEXT STEP IF PERFORMING SCRUB TURNAROUND AND SYSTEM HAS REMAINED CONFIGURED. 14-1478 STM JBFX REMOVE MLP SIDE 2 AND SIDE 4 WSSA 111 DECK MOUNTED FIREX HOSEREELS SU72505 AND ORBITER SKIN SPRAY NOZZLE PROTECTION PER OMI M3190. NOT PERFORMED ______ 495 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SECURE PAD ELEVATOR NO. 2 ------------------------- 14-1479 STM VEEE SECURE PAD HYDRAULIC ELEVATOR CDPD NET NO. 2 PER OMI Q3018. SU72490 104 ET LOAD SAF/FAC/FIRE WALKDOWN ----------------------------- (PART A) COMPLETE ----------------- 14-1480 *PAD TBC INTEGRATED OPERATION SUPPORT SU72456 136 SETUP 5 - ET LOAD SAFETY/ TBC NTD FACILITY/FIRE WALKDOWN (PART A) 232 COMPLETE. NTD *SCC TPS DEBRIS WALKDOWN COMPLETE ---------------------------- 14-1481 *PAD OTC INTEGRATED OPERATION SUPPORT SU72459 132 SETUP 3 - FINAL TPS DEBRIS OTC NTD WALKDOWN COMPLETE. 232 14-1482 *PSE *SCC INTEGRATED OPERATION SUPPORT SU72455 NET SETUP 4 - EMERGENCY EGRESS 105 ROUTE WALKDOWN COMPLETE. *SCC NTD 232 NOTE PERFORM NEXT STEP ONLY IF HOSEREELS WERE REMOVED BY THIS SEQUENCE. 14-1483 JBFX STM MLP SIDE 2 AND SIDE 4 DECK WSSA 111 MOUNTED HOSEREELS HAVE BEEN SU72505 REMOVED. NOT PERFORMED ______ 496 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OPEN SS LOCKING VALVES | ---------------------- | | 14-1484 NTD STM REMOVE PAD LOCKS AND OPEN SU72666 | 232 HYDRAULIC LOCKING VALVES. WSSA | STM JBWC REINSTALL PAD LOCKS PER | 111 OMI M3189.001. (15 MIN) | | 14-1485 JBWC STM SS LOCKING VALVES OPEN SU72666 | 111 WITH PADLOCKS INSTALLED. WSSA | STM NTD | 232 | 497 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TUBE BANK OPS COMPLETE ---------------------- 14-1486 JBPN STM BREATHING AIR TUBE BANK PNSA 111 DISCONNECTED, CABIN AIR BOTTLES SU72504 ON LINE. 14-1487 GSPS JSTC B/A TUBE BANK REMOVED FROM PN NET CABIN AIR BATTERY AREA. 104 JSTC STM 111 STM NTD 232 LAUNCH PAD TOURS ---------------- NOTE PERFORM NEXT STEP AT L-15 HOURS. TOURS MAY BE PERMITTED ABOVE PAD SLOPE AFTER THIS TIME AT THE DISCRETION OF THE NTD. 14-1488 NTD *SEC DISCONTINUE ALL TOURS INTO PAD SU72437 232 STM SLOPE. NTD MAY APPROVE EXCEPTIONS STM JBDY AS DIRECTED BY LAUNCH DIRECTOR. 111 LH2 STORAGE TANK VENT VALVE - OPEN ---------------------------------- AND FLARE STACK PREPS --------------------- NOTE PERFORM NEXT STEP A MINIMUM OF FOUR HOURS PRIOR TO PLANNED START OF LH2 LOADING. 14-1489 -11H00M NTD TBC PERFORM OPERATION SUPPORT SETUP SU72572 (HOLDING) 232 1 OF OMI G3251 - LH2 FLARE STACK SU72518 TBC CLHY PREPARATIONS AND A3306 (STORAGE 136 TANK VENT) VALVE OPENING. (30 MIN). 498 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1490 CLHY TBC ATTENTION ON PAD ___: 136 TBC NTD LH2 VENTING TO FLARE STACKS WILL 232 OCCUR MONENTARILY. NTD PA 14-1491 -11H00M CLHY TBC G3251 OPERATION SUPPORT SETUP 1 - (HOLDING) 136 LH2 FLARE STACK PREPARATIONS AND TBC NTD A3306 (STORAGE TANK VENT) VALVE 232 OPENING COMPLETE. LH2 STORAGE TANK VENT VALVE - OPEN ---------------------------------- AND LH2 FLARE STACK PREPS COMPLETE ---------------------------------- MPS HELIUM TANK PRESSURIZATION, T-0 ----------------------------------- GHE PURGE AND ORB/ET DISC CAVITY -------------------------------- PURGE ACTIVATION ---------------- 14-1492 NTD TBC PERFORM OPERATION SUPPORT SETUP SU72800 232 6 OF OMI G3251 - MPS HELIUM TANK TBC CLHY PRESSURIZATION TO FLIGHT PRESSURE, 136 T-0 UMBILICAL PURGE AND LH2 ORB/ET DISC CAVITY PURGE ACTIVATION. (2HR30MIN) 14-1493 CLHY TBC REQUEST CHGD AND CMPS SUPPORT ON 136 CHANNEL 166 FOR AFT GHE BACKGROUND TBC OTC CHECK DURING MPS HELIUM TANK 132 PRESSURIZATION TO FLIGHT PRESSURE, OTC CMPS T-0 PURGE AND ORB/ET DISC CAVITY CHGD PURGE ACTIVATION. 499 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 14-1494 CLHY TBC PERFORM FOLLOWING IN SUPPORT OF GHE 136 BACKGROUND CHECK DURING MPS HELIUM TBC OTC TANK PRESSURIZATION TO FLIGHT 132 PRESSURE, T-0 PURGE AND ORB/ET OTC CPVD DISC CAVITY PURGE ACTIVATION. 1. RECORD AFT PURGE (PC3) FLOW SETPOINT AND TOLERANCE. ______LBS/MIN BD 2. ADJUST AFT PURGE FLOWRATE TO 110 +/-5 LBS/MIN. 3. RECORD AFT PURGE FLOWRATE: ______LBS/MIN BD 4. RECORD PAYLOAD BAY PURGE (PC2) FLOWRATE: ______LBS/MIN BD 14-1495 CMPS OTC ATTENTION ON PAD___: 132 OTC NTD MPS HELIUM TANKS WILL BE PRESSURIZED 232 TO FLIGHT PRESSURE MOMENTARILY. NTD FLOW THROUGH THE LH2 TSM WILL BE PA AUDIBLE. 500 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0000 SHUTTLE COUNTDOWN ----------------- CONTROL SEQUENCE ---------------- (-11H THRU -6H) --------------- VERIFY READY TO RESUME COUNT ---------------------------- NOTE THIS IS COUNTDOWN RE-ENTRY POINT FOR 48 HOUR OR LONGER SCRUB/TURNAROUND OPERATIONS. THIS SEQUENCE MAY COMMENCE PRIOR TO SEQUENCE 14 COMPLETION AT NTD/OTC DISCRETION. OPERATIONS INVOLVING CRIT 1, 1R AND/OR 1S ITEMS ARE CONTAINED IN THE FOLLOWING SEQUENCE/STEPS. 15-0001 LPS JRPS VERIFY READY TO RESUME COUNT AT 127 JSDC T-11 HRS. | JCMC 15-0002 -11H00M NTD OTC VERIFY READY TO RESUME COUNT AT (HOLDING) 232 TBC T-11 HRS. IN ___ MINUTES. *FLT *MIL STM *SCC LPS PTC 501 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RESUME COUNT ------------ 15-0003 -11H00M NTD CGLS CDC WILL RESUME AT T-11 HOURS SU72533 COUNTING 232 SU72435 15-0004 NTD THE STS-_____ CDC IS AT T-11 PA HOURS AND COUNTING. 15-0005 VITT *PAD ORBITER PRE-OPERATION SETUP 18 - 132 MISSION UNIQUE CREW COMPARTMENT *PAD OTC CONFIGURATION COMPLETE. OPF HYPER EXHAUST FAN VERIFICATION ---------------------------------- 15-0006 NTD CTC VERIFY OPF 1, 2, AND 3 HYPER HVAA 232 EXHAUST FANS WILL NOT BE ACTIVATED CTC STM REMOTELY EXCEPT FOR AN EMERGENCY STM JBAC BEGINNING WITH T-11 (COUNTING) AND 111 CONTINUING THRU T-0 OF S0007. ET LOAD SAF/FAC/FIRE WALKDOWN (PART B) -------------------------------------- 15-0007 NTD TBC PERFORM INTEGRATED OPERATION SU72570 232 SUPPORT SETUP 5 - ET LOAD SAFETY/ SU72585 | TBC *PAD FACILITY/FIRE WALKDOWN (PART B MLP 136 ZERO LEVEL.) 502 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONFIGURE ELEVATORS ------------------- 15-0008 -11H00M STM VEEE CONFIGURE FSS AND RSS ELEVATORS CDPD NET PER OMI Q3018. SU72598 104 ESSENTIAL PERSONNEL ------------------- GSS --- SUPER/ENG 1 TECH 3 NOTE NEXT STEP MUST BE PERFORMED AT LAUNCH PAD TO MEET OMRS FILE SIX REQUIREMENTS. 15-0009 STM VEEE PERFORM THE FOLLOWING: NET 104 1. OPERATIONAL CHECK ON FSS ELEVATORS NO. 1 AND NO. 2 IN NORMAL SERVICE CONFIGURATION. 503 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0009 2. OPERATIONAL CHECK ON FSS CON'T ELEVATORS 1 AND 2 IN INDEPENDENT MODE TO THE 195 FT LEVEL AND SERVICE LEVEL. PAD A FSS 1 OMRSD GRVFEVRA1.005-1S TQW:____ NOT PERFORMED ______ PAD A FSS 2 OMRSD GRVFEVRA2.005-1S TQW:____ NOT PERFORMED ______ PAD B FSS 1 OMRSD GRXFEVRC0.005-1S TQW:____ NOT PERFORMED ______ PAD B FSS 2 OMRSD GRXFEVRD0.005-1S TQW:____ NOT PERFORMED ______ 3. UNLOCK ESCAPE HATCH IN FSS ELEVATORS 1 AND 2. TQW:____ 4. RETURN ELEVATORS TO NORMAL SERVICE. 504 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- HYDROGEN FIRE DETECTOR TEST --------------------------- VERIFICATION ------------ 15-0010 -11H00M CHGD OTC PERFORMING HYDROGEN FIRE SU72468 132 CGSS DETECTOR TEST VERIFICATION. CMPL FIRE DETECTORS WILL BE ACTIVATED OTC NTD MOMENTARILY EMONS WILL OCCUR 232 ON FIRE DETECTOR FUNCTION DESIGNATORS. NTD TBC TBC CLHY 136 CLOX 505 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP FOR EACH HYDROGEN FIRE DETECTOR SYSTEM: HWW14 = PADFD (LH2 HFDS) HWW15 = MLPFD (LH2 HFDS) HWW16 = EEFDS (EGR HFDS) 15-0011 CHGD CURSOR CNTL (SAQ06/HWW14/HWW15/HWW16) GROUP SELF TEST XMIT CURSOR KEY - PRESS CRT VERIFY "ALRM", "CONF", AND "SELF" INDICATION ON FOR EACH FIRE DETECTOR PRIMARY AND SECONDARY. CURSOR CNTL GROUP COMMAND OFF XMIT CURSOR KEY - PRESS CRT VERIFY "ALRM" AND "SELF" INDICATION OFF FOR EACH FIRE DETECTOR PRIMARY AND SECONDARY. REPORT ANY ANOMALIES. 15-0012 CHGD OTC HYDROGEN FIRE DETECTOR TEST 132 CGSS VERIFICATION COMPLETE. CMPL OTC NTD 232 NTD TBC TBC CLHY 136 CLOX 506 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- EEFDS CONFIDENCE INDICATION EMON -------------------------------- ACTIVATION ---------- 15-0013 CHGD CURSOR CNTL (SAW01/HWW10) EMON XMIT CURSOR KEY - PRESS AT LEAST TWICE TO SYCHRONIZE PSEUDO CRT VERIFY "EMON" INVERTED GREEN HGDS CONFIDENCE CHECKS ---------------------- 15-0014 OTC CHGD PERFORM REMOTE HGDS, BUHGDS AND SU72543 132 HUMS AUTO CALS AND CONFIDENCE SU72473 CHGD CTMS CHECKS. (3 HRS) 177 BUHGDS MONITOR ACTIVATION ------------------------- 15-0015 CHGD LCC ROOM 2P15A 9118 DISTRIBUTER (REAR) HGDS B/U SS MODEM SELECT PANEL RECORD FIRING RM, PAD AND FLOW NUMBER. FR__________ PAD__________ FLOW NO.__________ 507 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0015 1. IF SUPPORTING S0007 WITH CON'T FR1 TO PAD A, VERIFY SWITCH POSITIONS AS FOLLOWS: S1, CR1 - PAD A S2, CR3 - OFF S3, CR1 TX - ON NOT PERFORMED ______ SS1 2. IF SUPPORTING S0007 WITH FR1 TO PAD B, VERIFY SWITCH POSITIONS AS FOLLOWS: S1, CR1 - PAD B S2, CR3 - OFF S3, CR1 TX - ON NOT PERFORMED ______ SS2 3. IF SUPPORTING S0007 WITH FR3 TO PAD A, VERIFY SWITCH POSITIONS AS FOLLOWS: S1, CR1 - PAD A S2, CR3 - PAD A S3, CR1 TX - OFF NOT PERFORMED ______ SS3 4. IF SUPPORTING S0007 WITH FR3 TO PAD B, VERIFY SWITCH POSITIONS AS FOLLOWS: S1, CR1 - PAD B S1, CR3 - PAD B S1, CR1 TX - OFF NOT PERFORMED ______ SS4 508 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 STORAGE TANK VENT VALVE - OPEN ---------------------------------- AND LH2 FLARE STACK PREPS (SCRUB -------------------------------- TURNAROUND ---------- NOTE PERFORM NEXT TWO STEPS TO SUPPORT SCRUB/TURNAROUND OPERATIONS. PERFORM NEXT STEP A MINIMUM OF FOUR HOURS PRIOR TO PLANNED START OF LH2 LOADING. 15-0016 NTD TBC PERFORM OSSU 2 OF OMI G3255 - 232 A3306 (STORAGE TANK VENT) TBC CLHY VALVE OPENING. 136 NOT PERFORMED ______ 15-0017 CLHY TBC ATTENTION ON PAD ___: 136 TBC NTD LH2 VENTING TO FLARE STACKS 232 WILL OCCUR MOMENTARILY. NTD PA NOT PERFORMED ______ 509 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0018 -11H00M STM JPHO PLACE EMERGENCY CAMERA CONTROL SU72599 111 SYSTEM MODE SELECTOR IN MODE II POSITION AND VERIFY. SERVICE AIR COMPRESSORS ----------------------- 15-0019 STM JBPN PERFORM FOLLOWING: PNSA 111 SU72587 1. SERVICE AIR COMPRESSORS PER OMI M3022. (1HR) (APPENDIX B) 2. IF PORTABLE COMPRESSOR NOT | REQUIRED AS BACKUP, | RELOCATE PORTABLE AIR COMPRESSOR | TO NORTH BAY OF STORAGE BATTERY AND CONNECT TO SYSTEM. NOT PERFORMED ______ SS2 CONFIG ORBITER HYD FOR CRYO LOAD -------------------------------- NOTE HYDRAULIC CIRCULATION PUMPS MUST BE TURNED ON PRIOR TO START OF FUEL CELL ACTIVATION. PUMP LOADS ARE REQUIRED TO PROVIDE ADEQUATE LOADS FOR FUEL CELL PERFORMANCE CALIBRATION. PERFORM NEXT STEP IF FUEL CELLS ARE DEACTIVATED. 15-0020 OTC CEPD PERFORM LOCAL SENSE VOLTAGE SU72541 132 CONTROL DEACTIVATION PER OMI S9001VL2. RT OMI LOG NO.__________ NOT PERFORMED ______ 510 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0021 -11H00M OTC CHYD CONFIGURE HYDRAULIC SYSTEM FOR 132 COFC SHUTTLE CRYO LOADING/FUEL CELL CEPD ACTIVATION, PERFORM LDG FINAL ASP FILL AND ELEVON POSITIONING PER S0007VL4 (SEQ 46). (30 MIN) OMRS S00FC0.070-1R OMRS S00FC0.072-1R 15-0022 -10H40M CHYD OTC HYDRAULIC CIRC PUMPS RUNNING. SU72541 132 HYDRAULIC SYSTEM CONFIGURED FOR FUEL CELL ACTIVATION AND SHUTTLE CRYO LOADING. CONTINUING WITH LDG FINAL FILL AND ELEVON POSITIONING. OMRSD S00FC0.070-1R 15-0023 -10H30M CHYD OTC LDG FINAL FILL AND ELEVON 132 POSITIONING PER S0007VL4 (SEQ 46) COMPLETE. OMRSD S00FC0.072-1R WSB STEAM VENT HEATER ACTIVATION -------------------------------- 15-0024 -10H30M OTC CHYD PERFORM WSB STEAM VENT HEATER SU72534 132 ASP ACTIVATION PER S0007VL4 (SEQ 46 - HYDRAULIC SYSTEM). ECLSS O2 SAMPLE FOR CREW INGRESS COMPLETE ----------------------------------------- NOTE DO NOT PERFORM NEXT STEP UNLESS SEAT O2 SAMPLES WERE TAKEN. 15-0025 -10H30M CECL OTC ECLSS O2 SAMPLE FOR CREW INGRESS 132 COMPLETE (SEQ 45 S0007VL4). NOT PERFORMED ______ 511 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- STORAGE TANK VENT VALVE OPENING AND ----------------------------------- LH2 FLARE STACK PREPS (SCRUB ---------------------------- TURNAROUND) COMPLETE -------------------- NOTE PERFORM NEXT STEP TO SUPPORT SCRUB TURNAROUND OPERATIONS. 15-0026 -10H30M CLHY TBC G3255 OPERATION SUPPORT SETUP 2 - 136 A3306 (STORAGE TANK VENT) TBC NTD VALVE OPENING COMPLETE. 232 NOT PERFORMED ______ PIC RACK CB CONFIGURE/ ---------------------- 400 HZ PWR ACTIVATION --------------------- 15-0027 -10H30M OTC CEPD PERFORM PIC RACK CB SU72548 132 CMPS CONFIGURATION AND 400 HZ POWER ACTIVATION. PIC RACK CB CONFIGURATION ------------------------- 15-0028 -10H30M CEPD QPDS RACK 6814 (COMPT 7A) 151 22D170 (LH2 BURN PIC) CB - ON (CLOSED) RACK 6820 22D260 (LR PIC) CB - ON (CLOSED) RACK 6823 22D280 (LH2 BURN PIC) CB - ON (CLOSED) RACK 6815 22D330 (LR PIC) CB - ON (CLOSED) T:______ 512 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 400 HZ POWER ACTIVATION ----------------------- 15-0029 -10H30M CEPD QPDS C72-0818 (400 HZ GROUND POWER) 151 NOTE IN RACK 6800 OPERATIONS, CB NOMENCLATURE IS LISTED FOR REFERENCE ONLY. NOMENCLATURE IS NOT VISIBLE WHEN INDICATOR LITES OFF. RACK 6800 (COMPT 21A) 4 CB'S - ON (CLOSED) (1T110, 1T111, 1T112, 1T113 POWER) 4 CB'S - ON (CLOSED) (1T210, 1T211, 1T212, 1T213 POWER) PANEL P9 (COMPT 21A FAC AC) 1T100 CB4 - ON (CLOSED) 1T200 CB10 - ON (CLOSED) T:______ NOTE DO NOT PERFORM NEXT STEP FOR MLP 3. 15-0030 CEPD QPDS DISC SW P9 (COMPT 9A, LOCATED ON WALL) 151 1T100 SW C4 - ON (CLOSED) 1T200 SW C10 - ON (CLOSED) T:______ NOT PERFORMED ______ 513 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP FOR MLP 3. 15-0031 CEPD QPDS RACK 6824 (1T100) 151 MODE CONTROL LOCAL/REMOTE SW - REMOTE INPUT CB - ON STANDBY/OPERATE SW - OPERATE RACK 6825 (1T200) MODE CONTROL LOCAL/REMOTE SW - REMOTE INPUT CB - ON STANDBY/OPERATE SW - OPERATE T:______ NOT PERFORMED ______ 15-0032 CEPD CURSOR CNTL (VWC01) 1T100 ON/OFF XMIT CURSOR KEY - PRESS CRT (VWC01) VERIFY 1T100 ON/OFF IND ON 1T100 VOLTS PH A 109-118 VAC 1T100 VOLTS PH B 109-118 VAC 1T100 VOLTS PH C 109-118 VAC 514 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0033 CMPS CONSOLE KYBD SET_GASK0154E_ON XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS CEPD CRT (VWC01) 1T100 BUS IND ON 15-0034 CEPD CURSOR CNTL (VWC01) 1T200 ON/OFF XMIT CURSOR KEY - PRESS CRT (VWC01) VERIFY 1T200 ON/OFF IND ON 1T200 BUS IND OFF 1T200 VOLTS PH A 109-118 VAC 1T200 VOLTS PH B 109-118 VAC 1T200 VOLTS PH C 109-118 VAC 15-0035 CEPD OTC PIC RACK CB CONFIGURATION AND SU72548 132 400 HZ SYSTEMS ACTIVATION COMPLETE. 15-0036 OTC CMPL SSME WATER PANEL (C3) 132 VERIFY LH2 RECIRC PUMP PRIMARY LIGHT ON. CLEAR QPDS AND PPDS ------------------- 15-0037 -10H30M OTC CEPD CLEAR ALL PDS TECHNICIANS FROM SU72556 132 MLP AND PAD. SU72604 15-0038 CEPD OTC PDS TECHS CLEARING MLP AND 132 PAD. OTC NTD 232 515 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ENABLE CONDITION RED STROBE LIGHT --------------------------------- 15-0039 -10H30M NTD STM PLACE CONDITION RED STROBE COMM 232 LIGHT SWITCH IN PTCR ROOM 205 IN STM GYCC ENABLE (ON) POSITION. ATTACH 111 INTEGRITY CONTROL STICKER TO GYCC JYCJ SWITCH. 117 PTP PSOQ 15-0040 JYCJ GYCC CONDITION RED STROBE LIGHT SWITCH COMM 117 IN PTCR ROOM 205 HAS BEEN PLACED GYCC STM IN ENABLE (ON) POSITION AND 111 INTEGRITY CONTROL STICKER HAS STM NTD BEEN ATTACHED TO SWITCH. 232 ESSENTIAL PERSONNEL ------------------- UCOM UQA ---- --- TECH 2 QUAL 1 TQV:____ ECS PREPS FOR AIR/GN2 CHANGEOVER -------------------------------- COMPLETE (HAND VALVE CLOSED) ---------------------------- 15-0041 -10H30M CPVD OTC ECS INITIAL PREPS FOR AIR/GN2 SU72544 132 CHANGEOVER COMPLETE (HAND VALVES OTC NTD CLOSED) (V1122). 232 FINAL PREPS FOR AIR/GN2 CHANGEOVER ---------------------------------- 15-0042 OTC CPVD PERFORM OMI V1122 "PREPS FOR | 132 AIR/GN2 CHANGEOVER,OPTION B - FINAL PREPS" SEQUENCE (HAND SU72546 | VALVES CLOSED). (30 MIN) RT OMI LOG NO.__________ 516 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE XENON LIGHTS --------------------- WARNING WHEN XENON LIGHTS ARE OPERATING, PERSONNEL MUST AVOID LOOKING DIRECTLY INTO LIGHTS AS EYE DAMAGE MAY RESULT. NOTE DO NOT PERFORM NEXT TWO STEPS IF TANKING AND LAUNCH WILL OCCUR DURING DAYLIGHT. 15-0043 -10H30M STM NTD ATTENTION ON PAD ___: SU72519 232 SU72509 NTD XENON LIGHTS WILL BE TURNED ON. PA AVOID LOOKING INTO LIGHTS. EYE DAMAGE MAY RESULT. NOT PERFORMED ______ NOTE XENON FLOODLIGHTS WILL NOT BE TURNED ON DURING THE RSS MOVE FROM MATE POSITION UNTIL TRUCK 1 HAS BEEN SECURED IN THE PARK POSITION. 15-0044 -10H30M STM JSTC TURN ON XENON LIGHTS FOR LAUNCH SU72516 | 111 BORESITE IF REQUIRED. TOP OFF SU72509 GEN FUEL TANKS. (30 MIN) ELEC | ESSENTIAL PERSONNEL ------------------- SGS BICO NASA | --- ---- ---- TECHS 7 SUPVR. 1 ENGR 1 NOT PERFORMED ______ 517 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF JYVO DETERMINES CAMERA PURGE IS REQUIRED (JYVO CH 138). 15-0045 STM JBPN OPEN SUPPLY VALVES AND ADJUST PNSA 111 REGULATORS TO SUPPLY CAMERAS SU72600 70 AND 71 (PAD A) OR 170 AND 171 (PAD B) WITH 30 TO 50 PSI OF PURGE. RECORD SUPPLY PRESSURE 70/170______ PSI; 71/171______ PSI. NOT PERFORMED ______ PAD CLOSEOUT VALVE POSITIONING ------------------------------ NOTE NEXT STEP REQUIRES ACCESS TO PAD A, PAD B AND VAB HIGH PRESSURE STORAGE BATTERIES BY PNEUMATICS, QUALITY AND NASA PERSONNEL. 15-0046 STM JBPN PERFORM PAD CLOSEOUT VALVE PNSA 111 POSITIONING PER OMI M3123. SU72662 ESSENTIAL PERSONNEL ------------------- GSS NASA --- ---- SUPR/ENGR 1 1 QUALITY 1 PNEU TECH 3 518 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF SUPPORTING SCRUB TURNAROUND AND HELIUM PURGES ARE REQUIRED TO BE ACTIVATED. 15-0047 TBC CLHY PERFORM OMI G3255 OPERATION SUPPORT 136 SETUP 11 - ACTIVATION OF HELIUM PURGES AFTER TEMPORARY SECURING. NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF SUPPORTING SCRUB TURNAROUND AND HELIUM PURGES WERE INITIATED. 15-0048 CLHY TBC G3255 OPERATION SUPPORT SETUP 11 - 136 ACTIVATION OF HELIUM PURGES AFTER TBC NTD TEMPORARY SECURING COMPLETE. 232 NOT PERFORMED ______ CLEAR FOR STANDBY GN2 MODE -------------------------- 15-0049 -10H15M NTD *SCC REQUEST SFOC SAFETY CLEAR ALL STSA | 232 STM PERSONNEL FROM MLP A AND B *SCC *PSE LEVELS FOR ECS AIR TO "STANDBY NET GN2 MODE" (HAND VALVE OPEN) 105 OPERATIONS. GSS TECHS TO STM QBSE ACCOMPANY SAFETY TO D0G ALL NET MLP DOORS (EXCEPT DOOR 33A) 104 AFTER INSPECTION COMPLETE. 15-0050 NTD *SCC PERFORM FOLLOWING: 232 STM *SCC *PSE 1. REQUEST SFOC SAFETY CLEAR HVAA NET ALL PERSONNEL FROM PTCR. 105 STM JBAC 2. GSS TECHS TO ACCOMPANY HVAA 111 SAFETY TO CLOSE UPPER AND LOWER PTCR BLAST DOORS AND INSTALL GSS SIGNS PER OMI M3034. 519 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0050 3. GSS TECHS TO STAND BY FOR HVAA CON'T PTCR/ECS ROOM PRESSURIZATION COMMAND STEP. ESSENTIAL PERSONNEL TO ECS ROOM ------------------------------- WARNING EACH PERSON ON STATION IN ECS ROOM DURING HIGH FLOW OF GN2 WILL HAVE AN ELSA IN HIS IMMEDIATE AREA. REQUEST SFOC SAFETY CLEAR NONESSENTIAL PERSONNEL FROM ECS ROOM AND STAND BY FOR GN2 HAND VALVE OPERATIONS. 15-0051 -10H15M NTD *SCC REQUEST ESSENTIAL PERSONNEL 232 OTC REPORT TO PAD ECS ROOM FOR OTC CPVD STANDBY GN2 MODE (HAND VALVE 132 OPEN). VERIFY ECS PERSONNEL *SCC *PSE HAVE 10 MINUTE ELSAS. (45 MIN) NET 105 ESSENTIAL PERSONNEL ------------------- SFOC NASA GSS ---- ---- --- SYST ENG 1 1 1 SYST QC 1 SYST TECH 4 4 SAFETY 1 1 SUPV 1 520 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE SAFETY WARNING SIGNS MAY NOT REQUIRE POSTING IF PAD CLEARING FOR LAUNCH IS IN PROGRESS; WITH SFOC SAFETY CONCURRENCE. 15-0052 -10H15M NTD *SCC VERIFY SAFETY SIGNS INSTALLED AT: 232 *SCC *PSE 1. PTCR AND ECS ROOM DOORS (THREE). NET 105 2. PTCR SOUTH TUNNEL ENTRANCE. 3. MLP "B" LEVEL AIRLOCK. (SIGN SHALL BE REMOVED UPON FINAL CLEARING FOR LAUNCH). 4. ECS ROOM SOUTH OUTSIDE ENTRANCE. (SAFETY WARNING SIGN SHALL BE POSTED UPON FINAL ECS ROOM CLEARING). 5. ECS ROOM TO PTCR RM 105 ENTRANCE (SIGN POSTED AFTER CLEARING THRU PTCR TO ECS ROOM). NOT PERFORMED ______ 15-0053 NTD ATTENTION ON PAD ___: PA ALL PERSONNEL CLEAR MLP INTERIOR AND PTCR FOR ECS AIR TO "STANDBY GN2 MODE (HAND VALVES OPEN)". ALL NONESSENTIAL PERSONNEL CLEAR THE ECS ROOM. RSS POST ROLLBACK SECURING COMPLETE ----------------------------------- 15-0054 QBSE STM RSS POST ROLLBACK SECURING STSA | NET COMPLETE. 104 521 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0055 *PAD OTC RSS PLATFORMS HAVE BEEN SECURED 132 FOR LAUNCH. MOVE POST OPERATION OTC NTD PER A2203.002 COMPLETE. 232 ELEVATOR SECURING STATUS ------------------------ 15-0056 -10H00M VEEE STM HYDRAULIC ELEVATOR NO. 2 HAS CDPD NET BEEN SECURED PER OMI Q3018. SU72490 104 15-0057 -10H00M VEEE STM FSS AND RSS ELEVATORS CDPD NET CONFIGURATION PER OMI Q3018 SU72598 104 COMPLETE. 15-0058 VEEE STM FUNCTIONAL CHECK OF PAD___ CDPD NET ELEVATORS COMPLETE PER Q3018. 104 T:______ 15-0059 JBPN STM AIR COMPRESSORS SERVICED. METAL PNSA 111 RETAINING BARS SECURED ON SU72587 BUILDING DOORS. 15-0060 TBC CMQC VERIFY SRB PRE-OPERATION SETUP SU72575 136 5 - ER CIRCUIT PATCHING COMPLETE. | AIR PACKS TO PAD GATE | --------------------- | | 15-0061 -10H00M STM JSTC POSITION 16 30 MINUTE AIR PACKS LS | 111 WITH VEHICLE AND TECHNICIAN AT | JSTC *SCB PAD ___ GATE FROM T-9H30M TO | NET T-6H30M. RETURN TO COMPLEX J. | 104 (30 MIN) | | 522 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING REINSTALLATION OF SRB ESP OR ACCESS TO SRB AFT SKIRT AREA REQUIRES VERIFICATION THAT AFT SKIRT GN2 PURGE IS TERMINATED. 15-0062 TBC CBHY ACTIVATE SRB GN2 AFT SKIRT GN2 SU72577 136 PURGE PER SRB OPERATION SUPPORT SU72603 | SETUP 5 - SRB AFT SKIRT GN2 PURGE ACTIVATION AS TEMPERATURES REQUIRE. NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF SCRUB TURNAROUND PERFORMED AND PAD REMAINED CONTROLLED. 15-0063 STM QBSE PICK UP ANY LOOSE ITEMS/DEBRIS STSA | NET FROM SRB HAUNCH AREAS. 104 T:______ NOT PERFORMED ______ FUEL CELL PULSE PURGE COMPLETE ------------------------------ NOTE DO NOT PERFORM NEXT STEP IF FUEL CELLS ARE POWERED UP AND RUNNING (SCRUB/RECYCLE). 15-0064 -10H00M CFCP OTC FUEL CELL PULSE PURGE COMPLETE. SU72540 132 (V1040.002) OTC NTD 232 NOT PERFORMED ______ 523 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM FUEL CELL ACTIVATION IF FUEL CELLS ARE POWERED UP AND RUNNING (SCRUB/RECYCLE). FUEL CELL ACTIVATION -------------------- NOT PERFORMED ______ NOTE DO NOT ACTIVATE FUEL CELLS UNTIL HYDRAULIC CIRCULATION PUMPS ARE VERIFIED RUNNING. PUMP LOADS ARE REQUIRED TO PROVIDE ADEQUATE LOADS FOR FUEL CELL PERFORMANCE CALIBRATION. 15-0065 OTC CECL VERIFY AIRLOCK VACUUM VENT DUCT 132 GN2 INERTING ESTABLISHED FOR 30 MINUTES MINIMUM AND READY TO SUPPORT FUEL CELL ACTIVATION. 15-0066 -10H00M NTD OTC PROCEED WITH FUEL CELL 232 ACTIVATION. (2H30M) REPORT SU72619 COMPLETION FOR EACH FUEL CELL. FC1______GMT FC2______GMT FC3______GMT 524 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0067 -10H00M OTC CEPD SUPPORT ORBITER FUEL CELL ACTIVATION 132 AND FUEL CELL APPLICATION TO MAIN BUSSES PER OMI S9001VL2 ON OIS CH 151. RT OMI LOG NO.__________ NOTE FUEL CELLS MUST BE ACTIVATED WITHIN 3 HOURS ELAPSED TIME FROM COMPLETION OF FC REACTANT PURGE. CECL MONITOR HEAT LOAD IMPACT OF NEXT STEP. 15-0068 -10H00M OTC CFCP PERFORM ORBITER FUEL CELL 132 ACTIVATION PER OMI V1040.002 ON OIS CH 153. (2HR) REPORT READY FOR LOAD STATUS TO CEPD. 15-0069 OTC ASP FUEL CELL STACK TEMP C & W ALARMS 132 CISL MAY OCCUR DURING FUEL CELL CTPE START. FUEL CELL ACTIVATION COMPLETE ----------------------------- 525 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRGA POWER REDUNDANCY VERIFICATION ---------------------------------- 15-0070 -10H00M OTC CEPD PERFORM SRGA POWER REDUNDANCY SU72567 132 CMPS TEST ON OIS CHANNEL 151. REPORT COMPLETION. 15-0071 CEPD OTC REQUEST CONCURRENCE TO REMOVE 132 PREFLIGHT SOURCE ESS BUS 3AB IN SUPPORT OF SRGA POWER REDUNDANCY TEST. 15-0072 CEPD CMPS VERIFY MPS LO2 FEED D/V OP RPC 76X4196E1 151 B ON. 15-0073 CEPD CURSOR CNTL (VWC17) ESSENTIAL BUS SOURCE 3AB PREFLT - OFF XMIT CURSOR KEY - PRESS CRT (VWC17) ESS BUS SOURCE 3AB PREFLT IND OFF 15-0074 CEPD CMPS VERIFY MPS LO2 FEED D/V OP RPC 76X4196E1 B ON. OMRSD S00FA0.630 15-0075 CEPD CURSOR CNTL (VWC17) ESSENTIAL BUS SOURCE 3AB PREFLT - ON XMIT CURSOR KEY - PRESS CRT (VWC17) ESS BUS SOURCE 3AB PREFLT IND ON 15-0076 CEPD OTC SRGA REDUNDANCY TEST COMPLETE 132 526 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PTCR CLOSEOUT COMPLETE ---------------------- 15-0077 -10H00M JBAC STM ALL PTCR CLOSEOUT STEPS COMPLETE. HVAA 111 SU72499 STM NTD 232 NOTE HVAC ENGR WILL DETERMINE IF NEXT STEP REQUIRED. 15-0078 STM JBAC CONFIGURE PAD-___ PTCR HVAC HVAA 111 SYSTEM WATER CHILLER(S) WITH WC-1 AND/OR WC-2 ON LINE AND OPERATING DEPENDING ON SYSTEM LOAD, WITH WC-3 IN STANDBY, PER HVAC SUPERVISION/ ENGINEERING DIRECTION, AND PER OMI M3006 PAD A/OMI M3023 PAD B. REPORT FINAL CONFIGURATION. NOT PERFORMED ______ NOTE HVAC ENGINEER WILL DETERMINE IF CAPACITY AND INTEGRITY OF FACILITY CHILLED WATER SYSTEM WARRANTS PERFORMANCE OF NEXT STEP. 15-0079 STM JBAC CLOSE RSS MANUAL ISOLATION HVAA 111 VALVES. SECURE PUMP P-8 AND/OR P-9. T:______ NOT PERFORMED ______ ET LOAD SAF/FAC/FIRE WALKDOWN ----------------------------- (PART B) COMPLETE ----------------- 15-0080 *PAD TBC INTEGRATED OPERATION SUPPORT SU72570 136 SETUP 5 - ET LOAD SAFETY/FACILITY/ TBC NTD FIRE WALKDOWN (PART B) COMPLETE. 232 NTD *SCC 527 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAD STRUCTURES LAUNCH CLOSEOUT ------------------------------ COMPLETE -------- 15-0081 QBSE STM PAD STRUCTURES LAUNCH CLOSEOUT STSA | NET COMPLETE PER M3134/M3083. SU72515 104 MPS HELIUM TANK PRESSURIZATION, T-0 ----------------------------------- GHE PURGE AND ORB/ET DISC CAVITY -------------------------------- PURGE ACTIVATION COMPLETE ------------------------- NOTE DO NOT PERFORM NEXT TWO STEPS IF PERFORMING A SCRUB TURNAROUND. 15-0082 CLHY TBC GHE BACKGROUND CHECK COMPLETE. AFT 136 PURGE HIGH FLOW NO LONGER REQUIRED. TBC OTC REQUEST PVD ADJUST AFT PURGE FLOW 132 SETPOINT TO PREVIOUS VALUE. OTC CPVD NOT PERFORMED ______ 15-0083 CLHY TBC G3251 OPERATION SUPPORT SETUP 6 SU72800 136 MPS HELIUM TANK PRESSURIZATION TO TBC NTD FLIGHT PRESSURE, T-0 UMBILICAL 232 PURGE, AND LH2 ORB/ET DISC CAVITY PURGE ACTIVATION COMPLETE. OMRSD S00FA0.225 OMRSD S00FF0.070-1 OMRSD S00FE0.020-1 NOT PERFORMED ______ 528 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FCE TIME CRITICAL STOWAGE COMPLETE ---------------------------------- 15-0084 -09H30M OOCS OTC DOSIMETER AND FCE TIME CRITICAL 132 ITEMS INSTALLATION PER V5097.003 COMPLETE OR IN CASE OF SCRUB TURNAROUND INSTALLATION COMPLETE PER FCS TPS. NOTE SEAT SWITCHES WILL BE ACTIVATED AND VENTILATION FAN POWER WILL BE CYCLED IN NEXT FOUR STEPS. NOTIFY CEPD. CDR/PLT SEAT ADJUST ------------------- 15-0085 -09H30M ASP OTC PROCEEDING WITH POSITIONING OF SU72560 132 CDR AND PLT SEATS. 15-0086 ASP OTC CDR/PLT SEAT ADJUST COMPLETE. 132 15-0087 CFCP OTC A FUEL CELL HAS BEEN STARTED, 132 READY FOR TERMINATION OF AIRLOCK OTC CECL VACUUM VENT DUCT GN2. 529 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 30 MIN AIR PACKS AT PAD GATE ---------------------------- 15-0088 *SCB JSTC SIXTEEN 30 MIN AIR PACKS LS NET POSITIONED WITH VEHICLE AND SU72591 104 TECHNICIAN AT PAD ___ GATE. 15-0089 *SCB JSTC FOLLOWING IS COMPLETE: LS JSTC STM SU72512 111 1. ELSA BOXES REMOVED FROM FSS, SU72517 | EXCEPT FOR BOX ADJACENT ELEVATORS ON 195 FT LEVEL. 2. ELSA BOX REMOVED FROM EAST PAD APRON. 3. LIFE SUPPORT EQUIPMENT IN FSS WHITE ROOM VERIFIED. PAV DELIVERY TO SLIDEWIRE BUNKER -------------------------------- 15-0090 STM JSTC DELIVER PAV'S NOT REQUIRED BY LS 111 FLIGHT CREW TO SLIDEWIRE BUNKER SU72592 JSTC *SCB (PAV DURATION 14H30M FROM TIME OF DELIVERY). MOVE TAIR TRAILER (CONTINGENCY) ------------------------------- NOTE PERFORM NEXT STEP IF TAIR TRAILER AT PAD. 15-0091 -09H30M OTC NTD PERFORM SUPPORT OPERATION SU72596 232 SUPPORT SETUP 1 TO MOVE TAIR NTD STM TRAILER NO. ______ FROM ______ TO ______ (LAUNCH LOCATION) (1 HR). NOT PERFORMED ______ 530 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0092 CECL OTC AIRLOCK VACUUM VENT DUCT GN2 132 INERTING/DISCONNECT COMPLETE PER SU72449 OTC NTD ORBITER OPERATION SUPPORT 232 SETUP 5. GOX VENT SYSTEM FINAL ACTIVATION -------------------------------- COMPLETE -------- 15-0093 CMEC TBC GOX VENT SYSTEM FINAL ACTIVATION SU72571 136 FOR LOX LOADING PER G2158 TBC NTD COMPLETE. 232 531 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAD CLEARING STATUS (MLP/PTCR/ECS ROOM) --------------------------------------- 15-0094 -09H30M *PSE *SCC ALL PERSONNEL ARE CLEAR FROM MLP SU72556 NET INTERIOR AND PTCR. ALL NONESSENTIAL 105 PERSONNEL HAVE CLEARED ECS ROOM. *SCC NTD 232 NTD OTC NOTE SAFETY WARNING SIGNS MAY NOT REQUIRE POSTING IF PAD CLEARING FOR LAUNCH IS IN PROGRESS; WITH SFOC SAFETY CONCURRENCE. 15-0095 *PSE *SCC SAFETY SIGNS ARE INSTALLED AT: NET 105 1. PTCR AND ECS ROOM DOORS (3). *SCC NTD 232 2. PTCR SOUTH TUNNEL ENTRANCE. 3. MLP "B" LEVEL AIRLOCK. (SIGN SHALL BE REMOVED UPON FINAL CLEARING FOR LAUNCH). 4. ECS ROOM SOUTH OUTSIDE ENTRANCE (SAFETY WARNING SIGN SHALL BE POSTED UPON FINAL ECS ROOM CLEARING). NOT PERFORMED ______ 15-0096 OTC NTD ALL ORBITER COMPARTMENTS HAVE 232 BEEN CLOSED OUT EXCEPT FOR NTD *SCC CREW COMPARTMENT. FINAL PREPS FOR AIR/GN2 ----------------------- CHANGEOVER COMPLETE ------------------- 15-0097 CPVD OTC FINAL PREPS FOR AIR/GN2 SU72546 132 CHANGEOVER (HAND VALVES CLOSED) OTC NTD COMPLETE. 232 532 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0098 NTD *SCC VERIFY CONCURRENCE TO PROCEED 232 WITH ECS SYSTEM "STANDBY GN2 *SCC *PSE MODE (OPTION A) (HAND VALVE OPEN)" NET OPERATIONS (V1122). 105 15-0099 *PSE *SCC SAFETY CONCURS TO PROCEED WITH NET "STANDBY GN2 MODE (OPTION A) (HAND 105 VALVE OPEN)" OPERATIONS. ALL *SCC NTD NONESSENTIAL PERSONNEL CLEAR 232 AND 10 MINUTE ELSAS AVAILABLE. SAFETY WARNING SIGNS HAVE BEEN INSTALLED, ECS ROOM PERSONNEL HAVE REQUIRED EAR PROTECTION AND CONTINUOUS O2 MONITORING IN EFFECT. STANDBY GN2 MODE (HAND VALVE OPEN) ---------------------------------- 15-0100 OTC CPVD BRIEF PERSONNEL ON HAZARDS THAT 132 WILL BE PRESENT AND APPLICABLE SEQUENCES OF APPENDIX Z. WARNING HAZARDOUS OPERATION - AIR TO GN2 STANDBY MODE FOLLOWS. HAZ DUE TO POSSIBLE PRESENCE OF GN2. 15-0101 -09H30M NTD OTC PROCEED WITH ECS "STANDBY GN2 PNU 232 STM MODE (OPTION A) (HAND VALVE SU72549 STM JSTC OPEN)" OPERATION. (V1122) 111 JSTC GSPN 114 15-0102 OTC CPVD PERFORM OMI V1122 SEQUENCE "AIR 132 TO GN2 STANDBY MODE/AIR TO GN2 CHANGEOVER OPTION A - AIR TO GN2 STANDBY MODE". COORDINATE WITH GSPN ON OIS CH 172. RT OMI LOG NO.__________ 533 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAD SURFACE AND ABOVE CLEAR OF ------------------------------ NONESSENTIAL PERSONNEL ---------------------- NOTE PERFORM NEXT THREE STEPS 45 MINUTES PRIOR TO AIR TO GN2 CHANGEOVER. 15-0103 NTD OTC VERIFY NONESSENTIAL PERSONNEL CLEAR 232 TBC OF PAD SURFACE AND ABOVE FOR AIR TO STM GN2 CHANGEOVER. ANY EXCEPTION MUST LPS BE APPROVED BY NTD AND *SCC. PTC ESSENTIAL PERSONNEL ------------------- - NVM FINAL WALKDOWN PARTICIPANTS - CREW MODULE/WHITE ROOM PERSONNEL 15-0104 NTD *SCC CLEAR PAD SURFACE AND ABOVE OF ALL 232 NONESSENTIAL PERSONNEL FOR AIR TO GN2 *SCC *PSE CHANGEOVER. ESTABLISH BARRIER ACROSS NET "B" ROAD AND POST HAZARD WARNING SIGN. 105 15-0105 NTD ATTENTION ON PAD___: PA ALL NONESSENTIAL PERSONNEL CLEAR PAD___ PAD SURFACE AND ABOVE FOR AIR TO GN2 CHANGEOVER PREPARTIONS. 15-0106 *SCC NTD RELEASE OICS FROM STATIONS AT WHITE | 232 ROOM, 195 FT LEVEL, AND BASE OF FSS. 15-0107 JSTC GSPN MAINTAIN GHE AND GN2 SYSTEM PNU 114 PRESSURES AT MAXIMUM LEVELS FOR REMAINDER OF COUNTDOWN. NOTIFY CCF-39 GN2 PRODUCTION PLANT TO RAISE MINIMUM PIPELINE PRESSURE TO 6000 PSIG. 534 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM TRANSFER CONTROL OF ORBITER FIREX SYSTEM - CCC TO FR FOR INITIAL CONTROL TRANSFER AND TO SUPPORT ANY TURNAROUND THAT HAS TRANSFERRED ORBITER FIREX FROM FIRING ROOM TO CCC. TRANSFER CONTROL OF ORBITER FIREX --------------------------------- SYSTEM - CCC TO FR ------------------ NOT PERFORMED ______ 15-0108 -09H15M STM JBFX VERIFY FSS AND MLP FIREX SYSTEM WSSA 111 HAS BEEN CONFIGURED TO SUPPORT. SU72589 15-0109 -09H15M STM NTD CCC READY TO TRANSFER CONTROL OF 232 ORBITER FIREX TO FR. REQUEST NTD OTC CMPL CONTACT JBFX ON CH 123. OTC CMPL 132 15-0110 STM JBFX TRANSFER CONTROL OF ORBITER WSSA 111 FIREX WATER SYSTEM TO FR CONTROL. (15 MIN) 15-0111 JBFX CMPL VERIFY READY FOR CONTROL WSSA 123 TRANSFER. 15-0112 CMPL CRT (SAE02) SSME WATER SPRAY SYSTEM (PAGE A) VERIFY NO ARM/OPEN COMMANDS APPLIED 15-0113 CMPL JBFX READY FOR TRANSFER OF ORBITER WSSA 123 FIREX SYS TO FIRING ROOM. 15-0114 JBFX CMPL STAND BY FOR CONTROL TRANSFER. WSSA 123 535 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE CCC WILL TRANSFER CONTROL OF ORBITER FIREX SYSTEMS TO FIRING ROOM BY PERFORMING NEXT STEP. 15-0115 JBFX CRT (P2A OR P2B) WSSA VERIFY INDICATOR STATE --------- ----- FX CCC ENABLE ON(GREEN) FX CCC-ON/FR-OFF ON(GREEN) FX FR ENABLE OFF(YELLOW) FX FR-ON/CCC-OFF OFF(YELLOW) CONSOLE KYBD CURSOR TO "C" OF FX FR ON/CCC - OFF" XMIT CURSOR KEY - PRESS PFP "PAD A" (NO. 1) OR "PAD B" KEY (NO. 2) - PRESS "TURN ON" KEY (NO. 1) - PRESS CONSOLE KYBD EXEC CMD KEY - PRESS CRT (P2A) OR (P2B) VERIFY INDICATOR STATE --------- ----- FX CCC ENABLE OFF(YELLOW) FX CCC-ON/FR-OFF OFF(YELLOW) FX FR ENABLE ON(GREEN) FX FR-ON/CCC-OFF ON(GREEN) 536 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0116 JBFX CMPL ORBITER FIREX SYS TRANSFERRED WSSA 123 TO FR CONTROL. PROCEED WITH JBFX STM FR VALIDATION. 111 15-0117 CMPL SSME PAD WATER SAFING PANEL VERIFY "WATER BUS ON" LITE-ON. 15-0118 CMPL OTC CONTROL OF ORBITER FIREX SYSTEM 132 NOW AT MPS CONSOLE. TRANSFER OF OTC NTD ORBITER FIREX SYS CCC TO FR 232 COMPLETE. TRANSFER OF ORBITER FIREX SYSTEM - ---------------------------------- CCC TO FR COMPLETE ------------------ NOTE PERFORM TRANSFER CONTROL OF SOUND SUPPRESSION SYSTEM - CCC TO FR FOR INITIAL CONTROL TRANSFER AND TO SUPPORT ANY SCRUB TURNAROUND THAT HAS TRANSFERRED CONTROL OF SOUND SUPPRESSION SYSTEM FROM FIRING ROOM TO CCC. TRANSFER CONTROL OF SOUND SUPPRESSION ------------------------------------- SYSTEM -CCC TO FR ----------------- NOT PERFORMED ______ 15-0119 -09H15M STM JBWC VERIFY SOUND SUPPRESSION WATER WSSA 111 SYSTEM HAS BEEN CONFIGURED TO SUPPORT. 15-0120 -09H15M STM NTD CCC READY TO TRANSFER CONTROL OF 232 SS WATER TO FR. REQUEST CGSS NTD OTC CONTACT JBWC ON CH 123. OTC CGSS 132 15-0121 STM JBWC TRANSFER CONTROL OF SS WATER WSSA 111 SYSTEM TO FR CONTROL. 537 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0122 JBWC CGSS VERIFY READY FOR CONTROL WSSA 123 TRANSFER. 15-0123 CGSS CURSOR CNTL (VAJ14) VAJ12 - ON VERIFY 1. VERIFY TANK LVL GREATER THAN OR EQUAL TO 258.2 FT 2. GN2 PRESS PT 1 GREATER THAN 1200 PSI, LESS THAN 1700 PSI PT 2 GREATER THAN 1200 PSI, LESS THAN 1700 PSI CMD MEAS --- ---- 3. CCC LOCKOUT ON - - X - 4. CCC ENABLE CMD OFF X - 5. CCC ENABLED IND ON - - X - 6. FR ENABLED IND OFF - - - 7. SS SOL PWR OFF X X BUS ON CMD 8. SS SOL PWR OFF - - BUS OFF CMD 9. SS FR CMD OFF BUS PWR ON CMD 10. PRE L/O VENT OFF - - VLV OPEN CMD 11. PRE L/O VLVS OFF - OPEN CMD IND 12. PRE L/O VLVS ON - - X - CLOSE CMD IND 13. POST L/O VENT OFF - - VLV OPEN CMD 538 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0123 14. POST L/O VLVS OFF - - - CON'T OPEN CMD IND 15. POST L/O VLVS ON - - X - OPEN CMD IND 16. VV5,6,7,8,9,10 GRAPHIC BLOCKS - SOLID GREEN 17. PREV25,26,27 AND POST V28,29,30 BLOCKS - SOLID GREEN 18. STATUS ARROW - CYCLING 15-0124 CGSS JBWC READY FOR TRANSFER OF SOUND WSSA SUPPRESSION CONTROL TO FIRING ROOM. 15-0125 JBWC CGSS STAND BY FOR CONTROL TRANSFER. WSSA 123 NOTE CCC WILL TRANSFER CONTROL OF SOUND SUPPRESSION SYSTEM TO FIRING ROOM BY PERFORMING NEXT STEP. 15-0126 JBWC CRT (P2A OR P2B) WSSA VERIFY INDICATOR STATE --------- ----- SS CCC ENABLE ON(GREEN) SS CCC-ON/FR-OFF ON(GREEN) SS FR ENABLE OFF(YELLOW) SS FR-ON/CCC-OFF OFF(YELLOW) CONSOLE KYBD CURSOR TO "C" OF "SS FR ON/CCC - OFF" XMIT CURSOR KEY - PRESS 539 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0126 PFP CON'T "PAD A" (NO. 1) OR "PAD B" KEY (NO. 2) - PRESS "TURN ON" KEY (NO. 1) - PRESS CONSOLE KYBD EXEC CMD KEY - PRESS CRT (P2A) OR (P2B) VERIFY INDICATOR STATE --------- ----- SS CCC ENABLE OFF(YELLOW) SS CCC-ON/FR-OFF OFF(YELLOW) SS FR ENABLE ON(GREEN) SS FR-ON/CCC-OFF ON(GREEN) 15-0127 JBWC CGSS SOUND SUPPRESSION SYS TRANSFERED WSSA 123 TO FR CONTROL. PROCEED WITH FR JBWC STM VERIFICATION. 111 15-0128 -09H15M CGSS VERIFY SS CONTROL TRANSFER COMPLETE BY OBSERVING VAJ14 SKELETON STATUS AS FOLLOWS: CONTROL CCC OFF FR ON 15-0129 CGSS OTC TRANSFER OF SS SYS CCC TO FR SU72589 132 COMPLETE. OTC NTD 232 TRANSFER CONTROL OF SOUND SUPPRESSION ------------------------------------- SYSTEM - CCC TO FR COMPLETE --------------------------- 540 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- EMERGENCY EGRESS FLAME DETECTION SYSTEM --------------------------------------- INITIATION ---------- 15-0130 CGSS CURSOR CNTL (VAJ14) SU72550 VAJ15 - ON 15-0131 CGSS CRT (VAJ15) VERIFY ALL TEMPERATURE DETECTORS LESS THAN 120 DEGREES F. ALL FLAME DETECTORS OFF. 15-0132 CGSS OTC EMERGENCY EGRESS FLAME DETECTION 132 SYSTEM MONITORING ACTIVATED. OTC NTD 232 15-0133 OTC CGSS MONITOR SOUND SUPPRESSION AND 132 EMERGENCY EGRESS FLAME DETECTION SYSTEM PER ORBITER OPERATION SUPPORT SETUP 18 - SOUND SUPPRESSION/EMERGENCY EGRESS FLAME DETECTION MONITOR. PCR PRESSURE VERIFICATION ------------------------- 15-0134 -09H15M OTC CPVD VERIFY POSITIVE AIR PRESSURE IN PCR. 132 541 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VENT DOOR RECONFIGURATION ------------------------- NOTE PERFORM NEXT THREE STEPS IF VENT DOORS ARE IN ADVERSE WEATHER PURGE CONFIGURATION. 15-0135 OTC CPVD POSITION ORBITER VENT DOORS TO SU72559 132 NORMAL PURGE CONFIGURATION. NOT PERFORMED ______ 15-0136 CPVD CURSOR CNTL (VAM31A/VAM09A) COMMAND VENT DOORS TO NORMAL PURGE CONFIGURATION. NOT PERFORMED ______ 15-0137 CPVD OTC ORBITER VENT DOORS IN NORMAL 132 PURGE CONFIGURATION. NOT PERFORMED ______ 542 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CREW COMPARTMENT CHECKS ----------------------- 15-0138 -09H15M NTD OTC VERIFY CONTINUOUS MONITORING 232 *SCC OF O2 IN CABIN. BUDDY SYSTEM *SCC *PSE REQUIRED. VERIFY FOLLOWING NET RESPIRATORY EQUIPMENT AVAILABLE 105 FOR USE: ONE ELSA PER FLIGHT CREW MEMBER RECORD NO.__________ 15-0139 OTC CECL VERIFY CONTINUOUS MONITORING 132 OF O2 IN CABIN. 15-0140 LPS C1MC VERIFY (AWP05 PGB PAD A OR AWP06 PGB PAD B) HIMS 5982, 5987, 6377 AND 6378 DISPLAYED IN MIXED MODE. NON-LAUNCH PAD ECS TO REMOTE ---------------------------- NOTE PERFORM NEXT TWO STEPS IF ECS SUPPORTING VEHICLE OR PAYLOAD AT NON-LAUNCH PAD. 15-0141 OTC NTD VERIFY C-6 AND C-10 CONSOLE IN 232 NON-LAUNCH FIRING ROOM CONFIGURED NTD LPS TO SUPPORT ECS CONTROL STATION TRANSFER PAD TO FIRING ROOM. NOT PERFORMED ______ 15-0142 NTD OTC PERFORM NON-LAUNCH PAD ECS SU72557 232 CONTROL STATION TRANSFER PAD TO FIRING ROOM. REPORT COMPLETION. NOT PERFORMED ______ 543 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET TIR LOG ---------- 15-0143 TBC CMQC VERIFY ALL ET TIR LOG ITEMS SU72339 136 CLOSED. CMQC PQCG QV:_____ SRB CALL TO STATIONS -------------------- 15-0144 -09H00M TBC CPWR VERIFY PROGRAMS BSE03 AND BSE07 SU72579 136 INACTIVE AND WILL NOT BE CALLED UP DURING THIS OMI. 15-0145 TBC CBRS VERIFY PROGRAMS SSRB1, SSRB2, SSRB3, 136 AND SSRB5 INACTIVE AND WILL NOT BE CALLED UP DURING THIS OMI. SRSS GSE POWER-UP ----------------- 15-0146 TBC CBRS PERFORM RANGE SAFETY GSE SU72581 136 POWER UP. 15-0147 CBRS CURSOR CNTL (SWRB3) BSR01 - XMIT CURSOR POWER ON SYS A&B A PRIME - XMIT CURSOR 15-0148 CBRS CURSOR CNTL (BWR10) HOLDFIRE EMON ACT XMIT CURSOR KEY - PRESS 15-0149 CBRS TBC SRSS GSE POWER - UP COMPLETE. 136 544 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB POWER UP ------------ 15-0150 NTD TBC PERFORM SRB OI BUS A AND B POWER SU72583 232 APPLICATION AND MDM INITIALIZATION TBC CPWR PER OMI S9001VL1 USING OPTION A 136 CBDP ON CH 176. RT OMI LOG NO.__________ 15-0151 OTC CEPD PERFORM MEC PREFLT BITE EVALUATION. 132 15-0152 CEPD PERFORM CDS QLDB RETRIEVAL ON FD VERIFY NO MEC FAILURES NOTE PERFORM NEXT STEP IF TAIR TRAILER WAS AT PAD. 15-0153 -09H00M GBHE STM TAIR TRAILER NO. _____ MOVE FROM HESA 111 PAD - _____ TO _____ COMPLETE. SU72596 STM NTD 232 NTD OTC NOT PERFORMED ______ 15-0154 NTD STM K-9 SPECIALIST PROCEED TO TOP SEC 232 OF PAD AND STANDBY. PERFORM SU72558 | STM JSTC SWEEP OF PAD APRON AFTER 111 RSS/FSS CLEARED OF NONESSENTIAL JSTC *SEC PERSONNEL. 114 545 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAD CLOSEOUT VALVE POSITIONING - ------------------------------ COMPLETE -------- 15-0155 JBPN STM PAD CLOSEOUT VALVE POSITIONING PNSA 111 COMPLETE. PNU STM JSTC SU72600 JSTC GSPN SU72662 114 15-0156 QBSE STM WIRE ROPES AND SIGNS AT FLAME STSA | NET TRENCH SOUTH AND TEMPORARY ROPES SU72500 104 AND SIGNS AROUND FLAME TRENCH STM NTD NORTH HAVE BEEN REMOVED. 232 T:______ PAV DELIVERY TO SLIDEWIRE BUNKER -------------------------------- COMPLETE -------- 15-0157 *SCB JSTC ALL PORTABLE AIR VENTILATORS LS JSTC STM NOT REQUIRED BY FLIGHT CREW 111 DELIVERED TO PAD SLIDEWIRE BUNKER. STM NTD 232 CLEAR PAD FOR ET LOADING ------------------------ 15-0158 NTD CMQC VERIFY ALL APPENDIX K ITEMS HAVE SU72553 CLEARED. 15-0159 -09H00M NTD OTC CLEAR ALL PERSONNEL NOT HAZ SU72608 232 TBC BADGED FROM PAD ___ FOR LOX/LH2 STM LOADING. *SCC *SCC *PSE NET 105 546 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0160 NTD *ACM PERFORM COMMUNICATIONS CHECK VIA NET RADIO NET 110 WITH BADGEBOARD OIC. 110 NON STANDARD HAZ BADGE REQUESTS MUST BE APPROVED BY NTD/SAFETY. NOTE NEXT THREE STEPS ARE FOR | NON-LAUNCH PAD. 15-0161 NTD STM VERIFY NON-LAUNCH PAD VALVE 232 RECONFIGURATIONS COMPLETE. 15-0162 NTD CTC NON-LAUNCH PAD WILL BE CLEARED SU72566 232 STM MOMENTARILY. VERIFY PERSONNEL SU72602 *SCC COMPLETE WITH ALL OPERATIONS AT NON-LAUNCH PAD. 15-0163 NTD ATTENTION ON PAD___: PA ALL PERSONNEL AT PAD___ CLEAR TO ROADBLOCK A/B-11 FOR LOX/LH2 LOADING. 15-0164 NTD STM ESTABLISH PAD SCREENING SEC 232 ROADBLOCKS B-3, B-4 (PAD B SU72590 | STM JSTC LAUNCH) OR A-3, A-5, A-6, A/B-4 111 (PAD A LAUNCH). | JSTC *SEC 114 547 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0165 -09H00M NTD ATTENTION ON PAD ___: PA ALL PERSONNEL NOT MANLOADED WITH HAZ BADGE, CLEAR PAD ___ TO ROADBLOCK A/B-11 FOR LOX/LH2 LOADING. NOTE NPM PERSONNEL MAY ENTER OTHER HAZ BADGE AREAS AS REQUIRED FOR SITUATIONAL MANAGEMENT. ESSENTIAL PERSONNEL ------------------- LH2 FINAL PREP CREW (HAZ BADGE) ------------------------------- SFOC NASA JBOSC ---- ---- ----- ENGR 2 1 TECH 4 SAFETY 1 1 FIRE 4 LO2 FINAL PREP CREW (HAZ BADGE) ------------------------------- SFOC NASA JBOSC ---- ---- ----- ENGR 2 1 TECH 4 SAFETY 1 1 FIRE 4 548 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0165 CREW MODULE AND WHITE ROOM CON'T -------------------------- CREW (HAZ BADGE) ---------------- ORB NASA SFOC --- ---- ---- TECH 4 QC 1 1 ASP 2 *PAD 1 SAFETY 1 1 BDA FINAL CLEAR OPS/SAFETY WALKDOWN ----------------------------------- (HAZ BADGE) ----------- NASA SFOC JBOSC ---- ---- ----- NPM 3 SAFETY 1 2 SECURITY 12* DEBRIS ENGR 1 PAD TECH 1 MLP TECH 1 * SECURITY PERSONNEL MANLOADED FOR BDA CLEAR OPS ONLY, THEY DO NOT SUPPORT WALKDOWN PTCR/ECS ROOM PRESSURIZATION (HAZ BADGE) ---------------------------------------- GSS NASA SFOC --- ---- ---- SUPR/ ENGR 2 1 QUAL 1 TECH 2 4 SAFETY 1 1 549 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0165 GVA FINAL ACTIVATION (HAZ BADGE) CON'T -------------------------------- SFOC NASA ---- ---- ENGR 2 TECH 3 SAFETY 1 1 REMOVE NON-FLIGHT ITEMS FROM CREW CMPT -------------------------------------- 15-0166 -09H00M OTC *PAD REMOVE ALL NON-FLIGHT ITEMS SU72561 132 (SUCH AS ENSOLITE PADS, DROP LIGHTS, EMERGENCY LIGHTS AND ALARMS) EXCEPT THOSE RECORDED IN TIR SYSTEM (SUCH AS RHC COVERS, AIRLOCK SOFT COVERS, A15 SOFT COVER, MIDDECK FLOOR COVERS AND BUMPER PAD ASSY ON ESCAPE POLE). REPORT COMPLETION. T:______ 550 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- COMM CMD TO LAUNCH CONFIG-MCCH ------------------------------ 15-0167 CCSE GEMA VERIFY MONITORING PERSONNEL ON 155 STATION IN FCA VAN AND AT EMC. VERIFY AMS ACTIVATED AND RUNNING. MONITOR FOR RF EMISSIONS NEAR FOLLOWING FREQUENCIES FOR REMAINDER OF COUNTDOWN. 2041.9 MHZ 2106.4 MHZ 2217.5 MHZ 2250.0 MHZ 2287.5 MHZ 243.0 MHZ 259.7 MHZ 279.0 MHZ 296.8 MHZ NOTE DO NOT BEGIN NEXT STEP UNTIL RSS IS IN PARK POSITION. 15-0168 -09H00M NTD *FLT PERFORM COMM CMD TO LAUNCH SU72568 232 *MIL CONFIG (NASA MCCH OPTION) JRPS PER OMI V1117 ON OIS CH 214. LPS (2 HR) OTC OTC CCSE RT OMI LOG NO.__________ 132 RCRE OMRS S00FA0.372-A OMRS S00FA0.372-D OMRS S00FA0.372-H OMRS S00FA0.372-I OMRS S00FB0.281-A-1R OMRS S00FB0.281-B-1R OMRS S00FB0.281-C-1R OMRS S00FB0.281-D-1R 551 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IUS RIMU CAL AND ALIGN COMPLETE | -------------------------------- | | NOTE | | PERFORM NEXT STEP FOR | IUS MISSION (STS-93). | | PERFORM NEXT STEP AT L-14H05M. | | 15-0169 ICTC PTC IUS RIMU CAL AND ALIGN COMPLETE. | 134 IUS NOW IN GYRO COMPASS MODE. | PTC NTD QUIET TIME NO LONGER REQUIRED. | 232 | OMRSD P018JC.010 | OMRSD P018JB.035-C | | NOT PERFORMED ______| 552 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- STANDBY GN2 (HAND VALVE OPEN) ----------------------------- OPERATIONS COMPLETE ------------------- 15-0170 -09H00M CPVD OTC STANDBY GN2 MODE (OPTION A) HAND SU72549 132 VALVE OPEN OPS COMPLETE. ECS OTC NTD PERSONNEL CLEARING PAD ECS ROOM 232 TO ROADBLOCK A/B-11. NTD *SCC *SCC *PSE NET 105 15-0171 -09H00M NTD *SCC CLEAR ALL PERSONNEL FROM ECS 232 ROOM. INSTALL SAFETY WARNING *SCC *PSE SIGNS ACROSS ECS SOUTH DOOR AND NET PTCR GROUND LEVEL DOOR AFTER 105 DOORS CLOSED AND SECURED. 15-0172 *PSE *SCC ALL PERSONNEL CLEAR OF ECS NET ROOM. YOU HAVE SAFETY CONCURRENCE 105 TO PRESSURIZE PTCR AND ECS ROOM. *SCC NTD 232 553 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRESS PTCR/ECS ROOM ------------------- NOTE PTCR/ECS ROOM WILL BE PRESSURIZED WITH AIR WHEN ECS GROUND LEVEL DOORS ARE CLOSED. 15-0173 -09H00M NTD STM PRESSURIZE PTCR AND ECS ROOM HVAA 232 PER OMI M3034. (30 MIN) SU72551 STM JBAC SU72593 111 ESSENTIAL PERSONNEL (HAZ BADGE) ------------------------------- GSS NASA SFOC --- ---- ---- SUPR/ ENGR 2 1 QUAL 1 TECH 4 SAFETY 1 1 15-0174 *PSE *SCC ALL SAFETY SIGNS INSTALLED AT ECS NET SOUTH DOOR AT PTCR GOUND LEVEL 105 DOOR. *SCC NTD 232 15-0175 JBAC STM PTCR AND ECS ROOM PRESSURIZED. HVAA | 111 STM NTD 232 554 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONTINGENCY CREW VERIFICATIONS | ------------------------------ | | 15-0176 STM JSTC VERIFY THE FOLLOWING PERSONNEL JSTC | 111 PSTM AVAILABLE FOR CONTINGENCY | CREW OPERATIONS. AIR-PACK | CERTIFICATIONS REQUIRED. | | TIME EFFECTIVITY: T-8H45M TO | T-6H AND COUNTING | | GROUP SUPERVISORS/ TECHS | ----- ENGINEERS ----- | ------------ | HVAC 1 2 CHVA | LOW VOLTAGE ELEC 1 1 PWRB | SPECIAL POWER 1 PWRA | PNEUMATICS 2 4 PWR | ELEVATORS 1 2 CDPD | SS & FX WATER 1 3 CWSS | FACILITY QUALITY 2 CPNS | HEAVY EQUIPMENT 1 6 HESA | FACILITY STRUCTURES 1 3 STE | J-BOSC 60 HZ POWER 1 2 ELEC | J-BOSC FIRE ALARMS 2 FA | | AIR TO GN2 CHANGEOVER (LPS) --------------------------- 15-0177 NTD STM SUPPORT ORBITER ECS AIR TO GN2 PNU 232 CHANGEOVER. GSPN CONTACT CPVD SU72535 STM JSTC ON CH 172 TO COORDINATE CHANGEOVER 111 PER OPERATION INSTRUCTIONS OF JSTC GSPN M3703. 114 15-0178 -08H30M OTC NTD VERIFY SAFETY CONCURRENCE TO PROCEED 232 WITH AIR TO GN2 CHANGEOVER. NTD *SCC *SCC *PSE NET 105 555 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0179 *PSE *SCC PAD SURFACE AND ABOVE (INCLUDING SU72537 NET PTCR AND ECS ROOM) CLEAR OF ALL SU72609 105 NONESSENTIAL PERSONNEL. YOU HAVE *SCC NTD SAFETY CONCURRENCE TO PROCEED 232 WITH AIR TO GN2 CHANGEOVER. NTD STM OTC TBC PTC WARNING GN2 WILL FLOW INTO ORBITER FWD PAYLOAD BAY AND AFT FUSELAGE. BREATHING OF NITROGEN GAS FROM ORBITER COMPARTMENT PURGE CAN BE LETHAL. 15-0180 -08H30M OTC CPVD PROCEED WITH ECS AIR-TO-GN2 132 CHANGEOVER PER OMI V1122 "AIR-TO-GN2" STANDBY MODE/AIR TO GN2 CHANGEOVER OPTION B - GN2 CHANGEOVER". COORDINATE WITH GSPN ON OIS CH 172. REPORT COMPLETION. (30 MIN) RT OMI LOG NO.__________ 556 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0181 -08H30M NTD ATTENTION ON PAD ___: PA ORBITER AIR-TO-GN2 PURGE CHANGEOVER WILL BEGIN MOMENTARILY. GN2 PURGE WILL BE APPLIED TO AFT FUSELAGE, PAYLOAD BAY AND FWD PLENUM FUSELAGE. 15-0182 NTD STM AIR TO GN2 CHANGEOVER IN PWRA | 232 PROGRESS. POSSIBILITY OF LOW STM JBEP LEVEL O2 ALARM. ADVISE STM 111 IF ALARMS OCCUR. NOTE THE MINIMUM TIME FOR GN2 PURGE PRIOR TO ET CRYOGENIC LOADING IS 30 MINUTES. VERIFIED BY CPVD LATER IN THIS SEQUENCE. MID FUS/PLB/AFT PURGE INERTED AND MAINTAINED AT LESS THAN 1 PCT O2. VERIFIED BY CHGD LATER IN THIS SEQUENCE AND JUST PRIOR TO ET LOAD IN SEQ 16. PURGE MOISTURE CONTENT IS LESS THAN 5 GRAINS/LB PRIOR TO ORBITER MPS CHILLDOWN. (ESTIMATE 1 1/2 HOURS FROM THE INITIAL START OF ECS GN2 PURGE). VERIFIED BY CPVD IN SEQ 16, PRIOR TO ET LO2/LH2 LOADING. 15-0183 CPVD OTC ECS AIR TO GN2 CHANGEOVER SU72535 132 CHGD (OPTION B) COMPLETE (V1122). ORBITER OTC NTD BEING PURGED WITH GN2 AT __________ 232 (RECORD TIME). NTD *SCC 557 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORBITER PAYLOAD BAY PURGE | ------------------------- | VERIFICATION | ------------ | | NOTE | | PERFORM THE FOLLOWING STEP | FOR STS-93. | | 15-0184 PTC OTC AFTER CIRCUIT STABILIZES PERFORM | 132 ORBITER OPERATION SUPPORT SETUP 15 - | OTC CPVD PAYLOAD BAY PURGE VERIFICATION. | | NOTIFY PTC IMMEDIATELY IF PURGE | GOES OUT OF SPEC. (STS-93) | | NOT PERFORMED ______| | 15-0185 -08H30M CPWR TBC SRB OI BUS A&B POWER APPLICATION 136 COMPLETE. TBC NTD 232 558 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IUS RIMU CAL/ALIGN STATUS | ------------------------- | | NOTE | | PERFORM NEXT STEP FOR | IUS MISSION (STS-93). | | PERFORM NEXT STEP AT L-13H35M. | | IF CONTINGENCY CAL AND ALIGN | ON IUS NAV SYSTEMS IS REQUIRED, | IT WILL BE INITIATED AT | CONCLUSION OF ET LH2/LO2 | TANKING. | | 15-0186 ICTC PTC REPORTING SUCCESS/FAIL CRITERIA | 134 OF RIMU CAL AND ALIGNMENT. | PTC NTD CONTINGENCY RIMU CAL AND ALIGN | 232 WILL/WILL NOT BE REQUIRED. | | NOT PERFORMED ______| | 559 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SEPARATE MDM POWER SUPPLIES --------------------------- 15-0187 TBC CDPS SEPARATE MDM POWER SUPPLIES 136 FOR SRB HPU BITE TEST. 15-0188 CDPS CURSOR CNTL (SAS01 PGB) DPS XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS01 PGB) SRB MANUAL TEST SEL XMIT CURSOR KEY - PRESS PFK2 KEY - PRESS 15-0189 CDPS CURSOR CNTL (BSM06 PGB) SEPARATE MDM P/S XMIT CURSOR KEY - PRESS CRT (BSM06 PGB) ALL MDM P/S SEP SWITCHES ON 15-0190 CDPS PFP (BSM06) TERMINATE - PRESS 15-0191 CDPS TBC MDM POWER SUPPLIES SEPARATED. 136 560 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB HPU BITE TEST AND HPU FUEL ------------------------------ PUMP BEARING SEAL SOAK ---------------------- 15-0192 CBHY TBC REQUEST SFOC SAFETY CLEAR ALL SU72584 136 PERSONNEL FROM CONTROL AREA 25 FT SU72606 TBC NTD RADIUS AROUND HPU EXHAUST DUCTS 232 ON MLP ZERO LEVEL AND VERIFY NTD *SCC CONCURRENCE TO PROCEED. *SCC *PSE NET 105 15-0193 NTD ATTENTION ON PAD____: PA SRB HPU BITE TEST WILL BE PERFORMED. ALL PERSONNEL CLEAR AREA 25 FT RADIUS OF SRB HPU EXHAUST DUCTS ON MLP ZERO LEVEL. 15-0194 *PSE *SCC HPU EXHAUST DUCT CONTROL AREA NET CLEARED AND YOU HAVE SAFETY 105 CONCURRENCE TO PROCEED. *SCC NTD 232 NTD TBC WARNING HAZARDOUS STEPS FOLLOW DUE TO SRB HPU BITE TEST. 15-0195 TBC CBHY CONTROL AREA CLEARED. 136 PERFORM SRB HPU BITE TEST AND HPU FUEL PUMP BEARING SEAL SOAK PER SRB OPERATION SUPPORT SETUP 4. 561 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET OI INSTRUMENTATION AND ET LEVEL ---------------------------------- SENSOR CHECKS ------------- 15-0196 TBC OTC REQUEST CMPS, CMPL AND CISL SU72576 132 SUPPORT ON CH 136. OTC CISL CMPS CMPL 15-0197 TBC CISL PERFORM ET OI INSTRUMENTATION CHECKS 136 CMPS AND PERFORM SRM CASE TEMP EMON CMPL ACTIVATION ON CH 145 PER S0007VL4 (SEQ 38). (20 MIN) SEP CAMERA HEATERS ACTIVATION ----------------------------- NOTE PERFORM NEXT TWO STEPS IF SEP CAMERAS INSTALLED. 15-0198 OTC CISL PERFORM SEP CAMERA HEATER SU72565 132 ACTIVATION PER S0007VL4 (SEQ 38) (5 MIN) NOT PERFORMED ______ 15-0199 CISL OTC SEP CAMERA HEATER ACTIVATION COMPLETE. 132 NOT PERFORMED ______ 562 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 FR CONFIG FOR LOADING (G3251) --------------------------------- NOTE DO NOT PERFORM NEXT STEP IF SUPPORTING SCRUB TURNAROUND. 15-0200 TBC CLHY PERFORM OMI G3251 OPERATION SUPPORT 136 SETUP 8 - LH2 FIRING ROOM CONFIGURATION FOR LOADING. NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF SUPPORTING SCRUB/TURNAROUND. 15-0201 TBC CLHY PERFORM FIRING ROOM CONFIGURATION 136 FOR LOADING PER OMI G3255. NOT PERFORMED ______ 15-0202 *PSE *SCC ALL NON HAZARD BADGE PERSONNEL NET CLEARED FROM PAD___ FOR LOX/LH2 105 LOADING OPERATIONS. *SCC NTD 232 NTD OTC TBC STM 563 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VERIFY FIRING ROOM CONSUMABLES | ------------------------------ | 15-0203 -08H30M LPS VERIFY FIRING ROOM CONSUMABLES. | 15-0204 -08H30M NTD STM FIRE SUPPORT REQUIRED ON FIRE 232 STATION IN 30 MINUTES AT LO2 SU72594 STM JSTC FACILITY AND LH2 FACILITY. EMS ON 111 STANDBY AT FIRE STATION 2. JSTC JFIR 114 30 MIN NOTICE FOR WRECKER AT PAD -------------------------------- GATE ---- 15-0205 -08H30M JSTC WGSA PROVIDE WRECKER AT PAD GATE. SU72595 (T-8 HOURS TO T-6 HOURS) (7-4905) SU72663 VERIFY WHEN ON-SITE. 15-0206 JSTC *SEC SECURITY REPORT WHEN WRECKER SEC 114 ON SITE AT PAD GATE. 564 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 FR CONFIG FOR LOADING COMPLETE ---------------------------------- NOTE DO NOT PERFORM NEXT STEP IF SUPPORTING SCRUB/TURNAROUND. 15-0207 CLHY TBC G3251 OPERATION SUPPORT SETUP SU72578 136 8 - LH2 FIRING ROOM CONFIGURATION TBC NTD FOR LOADING COMPLETE. 232 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF SUPPORTING SCRUB/TURNAROUND. 15-0208 CLHY TBC FIRING ROOM CONFIGURATION FOR 136 LOADING PER G3255 COMPLETE. TBC NTD 232 NOT PERFORMED ______ 565 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WEATHER UPDATE - ET TANKING PREPS --------------------------------- 15-0209 -08H15M STM JBDY REQUEST CURRENT WEATHER SU72580 111 INFORMATION FOR LAUNCH PAD. JBDY *WEA ADVISE AND UPDATE WEATHER ADVISORIES 231 AND WARNINGS AS RECEIVED. 15-0210 *WEA JBDY WEATHER INFORMATION FOR ET TANKING/ 231 DETANKING. JBDY STM 111 1. FORECAST TIME__________ STM NTD 232 *SCC 2. FORECAST VALID_________ NTD TBC TBC CLOX 3. PROBABILITY OF PRECIP__________ 136 CLHY 4. PROBABILITY OF LIGHTNING/ELECTRICAL STORMS WITHIN 5 NM OF PAD _________ (0 PCT PRIOR TO START, LESS THAN 20 PCT FOR FIRST HOUR) 5. RELATIVE HUMIDITY__________ 6. WINDS SS/GUSTS__________ DIRECT__________ (NO WINDS > 42 KNOTS AT 60 FT LVL DURING TANKING/DETANKING) 7. TEMPERATURE__________ OMRSD S00L00.030-1 OMRSD S00L00.080-1 ET OI INST CKS COMPLETE ----------------------- 15-0211 -08H10M CISL TBC ET OI INSTRUMENTATION CHECKS AND SU72576 136 SRM CASE TEMP EMON ACTIVATION COMPLETE. 566 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET LEVEL SENSOR CKS ------------------- 15-0212 -08H10M TBC CMPS PERFORM ET LEVEL SENSOR CHECKS SU72582 136 ON CH 168 PER S0007VL4 (SEQ 41). (10 MIN) 15-0213 CMPS TBC LEVEL SENSOR CHECKOUT WILL BE 136 CLOX PERFORMED AT THIS TIME. MOMENTARY CLHY LOSS OF POWER TO ET OI LEVEL SENSORS, ULLAGE PRESSURES AND VENT VALVE INDICATORS WILL OCCUR. 15-0214 -08H00M CMPS TBC ET LEVEL SENSOR CHECKS COMPLETE. 136 CLOX ET LEVEL SENSOR, ULLAGE PRESSURE CLHY TRANSDUCER AND VENT VALVE POSITION INDICATORS ARE NOW VALID. SRB JOINT HEATER ACTIVATION --------------------------- 15-0215 -08H00M TBC CPWR PERFORM SRB JOINT HEATER POWER SU72643 136 APPLICATION. CAUTION AT NO TIME ARE RSRM JOINT TEMPS TO EXCEED 123 DEG F OR IGNITER HEATER TEMPS TO EXCEED 125 DEG F. AT NO TIME ARE JOINT HEATER CURRENTS TO EXCEED 19.5 AMPS OR IGNITER HEATER CURRENTS TO EXCEED 4.9 AMPS. 15-0216 CPWR CURSOR CNTL (BDE11) AUTO SEQ - ALL XMIT CURSOR KEY - PRESS CRT (BDE11) VERIFY ALL HTR PWR ON ALL AUTO SEQ ACT OMRSD S00FA0.610-1R OMRSD S00FA0.970 567 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT STEP IF IGNITER HEATERS WERE POWERED UP AT L-18H00M. 15-0217 THE PREVIOUS STEP SATISFIES THE FOLLOWING OMRS REQUIREMENTS. OMRSD S00FA0.620-1R OMRSD S00FA0.960 NOT PERFORMED ______ 15-0218 CPWR TBC SRB FIELD JOINT HEATER POWER 136 APPLICATION COMPLETE. TBC NTD 232 15-0219 STM JBWC SOUND SUPPRESSION WATER TECHS WSSA 111 REQUIRED ON SITE IN 30 MINUTES TO REMOVE LOCKS AND OPEN VALVES. 15-0220 STM JSTC DELIVER 12 LAPS WITH COMM TO LS 111 FIRE STATION NO. 2. JSTC *SCB NET 104 568 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VERIFY SUPPORT (FIRE COMBAT/EMS/SAFETY) --------------------------------------- 15-0221 -08H00M NTD *SCC VERIFY FIRE COMBAT CREWS ON FIRE 232 STM STATION AT LO2 AND LH2 FACILITIES STM JSTC TO SUPPORT LO2/LH2 FINAL PREPS 111 FOR CRYO LOAD. EMERGENCY MEDICAL JSTC JFIR SERVICES ON STANDBY AT FIRE 114 STATION NO. 2. 15-0222 JFIR JSTC FIRE SUPPORT ON STATION TO FIRE 114 SUPPORT FINAL PREPS FOR CRYO LOAD. JSTC STM EMERGENCY MEDICAL SERVICES ON 111 STANDBY AT FIRE STATION NO. 2. STM NTD HAVE FIRE AND EMS PERFORM COMM 232 CHECK WITH NTD, *SCC AND *PSE NTD *SCC ON RADIO NET 105. LO2 FINAL PREPS --------------- NOTE GVA ALIGNMENT MUST BE COMPLETE AND AREA CLEAR OF PERSONNEL PRIOR TO NEXT STEP. 15-0223 -08H00M NTD TBC PERFORM LOX STORAGE TANK SU72647 232 PRESSURIZATION AND SUCTION LINE TBC CLOX CHILLDOWN PER OMI G3151 (OR 136 OMI G3155 FOR SCRUB TURNAROUND). 15-0224 TBC JYVR START VIDEO RECORDING OF OTV COMM 138 CAMERAS FOR LOX/LH2 FINAL PREPS (G3151 AND G3251). (SEE CLHY AND CLOX, FIGURE 4) CAMERAS: 003/103,007/107,009/109,031/131, 032/132,038/138,039/139,040/140, 046/146,047/147,052/152,053/153, 056/156 569 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0225 CLOX TBC READY TO CLEAR LOX CONTROL AREA SU72680 136 FOR G3151 (OR G3155) HAZARDOUS TBC NTD OPERATIONS - STORAGE TANK 232 PRESSURIZATION. 15-0226 NTD *SCC PERFORM FOLLOWING: 232 TBC TBC CLOX 1. CLEAR NONESSENTIAL PERSONNEL 136 150 FT RADIUS FROM STORAGE AREA CLOX PLOX FOR G3151/G3155 OPERATIONS. 156 ESSENTIAL PERSONNEL ARE AS FOLLOWS: PLOX LOX STORAGE AREA, ROVING LOX LEAD ENGR PLO2 LOX STORAGE AREA, LOX SYS ENGR PLO4 LOX STORAGE AREA, LOX TECH PLO5 LOX STORAGE AREA, LOX TECH PLO6 LOX STORAGE AREA, LOX TECH PLO7 LOX STORAGE AREA, LOX TECH *PSE SFOC SAFETY ENGR PNQC PAD, QC (NASA) PNLO PAD, LOX ENGR, (NASA) 2. VERIFY FIRE SUPPORT ON-SITE AT PAD AND EMERGENCY MEDICAL ON STANDBY AT FIRE STATION 2. PLOX PERFORM COMM CHECK WITH FIRE SUPPORT AND *SCC ON RADIO NET 105/205. VERIFY LOX STORAGE AREA WARNING LIGHTS ON, FLASHING AMBER. 3. COVERALLS, FACESHIELDS, NON SPARKING FOOTWEAR, AND GLOVES REQUIRED FOR MANUAL LOX VALVE OPERATORS. ALL OTHERS REQUIRE COVERALLS. 570 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0227 NTD ATTENTION ON PAD___: PA ALL NONESSENTIAL PERSONNEL CLEAR 150 FOOT RADIUS OF LOX STORAGE AREA FOR HAZARDOUS OPERATIONS. 15-0228 PLOX CLOX CONTROL AREA ESTABLISHED AND 156 WARNING LIGHTS ON, FLASHING AMBER. CLOX TBC NONESSENTIAL PERSONNEL ARE CLEAR 136 AND ESSENTIAL PERSONNEL ARE PROPERLY TBC NTD ATTIRED. FIRE SUPPORT ON SITE AND 232 EMERGENCY MEDICAL ON STANDBY. NTD *SCC REQUEST SAFETY CONCURRENCE TO PROCEED WITH STORAGE TANK PRESSURIZATION. 15-0229 *SCC NTD YOU HAVE SAFETY CONCURRENCE TO 232 PROCEED WITH STORAGE TANK NTD TBC PRESSURIZATION. TBC CLOX 136 CLOX PLOX 156 ET LH2 PREPS COMPLETE --------------------- NOTE DO NOT PERFORM NEXT STEP IF SUPPORTING SCRUB TURNAROUND. 15-0230 CLHY TBC ET LH2 PREPS PER G3251 SU72652 136 COMPLETED. TBC NTD 232 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF SUPPORTING SCRUB TURNAROUND. 15-0231 CLHY TBC ET LH2 PREPS PER G3255 COMPLETE. 136 TBC NTD 232 NOT PERFORMED ______ 571 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 FINAL PREPS --------------- 15-0232 CLHY TBC READY TO CLEAR CONTROL AREA FOR SU72651 136 G3251 (OR G3255) LH2 FINAL PREPS, TBC NTD HAZARDOUS OPERATIONS. 232 15-0233 NTD TBC PERFORM FOLLOWING: SU72681 232 TBC CLHY 1. CLEAR NONESSENTIAL PERSONNEL 136 200 FT RADIUS FROM STORAGE CLHY PLHY AREA FOR G3251/G3255 166 OPERATIONS. ESSENTIAL PERSONNEL ARE AS FOLLOWS: PLHY LH2 STORAGE AREA, ROVING LH2 LEAD ENG PLH2 LH2 STORAGE AREA, LH2 SYS ENG PLH4 LH2 STORAGE AREA, LH2 TECH PLH5 LH2 STORAGE AREA, LH2 TECH *PSE SFOC SAFETY ENG PNQC PAD, QC (NASA) PNLH PAD, LH2 ENG, (NASA) 2. VERIFY FIRE SUPPORT ON-SITE AND LH2 STORAGE AREA WARNING LIGHTS ON, FLASHING AMBER. 3. COVERALLS, FACESHIELDS, NON SPARKING FOOTWEAR, AND GLOVES REQUIRED FOR MANUAL LH2 VALVE OPERATORS. ALL OTHERS REQUIRE COVERALLS. 15-0234 PLHY CLHY VERIFY EMERGENCY MEDICAL SUPPORTS 166 ON STANDBY AT LC-39 FIRE STATION CLHY TBC NO. 2 AND CRASH TRUCK-CFR ON SITE 136 AT LH2 STORAGE AREA. TBC NTD NTD *SCC 232 15-0235 NTD ATTENTION ON PAD ___: PA ALL NONESSENTIAL PERSONNEL CLEAR 200 FT RADIUS OF LH2 STORAGE AREA FOR HAZARDOUS OPERATIONS. 572 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0236 PLHY CLHY CONTROL AREA ESTABLISHED AND 166 WARNING LIGHTS ON, FLASHING CLHY TBC AMBER. NONESSENTIAL PERSONNEL 136 CLEAR AND ESSENTIAL PERSONNEL TBC NTD PROPERLY ATTIRED. FIRE 232 SUPPORT ON SITE AND EMERGENCY NTD *SCC MEDICAL ON STAND BY. NOTE DO NOT PERFORM NEXT STEP IF SUPPORTING SCRUB/TURNAROUND. 15-0237 NTD TBC PERFORM OMI G3251 OPERATION SUPPORT 232 SETUP 14 - LH2 FINAL PREPS FOR TBC CLHY LOADING. 136 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF SUPPORTING SCRUB/TURNAROUND. 15-0238 NTD TBC PERFORM LH2 FINAL PREPS FOR VEHICLE 232 LOADING PER OMI G3255. TBC CLHY 136 NOT PERFORMED ______ 573 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLOSE ALL FRAMES ---------------- 15-0239 -08H00M STM GYCC CLOSE ALL FRAMES. COMM 111 CONFIG CREW COMPARTMENT ----------------------- AND WHITE ROOM -------------- NOTE DO NOT PERFORM NEXT STEP IF BUS SENSORS ALREADY IN MONITOR POSITION. 15-0240 OTC ASP PANEL R1 SU72637 132 POWER DISTRIBUTION AC BUS SNSR 1 SW - OFF, 1 SEC, MONITOR 2 SW - OFF, 1 SEC, MONITOR 3 SW - OFF, 1 SEC, MONITOR NOT PERFORMED ______ NOTE PERFORM NEXT TWO STEPS IF THE MINICAMS ARE TO BE USED FOR STRAP-IN. 15-0241 OTC ASP VERIFY MINICAMS CONNECT TO J4 132 AND J5 AT OTV INTERFACE IN OAA CEILING. NOT PERFORMED ______ 15-0242 OTC STM VERIFY ACCEPTABLE VIDEO SIGNAL COMM 132 FROM OAA INTERFACE FROM PAD A/ STM JYVO PAD B. VERIFY VIDEO SIGNAL IS 138 PATCHED TO OTV SWITCHER AS SOURCES 068/168 AND 069/169. NOT PERFORMED ______ 15-0243 NTD STM VERIFY PAD WHITE ROOM 02 PWRA | 232 ANALYZER READOUTS NORMAL AT STM JBEP C-2 CONSOLE. 111 574 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT TWO STEPS IF FIXED O2 SYSTEM IN CREW COMPARTMENT IS VERIFIED INSTALLED AND OPERATIONAL. 15-0244 -08H00M NTD VERIFY PORTABLE O2 METER IN WHITE ROOM CONFIGURED FOR VIEWING ON OTV. NOT PERFORMED ______ 15-0245 *PSE *SCC PORTABLE O2 METER HAS BEEN INSTALLED NET IN WHITE ROOM AND VERIFIED READABLE 105 BY OTC. *SCC NTD 232 NOT PERFORMED ______ 15-0246 OTC JYVR START VIDEO RECORDING OF OTV COMM 138 CAMERA 005/105. SU72664 15-0247 -08H00M OTC OMTO WHITE ROOM CEILING: 132 1. VERIFY ORBITER ECS DAMPER A122817 IS OPEN AND AIR IS FLOWING THRU ECS DUCT INTO CREW COMPARTMENT. 2. VERIFY CHAMBER ECS DAMPER A122818 IN MARKED POSITION. T:______ 15-0248 OTC OMTO VERIFY ECS EXHAUST LOUVERS OPERATE 132 FREELY BY MANUALLY PUSHING THEM OUTBOARD TO OPEN THEN RELEASING THEM TO CLOSE. T:______ 15-0249 OTC CECL VERIFY PARTIAL PRESSURE OF OXYGEN 132 IN CREW COMPARTMENT SATISFACTORY. 575 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- HGDS CONFIDENCE CHECKS COMPLETE ------------------------------- 15-0250 CHGD OTC HGDS, BUHGDS AND HUMS CONFIDENCE SU72543 132 CHECKS COMPLETE. SU72473 HGDS ---- TEST GAS CYCL NO. __________ BD GAS CERTIFIED VALUE (CV) ANALYZED VALUE TOLERANCE --- -------------------- -------------- --------- H2 __________ BD __________ CV +/- 60 HE __________ BD __________ CV +/- 60 O2 __________ BD __________ CV +/- 60 AR __________ BD __________ CV +/- 15 BUHGDS ------ TEST GAS CYCL NO. __________ BD GAS CERTIFIED VALUE (CV) ANALYZED VALUE TOLERANCE --- -------------------- -------------- --------- H2 __________ BD __________ CV +/- 100 HE __________ BD __________ CV +/- 1000 O2 __________ BD __________ CV +/- 100 AR __________ BD __________ CV +/- 30 OMRSD G51FGDMA0.060 OMRSD G61FGDMA0.060 OMRSD G51FGDMA0.095 OMRSD G61FGDMA0.095 OMRSD S00FA0.435 576 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0250 HUMS CON'T ---- GN2 TEST GAS CYLINDER NO. __________ BD GAS CERTIFIED VALUE (CV) ANALYZED VALUE TOLERANCE --- -------------------- -------------- --------- H2 __________ BD __________ CV +/- 100 HE __________ BD __________ CV +/- 1000 O2 __________ BD __________ CV +/- 100 AR __________ BD __________ CV +/- 30 GHE TEST GAS CYLINDER NO. __________ BD GAS CERTIFIED VALUE (CV) ANALYZED VALUE TOLERANCE --- -------------------- -------------- --------- H2 __________ BD __________ CV +/- 10 PCT N2 __________ BD __________ CV +/- 10 PCT O2 __________ BD __________ CV +/- 10 PCT AR __________ BD __________ CV +/- 10 PCT OMRSD GLWGGDMF0.004 (MLP-1) OMRSD GLVGGDMF0.004 (MLP-2) OMRSD GLUGGDMF0.004 (MLP-3) MLP HALON SYSTEM TO MANUAL -------------------------- 15-0251 -08H00M JSTC JFIR PLACE MLP HALON SYSTEM TO FIRE 114 MANUAL FROM 1P10 (REMOTELY). REPORT COMPLETION. 577 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- HARD COPY $HWMON ERRORS ----------------------- 15-0252 LPS C1MC HARD COPY ALL $HWMON ERRORS 127 AND HIM STATUS FOR BASELINE REFERENCE. CONFIGURE CONSOLES AB-5, AB-6, ------------------------------ AB-7 AND AB-8 OIS-D TO ---------------------- MULTI-CHANNEL TRANSMIT ---------------------- 15-0253 -08H00M STM GYCC CONFIGURE OIS-D COMMUNICATIONS COMM 111 IN PRIME CONTROL ROOM CONSOLES GYCC JYCD AB-5, AB-6, AB-7 AND AB-8 TO 117 MULTI-CHANNEL TRANSMIT CAPABILITY. (30 MIN) 15-0254 STM NTD OIS-D WILL BE CONFIGURED TO 232 MULTI-CHANNEL TRANSMIT MODE ON CONSOLES AB-5, AB-6, AB-7 AND AB-8. 578 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- BDA CLEAR FINAL OPS/SAFETY WALKDOWN ----------------------------------- WARNING ALL PERSONNEL WILL REMAIN FURTHER THAN 6 FT FROM UNPROTECTED EDGES ON MLP ZERO LEVEL. 15-0255 -08H00M NTD NPM PERFORM INTEGRATED OPERATION SU72641 NET SUPPORT SETUP 6 - BDA CLEAR FINAL 110 OPS/SAFETY WALKDOWN, INCLUDING REMOVAL 232 *SCC REMOVAL OF SFOC SAFETY SIGNS. (1 HR 30 M) NOTE NPM PERSONNEL MAY ENTER OTHER HAZ BADGE AREAS AS REQUIRED FOR SITUATIONAL MANAGEMENT. ESSENTIAL PERSONNEL ------------------- NASA SFOC JBOSC ---- ---- ----- DEBRIS ENG 1 NPM 3 SAFETY 1 1 SECURITY 12* PAD TECH 1 (* SECURITY PERSONNEL MANLOADED FOR BDA CLEAR OPS ONLY. THEY DO NOT SUPPORT WALKDOWN) SAFETY SIGN REMOVAL LIST ------------------------ 1. MLP A&B SIDE 1,2&4 AND ZERO LEVEL 2. PERIMETER ROAD AND F ROAD INTERSECTION 3. LOX AND LH2 TSM'S 4. PTCR PAD SURFACE NORTH AND SOUTH BLAST DOORS, AND NORTH BRIDGE. 5. FSS 75 FOOT LEVEL 579 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WATER CHILLER OPS ----------------- 15-0256 -08H00M JSTC JSAC VERIFY UTILITY ANNEX AC 114 REFRIGERATION PLANT READY TO SU72597 JSTC STM SUPPORT PER I3067. 111 15-0257 -07H45M CBHY TBC SRB HPU BITE TEST AND HPU FUEL 136 PUMP BEARING SEAL SOAK COMPLETE. OMRSD B42AP0.050-C-1R OMRSD B42AP0.060-C-1 OMRSD B42AP0.080-B-1R 15-0258 TBC NTD SRB HPU BITE TEST AND HPU FUEL SU72584 232 PUMP BEARING SEAL SOAK PER SRB NTD *SCC OPERATION SUPPORT COMPLETE. *SCC *PSE REQUEST SFOC SAFETY OPEN CONTROL NET AREA AROUND HPU EXHAUST DUCTS. 105 15-0259 *PSE *SCC HPU EXHAUST DUCT CONTROL AREA SU72606 NET OPEN FOR CONTROLLED WORK. 105 *SCC NTD 232 NTD TBC 580 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0260 CBHY CRT (BAT04) RECORD PRESENT TIME AND DATE TIME__________GMT DATE__________(MMDDYY) CRT (BAT04) SRB AFT SKIRT GN2 PURGE CURSOR CNTL T (BLOCK) XMIT CURSOR KEY - PRESS CRT NOTE DISPLAY OF FLEX BEARING TEMPERATURES AND NOZZLE TO CASE JOINT TEMPERATURES. RECORD FLEX BEARING TEMPERATURES ______B_______ DEG F BD ______B_______ DEG F BD ______B_______ DEG F BD ______B_______ DEG F BD RECORD NOZZLE CASE JOINT TEMPERATURES ______N_______ DEG F BD ______N_______ DEG F BD ______N_______ DEG F BD CURSOR CNTL T (BLOCK) XMIT CURSOR KEY - PRESS NOTE DISPLAY OF PURGE SCHEMATIC 581 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF ANY ONE OR MORE OF ABOVE SIX NOZZLE TO CASE JOINT TEMPERATURES WAS LESS THAN 78 DEG F. 15-0261 TBC CBHY ACTIVATE SRB GN2 AFT SKIRT PURGE 136 PER SRB OPERATION SUPPORT SETUP 5 - SRB AFT SKIRT GN2 PURGE ACTIVATION. NOT PERFORMED ______ SRB TVC POWER UP ---------------- 15-0262 TBC CAFC PERFORM SRB TVC POWERUP SU72644 136 15-0263 TBC OTC TRANSFER MEC RSYS TO C11 TO 132 SUPPORT SRB TVC POWER UP. OTC CEPD 15-0264 CEPD CONSOLE KYBD C CO MEC1 C11 XMIT CMD KEY - PRESS C CO MEC2 C11 XMIT CMD KEY - PRESS 15-0265 CEPD OTC MEC1 AND MEC2 RSYS TRANSFERRED 132 TO C11. OTC TBC TBC CAFC 136 15-0266 CAFC CURSOR CNTL (SAB19/SWB01) ATVC - OPS MAN XMIT CURSOR KEY - PRESS 582 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0267 CAFC CURSOR CNTL (SAB22/VWB35) SRB TVC PWR UP XMIT CURSOR KEY - PRESS 15-0268 CAFC CURSOR CNTL (SAB22/VWB35) START TEST XMIT CURSOR KEY - PRESS 15-0269 CAFC CRT (SAB22/VSB31) VERIFY INITIAL GNC SYSTEMS STATUS 15-0270 CAFC APPL PG (SAB22/VSB31) PFK1 KEY - PRESS (CONTINUE) 15-0271 CAFC CRT (SAB22/VTB01) VERIFY FINAL GNC SYSTEM STATUS DISPLAYED 15-0272 CAFC APPL PG (SAB22/VTB01) PFK1 KEY - PRESS (PERFORM POST POWER-UP TEST) NOTE NOTED REQUIREMENT IS SATISFIED BY THE FOLLOWING STEPS ANNOTATED WITH OMRS CODE. OMRS S00FA0.770 15-0273 CAFC CRT (SAB22/VWB35) VERIFY SRB TVC POWER UP COMPLETE WITHOUT ANOMALY OMRS S00FA0.770 (VTB01) 15-0274 CAFC APPL PG (SAB22/VWB35) PFK15 KEY - PRESS (TERM SAB22) 583 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- AI MODE 1 WITH SRB ------------------ 15-0275 CAFC PFP (SAB20/SWB02) PFPK (SWB02) - PRESS 15-0276 CAFC PFP (SWB02) PFPK 4 (ORB/SRB AI MODE 1) - PRESS OMRS S00FA0.770 (SWB02) 15-0277 NOTED REQUIREMENT COMPLETE. OMRSD S00FA0.770 15-0278 CAFC CRT (VWB03 PG-B) VERIFY ON SRB ACTUATORS THAT DIFFERENCE BETWEEN POSITION AND DRIVER OUTPUT NOT GREATER THAN 0.90 DEG. (1.13 IN.) ACTIVATE SRB TVC LCC EMON ------------------------- 15-0279 CAFC APPL PAGE A (SAB20/SWB02) PFK-13 KEY - PRESS (ACT EMON SETUP) 15-0280 CAFC CURSOR CNTL (SAB20/SWB02 PAGE A) A - SRB TVC XMIT CURSOR KEY - PRESS 15-0281 CAFC APPL PAGE A (SAB20/SWB02) PFK-13 KEY - PRESS (DEACT EMON SETUP) 15-0282 CAFC CONSOLE KYBD C CO MEC1 C10 XMIT CMD KEY - PRESS C CO MEC2 C10 XMIT CMD KEY - PRESS 15-0283 CAFC TBC MEC RSYS HAS BEEN REASSIGNED TO 136 C10. TBC OTC 132 OTC CEPD 584 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0284 CAFC TBC SRB TVC POWER UP, FUNCTIONAL 136 CHECK AND LCC ACTIVATION COMPLETE. TBC NTD 232 NOTE OBTAIN PREFLT BITE SPA PRINTOUT FROM CAFC FOR EVALUATION IN NEXT STEP. 15-0285 OTC CEPD PERFORM MEC PREFLT BITE SU72645 132 EVALUATION. 15-0286 CEPD VERIFY NO MEC FAILURES 15-0287 NTD *SEC IDENTIFY GSA VEHICLES AT PAD SEC 232 OPS BUILDING TO BE MOVED FOR LAUNCH. IF DRIVER AND/OR KEYS NOT AVAILABLE, REQUEST WRECKER FOR REMOVAL FROM PAD GATE. CONSOLES AB-5, AB-6, AB-7 AND AB-8 ---------------------------------- OIS-D CONFIGURATION TO MULTI-CHANNEL ------------------------------------ TRANSMIT - COMPLETE ------------------- 15-0288 JYCD GYCC CONSOLES AB-5, AB-6, AB-7 AND COMM 117 AB-8 IN PRIME CONTROL ROOM HAVE GYCC STM BEEN CONFIGURED TO MULTI-CHANNEL 111 TRANSMIT CAPABILITY. STM NTD 232 585 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0289 LRD BRD REPORT WEATHER STATUS FOR 135 RETRIEVAL FORCES. WEATHER CONDITIONS ARE: SEA STATE __________ SEA TEMP __________ AIR TEMP __________ WINDS __________ VISIBILITY __________ | 15-0290 LRD LD INITIAL STATUS INDICATES RETRIEVAL 135 FORCES/WEATHER GO FOR LAUNCH. CHECK GS2A FEP DATA SLOTS ------------------------- 15-0291 -07H30M TBC NTD DUMP GS2A FEP AND VERIFY AT 232 LEAST 14 AVAILABLE 100 SAMPLE NTD LPS PER SECOND SLOTS. RETAIN LPS C1SE OUTPUT ON STATION. (COMPARE WITH 127 PREVIOUS DUMP). 15-0292 -07H30M LPS NTD GS2A FEP DUMP COMPLETE. FEP CONTAINS 232 _____________ AVAILABLE 100 SAMPLE NTD TBC PER SECOND SLOTS. CTPE TBC CLOX 136 CLHY 586 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE | | IF 48 HOUR SCRUB OR LONGER, | PERFORM NEXT TWO STEPS AT | BKUP CONSOLE. | | 15-0293 CGLS $PRINT V0 CF DPSMON | PERFORM PGM | $PRINT V0 CF DPSRTN | PERFORM PGM | | VERIFY CORRECT LOAD CONTENTS | | NOT PERFORMED ______| | NOTE | | PERFORM NEXT STEP IF CMD | FILE IS PRESENT BUT CONTENTS | ARE CORRUPTED. | | 15-0294 CGLS $DELENT V0 CF DPSMON | PERFORM PGM | $DELENT V0 CF DPSRTN | PERFORM PGM | | NOT PERFORMED ______| | 15-0295 CGLS $LIBRARY V0 VT | PERFORM PGM | VERIFY CF DIRECTORY EXIST | | NOTE | | DO NOT PERFORM NEXT FOUR | STEPS IF 48 HR SCRUB OR | LONGER AND CORRECT LOAD | CONTENTS WERE VERIFIED. | | 15-0296 CGLS LPS REQUEST KEYBOARD UTILITIES AT 127 BKUP CONSOLE. | NOT PERFORMED ______| 15-0297 CGLS VERIFY 1 APPL CONC AVAILABLE $BLDLIB VO CF #900 8 4 0 | PERFORM PGM | NOT PERFORMED ______| | 587 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0298 CGLS CRT 2 POSITION: | | SIGN ON TO SDC (SDC3) | SIGNON - PRESS | LOGIN: USERID - SDC XMIT | PASSWORD: PASSWORD - SDC XMIT | VERIFY: P1AP01 | RSHELL> | | CD/APPS/DAPFILE/FRAS_GLS/CMDFILES | SDC XMIT | LS - SDC XMIT | SHIFT CLEAR - SCD XMIT (CLEAR PAGE) | SDC XMIT - PRESS | SDC XMIT - PRESS | CAT DPSMON - SDC XMIT | HARD COPY - PRESS | | CRT 1 POSITION: | | $T | PERFORM PGM | CRT 2 - XMIT RESP | VERIFY CORRECT DATA COPIED | PAG - XMIT RESP | SAV VO CF DPSMON - XMIT RESP | | 588 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0298 CRT 2 POSITION: | CON'T | SHIFT CLEAR - SDC XMIT (CLEAR PAGE) | SDC XMIT - PRESS | SDC XMIT - PRESS | CAT DPSRTN - SDC XMIT | HARD COPY - PRESS | | CRT 1 POSITION: | | CRT 2 - XMIT RESP | VERIFY CORRECT DATA COPIED | PAG - XMIT RESP | SAV VO CF DPSRTN - XMIT RESP | EXI - XMIT RESP | | $PRINT VO CF DPSMON | PERF PGM | $PRINT VO CF DPSRTN | PERF PGM | | PRINTER: VERIFY CORRECT LOAD | CONTENTS | | CRT 2 POSITION | | EXIT - SDC XMIT | CPU ENABLE - PRESS | | 15-0299 CGLS LPS INHIBIT KEYBOARD UTILITIES AT BKUP 127 CONSOLE. | NOT PERFORMED ______| 15-0300 CGLS OTC C12 RECOVERY PROCEDURE COMPLETE. 132 589 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- C&T LAB RSS ANTENNA PATCH ------------------------- VERIFICATION ------------ 15-0301 OTC RSRT PERFORM FUNCTIONAL RF TEST OF SU72634 132 RSS RACK 8234 TO SUPPORT RANGE SAFETY OPEN LOOP CHECKOUT. REPORT COMPLETION. 1. RACK 8234 PANEL A7 PATCH/VERIFY THE FOLLOWING: J 2 - J18 J 3 - J19 J 4 - J20 J 6 - J22 J 7 - J23 J 8 - J24 J10 - J26 J11 - J27 J12 - J28 J15 - J31 J16 - J32 50 OHM LOAD J1 AND J17 2. RACK 8234 PANEL A2 (CIRCUIT BREAKERS) CB 1 & 2 - ON 3. RACK 8234 PANEL A1 (AUDIO PANEL) POWER 1 & 2 - ON LINE SELECTOR 1 & 2 - POSITION 1 VOLUME 1 & 2 - 9 O'CLOCK (AS REQUIRED) 4. RACK 8234 PANEL A2 & A3 (VCR RECORDERS) POWER - ON RECORD LEVEL - POSITION 5 (DETENT) SP/EP - EP CH/AUX - AU T120 OR GREATER BLANK TAPE - INSERT 590 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0301 5. RACK 8234 PANEL A8 & A10 CON'T (IRD PANELS) IRD PWR - ON 6. RF SIGNAL GENERATOR SETUP (EXTERNAL TEST EQUIPMENT) FREQUENCY - 416.5 MHZ MODULATION - NONE OUTPUT LEVEL - (-70 DBM) CAL NO.__________ 7. RACK 8229 PANEL A7 REMOVE/VERIFY U-LINE J14 TO J15 PATCH. 8. CONNECT RF OUTPUT OF SIGNAL GENERATOR TO 8229A7J15 9. RACK 8230 PANEL A10 (A11) SWITCH S2 - TRANSMIT SWITCH S3 - OFF 10. RACK 8234 RECORD AGC METER READINGS PANEL A8 IRD AGC __________V (GREATER THAN 2V) PANEL A10 IRD AGC __________V (GREATER THAN 2V) 11. RACK 8229 PANEL A7 DISCONNECT RF OUTPUT OF SIGNAL GENERATOR FROM 8229A7J15. 12. PATCH U-LINE BETWEEN J14 AND J15 13. PANEL A5 (STRIP CHART RECORDER) VERIFY PAPER SUPPLIES AND RECORDER OPERATES. SET CLOCK TO IRIG EXT. T:______ 591 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RCS MANIFOLD 5 ISOLATION VALVE CLOSURE -------------------------------------- 15-0302 OTC COFC PERFORM RCS MANIFOLD 5 ISOLATION VALVE 132 CLOSURE. REPORT COMPLETE. NOTE FOLLOWING SWITCHES CONFIGURED TO SUPPORT RCS VERNIER SINGLE COMMAND TEST. 15-0303 -07H30M COFC ASP PNL R15 (R14) MANIFOLD ISOLATION ROW C MN C L5 CB - CLOSE R5 CB - CLOSE F5 CB - CLOSE PNL 07 AFT LEFT RCS MANIFOLD ISOLATION 5 SW - CLOSE (HOLD) 5 TB CL 5 SW - GPC (RELEASE) AFT RIGHT RCS MANIFOLD ISOLATION 5 SW - CLOSE (HOLD) 5 TB CL 5 SW - GPC (RELEASE) PNL 08 FWD RCS MANIFOLD ISOLATION 5 SW - CLOSE (HOLD) 5 TB CL 5 SW - GPC (RELEASE) OMRS V79GEN.300 592 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0304 COFC CONSOLE KYBD DMON FD XMIT CMD KEY - PRESS CRT (DMON PG) VERIFY FD ON WHERE: FD -- V42X1233X1 FWD RCS MANF 5 OX ISO VLV CL V42X1333X1 FWD RCS MANF 5 FU ISO VLV CL V42X2235X1 L AFT RCS MANF 5 OX ISO VLV CL V42X2335X1 L AFT RCS MANF 5 FU ISO VLV CL V42X3235X1 R AFT RCS MANF 5 OX ISO VLV CL V42X3335X1 R AFT RCS MANF 5 FU ISO VLV CL OMRS V79GEN.300 DEU 3 TO CONSOLE C11 -------------------- NOTE DEU IS REQUIRED FOR THE RCS SINGLE COMMAND TESTS AND THE OMS GIMBAL PROFILE. 15-0305 COFC OTC CHANGE RESPONSIBLE CONSOLE FOR 132 DEU 3 TO CONSOLE C11. OTC CDPS 15-0306 CDPS CONSOLE KYBD HOME CMD KEY - PRESS ISSU N72IV102D #B00B XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS HOME CMD KEY - PRESS C CO _DEU3G LDBA C11 XMIT CMD KEY - PRESS 15-0307 CDPS OTC RESPONSIBLE CONSOLE FOR 132 DEU NO. 3 NOW ASSIGNED TO C11. OTC COFC 593 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RCS VERNIER SINGLE CMD TEST PREPS --------------------------------- 15-0308 COFC CURSOR CNTL (SAB19/SWB01) RCS - OPS MANAGER XMIT CURSOR KEY - PRESS 15-0309 COFC CURSOR CNTL (VABM6/VWB29) SINGLE COMMAND TEST XMIT CURSOR KEY - PRESS 15-0310 COFC APPL PG (VABM6/VSB53) PFK 3 - PRESS (DEU NUMBER) RCS VERNIER SINGLE CMD TEST --------------------------- NOTE A MINIMUM OF 25 FT CLEAR OF PERSONNEL AROUND THE FWD, LEFT AND RIGHT PODS IS REQUIRED FOR THE VERNIER SINGLE CMD TEST. TEST DURATION IS APPROX 50 SEC. 15-0311 COFC OTC READY FOR RCS VERNIER SINGLE SU72627 132 COMMAND TEST. OTC NTD 232 15-0312 NTD *SCC VERIFY ALL PERSONNEL CLEAR FROM SU72684 232 25 FT RADIUS AROUND FWD, LEFT AND *SCC *PSE RIGHT POD VERNIER THRUSTERS FOR NET RCS SINGLE COMMAND TEST. VERIFY 105 SAFETY CONCURRENCE TO PROCEED. 15-0313 *PSE *SCC ALL PERSONNEL CLEARED. YOU HAVE NET SAFETY CONCURRENCE TO PROCEED WITH 105 RCS VERNIER SINGLE COMMAND TEST. *SCC NTD 232 NTD OTC OTC COFC 132 OMRS V79GEN.300 594 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0314 COFC CURSOR CNTL (VABM6/VSB53) ALL VERNIER THRUSTERS XMIT CURSOR KEY - PRESS 15-0315 COFC CURSOR CNTL (VABM6/VSB53) END SELECTIONS/PERF PGM XMIT CURSOR KEY - PRESS 15-0316 COFC APPL PG (VABM6/VSB53) PFK1 KEY - PRESS (CONTINUE - 25 FT CLEAR ESTABLISHED) 15-0317 COFC RCS VERNIER SINGLE CMD TEST COMPLETE WITHOUT ANOMALY. OMRSD V79AS0.012-1 (VSB53) (F5L/F5R) OMRSD V79AS0.013-1 (VSB53) (F5L/F5R) OMRSD V79AS0.062-1 (VSB53) (L5D/L5R) OMRSD V79AS0.063-1 (VSB53) (L5D/L5R) OMRSD V79AS0.110-1 (VSB53) (R5R/R5D) 15-0318 COFC OTC RCS VERNIER SINGLE CMD TEST 132 COMPLETE. 15-0319 OTC NTD RCS VERNIER SINGLE CMD TEST 232 COMPLETE. SAFETY CLEARS NO NTD *SCC LONGER REQUIRED. *SCC *PSE NET 105 15-0320 COFC APPL PG (VABM6/VSB53) PFK15 KEY - PRESS (TERM VSB53) 15-0321 COFC APPL PG (VABM6/VWB29) PFK15 KEY - PRESS (TERM VABM6) 595 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RCS MANF 5 ISOLATION VALVE RECONFIGURE -------------------------------------- NOTE THE FOLLOWING SWITCHES ARE RECONFIGURED OPEN FOR LAUNCH AFTER THE RCS VERNIER SINGLE CMD TEST. 15-0322 COFC ASP PNL 07 AFT LEFT RCS MANIFOLD ISOLATION 5 SW - OPEN 5 TB OP 5 SW - GPC (RELEASE) AFT RIGHT RCS MANIFOLD ISOLATION 5 SW - OPEN 5 TB OP 5 SW - GPC (RELEASE) PNL 08 FWD RCS MANIFOLD ISOLATION 5 SW - OPEN 5 TB OP 5 SW - GPC (RELEASE) 596 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OMS GIMBAL PROFILE ------------------ NOTE OMS GIMBAL PROFILE IS ONLY REQUIRED ONE TIME PRIOR TO LAUNCH MAKING THE REPEAT OF THE TEST OPTIONAL FOR A RECYCLE LAUNCH COUNTDOWN. DO NOT PERFORM THIS TEST IF IT HAS BEEN PERFORMED IN THE PREVIOUS COUNTDOWN UNLESS THERE IS CONCERN OVER ACTIVITY IN THE GENERAL LRU AREA OR CONCERN OVER POSSIBLE TREND DATA OR CONCERN OVER THE TIME ELAPSED SINCE THE LAST TEST. IN ORDER TO AVOID ANY POSSIBLE CONFLICT BETWEEN ONBOARD IMU OPERATIONS AND ONBOARD ECP EXECUTION, DO NOT PERFORM OMS GIMBAL PROFILE DURING IMU ATT DET, PREFLIGHT CAL OR ALIGNMENTS. OMS GIMBAL TEST GENERATES ECP'S WHICH HAVE A HIGHER PRIORITY THAN IMU OPERATIONS IN THE GPCS. TO ENSURE ALL PERSONNEL AND EQUIPMENT ARE OUT OF THE NOZZLE ENVELOPE, THE ESP'S SHOULD BE LOWERED PRIOR TO OMS GIMBALLING. 15-0323 -07H30M COFC OTC SET PP 1 UNIT 6 ON LINE FOR SU72625 132 COFC PER OMI S9002VL16. OTC NTD REPORT COMPLETION. 232 NTD LPS LPS C2MC 127 NOT PERFORMED ______ 597 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0324 COFC OTC OMS GIMBAL PROFILE WILL BEGIN IN 132 ___ MINUTES. VERIFY MCC READY OTC NTD FOR OMS GIMBAL PROFILE. 232 NTD *FLT NOT PERFORMED ______ 15-0325 *FLT NTD MCC READY FOR OMS GIMBAL PROFILE. 232 NTD OTC NOT PERFORMED ______ 15-0326 OTC COFC PERFORM OMS GIMBAL PROFILE SU72625 132 PER S0007VL4 (SEQ 43). (30 MIN) SU72679 NOT PERFORMED ______ 598 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OPEN ORBITER LEEWARD VENT DOORS ------------------------------- 1 AND 2 (CONTINGENCY) --------------------- NOTE IF O2 CONCENTRATION IN OAA WHITE ROOM BECOMES LESS THAN 20 PCT AS INDICATED ON W/R O2 METER (OTV CAM 005/105), PERFORM NEXT THREE STEPS TO OPEN LEEWARD VENT DOORS 1&2. 15-0327 -07H15M NTD OTC O2 CONCENTRATION WITHIN WHITE SU72539 232 ROOM LESS THAN 20 PCT, OPEN OTC CPVD ORBITER VENT DOORS 1 AND 2 ON 132 LEEWARD SIDE. NOT PERFORMED ______ 15-0328 CPVD CURSOR CNTL (VAM31A/VAM09A) VENT DOORS 1&2 (LEEWARD) OPEN TARGET XMIT CURSOR NOT PERFORMED ______ 15-0329 CPVD OTC LEEWARD VENT DOOR OPENING COMPLETE. 132 OTC NTD 232 NOT PERFORMED ______ 599 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF O2 CONCENTRATION IN WHITE ROOM STILL LESS THAN 20 PCT AFTER PVD OPENED LEEWARD VENT DOORS. 15-0330 OTC *FCM WHITE ROOM 132 1. EXHAUST FAN SW - ON 2. POSITION REAR SWINGING DOORS IN OPEN POSITION AND SECURE. NOT PERFORMED ______ NOTE IF PREVIOUS FOUR STEPS DO NOT SOLVE LESS THAN 20 PCT O2 CONCENTRATION PROBLEM, PERFORM NEXT FOUR STEPS TO OPEN WINDWARD VENT DOORS 1 AND 2 ONLY IF WIND CONDITION IS LESS THAN 18 KTS AND NO RAIN EXPECTED. REF OMRS V05AG0.060 15-0331 NTD *FLT WINDWARD VENT DOORS 1 AND 2 232 WILL BE OPENED. NOT PERFORMED ______ 15-0332 NTD OTC OPEN WINDWARD VENT DOORS 1 AND 2. 232 OTC CPVD 132 NOT PERFORMED ______ 600 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0333 CPVD CURSOR CNTL (VAM31A/VAM09A) VENT DOORS 1 AND 2 (WINDWARD) OPEN TARGET XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 15-0334 CPVD OTC WINDWARD VENT DOOR OPENING 132 COMPLETE. OTC NTD 232 NTD *SCC NOT PERFORMED ______ DPS LCC MONITOR ACTIVATION/LDB ------------------------------ REDUNDANCY CHECK ---------------- NOTE LDB SWITCHING WILL OCCUR IN NEXT STEP. 15-0335 -07H15M OTC CDPS ACTIVATE DPS LCC MONITOR AND SU72617 132 PERFORM LDB REDUNDANCY CHECK PER S0007VL4 (SEQ 49, ITEM 14). (5 MIN) REPORT COMPLETION. OMRSD S00FB0.230-1R 601 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAYLOAD COMM CHECKS | ------------------- | | 15-0336 -07H15M NTD PTC PERFORM A/G-1 COMM CHECKS WITH | 232 PAYLOAD LAUNCH TEAM ON OIS | PTC ICTC CH 212. (STS-93) | ICC1 | AXTC | | OMS GIMBAL PROFILE COMPLETE --------------------------- NOTE PERFORM NEXT TWO STEPS IF THE REFERENCED TEST WAS PERFORMED ON THIS RUN. 15-0337 -07H00M COFC OTC OMS GIMBAL PROFILE COMPLETE. NOT PERFORMED ______ 15-0338 COFC OTC SET PP 1 UNIT 6 OFF LINE. 132 REMOVE DATA FOR DATA COORDINATOR. OTC NTD 232 NTD LPS LPS C2MC 127 NOT PERFORMED ______ DEU 3 RETURN TO C12 ------------------- 15-0339 COFC CONSOLE KYBD ISSU N72IV102D 0 XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS C CO _DEU3G LDBA C12 XMIT CMD KEY - PRESS 15-0340 COFC OTC RESPONSIBLE CONSOLE FOR DEU 3 132 CDPS IS NOW C12. 602 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE OMS TVC LCC MONITORING ------------------------------- 15-0341 COFC APPL PG A (SAB20/SWB02) PFK13 KEY - PRESS (ACT EMON SETUP) 15-0342 COFC CURSOR CNTL (SAB20/SWB02 PG A) A-OMS TVC XMIT CURSOR KEY - PRESS OMRSD V79AZ0.090-1 (SWB02) | 15-0343 COFC APPL PG A (SAB20/SWB02) PFK13 KEY - PRESS (DE-ACT EMON SETUP) 603 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RED CREW ASSEMBLED ------------------ 15-0344 -07H00M NTD OTC VERIFY RED CREW ASSEMBLED AND SU72633 232 READY TO SUPPORT. OTC *PAD 132 15-0345 -06H00M STM JBDY VERIFY PROTECTIVE CLOTHING 111 MOBILE VAN PARKED AT COMPLEX J. JBDY (7-6428) 15-0346 STM JYVO CONTROL OF VIDEO SWITCHER 457 COMM 138 DURING CONTINGENCIES WILL BE AT DIRECTION OF NVM/*PAD UNTIL PAD REENTRY. EGRESS OPERATIONAL CHECKS ------------------------- NOTE NOTED REQUIREMENT SATISFIED BY THE FOLLOWING EIGHT STEPS. OMRS S00FA0.820 15-0347 -07H00M NTD OTC EMERGENCY EGRESS SYSTEM (SAW01/HWW16) 232 VERIFY EGR HFDS OPERATIONAL CHECKS FOR OTC CHGD PRIMARY AND SECONDARY HIMS: 132 ALRM = OFF CONF = ON SELF = OFF VERIFY EGR EETD OPERATIONAL CHECKS FOR PRIMARY AND SECONDARY HIMS: AMBIENT +/- 15 DEGREES FARENHEIT 15-0348 CHGD WHITE ROOM ARRAY - VERIFY 2 OF 3 OPERATIONAL: EGR FD1 EGR TD1 EGR TD2 604 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0349 CHGD OAA ARRAY - VERIFY 2 OF 4 OPERATIONAL: EGR FD2 EGR FD3 EGR TD3 EGR TD7 15-0350 CHGD FSS ARRAY - VERIFY 3 OF 5 OPERATIONAL: EGR FD7 EGR FD11 EGR FD12 EGR FD13 EGR FD14 15-0351 CHGD 175 FOOT LEVEL ARRAY - VERIFY 4 OF 6 OPERATIONAL: EGR FD8 EGR FD9 EGR FD10 EGR TD8 EGR TD9 EGR TD10 15-0352 CHGD 195 FOOT LEVEL ARRAY - VERIFY 4 OF 6 OPERATIONAL: EGR FD4 EGR FD5 EGR FD6 EGR TD4 EGR TD5 EGR TD6 605 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0353 CHGD OTC EMERGENCY EGRESS OPERATIONAL CHECKS COMPLETE. NO ANOMALIES NOTICED. 15-0354 NOTED REQUIREMENT COMPLETE. OMRSD S00FA0.820 COMM CMD TO LAUNCH CONFIG COMPLETE ---------------------------------- 15-0355 -07H00M CCSE OTC COMM CMD TO LAUNCH CONFIG-MCCH SU72568 132 COMPLETE (V1117). OTC NTD 232 OMRSD S00FA0.372-A OMRSD S00FA0.372-D OMRSD S00FA0.372-H OMRSD S00FA0.372-I OMRSD S00FB0.281-A-1R OMRSD S00FB0.281-B-1R OMRSD S00FB0.281-C-1R OMRSD S00FB0.281-D-1R 606 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP AFTER COMPLETION OF COMM CMD TO LAUNCH CONFIG AND SWITCHLIST. 15-0356 -07H00M OTC CCSE CRT (VAA19) 132 VERIFY: PM CONTROL CMD ANTENNA SW 2 ON PM QUAD SEL ULA SWITCH SCAN GPC FM HEMI SEL UPPER SWITCH SCAN GPC XPNDR-2 ON MODE STDN LOW FREQ _____ (HIGH OR LOW) __________ LOOP STRESS (RECORD) __________ AGC (RECORD) __________ WATTS (RECORD) NSP 2 ON BIT SYNC LOCKED FRM SYNC LOCKED BITE GO PRE AMP OFF PRE AMP HTRS ON PWR AMP OFF STANDBY -1 OFF, -2 OFF CRT (VWA40) VERIFY COMSEC ENCRYPT RCV COMSEC FRAME SYNC LOCKED 607 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MCCH ABORT ADVISORY CHECK ------------------------- NOTE DO NOT PERFORM ABORT ADVISORY CHECK WHILE COMM COMMAND TO LAUNCH CONFIG IS IN PROGRESS. 15-0357 -07H00M NTD OTC STANDBY FOR ABORT ADVISORY SU72618 232 CHECKS ON OIS CH 212. OTC ASP 132 CISL 15-0358 NTD *FLT VERIFY SYSTEM ARMED AND READY TO 232 PERFORM CHECK ON OIS CH 212. 15-0359 -07H00M NTD *FLT PERFORM FLT ABORT ADVISORY CHECKS 232 NOTE NEXT 12 STEPS VERIFY THE MCC FLIGHT DIRECTOR CONSOLE. ASP SHOULD REPORT ABORT LIGHT ON OR OFF REGARDLESS OF LIGHT INTENSITY. 15-0360 *FLT TRANSMIT DSM 4054 (ABORT A/B ON) VIA FD CONSOLE HARDWARE PBI 15-0361 ASP PANEL F6 ABORT INDICATOR LIGHT ON 15-0362 *FLT TRANSMIT DSM 4053 (ABORT B OFF) 15-0363 ASP PANEL F6 ABORT INDICATOR LIGHT ON 15-0364 *FLT TRANSMIT DSM 4051 (ABORT A OFF) 15-0365 ASP PANEL F6 ABORT INDICATOR LIGHT OFF 608 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0366 *FLT TRANSMIT DSM 4054 (ABORT A/B ON) VIA FD CONSOLE SOFTWARE PBI 15-0367 ASP PANEL F6 ABORT INDICATOR LIGHT ON 15-0368 *FLT TRANSMIT DSM 4051 (ABORT A OFF) 15-0369 ASP PANEL F6 ABORT INDICATOR LIGHT ON 15-0370 *FLT TRANSMIT DSM 4053 (ABORT B OFF) 15-0371 ASP PANEL F6 ABORT INDICATOR LIGHT OFF NOTE NEXT FOUR STEPS VERIFY THE MCC FLIGHT DYNAMICS OFFICER CONSOLE. ASP SHOULD REPORT ABORT LIGHT ON OR OFF REGARDLESS OF LIGHT INTENSITY. 15-0372 *FLT TRANSMIT DSM 4054 (ABORT A/B ON) VIA FDO CONSOLE HARDWARE PBI 15-0373 ASP PANEL F6 ABORT INDICATOR LIGHT ON 15-0374 *FLT TRANSMIT BOTH DSM 4051 (ABORT A OFF) AND DSM 4053 (ABORT B OFF) 15-0375 ASP PANEL F6 ABORT INDICATOR LIGHT OFF 15-0376 *FLT NTD ABORT ADVISORY CHECKS COMPLETE. SU72618 232 609 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0377 -07H00M STM JSTC DELIVER 40 ELSA'S AND 16 30 MIN LS 111 AIR PACKS (LOCATED IN AIR PACK SU72668 JSTC *SCB VAN) TO COMPLEX J. (30 MIN) NET 104 TOP-OFF SS SYS -------------- 15-0378 STM JBWC TOP OFF ELEVATED SOUND WSSA 111 SUPPRESSION WATER TANK PER SU72671 OMI M3189.001. GOX HOOD PURGE TO OPERATING --------------------------- PARAMETERS ---------- 15-0379 -07H00M TBC CMEC PERFORM GOX VENT HOOD PURGE FLOW SU72655 136 AND TEMPERATURE RETURN TO OPERATING PARAMETERS PER OMI G2158. 610 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FINAL LH2 PREPS COMPLETE ------------------------ NOTE DO NOT PERFORM NEXT STEP IF SUPPORTING SCRUB/TURNAROUND. 15-0380 -07H00M CLHY TBC G3251 OPERATION SUPPORT SETUP SU72651 136 14 - LH2 FINAL PREPS FOR LOADING TBC NTD COMPLETE. PERSONNEL CLEARING TO 232 FALLBACK AREA. LH2 STORAGE AREA NTD *SCC PERIMETER ROAD BARRIERS REMOVED AND WARNING LIGHTS CONFIGURED TO FLASHING RED. NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF SUPPORTING SCRUB/TURNAROUND. 15-0381 -07H00M CLHY TBC LH2 FINAL PREPS FOR VEHICLE LOADING 136 PER G3255 COMPLETE. PERSONNEL CLEARING TBC NTD TO FALLBACK AREA. LH2 STORAGE ROAD 232 BARRIERS REMOVED AND WARNING LIGHTS NTD *SCC CONFIGURED TO FLASHING RED. NOT PERFORMED ______ 15-0382 NTD STM LH2 STORAGE AREA FIRE TRUCK FIRE 232 RELEASED FALLBACK TO PAD ___ STM JSTC GATE. 111 JSTC JFIR 114 611 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 PRE-CHILLDOWN OPS (S1004) ----------------------------- 15-0383 TBC CLHY PERFORM LH2 PRE-CHILLDOWN SU72654 136 OPERATIONS PER OMI S1004. 15-0384 TBC OTC CMPS SUPPORT REQUIRED FOR LH2 132 PRE-CHILLDOWN OPERATIONS ON OTC CMPS OIS CH 166. CONFIGURE ICE/FROST MONITORING AREA ----------------------------------- 15-0385 -06H45M TBC NTD SUPPORT PRE-OPERATION SETUPS COMM 232 PER S6444 ON CHANNELS 222, SU72656 NTD STM 223,224,225. CTIF WILL CONTACT SU72672 STM JYVO JYVO WHEN READY FOR CAMERA 138 MOVEMENT. JYVO JTV1 JTV2 15-0386 TBC CTIF SET INITIAL CONFIGURATION FOR ICE/ 136 FROST MONITORING AND DEBRIS EVALUATION PER OMI S6444. 15-0387 TBC CTIF VERIFY PMBT WITHIN RANGE SPECIFIED 136 PER S6444. 15-0388 CTIF TBC SRM PMBT WITHIN SPECIFIED RANGE 136 PER S6444. OMRSD S00FA0.600-1 TOP-OFF SS SYS COMPLETE ----------------------- 15-0389 JBWC STM SS ELEVATED TANK TOP-OFF WSSA 111 COMPLETE. SU72671 612 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IMU OPERATE ----------- NOTE SPEC 104 IS REQUIRED ON CRT 2 FOR IMU OPERATIONS AND WILL BE CALLED BY LPS. IMU(S) TO OPERATE SHALL OCCUR NO LATER THAN L-08H20M. DURING IMU ATT DET, DO NOT PERFORM DDU CHECKOUT, TCS-S OR ECP'S. 15-0390 OTC CDPS CHANGE RESPONSIBLE CONSOLE FOR 132 DEU 2 TO C11 15-0391 CDPS CONSOLE KYBD HOME CMD KEY - PRESS ISSU N72IV101D #B00B XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS HOME CMD KEY - PRESS C CO _DEU2G LDBA C11 XMIT CMD KEY - PRESS 15-0392 CDPS OTC RESPONSIBLE CONSOLE FOR DEU2 NOW C11. 132 15-0393 -06H45M OTC CGNC PERFORM IMU OPERATE AND ATTITUDE SU72620 132 DETERMINATION PER OMI V1123. (24 MIN) RT OMI LOG NO.__________ APU HEATER ACTIVATION --------------------- 15-0394 -06H45M OTC CAPU PERFORM APU HEATER ACTIVATION SU72621 132 PER S0007VL4 (SEQ 42). (30 MIN) 15-0395 OTC CAPU PERFORM APU SW SCAN PER S0007VL4 132 (SEQ 42). (30 MIN) 613 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET/IT GN2 PURGE INITIATED ------------------------- 15-0396 -06H45M CLHY TBC ET/IT GN2 PURGE HAS BEEN SU72657 136 INITIATED. TBC CLOX CHGD __________GMT 232 NTD ET/IT PURGE STATUS ------------------ NOTE NEXT STEP NORMALLY PERFORMED 30 MINUTES AFTER ET/IT PURGE HAS BEEN INITIATED BUT MAY OCCUR EARLIER. 15-0397 CLHY TBC VERIFY O2 CONCENTRATION IN ET/IT 136 LESS THAN 10,000 PPM O2 AND TBC CHGD DECREASING. 15-0398 CHGD JHGD LCC 3R18 HUMS CONTROL ROOM - HUMS 177 REMOTE TERMINAL 1. "VEHICLE PAGE" - SELECT 2. SOURCES -SELECT "LINES 1-8" 3. LINE - SELECT "S/L 1" 15-0399 CHGD TBC O2 CONCENTRATION IN ET/IT LESS THAN 136 10,000 PPM AND DECREASING. TBC CLHY CLOX __________GMT 614 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 AND LO2 TSM GN2 PURGES INITIATED ------------------------------------ 15-0400 CLHY TBC LH2 AND LO2 TSM GN2 PURGES HAVE SU72658 136 BEEN INITIATED. TBC CHGD _________ GMT LH2 TSM GN2 PURGE STATUS ------------------------ 15-0401 CLHY TBC VERIFY O2 CONCENTRATION IN MLP LH2 136 TSM DECREASING. TBC CHGD 15-0402 CHGD JHGD LCC 3R18 HUMS CONTROL ROOM - HUMS | 177 REMOTE TERMINAL | 1. "VEHICLE PAGE" - SELECT 2. SOURCES - SELECT "LINES 9-16" | 3. LINE - SELECT "S/L 9" | 15-0403 CHGD TBC O2 CONCENTRATION IN MLP LH2 TSM 136 DECREASING. _________GMT GOX HOOD PURGE TO OPERATING --------------------------- PARAMETERS COMPLETE ------------------- 15-0404 -06H40M CMEC TBC GOX VENT HOOD PURGE FLOW SU72655 136 RETURNED TO OPERATING PARAMETERS PER OMI G2158. 615 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0405 -06H40M TBC CMEC TERMINATE GAG02 PROGRAM AND 136 TRANSFER GOX VENT ARM SYSTEM MONITORING AND CONTROL TO VAJ14 PROGRAM PER OMI G2158. 15-0406 -06H40M CMEC TBC GAG02 PROGRAM TERMINATED AND GOX 136 VENT SYSTEM MONITORING AND CONTROL TRANSFERED TO VAJ14 PER G2158. OMRSD S00FC0.090-1 FINAL OPS/SAFETY WALKDOWN COMPLETE ---------------------------------- 15-0407 -06H30M NPM NTD BDA CLEAR FINAL OPS/SAFETY NET WALKDOWN COMPLETE. DISCREPANCIES 110 IDENTIFIED: NTD *SCC 232 __________________________________ __________________________________ __________________________________ NPM WILL DOCUMENT ALL DISCREPANCIES IN APPENDIX M (S0007VL4). NOTE APPLICABLE DISCREPANCIES ARE TO BE DELIVERED TO FR NTD FOR ASSESSMENT BY SSV (SPE) AND/OR SUPPORT (STM/CCC) REPRESENTATIVES. 15-0408 NTD STM BDA CLEAR FINAL OPS/SAFETY WALKDOWN 232 SPE COMPLETE. DISPOSITION OF FOD MUST STM PSTM BE COMPLETED BY START OF T-3HR HOLD. NET 104 616 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SAFETY SIGN REMOVAL STATUS -------------------------- 15-0409 *PSE *SCC ALL SFOC SAFETY WARNING SIGNS HAVE NET BEEN REMOVED WITH FOLLOWING 105 EXCEPTIONS: *SCC NTD 232 1. PTCR - SOUTH TUNNEL ENTRANCE NTD OTC TBC 2. ECS DOORS (TWO) STM PTC 3. PTCR DOOR (GROUND LEVEL) 4. PAD CATACOMB DOORS 5. PAD TUNNEL - EAST AND WEST ENTRANCES INCREASE AFT FLOW (V1122) ------------------------- CAUTION TO PREVENT POSSIBLE OVER PRESSURIZATION OF AFT COMPARTMENT, AIR TO GN2 CHANGEOVER MUST BE PERFORMED PRIOR TO NEXT STEP. 15-0410 -06H30M OTC CPVD 1. VERIFY ECS GN2 PURGE TO SU72622 132 ORBITER HAS STABILIZED. 2. INCREASE CRYO LOAD AFT FLOW RATE TO 110 +/- 5 LB/MIN AND RAISE AFT INTERFACE TEMP TO 105 +5/-10 DEG F PER OMI V1122. 617 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP FOR PAD A LAUNCH ONLY. 15-0411 NTD STM UNLOCK AND OPEN PERIMETER SEC 232 GATE TO HELIPAD NO. 8. VERIFY STM JSTC WHEN COMPLETE. 111 JSTC *SEC 114 NOT PERFORMED ______ 15-0412 STM GYCC PERFORM PRE-OPERATIONS SETUP COMM 111 JSTC INSTRUCTIONS FOR A5204 CREW JSTC JBDY TRANSFER - CREW SUITING ROOM SU72670 JSTC KSTC O&C TO PAD ___. 114 15-0413 *SCB JSTC 12 LAPS WITH COMM DELIVERED TO LS NET FIRE STATION NO. 2. 104 JSTC STM 111 15-0414 -06H30M *SCB JSTC AIR PACK VAN DEPARTING PAD LS NET GATE ENROUTE TO COMPLEX J. 104 618 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LOX FINAL PREPS COMPLETE ------------------------ 15-0415 PLOX CLOX LOX STORAGE AREA FINAL PREPS COMPLETE. 156 ROAD BARRIERS REMOVED AND WARNING CLOX TBC LIGHTS ARE FLASHING RED. 136 TBC NTD 232 NTD *SCC 15-0416 -06H30M CLOX TBC PERFORM FOLLOWING: SU72647 136 TBC NTD 1. LOX SYSTEM FINAL PREPS FOR 232 VEHICLE LOADING PER G3151 (OR G3155 IF PERFORMING SCRUB TURNAROUND) COMPLETE. 2. READY TO INITIATE MPS AND LOX LOADING PRELIMINARIES AND SSME PURGES PER OMI S1003. 15-0417 -06H30M CLOX COMPLETION OF G3151/G3155 SEQUENCES IN PREVIOUS STEP SATISFIES NOTED OMRS REQUIREMENTS. OMRSD S00FA0.116-1 OMRSD S00FA0.120-1 OMRSD S00FA0.141-1 OMRSD S00FB0.330-1 OMRSD S00L00.051-B-1 15-0418 NTD STM LOX STORAGE AREA FIRE TRUCK FIRE 232 RELEASED TO FIRE STATION NO. 2. STM JSTC 111 JSTC JFIR 114 619 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LOX LOADING PRELIMINARIES ------------------------- 15-0419 -06H30M NTD TBC PERFORM LOX AND MPS LOADING SU72648 232 PRELIMINARIES PER OMI S1003. TBC CLOX 136 CLOX CMPL 156 NOTE NOTED OMRS REQUIREMENTS ARE SATISFIED BY COMPLETION OF ET LOX TANKING FROM LOX/ MPS LOADING PRELIMINARIES THROUGH T-10 SECONDS. DETAILS OF LOX TANKING ARE SPECIFIED IN S1003. OMRS S00FB0.090-A-1 OMRS S00FB0.300-1 OMRS S00FB0.310-1 OMRS S00FB0.320-1 OMRS S00FB0.340-1 OMRS S00FC0.080-1 OMRS S00FC0.100-1 OMRS S00FC0.120-1 OMRS S00FD0.062-1 OMRS S00FD0.073-1 OMRS S00FD0.094-1 OMRS S00FD0.095-1 OMRS S00FD0.121-A-1R OMRS S00FF0.101-1 OMRS S00FF0.145-1 OMRS S00FM0.043-1 OMRS S00FM0.050-1 OMRS S00FM0.060-1 OMRS S00FM0.321-1 OMRS S00FM0.330 OMRS S00FM0.342-1 OMRS S00FM0.440-1 15-0420 -06H30M TBC OTC CMPL SUPPORT REQUIRED FOR MPS LOX 132 LOADING PRELIMINARIES ON CH 156. OTC CMPL 620 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0421 CLOX TBC VERIFY GOX VENT ARM SYSTEM 136 READY TO SUPPORT LOX LOADING. TBC CMEC REPORT ANY OUT OF TOLERANCE OR ABNORMAL CONDITION TO CLOX. JBFX TO 136/JCFM TO 158 MONITOR ------------------------------- 15-0422 -06H30M NTD JBFX REMAIN ACTIVE ON OIS CHANNEL 232 WSSA 232 AND MONITOR CH 136 FROM NOW THRU T-20 MIN. PERFORM COMM CHECK WITH CLOX, CLHY AND TBC ON CH 136. FLOW FIREX WATER IF DIRECTED BY CLOX OR CLHY. REPORT YOUR ACTION ON OIS CH 136 THEN TO NTD ON 232. 15-0423 TBC JBFX PERFORM COMM CHECK ON CH 136. WSSA 136 CLOX JBFX RETURN TO CH 232 ACTIVE AND CLHY CH 136 MONITOR THRU T-20 MIN. 15-0424 CLOX TBC JCFM REQUESTED ON OIS CH 158 TO: 136 TBC NTD 1. SUPPORT CLOX WITH LOX PUMP 232 INSTRUMENTATION RECORDING NTD STM REQUESTS. (S1003) STM JCFM 111 2. PERFORM COMM CHECK WITH CLO3. INITIATE SSME PURGING --------------------- 15-0425 -06H30M CLOX TBC INITIATE SSME PURGING PER SU72653 136 OMI S1003 ON OIS CH 156. TBC OTC 132 OTC CSME CCME 621 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0426 TBC JYVR STOP VIDEO RECORDINGS OF OTV COMM 138 CAMERAS 007/107,031/131,032/132, 038/138,039/139,040/140,056/156 (G3151 AND G3251). START VIDEO RECORDING OF OTV CAMERAS FOR CRYO LOADING (OMI S1003 AND S1004) (SEE CLHY/CLOX FIGURE 4) LAUNCH CONFIGURATION. CAMERAS: 001/101,034/134,049/149,050/150,051/151 PSEUDO INIT ----------- 15-0427 CGLS VERIFY 1 AVAILABLE CONCURRENCY. HOME CMD KEY - PRESS SLPP1 PERF PGM KEY - PRESS (KSCA OR KSCB) XMIT RESP KEY - PRESS CURSOR CNTL PSEUDO INIT XMIT CURSOR KEY - PRESS POSITION CURSOR TO ALL PSEUDOS XMIT CURSOR KEY - PRESS NOTE IF PAGE B MSG INDICATES: "SEE PAGE A FOR OPERATOR INPUT" PERFORM THE NEXT TWO STEPS. 15-0428 CGLS CRT VERIFY PAGE A MSG: (N03IS511E) CRYO SAFING ENABLED IS ON. THIS INDICATES SCRUB/CRYO DRAIN IN PROGRESS. NOT PERFORMED ______ 622 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0429 CGLS CONSOLE KYBD ENTER "1" IF CRYO SAFING SUPPORT COMPLETED AND SLP50 NOT ACTIVE TO INITIALIZE (N03IS511E) TO OFF. ENTER "2" TO LEAVE (N03IS511E) UNCHANGED _____ (1 OR 2) XMIT RESPONSE KEY - PRESS CRT VERIFY MSG INDICATING PSEUDO STATE NOT PERFORMED ______ 15-0430 CGLS VERIFY ALL SELECTED BLOCKS INVERTED AND NO EXCEPTIONS PG-A TERMINATE XMIT CURSOR KEY - PRESS TERMINATE XMIT CURSOR KEY - PRESS 15-0431 CGLS LPS GLS PSEUDO INIT IS COMPLETE. 127 PLEASE NOTE IN THE LPS LOGS FOR FUTURE SLP50 INITIATION. 623 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CL RSYS MONITOR ACTIVATION -------------------------- NOTE GLS PSEUDO INIT MUST BE COMPLETE PRIOR TO SLP50 ACTIVATION. 15-0432 NTD LPS ACTIVATE SLP50/SA001. SU72639| 232 | NOTE PERFORM NEXT TWO STEPS IF SLP50 IS ACTIVE DUE TO SCRUB/LH2 BOIL OFF OPERATIONS. 15-0433 LPS C1MC VERIFY 1 ADDITIONAL CONCURRENCY AVAILABLE PFP (SLP50) PFP2 KEY - RECYCLE COMPLT - PRESS CRT (SLP50 PAGE A) VERIFY MESSAGE RECYCLE FUNCTION COMPLETE AUTO RESPONSE TO ALL CONSOLE FAILURES RESUMED MANUAL RSYS XFER/SAFING CAPABILITY ACTIVE NOT PERFORMED ______ 624 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM FOLLOWING STEP IF PGM SA001 NOT AUTOMATICALLY INITIALIZED. 15-0434 LPS C1MC CRT (SLP50 PAGE A) VERIFY MESSAGE PSEUDO NLHK0706 IS ON, INDICATING SA001 ALREADY ACTIVE, SPECIFY WHETHER TO PROCEED: 1 - ACTIVE SA001 2 - DO NOT ACT SA001 NOW CONSOLE KYBD 1 XMIT RESP KEY - PRESS CRT VEIFY PGM SA001 ACTIVE VERIFY MESSAGE CRYOGENIC RECOVERY FUNCTION WILL BE HANDLED BY SA001. CRYO SAFING RESPONSE DISABLED. NOT PERFORMED ______ NOTE PERFORM NEXT 16 STEPS | AS APPLICABLE IF SLP50 IS NOT ACTIVE. 15-0435 LPS C1MC VERIFY NEXT PGM WILL COME UP IN CONCURRENCY 5. NOT PERFORMED ______ 15-0436 LPS C1MC PERFORM PROGRAM SLP50 AT MSTR CONSOLE. NOT PERFORMED ______ 625 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0437 C1MC PVO XMIT CMD KEY - PRESS N03IS510E RECORD VALUE__________ N03IS511E RECORD VALUE__________ NLHK0706X RECORD VALUE__________ NOT PERFORMED ______ 15-0438 C1MC HOME CMD KEY - PRESS SLP50 - PERF PGM KEY - PRESS NOT PERFORMED ______ 15-0439 C1MC VERIFY CONCURRENCY 6 AVAILABLE FOR SA001 ACTIVATION. NOT PERFORMED ______ 626 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS IF PSEUDO VALUES ARE AS FOLLOWS: N03IS510E = OFF AND N03IS511E = OFF 15-0440 C1MC CRT (SLP50, PAGE A) VERIFY ONE ADDITIONAL CONCURRENCY AVAILABLE IF OPTION 1 WILL BE SELECTED. SPECIFY CURRENT TEST CONFIGURATION 1 - FOR TERMINAL COUNT THIS IS THE TIME PERIOD FROM JUST PRIOR TO THE START OF CRYO TANKING (T-6HR) THRU GLS SECURING. 2 - CRYO DRAIN SUPPORT THIS IS THE TIME FROM GLS SECURING THRU LH2 BOILOFF COMPLETE. LH2 BOILOFF COMPLETE IS APPROX T+18 HR FROM INITIATION OF THE SCRUB. NOT PERFORMED ______ 15-0441 C1MC CONSOLE KYBD 1 - XMIT RESP - PRESS VERIFY - TERMINAL COUNT NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT SEVEN STEPS IF NEXT STEP DOES NOT OCCUR AUTOMATICALLY. 15-0442 C1MC VERIFY SA001 ACTIVE IN CONC 6. NOT PERFORMED ______ 627 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS IF PSEUDO VALUES ARE AS FOLLOWS: N03IS511E = ON 15-0443 C1MC CRT (SLP50, PAGE A) CURRENT PSEUDO FD CONFIGURATION INDICATES CRYO DRAIN SUPPORT. CONFIRMATION OF CORRECT CONFIGURATION REQUESTED. SELECT ONE OF THE FOLLOWING: 1 - FOR TERMINAL COUNT THIS IS THE TIME PERIOD FROM JUST PRIOR TO THE START OF CRYO TANKING (T-6HR) THRU GLS SECURING. 2 - CRYO DRAIN SUPPORT THIS IS THE TIME FROM GLS SECURING THRU LH2 BOILOFF COMPLETE. LH2 BOILOFF COMPLETE IS APPROX T+18 HR FROM INITIATION OF THE SCRUB. NOT PERFORMED ______ 15-0444 C1MC CONSOLE KYBD 1 - XMIT RESP - PRESS NOT PERFORMED ______ 15-0445 C1MC CRT (PAGE A) VERIFY MESSAGE SELECTED - TERMINAL COUNT NOT PERFORMED ______ 628 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS IF PSEUDO VALUES ARE AS FOLLOWS: N03IS510E = ON 15-0446 C1MC CRT (SLP50, PAGE A) CURRENT PSEUDO FD CONFIGURATION INDICATES GLS HAS ISSUED THE TERM LOX REPL (T-4/55). CONFIRMATION OF CORRECT CONFIGURATION REQUESTED. SELECT ONE OF THE FOLLOWING: 1 - FOR TERMINAL COUNT THIS IS THE TIME PERIOD FROM JUST PRIOR TO THE START OF CRYO TANKING (T-6HR) THRU GLS SECURING. 2 - CRYO DRAIN SUPPORT THIS IS THE TIME FROM GLS SECURING THRU LH2 BOILOFF COMPLETE. LH2 BOILOFF COMPLETE IS APPROX T+18 HR FROM INITIATION OF THE SCRUB. NOT PERFORMED ______ 15-0447 C1MC CONSOLE KYBD 1 - XMIT RESP - PRESS NOT PERFORMED ______ 15-0448 C1MC CRT (PAGE A) VERIFY MESSAGE SELECTED - TERMINAL COUNT NOT PERFORMED ______ 629 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT TWO STEPS IF PSEUDO VALUES ARE AS FOLLOWS: NLHK0706X = ON 15-0449 C1MC CRT (SLP50, PAGE A) PSEUDO NLHK0706X IS ON, INDICATING SA001 ALREADY ACTIVE. SPECIFY WHETHER TO PROCEED WITH SA001 ACTIVATION. 1 - ACTIVATE SA001 REGARDLESS OF THE PSEUDO VALUE 2 - DO NOT ACTIVATE SA001 NOW NOT PERFORMED ______ 15-0450 C1MC CONSOLE KYBD 1 - XMIT RESP KEY - PRESS VERIFY MESSAGE CRYOGENIC RECOVERY FUNCTION WILL BE HANDLED BY SA001. CRYO SAFING RESPONSE DISABLED. PFP VERIFY TASK SA001 NOT PERFORMED ______ 15-0451 C1MC LPS PROGRAMS ACTIVE AT MSTR: SLP50 (ACTIVE OR INACTIVE) SA001 (ACTIVE OR INACTIVE) 630 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE | | PERFORM NEXT STEP IF | AUTOMATIC RCL RSYS TRANSFER | IS ACTIVE. | | 15-0452 LPS CTPE PERFORM AUTOMATIC RSYS XFER INHIBIT. | | CTPE PFP (SAP27) | PFPK1 - PRESS (INH AUTO RCL XFER) | | NOT PERFORMED ______| 15-0453 LPS NTD SLP50 CL RSYS/CONSOLE CRASH PGM 232 ACTIVE. NTD OTC TBC OTC CTPE 132 TBC CLOX 136 CLHY 15-0454 LPS NTD SA001 LO2/LH2 CONSOLE MONITOR HAS 232 BEEN INITIATED. NTD OTC TBC OTC CTPE 132 TBC CLOX 136 CLHY 631 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0455 LPS VERIFY HIM VAN SPARES AND RADIO (NET 102) OPERATION. 15-0456 LPS C1MC PERFORM $FEPCPR DEMAND UPDATE FOR ALL 127 FEPS PER OMI C2000. TERM $FEPCPR AT COMPLETION OF DEMAND UPDATE. 15-0457 LPS VERIFY ALL REDUNDANT SWITCHES ACTIVE. 15-0458 LPS CPDR SWITCH TO ERROR-FREE TAPES FOR CLDB PDR AND LDBM RECORDING. INHIBIT HIM'S ------------- 15-0459 LPS INHIBIT FOLLOWING HIM'S ON GROUND DATA BUS 2/22 FROM POLLING BY GS3A FEP: HIM PAD A OCTAL PAD B OCTAL --- ----------- ----------- 6396 222 275 6397 023 303 6398 032 311 6399 233 316 8020 224 320 8022 025 325 FUEL CELL ACTIVATION - COMPLETE ------------------------------- NOTE DO NOT PERFORM NEXT THREE STEPS IF A RECYCLE OCCURRED AND FUEL CELLS REMAINED ACTIVE. 15-0460 -06H30M CFCP OTC ORBITER FUEL CELL ACTIVATION AND SU72619 132 CONFIGURE TO MAIN BUS LOAD OTC NTD SHARING COMPLETE. 232 NOT PERFORMED ______ 632 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FUEL CELL PERFORMANCE CALIBRATION --------------------------------- /PRSD SYSTEM INTEGRITY CHECK ---------------------------- 15-0461 OTC CFCP PERFORM FUEL CELL PERFORMANCE SU72615 132 CEPD CALIBRATION AND SYSTEM INTEGRITY SU72630 CHGD CHECK PER S0007VL4 (SEQ 69). (30 MIN) OMRS V45CH0.020-1R OMRS V45CH0.030-1 NOT PERFORMED ______ 15-0462 OTC CECL MONITOR HEAT LOAD IMPACT DURING 132 FUEL CELL PERFORMANCE CALIBRATION. NOT PERFORMED ______ SRSS STATUS ----------- 15-0463 TBC CBRS VERIFY RANGE SAFETY SYSTEM SU72649 136 STATUS: SRB: (LEFT AND RIGHT) --------------------- S&A SAFE - ON, ARM - OFF BATTERY A VOLTS - 31.6 VDC MIN. BATTERY B VOLTS - 30.0-35.9 VDC BATTERY CURR A .04 AMP BATTERY CURR B .04 AMP BATTERY TEMP RCVY 34.6-103.4 INHIBIT A - ON INHIBIT B - ON OMRSD S00FA0.510-1 IMU OPERATE/ATT DET COMPLETE ---------------------------- 15-0464 -06H21M CGNC OTC IMU OPERATE/ATT DET COMPLETE. SU72620 132 633 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE IMU OPERATE LCC EMON ----------------------------- 15-0465 CGNC APPL PG (SAB20/SWB02, PG-A) PFK13 KEY - PRESS(ACT EMON SETUP) 15-0466 CGNC CURSOR CNTL (SAB20/SWB02, PG-A) A-IMU OPERATE XMIT CURSOR KEY - PRESS 15-0467 CGNC APPL PG (SAB20/SWB02, PG-A) PFK13 KEY - PRESS(DE-ACT EMON SETUP) IMU POST OPERATE GYROCOMPASS ALIGN ---------------------------------- 15-0468 -06H21M OTC CGNC PERFORM IMU GYROCOMPASS ALIGN SU72623 132 PER OMI V1123. (42 MIN) RT OMI LOG NO.__________ NOTE PERFORM NEXT STEP IF DUAL MODE COOLING IS ACTIVE. 15-0469 OTC CECL VERIFY FREON COOLANT LOOP RADIATOR 132 INLET TEMPS ACCEPTABLE TO SUPPORT PAD CLEAR OPERATIONS. NOT PERFORMED ______ REMOVE CREW CMPT OIS -------------------- NOTE PERFORMANCE OF NEXT TWO STEPS WILL BE SCHEDULED REAL TIME. 15-0470 OTC ASP REMOVE OIS UNIT AND ASSOCIATED SU72635 132 *FCM CABLE FROM ORBITER CREW COMPARTMENT. (15 MIN) 15-0471 OTC *FCM WHEN DEPARTING PAD, TRANSPORT 132 CREW COMPARTMENT OIS UNITS AND ASSOCIATED CABLES TO COMPLEX J FOR UCOM PICKUP. 634 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLEAR WHITE ROOM/CREW CMPT -------------------------- NOTE VERIFY ALL CREW COMPARTMENT WORK COMPLETE PRIOR TO CLEARING WHITE ROOM/CREW COMPARTMENT. 15-0472 OTC CDR VERIFY READY TO CLEAR WHITE SU72636 132 ROOM/CREW COMPARTMENT. 15-0473 OTC NTD READY TO CLEAR WHITE ROOM AND CREW 232 COMPARTMENT. 15-0474 NTD *FLT VERIFY NO REQUIREMENTS FOR PERSONNEL 232 PTC SUPPORT FROM CREW MODULE OR WHITE TBC ROOM. 15-0475 NTD OTC CLEAR ALL PERSONNEL FROM WHITE ROOM 232 AND CREW COMPARTMENT TO A/B-11 ROADBLOCK. 15-0476 -06H20M OTC *FCM CLEAR ALL PERSONNEL FROM WHITE 132 CDR ROOM AND CREW COMPARTMENT TO ASP A/B-11 ROADBLOCK, EXCHANGE HAZARDOUS BADGES FOR PICTURE BADGES, THEN PROCEED TO FALLBACK AREA AND REPORT TO *PAD. (20 MIN) 15-0477 OTC *FCM PICK UP WHITE ROOM BEU'S 132 AND CREW COMPARTMENT OIS UNIT AND ASSOCIATED CABLES AND DELIVER TO COMPLEX J. 15-0478 -06H20M *FCM OTC CREW COMPARTMENT OIS UNIT, 132 ASSOCIATED CABLE AND BEU'S HAVE OTC NTD BEEN REMOVED FROM WHITEROOM. 232 15-0479 -06H20M OTC NTD ALL WHITE ROOM AND CREW COMPARTMENT 232 PERSONNEL CLEARING THRU A/B-11 NTD *SCC ROADBLOCK TO FALLBACK AREA AT THIS TIME. 635 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- REDUCE CABIN AIR TEMP --------------------- 15-0480 OTC CPVD REDUCE CABIN CONDITIONED AIR 132 TEMPERATURE TO 55 +/- 5 DEG F AT INTERFACE FOR CREW ENTRY. REPORT WHEN COMPLETE. RPS INST WORK AROUND SETUP -------------------------- 15-0481 OTC NTD REQUEST JRPS ON OIS CH 145 TO 232 SUPPORT CISL. NTD JRPS 15-0482 OTC CISL PERFORM OPERATION SUPPORT SETUP 6 - 132 INSTRUMENTATION LCC WORK AROUND CISL JRPS SETUP. START STRIP CHART ON PCM 145 DATA AND VERIFY DECOM LOCK ON 64 AND 128 KB DATA. (20 MIN) T:______ CONSOLE SOFTWARE CONFIGURATION ------------------------------ NOTE THE FOLLOWING CONSOLE PROGRAM ASSIGNMENTS ARE MINIMUM FOR TANKING. THESE ASSIGNMENTS ARE TO ASSIGN CONCURRENCY PRIORITIES. 15-0483 -06H20M NTD OTC VERIFY FR CONSOLE SOFTWARE SU72624 232 TBC ACTIVATION CONFIGURED PROPERLY PTC FOR T-06 HOURS. LPS 636 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAYLOAD PROGRAMS ---------------- NOTE PERFORM ONE OF THREE SUBSTEPS | IN NEXT STEP IF PAYLOAD CONSOLE PROGRAMS ARE ACTIVE. 15-0484 -06H20M PTC CLES VERIFY C-1 CONSOLE PROGRAMS ACTIVE 134 GLES DLES 1. FOR SPACEHAB (POWERED) PAH001 RS0002 RW0017 PAH001A PAH002 PAHLCCD NOT PERFORMED ______ SS1 2. FOR OTHER PAYLOADS RW0017 RA0003 RS0002 EA0013 NOT PERFORMED ______ SS2 3. FOR IUS | | RW0017 | UW0002 | UW0003 | UW0004 | RA0003 | UW0005 | | NOT PERFORMED ______| SS3 | | 15-0485 PTC NTD FR C1 CONSOLE SOFTWARE CONFIGURED. 232 637 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORBITER PROGRAMS ---------------- 15-0486 OTC CCSE VERIFY PROGRAMS 132 CNSE VWA40 ACTIVE IN C2 15-0487 OTC CPLE VERIFY PROGRAM 132 OVERVIEW 2 ACTIVE AT C5 15-0488 OTC CAFM VERIFY PROGRAM 132 VAK20 ACTIVE IN C5 VAK21 ACTIVE IN C5 15-0489 OTC CMPL VERIFY PROGRAM 132 SAE02 ACTIVE IN C3 15-0490 OTC CSME VERIFY PROGRAM 132 VAE38A ACTIVE IN C3 15-0491 OTC CMPS VERIFY PROGRAMS 132 VAE18 ACTIVE IN C4 SAE12 ACTIVE IN C4 15-0492 OTC CECL VERIFY PROGRAMS 132 VAG34 ACTIVE IN C5 VAG28 ACTIVE IN C5 VAG29 ACTIVE IN C5 VAG60 ACTIVE IN C5 (AUTO) 15-0493 OTC CPVD VERIFY PROGRAMS 132 VAM01A ACTIVE IN C6 VAM31A ACTIVE IN C6 15-0494 OTC CFCP VERIFY PROGRAMS 132 VWR05 ACTIVE IN C6 VWR70 ACTIVE IN C6 VWR04 ACTIVE IN C6 VWR06 ACTIVE IN C6 (EDO MISSIONS ONLY) 15-0495 OTC CGSS VERIFY PROGRAM 132 VAJ02 ACTIVE IN C7 VAJ14 ACTIVE IN C7 15-0496 OTC COOS VERIFY PROGRAMS 132 VADL7 ACTIVE IN C7 VADL8 ACTIVE IN C7 VADL9 ACTIVE IN C7 VADL0 ACTIVE IN C7 638 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0497 OTC CHYD VERIFY PROGRAMS 132 VWF19 ACTIVE IN C8 VAF43 ACTIVE IN C8 15-0498 OTC CAPU VERIFY PROGRAMS 132 VWF48 ACTIVE IN C8 VWF57 ACTIVE IN C8 15-0499 OTC CISL VERIFY PROGRAMS 132 SAQ04 ACTIVE IN C9 VAQ29 ACTIVE IN C9 15-0500 -06H20M OTC CHGD VERIFY PROGRAM 132 SAW01/HWW50 ACTIVE IN C9 15-0501 OTC CEPD VERIFY PROGRAMS 132 SWC02 ACTIVE IN C10 VWC17 ACTIVE IN C10 VWC10 ACTIVE IN C10 15-0502 OTC COFC VERIFY PROGRAMS 132 SAB19 ACTIVE IN C11 SAB20 ACTIVE IN C11 SAB21 ACTIVE IN C11 VABM1 ACTIVE IN C11 15-0503 OTC CDPS VERIFY PROGRAMS 132 SAS01 ACTIVE IN C12 VASP9 ACTIVE IN C12 VAS59 ACTIVE IN C12 VAS97 ACTIVE IN C12 639 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0504 OTC CCME VERIFY PROGRAM 132 VWE01 ACTIVE IN C12 15-0505 OTC CTPE VERIFY PROGRAMS 132 SAP10 ACTIVE IN INTG. SAP27 ACTIVE IN INTG. SAP29 ACTIVE IN INTG. SAP28 ACTIVE IN INTG. 15-0506 OTC TPE VERIFY PROGRAMS 132 SEP03 ACTIVE IN B/U SEP03 ACTIVE IN B/U SEP03 ACTIVE IN B/U SEP03 ACTIVE IN B/U 15-0507 OTC NTD FR CONSOLE SOFTWARE ACTIVATION 232 CONFIGURED FOR T-06 HOURS. SRB/ET PROGRAMS --------------- 15-0508 TBC CLOX VERIFY PROGRAMS 136 GAL01 ACTIVE IN C3 GAL02 ACTIVE IN C3 15-0509 TBC CLHY VERIFY PROGRAMS 136 GAH01 ACTIVE IN C4 GAH02 ACTIVE IN C4 GAW02 ACTIVE IN C4 15-0510 TBC CBRS VERIFY PROGRAMS 136 SARB4 ACTIVE IN C2 SWRB2 ACTIVE IN C2 15-0511 TBC CBHY VERIFY PROGRAM 136 BAT04 ACTIVE IN C8 15-0512 TBC CPWR VERIFY PROGRAMS 136 BWE08 ACTIVE IN C10 BWE11 ACTIVE IN C10 15-0513 TBC NTD FR CONSOLE SOFTWARE ACTIVATION 232 CONFIGURED FOR T-06 HRS. 640 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MASTER CONSOLE PROGRAMS ----------------------- 15-0514 LPS NTD PROGRAMS ACTIVE IN MSTR: 232 $HWMON (TCB1) AA008/AWP02 (TCB2) AA009/AWP01 (TCB4) SLP50 (TCB5) SA001 (TCB6) FAULT SUMM PAGE CLEAR --------------------- 15-0515 OTC CDPS PERFORM FAULT SUMMARY PAGE REVIEW 132 AND CLEAR. 15-0516 CDPS CURSOR CNTL (SAS01 PG-B) FAULT SUMMARY PAGE DISPLAY (VASE2) XMIT CURSOR KEY - PRESS CRT (SAS01 PG-B) VERIFY NO UNEXPLAINED FAULT MESSAGES APPL PAGE (SAS01 PG-B) PFK 2 KEY - PRESS 15-0517 CDPS CONSOLE KYBD DEUE DEST,GN,1,LDBA XMIT CMD KEY - PRESS DEUE SPEC 99 PRO XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS CRT (VAS59 PG-B) DEU 1 DISP ID = 990 15-0518 CDPS CONSOLE KYBD DEUE RESUME XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS 641 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE BT4 SNAPSHOT MAY BE PERFORMED DURING ORB/SRB/ET PIC RESISTANCE TEST PROVIDED SRB IGNITION S&A DEVICE VERIFICATION WILL NOT BE PERFORMED. 15-0519 -06H20M NTD OTC PERFORM BT4 SNAPSHOT ON ALL DPS SU72631 232 MDM'S. OTC CDPS 132 15-0520 CDPS CURSOR CNTL (SAS01 PG B) DPS XMIT CURSOR KEY - PRESS MDM DISCRETE OUTPUT CHECK (VAS94) XMIT CURSOR KEY - PRESS PFK 2 KEY - PRESS 15-0521 CDPS CURSOR CNTL (VAS94 PG B) T-3HR SNAPSHOT XMIT CURSOR KEY - PRESS NOTE PERFORM NEXT STEP UPON RECEIPT OF ORIGINAL COPY. 15-0522 CDPS PFP (VAS94) PFK 15 KEY - PRESS 15-0523 CDPS RETRIEVE BT4 ORIGINAL COPY FROM CONSOLE PRINTER. ANNOTATE PAGE NUMBERS ON COPY AND DELIVER TO DEV RUNNER. 15-0524 CDPS OTC T-6 HR SNAPSHOT PRIOR TO TANKING 132 COMPLETE. OTC NTD 232 642 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0525 OTC (PA LCC ONLY) PA T-6 HR BT4 SNAPSHOT COMPLETE. ALL SYSTEMS PLEASE REVIEW. VERBAL OK MUST BE RECEIVED PRIOR TO TANKING. 15-0526 CTPE BT4 TO BE DISTRIBUTED TO ALL SYSTEMS AS FOLLOWS: C2 - 2 COPIES FOR CCSE & CNSE C3/4 - 1 COPY FOR CMPS (IF LOADING PRELIMINARIES WERE COMPLETE) C5/6 - 5 COPIES FOR CPVD, CECL, CFCP, CAFM & CPLE C7/8 - 3 COPIES FOR COOS, CHYD AND CAPU C9/10 - 2 COPIES FOR CISL AND CEPD C11/12 - 4 COPIES FOR COFC, CGNC, CDPS AND CCME INTG - 1 COPY FOR TPE DEV RUNNER WILL PRODUCE COPIES AND DISTRIBUTE. 15-0527 OTC ALL ALL SYSTEMS LISTED BELOW TO SU72631 132 REVIEW MDM DISCRETE OUTPUT. VERBAL OK MUST BE RECEIVED BEFORE START OF TANKING. CCSE____ CAPU____ CAFM____ CISL____ CPLE____ CEPD____ CECL____ CGNC____ CPVD____ COFC____ CFCP____ CCME____ COOS____ CDPS____ CHYD____ CMPS____(N/A IF LOADING PRELIMINARIES STILL I/W) 643 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MONITOR GOX VENT SEALS ---------------------- 15-0528 TBC CMEC MONITOR GOX VENT SEALS 136 THROUGHOUT LOADING FOR ICE FORMATION AND GOX VAPOR LEAK PER S6444. IF A CONTINUOUS STEADY STREAM VAPOR LEAK OR SEAL FRETTING IS DETECTED, PERFORM EMERGENCY GOX VENT HOOD RAISE PER OMI G2158. OMRS S00FB0.350-1 OMRSD G51FG0000.104 OMRSD G61FG0000.104 START CLEARING - LDA -------------------- 15-0529 -06H20M NTD STM START CLEARING LAUNCH DANGER SEC 232 AREA OF ALL NONESSENTIAL SU72638 STM JSTC PERSONNEL FOR LAUNCH. SU72661 111 ESTABLISH ROAD BLOCKS AT A/B-10 SU72685 JSTC *SEC AND A/B-11 CONTROL POINTS. 114 NOTE PERSONNEL MAY REMAIN IN THE CCF AND NDTL FACILITIES UNTIL L-03H00M. SECURITY WILL VERIFY LDA CLEAR AT T-00H25M. 15-0530 NTD *SCC LDA CLEARING IN EFFECT BY SU72665 232 SECURITY. 15-0531 NTD LPS VERIFY LDBM SUBSYSTEM 232 IN DUAL BUS - REJECT LPS CLDB 127 644 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VERIFY ECS STATUS ----------------- 15-0532 OTC CPVD VERIFY ECS SYSTEM ON GN2 FOR 132 30 MINUTES, MINIMUM, PRIOR TO T-6 HOURS. OMRS S00FB0.050 OMRSD V05AG0.060-C OMRSD V05AH0.050-C OMRSD V05AI0.060-C 15-0533 -06H20M OTC CHGD VERIFY OXYGEN INDICATION LESS 132 THAN 10,000 PPM AND DECREASING IN THE FOLLOWING AREAS: ORBITER PAYLOAD BAY ORBITER MID-BODY ORBITER AFT VERIFY SAFING PANEL CONFIG -------------------------- 15-0534 CGLS HOME CMD KEY - PRESS $SYS PERF PGM KEY - PRESS LDBA XMIT CURSOR KEY - PRESS DETERMINE IF ALL OF THE FOLLOWING SAFING SEQUENCES: 0,2-14,16,18,20-24 ARE LOADED/NOT LOADED. (GREEN UP ARROW = LOADED) 15-0535 CGLS NTD LDB SAFING SEQUENCES ARE LOADED/ 232 NOT LOADED. NOTE PERFORM NEXT FOUR STEPS IF LDB SAFING SEQUENCES ARE NOT LOADED. 15-0536 NTD OTC VERIFY ALL CONSOLES READY FOR 232 TBC LDB SAFING SEQUENCES TO BE LOADED. NOT PERFORMED ______ 645 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0537 -06H20M OTC CPVD VERIFY YOUR LDB SAFING PANEL 132 CAPU CONFIGURED FOR SAFING SEQUENCE CEPD LOAD. COFC CGLS CMPS CMPL NOT PERFORMED ______ 15-0538 TBC CBHY VERIFY YOUR LDB SAFING PANEL 136 CLHY CONFIGURED FOR SAFING SEQUENCE LOAD. NOT PERFORMED ______ 15-0539 OTC NTD READY TO SUPPORT SAFING SEQUENCE TBC LOAD. 232 NOT PERFORMED ______ 15-0540 -06H20M NTD LPS AT LDBA AND LDBS FEPS - PRESS 232 RESET SWITCH ON VEHICLE SAFING INTERRUPT PANEL. VERIFY LIGHTS 0-31 OFF. NOTE PERFORM NEXT FOUR STEPS IF ANY LIGHTS REMAIN ON. 15-0541 LPS NTD VERIFY NO TCS SEQUENCES RUNNING. 232 NTD OTC OTC CDPS 132 NOT PERFORMED ______ 646 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0542 CDPS CRT (VAS59, PG-B) VERIFY TCS STATUS INACTIVE. NOT PERFORMED ______ 15-0543 LPS NTD LDB FEP WILL BE MOMENTARILY 232 INHIBITED TO RESET SAFING LIGHTS. REQUEST PERMISSION TO PROCEED. NOT PERFORMED ______ NOTE LDB I/O ERRORS WILL OCCUR IF NEXT STEP IS PERFORMED. 15-0544 -06H20M LPS C1MC CONSOLE KYBD I DA LDBA - XMIT CMD/EXEC CMD A DA LDBA - XMIT CMD/EXEC CMD AT LDBA AND LDBS FEPS - PRESS RESET SWITCH ON VEHICLE SAFING INTERRUPT PANEL VERIFY LIGHTS 0-31 ARE OFF NOT PERFORMED ______ 15-0545 LPS NTD LDB SAFING RESET COMPLETE. 232 NTD OTC TBC 15-0546 LPS C1SE VERIFY ALL PDM'S SET 127 TO READ POSITION. 647 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM LDB-FEP SAFING LOAD IF LDB HARDWIRE SAFING SEQUENCES ALREADY LOADED AND CMD ENABLE SW IS ENABLED. LDB-FEP SAFING LOAD ------------------- NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT 10 STEPS IF LDB HARDWIRE SAFING SEQUENCES ALREADY LOADED BUT COMMAND ENABLE IS REQUIRED. 15-0547 -06H15M OTC CGLS PERFORM LDB SAFING LOAD. SU72626 132 (15 MIN) NOT PERFORMED ______ 15-0548 CGLS LPS REPORT CURRENT LDB FEP CONFIGURATION. 127 FEP _____=LDB-A SWITCH POS. FEP _____=LDB-B NOT PERFORMED ______ 15-0549 CGLS OC PG ($SYS) CURSOR CNTL LDBA LDBA FEP REF. DES. __________ LDB CMD ENABLE SWITCH SHOULD BE IN __________ POSITION FOR THIS TEST. NOT PERFORMED ______ 15-0550 CGLS NTD LDB CMD ENABLE WILL GO TO ENABLE 232 ON MY MARK 5-4-3-2-1 MARK NOT PERFORMED ______ 648 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE IF ANY LIGHTS ARE FOUND ON IN NEXT STEP, DO NOT PROCEED WITHOUT NTD/SPE CONCURRENCE. 15-0551 LPS C1SE VERIFY LIGHTS 0-31 OFF AT LDB FEP 127 SAFING INTERRUPT PANELS AND NO UNEXPECTED SYSTEM MESSAGES AT MSTR CONSOLE. NOT PERFORMED ______ 15-0552 LPS NTD HAVE INTG CONSOLE PLACE LDB CMD 232 ENABLE SWITCH IN CENTER POSITION NTD CGLS (OFF). NOT PERFORMED ______ 15-0553 CGLS SLPP1 PERF PGM KEY - PRESS (KSCA OR KSCB) XMIT RESP KEY - PRESS VERIFY SLPP1 ACTIVE SELECT APP PG B FOR SLPP1 VERIFY INTEGRATED MENU NOT PERFORMED ______ 15-0554 CGLS CURSOR CNTL HARDWIRE SAFING XMIT CURSOR - PRESS CRT LDB-FEP SAFING SEQ NOT PERFORMED ______ 649 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE THE FOLLOWING SAFING SEQUENCES SHALL BE LOADED. O COMMAND LS HOLD/RECYCLE ALL HYDRAULICS SAFING SEQUENCES (2,3) ALL MPS LOX SAFING SEQUENCES (4,5,6,7) ALL MPS LH2 SAFING SEQUENCES (8,9,10,11,12,13) 14 FUEL CELL 1 OFF 16 FUEL CELL 2 OFF 18 FUEL CELL 3 OFF ALL ORBITER VENT DOORS SAFING SEQUENCES (20,21,22) ALL MPS LOX SAFING SEQUENCES (CONT) (23,24) 15-0555 CGLS CURSOR CNTL SELECT ALL SEQ'S XMIT CURSOR KEY - PRESS PFP SLPP1 KEY - PRESS PFP (SLPP1) PFPK1 (EXECUTE) - PRESS CRT VERIFY CURSOR BLOCK SOLID GREEN FOR ALL SELECTIONS MADE CURSOR CNTL TERMINATE XMIT CURSOR KEY - PRESS TERMINATE XMIT CURSOR KEY - PRESS VFY SLPP1 INACTIVE NOT PERFORMED ______ 650 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0556 CGLS OC PG ($SYS) CURSOR CNTL LDBA VERIFY GREEN ARROWS FOR ALL SEQ SELECTED HARDCOPY KEY - PRESS NOT PERFORMED ______ CAUTION NEXT STEP WILL ENABLE ALL LDB SAFING SWITCHES. NOTE SWITCH POSITION IN FOLLOWING STEP IS THE ACTIVE LDB FEP. 15-0557 CGLS ON INTEGRATION SAFING PANEL CMD ENABLE SW - _______(LDB-A OR LDB-B) NOTE IF A CHANGE OCCURS RESULTING IN A SWITCH OF ACTIVE LDB FEPS, LPS MUST NOTIFY CGLS OF NEW ACTIVE FEP AND NEW SWITCH POSITION. 15-0558 CGLS OTC LDB-FEP SAFING SEQUENCES LOADED SU72626 132 AND ALL SAFING SWITCHES ENABLED. OTC NTD 232 132 ALL NTD TBC 232 PTC TBC ALL 136 PTC ALL 134 LDB-FEP SAFING LOAD COMPLETE ---------------------------- 651 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONTROL LOGIC INHIBIT --------------------- 15-0559 OTC CGLS PERFORM PROGRAM SAP92 FOR T-6H SU72640 132 REACTIVE CONTROL LOGIC INHIBIT, RCL STATUS, COMMAND ISSUANCE, STATUS DP/DA. (30 MIN) 15-0560 CGLS VERIFY 1 AVAILABLE CONCURRENCY AND 2 CONSECUTIVE OC TASKS. HOME CMD KEY - PRESS SAP92 PERF PGM KEY - PRESS 15-0561 CGLS PFP SAP92 - PRESS PFPK1 (STATUS CMD ISSU) - PRESS VERIFY BOTH PFPK LIGHTS ARE LIT, THEN CONTINUE 15-0562 CGLS PFPK2 (STATUS DP/DA) - PRESS VERIFY BOTH PFPK LIGHTS ARE LIT, THEN CONTINUE 15-0563 CGLS PFPK3 (T-6H RCL INHB) - PRESS VERIFY BOTH PFPK LIGHTS ARE LIT, THEN CONTINUE 15-0564 CGLS PFPK4 (T-6H RCL STATUS) - PRESS VERIFY BOTH PFPK LIGHTS ARE LIT, THEN CONTINUE NOTE PRESS FORM FEED ON PRINTER TO ENSURE ALL OUTPUT IS RECEIVED. RETRIEVE OUTPUT FROM CONSOLE PRINTER AND REVIEW FOR PROPER CONFIGURATION. 15-0565 CGLS TERMINATE SAP92 PFK15 - PRESS 15-0566 CGLS OTC COMPLETED IMPLEMENTATION OF SU72640 132 SAP92. 652 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RSS/RCVY BATT AMP-HR VERIFICATION --------------------------------- 15-0567 TBC CPWR PERFORM RSS/RCVY BATTERY AMP-HOUR SU72646 136 VERIFICATION. 15-0568 CPWR CONSOLE KYBD CDS ENABLE KEY - PRESS 15-0569 CPWR CONSOLE KYBD (HI-TRAX) CDS SIGN ON KEY - PRESS 15-0570 CPWR CONSOLE KYBD CDS BREAK KEY - PRESS ATHIS_(TCID)# CDS XMIT KEY - PRESS 15-0571 CPWR CRT VERIFY AMP-HRS REMAINING EXCEEDS AMP-HRS REQUIRED FOR LAUNCH (AHRL) FOR ALL BATTERIES. 15-0572 CPWR TBC RSS/RCVY BATTERY AMP/HOUR VERIFICATION COMPLETE. OMRSD S00FB0.370 15-0573 T-6H15M CAPU OTC APU HTR ACTIVATION COMPLETE. 132 15-0574 T-6H15M CAPU OTC APU SYSTEM SWITCH SCAN COMPLETE. SU72621 132 653 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VERIFY APU/RCS HTRS ON ---------------------- 15-0575 -06H15M OTC CAPU VERIFY APU HEATERS ON FROM GROUND 132 COMMAND FOR ALL THREE (3) APU'S 1. GAS GEN/FUEL HTR - A 2. LUBE OIL LINE HTR - A 3. TANK AND LINE HTR - B 15-0576 OTC COOS CRT (VWD73) 132 VERIFY HEATERS ON. CROSSFEED HEATERS A AUTO B AUTO AFT RCS JETS 1 AUTO 2 AUTO 3 AUTO 4 AUTO 5 AUTO FWD RCS JETS 1 AUTO 2 AUTO 3 AUTO 4 AUTO 5 AUTO 654 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FIRE CREW FALLBACK ------------------ 15-0577 -06H10M *SCC NTD FIRE COMBAT CREW FALLBACK TO FIRE 232 A/B-4 ROADBLOCK (PAD B LAUNCH), SU72667 NTD STM A-5 ROADBLOCK (PAD A LAUNCH). STM JSTC 111 JSTC JFIR 114 15-0578 *PSE *SCC ALL PERSONNEL HAVE CLEARED PAD NET AREA. YOU HAVE SAFETY CONCURRENCE 105 TO SOUND EMERGENCY EVACUATION *SCC NTD WARBLER. SAFETY WILL WAIT FOR FIVE 232 MINUTES AFTER WARBLER HAS SOUNDED, BEFORE DEPARTING PAD GATE. 15-0579 NTD SOUND EMERGENCY EVACUATION WARBLER FOR 30 SECONDS. 15-0580 NTD *SCC CONFIGURE B ROAD SAFETY WARNING LIGHT 232 TO RED. CONFIGURE WARNING LIGHTS AT *SCC *PSE A/B-5 AND A/B-11 ROADBLOCKS TO RED NET WHEN EVACUATING PAD. OBSERVE STROBE 105 LIGHT ATOP RSS TO VERIFY FUNCTIONING. 15-0581 *PSE *SCC RSS STROBE LIGHT FUNCTIONING. NET 105 *SCC NTD 232 CONFIGURE FOR MMT/LD WX BRIEFING -------------------------------- 15-0582 -06H10M NTD STM REQUEST RANGE WX SUPPORT BRIEFING 232 FOR ET LOAD. STM *WEA 231 15-0583 NTD *FLT MMT/LD WX BRIEFING WILL OCCUR IN 232 LD 10 MINUTES IN LCC RM 1R29 OR O&C RM 1144 MBR. 655 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0584 -06H10M NTD STM VERIFY WHEN READY TO SUPPORT SU72677 232 MMT/LD TELEVISED WX BRIEFING IN LCC RM 1R29 OR O&C RM 1144 MBR. NOTE VIDEO FOR WX BRIEFING AVAILABLE VIA REMOTE KEY PAD SELECTION AS FOLLOWS: 1. SOURCE 187-JSC MMT/LD WX BRIEFING 2. SOURCE 176-CCFF WEATHER TV 3. SOURCE 099-CCFF WEATHER VISION. PERFORM NEXT TWO STEPS IF WX BRIEFING IS IN LCC RM 1R29. 15-0585 STM JYVO VERIFY JSC WX BRIEFING FEED COMM 138 ON OTV SWITCHER SOURCE 187 AND READY FOR DISPLAY IN LCC RM 1R29. NOT PERFORMED ______ 15-0586 JYVO STM JSC WX BRIEFING FEED IS ON COMM 138 SOURCE 187. VIDEO FOR MMT/LD STM NTD WEATHER BRIEFING IN LCC RM 1R29 232 READY. NOT PERFORMED ______ NOTE PERFORM NEXT TWO STEPS IF WX BRIEFING IS IN O&C MBR. 15-0587 STM GYCC VERIFY JSC WX BRIEFING FEED COMM 111 ON 6TVM2274 AND READY FOR GYCC GYVO DISPLAY IN O&C MBR. PTP GYVW NOT PERFORMED ______ 656 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0588 GYVO GYCC VIDEO FOR MMT/LD WEATHER COMM GYVW BRIEFING IN O&C MBR READY. SU72677 PTP GYCC STM 111 STM NTD 232 NOT PERFORMED ______ HOLD COUNTDOWN CLOCK -------------------- 15-0589 -06H05M NTD CGLS HOLD CDC AT T-6 HR 00 MIN 00 SEC. 232 15-0590 CGLS HOME CMD KEY - PRESS CDTH - 0600/00 XMIT CMD KEY - PRESS DISABLE PAD OIS --------------- 15-0591 -06H05M NTD STM PAD CLEARED - DISABLE PAD ___ COMM 232 OIS-D. (5 MIN) SU72674 STM GYCC 111 GYCC JYCD 117 15-0592 JYCD GYCC OIS-D DEACTIVATED TO PAD. COMM 117 GYCC STM 111 STM NTD 212 657 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FUEL CELL PERFORMANCE CAL COMPLETE ---------------------------------- NOTE DO NOT PERFORM NEXT STEP IF A RECYCLE OCCURRED AND FUEL CELLS REMAINED ACTIVE. 15-0593 CFCP OTC FUEL CELL PERFORMANCE SU72615 132 CECL CALIBRATION AND PRSD SYSTEM SU72630 CEPD INTEGRITY CHECK COMPLETE. CHGD OMRSD V45CH0.020-1R OMRSD V45CH0.030-1 NOT PERFORMED ______ LOX/MPS LOADING PRELIMINARIES ----------------------------- COMPLETE -------- 15-0594 -06H00M CLOX TBC SSME PURGE SEQUENCE 3 INITIATED. SU72650 136 LOX ET AND MPS LOX LOADING TBC NTD PRELIMINARIES COMPLETE. READY 232 FOR LOX LOADING. NTD OTC LH2 PRECHILLDOWN OPS - COMPLETE ------------------------------- 15-0595 -06H00M CLHY TBC ET LH2 PRE-CHILLDOWN OPERATIONS SU72654 136 PER S1004 COMPLETE. READY TO TBC NTD PROCEED WITH FACILITY ORBITER 232 CHILLDOWN AND LH2 FLOW. NTD OTC OMRSD S00FB0.090-B-1 OMRSD S00FB0.290-1 OMRSD S00FB0.080-1R OMRSD S00FB0.070-1R OMRSD S00FB0.082-1R OMRSD S00FB0.083 OMRSD S00FE0.040-1 OMRSD S00FE0.050-1 OMRSD S00FA0.225 658 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE THE NEXT SEVEN STEPS WILL PERFORM A BT4 SNAPSHOT FOR THE MPS SYSTEM ONLY. LOX/ MPS LOADING PRELIMINARIES AND LH2 PRECHILL OPS MUST BE COMPLETE PRIOR TO PERFORMING A BT4 SNAPSHOT. DO NOT PERFORM NEXT SEVEN STEPS IF MPS REVIEWED THE BT4 SNAPSHOT AT T-6 HR AND 20 MIN. BT4 SNAPSHOT MAY BE PERFORMED DURING ORB/SRB/ET PIC RESISTANCE TEST PROVIDED SRB IGNITION S&A DEVICE VERIFICATION WILL NOT BE PERFORMED. 15-0596 NTD OTC PERFORM BT4 SNAPSHOT ON ALL DPS SU72632 232 MDM'S. OTC CDPS 132 NOT PERFORMED ______ 15-0597 CDPS CURSOR CNTL (SAS01 PG B) DPS XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS01 PG B) MDM DISCRETE OUTPUT CHECK (VAS94) XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 15-0598 CDPS CURSOR CNTL (VAS94 PG B) T-3 HR SNAPSHOT XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 659 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP UPON RECEIPT OF ORIGINAL COPY AND COPY 1. 15-0599 CDPS PFP (VAS94) PFK 15 KEY - PRESS NOT PERFORMED ______ 15-0600 CDPS OTC T-6 HR SNAPSHOT PRIOR TO TANKING FOR 132 MPS COMPLETE. READY FOR CMPS REVIEW. OTC NTD 232 NOT PERFORMED ______ 15-0601 CTPE BT4 TO BE DISTRIBUTED TO FOLLOWING SYSTEMS AS FOLLOWS: C3/4 - 1 COPY FOR CMPS INTG - 1 COPY FOR TPE NOT PERFORMED ______ 15-0602 OTC CMPS MPS REVIEW MDM DISCRETE OUTPUT. SU72632 132 VERBAL OK MUST BE RECEIVED PRIOR TO START OF TANKING. CMPS____________________ NOT PERFORMED ______ 660 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- BDA CLEAR - COMPLETE PAD A -------------------------- NOTE PERFORM NEXT STEP IF LAUNCHING FROM PAD A. 15-0603 -06H00M *SEC NTD ROADBLOCK A-5 CLEAR OF ALL PAD A SEC 232 BDA PERSONNEL. ROADBLOCKS NTD *SCC ESTABLISHED AT A-3, B-4, A-5, *SCC *PAC A-6, A/B-10, A/B-11 AND A/B-15 NET *PSC WITH SIGNAL LIGHTS ON FLASHING RED. 105 FLASHING RED. NOT PERFORMED ______ ESSENTIAL PERSONNEL ------------------- NONE - 0 BDA CLEAR - COMPLETE PAD B -------------------------- NOTE PERFORM NEXT STEP IF LAUNCHING FROM PAD B. 15-0604 -06H00M *SEC NTD ROADBLOCK B-4 CLEAR OF ALL PAD B SEC 232 BDA PERSONNEL. ROADBLOCKS SU72641 NTD *SCC ESTABLISHED AT B-3, B-4 (BDA), *SCC *PAC A/B-10, A/B-11 AND A/B-15. NET *PSC 105 NOT PERFORMED ______ ESSENTIAL PERSONNEL ------------------- NONE - 0 BDA CLEAR COMPLETE ------------------ 661 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM ORBITER, SRB PIC RESISTANCE TEST AND SRB IGN S&A DEVICE VERIFICATION - CONTINGENCY IF THE T-27 HR PIC TEST WAS NOT PERFORMED OR IF ORBITER AFT SRB FWD SKIRT WERE ACCESSED AFTER THE T-27HR PIC TEST. THE SRB IGN S&A PORTION OF THE TEST WILL BE PERFORMED IF SRB FWD SKIRT WAS ACCESSED AFTER THE T-27 HR PIC CHECK. ORBITER, SRB PIC RESISTANCE TEST -------------------------------- AND SRB IGN S&A DEVICE VERIFICATION - ------------------------------------- CONTINGENCY ----------- NOT PERFORMED ______ 15-0605 *PSE *SCC ALL PERSONNEL CLEAR OF BDA. YOU SU72683 NET HAVE SAFETY CONCURRENCE TO PERFORM 105 PIC RESISTANCE TEST AND SRB IGN S&A *SCC NTD ROTATION VERIFICATION. 232 NTD OTC TBC WARNING HAZARDOUS STEPS FOLLOW DUE TO PIC RESISTANCE TESTS AND SRB IGN S&A ROTATION. ALL PERSONNEL MUST BE CLEAR OF BDA BEFORE PROCEEDING. ORBITER PIC RESISTANCE TEST --------------------------- 15-0606 NTD OTC PROCEED WITH ORBITER/GSE PIC SU72629 232 RESISTANCE TEST. 662 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0607 OTC CEPD ALL PERSONNEL CLEAR OF BDA. 132 POWER UP GSE PIC RACKS AND PERFORM ORBITER/GSE PIC RESISTANCE TEST PER S0007 VL4 (SEQ 52) ON OIS CH 151. PIC RACK POWER DOWN ------------------- 15-0608 OTC CEPD CURSOR CNTL (VWC10) 132 GRD SYS - OFF XMIT CURSOR KEY - PRESS CRT (VWC10) VERIFY GND AND CPA VOLTAGES ARE LL 15-0609 CEPD OTC ORBITER/GSE PIC RESISTANCE TEST 132 COMPLETE. OTC NTD 232 15-0610 OTC CEPD PERFORM MEC PREFLT BITE EVALUATION. 132 15-0611 CEPD PERFORM CDS QLDB RETRIEVAL ON FD VERIFY NO MEC FAILURES SRB PIC TEST ------------ 15-0612 NTD TBC PROCEED WITH SRB PIC 232 RESISTANCE TEST PER S0007 VL4 (SEQ 48). (10 MIN) 15-0613 TBC CPWR ALL PERSONNEL CLEAR OF BDA. PERFORM 136 SRB PIC RESISTANCE TEST PER S0007 VL4 (SEQ 48) ON OIS CH 176. 15-0614 CPWR TBC SRB PIC RESISTANCE TEST COMPLETE. 136 TBC NTD 232 NTD OTC 663 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DOWNLIST FORMAT 42 IS REQUIRED FOR SRB IGN S&A DEVICE VERIFICATION. COORDINATE FORMAT CHANGE WITH CGNC SO AS NOT TO IMPACT IMU CALIBRATION. IF FORMAT 42 CONFLICTS WITH IMU'S, DO NOT PERFORM SRB IGN S&A DEVICE VERIFICATION. PERFORM NEXT SEVEN STEPS TO SUPPORT SRB IGN S&A DEVICE VERIFICATION ONLY. 15-0615 OTC NTD VERIFY READY FOR SWITCH TO 232 DOWNLIST FORMAT 42 TO SUPPORT 132 ALL SRB S&A DEVICE VERIFICATION. CGNC NTD TBC 232 TBC ALL 136 NOT PERFORMED ______ 15-0616 NTD OTC SWITCH TO DOWNLIST FORMAT 42. 232 OTC CDPS 132 NOT PERFORMED ______ 15-0617 CDPS CURSOR CNTL (SAS01 PGB) FMT 42 (VAS90) XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT (VAS59 PGB) FMT 42 ACTIVE NOT PERFORMED ______ 664 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0618 CDPS OTC TRANSITION TO DOWNLIST FORMAT 132 42 COMPLETE. OTC NTD 232 132 ALL NTD TBC 232 TBC ALL 136 NOT PERFORMED ______ WARNING BDA WILL BE CLEARED. CONTROLLED SWITCHING AND CONTROLLED LPS COMMANDS ARE IN EFFECT THROUGHOUT S&A DEVICE VERIFICATION. DO NOT PERFORM THIS TEST DURING A PHASE I OR II LIGHTNING ADVISORY. HAZARDOUS OPERATIONS FOLLOW. BDA CLEAR REMAINS IN EFFECT. 15-0619 NTD ALL SRB IGN S&A DEVICE VERIFICATION PA TEST WILL START MOMENTARILY. CONTROLLED SWITCHING AND CONTROLLED LPS COMMANDING IN EFFECT. NOT PERFORMED ______ 15-0620 NTD TBC PROCEED WITH SRB IGNITION S&A DEVICE 232 VERIFICATION PER S0007 VL4 (SEQ 61) TBC CPWR ON CH 176. 136 NOT PERFORMED ______ 665 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0621 CPWR TBC SRB S&A DEVICE VERIFICATION SU72629 136 COMPLETE. TBC NTD 232 NTD OTC NOT PERFORMED ______ ORBITER, SRB PIC RESISTANCE TEST -------------------------------- AND SRB IGN S&A DEVICE VERIFICATION - ------------------------------------- CONTINGENCY COMPLETE -------------------- MEC PRE-FLIGHT BITE ------------------- 15-0622 OTC CEPD CHECK MEC PRE-FLIGHT BITE. 132 15-0623 CEPD CURSOR CNTL (MEC/PIC AUTO TEST MENU) LAUNCH PREFLT BITE XMIT CURSOR KEY - PRESS 15-0624 CEPD PFP (VSC24) CONTINUE - PRESS CRT (VSC24) PORT 1 SUCCESSFUL PORT 3 SUCCESSFUL HARDCOPY 15-0625 CEPD PFP (VSC24) TERMINATE - PRESS 15-0626 CEPD VERIFY NO MEC FAILURES. 666 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE LCC MONITORING SOFTWARE -------------------------------- 15-0627 -06H00M TBC CPWR ACTIVATE LCC MONITORING 136 SOFTWARE. 15-0628 CPWR CURSOR CNTL (BDE08) LCC XMIT CURSOR KEY - PRESS CRT VERIFY LCC GREEN 15-0629 CPWR PFP (BWE11) PFPK3 KEY - PRESS LED 3 VERIFY LCC MONITOR ACT ACTIVATE AUTO ET OPS -------------------- 15-0630 CPWR PFP (BWE08) PFPK3 KEY - PRESS LED 3 VERIFY AUTO ET OPS ACT 15-0631 CPWR ET/SRB HEATER SAFING PANEL ET HEATERS BIPOD - ON 15-0632 CPWR TBC LCC MONITORING SOFTWARE ACTIVATION 136 COMPLETE. 667 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DPS TO DOWNLIST FORMAT 44/60 ---------------------------- (POST S&A DEVICE TEST) ---------------------- NOTE PERFORM NEXT FOUR STEPS TO RECONFIGURE TO FLIGHT FORMAT IF REQUIRED. IN NEXT FOUR STEPS DL FORMAT WILL BE 60 FOR ASCENT POWERED SPACEHAB MISSIONS AND 44 FOR ALL OTHERS. 15-0633 OTC NTD VERIFY READY TO SUPPORT FORMAT ______ 232 (44 OR 60). 132 ALL NTD TBC 232 PTC TBC ALL 136 NOT PERFORMED ______ 15-0634 NTD OTC TRANSITION BACK TO DOWNLIST 232 FORMAT ______ (44 OR 60). OTC CDPS 132 NOT PERFORMED ______ 15-0635 CDPS CURSOR CNTL (SAS01 PGB) FMT______ (44 OR 60) XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT (VAS59 PGB) SELECTED DL FMT ACTIVE NOT PERFORMED ______ 668 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0636 CDPS OTC TRANSITION TO DOWNLIST FORMAT 132 ______ (44 OR 60) COMPLETE. OTC NTD 232 NTD TBC PTC NOT PERFORMED ______ 15-0637 *SCC NTD ALL PERSONNEL CLEARED OF BDA. 232 YOU HAVE CONCURRENCE TO PROCEED WITH ET LOX AND LH2 LOADING. LAUNCH COMMIT CRITERIA VERIF ---------------------------- NOTE THIS VERIFICATION INCLUDES: - A REVIEW OF ALL VALID SYSTEM PARAMETERS FOR FAILURES/ UNFAVORABLE TRENDS. - A REVIEW OF ALL SYSTEM LOGS AND OPEN PAPER TO VERIFY NO CONSTRAINTS. - A VERIFICATION OF ALL SYSTEM OMRS. 15-0638 -06H00M NTD OTC VERIFY REQUIRED LAUNCH COMMIT SU72614 232 TBC CRITERIA VALID FOR START OF SU72628 PTC TANKING AT T-06 HOURS. STM CSPE RECORD: SRO *MIL NSTS 16007 REV_____ LPS CSPE AMENDMENT________ DIRECTIVES__________ 15-0639 STM JBFX VERIFY REQUIRED LAUNCH COMMIT WSSA 111 JSTC CRITERIA REQUIREMENTS FOR JSTC START OF TANKING. 669 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0640 JSTC JSEP VERIFY REQUIRED LAUNCH COMMIT JSTC 114 GSPN CRITERIA VALID FOR START OF ELEC JSAC TANKING. PNU JFIR AC *SEC FIRE SEC 15-0641 *SCB JSTC AIR PACK VAN LOCATED AT CPX J LS JSTC STM RED CREW PARKING LOT. 111 STM NTD 232 NOTE IF THE OXID AND FUEL OMS PROPELLANT TANKS EXCEED THE LCC LIMIT (15 PSID MAX) PRIOR TO OMS PROPELLANT TANK REPRESS, IT IS NOT A CONSTRAINT TO LCC VERIFICATION FOR COOS. OMS REPRESS WILL OCCUR AFTER PAD CLEAR FOR CRYO TANKING AND VALUES ARE EXPECTED TO MEET CRITERIA. 15-0642 OTC ALL VERIFY YOUR SYSTEM MEETS LAUNCH 132 COMMIT CRITERIA REQUIREMENTS FOR START OF TANKING PHASE AT T-6 HOURS. CCSE _____ CPVD _____ CEPD _____ CNSE _____ CFCP _____ COFC _____ CAFM _____ CGSS _____ CAFC _____ CPLE _____ COOS _____ CGNC _____ CMPL _____ CAPU _____ CCME _____ CMPS _____ CHYD _____ CODS _____ CSME _____ CHGD _____ CDPS _____ CECL _____ CISL _____ 670 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0643 PTC ALL VERIFY YOUR SYSTEM MEETS LAUNCH 134 COMMIT CRITERIA FOR START OF TANKING. FOR SPACEHAB: DLES _____ *STC _____ FOR IUS: | DLES _____ | AXTC _____ | ICTC _____ | | FOR OTHER: DLES _____ 15-0644 TBC ALL VERIFY YOUR SYSTEM MEETS LAUNCH 136 COMMIT CRITERIA REQUIREMENTS FOR START OF TANKING PHASE AT T-6 HOURS. CLOX _____ CLHY _____ CMEC _____ CPWR _____ CBHY _____ CISL _____ CBRS _____ REPORT LCC STATUS ----------------- 15-0645 -06H00M OTC NTD NO LAUNCH COMMIT CRITERIA TBC VIOLATIONS FOR CRYO TANKING. PTC STM *MIL LPS 232 15-0646 NTD CSPE VERIFY NO LAUNCH COMMIT CRITERIA 232 VIOLATIONS WHICH CONSTRAIN CRYO PROPELLENT LOADING. 15-0647 -06H00M NTD LD VERIFY GO FOR LO2 232 AND LH2 TANKING. 671 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- T-6 HR COUNTDOWN HOLD --------------------- 15-0648 -06H00M NTD OTC CDC HOLDING AT T-6 HOURS. DURATION (HOLDING) PA TBC OF HOLD WILL BE _____ HOURS 232 *MIL _____ MINUTES. STM PTC *SCC LPS *FLT 15-0649 STM *MIL PERFORM COMMUNICATION CHECK WITH 111 TPE ON OIS CH 161. NOTE PERFORM NEXT STEP AFTER CDC IS HOLDING. 15-0650 NTD CGLS SET CDC TO START COUNTING AT 232 _____ HR _____ MIN _____ SEC GMT. 15-0651 CGLS HOME CMD KEY - PRESS CDTC_____/__.OOO HHMM SS XMIT CMD KEY - PRESS 672 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TPDMS MONITOR COMPLETE | ----------------------- | | 15-0652 OTC CAFM OBTAIN TIRE PRESSURE REPORT BY THE 132 FOLLOWING PROCEDURE: | NOTE | | REFERENCE DAP 138 INSTRUCTIONS. | | TELNET SESSION COMMANDS ARE | CASE SENSITIVE. | | 1. LOGON TO TELNET SESSION VIA | DAP TERMINAL. | | 2. TO INVOKE TIME AND CYCLE PROGRAM | ENTER: | | RSHELL> (RVSI TAC) LOWER CASE | ENTER PASSWORD | | 3. AUTOMATED TIME AND CYCLE WINDOW | SELECT | TIRES -- > LEAK RATE CALCULATIONS | | 4. TIRE HISTORY REPORT WINDOW | ENTER | MISSION: _____ (STS NO.) | TIRE: _____ ('ALL' FOR 6 LOCAT) | (LEAVE S/N BLANK IF 'ALL') | | SELECT: COMMIT | | 5. LEAK RATE TRENDING REPORT WINDOW | SELECT: CALCULATE, THEN | SELECT: PRINT | | 6. PRINT DIALOG WINDOW | ENTER: PRINTER ID | (LCC1PTR OR LCC3PTR) | SELECT: PRINT | | 7. CLOSE WINDOWS, | AUTOMATED TIME AND CYCLE WINDOW | SELECT: QUIT | ENTER: RSHELL>EXIT | TO END SESSION. | 673 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 15-0652 VERIFY TIRE PRESSURE DECAY RATES CON'T ARE NOT GREATER THAN 0.3 PSI/DAY AND PROJECTED END OF MISSION TIRE PRESSURES ARE GREATER THAN: 325 PSIG MAIN 310 PSIG NOSE | RECORD PROJECTED END OF MISSION PRESSURES: LH NLG________ PSIG RH NLG________ PSIG 310 MIN 310 MIN LH INBD_______ PSIG RH INBD_______ PSIG 325 MIN 325 MIN LH OTBD_______ PSIG RH OTBD_______ PSIG 325 MIN 325 MIN ATTACH HARD COPY OF TIRE PRESSURE REPORT TO THIS OMI. OMRSD V51AG0.075-A OMRSD V51AG0.075-B OMRSD V51AG0.075-C OMRSD V51AG0.075-D OMRSD V51AG0.075-E OMRSD V51AG0.075-F 674 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FUEL CELL OPERATIONAL PURGE --------------------------- NOTE DO NOT PERFORM NEXT TWO STEPS IF RECYCLE OCCURED AND FUEL CELLS REMAINED ACTIVE. PERFORM FOLLOWING STEP APPROXIMATELY TWO HOURS AFTER FUEL CELL 2 IS PLACED ON MAIN BUS. 15-0653 -06H00M OTC CFCP PERFORM FUEL CELL TWO HOUR SU72616 (HOLDING) 132 OPERATIONAL PURGE ON OIS CH 153 PER OMI V1040.002. (15 MIN) NOT PERFORMED ______ 15-0654 CFCP OTC FUEL CELL TWO HOUR OPERATIONAL 132 PURGE COMPLETE. OTC NTD 232 NOT PERFORMED ______ 675 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RESUME CDC ---------- 15-0655 -06H00M NTD OTC CDC WILL START COUNTING AT T-6 (HOLDING) PA TBC HR IN FIVE MINUTES. 232 *MIL STM PTC *SCC LPS 15-0656 -06H00M NTD ALL THE STS-___ CDC IS AT T-6 HR AND (COUNTING) 232 COUNTING. PA 15-0657 NTD STM WX BRIEFING COMPLETE. SUPPORT COMM 232 JSC RELEASED. STM JYVO 138 111 GYCC GYCC GYVW PTP GYVO 15-0658 NTD STM REQUEST FORECAST OF STEADY STATE 232 SURFACE WIND SPEED IN SRB RETRIEVAL STM JBDY AREA AT TIME OF LAUNCH. 111 JBDY *WEA 231 15-0659 *WEA JBDY TIME OF FORECAST:______ 231 JBDY STM PREDICTED WINDS:______ KNOTS 111 STM NTD GUSTING TO:______ KNOTS 232 NTD LD DIRECTION:______ DEG OMRSD S00L00.085 676 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0000 SHUTTLE FINAL COUNTDOWN CONTROL ------------------------------- SEQUENCE (-06H THRU T-0) ------------------------ NOTE THIS IS ALSO COUNTDOWN RE-ENTRY POINT FOR 24 HOUR SCRUB/TURNAROUND OPERATIONS. THIS SEQUENCE MAY COMMENCE PRIOR TO SEQUENCE 15 COMPLETION AT NTD/OTC DISCRETION. OPERATIONS INVOLVING CRIT 1, 1R AND/OR 1S ITEMS ARE CONTAINED IN THE FOLLOWING SEQUENCE/STEPS. 16-0001 -06H00M CTIF TBC SET INITIAL CONFIG FOR ICE/FROST 136 MONITORING AND DEBRIS PER S6444 COMPLETE. 16-0002 TBC CTIF PERFORM ET TPS ICE/FROST AND DEBRIS 136 EVALUATION PER OMI S6444 ON CHANNELS 222,223,224 & 225. OMRS S00FB0.005-1 OMRS S00FB0.360-1 16-0003 CTIF JYVO SUPPORT OTV CAMERAS FOR ET TPS COMM 138 ICE/FROST INSPECTION PER S6444 ON CHANNELS 222,223,224 & 225 (SEE CICE FIGURE 4). 16-0004 TBC NTD EXTERNAL TANK READY FOR LO2/LH2 232 LOADING. 677 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DISABLE EXTERNAL PAGING TO CONTROL ROOMS ---------------------------------------- 16-0005 NTD STM DISABLE EXTERNAL PAGING TO COMM 232 ACTIVE AND BACKUP CONTROL STM GYCC ROOMS FOR S0007 (05 MIN). 111 GYCC JYCJ 117 HGDS H2 AND O2 STATUS --------------------- 16-0006 -06H00M OTC CHGD VERIFY NO INCREASE ABOVE BASELINE 132 FOR H2 AND O2 CONCENTRATION PRIOR TO START OF LO2/LH2 LOADING IN FOLLOWING VEHICLE COMPARTMENTS: ORBITER PAYLOAD BAY ORBITER MID-BODY ORBITER AFT FUSELAGE HGDS MONITORING --------------- 16-0007 -06H00M OTC CHGD MONITOR HGDS FOR REMAINDER OF 132 COUNTDOWN IN ALL VEHICLE COMPARTMENT AREAS. REPORT ANY H2 OR O2 INDICATIONS ON COMMAND CHANNEL 132. SAMPLE EACH VEHICLE AREA AT LEAST EVERY 30 MINUTES. SAMPLE SPAN, TEST AND ZERO REFERENCE GASES AT LEAST ONCE EVERY HOUR. IF H2 ZERO GAS BACKGROUND EXCEEDS +/- 60 PPM, PERFORM REMOTE AUTO CALIBRATION. OMRSD S00FA0.435 16-0008 JYCJ GYCC EXTERNAL PAGING HAS BEEN DISABLED COMM 117 TO ACTIVE AND BACKUP CONTROL ROOMS GYCC STM FOR S0007. 111 STM NTD 232 678 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VERIFY ECS STATUS ----------------- 16-0009 OTC CPVD VERIFY ORBITER GN2 PURGE MOISTURE 132 CONTENT LESS THAN 5 GRAINS/LB PRIOR TO ORBITER MPS CHILLDOWN AND RECORD: GN2 PURGE MOISTURE______GRAINS/LB (5 MAX) OMRSD S00FB0.050-1 READY FOR ET LO2/LH2 LOADING ---------------------------- 16-0010 OTC NTD ORBITER READY FOR LO2/LH2 LOADING. 232 NTD STM STM JCFM 111 ET LO2/LH2 LOADING ------------------ NOTE LOX LOADING MAY START PRIOR TO LH2 LOADING AS LONG AS LH2 IS IN SLOW FILL WHEN LOX REACHES 40 PCT OF THE PROJECTED LOAD. IF NOT, LOX LOADING MUST STOP UNTIL LH2 IS IN SLOW FILL. LH2 LOADING MAY BE DONE PRIOR TO THE START OF LOX LOADING. 16-0011 -06H00M NTD TBC PROCEED WITH ET LOX LOAD TO 232 REPLENISH PER OMI S1003 ON OIS CH TBC CLOX 156. REPORT COMPLETION OF 136 SIGNIFICANT MILESTONES. 16-0012 NTD TBC CONTROL AREA CLEARED AND YOU HAVE 232 SAFETY CONCURRENCE TO PROCEED WITH TBC CLHY S1004 FACILITY/ORBITER CHILLDOWN. 136 679 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LOX XFER LINE CHILLDOWN (S1003) ------------------------------ 16-0013 -06H00M CLOX TBC INITIATING LOX TRANSFER LINE SU72693 136 CHILLDOWN. TBC NTD 232 LH2 CHILLDOWN ------------- 16-0014 CLHY TBC NOTIFY CLHY IF LOSS OF ORBITER SU72703 136 AFT FUSELAGE PURGE OR PAYLOAD BAY TBC NTD PURGE DETECTED DURING LH2 LOADING 232 FROM T-06H TO T-01M57S. NTD OTC OTC CPVD 132 16-0015 -06H00M CLHY TBC INITIATING LH2 FACILITY/ORBITER 136 CHILLDOWN. TBC NTD 232 136 CHGD 680 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SUPPORT FALLBACK CONFIG (OSSU 3) -------------------------------- 16-0016 -06H00M STM PSTM PERFORM SUPPORT OPERATION COMM 111 GYCC SUPPORT SETUP 3 - FALLBACK JSTC JSTC CONFIGURATION - SUPPORT RED PNU JCFM CREW T-6 HRS THRU T-0. WW 127 LPS HEQ JSTC GSPN LS 114 JSWC PN NET GSHE ELEC 104 *SCB AC GSPS FA JSEP EH JSAC SU72752 GSFA LOG PMEH GSUP 16-0017 -06H00M STM JYVR START VIDEO RECORDING AS FOLLOWS: COMM 138 1. M-II RECORDERS CAMERA 001/101,009/109, 054/154,055/155,056/156, 060/160,061/161,063/163 2. S-VHS/VHS RECORDERS CAMERA 003/103,011/111, 019/119, 030/130, 072/172, STI-RSS ROOF, STI-C/S2 (ENGINEERING ANALYSIS) 16-0018 -06H00M NTD STM REQUEST JCFM TO PERFORM CMDPS 232 PRINTOUT. STM JCFM 111 16-0019 JCFM STM CMDPS PRINTOUT COMPLETE. 111 REQUIRED RECORDERS RUNNING. 681 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OMS PROP TANK REPRESS --------------------- NOTE NEXT TWO STEPS PERFORM LOMS/ROMS PROP TANK REPRESS AND ARE REQUIRED TO ENSURE OXID AND FUEL TANK PRESSURES MEET LCC REQUIREMENTS. 16-0020 -06H00M OTC COOS PERFORM OMS PROP TANK REPRESS SU72722 132 PER S0007VL4 (SEQ 51) (15 MIN). 16-0021 COOS OTC OMS PROP TK REPRESS COMPLETE. 132 OMRSD V43CF0.110-A OMRSD V43CF0.110-B 16-0022 -06H00M TBC CBHY VERIFY SRB NOZZLE FLEX BEARING AND 136 SRB NOZZLE TO CASE JOINT MEET OMRS TEMPERATURE REQUIREMENTS. CRT (BAT04) VERIFY SRB AFT SKIRT GN2 PURGE CURSOR CNTL T (BLOCK) XMIT CURSOR KEY - PRESS CRT (BAT04) NOTE DISPLAY OF FLEX BEARING TEMPERATURES RECORD FLEX BEARING TEMPERATURES ______B______ 60 - 115 DEG F ______B______ 60 - 115 DEG F ______B______ 60 - 115 DEG F ______B______ 60 - 115 DEG F OMRSD S00FA0.776-1 682 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0022 CRT (BAT04) CON'T NOTE DISPLAY OF NOZZLE TO CASE JOINT TEMPERATURES RECORD NOZZLE TO CASE JOINT TEMPERATURES ______N______ 75 - 115 DEG F ______N______ 75 - 115 DEG F ______N______ 75 - 115 DEG F OMRSD S00FA0.777-1R CURSOR CNTL (BAT04) SRB AFT SKIRT GN2 PURGE T (BLOCK) XMIT CURSOR KEY - PRESS NOTE DISPLAY OF PURGE SCHEMATIC NOTE NOTIFY TBC AND GSPN WHEN GN2 FLOW IS TO BE INITIATED. 16-0023 -06H00M TBC CBHY PERFORM SRB OPERATION SUPPORT SETUP 136 5 - SRB AFT SKIRT GN2 PURGE ACTIVATION AS TEMPERATURES REQUIRE. NOT PERFORMED ______ GN2 RECHARGERS/LN2 TANKER - COMPLETE ------------------------------------ 16-0024 -06H00M GSPN JSTC GN2 RECHARGER(S) AND LN2 PNU 114 TANKERS PLACED AND CONNECTED JSTC STM TO CCF-39 RECHARGE MANIFOLD. 111 QV:_____ QA 16-0025 -06H00M NTD STM PAD RESCUE TEAM STANDING BY IN SU72676 232 FIRE STATION NO. 2. FIRE STM JFIR 111 683 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 TO SLOW FILL (S1004) ------------------------ 16-0026 -05H50M CLHY TBC LH2 FACILITY/ORBITER CHILLDOWN SU72705 136 COMPLETE. INITIATING ET LH2 SLOW TBC NTD FILL TO 5 PCT SENSOR WET. 232 NTD STM STM JCFM 111 ORBITER MPS CHILLDOWN (S1003) ----------------------------- 16-0027 -05H50M CLOX TBC LO2 TRANSFER LINE CHILLDOWN SU72693 136 COMPLETE. STARTING ORBITER SU72695 TBC NTD MPS CHILLDOWN. 232 IMU PREFLIGHT CALIBRATION ------------------------- 16-0028 -05H25M OTC CGNC TAKE IMUS TO TERM/IDLE PER IMU SU72713 GYROCOMPASS ALIGNMENT SEQUENCE SU72715 OF OMI V1123. REPORT COMPLETION. (3 MIN) RT OMI LOG NO.__________ 16-0029 -05H22M OTC CGNC PERFORM IMU PREFLIGHT SU72717 CALIBRATION PER OMI V1123 (2H45M). RT OMI LOG NO.__________ LOX SLOW FILL (S1003) --------------------- 16-0030 -05H20M CLOX TBC ORBITER MPS CHILLDOWN COMPLETE. SU72695 136 BEGINNING SLOW FILL. LO2 SLOW SU72697 TBC NTD FILL START 232 NTD STM STM JCFM 111 GMT__________ 684 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0031 -05H15M CLHY TBC ET LH2 ECO SENSORS WET AT SU72709 136 GMT__________. LOX FAST FILL (S1003) --------------------- 16-0032 -05H10M CLOX TBC LOX TRANSITION TO FAST FILL SU72697 136 COMPLETE. NOW IN FAST FILL SU72698 TBC NTD TO 98 PCT. 232 NTD *SCC STM 16-0033 STM JCFM REQUEST JCFM TO PERFORM 5 MINUTE 111 MAGNETIC TAPE SAMPLE RUN. 16-0034 JCFM STM 5 MINUTE MAGNETIC TAPE SAMPLE RUN 111 COMPLETE. LH2 FAST FILL (S1004) --------------------- 16-0035 -05H00M CLHY TBC ET LH2 SLOW FILL TO 5 PCT SU72705 136 COMPLETE. TBC NTD 232 NTD STM STM JCFM 111 OMRSD S00FE0.100-1 OMRSD S00FE0.111-1 OMRSD S00FD0.121-B-1R 16-0036 CLHY TBC ET LH2 5 PCT SENSOR WET. SU72707 136 INITIATING ET LH FAST FILL TO TBC CISL 98 PCT. 136 TBC NTD GMT__________ 232 NTD STM STM JCFM 111 685 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MPS LH2 RECIRC PUMP ACTIVATION ------------------------------ (S1004) ------- NOTE LH2 RECIRC WILL NORMALLY BE ACTIVATED 15 MINUTES AFTER LH2 TRANSITIONS INTO FAST FILL. TIMES MAY VARY IF LH2 FAST FILL IS INTERRUPTED OR DELAYED. 16-0037 -05H00M CMPS OTC LH2 RECIRC PUMPS WILL BE ACTIVATED 132 MOMENTARILY. 16-0038 OTC CHGD MONITOR AFT COMPARTMENT AND ET 132 I/T (AUTO SEQUENCE) DURING RECIRC PUMP OPERATIONS FOR SIGNIFICANT CHANGES IN H2 CONCENTRATION. NOTE PERFORM NEXT STEP PRIOR TO RECIRC PUMP ACTIVATION. 16-0039 OTC CEPD CURSOR CNTL (VWC01) 132 AC S/R HI XMIT CURSOR KEY - PRESS CRT (VWC01) 1T100/200 VOLT SAMPLE RATE CHANGED TO 100/SEC 16-0040 -05H00M TBC CBHY CONFIGURE BAT04 FOR LAUNCH 136 COUNTDOWN. 686 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0041 CBHY CRT (BAT04) VEHCLE LEFT/RGHT ACTUATOR POSITN VERIFY LEFT A -.3 TO -.8 INCHES B58H1150C1 LEFT B -.3 TO -.8 INCHES B58H1151C1 RGHT A -.3 TO -.8 INCHES B58H2150C1 RGHT B -.3 TO -.8 INCHES B58H2151C1 16-0042 CBHY CURSOR CNTL (BAT04) C/D MDE XMIT CURSOR UNTIL - LNH LAPS DELIVERY ------------- 16-0043 -04H50M STM JSTC DELIVER FOLLOWING AT T-4 HRS LS 111 IN SEQUENCE: SU72754 JSTC *SCB NET 1. DELIVER 19 LAPS W/COMM AND 104 5 LAPS WITHOUT COMM TO FIRE STA NO. 2 BY T-4 HRS. 2. DELIVER 1 EA PORTABLE AIR VENTILATOR PER FLIGHT CREW MEMBER TO FIRE STATION NO. 2 FOR ASTRONAUT CLOSEOUT CREW. 3. DELIVER 2 EA LAPS TO AIR PACK VAN CX-J (CLOSEOUT CREW SPARES). 4. DELIVER 1 EA PORTABLE AIR VENTILATOR PER FLIGHT CREW MEMBER PLUS ONE TO O&C CUL-DE-SAC, ASTRONAUT CREW VAN AT T-4 HRS. 687 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MPS LH2 RECIRC PUMP ACTIVATION ------------------------------ COMPLETE -------- 16-0044 -04H40M CMPS OTC LH2 RECIRC PUMP ACTIVATION 132 COMPLETE. PASS PRE-FLT RCS QTY U/L ------------------------ NOTE DO NOT PERFORM NEXT TWO STEPS IF SCRUB TURNAROUND WAS PERFORMED AND RCS QUANTITY CORRECTION UPLINK NOT REQUIRED. 16-0045 NTD *FLT PERFORM PASS PREFLIGHT RCS QTY 232 CORRECTION UPLINK. NOT PERFORMED ______ 16-0046 *FLT NTD PASS PREFLIGHT RCS QTY CORRECTION 232 UPLINK COMPLETE. NTD OTC OTC CVFS 132 NOT PERFORMED ______ MILA ANTENNA ALIGN ------------------ 16-0047 -04H30M NTD *FLT 1. PERFORM MILA ANTENNA SU72718 232 *MIL ALIGNMENT ON OIS CH 232. OTC (1 HR) OTC CCSE 132 RCRT 2. MILA SELECT HARDLINE TM FOR TRANSMISSION TO MCC-H. 688 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE A/G VOICE LINKS AND U/L CMDS WILL BE INTERRUPTED DURING MILA ANTENNA ALIGN, FREQUENCY AND ANTENNA SWITCHING UNTIL MILA OBTAINS 2-WAY LOCK. IF FALSE LOCK OCCURS, MILA WILL REMOVE U/L MODULATION, REACQUIRE CARRIER LOCK AND RE-APPLY MODULATION. MCC COMAND WILL BE SENT VIA GNC MAJOR FUNCTION. 16-0048 NTD *MIL REPORT RF OUTPUT 232 _____ WATTS 16-0049 NTD *FLT TRANSMIT DSM ____ 232 (XPNDR FREQ HIGH DSM 4741 V74K3111 OR XPNDR FREQ LOW DSM 4740) 16-0050 CCSE VAA19 VERIFY XPNDR FREQ - ____ (HIGH OR LOW) NOTE MILA RF OUTPUT LEVEL MAY BE ADJUSTED TO ENABLE C&T STATION TO LOCK ON U/L SIGNAL FROM MILA. IF MONITOR RECEIVER DOES NOT LOCK TO UPLINK SIGNAL FROM MILA, ACQUISITION SWITCH ON MONITOR RECEIVER MAY BE TAKEN TO MANUAL AS REQUIRED. 16-0051 -04H30M NTD *MIL ACQUIRE 2-WAY LOCK ON S-BAND ____ 232 (HIGH OR LOW) FREQ (MODE 25K CODING) SET RF OUTPUT FOR C&T LOCK. RECORD MILA RF OUTPUT __________(BD) 16-0052 CCSE CRT (VAA19) VERIFY NSP FRAME SYNC LOCKED 689 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0053 RCRT LOCK RECEIVERS TO HIGH OR LOW FREQUENCY MILA UPLINK AND ORBITER DOWNLINK AS FOLLOWS: 1. 8216 PANEL A7 CHANNEL SW - __ (2=HIGH, 1=LOW) LOOP STATUS PM LITE - LOCKED PANEL A9 CHANNEL SW - __ (4=HIGH, 3=LOW) LOOP STATUS LITE - LOCKED 2. 8217 PANELS A4 AND A7 FRAME SYNC LOCKED LITES - ON T:______ 16-0054 NTD *FLT TRANSMIT DSM 4750 232 (PWR AMP STBY 1 - ON) 16-0055 CCSE VAA19 VERIFY PWR AMP STBY 1 ON 16-0056 NTD *MIL XPNDR FREQ SWITCH COMPLETE. MILA SWITCH TO SECONDARY ANT ---------------------------- 16-0057 -04H00M *MIL NTD SECONDARY ANTENNA ALIGN COMPLETE. 232 S-BAND WILL BE MOMENTARILY INTERRUPTED WHILE SWITCHING ANTENNAS. 16-0058 NTD *MIL PROCEED WITH ANTENNA SWITCHING. 232 OBTAIN VALID 2-WAY LOCK. 16-0059 *MIL NTD ANTENNA SWITCH COMPLETE; 2-WAY 232 LOCK OBTAINED. 16-0060 NTD CCSE VAA19 VERIFY 232 NSP FRAME SYNC - LOCKED 690 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0061 -04H00M NTD *MIL PROCEED WITH ANTENNA ALIGN. 232 LAPS DELIVERY COMPLETE ---------------------- 16-0062 -04H00M *SCB JSTC LAPS DELIVERED AS FOLLOWS: LS NET SU72754 104 1. (5) LAPS W/O COMM AND (3) | JSTC STM LAPS W/COMM TO FIRE STA NO. 2 | 111 FOR CLOSEOUT CREW. | 2. (16) LAPS W/COMM TO FIRE | STA NO. 2 FOR FLIGHT CREW | RESCUE TEAM. | | 3. (2) LAPS TO AIR PACK VAN | AT COMPLEX J. | ACTIVATE RADIO NETS ------------------- NOTE STM PERFORM NEXT THREE STEPS BY COUNT CLOCK AT T-4 HOURS. 16-0063 -04H00M STM GYCC VERIFY COMM CONFIGURED FOR COMM 111 CONVOY COMMANDER, PURGE AND GYCC GYCJ COOLING NETS AT KSC. 117 NOTE PERFORM NEXT STEP IF DFRF OR WSSH IS DESIGNATED ALTERNATE LANDING SITE. 16-0064 LRD STM ACTIVATE ALTERNATE LANDING SITE COMM 135 CONVOY COMMANDER NET TO ______ STM GYCC (DFRF/WSSH). REPORT COMPLETION. 111 GYCC GYCJ 117 NOT PERFORMED ______ 691 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0065 STM GYCC VERIFY KSC TRANSMITTERS/RECEIVERS COMM 111 FOR CONVOY CMDR, PURGE AND COOLING GYCC GYCJ NETS OPERATIONAL. 117 | NOTE THE LIST OF PERSONNEL IN THE LDA AT T-0 SHOULD INCLUDE THE NAMES OF INDIVIDUALS, THEIR LOCATION, FUNCTION AND ORGANIZATION. ANY DEVIATION TO THE APPROVED LDA ACCESS LIST MUST BE APPROVED BY NTD WITH SAFETY CONCURRENCE. 16-0066 -04H00M NTD STM PROVIDE LISTING OF PERSONNEL COMM 232 SRO WHO WILL REMAIN IN LDA THROUGH STM JSTC T-0 TO NTD. REPORT COMPLETE. 111 GYCC JPHO GYCC WYVS PTP 16-0067 STM GBHE PROVIDE NAMES OF ASTROVAN DRIVER HESA 111 AND SUPERVISOR. VERIFY WEATHER AIRCRAFT COMM TO JSC ----------------------------------- 16-0068 STM GYCC COMM CHECK 2RAC534 AND 2RAC1534 COMM 111 TO JSC USING OIS-D AND RADIO GYCC GYCJ AT CDSC. REPORT COMPLETION. 117 692 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MPS LH2 ET ULLAGE PRESSURE -------------------------- TRANSDUCER NUMBER 4 VERIF ------------------------- NOTE THIS TEST WILL NORMALLY BE PERFORMED AT APPROX T-4HRS WHEN LH2 TRANSITIONS INTO REDUCED FAST FILL. TIMES MAY VARY IF LH2 FAST FILL IS INTERRUPTED OR DELAYED. 16-0069 CMPS OTC NOTIFY BOOSTER CONSOLE THROUGH SU72699 132 *FLT SPARE LH2 ET ULLAGE PRESSURE OTC NTD TRANSDUCER WILL BE SWITCHED 232 INTO NUMBER 3 ET OI POSITION. NTD TBC *FLT 16-0070 *FLT NTD BOOSTER CONSOLE NOTIFIED. PROCEED 232 WITH LH2 ULLAGE PRESSURE TRANSDUCER NTD OTC SWITCH OUT. OTC CMPS 132 16-0071 CMPS OTC NOTIFY BOOSTER CONSOLE THROUGH *FLT 132 LH2 ET ULLAGE PRESSURE TRANSDUCER OTC NTD NUMBER 3 WILL BE SWITCHED BACK INTO 232 TBC NUMBER 3 ET OI POSITION NTD *FLT (NORMAL POSITION). 16-0072 *FLT NTD BOOSTER CONSOLE NOTIFIED. PROCEED 232 WITH LH2 ULLAGE PRESSURE TRANSDUCER NTD OTC SWITCHOUT. OTC CMPS 132 693 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0073 -03H45M CLHY TBC ET LH2 FAST FILL TO 98 PCT SU72707 136 COMPLETE. INITIATING ET LH2 SU72710 TBC NTD TOPPING TO 100 PCT. (S1004) 232 NTD STM STM JCFM 111 OMRSD S00FF0.011-1 OMRSD S00FF0.081-1 OMRSD S00FF0.030-1 OMRSD S00FF0.190-1 16-0074 CLHY TBC ET LH2 98 PCT SENSORS WET AT 136 TIME __________ GMT. TBC CPWR 16-0075 CLHY TBC LH2 IN TOPPING AND ET LH2 TANK SU72712 136 VENTED AND VENT VALVE CYCLING TBC NTD TERMINATED. READY FOR ORBITER 232 AND SRB PIC RESISTANCE TESTS. BIPOD HEATER ACTIVATION ----------------------- 16-0076 CPWR CRT (BDE08) VERIFY MESSAGE TIMER FOR TURNING ON BIPOD HTRS HAS STARTED 694 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE NEXT STEP WILL OCCUR APPROXIMATELY 4 MINUTES AFTER PRECEDING STEP. 16-0077 CPWR CRT (BDE08) VERIFY MESSAGE POWER UP OF THE BIPOD HEATERS IS IN WORK. 16-0078 CPWR CRT (BDE08) VERIFY ET HEATERS LEFT BIPOD 0.8-1.2 A RIGHT BIPOD 0.8-1.2 A OMRSD S00FF0.095 16-0079 CPWR TBC BIPOD HTRS ARE ACTIVATED SU72701 136 PIC RESISTANCE TESTS -------------------- NOTE NOTED REQUIREMENT IS SATISFIED BY THE FOLLOWING STEPS. OMRS S00FA0.015-1 16-0080 NTD OTC PROCEED WITH ORBITER/GSE PIC 232 RESISTANCE TEST. 16-0081 OTC CEPD POWER UP GSE PIC RACKS AND 132 PERFORM ORBITER/GSE PIC RESISTANCE TEST PER SEQ 52 ON CH 151. REPORT COMPLETION. 695 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0082 CEPD OTC ORBITER/GSE PIC RESISTANCE 132 TEST COMPLETE. GSE PIC OTC NTD RACKS WILL REMAIN POWERED UP. 232 16-0083 OTC CEPD PERFORM MEC PREFLT BITE EVALUATION. 132 16-0084 CEPD CURSOR CNTL (VWC10) MEC BITE PREFLT XMIT CURSOR KEY - PRESS CRT (SA PAGE) VERIFY NO MEC FAILURES 16-0085 CEPD PERFORM CDS QLDB RETRIEVAL ON FD VERIFY NO MEC FAILURES SRB PIC RESISTANCE TEST ----------------------- 16-0086 NTD TBC PROCEED WITH SRB PIC 232 RESISTANCE TEST PER S0007VL4 TBC CPWR (SEQ 48) ON CH 176. (15 MIN) 136 16-0087 CPWR TBC SRB PIC RESISTANCE TEST SU72712 136 COMPLETE. TBC NTD 232 16-0088 NOTED REQUIREMENT COMPLETE. OMRSD S00FA0.015-1 696 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ASSEMBLE FINAL INSPECTION TEAM AND ---------------------------------- CLOSEOUT CREW ------------- 16-0089 NTD CICE ASSEMBLE AND BRIEF FINAL 232 TBC INSPECTION TEAM FOR PAD ENTRY. TBC CTIF PROCEED TO COMPLEX J AND REPORT 136 WHEN READY. 16-0090 NTD OTC ASSEMBLE CLOSEOUT CREW AT SU72720 232 COMPLEX J. SU72736 NOTE OTC WILL VERIFY LO2 LOAD AT 90 PCT. WHEN ASSEMBLED AT COMPLEX J CLOSEOUT CREW LEADER (OVCC) WILL PERFORM NET 105 COMM CHECK WITH OTC. CLOSEOUT CREW WILL CARRY SPARE PORTABLE RADIO AND PORTABLE O2 DETECTOR FOR CONTINUOUS MONITORING OF O2 IN WHITE ROOM. 16-0091 NTD JFIR ASSEMBLE PAD RESCUE TEAM AT FIRE 232 A/B-11. 16-0092 -03H45M OTC *PAD ASSEMBLE CLOSEOUT CREW AT 132 COMPLEX J AND PREPARE FOR PAD RE-ENTRY. VERIFY ASP HAS SWITCH GUARD KEY. NOTIFY CLOSEOUT CREW TO PICKUP 6 LAPS FOR WHITE ROOM AND 8 ELSA'S FOR FSS ELEVATOR AT FIRE STATION NO. 2. 16-0093 -03H45M NTD *SCC GO TO OIS CH 221 AND DETERMINE 232 PREFERRED TRIAGE SITE FOR FINAL INSPECTION TEAM AND CLOSEOUT CREW USE. REPORT SITE________. 16-0094 -03H40M SRO NTD RANGE REQUESTS RANGE SAFETY COMMAND 232 READINESS CLEARANCE (APPROX 90 MIN). WILL REPORT COMPLETION. 697 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING PERSONNEL ENROUTE TO FORWARD OBSERVER SITES MUST NOT PENETRATE BLAST DANGER AREA. NOTE UPON ARRIVAL AT THEIR ASSIGNED LOCATION, PERSONNEL WITHIN LDA WILL REPORT ON OIS OR RADIO NET TO THEIR RESPECTIVE LEAD (NTD, SRO, STM, BEK1) FOR COMM CHECK. LEAD PERSONNEL WILL THEN VERIFY TO NTD THE STATUS OF THEIR RESPONSIBLE PERSONNEL. FOR ROAD BLOCK LOCATION (SEE FIGURE 5). FOR PERSONNEL LOCATIONS/MAXIMUM MANLOADING, SEE FIGURE 7. BEU'S WILL BE AVAILABLE FOR PICKUP AT LIFE SUPPORT SCAPE FACILITY BEHIND F/S NO. 2. 16-0095 -03H40M NTD STM HAVE PERSONNEL REPORT TO COMM 232 *SEC ASSIGNED FWD OBSERVER SITES. SEC STM JPHO BRIEF PERSONNEL THAT THEY SHALL 111 GYCC NOT PENETRATE BDA WHILE ENROUTE JSTC TO SITES (INFO JSTC). GYCC WYVS PTP 698 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- XPNDR SWITCH TO LAUNCH FREQ --------------------------- 16-0096 -03H30M *MIL NTD MILA ANTENNA ALIGN COMPLETE. 232 READY FOR XPNDR SWITCH TO LAUNCH FREQUENCY. 16-0097 NTD OTC REQUEST CCSE AND RCRT ON OIS 232 CH 232 FOR XPNDR SWITCH TO OTC CCSE LAUNCH FREQUENCY. 132 RCRT 16-0098 NTD *FLT TRANSMIT DSM ____ 232 (XPNDR FREQ - LOW DSM 4740 V74K3112 OR XPNDR FREQ HIGH DSM 4741) 16-0099 CCSE VAA19 VERIFY XPNDR FREQ - _____ (LOW OR HIGH) 16-0100 NTD *MIL ACQUIRE 2-WAY LOCK ON S-BAND ____ 232 (HIGH OR LOW) FREQ (MODE 25S CODING) AT LEVEL RECORDED AT START OF ANTENNA ALIGN (ANTENNA POSITIONED FOR LAUNCH) RECORD _____ WATTS. 16-0101 CCSE VAA19 NSP FRAME SYNC - LOCKED 699 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0102 RCRT LOCK RECEIVERS TO HIGH OR LOW FREQUENCY MILA UPLINK AND ORBITER DOWNLINK AS FOLLOWS: 1. 8216 PANEL A7 CHANNEL SW - __ (1=LOW, 2=HIGH) LOOP STATUS PM LITE - LOCKED PANEL A9 CHANNEL SW - __ (3=LOW, 4=HIGH) LOOP STATUS LITE - LOCKED 2. 8217 PANELS A4 AND A7 FRAME SYNC LOCK LITES - ON T:______ 16-0103 NTD *FLT TRANSMIT DSM 4752 232 (PWR AMP STBY 2 - ON) 16-0104 CCSE VAA19 VERIFY PWR AMP STBY 2 ON 16-0105 NTD *MIL SELECT RF 192 KB DATA TO 232 MCC-H. 16-0106 NTD *FLT VERIFY PROCESSING 192 KBS RF 232 DOWNLINK TELEMETRY AND VOICE. 16-0107 -03H30M NTD JRPS VERIFY LOCK ON MILA CMD VERIFY 232 AND MILA 192 KB D/L DATA. VERIFY RECORDING MILA S-BAND PM-1 AND PM-2 192KB RF DATA. 16-0108 NTD *FLT MILA ANTENNA ALIGNMENT COMPLETE. SU72718 232 *MIL RCRT CCSE OTC 700 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0109 OTC CCSE ACTIVATE COUNTDOWN EMONS 132 PROGRAMMABLE FUNCTION PANEL VWA40 PFPK - PRESS VERIFY EMONS DISPLAYED EMONS PFPK - PRESS ACT CNT-DN EMON PFPK - PRESS CRT (VWA40 PG B) VERIFY MSG CNT-DN EMON ACTIVATED PROGRAMMABLE FUNCTION PANEL EXIT EMON OPTIONS PFPK - PRESS PFPK7 - PRESS 16-0110 CCSE CURSOR CNTL (VWA40) F/S MONITOR XMIT CURSOR KEY - PRESS CRT VERIFY F/S MONITOR INVERT 16-0111 -03H30M NTD *FLT PERFORM PDL STATION I/F CHECKS 232 *MIL (LOSS OF UHF TO THE VEHICLE WILL CCSE OCCUR.) 16-0112 *MIL NTD PDL STATION I/F CHECKS COMPLETE. | 232 | NTD *FLT | 232 CCSE | | 16-0113 CCSE NTD VERIFY ALL INTER-CENTER AND SUPPORT | 232 SITE COMMUNICATION NETWORK INTERFACE | NTD *GC CHECKS ARE COMPLETE, VALIDATED AND | *FLT CONFIGURED TO SUPPORT LAUNCH | *MIL COUNTDOWN. IMMEDIATELY REPORT ANY | GOIS NETWORK DISRUPTION TO NTD OR CCSE | UPON DETECTION. | 701 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ARMORED VEHICLE OPS ------------------- 16-0114 -03H30M NTD JFIR DISPATCH PAD RESCUE CREW FIRE 232 *SEC TO MAN ARMORED VEHICLE AT A/B-5 SU72723 R/B (FOR PAD A LAUNCH) OR A/B-4 R/B (FOR PAD B LAUNCH) AND STANDBY TO SUPPORT FINAL INSPECTION TEAM AND CLOSEOUT CREW INGRESS INTO PAD. VERIFY WHEN CREW AT APPROPRIATE ROADBLOCK FOR M113 COMM CHECKS. ESSENTIAL PERSONNEL ------------------- FIRE/RESCUE VEHICLES (3) FIRE/RESCUE ----------- JBOSC 14 702 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE PAD OIS ---------------- 16-0115 NTD STM ACTIVATE PAD OIS-D FOR FLIGHT COMM 232 CREW BOARDING AND FINAL SU72755 STM GYCC INSPECTION TEAM (5 MIN). 111 GYCC JYCD 117 16-0116 -03H25M JYCD GYCC OIS-D ACTIVATED TO PAD. COMM 117 GYCC STM 111 STM NTD 232 IUS RIMU CAL AND ALIGN (CONTINGENCY) | ------------------------------------ | | NOTE | | DO NOT PERFORM NEXT STEP | IF PRIMARY RIMU CAL AND ALIGN | (COMPLETED AT L-13H35M) WAS | ACCEPTABLE FOR LAUNCH. | | CONTINGENCY RIMU CAL AND | ALIGN WILL TAKE 2 HOURS | 10 MINUTES TO PERFORM AND | AN ADDITIONAL 30 MINUTES | TO EVALUATE ACCEPTABLE FOR | LAUNCH. | | PERFORM NEXT STEP 15 MINUTES | PRIOR TO LOX/LH2 STABLE | REPLENISH. | | 703 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0117 -03H20M ICTC PTC READY TO PROCEED WITH RIMU CAL AND | 134 ALIGN. REQUEST QUIET TIME BE PLACED | PTC NTD IN EFFECT IN 15 MINUTES. | 232 | NTD OTC | TBC | STM | | NOT PERFORMED ______| | NOTE | | FOLLOWING CRITERIA REQUIRED | FOR QUIET TIME ACTIVITY: | | 1. NO HYDRAULICALLY ACTUATED | AEROSURFACE OR SSME TVC | MOVEMENT | | 2. NO SRB NOZZLE MOVEMENT | | 3. NO MPS 17-INCH DISCONNECT | VALVE CYCLES | | 4. NO UNCOORDINATED CABIN | ACTIVITY | | 5. NO CHANGES IN PLB PURGE | (FLOW RATE OR TEMP) | | 6. NO 3,4,5,6,7 OR 9 VENT | DOOR OPERATIONS | | 7. NO SSME FRT OR OTHER | OPERATIONS RESULTING IN | SIMULATED SSME PNEUMATIC | SHUTDOWN. | | 8. MAX WIND OF 49 KNOTS | (PEAK VELOCITY IN ANY | DIRECTION). | | 9. NO MOBILE CRANE OPERATIONS | | 10. NO ORBITER WEATHER | PROTECTION MOVEMENT | | 11. NO ORBITER CRYOGENIC | CHILLDOWN | 704 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- | NOTE | | DO NOT PERFORM NEXT FOUR | STEPS IF PRIMARY RIMU CAL | AND ALIGN (COMPLETE AT | L-13H35M) WAS ACCEPTABLE | FOR LAUNCH. | | PERFORM THE NEXT STEP AFTER | LOX/LH2 STABILE REPLENISH. | | 16-0118 NTD PTC PROCEED WITH RIMU CAL AND ALIGN. | 232 QUIET TIME IN EFFECT. | | OMRSD P018JB.035-C | NOT PERFORMED ______| | NOTE | | DURING RIMU CAL/ALIGN, PTC | WILL REQUEST PAYLOAD BAY | PURGE, WIND DIRECTION AND | VELOCITY DATA EVERY 30 MIN. | PTC WILL RECORD THIS DATA | IN APPENDIX B (S0007VL4). | | 16-0119 PTC OTC PROVIDE TEMPERATURE, FLOWRATE AND | 132 HUMIDITY OF PAYLOAD BAY PURGE PER | OTC CPVD ORBITER OPERATION SUPPORT SETUP 15. | PTC WILL REQUEST DATA EVERY 30 MIN | DURING RIMU CAL/ALIGN. NOTIFY PTC | IMMEDIATELY OF ANY VIOLATIONS. | NOT PERFORMED ______| | 16-0120 PTC NTD REQUEST WIND DIRECTION AND VELOCITY | 232 READING FROM 60 FT WIND TOWERS. | NTD STM | STM JBDY RECORD: | 111 | JBDY *WEA WIND DIRECTION__________ | 231 | WIND VELOCITY__________ | 705 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IUS RIMU CAL AND ALIGN START | ---------------------------- | | 16-0121 PTC ICTC PROCEED WITH RIMU CAL AND ALIGN | 134 PER DOP D290-50020-27. QUIET TIME | IN EFFECT. REPORT STATUS OF CAL | AND ALIGN AS AVAILABLE. | | ARMORED VEHICLE COMM CHECK -------------------------- 16-0122 -03H15M NTD *HT1 PERFORM ARMORED VEHICLE COMM FIRE NET CHECK ON NET 105 WITH NTD. SU72724 105 16-0123 *HT1 NTD ARMORED VEHICLE COMM CHECK ON FIRE NET NET 105 COMPLETED. 105 FINAL INSPECTION TEAM AND CLOSEOUT ---------------------------------- CREW AT COMPLEX J ----------------- 16-0124 -03H15M OVCC OTC CLOSEOUT CREW ASSEMBLED AT SU72720 NET COMPLEX J. READY FOR PAD 105 ENTRY. OTC NTD 232 16-0125 -03H15M *FIT NTD FINAL INSPECTION TEAM AT COMPLEX SU72721 NET J AND READY FOR PAD ENTRY. 105 16-0126 -03H10M CLOX TBC LOX FAST FILL COMPLETE. NOW IN 136 TOPPING TO 100 PERCENT LEVEL. TBC NTD 232 706 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ANNOUNCE HOLD ------------- 16-0127 -03H10M NTD ALL CDC WILL HOLD AT T-03H00M. PA 232 CDC HOLD PREP ------------- 16-0128 -03H10M NTD CGLS SET CDC TO HOLD AT T-03H00M. 232 16-0129 CGLS HOME CMD KEY - PRESS CDTH - 0300/00 XMIT CMD KEY - PRESS 16-0130 CGLS NTD CDC SET TO HOLD AT T-03H00M. 232 START LH2 REPLENISH (S1004) --------------------------- 16-0131 -03H05M CLHY TBC ET LH2 TOPPING TO 100 PCT SU72710 136 COMPLETE. INITIATING REPLENISH TBC NTD OPERATIONS. 232 NTD STM STM JCFM 111 OMRSD S00FF0.082-1 LOX IN STABLE REPLENISH ----------------------- 16-0132 -03H05M CLOX TBC LOX IN STABLE REPLENISH. SU72700 136 TBC NTD 232 NTD STM LPS STM JCFM 111 707 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 IN STABLE REPLENISH (S1004) ------------------------------- 16-0133 -03H05M CLHY TBC LH2 IN STABLE REPLENISH MODE. SU72702 136 SU72799 TBC NTD 232 NTD STM LPS STM JCFM 111 OMRSD S00FF0.091-1 NOTE PERFORM NEXT STEP AFTER LOX AND LH2 IN STABLE REPLENISH. 16-0134 LPS C1MC PERFORM $FEPCPR, DEMAND UPDATE FOR 127 ALL FEPS PER OMI C2000. TERMINATE $FEPCPR AT COMPLETION OF DEMAND UPDATE. CONTROLLED SWITCHING IN EFFECT ------------------------------ 16-0135 -03H00M NTD *SCC LO2 AND LH2 TANKING IN STABILIZED 232 OTC REPLENISH MODE. CONTROLLED TBC SWITCHING IN EFFECT PTC STM 16-0136 JCFM STM CMDPS PRINTOUT COMPLETE. 111 708 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VARIABLE ASCENT PARAMETER U/L LOAD ---------------------------------- 16-0137 NTD *FLT PROCEED WITH TRANSMISSION OF 232 VARIABLE ASCENT PARAMETERS. RESET ORBITER VENT DOOR CMDS ---------------------------- 16-0138 -03H00M OTC CPVD RESET ORBITER VENT DOOR 132 COMMMANDS - OFF 16-0139 CPVD PERFORM FOLLOWING: 1. PRESS PFPK-7 VERIFY VAM01A AND VAM31A (ACTIVE) 2. PRESS PFPK-X NEXT TO VAM31A ONCE VERIFY PFP6 INDICATES "VENT DOOR" 3. PRESS PFPK-6 VERIFY PFP1 INDICATES "VENT CMD RESET" 4. PRESS PFPK-1 "VENT CMD RESET" ONCE CRT VERIFY MESSAGE "VENT CMD RESET" INDICATED 5. CRT VERIFY (AFTER APPROX 30 SEC. DELAY) MESSAGE "VENT CMD RESET COMPLETE" 6. PFPK7 - PRESS 16-0140 CPVD OTC ORBITER VENT DOOR COMMANDS 132 RESET - OFF 709 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MDM DISCRETE READ CHECK ----------------------- NOTE NOTED REQUIREMENT IS SATISFIED BY THE FOLLOWING STEPS. OMRS S00FE0.190-1R 16-0141 -03H00M OTC CDPS PERFORM T-3 HR BT4 SNAPSHOT SU72727 132 ON C/D FLIGHT CRITICAL AND PAYLOAD MDMS TO STATUS DISCRETE OUTPUTS 16-0142 -03H00M CDPS CURSOR CNTL (SAS01 PGB) DPS XMIT CURSOR KEY - PRESS MDM DISCRETE OUTPUT CHK (VAS94) XMIT CURSOR KEY - PRESS PFK 2 KEY - PRESS 16-0143 CDPS CURSOR CNTL (VAS94 PGB) T-3HR SNAPSHOT XMIT CURSOR KEY - PRESS NOTE PERFORM NEXT STEP UPON RECEIPT OF ORIGINAL COPY. 16-0144 -03H00M CDPS CONSOLE KYBD PFK-15 KEY - PRESS 16-0145 CDPS RETRIEVE BT4 ORIGINAL COPY WITH T-3HR MISCOMPARES FROM CONSOLE PRINTER. ANNOTATE PAGE NUMBERS ON COPY AND DELIVER TO DEV RUNNER. 710 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0146 CDPS OTC T-3HR SNAPSHOT ON C/D, FLT CRITICAL 132 AND PYLD MDMS COMPLETE. OTC CTPE 16-0147 CTPE BT4 TO BE DISTRIBUTED TO ALL SYSTEMS AS FOLLOWS C2 - 1 COPY FOR CNSE AND CCSE TO REVIEW C3/4 - 1 COPY FOR CMPS TO REVIEW C5/6 - 1 COPY FOR CPVD, CECL, CFCP, CPLE, CAFM TO REVIEW C7/8 - 1 COPY FOR COOS, CHYD AND CAPU TO REVIEW C9/10 - 1 COPY FOR CISL AND CEPD TO REVIEW C11/12 - 1 COPY FOR COFC, CGNC, CDPS AND CCME TO REVIEW INTG - 1 COPY FOR TPE TO REVIEW DEV RUNNER WILL PRODUCE 6 COPIES AND DISTRIBUTE. 16-0148 OTC ALL ALL SYSTEMS LISTED BELOW TO SU72727 132 REVIEW MDM DISCRETE OUTPUTS AND MISCOMPARES IN LISTING DELIVERED TO THEM. ALL MISCOMPARES MUST BE EVALUATED AND EXPLAINED. VERBAL OK ON MDM DISCRETE CONFIGURATION MUST BE RECEIVED FROM EACH SYSTEM BY END OF HOLD AT T-3 HOURS. TPE WILL ATTACH T-3 HOUR MISCOMPARE TO THIS OMI. CPLE _____ CAPU _____ CCSE _____ CISL _____ CAFM _____ CEPD _____ CMPS _____ CGNC _____ CECL _____ COFC _____ CPVD _____ CCME _____ CFCP _____ CDPS _____ COOS _____ CHYD _____ 16-0149 NOTED REQUIREMENT COMPLETE. OMRSD S00FE0.190-1R (VAS94) 711 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CRT COUNTDOWN TIMER SETUP ------------------------- 16-0150 -03H00M OTC CDPS SETUP ONBOARD COUNTDOWN TIMER. SU72726 132 16-0151 CDPS CONSOLE KYBD DEUE DEST GNC 1 LDBA XMIT CMD KEY - PRESS DEUE SPEC 2 PRO XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS CRT (VAS59 PG B) DEU 1 DISP ID 0020 NOTE ANTICIPATED GMT OF LIFTOFF WILL BE ENTERED IN NEXT STEP. 16-0152 CDPS CONSOLE KYBD DEUE ITEM 17 +__ +__ +__ EXEC HH MM SS XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS DEUE RESUME XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS 16-0153 CDPS OTC CRT COUNTDOWN TIMER SETUP COMPLETE. 132 712 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAVS DELIVERY COMPLETE ---------------------- 16-0154 -03H00M *SCB JSTC 1 EA PORTABLE AIR VENTILATOR LS NET PER FLIGHT CREW MEMBER PLUS ONE SU72747 104 DELIVERED TO O&C CUL-DE-SAC, JSTC STM ASTRONAUT CREW VAN. 111 1 EA PORTABLE AIR VENTILATOR PER FLIGHT CREW MEMBER DELIVERED TO FIRE STATION NO. 2 FOR ASTRONAUT CLOSEOUT CREW. ***T-3H00M HOLD*** ------------------ 16-0155 -03H00M NTD CDC HOLDING AT T-03H00M. (HOLDING) PA 232 16-0156 LPS C2MC STRIP, LABEL PLOTS, AND INSTALL NEW TAKE UP ROLLS ON ALL PP1 AND PP2 UNITS. NOTE PERFORM NEXT STEP AFTER CDC IS HOLDING. 16-0157 -03H00M CGLS HOME CMD KEY - PRESS (HOLDING) CDTC ____/__.000 HHMM SS XMIT CMD KEY - PRESS 16-0158 -03H00M *PAC NTD *PAC FULLY MANNED. READY TO SU72732 (HOLDING) 232 SUPPORT PAD ENTRY/FLIGHT CREW INGRESS. 713 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF FOD DOCUMENTED IN APPENDIX M. 16-0159 PSTM STM FOD DOCUMENTED IN APPENDIX M HAS 111 BEEN DISPOSITIONED AND IS NOT A STM NTD CONSTRAINT TO LAUNCH. 232 SPE NTD NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF SRBTS INSTALLED FOR THIS FLIGHT AND LAUNCH IS FROM PAD A. 16-0160 SRO NTD FCA VAN DEPARTING FOR UCS 15 TO 232 SUPPORT SRBTS CHECKOUT. NTD *SEC NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF SRBTS INSTALLED FOR THIS FLIGHT AND LAUNCH IS FROM PAD B. 16-0161 SRO NTD FCA VAN AT GATE 6-T ENROUTE TO UCS-4 232 TO SUPPORT SRBTS CHECKOUT. REQUEST NTD *SEC SECURITY ALLOW FCA VAN ACCESS THROUGH GATES 6T AND 6. NOT PERFORMED ______ 714 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FIRING ROOM CONFIGURATION FOR PAD --------------------------------- ENTRY ----- 16-0162 -03H00M NTD OTC IMPLEMENT AND VERIFY FOLLOWING (HOLDING) 232 TBC CONFIGURATIONS DURING TOTAL TIME STM PERSONNEL INSIDE BDA: PTC 1. NO LPS TEST PROGRAM AUTHORIZED EXCEPT THOSE REQUIRED TO MONITOR AND MAINTAIN VEHICLE AND GSE IN SAFE CONFIGURATION. 2. CONTROL SWITCHING IN EFFECT. 3. PICS AND S&A DEVICES NOT ARMED. 4. VEHICLE AND GSE HAZ GAS DETECTION SYSTEM OPERATING AND INDICATING SAFE CONDITION. 5. ADVISE NTD OF ANY HAZARDOUS GAS DETECTION SYS UNSAFE INDICATIONS. 715 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0163 -03H00M NTD *SCC REQUEST SAFETY CONCURRENCE TO CLEAR (HOLDING) 232 CLOSEOUT CREW, FINAL INSPECTION TEAM *SCC *PSE AND M113 BUNKER CREW INTO PAD. VERIFY NET CREWS DRESSED IN NON-STATIC PRODUCING, 105 FLAME RETARDANT COVERALLS AND HAVE BREATHING AIR AVAILABLE. ESSENTIAL PERSONNEL IN CLOSEOUT CREW ------------------------------------ CLOSEOUT CREW LEADER (1) ASP (2)* SUIT TECH (1) NASA QUALITY CONTROL (1) ORB MECH TECHS (2) *SECOND ASP WILL GO TO PAD TO ASSIST WITH CREW COMPARTMENT ACTIVITIES IF: 1. CREW COMPARTMENT WAS UNABLE TO BE CONFIGURED FOR FLIGHT CREW ARRIVAL PRIOR TO CLEARING FOR ET LOAD AND 2. THERE IS NOT SUFFICIENT TIME AVAILABLE AFTER ET LOAD FOR ONE ASP TO COMPLETE CONFIGURATION PRIOR TO CREW INGRESS. SECOND ASP WILL ACCOMPANY CLOSEOUT CREW TO PAD AND WILL DEPART PAD IN ASTROVAN WHEN FLIGHT CREW ARRIVES. 716 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0163 CLOSEOUT CREW VEHICLES - 2 CON'T -------------------------- ESSENTIAL PERSONNEL FOR FINAL ----------------------------- INSPECTION ---------- (SSV,FSS,MLP) ET NASA SFOC -- ---- ---- ENGR 1 4 2 SAF 1 FINAL INSPECTION TEAM VEHICLES - 2 ---------------------------------- ESSENTIAL PERSONNEL AT BUNKER ----------------------------- PAD RESCUE (3) PAD RESCUE VEHICLES - 1 ------------------------ NOTE PERFORM NEXT TWO STEPS IF SECOND ASP REQUIRED AT PAD FOR CREW COMPARTMENT CONFIGURATION. 16-0164 VIT NTD REQUEST CONCURRENCE FOR SECOND ASP 232 TO ACCOMPANY CLOSEOUT CREW TO PAD NTD *SCC TO SUPPORT CREW COMPARMENT *SCC *PSE CONFIGURATION. NET 105 NOT PERFORMED ______ 16-0165 *PSE *SCC YOU HAVE SAFETY CONCURRENCE FOR NET SECOND ASP TO ACCOMPANY CLOSEOUT 105 CREW TO PAD. *SCC NTD 232 NTD VIT NOT PERFORMED ______ 717 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0166 -03H00M *PSE *SCC CLOSEOUT CREW AND FINAL INSPECTION (HOLDING) NET TEAM PROPERLY ATTIRED AND CLEAR 105 TO PROCEED WITH PAD RESCUE MEMBERS *SCC NTD TO LAUNCH PAD. 232 16-0167 NTD *SEC CLEAR CLOSEOUT CREW AND FINAL SEC 232 INSPECTION TEAM THROUGH ROADBLOCK A/B-11 FOR INGRESS TO PAD. 16-0168 NTD STM PROVIDE VIDEO TRACKING AND COMM 232 RECORDING OF CLOSEOUT CREW, AND STM JYVO FINAL INSPECTION TEAM FROM A/B-11 138 ROADBLOCK TO PAD (SEE JYVO FIGURE 4), AND ARMORED VEHICLE BUNKER CREW FROM A/B-5 (PAD A) A/B-4 (PAB B). 16-0169 STM JYVR START VIDEO RECORDING OF OTV COMM 138 CAMERA 073/173 (SEE STM FIGURE 4). 16-0170 NTD OTC PROCEED TO LAUNCH PAD FOR CLOSEOUT 232 OPERATIONS AND REPORT IN ON OIS CH 132. OTC OVCC VERIFY AUTHORIZED PERSONNEL HAVE NET COMBINATION FOR WINDOW COVER REMOVAL 105 (IF INSTALLED). WARNING ALL FINAL INSPECTION TEAM PERSONNEL WILL REMAIN FURTHER THAN 6 FEET FROM UNPROTECTED EDGES ON MLP ZERO LEVEL. 16-0171 NTD *FIT PERFORM FINAL INSPECTION PER SU72729 NET S0007VL4 (SEQ 57) AND OMI S6444. 105 OMRS S00U00.020-A-1 OMRS S00U00.020-C-1 OMRS S00U00.020-D-1 16-0172 NTD *PAC FINAL INSPECTION TEAM AND SU72748 232 CLOSEOUT CREW RELEASED AND PROCEEDING TO PAD. 718 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0173 NTD *SEC SEND PAD RESCUE PERSONNEL TO FIRE 232 JFIR ARMORED VEHICLE AT SLIDEWIRE SEC JFIR *PRL BUNKER FOR CLOSEOUT CREW AND SU72756 NET FINAL INSPECTION TEAM ENTRY. 105 RESCUE CREW TO REMAIN IN BUNKER UNTIL CLOSEOUT CREW EGRESSES PAD. 16-0174 -03H00M OVCC OTC CLOSEOUT CREW APPROACHING SU72725 (HOLDING) NET ELEVATOR. REQUEST PERMISSION TO 105 PROCEED TO WHITE ROOM. OTC NTD 232 16-0175 NTD STM VERIFY O2 CONCENTRATION IN WHITE PWRA | 232 ROOM ACCEPTABLE FOR CREW INGRESS. STM JBEP 111 CLOSEOUT CREW TO WHITE ROOM --------------------------- NOTE PERFORM NEXT TWO STEPS IF FIXED O2 METER IN WHITE ROOM CAN VERIFY 02 CONCENTRATION ACCEPTABLE. 16-0176 JBEP STM O2 CONCENTRATION ACCEPTABLE IN PWRA | 111 WHITE ROOM. STM NTD 232 NOT PERFORMED ______ 16-0177 NTD OTC OVCC REPORT TO WHITE ROOM AND REPORT 232 IN ON OIS CH 132. OTC OVCC NET 105 NOT PERFORMED ______ 719 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT TWO STEPS IF O2 CONCENTRATION CANNOT BE VERIFIED ACCEPTABLE BY FIXED 02 METER IN WHITE ROOM. 16-0178 JBEP STM O2 CONCENTRATION IN WHITE ROOM PWRA | 111 CANNOT BE VERIFIED ACCEPTABLE STM NTD BY FIXED O2 MONITORING SYSTEM. 232 NOT PERFORMED ______ 16-0179 NTD OTC HAVE OVCC PROCEED TO WHITE ROOM 232 AND PERFORM O2 CONCENTRATION CHECK OTC OVCC PRIOR TO WHITE ROOM ENTRY. NET REPORT IN ON OIS CH 132. 105 NOT PERFORMED ______ OPEN ORBITER LEEWARD VENT DOORS ------------------------------- 1 AND 2 (CONTINGENCY) --------------------- NOTE IF O2 CONCENTRATION IN OAA WHITE ROOM BECOMES LESS THAN 20 PCT AS INDICATED ON W/R O2 METER (OTV CAM 005/105), PERFORM NEXT THREE STEPS TO OPEN LEEWARD VENT DOORS 1&2. 16-0180 -07H15M NTD OTC O2 CONCENTRATION WITHIN WHITE SU72539 232 ROOM LESS THAN 20 PCT, OPEN OTC CPVD ORBITER VENT DOORS 1 AND 2 ON 132 LEEWARD SIDE. NOT PERFORMED ______ 16-0181 CPVD CURSOR CNTL (VAM31A/VAM09A) VENT DOORS 1&2 (LEEWARD) OPEN TARGET XMIT CURSOR NOT PERFORMED ______ 720 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0182 CPVD OTC LEEWARD VENT DOOR OPENING COMPLETE. 132 OTC NTD 232 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF O2 CONCENTRATION IN WHITE ROOM STILL LESS THAN 20 PCT AFTER PVD OPENED LEEWARD VENT DOORS. 16-0183 OTC *FCM WHITE ROOM 132 1. EXHAUST FAN SW - ON 2. POSITION REAR SWINGING DOORS IN OPEN POSITION AND SECURE. NOT PERFORMED ______ NOTE IF PREVIOUS FOUR STEPS DO NOT SOLVE LESS THAN 20 PCT O2 CONCENTRATION PROBLEM, PERFORM NEXT FOUR STEPS TO OPEN WINDWARD VENT DOORS 1 AND 2 ONLY IF WIND CONDITION IS LESS THAN 18 KTS AND NO RAIN EXPECTED. REF OMRS V05AG0.060 16-0184 NTD *FLT WINDWARD VENT DOORS 1 AND 2 232 WILL BE OPENED. NOT PERFORMED ______ 16-0185 NTD OTC OPEN WINDWARD VENT DOORS 1 AND 2. 232 OTC CPVD 132 NOT PERFORMED ______ 721 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0186 CPVD CURSOR CNTL (VAM31A/VAM09A) VENT DOORS 1 AND 2 (WINDWARD) OPEN TARGET XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 16-0187 CPVD OTC WINDWARD VENT DOOR OPENING 132 COMPLETE. OTC NTD 232 NTD *SCC NOT PERFORMED ______ NOTE PERFORM NEXT TWO STEPS IF WHITE ROOM O2 INDICATIONS LESS THAN 19.5 PCT. 16-0188 NTD OTC PERFORM INTERIOR O2 LEVEL CHECKS 232 *SCC PRIOR TO WHITE ROOM/CREW MODULE OTC OVCC ENTRY. 132 NOT PERFORMED ______ 16-0189 OVCC OTC O2 LEVEL CHECK IN WHITE ROOM/CREW 132 MODULE ACCEPTABLE. VERIFY SAFETY OTC NTD CONCURRENCE FOR PERSONNEL ENTRY. 232 NTD *SCC NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF EXHAUST FAN IS ON AND REAR SWINGING DOORS OPEN TO WHITE ROOM. 16-0190 OTC OVCC WHITE ROOM 132 1. EXHAUST FAN SW - OFF 2. CLOSE REAR SWINGING DOORS T:______ NOT PERFORMED ______ 722 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0191 OVCC OTC CLOSEOUT CREW READY TO ENTER 132 ORBITER. 16-0192 CECL OTC PARTIAL PRESSURE OF OXYGEN IN CREW 132 COMPARTMENT SATISFACTORY. 16-0193 OTC OVCC PERFORM O2 LEVEL CHECK PRIOR 132 TO CABIN ENTRY. 16-0194 OVCC OTC O2 LEVEL CHECK IN CABIN/WHITE SU72725 132 ROOM ACCEPTABLE FOR CREW INGRESS. OTC NTD 232 WARNING DUE TO GN2 BUILDUP AROUND ORBITER HATCH, PERSONNEL SHALL NOT LINGER IN HATCH OPENING. 16-0195 NTD OTC PROCEED WITH INGRESS OF CREW 232 COMPARTMENT. PROVIDE TWO UNWRAPPED OTC OVCC ELSA'S FOR ASP AND NST. 132 16-0196 OVCC OTC ASP AND NST ENTERING CREW MODULE SU72728 132 AT THIS TIME. 16-0197 -03H00M NTD STM STOP VIDEO TRACK AND RECORDING COMM (HOLDING) 232 OF CLOSEOUT CREW (SEE JYVO FIG 4). STM JYVO 138 JYVR WX SATELLITE PHOTO ------------------ NOTE PERFORM NEXT STEP 1 HOUR PRIOR TO SCHEDULED WEATHER BRIEFING. 16-0198 -03H00M NTD STM VERIFY FULL DISC WEATHER SU72753 (HOLDING) 232 SATELLITE PHOTO HAS BEEN EMAILED | STM *WEA TO ASTRONAUT CREW QUARTERS | 231 (THOMAS.W.KWIATKOWSKI1@JSC.NASA.GOV). | 723 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GO FOR FLIGHT CREW WAKE-UP -------------------------- 16-0199 -03H00M VIT NTD VERIFY GO FOR CREW WAKE-UP. (HOLDING) 7-3901 (RECORDED PHONE) (FR1) 7-3903 (RECORDED PHONE) (FR3) 16-0200 VIT NTD VERIFY CREW EGRESS SYSTEM SATISFACTORY. 16-0201 NTD OTC CREW WAKE UP STARTING. 232 CONFIG COMM ----------- 16-0202 -03H00M ASP PANEL A15 (HOLDING) DON COMM HEADSET PREVIOUSLY CONNECTED. ASP PANEL MO42F MIDDECK SPEAKER AUDIO SPKR PWR SW - OFF ASP PS COMM CCU PWR SW - ON CONFIG COMM (CONTINGENCY) ------------------------- NOTE PERFORM NEXT SEVEN STEPS ONLY IN SUPPORT OF A 24 HOUR SCRUB TURNAROUND OPERATION. 16-0203 -03H00M OTC CCSE PROCEED WITH CONFIG OF COMM (HOLDING) 132 ON OIS CH 214 (CONTINGENCY). NTD *MIL 232 NOT PERFORMED ______ 16-0204 -03H00M CCSE *MIL CONFIGURE FOR S-BAND AND UHF (HOLDING) ASTRO COMM. NOT PERFORMED ______ 724 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ASTRO COMM PANEL ACTIVATION --------------------------- NOTE FOLLOWING PBI'S WHICH ARE ALREADY ON WILL HAVE TO BE CYCLED TO OFF THEN BACK TO ON. 16-0205 -03H00M CCSE OTC ASTRO COMM (HOLDING) 132 OIS INTERFACE PANEL 1. PWR SW - ON 2. ICOM-A SW - ACTIVE 3. ICOM-B SW - ACTIVE 4. A/G 1 SW - ACTIVE 5. A/G 2 SW - ACTIVE 6. UHF SW - ACTIVE 7. VERIFY ABOVE ACTIVE LITES ARE ON NOT PERFORMED ______ 16-0206 -03H00M CCSE PERFORM TWO-WAY COMM CHECKS WITH (HOLDING) ASP ON: OIS 214 (ICOM A) OIS 215 (ICOM B) 212 (A/G 1) 213 (A/G 2) OIS 6311 (FR1-A/A) OR 6331 (FR3-A/A) NOT PERFORMED ______ 16-0207 OTC PERFORM VOICE CHECKS WITH ASP ON AB4 AUDIO - (A/G 1, A/G 2, UMB A & UMB B) NOT PERFORMED ______ 725 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0208 -03H00M CCSE OTC ASTRO COMM (HOLDING) 132 OIS INTERFACE PANEL 1. ICOM-A SW - OFF 2. ICOM-B SW - OFF 3. VERIFY ABOVE ACTIVE LITES OFF 4. A/G 2 SW - MONITOR 5. VERIFY MONITOR A/G 2 LITE ON NOT PERFORMED ______ 16-0209 CCSE OTC CONFIG COMM (CONTINGENCY) COMPLETE. 132 OTC NTD 232 NOT PERFORMED ______ CONFIG COMM (CONTINGENCY) COMPLETE ---------------------------------- ASP COMM CHECK -------------- 16-0210 -03H00M ASP OTC PERFORM COMM CHECK WITH OTC ON SU72739 (HOLDING) 212 A/G 1 (OIS CH 212), A/G 2 (OIS 6313/6333) AND A/A (OIS 6311/6331). SIMO A/G A/A DELAY ADJUSTMENT ----------------------------- 16-0211 OTC ASP STANDBY TO PERFORM SIMO A/G-1, A/G-2 AND A/A VOICE CHECKS FOR DELAY ADJUSTMENTS. 16-0212 OTC NTD READY FOR SIMO A/G-1, A/G-2 AND 232 A/A VOICE CHECKS FOR DELAY NTD *FLT ADJUSTMENTS. USE LONG TEST ASP COUNT. DURING COUNT HOUSTON COMM TECH WILL ADJUST DELAY BETWEEN A/G AND A/A PER ASP DIRECTION. REPEAT AS REQUIRED. 726 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0213 *FLT RECORD INSERTED DELAY U/L __________ D/L __________ 16-0214 NTD OTC SIMO A/G, A/A DELAY ADJUSTMENT 232 ASP COMPLETE. ER HOLDFIRE TEST ---------------- 16-0215 NTD SRO PERFORM RANGE SAFETY SYSTEM SU72704 232 TBC HOLDFIRE CHECKS ON OIS CH 175. TBC CBRS 136 16-0216 CBRS SRSS HOLDFIRE PANEL S1 - LAUNCH PROCEED S2 - OFF CBRS SRSS HOLDFIRE PANEL UPPER/LOWER LAUNCH PROCEED - GREEN UPPER/LOWER HOLD - OFF UPPER/LOWER AFETR HOLD - OFF 16-0217 CBRS SFCO SFCO PANEL PROCEED/HOLD SW - HOLD 16-0218 CBRS SFCO VERIFY HOLD INDICATION FCO SRO CBRS 16-0219 CBRS SFCO SFCO PANEL PROCEED/HOLD SW - PROCEED 16-0220 CBRS SFCO VERIFY PROCEED INDICATION FCO SRO CBRS 16-0221 CBRS FCO FCO PANEL PROCEED/HOLD SW - HOLD 727 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0222 CBRS SFCO VERIFY HOLD INDICATION FCO SRO CBRS 16-0223 CBRS FCO FCO PANEL PROCEED/HOLD SW - PROCEED 16-0224 CBRS SFCO VERIFY PROCEED INDICATION FCO SRO CBRS 16-0225 CBRS SRO SRO PANEL PROCEED/HOLD SW - HOLD 16-0226 CBRS SFCO VERIFY HOLD INDICATION FCO SRO CBRS 16-0227 CBRS SRO SRO PANEL PROCEED/HOLD SW - PROCEED 16-0228 CBRS SFCO VERIFY PROCEED INDICATION FCO SRO CBRS 16-0229 CBRS SRSS HOLDFIRE PANEL PROCEED/HOLD SW - HOLD 16-0230 CBRS SFCO VERIFY HOLD INDICATION FCO SRO CBRS 16-0231 CBRS SRSS HOLDFIRE PANEL PROCEED/HOLD SW - PROCEED 16-0232 CBRS SFCO VERIFY PROCEED INDICATION FCO SRO CBRS 16-0233 CBRS SRSS HOLDFIRE PANEL S2 - BYPASS 728 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0234 CBRS SRO RANGE SAFETY HOLDFIRE CHECKS SU72704 175 COMPLETE. SRO NTD 232 FCO ABORT ADVISORY CHECKS ------------------------- 16-0235 NTD OTC STANDBY FOR FCO ABORT ADVISORY SU72740 232 *FLT CHECKS ON OIS CH 212. OTC ASP 132 CISL 16-0236 NTD *FLT VERIFY SYSTEM ARMED AND READY TO 232 SRO PERFORM CHECK ON OIS CH 212. 16-0237 NTD SRO PERFORM FCO ABORT ADVISORY CHECKS. 232 NOTE FOLLOWING STEPS VERIFY THE ROCC FLIGHT CONTROL CONSOLE. ASP WILL REPORT ABORT LIGHT ON OR OFF REGARDLESS OF LIGHT INTENSITY. 16-0238 FCO TRANSMIT DSM 4054 (ABORT A/B ON) VIA FCO CONSOLE LEFT HARDWARE PBI. 16-0239 ASP PANEL F6 ABORT INDICATOR LIGHT ON 16-0240 FLT TRANSMIT BOTH DSM 4051 (ABORT A OFF) AND DSM 4053 (ABORT B OFF). 16-0241 ASP PANEL F6 ABORT INDICATOR LIGHT OFF 16-0242 FLT TRANSMIT DSM 4054 (ABORT A/B ON) VIA FCO CONSOLE RIGHT HARDWARE PBI. 16-0243 ASP PANEL F6 ABORT INDICATOR LIGHT ON 16-0244 FLT TRANSMIT BOTH DSM 4051 (ABORT A OFF) AND DSM 4053 (ABORT B OFF). 729 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0245 ASP PANEL F6 ABORT INDICATOR LIGHT OFF 16-0246 SRO NTD FCO ABORT ADVISORY CHECKS SU72740 232 *FLT COMPLETE. SWITCH OIS CMD CH (ORBITER) --------------------------- 16-0247 -03H00M NTD OTC ALL ORBITER TEST TEAM PERSONNEL (HOLDING) 232 SWITCH TO CMD CH 212 ACTIVE. 16-0248 OTC ALL ALL ORBITER PERSONNEL SWITCH TO SU72735 132 COMMAND CH 212 AND STANDBY FOR COMM CHECK. CONTINUE TO SIDETONE CH 132 FOR DURATION OF COUNT. ORBITER OIS COMM CHECK ---------------------- 16-0249 -03H00M OTC PERFORM COMM CHECK ON OIS CH 212. (HOLDING) 212 CPLE _____ CEPD _____ CCSE _____ CGNC _____ CNSE _____ COFC _____ CAFM _____ CCME _____ CMPL _____ CODS _____ CMPS _____ CDPS _____ CSME _____ CVFS _____ CECL _____ CGLS _____ CPVD _____ CTPE _____ CFCP _____ CMQC _____ CGSS _____ OVCC _____ COOS _____ CHYD _____ CAPU _____ CHGD _____ CISL _____ 730 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF PAYLOAD HAS ACTIVE LCC. PAYLOAD COMM CHECKS ------------------- 16-0250 NTD PTC PERFORM A/G-1 COMM CHECKS WITH 232 PAYLOAD LAUNCH TEAM ON OIS CH 212. PTC ICC1 | ICTC | AXTC | NOT PERFORMED ______ | T-0 GMT VERIFICATION FOR IUS | ---------------------------- | | NOTE | | PERFORM THE NEXT TWO STEPS | FOR IUS MISSION (STS-93). | | 16-0251 -03H00M PTC NTD REQUEST T-0 GMT FOR IUS SYSTEM. | (HOLDING) 232 | | RECORD: | | T-0 GMT __________ | | NOT PERFORMED ______| | 16-0252 PTC ICTC RECORD PRESENT T-0 GMT __________. | 134 | NOT PERFORMED ______| | 731 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONFIG AND INSPECT CM FOR INGRESS --------------------------------- 16-0253 -03H00M OTC ASP CONFIGURE AND INSPECT CREW SU72730 (HOLDING) 212 NST MODULE. REPORT WHEN READY FOR CREW INGRESS. 16-0254 ASP INSPECT AND PREPARE SEATS FOR NST FLIGHT CREW INGRESS. REMOVE FROM CREW MODULE ANY ITEMS NOT REQUIRED FOR CREW INGRESS AND CREW MODULE CLOSEOUT. 732 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF DUAL MODE COOLING IF ACTIVE. 16-0255 OTC CECL CONFIGURE FREON LOOPS TO BYPASS SU72734 212 FLOW PER ORBITER OPERATION SUPPORT SETUP 8. REPORT COMPLETION. NOT PERFORMED ______ FUEL CELL WATER LINE VERIF -------------------------- 16-0256 CFCP CRT (VWR05) VERIFY WATER TANK QUANTITY INCREASE CONSISTENT WITH CALCULATED FUEL CELL WATER PRODUCTION (+/- 10 PCT OF CALCULATED DELTA QUANTITY). OMRSD V62AG0.050-1R (VWR05) 733 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- POT/SUPPLY WATER QTY ADJ ------------------------- NOTE PERFORM NEXT TWO STEPS IF REQUIRED TO ENSURE TARGETED LIFTOFF TK-A QUANTITY WILL BE MET PER OMRS TABLE V62AE0.030. 16-0257 -03H00M OTC CFCP PERFORM POT/SUPPLY WATER TK-A SU72731 (HOLDING) 212 ASP DRAIN PER S0007VL4 (SEQ 54 OMTO OPTION D) ON OIS CH 153. NOT PERFORMED ______ 16-0258 CFCP OTC POT/SUPPLY WATER TK-A DRAIN COMPLETE. NOT PERFORMED ______ 16-0259 OTC CFCP VERIFY CORRECT ULLAGE TO ACCEPT SU72731 212 FUEL CELL WATER FROM T-0 THRU END OF LAUNCH WINDOW TO MEET LIFT-OFF POTABLE H2O TANK QUANTITIES PER OMRS TABLE V62AE0.030 FOR THIS MISSION. OMRSD V62AG0.010-D-1R 16-0260 CFCP ASP PANEL ML26C (VERIFY OR POSITION) SUPPLY H2O TK A SUPPLY VALVE - CLOSE (DWN) TK VENT - VENT (DWN) IMU PREFLIGHT CALIBRATION COMPLETE ---------------------------------- 16-0261 -03H00M CGNC OTC IMU PREFLIGHT CALIBRATION SU72717 (HOLDING) 212 COMPLETE. 734 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE FOLLOWING STEP WILL TAKE A FINAL BACKGROUND CHECK OF BOTH THE PAYLOAD BAY AND THE MIDBODY. THE FOLLOWING STEP WILL SAMPLE ZERO GAS, MIDBODY, ZERO GAS, PAYLOAD BAY, ZERO GAS FOR A MINIMUM OF 30 DATA POINTS PER SAMPLE SELECTION. (TEST TIME IS APPROXIMATELY 1 HOUR) 16-0262 OTC CHGD PERFORM FINAL PRSD SYSTEM BACKGROUND 132 CHECK. RECORD RESULTS AS FOLLOWS: INITIAL MIDBODY O2:_____PPM PURGE CIRCUIT 2 R/H:____% INITIAL ZERO: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ MIDBODY: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ MIDDLE ZERO: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ PAYLOAD BAY: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ MIDDLE ZERO: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ PRSD TEST: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ FINAL ZERO: H2:____PPM O2:____PPM STD DEV: H2:___ O2:___ FINAL MIDBODY O2:_____PPM 735 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- INITIATE IMU ATT DET AND PFA ---------------------------- AUTO SEQUENCE ------------- NOTE NEXT TWO STEPS WILL INITIATE AN AUTO SEQUENCE START FOR THE FOLLOWING; IMU PPOS AT T-2H04M IMU ATT DET AT T-1H57M IMU PFA AT T-1H47M PFK 14B (VABM1/VWB19) WILL DE-ACTIVATE AUTO SEQUENCE. PFK 14B IS AVAILABLE ANYTIME AFTER AUTO SEQUENCE IS ACTIVATED. THESE STEPS SHALL BE PERFORMED ANY TIME AFTER PREFLIGHT CAL, BUT PRIOR TO T-2H06M 16-0263 CGNC APPL PAGE (VABM1/VWB19 PG A) PFK 4 KEY - PRESS (DISK FILES SECT 4) PFK 8 KEY - PRESS (CLEAR DISK FILE SECTOR) PRK 9 KEY - PRESS (INHIBIT WRITE/ CLEAR PAGE) 16-0264 CGNC CURSOR CNTL (VABM1/VWB19 PG B) ATT DET/PFA AUTO SEQ XMIT CURSOR KEY - PRESS 736 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ECP AI MODE 1: MATCH CMDS TO POSN ---------------------------------- NOTE PERFORM NEXT 11 STEPS AFTER IMU PREFLIGHT CAL IS COMPLETE AND BEFORE IMU PREFLIGHT CONTINGENCY CAL OR GYROCOMPASS ALIGN IS STARTED. 16-0265 COFC PFP (SAB20/SWB02) PFPK (SWB02) - PRESS 16-0266 COFC PFP (SWB02) PFPK4 (ORB/SRB AI MODE 1) - PRESS OMRSD S00FE0.210 737 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SET NWS CMDS TO 0 DEG --------------------- NOTE FOLLOWING STEP SETS NWS1 AND NWS2 CMDS TO 0 DEG (-0.44 VOLTS). ANY SUBSEQUENT AI MODE 1 WITH SRB WILL RESET CMDS BACK TO 1 DEG (0 VOLTS). 16-0267 COFC CONSOLE KYBD GPCC RFG XMIT CMD KEY - PRESS CURSOR CNTL (RFG ECP) SLOPE VALUE: 2 XMIT CURSOR KEY - PRESS CURSOR CNTL ACT/RGA ID: 0 XMIT CURSOR KEY - PRESS CURSOR CNTL FINAL VALUE: -44 CNTS * XMIT CURSOR KEY - PRESS PFK-1 KEY - PRESS (EXECUTE RFG) *NULL=-44 CNTS =-0.44 VDC = 0 DEG NOTE PERFORM NEXT SEVEN STEPS IF MPS TVC ACTUATOR 2P OR 3P COMMAND IS GREATER THAN +8.0 DEG. 16-0268 COFC CURSOR CNTL (SAB19/SWB01 PG B) ATVC - OPS MAN XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 738 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0269 COFC CURSOR CNTL (SAB22/VWB35 PG B) MANUAL POSITIONING XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 16-0270 COFC CURSOR CNTL (SAB22/SSB09 PGB) ECP MODE SELECT - RFG XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 16-0271 COFC APPL PG B (SAB22/SSB09) CURSOR CNTL ME 2P - ACT SELECT XMIT CURSOR KEY - PRESS CONSOLE KYBD ENTER 6.0 (BANK TELLER MODE) PFK1 - PRESS (START RFG) NOT PERFORMED ______ 16-0272 COFC APPL PG (SAB22/SSB09) CURSOR CNTL ME 3P - ACT SELECT XMIT CURSOR KEY - PRESS CONSOLE KYBD ENTER 6.0 (BANK TELLER MODE) PFK1 - PRESS (START RFG) NOT PERFORMED ______ 16-0273 COFC CURSOR CNTL (SAB22/SSB09 PG B) ECP MODE SELECT - TERMINATE XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 16-0274 COFC APPL PG (SAB22/VWB35 PG B) PFK15 KEY - PRESS (TERM SAB22) NOT PERFORMED ______ 739 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF MAIN ENGINE 1 YAW DRIFT FROM OPS 101 TRANSITION POSITION OF +0.2 DEG APPROACHS A DELTA OF 2.0 DEG. 16-0275 COFC CONSOLE KYBD (M.E. 1 YAW) APPLY V58K1168CL 0.2 XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS REPEAT FOR: V58K1169CL V58K1170CL V58K1171CL NOT PERFORMED ______ IMU PREFLIGHT CAL (CONTINGENCY) ------------------------------- NOTE PERFORM NEXT STEP IF INITIAL IMU PREFLIGHT CALIBRATION FAILED. 16-0276 -03H00M OTC CGNC PERFORM IMU PREFLIGHT SU72714 (HOLDING) 212 CALIBRATION PER OMI V1123. (2 HR 45 MIN). RT OMI LOG NO.__________ NOT PERFORMED ______ 740 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IMU POST CAL GYROCOMPASS ALIGN ------------------------------ NOTE PERFORM NEXT STEP IF INITIAL IMU PREFLIGHT CALIBRATION PASSED. 16-0277 -03H00M OTC CGNC PERFORM IMU GYROCOMPASS ALIGN SU72716 (HOLDING) 212 PER OMI V1123 (42 MIN). RT OMI LOG NO.__________ NOT PERFORMED ______ 16-0278 TBC OTC REQUEST SFOC QUALITY TO SUPPORT 212 SRSS FLIGHT CODE INSERTION. OTC RCRE NOTE PERFORM NEXT STEP IF SRBTS INSTALLED FOR THIS FLIGHT. 16-0279 -03H00M SRO NTD FCA VAN ON STATION. (HOLDING) 232 NOT PERFORMED ______ ER OPEN LOOP CHECKS ------------------- 16-0280 NTD OTC SUPPORT ER OPEN LOOP CHECKS ON SU72706 232 OIS CH 175 AND PERFORM FOLLOWING OTC RCRT PREPS. 132 RCRT RACK 8234 PANEL A2 (VCR) - RECORD PANEL A3 (VCR) - RECORD PANEL A5 (STRIP CHART) - START (STRIPCHART CAN BE STOPPED AFTER ER CHECKS, VCR'S REMAIN IN RECORD) T:______ 741 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0281 -03H00M NTD SRO PERFORM ER OPEN LOOP CHECK (HOLDING) 232 WITH OPF AND XMTR SITE PER ER A2811 ON OIS CH 175. KSC PERSONNEL READY TO SUPPORT. ER OPEN LOOP CHECK COMPLETE --------------------------- 16-0282 -03H00M SRO NTD ER "OPEN LOOP CHECK" COMPLETE. (HOLDING) 232 NOTE PERFORM NEXT STEP IF TMBU REQUIRED. BFS TMBU TAG-UP --------------- 16-0283 NTD *FLT JSC/DPS PERFORM BFS UPLINK TAG-UP 232 OTC WITH KSC/VFS ON OIS CH 152. OTC CVFS 212 NOT PERFORMED ______ 742 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRSS FLIGHT CODE INSERTION -------------------------- NOTE SFOC AND NASA QC NEEDED AT C AND T LAB FOR CODE LOAD. DO NOT PERFORM NEXT STEP PRIOR TO ER OPEN LOOP CHECKS. 16-0284 NTD TBC LOAD SRSS FLIGHT CODE IN OPF SU72708 232 GROUND STATION PER OMI S5018. TBC CBRS 136 RCRE JIMSPHERE RELEASE ----------------- NOTE ANY PROBLEMS OCCURING WITH 4 HR 15 MIN JIMSPHERE, THE 2 HR JIMSPHERE, OR THE 70 MIN JIMSPHERE, WILL IMMEDIATELY BE REPORTED TO THE NTD BY THE SRO. ALL NOMINAL BALLOON RELEASES AND DATA TRANSFERS TO JSC WILL BE COORDINATED BETWEEN HOUSTON WINDS AND CAPE WINDS. 743 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FLIGHT CREW WEATHER BRIEFING ---------------------------- 16-0285 -03H00M *FLT NTD IMPLEMENT TELEVISED WEATHER COMM (HOLDING) 232 BRIEFING AND DISPLAY TO SU72737 NTD STM FOLLOWING LOCATIONS. WEATHER SU72738 STM GYCC BRIEFING AUDIO TO BE ON OIS CH 231. 111 138 JYVO 1. FLIGHT CREW QUARTERS, O&C GYCC GYVW ROOM 3267, MONITORS 2033 AND PTP GYVO 2034. (CIRCUIT NO.'S 6TVM2080 AND 6TVM2087) 2. ER/ROCC FORECAST FACILITY, ROOM 146. (CIRCUIT NO.'S EITHER 1TVC2079 OR 1TVC2083) 3. LCC 1/3 OSR. (SW 1 INPUT 187 TO OUTPUT 383) 16-0286 STM JYVO VERIFY JSC WX BRIEFING FEED ON COMM 138 OTV SWITCHER SOURCE 187. 16-0287 GYVO GYCC VIDEO FOR WX BRIEFING IN CREW COMM GYVW QUARTERS AND TO ER READY. PTP 16-0288 JYVO GYCC VIDEO FOR WEATHER BRIEFING TO COMM PTP LCC 1/3 OSR READY. 16-0289 GYCC STM VIDEO SYSTEM READY FOR FLIGHT COMM 111 CREW WX BRIEFING ON OIS CH 231. STM NTD 232 NTD *FLT LD 16-0290 *FLT NTD WEATHER BRIEFING COMPLETE. COMM 232 SUPPORT RELEASED. SU72737 NTD STM STM JYVO 138 111 GYCC GYCC GYVW PTP GYVO 744 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0291 *WEA LRD FORECAST FOR TIME OF LAUNCH AT SRB 231 RETRIVAL AREA: LRD NTD 232 PREDICTED WINDS:______ KNOTS NTD LD GUSTING TO:______ KNOTS DIRECTION:______ DEG OMRSD S00L00.085 LIOH CANNISTER INSTL -------------------- 16-0292 -03H00M OVCC OTC READY TO INSTALL LIOH CANNISTERS SU72741 (HOLDING) 212 OR LIOH CANNISTER AND CHARCOAL OTC CECL ODOR FILTER (FOR EDO MISSIONS). NOTE PERFORM NEXT STEP IF VAG60 ACTIVE. 16-0293 OTC CECL CRT (VAG60) CTPE TERMINATE PROGRAM NOT PERFORMED ______ CAUTION DURING LIOH CANNISTER INSTALLATION, CABIN FAN MUST NOT BE SHUTDOWN FOR MORE THAN FIVE MINUTES. (REF OMRS V61AL0.010) 16-0294 OTC ASP PANEL L1 212 CABIN FAN A SW - OFF OTC RECORD TIME: ___________ ASP PANEL F2 RESET MASTER ALARM 745 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE WHEN ONE LIOH CANISTER AND ONE CHARCOAL ODOR FILTER IS MANIFESTED, PLACE LIOH CAN IN SLOT A AND ODOR FILTER IN SLOT B (FOR EDO MISSIONS). 16-0295 OTC OVCC INSTALL TWO LIOH CANISTERS OR LIOH ASP CANISTER AND CHARCOAL ODOR FILTER. VERIFY PANEL DOOR SECURELY LOCKED. REPORT WHEN COMPLETE. 16-0296 OVCC OTC LIOH CANISTERS INSTALLED, 212 READY TO ACTIVATE CABIN FAN A. OTC CECL 16-0297 OTC ASP PANEL L1 212 CABIN FAN A SW - ON OTC RECORD TIME: __________ 16-0298 CECL USING PCGOAL, VERIFY CABIN FAN DELTA PRESS INCREASED (FROM PREVIOUS FAN ON BASELINE) AFTER LIOH CANISTER INSTALLATION. AIR SAMPLE - CREW MODULE ------------------------ 16-0299 ASP PERFORM CLOSEOUT AIR SAMPLE OF CREW MODULE. OMRSD S00FB0.011 746 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRE-INGRESS SWITCH RECONFIG --------------------------- 16-0300 -03H00M ASP OTC READY TO PROCEED WITH PRE- SU72742 (HOLDING) 212 INGRESS SWITCH RECONFIG. 16-0301 OTC CISL PCMMU SWITCH WILL BE CHANGED TO 1. 212 PCMMU BITE BITS 5, 12, 13 AND POSSIBLY 8 AND 11 MAY SHOW FAILED DUE TO BFS AUTO LOAD OF TFL 102 TO 64KB FORMATTER. 16-0302 OTC ASP PANEL C3 212 OI PCMMU PWR SW-1 16-0303 OTC ASP PANEL F6 INSTRUMENT POWER SW - FLT/MPS 16-0304 OTC ASP PANEL F8 INSTRUMENT POWER SW - ON 747 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PCM GSE CONTROL REMOVAL ----------------------- 16-0305 OTC CISL REMOVE GSE CONTROL FROM PCM. 212 16-0306 CISL CRT (SAQ04/VWQ11) VERIFY PCMMU SW SCAN 1 CURSOR CNTL (SAQ04/VWQ11) PCM CONTROL COMMAND - OFF XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT (SAQ04/VWQ11) VERIFY PCMMU COMMAND OFF BITE 1 POWER GOOD 2 MTU GOOD OI DATA VALID OMRSD V75AP0.040-1R 16-0307 CISL OTC PCM GSE CONTROL REMOVAL COMPLETE. 212 748 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0308 -03H00M OTC ASP PANEL R1 (HOLDING) 212 POWER DISTRIBUTION ESS BUS SOURCE FC 1 SW - ON FC 2 SW - ON FC 3 SW - ON AC BUS SNSR (THREE) - OFF, 1 SEC THEN AUTO TRIP VERIFY FC TB'S FUEL CELL READY FOR LOAD 1 TB GRAY R1A02DS011 2 TB GRAY R1A02DS012 3 TB GRAY R1A02DS013 FUEL CELL COOLANT PUMP DELTA P 1 TB GRAY R1A02DS014 2 TB GRAY R1A02DS015 3 TB GRAY R1A02DS016 16-0309 OTC CEPD CRT (SWC02/VWC17) 212 ESS 1BC SRC 1 GREEN 2CA SRC 2 GREEN 3AB SRC 3 GREEN CRT (VWC16) AC BUS SENSOR AC 1 AUTO AC 2 AUTO AC 3 AUTO 16-0310 OTC ASP PANEL R2 212 APU FU TK VLV ENA 1A CB - CLOSED 1B CB - CLOSED 2A CB - CLOSED 2B CB - CLOSED 3A CB - CLOSED 3B CB - CLOSED 749 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CAUTION AFTER COMPLETION OF NEXT STEP, DO NOT LEAVE SELECT SW IN FUEL CELL 1, 2 OR 3 POSITION. NOTE IN NEXT STEP PANEL F9 METER INDICATIONS WILL BE BETWEEN LIMITS CALCULATED FROM CRT READINGS +/- INDICATED TOLERANCE. 16-0311 OTC CEPD CRT (SWCO2/VWC17) 212 READ FC VOLTAGE AND CURRENT. RECORD BELOW. ASP PANEL F9 SELECT, READ AND REPORT FC VOLTAGE AND CURRENT. RECORD BELOW. PNL F9 CRT ------ --- FC 1 V ______ ______ +/- 2.25 VDC A ______ ______ +/- 75 ADC FC 2 V ______ ______ +/- 2.25 VDC A ______ ______ +/- 75 ADC FC 3 V ______ ______ +/- 2.25 VDC A ______ ______ +/- 75 ADC OMRSD S00FA0.365-1R 750 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0312 OTC ASP PANEL R1 212 POWER DISTRIBUTION ESS BUS SOURCE FC 1 SW - OFF FC 2 SW - OFF FC 3 SW - OFF AC BUS SENSOR 1 SW - OFF (1 SEC) THEN MONITOR 2 SW - OFF (1 SEC) THEN MONITOR 3 SW - OFF (1 SEC) THEN MONITOR 16-0313 OTC CEPD CRT (SWC02/VWC17) ESS 1BC SRC 1 RED 2CA SRC 2 RED 3AB SRC 3 RED CRT (VWC16) AC BUS SENSOR AC 1 MON AC 2 MON AC 3 MON 16-0314 OTC ASP PANEL O13 212 ROW A ESS 1BC MN A CONTR CB - CLOSE ROW C ESS 2CA MN B CONTR CB - CLOSE ROW E ESS 3AB MN C CONTR CB - CLOSE 16-0315 OTC ASP PANEL O14 ROW B MN A MN C CONTR CB - CLOSE 16-0316 OTC ASP PANEL O15 ROW B MN B MN A CONTR CB - CLOSE 751 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0317 OTC ASP PANEL O16 212 ROW B MN C MN B CONTR CB - CLOSE ECLSS FCL 1 AND 2 PAYLOAD FLOW ------------------------------ POSITION VERIFICATION --------------------- NOTE PERFORM NEXT STEP FOR SPACEHAB MISSIONS ONLY. 16-0318 OTC CECL RECORD POSITION OF FLOW SU72743 132 PROPORTIONING VALVES: CECL ASP 1. PANEL L1A2 FLOW PROP LOOP 1 - TB-_____ FLOW PROP LOOP 2 - TB-_____ NOTE PERFORM NEXT SUBSTEP FOR LOOP WITH TALKBACK ON PL. 2. PANEL L1A2 FLOW PROP VLV LOOP-SW-INTCHGR UNTIL (15 SEC MAX) FLOW PROP LOOP ___ TB-ICH RECORD GMT__________ VERIFY LESS THAN L-6HRS. (SPACEHAB) VERIFY LESS THAN L-3HRS. (NEUROLAB) NOT PERFORMED ______ SS2 OMRSD P095PR.893 NOT PERFORMED ______ 752 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DURING FOLLOWING VERIFICATION, MASTER ALARMS WILL OCCUR. ASP WILL RESET AS REQUIRED. 16-0319 CECL ASP PANEL L1A2 FLOW PROP VLV LOOP 1 SW - PAYLOAD HX UNTIL (15 SEC MAX) FLOW PROP LOOP 1 TB PL 16-0320 CECL CRT (VAG34 PG-B) VERIFY FC LOOP 1 VALVE POSN PAYLD FCL1 FLOWRATE MEET LCC REQUIREMENTS. 16-0321 CECL ASP PANEL L1A2 FLOW PROP VLV LOOP 1 SW - INTCHGR UNTIL (15 SEC MAX) FLOW PROP LOOP 1 TB ICH 16-0322 CECL CRT (VAG34 PG-B) VERIFY FC LOOP 1 VALVE POSN INTCH FCL1 FLOWRATE MEET LCC REQUIREMENTS. 753 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0323 CECL ASP PANEL L1A2 FLOW PROP VLV LOOP 2 SW - PAYLOAD HX UNTIL (15 SEC MAX) FLOW PROP LOOP 2 TB PL 16-0324 CECL CRT (VAG34 PG-B) VERIFY FC LOOP 2 VALVE POSN PAYLD FCL1 FLOWRATE MEET LCC REQUIREMENTS. 16-0325 CECL ASP PANEL L1A2 FLOW PROP VLV LOOP 2 SW - INTCHGR UNTIL (15 SEC MAX) FLOW PROP LOOP 2 TB ICH 16-0326 CECL CRT (VAG34 PG-B) SU72743 VERIFY FC LOOP 2 VALVE POSN INTCH FCL1 FLOWRATE MEET LCC REQUIREMENTS. 16-0327 OTC CECL VERIFY ECLSS CONFIGURED FOR H2O LOOP 132 1A/2 CB OPENING. 16-0328 OTC ASP PANEL L4 132 ROW F AC1 H2O LOOP PUMP 1A/2 PH A CB - OPEN PH B CB - OPEN PH C CB - OPEN SRSS FLIGHT CODE LOAD INSERTION ------------------------------- COMPLETE -------- 16-0329 CBRS TBC SRSS FLIGHT CODE LOAD INSERTION SU72708 136 COMPLETE PER S5018. 754 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0330 SRO NTD FCA VAN READY TO SUPPORT SRBTS 232 CHECKOUT. SRBTS POWER ON -------------- NOTE PERFORM NEXT STEP 30 MINUTES PRIOR TO END OF HOLD. 16-0331 NTD TBC POWER UP SRB TRACKING SYSTEM. SU72711 232 TBC CBRS 136 16-0332 CBRS CURSOR CNTL (SWRB2) LH BEACON INH ON - ON RH BEACON INH ON - ON LH DFI POWER ON - ON RH DFI POWER ON - ON 16-0333 CBRS CRT (SWRB2) LH AND RH TRACKING BEACON VOLT 26 TO 32 V LH AND RH TRACKING BEACON CURR LESS THAN 0.5 AMP LH AND RH TRACKING BEACON TEMP 34.6 TO 103.4 DEG F 16-0334 CBRS CRT (SWRB2) RECORD LH TRACKING BEACON CURR ____ AMPS RH TRACKING BEACON CURR ____ AMPS 16-0335 CBRS CURSOR CNTL (SWRB2) LH AND RH BEACON INH OFF - OFF 755 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0336 CBRS CRT (SWRB2) LH AND RH TRACKING BEACON VOLT 26 TO 32 LH AND RH TRACKING BEACON TEMP 34.6 TO 103.4 DEG F LH AND RH TRACKING BEACON CURR HAS INCREASED 0.48 +/- 0.20 AMPS FROM PREPOWER ON VALUE. RECORD LH CURR _____ AMPS RH CURR _____ AMPS 16-0337 CBRS ALLOW 3 MINUTE WARM UP PRIOR TO RANGE INTERROGATION. 16-0338 CBRS TBC SRBTS POWER UP COMPLETE. READY 136 FOR ER FCA VAN CHECKOUT OF TBC NTD SRBTS. CBRS REQUEST SRO SUPPORT 232 ON OIS CH 175. NTD SRO 16-0339 SRO CBRS LH SRBTS INTERROGATION HAS STARTED 175 AND VEHICLE RESPONDING. 16-0340 CBRS CRT (SWRB2) VERIFY LH TRACKING SYSTEM CURR LESS THAN 1.2 AMP 16-0341 SRO CBRS LH SRBTS TESTING COMPLETE. RH SRBTS INTERROGATION HAS STARTED AND VEHICLE RESPONDING. 16-0342 CBRS CRT (SWRB2) VERIFY RH TRACKING SYSTEM CURR LESS THAN 1.2 AMP 16-0343 SRO CBRS RH SRBTS TESTING COMPLETE. FAXING DATA TO FIRING ROOM 1/3 AT 861-0471/ 861-0472. 756 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0344 CBRS RECORD BEACON DATA LH DATA RH DATA VAN/RADAR USED _______ _______ VAN LOCATION _______ _______ POWER OUTPUT (XX) _______ _______ SENSITIVITY (XX) _______ _______ ANT POL _______ _______ PULSE UPPER (X) _______ _______ LOWER (X) _______ _______ PULSE CODE (XX) _______ _______ DELAY (XX) _______ _______ JITTER _______ _______ RECOVERY TIME (XX) _______ _______ PULSE WIDTH (XX) _______ _______ HIGH 1000 PRF INTERR FREQ (X) _______ _______ HIGH 1000 PRF TRANS FREQ (X) _______ _______ LOW 160 PRF INTERR FREQ (X) _______ _______ LOW 160 PRF TRANS FREQ (X) _______ _______ TIME _______ _______ COMPATIBILITY _______ _______ 16-0345 CBRS SRO C-BAND BEACON TEST DATA SATISFACTORY, 175 FCA VAN SUPPORT CAN BE RELEASED. ER NOW HAS CONTROL OF SRB TRACKING BEACONS THRU LAUNCH. 757 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0346 SRO CBRS SRBTS FCA CHECKS COMPLETE. 175 CBRS TBC 136 TBC NTD 232 OMRSD S00FE0.240-1 16-0347 SRO NTD IF PAD A LAUNCH, FCA VAN READY SEC 232 TO EXIT UCS15. HAVE SECURITY NTD *SEC ALLOW ACCESS THROUGH ROADBLOCK A/B-13 NOT PERFORMED ______ 16-0348 SRO NTD IF PAD B LAUNCH, FCA VAN READY SEC 232 TO EXIT UCS 4. HAVE SECURITY NTD *SEC ALLOW ACCESS THROUGH GATES 6 AND 6T. NOT PERFORMED ______ 758 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SLF NAVAIDS ACTIVATION ---------------------- NOTE SWITCHING OF THE TACAN GROUND STATION TRANSPONDER WILL RESULT IN MOMENTARY SIGNAL DROPOUT. THE TACAN GROUND STATION OPERATOR IS TO NOTIFY CNSE ON OIS CH 173 IF SWITCHING OCCURS OR BECOMES NECESSARY. REDUNDANT TACAN TRANSPONDER CAPABILITY IS MANDATORY FOR ENTRY. THIS REQUIREMENT CAN BE SATISFIED BY ONE GROUND STATION WITH DUAL STRING (DS) TRANSPONDERS OR BY TWO GROUND STATIONS WITH SINGLE STRING (SS) TRANSPONDER CAPABILITY. 16-0349 NTD STM VERIFY TACAN STATUS AT KSC. COMM 232 SU72745 STM GYCC SU72757 111 GYCC FTAC 117 16-0350 -03H00M FTAC GYCC PERFORM FOLLOWING: (HOLDING) 117 GYCC STM 1. TACAN STATION AT KSC _____ COMM 111 (IS/IS NOT) SUPPORTING. STM NTD 232 2. TRANSPONDER STATUS: NTD OTC OTC CNSE __________(DS/SS/NONE) 212 16-0351 LRD *DCD VERIFY TACAN AT PAFB SUPPORTING. 135 759 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0352 *DCD LRD TACAN STATION AT PAFB__________ 135 (IS/IS NOT) SUPPORTING. TRANSPONDER LRD NTD STATUS IS SINGLE STRING. 232 NTD OTC OTC CNSE 212 WARNING NEXT STEP IS HAZARDOUS DUE TO RF RADIATION. 16-0353 -03H00M NTD OTC REQUIRED TACAN STATIONS READY TO (HOLDING) 232 SUPPORT NAVAIDS ACTIVATION. OTC CNSE PERFORM NAVAIDS ACTIVATION ON 212 CH 212. 16-0354 CNSE HOME CMD KEY - PRESS CONSOLE KYBD VAA40 PERF PGM KEY - PRESS SELECT APPL PG-B VAA40 PFPK VAA40 - PRESS SELECT WARM START SELECT VWN42 760 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0355 CNSE ASP PANEL O7 TACAN 1 MODE SW - GPC CHANNEL TW - 059Y ANT SEL SW - AUTO TACAN 2 MODE SW - GPC CHANNEL TW - 059Y ANT SEL SW - AUTO TACAN 3 MODE SW - GPC CHANNEL TW - 059Y ANT SEL SW - AUTO GMT__________ 761 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0356 CNSE CURSOR CNTL (VWN42) 1. TACAN 1 CONTROL WORD ISSUE XMIT CURSOR KEY - PRESS FOLLOW SOFTWARE DIRECTIONS TO SELECT Y MODE, TR AND CHANNEL 59, SELF TEST OFF EXEC CMD KEY - PRESS PFK1 - PRESS ANTENNA CMD - LOWER 2. TACAN 2 CONTROL WORD ISSUE XMIT CURSOR KEY - PRESS FOLLOW SOFTWARE DIRECTIONS TO SELECT Y MODE, TR AND CHANNEL 59, SELF TEST OFF EXEC CMD KEY - PRESS PFK1 - PRESS ANTENNA CMD - LOWER 3. TACAN 3 CONTROL WORD ISSUE XMIT CURSOR KEY - PRESS FOLLOW SOFTWARE DIRECTIONS TO SELECT Y MODE, TR AND CHANNEL 59, SELF TEST OFF EXEC CMD KEY - PRESS PFK1 - PRESS ANTENNA CMD - LOWER 762 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0357 CNSE CRT (VWN42) TACAN 1 SW STAT ON TACAN 2 SW STAT ON TACAN 3 SW STAT ON TACAN 1 POWER STAT ON TACAN 2 POWER STAT ON TACAN 3 POWER STAT ON 16-0358 CNSE ASP PANEL 08 MLS CHANNEL 1 TW - 6 2 TW - 6 3 TW - 6 16-0359 CNSE ASP PANEL 08 RADAR ALTIMETER 1 SW - ON 2 SW - ON GMT__________ 16-0360 CNSE CRT (VWN42) RA 1 RALT SW STATUS - ON RA 2 RALT SW STATUS - ON RA 1 RALT READY - ON RA 2 RALT READY - ON RECORD RALT 1 ALT __________ BD RALT 2 ALT __________ BD 763 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0361 CNSE ASP PANEL 07 NOTE IF TACAN 1, 2 OR 3 WILL NOT LOCK TO GROUND STATION, PERFORM APPROPRIATE SUBSTEP. 1. TACAN 1 MODE SW - OFF MODE SW - T/R MODE SW - GPC NOT PERFORMED ______ SS1 2. TACAN 2 MODE SW - OFF MODE SW - T/R MODE SW - GPC NOT PERFORMED ______ SS2 3. TACAN 3 MODE SW - OFF MODE SW - T/R MODE SW - GPC NOT PERFORMED ______ SS3 ENTIRE STEP NOT PERFORMED ______ 764 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0362 CNSE CURSOR CNTL (VWN42) NOTE PERFORM APPROPRIATE SUBSTEP IF TACAN 1, 2 OR 3 MODE SW WAS CYCLED. 1. TACAN 1 CONTROL WORD ISSUE XMIT CURSOR KEY - PRESS FOLLOW SOFTWARE DIRECTIONS TO SELECT Y MODE, TR AND CHANNEL 59, SELF TEST OFF EXEC CMD KEY - PRESS PFK1 - PRESS ANTENNA CMD - LOWER NOT PERFORMED ______ SS1 2. TACAN 2 CONTROL WORD ISSUE XMIT CURSOR KEY - PRESS FOLLOW SOFTWARE DIRECTIONS TO SELECT Y MODE, TR AND CHANNEL 59, SELF TEST OFF EXEC CMD KEY - PRESS PFK1 - PRESS ANTENNA CMD - LOWER NOT PERFORMED ______ SS2 3. TACAN 3 CONTROL WORD ISSUE SMIT CURSOR KEY - PRESS FOLLOW SOFTWARE DIRECTIONS TO SELECT Y MODE, TR AND CHANNEL 59, SELF TEST OFF EXEC CMD KEY - PRESS PFK1 - PRESS ANTENNA CMD - LOWER NOT PERFORMED ______ SS3 ENTIRE STEP NOT PERFORMED ______ 765 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0363 CNSE CRT (VWN42) VERIFY TACAN 1 RNG VALID GO TACAN 2 RNG VALID GO TACAN 3 RNG VALID GO TACAN 1 BRNG VALID GO TACAN 2 BRNG VALID GO TACAN 3 BRNG VALID GO NOTE PERFORM NEXT STEP ONLY IF TACAN THUMBWHEELS TO BE SET TO CHANNEL OTHER THAN 059Y. 16-0364 CNSE ASP PANEL 07 TACAN 1 CHANNEL TW - __________ TACAN 2 CHANNEL TW - __________ TACAN 3 CHANNEL TW - __________ NOT PERFORMED ______ NOTE PERFORM GPS ACTIVATION FOR FLIGHT ONLY FOR VEHICLES OV103, OV104, AND OV105. GPS ACTIVATION FOR FLIGHT ------------------------- NOT PERFORMED ______ 766 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0365 CNSE CONSOLE KYBD (VSN59 PAGE-B) VSN59 PERF PROGRAM KEY - PRESS SELECT PAGE B NOTE DEU IS REQUIRED FOR THE GPS ACTIVATION. 16-0366 CNSE OTC CHANGE RESPONSIBLE CONSOLE FOR 132 A CRT TO CONSOLE C2. DPS CAN OTC CDPS ALSO EXPECT IO ERRORS DURING GPS POWER UP. 16-0367 CDPS CONSOLE KYBD HOME CMD KEY - PRESS ISSU N72IV10YD #B002 (WHERE Y = DEU - 1) XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS HOME CMD KEY - PRESS C CO _DEUXG LDBA C2 XMIT CMD KEY - PRESS 16-0368 CDPS OTC RESPONSIBLE CONSOLE FOR DEU 132 NO.___ NOW ASSIGNED TO C2. OTC CNSE NOTE DO NOT PERFORM NEXT STEP IF GPS PREAMPS ARE ALREADY POWERED ON. 16-0369 CNSE ASP PANEL A13 GPS PRE-AMP UC SW - MN C LC SW - MN A NOT PERFORMED ______ 16-0370 CNSE ASP PANEL A13 VERIFY GPS ENCRYPT SW NORMAL 767 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0371 CNSE CURSOR CNTL (VSN59) GPS POWER UP - 2 XMIT CURSOR KEY - PRESS START TEST XMIT CURSOR KEY - PRESS 16-0372 CNSE CRT (VSN59) FOLLOW PROGRAM PROMPTS: 1. BYPASS SITE SELECT. SELECT PFK 2 2. BYPASS PREAMP POWER UP. SELECT PFK 4 3. PERFORM I/O START. SELECT PFK 1. 4. SELECT CRT FOR SPEC 55. 5. GPS POWER UP NOTE PROGRAM WILL MONITOR FOR RECEIVER TO POWER UP AND THEN MODE FROM SELF TEST TO NAV. MODING WILL TAKE APPROXIMATELY 30 SECONDS TO COMPLETE. 16-0373 CNSE ASP PANEL A13 GPS POWER SW - ON 16-0374 CNSE CRT (VSN59 PAGE B) VERIFY NO MESSAGES FOR RPU FAIL OR BAT LOW AND GPS IS IN NAV MODE. (HDR WD = XFFFF) 16-0375 CNSE CONSOLE KYBD (VSN59 PAGE B) PFK 7 - PRESS (TERMINATE) NOTE GPS WILL AUTOMATICALLY MODE TO INIT WHEN THE ITEM 10 IS EXECUTED. 16-0376 CNSE CURSOR CNTL (VSN59) ITEM 10 I/O XMIT CURSOR KEY - PRESS START TEST XMIT CURSOR KEY - PRESS 768 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0377 CNSE CRT (VSN59 PAGE B) VERIFY GPS IN INIT MODE. (HDR WD = XEEEE) 16-0378 CNSE CURSOR CNTL (VSN59) NAV GPS 2 - ITEM 18 XMIT CURSOR KEY - PRESS START TEST XMIT CURSOR KEY - PRESS 16-0379 CNSE CRT (VSN59 PAGE B) VERIFY GPS IN NAV MODE (HDR WD = XFFFF) 16-0380 CNSE CURSOR CNTL (VSN59) PFK 7 - PRESS (TERMINATE) 16-0381 CNSE CURSOR CNTL (VSN59 PAGE B) SPEC RESUME XMIT CURSOR KEY - PRESS START TEST XMIT CURSOR KEY - PRESS 16-0382 CNSE CRT (VSN59 PAGE B) RESUME VERIFIED CRT RETURN TO C12 ----------------- 16-0383 CNSE CURSOR CNTL (VSN59 PAGE B) CRT RETURN ..... XMIT CURSOR KEY - PRESS C CO _DEUXG LDBA C12 XMIT CMD KEY - PRESS 16-0384 CNSE CURSOR CNTL (VSN59 PAGE B) NAV MONITOR XMIT CURSOR KEY - PRESS START TEST XMIT CURSOR KEY - PRESS 16-0385 CNSE CRT (VSN59 PAGE B) VERIFY NAVIGATION MONITOR ACTIVE 769 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0386 CNSE OTC CRT HAS BEEN RETURNED TO C12. 132 OTC CDPS NOTE DO NOT PERFORM NEXT STEP IF GPS/INS ALREADY POWERED. 16-0387 CNSE ASP PANEL A13 GPS GPS/SIGI POWER SW - ON GPS/SIGI ENCRYPT - NORMAL GMT______ NOT PERFORMED ______ GPS ACTIVATION FOR FLIGHT COMPLETE ---------------------------------- 16-0388 CNSE OTC NAVAIDS ACTIVATION COMPLETE. SU72745 212 OTC NTD 232 770 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT FIVE STEPS IF PRLA PAYLOAD SELECT SWITCH IS TO BE REPOSITIONED FOR FLIGHT. | DO NOT PERFORM NEXT FIVE | STEPS FOR STS-93. | 16-0389 OTC CPLE PERFORM PRLA STATUS VERIFICATION 212 ASP AND CONFIGURE PRLA PAYLOAD SELECT SWITCH FOR FLIGHT. NOT PERFORMED ______ 16-0390 CPLE CRT (SAT01/VWT33) VERIFY PRLA SYSTEM MEETS LCC REQUIREMENTS. PNL A6U PAYLOAD SELECT SW POS - MON LATCH/RELEASE SWITCH 1 - OFF SWITCH 2 - OFF SWITCH 3 - OFF SWITCH 4 - OFF SWITCH 5 - OFF LOGIC POWER SYS 1 SW - OFF SYS 2 SW - OFF LATCH STATUS SEL 2 LATCH 3 SYS 1 - LAT (INVERT) SYS 2 - LAT (INVERT) LATCH 4 SYS 1 - LAT (INVERT) SYS 2 - LAT (INVERT) LATCH 5 SYS 1 - LAT (INVERT) SYS 2 - LAT (INVERT) NOT PERFORMED ______ 771 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0391 CPLE ASP PANEL A6U PAYLOAD RETENTION PAYLOAD SELECT SW - 1 PAYLOAD RETENTION LATCHES 1 TB BP 2 TB BP 3 TB BP 4 TB BP 5 TB BP READY TO LATCH 1 TB BP 2 TB BP 3 TB BP 4 TB BP 5 TB BP NOT PERFORMED ______ 16-0392 CPLE CRT (VAA40) VERIFY RETENTION LATCH STATUS PAYLOAD SEL SW POS 1 SEL 1 LATCH 1 SYS 1 - (BLANK) SYS 2 - (BLANK) LATCH 2 SYS 1 - (BLANK) SYS 2 - (BLANK) NOT PERFORMED ______ 16-0393 CPLE OTC PRLA SYSTEM STATUS VERIFICATION AND ASP SWITCH CONFIGURATION FOR FLIGHT COMPLETE. NOT PERFORMED ______ 772 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLEAR C/W MEMORY ---------------- 16-0394 OTC ASP PANEL R13U SU72746 212 CISL C/W PARAMETER STATUS SW - INHIBITED, HOLD. RECORD MATRIX LIGHTS ON. RECORD IN APPENDIX P-3 VOL 4. 16-0395 OTC ASP PARAMETER STATUS SW - RELEASE 16-0396 OTC ASP MEMORY SW - READ, HOLD RECORD MATRIX LIGHTS ON. RECORD IN APPENDIX P-5 VOL 4. 16-0397 OTC ASP MEMORY SW - RELEASE 16-0398 OTC ASP MEMORY SW - CLEAR, RELEASE MEMORY SW - READ, HOLD RECORD MATRIX LIGHTS ON. RECORD IN APPENDIX P-4 VOL 4. 16-0399 OTC CMQC ABSENCE OF PARAMETERS 062, 072, 212 082, 092, 102, 112 IN PRECEDING STEP SATSIFIES NOTED OMRS REQUIREMENTS. OMRSD V45CG0.040-A OMRSD V45CG0.040-B OMRSD V45CG0.040-C 16-0400 OTC ASP MEMORY SW - RELEASE 16-0401 OTC ASP PANEL F7 SU72746 212 REPORT ANNUNCIATOR ON LITES. RECORD IN APPENDIX P-1 VOL 4. NOTE PERFORM NEXT TWO STEPS IF PPOV OR MINI CAMERA INSTALLED. 16-0402 OTC ASP PANEL R14 212 ROW D MNC TV CABIN CB - CLOSE NOT PERFORMED ______ 773 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0403 OTC ASP PANEL R12A2 STORAGE CONTAINER 212 VERIFY TEAC RECORDER PWR ON MODE REC NOT PERFORMED ______ 16-0404 OTC CGSS START ONE HCU PUMP PER SU72719 OMI V2160. LRD COMM CHECKS --------------- NOTE PERFORM COMM CHECKS IMMEDIATELY FOLLOWING LAUNCH DIRECTOR WX BRIEFING. 16-0405 -03H00M LRD LSO KSC READY TO CONFIGURE FOR CONVOY (HOLDING) LF1 COMM CHECKS. 16-0406 LRD STM VERIFY READY FOR CONVOY COMM COMM 135 CHECKS ON UHF 259.7 MHZ, STM GYCC CONVOY COMMANDER AND COOLING 111 NETS. 16-0407 GYCC GYRM VERIFY TECHNICIAN ON STANDBY COMM NET AT CONVOY COMMANDER VEHICLE 107 TO SUPPORT COMM CHECKS. 16-0408 GYCC *VCE CONFIGURE UHF, CONVOY COMMANDER COMM COMM *VCT AND COOLING NETS FOR CONVOY COORD COMM CHECKS. NET 16-0409 GYCC *VCE REQUEST MILA CONFIGURE UHF 259.7 COMM COMM MHZ ANTENNA TO SUPPORT KSC CONVOY COORD COMM CHECKS. VERIFY COMPLETION. NET *VCE *GC *GC *MIL 16-0410 GYCC STM READY TO SUPPORT LRD COMM COMM 111 CHECKS. STM LRD 135 774 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0411 LRD NTD READY FOR CONVOY COMM CHECKS. 232 REQUEST CONCURRENCE FOR NIB NTD OTC COMM CHECKS ON ORBITER UHF 259.7 MHZ. 16-0412 LRD LSO READY TO PERFORM CONVOY COMM LF1 CHECKS ON UHF WITH HOUSTON COMM TECH (*VCT) AND ON CONVOY COMMANDER AND COOLING NETS WITH HOUSTON VOICE (*VCE). 16-0413 LRD *VCT PERFORM UHF/OMNI VOICE CHECKS UHF NCC ON 259.7 MHZ. 16-0414 LRD *VCE PERFORM KSC CONVOY COMMANDER AND CCN NCC AND COOLING NET COMM CHECKS. 16-0415 LRD LSO CONVOY RADIO CHECKS ON UHF, COMM LF1 CONVOY COMMANDER AND COOLING LRD STM NETS WITH JSC ARE COMPLETE. 135 STM GYCC 111 16-0416 GYCC *VCE KSC CONVOY COMM CHECKS COMPLETE. COMM COMM MILA UHF 259.7 MHZ ANTENNA MAY COORD BE RECONFIGURED TO LAUNCH SUPPORT. NET REPORT COMPLETION. *VCE *GC 16-0417 GYCC STM MILA UHF 259.7 MHZ ANTENNA HAS COMM 111 BEEN RECONFIGURED TO LAUNCH STM LRD SUPPORT. 135 NOTE PERFORM NEXT STEP IF ALTERNATE LANDING SITE CONVOY COMMANDER NET ACTIVATED TO ______ (DFRF OR WSSH). 16-0418 LRD NCC COMM CHECK ON ALTERNATE LANDING (ALS SITE CONVOY COMMANDER NET. CCN) NOT PERFORMED ______ 775 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- READY TO RESUME COUNT --------------------- 16-0419 NTD ATTENTION ALL PERSONNEL, THE CDC 232 WILL RESUME COUNTING AT T-03 HRS IN 5 MINUTES. RESUME COUNT ------------ 16-0420 -03H00M CGLS NTD HOLD WILL TERMINATE AND CDC WILL (HOLDING) 232 START COUNTING AT __/__/__ GMT HH MM SS 16-0421 -03H00M NTD T-03H00M AND COUNTING. COUNTING PA 232 ER OPEN LOOP CMD TEST --------------------- 16-0422 SRO NTD REQUEST SRO CLEARANCE (416.5 MHZ SU72797 232 OPEN LOOP) FOR CMD AUTO CARRIER SYSTEM CHECKS (30 MINUTE DURATION). 776 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TIMER CONFIGURATION | ------------------- | | TIMER NO. 1 WINDOW REMAINING | ---------------------------- | | 16-0423 CGLS JTCR SETUP WINDOW REMAINING TIMER | 178 NO. 1 TO FOLLOWING TIME: | (PHONE 1-2290) | | H M S | - - - | | NOTE | | TIMER NO. 1 IS SET TO THE | VALUE OF THE WINDOW. | | TIMER NO. 1 _:__:__ (WINDOW REMAINING) | | 16-0424 JTCR FOR TIMER NO. 1, AT THE T-9 MIN. | HOLDING POINT: | | ACTIVE OVRD SWITCH - ON | COUNTHOLD SWITCH - OFF | | WHEN TIMER NO. 5 DECREMENTS TO ZERO: | | ACTIVATE COUNTHOLD SWITCH - AUTO | | NOTE | | TIMER NO. 1 SHOULD DECREMENT | WHEN HOLDS OCCUR FROM THIS | POINT TO COMPLETION OF WINDOW. | | TIMER NO. 2 LOX DRAIN BACK ELAPSED | ---------------------------------- | HOLD TIME | --------- | | 16-0425 CGLS JTCR SET LOX DRAIN BACK HOLD TIMER | 178 NO. 2 TO +0:00. | 777 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE | | TIMER NO. 2 COUNTS AT ANY | HOLD AFTER T-5 MINS. AND | COUNTING. | | 16-0426 CGLS JTCR VERIFY TIMER NO. 2 IN REMOTE AND | 178 IN COUNTING UP MODE. | | TIMER NO. 5 HOLD TIME REMAINING | ------------------------------- | | 16-0427 CGLS JTCR VERIFY HOLD TIME REMAINING | (TIMER NO. 5) | SET TO FOLLOWING TIMES: | | NOTE | | THE TIMES ARE TO REFLECT | THE PLANNED HOLD DURATION. | AFTER T-9 MIN PLANNED HOLD | EXPIRES, TIMER NO. 5 WILL | ACCUMULATE TIME AT ANY | ADDITIONAL HOLD. | | T-20 MIN. HOLD ___:___:___ (HOLD TIME | REMAINING) | | T-9 MIN. HOLD ___:___:___ (HOLD TIME | REMAINING) | | 16-0428 CGLS HOME CMD KEY - PRESS | CONSOLE KYBD | A CM TMDS | XMIT CMD KEY - PRESS | EXEC CMD KEY - PRESS | | 16-0429 CGLS HOME CMD KEY - PRESS | CONSOLE KYBD | A CM GCDKTIM2E | XMIT CMD KEY - PRESS | EXEC CMD KEY - PRESS | | 778 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FINAL INSPECTION - COMPLETE --------------------------- 16-0430 *FIT NTD FINAL INSPECTION COMPLETE. SU72748 232 TEAM LEAVING PAD (SEQ 57 S0007VL4 NTD OTC AND S6444). OTC OVCC 212 NTD *PRL NET 105 OMRSD S00U00.020-A-1 OMRSD S00U00.020-C-1 OMRSD S00U00.020-D-1 16-0431 -03H00M NTD STM PROVIDE VIDEO TRACKING AND COMM 232 RECORDING OF FINAL INSPECTION STM JYVO TEAM FROM PAD TO ROADBLOCK 138 JYVR A/B-11 (SEE JYVO FIG 4). 16-0432 NTD *SCC VERIFY FINAL INSPECTION TEAM 232 BACK TO ROADBLOCK A/B-11. *SCC *PSE NET 105 16-0433 *PSE *SCC FINAL INSPECTION TEAM AT ROADBLOCK NET A/B-11. 105 *SCC NTD 232 *PAC 16-0434 NTD STM STOP VIDEO TRACK AND RECORDING COMM 232 OF FINAL INSPECTION TEAM. STM JYVO 138 JYVR 779 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TOP-OFF SS SYS -------------- NOTE PERFORM NEXT STEP IF SS WATER TANK REQUIRES TOP-OFF. 16-0435 -03H00M STM JBWC TOP OFF ELEVATED SOUND WSSA 111 SUPPRESSION WATER TANK PER OMI M3189.001. NOT PERFORMED ______ 780 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB RGA POWERUP AND TORQUE TEST ------------------------------- 16-0436 -03H00M TBC CAFC PERFORM SRB RGA POWER UP AND SU72802 136 TORQUE TEST. 16-0437 CAFC CURSOR CNTL (SAB19/SWB01) SRB RGA - OPS MAN XMIT CURSOR KEY - PRESS 16-0438 CAFC CURSOR CNTL (BAF05/BWF01) SRGA POWER UP WITH TQ ALL SRGA'S XMIT CURSOR KEY - PRESS 16-0439 CAFC CURSOR CNTL (BAF05/BWF01) START TEST XMIT CURSOR KEY - PRESS NOTE SRGA TORQUE TEST IS DELAYED APPROXIMATELY 5 MIN. FROM TIME LAST SRGA IS TURNED ON. 16-0440 CAFC CRT (BAF05/BWF01) VERIFY ALL SRB RGA'S POWERED UP WITHOUT ERROR. OMRSD S00FF0.215-1R 16-0441 CAFC CRT (BAF05/BWF01) VERIFY SRB RGA TORQUE TEST COMPLETE WITHOUT ERROR. OMRSD S00FF0.230-1R OMRSD S00000.643-1R 16-0442 CAFC APPL PAGE (BAF05/BWF01) PFK 15 KEY - PRESS (TERM BAF05) 781 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE SRB RGA LCC EMON ------------------------- 16-0443 CAFC APPL PAGE A (SAB20/SWB02) PFK-13 KEY - PRESS (ACT EMON SETUP) 16-0444 CAFC CURSOR CNTL (SAB20/SWB02 PAGE A) A - SRB RGA XMIT CURSOR KEY - PRESS 16-0445 CAFC APPL PAGE A (SAB20/SWB02) PFK-13 KEY - PRESS (DEACT EMON SETUP) 16-0446 CAFC TBC SRB RGA POWERUP, TORQUE TEST AND LCC 136 ACTIVATION COMPLETE. CREW INGRESS WEATHER UPDATE --------------------------- 16-0447 -02H55M STM JBDY VERIFY NO ELECTRICAL STORM SU72773 111 WITHIN 5 NM OF LAUNCH PAD. JBDY *WEA 231 16-0448 JBDY STM ELECTRICAL STORM WITHIN 5 NM OF 111 LAUNCH PAD. STM NTD 232 __________(YES/NO) 782 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FLIGHT CREW DEPART O&C BUILDING TO PAD -------------------------------------- 16-0449 -02H55M VIT NTD VERIFY READY FOR FLIGHT CREW TO SU72775 232 DEPART O&C BUILDING TO PAD. (7-3903/3901 RECORDED PHONE) 16-0450 -02H55M *AVN NTD ASTRO VAN DEPARTING O & C WITH SEC NET FLIGHT CREW. SU72777 105 NTD OTC 232 *PAC *SCC OTC OVCC 212 16-0451 -02H55M NTD STM FLT CREW DEPARTING O&C ENROUTE COMM 232 TO LAUNCH PAD, VIDEO TRACK AND STM JYVO RECORD THRU INGRESS (SEE JYVO 138 JYVR FIGURE 4). 16-0452 NTD ALL FLT CREW DEPARTING O&C ENROUTE TO 232 THE LAUNCH PAD, ALL CONSOLE 212 OPERATORS MONITOR YOUR SYSTEM'S 136 PERFORMANCE AND NOTIFY THE NTD IMMEDIATELY OF ANY PROBLEMS AND/OR TRENDS THAT COULD AFFECT FLIGHT CREW OR CLOSEOUT CREW SAFETY. 16-0453 STM JPHO FLIGHT CREW DEPARTING O&C ENROUTE 111 TO PAD. STAND BY TO PHOTOGRAPH FLIGHT CREW UPON ARRIVAL AT WHITE ROOM. 783 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MILA AZMITH/ELEVATION READOUT ----------------------------- 16-0454 -02H55M STM JPHO VERIFY READY TO PROCEED WITH MILA 111 AZMITH/ELEVATION READOUT. 16-0455 -02H55M STM *MIL VERIFY POINTING DATA FOR APPLICABLE 111 PAD BEING TRANSMITTED TO SLF TV TOWERS 1 AND 2 AS SPECIFIED BELOW: PAD TV TOWER AZIMUTH ELEV. --- -------- ------- ------ A 1(SOUTH) 89 DEG. 1 DEG. 2(NORTH) 99 DEG. 1 DEG. B 1(SOUTH) 69.5 DEG. 1 DEG. 2(NORTH) 85.5 DEG. 1 DEG. (ALL READINGS +/- 2 DEG.) 16-0456 STM JPHO SOUTH TWR (TOWER 1) GIVE FOL DATA: 111 READOUT POINTING DATA AZIMUTH _____ DEG ELEVATION _____ DEG 16-0457 STM JPHO NORTH TWR (TOWER 2) GIVE FOL DATA: 111 READOUT POINTING DATA AZIMUTH _____ DEG ELEVATION _____ DEG 16-0458 STM *MIL VERIFY READOUTS. 111 16-0459 STM NTD MILA AZMITH/ELEVATION READOUT 232 COMPLETE. 784 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- COLA IDENTIFICATION ------------------- 16-0460 NTD SRO IDENTIFY ANY COLLISION AVOIDANCE SU72804 232 (COLA'S) TIMES FOR THIS LAUNCH WINDOW OR LAUNCH PERIOD. COLA 1 __________Z TO __________Z COLA 2 __________Z TO __________Z COLA 3 __________Z TO __________Z 16-0461 JSTC WMED MEDICAL PERSONNEL ON SITE AT MED 111 STM MULTI-FUNCTIONAL FACILITY FOR STM NTD FLIGHT CREW/GROUND SUPPORT 232 PERSONNEL MEDICAL CARE. NTD *SCC CLEAR ASTRO VAN THRU ROADBLOCK A/B-11 ------------------------------------- 16-0462 -02H45M NTD *SCC VERIFY NO CONSTRAINTS TO CLEARING 232 ASTROVAN THRU A/B-11 ROADBLOCK TO BASE OF FSS AND SECURITY ESCORT TO PAD MAIN GATE. 785 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0463 -02H45M NTD *SEC CLEAR SECURITY ESCORT WITH SEC 232 ASTROVAN THRU A/B-11 ROADBLOCK TO PAD. ESSENTIAL PERSONNEL IN ASTRO VAN -------------------------------- (XX = AS REQ'D TO SUPPORT MISSION) JSC GSS SEC --- --- --- PRIME XX CREW SUIT TECH 1 DRIVER 1 ESCORT 2 NASA 2 J-BOSC ESSENTIAL PERSONNEL IN SECURITY ------------------------------- ESCORT VEHICLE -------------- J-BOSC ------ DRIVER & ESCORT 2 16-0464 NTD *AVN FLIGHT CREW IS CLEARED THRU SEC NET A/B-11 ROADBLOCK TO BASE OF FSS 105 WITH ESCORT VEHICLE TO GATE. 16-0465 *SEC NTD ASTRO VAN HAS PASSED THRU SEC 232 A/B-11 ROADBLOCK. NTD *SCC OTC *PAC OTC OVCC 212 786 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FINAL INSPECTION REPORT ----------------------- NOTE CICE WILL REPORT ANY OMRS VIOLATIONS, IPR CONDITIONS OR DETRIMENTAL ENVIRONMENTAL CONDITIONS ON CMD CHANNEL. 16-0466 -02H45M CICE NTD NOTIFY LAUNCH DIRECTOR AND LAUNCH 232 MANAGERS THAT FINAL INSPECTION TEAM READY TO GIVE ICE/DEBRIS REPORT. 16-0467 CICE NTD DETAILED ENGINEERING REPORT OF FINAL 232 INSPECTION WILL NOW BE GIVEN ON CHANNEL 245. NOTE PERFORM NEXT STEP IF SS WATER TANK REQUIRED TOP-OFF. TOP-OFF SS SYS COMPLETE ----------------------- 16-0468 -02H45M JBWC STM SS ELEVATED TANK TOP-OFF WSSA 111 COMPLETE. NOT PERFORMED ______ 787 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LAUNCH COMMIT CRITERIA VERIF ---------------------------- NOTE THIS VERIFICATION INCLUDES: - A REVIEW OF ALL VALID SYSTEM PARAMETERS FOR FAILURES/ UNFAVORABLE TRENDS. - A REVIEW OF ALL SYSTEM LOGS AND OPEN PAPER TO VERIFY NO CONSTRAINTS. - A VERIFICATION OF ALL SYSTEM OMRS. 16-0469 -02H45M NTD OTC VERIFY NO VIOLATION OF LAUNCH SU72806 232 TBC COMMIT CRITERIA. PTC STM *FLT *MIL SRO LPS CSPE PAYLOAD LAUNCH COMMIT CRITERIA ------------------------------ 16-0470 -02H45M PTC ALL VERIFY YOUR SYSTEM MEETS LAUNCH 134 COMMIT CRITERIA. FOR SPACEHAB: DLES _____ *STC _____ FOR IUS: | DLES _____ | AXTC _____ | ICTC _____ | | FOR OTHER: DLES _____ 788 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORBITER LAUNCH COMMIT CRITERIA ------------------------------ 16-0471 -02H45M OTC ALL VERIFY YOUR SYSTEM MEETS LAUNCH 212 COMMIT CRITERIA REQUIREMENTS FOR CREW BOARDING PHASE AT T-2H30M. CPLE ___ CHYD ___ CCSE ___ CAPU ___ CNSE ___ CHGD ___ CAFM ___ CISL ___ CMPS ___ CEPD ___ CMPL ___ CAFC ___ CSME ___ COFC ___ CECL ___ CGNC ___ CPVD ___ CDPS ___ CFCP ___ CODS ___ CGSS ___ CCME ___ COOS ___ ET/SRB LAUNCH COMMIT CRITERIA ----------------------------- 16-0472 -02H45M TBC ALL VERIFY YOUR SYSTEM MEETS LAUNCH 136 COMMIT CRITERIA REQUIREMENTS CLOX _____ CPWR _____ CLHY _____ CBHY _____ CISL _____ CBRS _____ CMEC _____ 16-0473 CEPD CURSOR CNTL (VWC10) GRD SYS S/R HI XMIT CURSOR KEY - PRESS CRT (VWC10) VERIFY PIC SAMPLE RATES CHANGED TO 100/SEC 789 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SUPPORT LAUNCH COMMIT CRITERIA ------------------------------ 16-0474 -02H45M STM JSTC VERIFY REQUIRED LAUNCH COMMIT JSTC 111 JBFX CRITERIA VALID. WSSA GYCC COMM NET QBSE STSA | 104 GYCC GOIS 117 16-0475 JSTC JSEP VERIFY REQUIRED LAUNCH COMMIT ELEC 114 JSAC CRITERIA VALID. AC GSPN PNU JFIR FIRE *SEC SEC REPORT LCC STATUS ----------------- 16-0476 -02H40M OTC NTD NO LAUNCH COMMIT CRITERIA TBC VIOLATIONS. STM LPS *FLT *MIL SRO CSPE PTC 232 790 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PERSONNEL WITHIN LAUNCH IMPACT ------------------------------ AREA ON STATION --------------- 16-0477 STM JPHO VERIFY SUPPORT PERSONNEL ON FIRE 111 JSTC STATION WITHIN LAUNCH IMPACT PNU GYCC AREA. COMM JSTC JFIR GSPN GYCC WYVS PTP 16-0478 -02H40M JPHO STM ALL SUPPORT PERSONNEL REQUIRED COMM JSTC WITHIN LAUNCH IMPACT AREA ARE ON JSTC GYCC STATION. 111 STM NTD 232 LANDING AIDS ACTIVATION ----------------------- NOTE PERFORM NEXT TWO STEPS AT L-5 HOURS. 16-0479 NTD STM START MSBLS POWER UP PER COMM 232 OMI Z3111. STM GYCC 111 GYCC FMLS 117 16-0480 LRD STM ACTIVATE PAPI, BALL/BAR, AND STROBE 135 LIGHTING SYSTEMS. STM JBEP 111 CREW COMPT READY FOR INGRESS ---------------------------- 16-0481 -02H40M ASP OTC CREW COMPARTMENT READY FOR CREW 212 INGRESS. 791 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SWITCH STBY-FEP'S TO RF ----------------------- 16-0482 OTC NTD VERIFY MILA ANTENNA ALIGNMENT 232 COMPLETE. 16-0483 -02H30M OTC CGLS SWITCH STANDBY FEP'S TO RF. SU72808 16-0484 LPS VERIFY PCM FEP BIT SYNCS IN PGM MODE. 16-0485 CGLS LPS VERIFY RF SIGNAL PRESENT AT 127 GPCA/S, OIA/S, AND PLDA/S FEPS SCOPES. 16-0486 CGLS VERIFY 1 OC TASK AVAILABLE FOR $PCMS OPERATIONS. 16-0487 CGLS CONSOLE KYBD SLPP1 PERFORM PGM KEY - PRESS (KSCA OR KSCB) XMIT RESP VFY INTG MENU PFPK7 - PRESS PFPK6 (GLS CONTROL) - PRESS VFY GLS ML/MS DISPLAY (SDP01) 16-0488 CGLS CURSOR CNTL APP PG-B (SLPP1) RF SWITCH SELECT XMIT CURSOR KEY - PRESS 16-0489 CGLS APP PG A VERIFY PCMS OPERATIONS 16-0490 CGLS LPS AWP01 PG-B 127 VERIFY OIS, GPCS ARE ON SOURCE 2 HI RATE VOICE YES AND DATA IS VALID 792 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0491 CGLS CURSOR CNTL TERMINATE XMIT CURSOR KEY - PRESS CRT VFY INTG MENU CURSOR CNTL TERMINATE XMIT CURSOR KEY - PRESS CRT VFY SLPP1 INACTIVE 16-0492 CGLS OTC STANDBY FEP'S SWITCH TO RF. 212 COMPLETE. 16-0493 LPS JRPS CONFIGURE 192 KB JSC OD DATA (SKR) TO KMTS B SYSTEM. | 16-0494 LPS JRPS VERIFY KMTS 0505A2 (A5, KMTS B LINK) READING 192 KB AND LOCKED ON SIGNAL. 16-0495 LPS C1SE CONFIGURE VSB TO SOURCE 2, 192KB DATA PER OMI C2000 AND VERIFY SUCCESSFUL OPERATION. RETURN TO SOURCE 1 WHEN COMPLETE. 16-0496 LPS C1MC CONFIGURE PLDS FEP, IF SUPPORTING, 127 TO SOURCE 2, 192KB DATA VIA AWP01 AND VERIFY SUCCESSFUL OPERATION. NOT PERFORMED ______ 793 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0497 LPS VERIFY RPS P/B CONFIGURED TO SUPPLY 60KB R.F. DATA TO SOURCE 2 OF ME 1/2/3 AND SIGNAL PRESENT ON ME FEPS SCOPES. PDL PLAYBACK TO MSFC -------------------- NOTE PERFORM NEXT TWO STEPS IF REQUIRED BY MSFC. 16-0498 LPS JRPS CONFIGURE KMTS 0505A1 (A7,A8,A9) BIT SYNCS TO SOURCE 2 FOR PDL CHECKOUT (SOURCE 2, MANUAL MODE, 60 KB). NOT PERFORMED ______ 16-0499 LPS JRPS PDL CHECKOUT COMPLETE. CONFIGURE KMTS 0505A1 (A7,A8,A9) BIT SYNCS TO SOURCE 1 (SOURCE 1, MANUAL MODE, 60 KB). NOT PERFORMED ______ NOTE PERFORM NEXT STEP FOR MISSIONS THAT REQUIRE TEHM PDI DATA FLOW DURING ASCENT. 16-0500 PTC DSWF CONFIGURE RTP FOR 192 KB DATA AND 134 ZLPS VERIFY SUCCESSFUL TRANSITION. NOT PERFORMED ______ 794 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE | | PERFORM NEXT TWO STEPS | FOR IUS MISSION (STS-93). | | PAYLOAD ASCENT TELEMETRY LOCKUP | ------------------------------- | | 16-0501 -02H30M PTC DSWF VERIFY IUS ASCENT TELEMETRY STILL | 134 LOCKED UP. | | NOT PERFORMED ______| | NOTE | | PERFORM NEXT STEP IF IUS | ASCENT TELEMETRY IS NOT | LOCKED UP. | | 16-0502 PTC DSWF PERFORM IUS ASCENT TELEMETRY | 134 LOCKUP PER S0007VL4 (SEQ 81). | REPORT COMPLETION. | | NOT PERFORMED ______| | 795 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONTROL LOGIC INHIBIT --------------------- 16-0503 OTC CGLS PERFORM PROGRAM SAP92 FOR SU72810 212 T-2H30M REACTIVE CONTROL LOGIC INHIBIT, RCL STATUS, COMMAND ISSUANCE, STATUS DP/DA. (30 MIN) 16-0504 CGLS VERIFY 1 AVAILABLE CONCURRENCY AND 2 CONSECUTIVE OC TASKS. HOME CMD KEY - PRESS SAP92 PERF PGM KEY - PRESS 16-0505 CGLS PFP SAP92 - PRESS PFPK1 (STATUS CMD ISSU) - PRESS 16-0506 CGLS PFPK2 (STATUS DP/DA) - PRESS 16-0507 CGLS PFPK5 (T-2H5M RCL INHB) - PRESS 16-0508 CGLS PFPK6 (T-2H5M RCL STATUS) - PRESS NOTE PRESS FORM FEED ON PRINTER TO ENSURE ALL OUTPUT IS RECEIVED. RETRIEVE OUTPUT FROM CONSOLE PRINTER AND REVIEW FOR PROPER CONFIGURATION. 16-0509 CGLS TERMINATE SAP92 PFK15 - PRESS 16-0510 CGLS OTC COMPLETED IMPLEMENTATION OF 212 SAP92. OTC NTD 232 796 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ER OPEN LOOP CMD TEST COMPLETE ------------------------------ 16-0511 SRO NTD COMMAND AUTO CARRIER SYSTEM CHECKS 232 COMPLETE. ET LIQUID LEVEL SENSOR CHECKS ----------------------------- DURING REPLENISH ---------------- NOTE LOX AND LH2 MUST BOTH BE IN STABLE REPLENISH BEFORE LIQUID LEVEL SENSOR CHECK CAN BE RUN. 16-0512 -02H30M NTD OTC PERFORM ET LIQUID LEVEL SENSOR SU72812 232 TBC CHECKS DURING REPLENISH PER OTC CMPS OMI S1004 (15 MIN). 212 TBC CLOX 136 CLHY 797 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB MDM CD VERIF ---------------- NOTE DO NOT PROCEED WITH SRB MDM CD VERIF UNTIL AFTER RESUMING THE COUNT AT T-3H00M. NOTED REQUIREMENTS SATISFIED BY THE FOLLOWING STEPS. OMRS S00FE0.185-1R OMRS S00FE0.225-A-1R OMRS S00FE0.225-B-1R OMRS S00FE0.230-A-1R OMRS S00FE0.230-B-1R 16-0513 -02H30M NTD TBC PERFORM SRB MDM COUNTDOWN SU72814 232 VERIFICATION. (15 MIN) TBC CBDP 136 NOTE SRB MDM I/O ERRORS CAN OCCUR DURING MDM P/S SEPARATION. 16-0514 CBDP CURSOR CNTL (SAS05 PG B) DPS XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS05 PG B) SRB MANUAL TEST SEL XMIT CURSOR KEY - PRESS PFK2 KEY - PRESS 16-0515 CBDP CURSOR CNTL (BSM06 PG B) COUNTDOWN TEST XMIT CURSOR KEY - PRESS CRT (BSM06 PG B) VERIFY ALL ENTRIES TO TEST STATUS DISPLAY 'OK' GREEN 798 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0516 CBDP PFP (BSM06) PFPK6 KEY - PRESS (SYSTEM STATUS) CRT (BSM06 PG B) ALL MDM P/S SEP SWITCHES - ON 16-0517 CBDP PFP (BSM06) PFPK1 KEY - PRESS (TERMINATE) 16-0518 CBDP TBC SRB MDM COUNTDOWN VERIFICATION 136 COMPLETE. TBC NTD 232 16-0519 NOTED REQUIREMENTS COMPLETE. OMRSD S00FE0.185-1R OMRSD S00FE0.225-A-1R OMRSD S00FE0.225-B-1R OMRSD S00FE0.230-A-1R OMRSD S00FE0.230-B-1R ASTROVAN AT PAD --------------- 16-0520 -02H30M *AVN NTD ASTROVAN AT PAD SURFACE. SEC NET ESCORT VEHICLE RETURNING TO SU72777 105 A/B-11 ROADBLOCK. NTD OTC 232 *SCC *PAC FLIGHT CREW AT FSS ------------------ 16-0521 FLT FLIGHT CREW AND SUIT TECH CREW PROCEED TO FSS 195 FT LEVEL. NST 16-0522 OTC NTD REQUEST CONCURRENCE TO PROCEED SU72779 232 WITH CREW INGRESS. 16-0523 -02H30M NTD OTC PROCEED WITH CREW INGRESS 232 OPERATIONS WHEN CREW ARRIVES. OTC OVCC 212 799 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACID DEPOSITION WX BRIEFING --------------------------- 16-0524 -02H25M STM CBSE VERIFY READY FOR ACID DEPOSITION SU72815 163 WEATHER BRIEFING ON OIS CH 131. 221 *SCC 16-0525 STM EEC PERFORM ACID DEPOSITION WEATHER 131 BRIEFING. ASTROVAN - DEPART PAD --------------------- 16-0526 -02H25M *AVN NTD ASTROVAN CLEARED PAD SURFACE, SEC NET PROCEEDING TO A/B-11 ROADBLOCK. 105 NTD *SCC 232 STM FLT CREW INGRESS ---------------- 16-0527 -02H25M OVCC OTC FLIGHT CREW HAS ARRIVED AT SU72781 212 ORBITER, CREW INGRESS IN WORK AT THIS TIME. 16-0528 OTC ALL FLIGHT CREW INGRESS PROCEEDING 212 AT THIS TIME. MONITOR CONSOLE DISPLAYS. 16-0529 NTD STM TERMINATE VIDEO TRACKING AND COMM 232 RECORDING OF FLIGHT CREW. OTV STM JYVO CAMERAS AND VIDEO RECORDERS 138 JYVR RELEASED TO PREVIOUSLY ASSIGNED USAGE. OTV CAMERA 005/105 TO MONITOR CREW HATCH. (SEE JYVO FIGURE 4). 800 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CDR/PLT SEAT AIDED INGRESS -------------------------- NOTE DURING 1NGRESS SUIT FANS WILL BE POWERED UP, COMM SWITCHES ON L5 AND R6 WILL BE TURNED ON, SEATS WILL BE ADJUSTED AND COMM CHECKS WILL BE PERFORMED WITH OTC, NTD, AND *FLT. 16-0530 -02H25M OTC RECORD INGRESS TIME: CDR __________GMT PLT __________GMT IMU PREFLIGHT CAL CONTINGENCY COMPLETE -------------------------------------- NOTE PERFORM NEXT STEP IF IMU PREFLIGHT CAL CONTINGENCY WAS REQUIRED. 16-0531 -02H25M CGNC OTC IMU PREFLIGHT CAL CONTINGENCY COMPLETE. 132 NOT PERFORMED ______ 801 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IMU'S TO TERM IDLE ------------------ NOTE PERFORM NEXT STEP IF IMU IN GC ALIGN 1. 16-0532 -02H25M OTC CGNC TAKE IMUS TO TERM/IDLE PER IMU SU72816 212 GYROCOMPASS ALIGNMENT SEQUENCE OF OMI V1123. REPORT COMPLETION. (3 MIN) RT OMI LOG NO.__________ NOT PERFORMED ______ IUS RIMU CAL ALIGN COMPLETE | --------------------------- | (CONTINGENCY) | ------------- | | NOTE | | PERFORM NEXT STEP FOR | IUS MISSION (STS-93). | | PERFORM NEXT STEP IF | CONTINGENCY CAL AND ALIGN | WAS INITIATED. | | 16-0533 -02H20M ICTC PTC IUS RIMU CAL AND ALIGN COMPLETE. | 134 IUS IS NOW IN GYRO COMPASS MODE. | PTC NTD QUIET TIME NO LONGER REQUIRED. | 232 | | OMRS P018JC.010 | OMRS P018JB.035-C | | NOT PERFORMED ______| 802 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IRAMS ACTIVATION FOR IMU GYROCOMPASS ------------------------------------ ALIGN ----- 16-0534 -02H20M OTC CGNC PERFORM IRAMS PAPAS INVOCATION. SU72817 212 16-0535 CGNC CONSOLE KYBD CDS ENABLE KEY - PRESS (SIGN ON TO HI-TRX SUPPORTING CURRENT TEST) TXKA (WHERE A = Q OR R) SIGN ON KEY - PRESS 16-0536 CGNC CONSOLE KYBD BREAK KEY - PRESS ?(IRM)# CDS XMIT KEY - PRESS BREAK KEY - PRESS ?PAPAS (TCID) DLA001 (STSXXY);HHMMSS# (CURRENT GMT TIME) (WHERE STSXXY IS PARAMETER FILE NAME FROM IMU DATA BOOK) 16-0537 CGNC CONSOLE KYBD ?Y# CDS XMIT KEY - PRESS 16-0538 CGNC CRT (IRAMS) VERIFY MESSAGE: BEGINNING DATA RETRIEVAL 803 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE IRAMS RESULTS SHOULD BE MONITORED AT THE FOLLOWING | POINTS: 1. AT END OF GA POS 2 2. AT END OF EACH MEASUREMENT PERIOD OF GYROCOMPASS ALIGN-1 (GA-1) USE THE FOLLOWING STEPS | TO VIEW IRAMS DATA: | CDS ENABLE KEY - PRESS TXKA (WHERE A = Q OR R SUPPORTING IRAMS) SIGN ON KEY - PRESS BREAK KEY - PRESS ?(IRM)# CDS XMIT KEY - PRESS IRAMS SCREEN WILL APPEAR AFTER A BRIEF DELAY. PERFORM NEXT STEP TO SIGN OFF IRAMS. IRAMS CAN ONLY BE TERMINATED BY KEYBOARD ENTRY OF "PAPAK" WHEN SIGNED ONTO HI-TRX UNDER LOGICAL ID "IRM". 804 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0539 CGNC CONSOLE KYBD CPU ENABLE KEY - PRESS GMT AND MET DELTA ADJUST ------------------------ NOTE THE FOLLOWING IMU AND GMT DELTA ADJUST OPERATIONS ARE TIME AND SEQUENCE CRITICAL. IMU'S MUST BE IN TERM/IDLE FOR GMT/MET ADJUST. | IF IUS RIMU CONTINGENCY | ALIGN IS IN PROGRESS, | WAIT UNTIL COMPLETE PRIOR | TO PROCEEDING WITH GMT/MET | DELTA ADJUST (IUS MISSIONS | ONLY). | 16-0540 CGNC OTC READY FOR GMT DELTA ADJUST. SU72818 212 | 16-0541 -02H20M OTC NTD PROCEEDING WITH ORBITER GMT AND 232 MET DELTA ADJUST. NTD PTC | PTC ICTC | 134 | 805 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE OIS FEP MAY GIVE A "NO-GO" INDICATION FOR 1-2 SECS DURING DELTA ADJUST. GMT ADJUST MUST NOT BE DONE WHILE IMU PRE-FLIGHT CAL, ATT DET OR PRE-FLIGHT ALIGN ARE IN WORK. IMUS MUST BE IN TERM/IDLE FOR GMT ADJUST. 16-0542 -02H20M OTC CDPS PERFORM GMT AND MET ADJUSTMENT 212 CISL PER S0007VL4 (SEQ 49) ITEM 18 ON CH 152. (10 MIN) OMRS S00FG0.085 VERIFY ASTROVAN POSITION ------------------------ 16-0543 -02H15M *AVN NTD ASTROVAN AND SECURITY ESCORT SEC NET HAVE CLEARED BACK TO A/B-11 105 ROADBLOCK. NTD *SCC 232 ET LIQUID LEVEL SENSOR CHECKS COMPLETE -------------------------------------- 16-0544 -02H15M CMPS OTC ET LIQUID LEVEL SENSOR CHECKS SU72812 212 DURING REPLENISH COMPLETE PER OTC NTD S1004. 232 NTD TBC TBC CLOX 136 OMRSD S00FF0.204-1R 806 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE MIDDECK FLIGHT CREW SEAT AIDED INGRESS PROCEEDS IN PARALLEL WITH POST INGRESS SW RECONFIGURATION. POST INGRESS SW RECONFIGURATION -------------------------------- WARNING NEXT TWO STEPS MUST BE COMPLETE BEFORE PROCEEDING WITH RJD DRIVER SWITCH ACTIVATION. NOTE NOTED REQUIREMENT IS SATISFIED BY THE FOLLOWING STEPS ANNOTATED WITH OMRS CODE. OMRS S00FF0.235-1R RCS CMD STATUS TEST ------------------- 16-0545 -02H15M COFC PFP (SAB20) PFPK1 - PRESS (RCS CMD TEST) 16-0546 COFC CRT (SWB02 PG-B) VERIFY RJD CMD STATUS TEST SUCCESSFUL OMRS V79GEN.400 OMRS S00FF0.235-1R (VTB09) 16-0547 -02H10M COFC OTC PROCEED WITH POST INGRESS SWITCH 212 RECONFIGURATION. 16-0548 -02H10M OTC ASP PERFORM POST INGRESS SWITCH RECONFIGURATION AND SWITCH GUARD REMOVAL PER YOUR CHECKLIST. 807 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0549 ASP PANEL O14 ROW F RJDA 1A L2/R2 MANF DRIVER SW - ON RJDA 2A L4/R4 MANF DRIVER SW - ON RJDF 1B F1 MANF DRIVER SW - ON L OMS ENG VLV SW - ON 16-0550 ASP PANEL O15 ROW F RJDA 1B L1/R1 MANF DRIVER SW - ON RJDF 1A F2 MANF DRIVER SW - ON NOTE RJD MANF L5/F5/R5 DRIVER SWITCH TO "ON" WILL BE PERFORMED "ON-ORBIT" 16-0551 ASP REMOVE RJD MANF L5/F5/R5 DRIVER SWITCH GUARD. 16-0552 ASP PANEL O16 ROW F RJDA 2B L3/R3 MANF DRIVER SW - ON RJDA 2A F3 MANF DRIVER SW - ON RJDF 2B F4 MANF DRIVER SW - ON R OMS ENG VALVE SW - ON 16-0553 ASP PANEL O6 GPC 5 OUTPUT SW - BACKUP 808 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0554 ASP PANEL A7U REMOVE TV CAMERA POWER AND TV CONTROL POWER SWITCH GUARDS (KEY REQUIRED) 16-0555 -02H10M ASP OTC POST INGRESS SWITCH RECONFIGURATION 212 COMPLETE. CAUTION AND WARNING ALARM OTC CISL VOLUME WILL BE ADJUSTED, MASTER ALARM WILL BE INTENTIONALLY TRIPPED. (PARAM 099) CAUTION AND WARNING VOLUME ADJUST --------------------------------- NOTE CREW WILL ADJUST COMM VOLUME AS REQUIRED FOR SATISFACTORY COMM/ MASTER ALARM LEVEL. DO NOT PERFORM NEXT FOUR STEPS FOR SCRUB/TURNAROUND RUN. 16-0556 ASP PANEL R13U SU72783 CAUTION/WARNING PARAM SEL T/W'S - 099 PARAM SW - INHIBIT, REL PARAM SW - ENABLE, REL VERIFY C&W MASTER ALARM NOT PERFORMED ______ 16-0557 FLT HIU CREW ADJUST COMM VOLUME AS REQUIRED FOR SATISFACTORY COMM/MASTER ALARM LEVEL. NOT PERFORMED ______ 16-0558 CDR PANEL F2 MASTER ALARM PB - PRESS, REL VERIFY MASTER ALARM LIGHT - OFF ASP PANEL R13U CAUTION/WARNING PARAMETER SELECT TW'S - 120 NOT PERFORMED ______ 809 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0559 ASP OTC C/W VOLUME ADJUST COMPLETE. 212 OTC CISL NOT PERFORMED ______ ACTIVATE RJD DRIVER LCC EMON ---------------------------- 16-0560 COFC APPL PG A (SAB20/SWB02) PFK13 KEY - PRESS(ACT EMON SETUP) 16-0561 COFC CURSOR CONTROL (SAB20/SWB02 PG A) A-RJD DRIVER XMIT CURSOR KEY - PRESS OMRS S00FF0.235-1R (SWB02) 16-0562 NOTED REQUIREMENT COMPLETE. OMRSD S00FF0.235-1R 16-0563 COFC APPL PG A (SAB20/SWB02) PFK13 KEY - PRESS(DE-ACT EMON SETUP) 810 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PS/MS SEAT AIDED INGRESS ------------------------ CAUTION PRIOR TO CONNECTING HELMET COMM LEAD TO HIU, COMM CCU POWER TO MO39M OR A11 NEEDS TO BE VERIFIED OFF. NOTE DURING CREW INGRESS, SUIT FANS WILL BE POWERED UP AND COMM CHECKS WILL BE PERFORMED WITH OTC, NTD AND *FLT. 16-0564 OTC RECORD INGRESS TIME ONLY FOR APPLICABLE CREW MEMBERS. PS1__________GMT PS2__________GMT PS3__________GMT MS1__________GMT MS2__________GMT MS3__________GMT MS4 _________GMT 811 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GMT AND MET DELTA ADJUST COMPLETE --------------------------------- 16-0565 -02H10M CDPS OTC GMT DELTA WAS __________ MS. SU72818 | 212 GMT ADJUSTMENT __________ WAS/WAS NOT | OTC PTC PERFORMED | | MET DELTA WAS __________ MS. | MET ADJUSTMENT __________ WAS/WAS NOT | PERFORMED. | | GMT AND MET ADJUST COMPLETE. | READY FOR IMU PLATFORM | POSITIONING. OMRSD S00FG0.085 | NOTE | | PERFORM NEXT STEP FOR | IUS MISSION (STS-93). | | 16-0566 PTC ICTC ORBITER GMT AND MET DELTA ADJUST | 134 COMPLETE. GMT ADJUST WAS/WAS NOT | PERFORMED. | | NOT PERFORMED ______| 812 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IMU PLATFORM POSITIONING FOR ---------------------------- GYROCOMPASS ALIGN ----------------- 16-0567 -02H04M CGNC CRT (VABM1/VSB78 PG B) SU72820 VERIFY PLATFORM POSITIONING IN PROGRESS GLS INITIALIZATION ------------------ 16-0568 -02H00M OTC CGLS PERFORM GLS INITIALIZATION PER SU72821 212 SEQ 62 (S0007VL4) ON OIS CH 162. 16-0569 CGLS OTC FEP DUAL INTERRUPT NOTIFICATION WILL BE ACTIVATED MOMENTARILY AND MAY CAUSE REANNUNCIATION OF ERROR MESSAGES AT SYSTEMS CONSOLES FOR INTERRUPT MONITORED PARAMETERS CURRENTLY OUT OF GLS LIMITS. 16-0570 CGLS CURSOR CNTL (SAP10) TERM XMIT CURSOR KEY - PRESS SYS TERM (LEAVING SW SCAN ACT) XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY SAP10 AND SAP27 TERMINATE 813 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RETRIEVAL AREA - STATUS CHECK ----------------------------- 16-0571 -02H00M LRD BRD REPORT STATUS IN RETRIEVAL 135 AREA: 1. SHIPS ON STATION 2. SRB IMPACT AREA CLEAR OF OTHER VESSELS 3. WEATHER STATUS WEATHER STATUS IN RETRIEVAL AREA IS AS FOLLOWS: SEA STATE __________ SEA TEMP __________ AIR TEMP __________ WINDS __________ VISIBILITY __________ 16-0572 -02H00M LRD SRO SRB IMPACT AREA CLEAR (OR NOT 135 CLEAR) OF VESSELS OTHER THAN REQUIRED RETRIEVAL SHIPS. 814 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RTLS RUNWAY ----------- 16-0573 -02H00M LSO LRD IN EVENT OF RTLS LANDING WILL JSTC LF1 BE ON RUNWAY ______ (15 OR 33). SLF LRD STM FIRE 135 SLF AOA SITE SELECTION IS__________. SEC ROC (KSC, DFRC, WSSH) *SCC EMS STM JSTC 111 GYCC JSTC FSTC 114 FSAM JFIR *SEC 16-0574 LRD NCC IN EVENT OF RTLS ABORT, LANDING CCN WILL BE ON RUNWAY _____ (15 OR 33). AOA SITE SELECTION IS__________. (KSC, DFRC, WSSH) 16-0575 OTC AOTC CONFIGURE OISD FOR PURGE SU72788 NET (9033) AND PERFORM COMM CHECK WITH OPS AT SLF. 815 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OAA ACCUMULATOR FORCED CHARGE ----------------------------- 16-0576 -02H00M OTC CGSS PERFORM OAA ACCUMULATOR FORCED SU72822 212 CHARGE. 16-0577 -02H00M CGSS PFP (VAJ02) PFPK-3 VAJ07 OAA ACCUM - PRESS PFPK-5 OAA ACCUM EXECUTE - PRESS VERIFY OAA ACCUM TOP AND BOTTOM LITES ON, THEN OFF. 16-0578 CGSS OTC OAA ACCUMULATOR FORCED CHARGE COMPLETE. SRB HPU GAS GENERATOR HEATER ON -------------------------------- 16-0579 -02H00M TBC CBHY TURN ON SRB HPU GAS GEN HEATERS. SU72823 136 16-0580 -02H00M CBHY CURSOR CNTL VEHCLE GAS GENRTR - AUT 16-0581 -02H00M CBHY CRT (BAT04) VEHCLE GAS GENRTR P TEMP VERIFY ALL FOUR GAS GENERATOR BED TEMPERATURES ARE INCREASING. (MINIMUM OF 2.0 DEG F/MINUTE AVERAGE RISE IN ONE HOUR) OMRSD S00FF0.170 16-0582 CBHY TBC SRB HPU GAS GEN HEATERS ON 136 TBC NTD 232 16-0583 -02H00M TBC CBHY DURING REMAINDER OF COUNT UNTIL 136 T-1 MIN, CBHY TO MONITOR AND ADJUST ALL GAS GENRTR TEMP(S) AT 190 TO 248 DEG F BY ON/OFF HTR CMD 1 (CURSOR CNTL) AND/OR ON/OFF HTR CMD 2 (CURSOR CNTL) AND/OR HIGH/LOW SOFTWARE LIMIT ADJUSTMENTS. 816 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLOSE VAB HIGH BAY AND TRANSFER ------------------------------- AISLE DOORS ----------- 16-0584 -02H00M STM JCTL CLOSE ALL VAB HIGH BAY AND CDPA 111 TRANSFER AISLE DOORS (Q3011, JCTL VCMP Q3016). (1 HR) 16-0585 OTC CBSE IF DATA AVAILABLE, VERIFY V67V0100 212 RECEPTION OF BIO-MED DATA. V67V0200 NOT PERFORMED ______ 16-0586 -02H00M OTC RSRT LOAD NEW TAPES FOR RANGE SAFETY 212 MONITOR STATION RACK 8234 TO SUPPORT TERMINAL COUNTDOWN. ENSURE VCR'S ARE SET TO RECORD. T:______ SRM CHAMBER PRESSURE VERIFICATION --------------------------------- 16-0587 TBC CISL PERFORM SRM CHAMBER PRESSURE SU72819 136 VERIFICATION PER S0007VL4 (SEQ 38) ON OIS CH 145. (35 MIN) FIRST MOTION (SIM) SIGNAL TEST ------------------------------ 16-0588 -02H00M STM SRO VERIFY READY TO RECEIVE FIRST SU72824 111 MOTION (SIMULATED) SIGNAL AT T-01H55M BY COUNTDOWN CLOCK. 16-0589 -02H00M STM NTD FIRST MOTION (SIMULATED) SIGNAL 232 WILL BE SENT OVER JSC COUNTDOWN NTD *FLT SYSTEM T-01H55M BY COUNTDOWN CLOCK. 817 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE LAUNCH POLYNOMIAL UPLINKS CAN BE PERFORMED DURING IMU ATT DET AND PREFLT ALIGNMENT. DOWNLIST DUMPS CAN BE PERFORMED DURING ATT DET AND PREFLT ALIGNMENT DURING NONCRITICAL PERIODS WHEN LOSS OF DOWNLIST CAN BE TOLERATED. IMU ATT DET ----------- 16-0590 -01H57M CGNC CRT (VABM1/VSB35 PG B) SU72825 VERIFY IMU ATT DET IN PROGRESS 16-0591 STM JTCR VERIFY FIRST MOTION SYSTEM 111 CONFIGURED TO RECEIVE PAD ___ FIRST MOTION SIGNAL. 16-0592 STM JTCR SEND AND DISTRIBUTE SIMULATED 111 FIRST MOTION SIGNAL AT T-01H55M BY THE CLOCK. 16-0593 -01H55M JTCR (SIMULATED) FIRST MOTION SIGNAL - EXECUTE 16-0594 -01H55M STM SRO VERIFY (SIMULATED) FIRST MOTION 111 SIGNAL RECEIVED BY ALL STATIONS STM NTD REQUIRED. REQUEST PERMISSION TO 232 REMOVE (SIMULATED) SIGNAL AND NTD *FLT RECONFIGURE TO PAD. 16-0595 STM JTCR RELEASE (SIMULATED) FIRST 111 MOTION SIGNAL AND RECONFIGURE FIRST MOTION DISTRIBUTION SYSTEM TO RELAY SIGNAL FROM THE PAD. PERFORM MASTER RESET ON JSC COUNTDOWN CONVERTER. 16-0596 STM NTD FIRST MOTION (SIM) SIGNAL 232 TEST COMPLETE. 818 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SLF NAVAID STATUS ----------------- 16-0597 STM GYCC VERIFY MSBLS/TACAN READY TO COMM 111 SUPPORT. GYCC FMLS 117 FTAC 16-0598 JBEP STM PAPI, BALL/BAR, AND STROBE PWRA 111 LIGHTING SYSTEMS OPERATIONAL AND READY TO SUPPORT. 16-0599 -01H55M *SLF LRD PERFORM FOLLOWING: 135 LRD LSO 1. KSC AND/OR PAFB TACAN OPERATIONAL LF1 AND READY TO SUPPORT LAUNCH. 2. KSC MSBLS OPERATING AND READY TO SUPPORT LAUNCH. LANDING AIDS STATUS ------------------- 16-0600 STM LRD MSBLS, TACAN (KSC), PAPI, BALL/BAR 135 AND STROBES ACTIVATED AND READY TO LRD NCC SUPPORT. CCN LRD LSO LF1 LRD CHECKS ---------- 16-0601 -01H55M LRD EMS VERIFY YOU ARE READY TO SUPPORT 135 *DCD RTLS RESCUE/MEDICAL OPERATIONS. ROC S0028 CTS______ PREDEPLOY BRIEFING______ CONVOY DEPLOY______ TRIAGE SITE HELIPAD______ RTLS RUNWAY______ 16-0602 -01H50M NTD SRO PERFORM ER SRSS VERIFICATION SU72826 232 TEST. 819 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IMU GYROCOMPASS ALIGNMENT ------------------------- NOTE DO NOT PROCEED WITH IMU GYROCOMPASS ALIGNMENT UNTIL DPS GMT/MET DELTA ADJUST IS COMPLETE. THIS MAY OCCUR OUT OF THE NOMINAL TIMELINE DUE TO AN IUS RIMU ALIGNMENT. 16-0603 -01H50M NTD *FLT VERIFY READY FOR IMU PRE-FLIGHT SU72827 232 OTC ALIGN. 16-0604 -01H47M OTC CGNC CRT (VABM1/VSB35 PG B) VERIFY IMU GYROCOMPASS ALIGN IN PROGRESS FUEL CELL PURGE --------------- 16-0605 -01H40M OTC CFCP PERFORM FUEL CELL PURGE PER SU72828 212 S0007VL4 (SEQ 47) ON OIS CH 153. REPORT COMPLETION. OMRS V45CH0.040 16-0606 CFCP OTC FUEL CELL PURGE COMPLETE. 212 OMRSD V45CH0.040 16-0607 -01H35M COOS CRT (VWD73) VERIFY LOMS ENG VLV ON V43S4575E1 ROMS ENG VLV ON V43S5575E1 820 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CREW MODULE CLOSEOUT OPS ------------------------ 16-0608 -01H35M OTC ALL VERIFY ALL SYSTEMS READY FOR SU72785 212 CREW MODULE CLOSEOUT. 16-0609 -01H35M OTC ASP CLOSE OUT CREW MODULE FOR FLIGHT 212 PER YOUR CHECKLIST. INSPECT CM FOR ANY NON FLIGHT ITEMS. REMOVE AND REPORT ADDITIONAL ITEMS FOUND. 1. RCS DRIVER AND OMS ENGINE SWITCHGUARDS 2. SWITCHGUARD LOCKS 3. SWITCHGUARD KEYS 4. VISOR PROTECTORS (1 PER CREW MEMBER) 5. FLIGHT DATA FILE STOWAGE BAGS (1 PER CREW MEMBER) 6. NST CHECKLIST (1) 7. NST PERSONAL EQUIPMENT TRANSFER BAG (1) 8. ASP BOOK 9. ASP EQUIPMENT TRANSFER BAG (1) 10. HUD COVERS (G070-011260-001 1 SET (2 COVERS) 11. RHC COVERS (LH AND RH) (2) 12. RMS RHC COVER (IF INSTALLED) 13. FLT DECK PROTECTIVE FLOORING 14. EMERGENCY EGRESS BREATHING DEVICE (EEBD) (2) 15. WMC AV BAY 3B PROTECTIVE COVERS (4) (EXCEPT 5 FOR OV-104) 16. BUMPER PAD ASSY (ON ESCAPE POLE MAGAZINE) 17. AIRLOCK EXTERIOR PROTECTIVE PADS (OV-102 ONLY) 18. AIRLOCK HATCH PROTECTIVE COVER (G070-502009-001) (OV-102 ONLY) 19. CCTV MONITOR COVER (G070-011312- 004) OR FOAM PAD 20. W9 AND W10 STAND-ON COVERS 21. A11 PROTECTIVE COVERS (EXCEPT OV-103) 22. A15 PROTECTIVE COVERS 23. AV BAY 3B GPS PANEL PROTECTIVE COVER (SA-096-086-101) AND LEG SUPPORT PANEL G070- 502030-001 (OV103 AND 105 ONLY) 821 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0609 NOTE CON'T ITEMS 24 AND 28 ARE NOT INSTALLED ON OV-102. 24. G076-500301-001 LOCKER BRACKET ASSYS (2) 25. G076-500304-001 LOCKER BEAM ASSY (LONG) 26. G076-500300-001 MIDDECK PANEL ASSY 27. G076-500300-002 MIDDECK PANEL ASSY 28. G076-500308-001 LADDER SUPPORT LEG ASSYS (2) TNW:____ 16-0610 ASP OTC CM/MD INSPECTION COMPLETE. ALL 212 NON FLIGHT ITEMS HAVE BEEN REMOVED. 16-0611 OTC ASP VERIFY ASCENT CAMERA CONFIGURATION 212 AND SETUP COMPLETE. LCC ASTRO COMM CHECK -------------------- 16-0612 -01H35M OTC CDR VERIFY EACH MEMBER OF FLT CREW SU72786 A/G1 READY TO PROCEED WITH ASTRO COMM CHECKS. 16-0613 OTC ALL ANY CONVERSATION ON OIS 212 CH 212 DURING ASTRO COMM CHECK WILL BE HEARD BY CREW. CHANNEL SHOULD REMAIN SILENT EXCEPT FOR EMERGENCY CALLS. 16-0614 OTC FLT DURING ASTRO COMM CHECKS ADJUST 212 CREW APPROPRIATE VOLUME CONTROL (A/G-1, A/G 2, ICOM A, ICOM B, A/A) FOR COMFORT. DO NOT CHANGE AUDIO PANEL SW CONFIGURATION. 16-0615 OTC PERFORM 2-WAY COMM CHECK WITH 212 EACH MEMBER OF FLT CREW ON A/G 1 (OIS CH 212). 16-0616 OTC ASTRO COMM-OIS INTERFACE PNL A/G 2 SW - ACTIVE VERIFY A/G 2 ACTIVE LITE ON 822 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0617 OTC PERFORM 2-WAY COMM CHECK WITH 213 EACH MEMBER OF FLT CREW ON A/G 2 (OIS CH 213). 16-0618 OTC ASTRO COMM-OIS INTERFACE PNL A/G 2 SW - MONITOR VERIFY A/G 2 MONITOR LITE ON ICOM-A SW - ACTIVE VERIFY ICOM-A ACTIVE LITE ON 16-0619 OTC PERFORM 2-WAY COMM CHECK WITH 214 EACH MEMBER OF FLT CREW ON ICOM A (OIS CH 214). 16-0620 OTC ASTRO COMM-OIS INTERFACE PNL ICOM-A SW - OFF VERIFY ICOM-A ACTIVE LITE OFF ICOM-B SW - ACTIVE VERIFY ICOM-B ACTIVE LITE ON 16-0621 OTC PERFORM 2-WAY COMM CHECK 215 WITH EACH MEMBER OF FLT CREW ON ICOM B (OIS CH 215). 16-0622 OTC ASTRO COMM-OIS INTERFACE PNL ICOM-B SW - OFF VERIFY ICOM-B ACTIVE LITE OFF UHF SW - ACTIVE VERIFY UHF ACTIVE LITE ON 16-0623 OTC PERFORM 2-WAY COMM CHECK WITH EACH MEMBER OF FLT CREW ON A/A (OIS 6311-FR1 OR 6331-FR3). 16-0624 OTC ASTRO COMM OIS INTERFACE PANEL UHF SW - MONITOR VERIFY UHF MONITOR LITE ON 16-0625 -01H30M OTC CDR ASTRO COMM CHECKS COMPLETE. 212 ALL PERSONNEL STANDBY FOR AIR OTC NTD TO GROUND VOICE CHECKS. 232 823 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MCC A/G VOICE CHECKS -------------------- 16-0626 -01H30M NTD *FLT CONDUCT A/G VOICE CHECKS. SU72787 232 16-0627 *FLT CDR CONFIGURE FOR A/G 1 VOICE CHECK. A/G1 PLT 16-0628 CDR PANEL O5 PLT LEFT AUDIO A/G 2 SW - OFF A/A SW - OFF PANEL O9 RIGHT AUDIO A/G 2 SW - OFF A/A SW - OFF 16-0629 *FLT PERFORM 2-WAY COMM CHECK WITH A/G1 CDR, PLT ON A/G 1. 16-0630 *FLT CDR CONFIGURE FOR A/G 2 VOICE CHECK. A/G1 PLT 16-0631 CDR PANEL O5 PLT LEFT AUDIO A/G 2 SW - T/R 1 SW - OFF PANEL O9 RIGHT AUDIO A/G 2 SW - T/R 1 SW - OFF 16-0632 *FLT PERFORM 2-WAY COMM CHECK WITH A/G2 CDR, PLT ON A/G 2. 16-0633 *FLT CDR CONFIGURE FOR A/A VOICE CHECK. A/G2 PLT 824 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0634 CDR PANEL O5 PLT LEFT AUDIO A/A SW - T/R A/G 2 SW - OFF PANEL O9 RIGHT AUDIO A/A SW - T/R A/G 2 SW - OFF 16-0635 *FLT PERFORM 2-WAY COMM CHECK UHF WITH CDR, PLT ON A/A. 16-0636 *FLT FLT CONFIGURE FOR SIMO VOICE CHECK. UHF CREW (LAUNCH CONFIG) 16-0637 CDR PANEL O5 PLT LEFT AUDIO A/G 1 SW - T/R 2 SW - T/R PANEL O9 RIGHT AUDIO A/G 1 SW - T/R 2 SW - T/R 16-0638 *FLT PERFORM 2-WAY COMM CHECK UHF WITH EACH MEMBER OF FLT CREW A/G1 ON A/G AND A/A SIMO. VERIFY D/L A/G2 VOICE ON A/G 1, A/G 2 AND UHF. OMRSD S00FG0.050-1R 16-0639 *FLT NTD A/G VOICE CHECKS COMPLETE. 212 16-0640 NTD OTC ASTRO COMM VOICE CHECKS COMPLETE. 232 OIS CH 212 IS AVAILABLE FOR NORMAL OTC ALL USE. 825 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RE-BOOT SPA/CLEAR SPOOLER ------------------------- 16-0641 LPS NTD SPA WILL BE RE-BOOTED TO CLEAR NTD OTC SPOOLER. SPA WILL BE OUT OF PA TBC OPERATION FOR APPROX 3 MINUTES. PTC 16-0642 LPS CPDR PERFORM SPOOLER CLEAR OPERATION. 16-0643 LPS NTD REQUEST CONCURRENCE FROM PAYLOAD 232 TEST CONDUCTOR TO INHIBIT HIM 6880 NTD PTC AT L-15M. RECORD CONCURRENCE/ NON-CONCURRENCE _____. CONTROLLABILITY LIGHT TEST -------------------------- 16-0644 -01H30M NTD SRO PERFORM CONTROLLABILITY LIGHT SU72829 232 *FLT TEST. 16-0645 SRO NTD CONTROLLABILITY LIGHT TEST 232 COMPLETED SATISFACTORILY. CLEAR SLF --------- 16-0646 -01H30M LRD *SEC COMMENCE CLEARING OF SLF SEC 135 (SEE FIG 6,) (1 HR). SU72830 16-0647 -01H30M *SEC LRD SLF CLEAR OF NONESSENTIAL SEC 135 PERSONNEL. 826 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ASP/NST1 - EGRESS FROM CREW --------------------------- MODULE ------ NOTE NEXT THREE STEPS WILL TERMINATE COMM BETWEEN ASP AND CONTROL ROOM, POWER UP MIDDECK CAMERAS (IF INSTALLED) AND POWER DOWN FUEL CELL MEASUREMENT SYSTEM (FCMS). 16-0648 ASP PANEL A15 PS COMM CCU PWR SW - OFF DISCONNECT COMM CABLE FROM PANEL A15 16-0649 OTC ASP PANEL MO58F TV PWR SW - ON NOT PERFORMED ______ 16-0650 ASP PANEL ML86B SU72838 | ROW D MN A PYRO JETT SYS A FC PCM CB - OPEN 16-0651 -01H25M OTC ASP EGRESS CREW MODULE. VERIFY 212 NST1 READY FOR HATCH CLOSURE. OVCC | 16-0652 OTC NTD READY FOR HATCH CLOSURE. | 232 | 827 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0653 CISL TBC SRM CHAMBER PRESSURE SU72819 136 VERIFICATION (SEQ 38) COMPLETE. SPA SPOOLER CLEAR IS COMPLETE ----------------------------- 16-0654 LPS NTD SPA SPOOLER CLEAR COMPLETE. NTD OTC SPA IS AVAILABLE FOR NORMAL 232 TBC RETRIEVAL OPERATIONS. PA PTC KSC CONVOY PREP --------------- 16-0655 -01H20M NCC LRD KSC CONVOY READY TO PROCEED WITH CCN LANDING/CONVOY OPERATIONS (S0028). 16-0656 LRD NCC RTLS RESCUE/MEDICAL OPERATIONS CCN READY TO SUPPORT LANDING. SECURITY CLEARED SLF OF ALL NONESSENTIAL PERSONNEL. 16-0657 NCC LRD VERIFY LANDING PERSONNEL WILL BE CCN ON SITE IN 30 MINUTES TO SUPPORT LRD ROC PRE-DEPLOYMENT BRIEFING. 135 EMS STM STM FSTM NET 104 828 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM G9 LAUNCH POLYNOMIAL/ TARGET UPDATE IF LAUNCH POLYNOMIAL UPDATE OR LAUNCH TARGET LOADS ARE REQUIRED. G9 LAUNCH POLYNOMIAL/TARGET UPDATE ---------------------------------- NOT PERFORMED ______ NOTE LAUNCH POLYNOMIAL UPDATES CAN BE PERFORMED ANY TIME PRIOR TO BFS ONE SHOT TRANSFER. 16-0658 -01H20M *FLT NTD LAUNCH POLYNOMIAL OR TARGET SU72831 UPDATE REQUIRED. 16-0659 NTD *FLT CONFIGURE FOR TWO STAGE COMMAND 232 MANUAL EXECUTE. 16-0660 *FLT NTD VERIFY READY TO RECEIVE UPLINK. NTD CVFS 232 16-0661 CVFS CURSOR CNTL (SAS10 PGB) FSW DISPLAY SELECT MENU (SDS13) XMIT CURSOR KEY - PRESS 16-0662 CVFS CURSOR CNTL (SAS10 PGB) UPLINK MONITOR (VWS14) XMIT CURSOR KEY - PRESS 16-0663 *FLT NTD STARTING ADDRESS FOR DOWNLIST CVFS DUMP: GMT L/O:__________ 829 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS IF LAUNCH POLYNOMIAL UPLINK IS REQUIRED. NOTED REQUIREMENT IS SATISFIED BY THE FOLLOWING STEPS. OMRS S00FF0.250-A 16-0664 NTD *FLT PERFORM AND VERIFY LAUNCH 232 POLYNOMIAL UPLINK. NOT PERFORMED ______ 16-0665 *FLT NTD LAUNCH POLYNOMIAL UPLINK COMPLETE. CVFS NOT PERFORMED ______ 16-0666 NOTED REQUIREMENT COMPLETE. OMRSD S00FF0.250-A NOT PERFORMED ______ NOTE PERFORM NEXT TWO STEPS IF LAUNCH DESIGNED TO ESTABLISH RENDEZVOUS CONDITIONS. 16-0667 NTD *FLT PROCEED WITH TRANSMISSION OF LAUNCH TARGET COMMANDS. NOT PERFORMED ______ 16-0668 *FLT NTD LAUNCH TARGET UPLINK COMPLETE. NOT PERFORMED ______ 16-0669 NTD *FLT RECONFIGURE FOR TWO STAGE COMMAND 232 AUTO COMPARE AND EXECUTE. 830 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE IF PERFORMING LAUNCH POLYNOMIAL UPDATE, NOTED REQUIREMENT IS SATISFIED BY COMPLETION OF FOLLOWING STEPS. OMRS S00FF0.250-B IF PERFORMING LAUNCH TARGETING UPDATE, NOTED REQUIREMENT IS SATISFIED BY COMPLETION OF FOLLOWING STEPS. JSC REQUEST NO. J3877 16-0670 NTD *FLT D/L DUMP TO BEGIN MOMENTARILY. 232 VERIFY READY TO RECEIVE DUMP DATA. 16-0671 CVFS NTD A MOMENTARY LOSS OF DOWNLIST 232 WILL OCCUR. VERIFY READY FOR NTD OTC DOWNLIST LOSS. TBC PTC LPS NOTE IF IMU ATT DET OR PREFLT ALIGNMENT IS IN PROGRESS, PERFORM NEXT STEP TO GET GNC CONCURRENCE PRIOR TO INITIATING GPC DOWNLIST DUMP. 16-0672 CVFS NTD VERIFY READY FOR GPC DOWNLIST 232 DUMP. DOWNLIST DATA WILL BE NTD OTC LOST FOR 2 TO 3 SECONDS. OTC CGNC 132 NOT PERFORMED ______ 16-0673 NTD CVFS PROCEED WITH GPC DOWNLIST DUMP. 232 831 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0674 CVFS CONSOLE KYBD VWS14 (UPLINK MONITOR) GUIDANCE POLYNOMIAL OR LAUNCH TARGETING XMIT CURSOR KEY - PRESS 16-0675 CVFS APPLICATION PAGE (VWS14 PGB) PFK 7 KEY - PRESS (DOWNLIST DUMP) 16-0676 CVFS FOLLOW PROGRAM PROMPTS START ADDRESS IS __________. 16-0677 CVFS NTD DOWNLIST DUMP COMPLETE. 16-0678 NTD *FLT VERIFY DOWNLIST DUMP DATA RECEIVED. NOTE PERFORM NEXT TWO STEPS AND REPERFORM PREVIOUS THREE STEPS IF ADDITIONAL DOWNLIST DUMPS ARE REQUIRED OR IF I-LOAD DATA NOT RECEIVED AND VERIFIED AT JSC. 16-0679 *FLT NTD READY TO RECEIVE DOWNLIST DUMP. NOT PERFORMED ______ 16-0680 CVFS PFP (VWS14) PFPK5 KEY - PRESS (DOWNLIST DUMP) NOT PERFORMED ______ 16-0681 *FLT NTD MCCH I-LOAD OR TARGET LOAD NTD CVFS VERIFICATION COMPLETE. | 232 | 832 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0682 PERFORM FOLLOWING: 1. IF A LAUNCH POLYNOMINAL UPLINK WAS PERFORMED, NOTED REQUIREMENT COMPLETE. OMRSD S00FF0.250-B NOT PERFORMED ______ SS1 2. IF A LAUNCH TARGET UPLINK WAS WAS PERFORMED, NOTED JSC REQUIREMENT COMPLETE. JSC REQUEST NO. J3877 NOT PERFORMED ______ SS2 16-0683 CVFS PFP (VWS14) PFPK2 - PRESS (RETURN) 16-0684 CVFS APPLICATION PAGE (VWS14 PGB) PFK15 KEY - PRESS (TERMINATE) 16-0685 CVFS APPLICATION PAGE (SAS10 PGB) SU72831 PFK 2 KEY - PRESS G9 LAUNCH POLYNOMIAL/TARGET UPDATE ---------------------------------- COMPLETE -------- 833 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0686 -01H20M NTD *SEC PERFORM FINAL CCF SWEEP AND SEC 232 STM SECURE ROADBLOCK A/B-10 AND PNU STM JSTC REPORT COMPLETION. SU72796 111 SU72832 JSTC GSPN 114 NOTE PERFORM NEXT THREE STEPS IF LEEWARD VENT DOORS 1 AND 2 NOT OPEN. 16-0687 OTC CPVD OPEN ORBITER VENT DOORS 1 AND 2 212 ON LEEWARD SIDE. NOT PERFORMED ______ 16-0688 CPVD CURSOR CNTL (VAM31A/VAM09A) VENT DOORS 1 AND 2 (LEEWARD) OPEN TARGET XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 16-0689 CPVD OTC LEEWARD VENT DOOR OPENING COMPLETE. NOT PERFORMED ______ HATCH CLOSURE ------------- 16-0690 -01H20M OTC OVCC CLOSE/LATCH INGRESS/EGRESS HATCH SU72789 212 FOR FLIGHT PER ORBITER OPERATION SUPPORT SETUP 20. (10 MIN) ER CMD CARRIER TEST ------------------- 16-0691 -01H20M NTD SRO PERFORM ER OPEN LOOP AUTOMATIC SU72833 232 COMMAND CARRIER CONTROL VALIDATION TESTS. 834 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ER HOLD FIRE CHECKS ------------------- NOTE | | PERFORM NEXT STEP AT | L-02H00M (STS-93). | | 16-0692 -01H10M NTD SRO PERFORM ER HOLD FIRE INDICATION SU72834 232 CHECKS PER A2811. REPORT COMPLETION. OMRSD P018JC.010 | | FINAL COLA UPDATE ----------------- 16-0693 -01H10M NTD SRO PROVIDE FINAL COLA UPDATE LAUNCH. SU72835 232 COLA 1 __________Z TO __________Z COLA 2 __________Z TO __________Z COLA 3 __________Z TO __________Z HATCH - CLOSED -------------- 16-0694 -01H10M OVCC OTC HATCH CLOSED AND LATCHED FOR SU72789 OTC CECL FLIGHT. (ORB OSSU 20) 212 CMQC 232 NTD NTD *PRL NET 105 16-0695 OTC CMQC VERIFY ORBITER OPERATION SUPPORT SU72791 212 SETUP 2, PART C, COMPLETE (ORB STRUCTURAL CONFIGURATION FOR LAUNCH). OMRS V00I00.030 835 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CABIN LEAK CHECK ---------------- 16-0696 -01H10M OTC CDR STANDBY TO PERFORM CABIN LEAK SU72790 212 CECL CHECK. MASTER ALARM AND LIGHT WILL COME ON AS A FUNCTION OF HIGH CABIN PRESSURE (CDR SHOULD NOTIFY CECL OF CABIN PRESSURE MASTER ALARM) CABIN KLAXON/ MASTER ALARM WILL ALSO SOUND DUE TO HIGH CABIN DECAY RATE (DURING CAP INSTALLATION) RESET MASTER ALARMS. 16-0697 OTC CDR PANEL L2A1 CABIN VENT VENT ISOL SW - OPEN UNTIL L2A1S3 VENT ISOL TB OP L2A1DS3 VENT TB CL L2A1DS4 16-0698 CECL CRT (VAG29 PG B) VERIFY CAB VENT - PCL ISOL - POP V61X2045E1 NOTE DURING ORB CABIN LEAK CHK, MASTER ALARM AND LIGHT WILL COME ON AS A FUNCTION OF HIGH CABIN PRESSURE (CDR SHOULD NOTIFY CECL OF CABIN PRESSURE MASTER ALARM) CABIN KLAXON/ MASTER ALARM WILL ALSO SOUND DUE TO HIGH CABIN DECAY RATE (DURING CAP INSTALLATION) RESET MASTER ALARMS. MASTER ALARMS MAY ALSO OCCUR IF EITHER PP02 SENSOR A OR B GOES ABOVE 3.6 PSIA. CECL WILL VERIFY CAUSE OF MASTER ALARMS. 16-0699 OTC CECL PERFORM CREW MODULE 212 OMTO PRESSURIZATION AND INITIAL CABIN 2 PSID LEAK CHECK PER S0007VL4 (SEQ 45 OPTION D) ON OIS CH 143. 836 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DURING ORB CABIN LEAK CHECK CABIN AIR SUPPLY PANEL C70-1226-2 AT 215 FT LVL WILL SHOW PRESSURE DROP FOR APPROXIMATELY 10 MIN. 16-0700 OTC NTD CREW MODULE O2N2 PNSA 232 PRESSURIZATION AND INITIAL NTD STM CABIN LEAK CHECK WILL BEGIN STM JBPN AT THIS TIME. 111 IMU GYROCOMPASS ALIGNMENT COMPLETE ---------------------------------- 16-0701 -01H05M CGNC OTC IMU GYROCOMPASS ALIGNMENT SU72827 212 COMPLETE. IMU'S IN ALIGNMENT OTC NTD MAINTENANCE MODE. 232 OMRSD V71AD0.050-1R GLS INITIALIZATION COMPLETE --------------------------- 16-0702 -01H00M CGLS OTC GLS INITIALIZATION COMPLETE. SU72821 212 16-0703 LPS C1MC PERFORM $FEPCPR, DEMAND UPDATE ON OIA, GPCA AND PLDA FEPS. TERM $FEPCPR AT COMPLETION OF DEMAND UPDATE. 16-0704 LPS C2MC VERIFY MNT TECH ON STATION TO SUPPORT PP1 AND PP2 THRU TERMINAL COUNT. 837 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0705 -01H00M NTD *SCC VERIFY EOD PERSONNEL ON SITE AT 232 A/B-11 ROADBLOCK. *SCC *PSE NET 105 16-0706 *PSE *SCC EOD PERSONNEL ON SITE AT NET A/B-11 ROADBLOCK. 105 *SCC NTD 232 16-0707 -01H00M STM PSTM SUPPORT PERSONNEL FOR POST JSTC 111 JSTC LAUNCH INSPECTION/SAFING WILL COMM GYCC ASSEMBLE AT COMPLEX J BY T-30 WSSA JSTC JFIR MIN. (30 MIN) JFIR 114 OIS SUPPORT CREW ---------------- 16-0708 GYCC JYCJ DISPATCH 2 OIS TECHS TO CX-J COMM 117 FOR POST LAUNCH SUPPORT. (ALL TECHNICIANS MUST HAVE CURRENT RED CREW CERTIFICATION.) HAZARDOUS FALLOUT ANNOUNCEMENT ------------------------------ 16-0709 GYCC GYCJ PROVIDE "HAZARDOUS FALLOUT" COMM 117 JYCJ ANNOUNCEMENT TO ALL AREAS ON "ALL AREA" PAGING SYSTEM. 16-0710 GYCJ GYCC "HAZARDOUS FALLOUT" ANNOUNCEMENT COMM JYCJ COMPLETE. 117 16-0711 -01H00M LSO LRD RTLS LANDING WILL BE ON LF1 RUNWAY ______. (15 OR 33) 838 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP AT DISCRETION OF LRD BASED ON PREDICTED RTLS RUNWAY. 16-0712 -01H00M LRD BRD DEPLOY SRB RECOVERY SHIPS TO 135 33 POSITION. NOT PERFORMED ______ 16-0713 -01H00M LRD *WEA REQUEST 8 HOUR WEATHER FORECAST 231 FOR SLF. TIME__________ PCT PRECIP__________ PCT LIGHTNING__________ WINDS__________ KTS DIR__________ NOTE PERFORM NEXT STEP IF WEATHER FORECAST INDICATES POTENTIAL RAIN EXPOSURE OR IF PREFERRED FOR NEXT FLOW PROCESSING. 16-0714 NCC LRD POSITION SSME'S IN RAIN DRAIN POST CCN LANDING. LRD LSO LF1 NOT PERFORMED ______ 16-0715 VCMP JCTL ALL VAB HIGHBAY AND TRANSFER CDPA JCTL STM AISLE DOORS CLOSED. 111 STM NTD 232 839 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0716 NCC LRD REPORT SURFACE WIND DIRECTION, CCN WIND VELOCITY AND DEW POINT. __________DEGREES __________KNOTS __________DEW POINT F NOTE ALL TIME CALLOUTS IN THIS OMI WILL BE IN MINUTES AND SECONDS FROM THIS POINT ON IN THE PROCEDURE. FLIGHT CREW FUNCTIONS WILL BE INITIATED BY CALL FROM OTC TO CREW. FLIGHT CREW WILL REPORT COMPLETION OF FUNCTION. S-BAND SYS HI PWR/FM ACTIVATION ------------------------------- NOTE OIS/GPCS/PLDS FEPS MAY GO NO GO DURING HI PWR/FM ACTIVATION. 16-0717 NTD OTC SUPPORT S-BAND TO HIGH POWER SU72801 232 ON CH 232. OTC CCSE 212 RCRT 16-0718 -55M00S NTD *FLT PERFORM S-BAND SYSTEM TO HIGH 232 *MIL POWER/FM ACTIVATION. 840 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0719 NTD *FLT TRANSMIT DSM 4724 (PREAMP V74K3073 232 2 ON). CCSE VWA40 VERIFY PREAMP-2 ON V74X4777E 16-0720 NTD *FLT TRANSMIT DSM 4756 (S-BAND V74K3065 232 PWR AMPL OPR-2 ON). CCSE VWA40 VERIFY V74X4785 PWR AMP-2 ON NOTE S-BAND PA 2 WILL NOT OUTPUT UNTIL STDN HIGH MODE IS COMMANDED. 16-0721 NTD *FLT TRANSMIT DSM 4734 (S-BAND V74K3102 232 MODE - STDN HIGH). CCSE VWA40 VERIFY: XPNDR MODE - STDN HI V74X4788E PWR AMP __________ WATTS V74E4513A (100W NOMINAL) 841 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0722 CCSE VWA40 VERIFY: FRAME SYNC LOCKED AGC __________(BD) SPE __________(BD) 16-0723 NTD *FLT TRANSMIT DSM 4780 (S-BAND V74K3145U FM SYSTEM-POWER 1 - ON). CCSE VWA40 VERIFY: V74X6120 OI XMTR-1 ON __________WATTS (RECORD) V74X4801E FM SP SRCE-ME DATA 16-0724 NTD *MIL VERIFY FM CARRIER + ME MODULATION 16-0725 NTD RCRT PERFORM FOLLOWING: 1. 8232 A4 (NB OI RCVR) CARRIER IND LITE ON 2. 8223 A6 (PATCH PNL) PATCH S-BAND FM OI VIDEO 1 (J237) TO WBTS LINE 2 (J19-C&T NO. 1 OR J26-C&T NO. 2) T:______ 842 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- S-BAND HIGH POWER/FM ACTIVATION - --------------------------------- COMPLETE -------- 16-0726 CCSE NTD S-BAND SYSTEM TO HIGH POWER/FM 232 ACTIVATION COMPLETE. FEP RF NTD *FLT SOURCE VERIFICATION CAN BE *MIL PERFORMED. RCRT OTC RF FEP SOURCE VERIFICATION -------------------------- 16-0727 NTD JRPS VERIFY RF MAIN ENGINE DATA, FROM SU72803 232 MILA, BEING RECORDED ON MAG TAPE RECORDER AND CONFIGURED TO FR FEED. VERIFY FRAME SYNC LOCK ON MAIN ENGINE 60 KBS DATA. NOTE DURING RF FEP SOURCE VERIFICATION, MAIN ENGINE, DATA WILL BE MOMENTARILY INVALID, WITH ASSOCIATED FEPS IN NO GO. ME MODULATION MUST HAVE BEEN APPLIED TO S-BAND FM SIG BY *FLT/CCSE BEFORE PROCEEDING WITH NEXT STEP. 16-0728 -55M00S NTD OTC PERFORM RF FEP SOURCE 232 LPS VERIFICATION ON CH 128 JRPS PER S0007VL4 (SEQ 70). OTC CCME REPORT COMPLETION. 212 16-0729 LPS JRPS CONFIGURE 505A1 (A7, A8, A9) BIT SYNCS TO SOURCE 2 MANUAL MODE, SOURCE 2, 60KB. 843 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0730 LPS AT LOCAL RCVS, CONFIGURE GPCS, OIS AND PLDS FEPS TO JSC OD DATA ON SOURCE 2 (6TVM4096/1TVM4097/6TVM4648) AND VERIFY GOOD LOCK. RETURN TO MILA DATA (6TVM1726/6TVM4649) UPON COMPLETION OF GOOD JSC OD DATA CHECKOUT. NOTE PERFORM NEXT THREE STEPS FOR VARIABLE WINDOW MISSIONS REQUIRING L-1H30M WINDOW UPDATE. 16-0731 *FLT NTD LAUNCH WINDOW INFORMATION UPDATE: 232 NTD CGLS WINDOW OPENS__________GMT SRO LRD PREFERRED LAUNCH__________GMT WINDOW CLOSE__________GMT LAUNCH T-0 AT PREFERRED LAUNCH TIME: PREFERRED PANE 1 CLOSE__________GMT PREFERRED PANE 2 OPEN__________GMT PREFERRED LOX DRAINBACK___MIN___SEC LAUNCH T-0 AT WINDOW OPEN TIME: WINDOW OPEN PANE 1 CLOSE__________GMT WINDOW OPEN PANE 2 OPEN__________GMT WINDOW OPEN LOX DRAINBACK___MIN___SEC NOT PERFORMED ______ 844 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0732 LRD SCO PREFERRED LAUNCH TIME IS__________GMT. 135 UPDATE PREFERRED RETRIEVAL SHIP COORDINATES. NOT PERFORMED ______ 16-0733 SCO LRD UPDATED PREFERRED RETRIEVAL SHIP 135 COORDINATES ARE AS FOLLOWS: RH SRB__________ LH SRB__________ NOT PERFORMED ______ 845 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACID DEPOSITION --------------- WEATHER BRIEFING ---------------- NOTE DO NOT PERFORM NEXT TWO STEPS IF WEATHER CONDITIONS HAVE NOT CHANGED SINCE LAST BRIEFING. 16-0734 -50M00S STM CBSE VERIFY READY FOR ACID DEPOSITION 163 WEATHER BRIEFING ON OIS CH 131. 221 *SCC NOT PERFORMED ______ 16-0735 -50M00S STM EEC PERFORM ACID DEPOSITION WX 131 BRIEFING. NOT PERFORMED ______ 16-0736 -50M00S SRO NTD ER SRSS VERIFICATION COMPLETE. 232 ER CARRIER OFF -------------- 16-0737 -50M00S SRO NTD ER COMPLETE WITH OPEN LOOP AUTOMATIC 232 COMMAND CARRIER CONTROL VALIDATION TEST, ER CARRIER OFF. 846 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- TERMINAL COUNT SRSS CLOSED -------------------------- LOOP TEST --------- NOTE | | ER CARRIER MUST BE OFF | PRIOR TO PERFORMING TERMINAL | COUNT CLOSED LOOP TEST. | | 16-0738 -50M00S TBC NTD REQUEST LPS AND FCA ON OIS SU72805 232 CH 175 TO SUPPORT CBRS. NTD LPS 16-0739 NTD SRO VERIFY READY TO SUPPORT 232 RSR TERMINAL COUNT CLOSED LOOP TEST. 16-0740 NTD TBC PERFORM TERMINAL COUNT SRSS 232 CLOSED LOOP TEST (SSRB4). TBC CBRS 136 16-0741 CBRS RSRT RANGE SAFETY REMOTE TECH SUPPORT 175 REQUIRED THRU SRB SEPARATION. RSRT WILL SUPPORT AS FOLLOWS AND REPORT ANY VIOLATION TO CBRS ON CH 175. 1. MONITOR RANGE SAFETY RF SIGNAL STRENGTH ON RACK 8234. SIGNAL SHOULD BE .2V +/- .1V DURING RANGE SAFETY TERMINAL COUNT CLOSED LOOP TEST. WHEN RANGE CARRIER APPLIED LEVEL SHOULD BE GREATER THAN 2.1V AND REMAIN CONSTANT TILL T-0. AFTER LIFTOFF SIGNAL LEVEL WILL VARY WITH VEHICLE TRACKING. 2. MONITOR RANGE SAFETY RACK 8234 TO ENSURE ARM AND FIRE LIGHTS OFF THRU SRB SEPARATION. 3. MONITOR RANGE SAFETY AUDIO AND REPORT ANY TYPE OF MODULATION. 847 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0741 4. VERIFY VCR'S AND STRIP CHARTS CON'T OPERATIONAL THRU SRB SEPARATION. 5. RACK 8234 PANEL A5 (STRIPCHART) - START T:______ 16-0742 CBRS FCA REQUEST SUPPORT THRU T-0 FOR MONITORING RANGE SAFETY CARRIER FREQUENCY. REPORT ANY ANOMALOUS SIGNALS OR MODULATION TO CBRS ON OIS CH 175. 16-0743 CBRS LPS PLACE P/P2, UNITS 1 AND 2 ON LINE 175 PER OMI S9002VL16. LPS C2MC 127 16-0744 CBRS LPS SPA SUPPORT REQUIRED FOR 175 RANGE SAFETY RETRIEVAL. LPS NTD 232 16-0745 CBRS TBC ATTENTION IN FR-___: 136 TBC NTD ALL CONSOLE OPERATORS ARE 232 REQUESTED TO REFRAIN FROM NTD CALLING UP SPA RETRIEVALS UNTIL PA RANGE SAFETY CHECKS ARE REPORTED COMPLETE. 16-0746 CBRS LPS REQUEST THREE TCB'S AVAILABLE 175 IN SPA TO SUPPORT TERMINAL LPS CPDR COUNT CLOSED LOOP TEST. 127 16-0747 CBRS CURSOR CNTL (SWRB2) ACTIVATE PRINTER/PLOTTERS - XMIT CURSOR KEY - PRESS 848 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0748 LPS CLDB PERFORM TAPE SWITCH AT LDBM IF 127 NORMAL TAPE SWITCH HAS NOT OCCURRED WITHIN LAST 5 MINUTES. NOT PERFORMED ______ 16-0749 LPS CLDB CONFIGURE LDBM SUBSYSTEM TO 127 RECORD IN DUAL ACCEPT MODE. REPORT COMPLETION. 16-0750 CBRS CRT (SWRB2) VERIFY MAJOR TEST PSEUDO S0007 16-0751 CBRS CURSOR CNTL (SWRB3) SSRB4 XMIT CURSOR KEY - PRESS SPA ON XMIT CURSOR KEY - PRESS 16-0752 CBRS CBP1 VERIFY RECEPTION OF ARM COMMANDS. (SHOULD BE 4 PULSES) 16-0753 CBRS CBP1 VERIFY RECEPTION OF FIRE COMMANDS. (SHOULD BE 4 PULSES) SRSS DATA RETRIEVAL ------------------- NOTE DO NOT PERFORM NEXT STEP IF ARM AND FIRE COMMANDS ARE VERIFIED ON PRINTER PLOTTERS. 16-0754 CBRS LPS PERFORM SRSS DATA RETRIEVAL ON 175 LDBM SYSTEM FOR TIME DURATION LPS CLDB PROVIDED BY CBRS. REPORT 127 COMPLETION. ARM START _____ FIRE STOP _____ NOT PERFORMED ______ 16-0755 LPS CLDB CONFIGURE LDBM TO RECORD IN DUAL 127 REJECT MODE. 849 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ER CARRIER ON ------------- CAUTION DO NOT BRING UP ER RANGE SAFETY CARRIER UNTIL REQUESTED BY CBRS. NOTE NEXT TWO STEPS ARE TO BE PERFORMED NO LATER THAN T-30M00S. 16-0756 -45M00S CBRS TBC REQUEST ER BRING UP RANGE SU72807 136 SAFETY CARRIER. TBC NTD 232 NTD SRO 16-0757 SRO NTD ER CARRIER SUPPORTING. 232 NTD TBC TBC CBRS 136 16-0758 CBRS CURSOR CNTL (SSRB4) RANGE CARRIER ON - XMIT CURSOR KEY - PRESS 16-0759 CBRS TBC TERMINAL COUNT CLOSED LOOP 136 RANGE SAFETY TEST COMPLETE. S&A DEVICES IN SAFE POSITION. OMRSD S00FH0.031-1 16-0760 TBC NTD SRSS CLOSED LOOP TEST COMPLETE. 232 S&A DEVICES IN SAFE POSITION. NTD *SCC 16-0761 CBRS LPS SPA SUPPORT FOR SRSS TEST 175 NO LONGER REQUIRED. LPS NTD 232 850 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0762 NTD ATTENTION IN FR___: PA SPA NOW AVAILABLE FOR NORMAL RETRIEVAL OPS. NOTE PERFORM NEXT EIGHT STEPS AFTER JSD OD DATA CHECKOUT COMPLETE. OIS, GPCS AND PLDS FEP TABLE RELOAD ----------------------------------- 16-0763 NTD LPS INHIBIT DATA PROCESSING ON OIS, 232 GPCS AND PLDS FEPS. RELOAD WITH $FEPCPR TABLES. REPORT COMPLETION. 16-0764 LPS C1MC I-RS OIA I-RS GPCA I-RS PLDA 16-0765 LPS C1MC I-DA OIS I-DA GPCS I-DA PLDS 16-0766 LPS C1MC $FLAI OIS, GPCS AND PLDS WITH CHECK POINTED TABLES. ($FLAI, XXXX, CKPT) 16-0767 LPS C1MC VIA AWP01, FORCE OIS, GPCS AND PLDS FEPS TO SOURCE 2, 192 KB DATA. 16-0768 LPS C1MC A-DA OIS A-DA GPCS A-DA PLDS 16-0769 LPS C1MC A-RS OIA A-RS GPCA A-RS PLDA 16-0770 LPS NTD DATA PROCESSING HAS RESUMED. OIS, 232 GPCS AND PLDS FEPS RELOADED WITH CHECK POINTED TABLES AND RETURNED TO RF SOURCE. 851 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0771 LPS JRPS DISCONNECT PAD HARD LINE DATA FROM MER CIRCUIT AND CONNECT 192 KB JSC OD DATA (SKR) (6TVM4096/97/6TVM4648). 16-0772 LPS JRPS VERIFY KMTS 0505A2 (A6) BIT SYNC INDICATING 192KB AND LOCKED ON | SIGNAL. | GLS MAINLINE ACTIVATION ----------------------- 16-0773 -45M00S OTC CGLS PERFORM GLS MAINLINE ACTIVATION. SU72809 212 REPORT WHEN COMPLETE. 16-0774 CGLS CONSOLE KYBD SELECT APP PG 3B - PRESS CRT MS/ML DISPLAY 16-0775 CGLS CURSOR CNTL INITIATE MAINLINE XMIT CURSOR KEY - PRESS 852 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF REQUIRED TO SELECT GLS PRESEQUENCER BYPASSES (AS APPLICABLE) FROM FOLLOWING LIST. 16-0776 CGLS SELECT APP PG 4B CRT SELECT GLS FUNCTIONS TO BYPASS CONSOLE KYBD (SGPO2) XMIT CURSOR KEY - PRESS FUNCTION BYPASS -------- ------ VENT DOOR 4/7 OVERRIDE ______ BRS LIMIT CHANGE ______ ONE SHOT DATA TRANSFER ______ T-20 MIN AUTO HOLD ______ OPS TRANSITION ______ SEND GMTLO ______ GPC DUMP AND COMPARE ______ SLPAO, SLPA1 PERFORMS ______ RF SWITCH SELECT ______ SINGLE SHOT VERIFY ______ T-9 MIN AUTO HOLD ______ BYPASS ALL ______ NOT PERFORMED ______ 853 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0777 CGLS CONSOLE KYBD (SGPO2) PFPK7 - PRESS PFPK4 - (SGPO2) - PRESS PFPK2 (PROCEED) - PRESS CRT (SPGO2) GLS MAINLINE ACTIVE MESSAGE 16-0778 CGLS PFPK7 - PRESS VERIFY - SGPO2 ACTIVE IN TASK 4 16-0779 CGLS OTC GLS MAINLINE ACTIVATION COMPLETE. 212 INITIAL CABIN LEAK CHECK COMPLETE --------------------------------- 16-0780 -45M00S CECL OTC CREW MODULE PRESSURIZATION AND SU72790 212 INITIAL CABIN INTEGRITY CHECK COMPLETE, PROCEED WITH CABIN VENT REDUNDANCY CONFIGURATION. 16-0781 OTC NTD CREW MODULE PRESSURIZATION PNSA 232 AND INITIAL CABIN INTEGRITY NTD STM CHECK COMPLETE. CABIN STM JBPN AIR SUPPLY PANEL C70-1226-2 111 (215 FT LVL) SHOULD SHOW NORMAL READINGS AT THIS TIME. 854 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CABIN VENT REDUNDANCY CONFIGURATION ----------------------------------- NOTE THE NEXT STEP MAY OCCUR EARLIER OR LATER AT CECL DIRECTION. 16-0782 -45M00S OTC CDR PERFORM CABIN VENT REDUNDANCY SU72792 212 CONFIGURATION. 16-0783 CDR PANEL L2A1 1. VENT ISOL SW - CLOSE L2A1S3 UNTIL VENT ISOL TB CL L2A1DS3 2. VENT SW - OPEN L2A1S4 UNTIL VENT TB OP L2A1DS4 16-0784 CDR OTC CABIN VENT REDUNDANCY CONFIGURATION CECL COMPLETE. DPS LCD SEQ ACTIVATION ---------------------- 16-0785 -45M00S OTC CDPS PERFORM DPS LAUNCH COUNTDOWN SU72811 212 SEQUENCE ACTIVATION. 16-0786 CDPS CURSOR CNTL (SAS01 PG B) DPS INIT DISPLAY (SAS01) XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS01 PG B) TERMINATE OPS MGR 5 (SAS25) XMIT CURSOR KEY - PRESS PFK2 KEY - PRESS 16-0787 CDPS CONSOLE KYBD VASJ6 PERF PGM KEY - PRESS 16-0788 CDPS CRT (VASJ6 PG B) VERIFY ALL FC AND PL BSR'S ARE ZERO. 855 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0789 CDPS APPL PAGE (VASJ6 PG B) PFK1 - PRESS (BSR READ CONTINUE) PFK1 - PRESS (NO NBAT UPDATE) CRT (VASJ6 PG B) VERIFY MSG "WAITING FOR GO FOR ONESHOT" 16-0790 CDPS OTC DPS LAUNCH COUNTDOWN SEQUENCE ACTIVATION COMPLETE. GLS PRE-SEQUENCING START ------------------------ 16-0791 -40M00S CGLS PFPK7 - PRESS VERIFY SGPR2 ACTIVE IN TASK 5 TRIAGE SITE DETERMINATION ------------------------- 16-0792 -40M00S NTD CBSE DETERMINE PREFERRED TRIAGE SITE 232 FOR REMAINDER OF LAUNCH PERIOD AND REPORT DETERMINATION. SITE LOCATION ---- -------- 2 A/B-5 ROADBLOCK 8 B-4 ROADBLOCK 3 PAD A PARKING LOT 4 PAD B PARKING LOT 9 NW OF PAD B 5 BEACH ROAD NORTH OF PAD B 6 BEACH ROAD SOUTH OF PAD A FINAL CABIN LEAK CHECK-COMPLETE ------------------------------- 16-0793 -40M00S CECL OTC CABIN VENT REDUNDANCY CHECK AND 212 FINAL CABIN INTEGRITY CHECK COMPLETE. 856 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CABIN VENT ---------- 16-0794 OTC CECL CRT PG B (VAG29) 212 RECORD DP/DT __________ PSI/MIN. (BD +/- 0.01) NOTE HIGH OXYGEN AND ARGON CONCENTRATION WILL BE RECORDED IN MIDBODY, PAYLOAD BAY, AND AFT ONCE CABIN IS VENTED. IT TAKES APPROXIMATELY 30 MINUTES FOR OXYGEN AND ARGON CONCENTRATIONS TO RETURN TO BASELINE VALUES PREVIOUS TO CABIN VENTING. DURING THIS TIME HGDS INTERPRETATION OF DATA FOR MEASURING TRENDS WILL BE USED TO VERIFY SYSTEM INTEGRITY. 16-0795 -40M00S CECL OTC READY FOR CABIN VENT, AIR WILL SU72793 212 BE VENTING INTO ORBITER PAYLOAD OTC CHGD BAY AND AFT. 232 NTD NOTE KLAXON AND M/A MAY OCCUR IN NEXT STEP DUE TO HIGH CABIN DECAY RATE. RESET MASTER ALARM. 16-0796 -40M00S OTC CDR OPEN CABIN VENT ISOL VALVE. 16-0797 CDR PANEL L2A1 VENT ISOL SW - OPEN UNTIL L2A1S3 VENT ISOL TB OP L2A1DS3 857 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0798 CECL CRT PAGE B (VAG29) CABIN VENT - POP ISOL - POP V61X2005E1 16-0799 CDR PANEL O1 VERIFY CABIN PRESS DECREASING 16-0800 CDR OTC CABIN VENT OPEN 16-0801 OTC CECL STANDBY TO GIVE PRO WORDS "CLOSE 212 CABIN VENTS" ON CH 212 IF DECREASE IN PPO2 BELOW BASELINE OBSERVED ON CRT PG-B (VAG29). NOTE PERFORM NEXT TWO STEPS IF CABIN VENT BEGAN AFTER L-35 MINUTES. 16-0802 OTC CHGD PROVIDE ESTIMATE FOR AFT O2 VALUE 212 TO BE LESS THAN 500 PPM. (5 MIN) NOT PERFORMED ______ 16-0803 CHGD OTC ESTIMATE AFT O2 VALUE WILL BE LESS 212 THAN 500 PPM IN ___ MINUTES. OTC NTD 232 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF ESTIMATE FOR AFT O2 PPM AT 500 PPM IS AFTER L-17 MINUTES. 16-0804 NTD OTC PERFORM SEQ 27, LATE CABIN VENT 232 CONTINGENCY. NOT PERFORMED ______ 858 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LAUNCH DIRECTOR/FLIGHT DIRECTOR ------------------------------- LAUNCH/RTLS WEATHER BRIEFING ---------------------------- 16-0805 -40M00S NTD STM REQUEST RANGE WX ON OIS CH 231 SU72738 232 TO SUPPORT WX BRIEFING. STM *WEA 231 16-0806 *FLT NTD LAUNCH DIRECTOR/FLIGHT DIRECTOR 232 LAUNCH/RTLS WEATHER BRIEFING COMPLETE. THERE (ARE/ARE NO) LAUNCH/RTLS WEATHER CONSTRAINTS. NOTE ANY DEVIATION FROM THE LIST OF PERSONNEL PROVIDED TO NTD AT T-4 HOURS MUST BE REPORTED ALONG WITH AN EXPLANATION FOR THE CHANGE. INCREASES TO APPROVED LDA ACCESS LIST MUST BE APPROVED BY NTD WITH SAFETY CONCURRENCE. 16-0807 NTD STM VERIFY NUMBER AND LOCATION OF COMM 232 SRO PERSONNEL WITHIN LDA THROUGH T-0 STM JSTC AS REPORTED AT T-4 HOURS. 111 GYCC JPHO GYCC WYVS PTP JSTC JFIR *SEC GSPN 859 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VENT DOOR 4 & 7 OVERRIDE OPERATION ---------------------------------- 16-0808 -38M00S CGLS CRT (SGPR2 PG B) VENT DOOR 4/7 OVERRIDE 16-0809 CGLS CRT (PG A) NOTE PERFORM ONE OF NEXT TWO SUBSTEPS. 1. FOR INITIAL LAUNCH ATTEMPT: VERIFY INITIAL VALUE OF V99J8836C1 - #0000 0000 NOT PERFORMED ______ SS1 2. FOR SUBSEQUENT LAUNCH ATTEMPTS: V99J8836C1 - #000F 0000 IF PREVIOUS ATTEMPT HAS BEEN MADE. NOT PERFORMED ______ SS2 3. VERIFY VALUE SENT TO SSV - #000F 0000 4. VERIFY VALUE FROM SSV - #000F 0000 OMRSD S00FA0.014 860 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WHITEROOM CLOSEOUT ------------------ 16-0810 -35M00S OTC OVCC CLOSEOUT WHITE ROOM PER ORBITER SU72795 212 OPERATION SUPPORT SETUP 20, VERIFY CHAMBER ECS AIR DAMPER OPEN AND ORBITER ECS AIR DAMPER CLOSED PASS/BFS TRANSFER PREP ---------------------- NOTE NOTED REQUIREMENT IS SATISFIED BY COMPLETION OF THE FOLLOWING FIVE STEPS. OMRS V72CA0.060-A 16-0811 -32M00S OTC CDR PERFORM PASS/BFS TRANSFER PREP. SU72813 212 16-0812 CDR PANEL C2 LEFT CRT SEL SW - 3 L KYBD RESUME CRT 3 GPC MEMORY 16-0813 CDR PANEL O6 GENERAL PURPOSE COMPUTER MODE 5 SW - STBY 5 TB RUN PANEL C3 BFC CRT DISPLAY SW - ON SELECT SW - 3+1 CRT 3 (BFS) BFS MEMORY 861 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0814 CDR L KYBD ITEM 25 EXEC CRT 3 25* CDR PANEL C2 L CRT SEL SW - 1 16-0815 CDR OTC PASS/BFS TRANSFER PREP COMPLETE. 212 16-0816 COMPLETION OF PREVIOUS FIVE STEPS SATISFIES NOTED OMRS REQUIREMENT. OMRSD V72CA0.060-A 16-0817 NTD *SEC REPORT WHEN ALL NONESSENTIAL SEC 232 PERSONNEL HAVE CLEARED LAUNCH DANGER AREA. 862 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP ONE HOUR PRIOR TO T-0 IF SRB RETRIEVAL SHIPS HAVE BEEN DEPLOYED AND ARE IN THE RETRIEVAL AREA. 16-0818 -30M00S BRD LRD OBSERVED RETRIEVAL AREA WEATHER 135 CONDITIONS ARE AS FOLLOWS: LRD *WEA (REFERENCE ONLY) 231 SS WINDS______ KNOTS PEAK WINDS______ KNOTS DIRECTION______ DEG SEA STATE __________ AIR TEMP______ DEG F BAROMETER______IN HG VISIBILITY______ MI OTHER WEATHER CONDITIONS____________ ____________________________________ ____________________________________ NOT PERFORMED ______ 16-0819 *WEA LRD FORECAST FOR TIME OF LAUNCH AT 231 SRB RETRIEVAL AREA: LRD NTD 232 PREDICTED WINDS:______ KNOTS NTD LD GUSTING TO:______ KNOTS WIND DIRECTION:______ DEG OMRSD S00L00.085 863 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OMS GN2 PRESS ------------- 16-0820 -30M00S OTC CDR PERFORM OMS GN2 PRESS. SU72772 212 16-0821 -30M00S CDR PANEL C3 OMS ENG LEFT SW - ARM/PRESS C3A01S001 RIGHT SW - ARM/PRESS C3A01S002 16-0822 CDR OTC OMS GN2 PRESS COMPLETE. 16-0823 COOS CRT (VWD72/VWD73) VERIFY LOMS ENG VLV ON ROMS ENG VLV ON LOME ARM/PR1 A/P LOME ARM/PR2 A/P ROME ARM/PR1 A/P ROME ARM/PR2 A/P LOME ARM VALVE (1AL) OPEN ROME ARM VALVE (1AR) OPEN PURGE VALVES (LP1,LP2) CLOSED PURGE VALVES (RP1,RP2) CLOSED LEFT OMS ENG REG OUT PRESS 330-375 PSIA V43P4549C1 RIGHT OMS ENG REG OUT PRESS 330-375 PSIA V43P5549C1 VERIFY NO UNEXPLAINED DOWNSTREAM PRESSURE CHANGE LOME BI-PROP VLV 1 POSN < 5% LOME BI-PROP VLV 2 POSN < 5% ROME BI-PROP VLV 1 POSN < 5% ROME BI-PROP VLV 2 POSN < 5% OMRSD V43CF0.120 (VWD72/VWD73) 864 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WSB GN2 SUPPLY ACTIVATION ------------------------- 16-0824 OTC PLT PERFORM WSB GN2 SUPPLY SU72774 212 ACTIVATION. 16-0825 PLT PANEL R2 APU/HYD BOILER N2 SUPPLY 1 SW - ON 2 SW - ON 3 SW - ON 16-0826 PLT OTC WSB GN2 SUPPLY ACTIVATION COMPLETE. 16-0827 CHYD CRT (VWF19) VERIFY WSB GN2 REG OUT PRESS 1-2-3: 39-44 PSIA CRT (VWF43) VERIFY N2 SUPPLY OFF 1-2-3: OFF OMRSD S00FJ0.015 GNC SCRS PRINTER/PLOTTER SETUP ------------------------------ 16-0828 -30M00S OTC COFC PLACE PP 2 UNITS 3 AND 4 ON 212 LPS LINE AND PERFORM SETUPS PER LPS C2MC OMI S9002VL16 (GNC SECTION). 127 PLACE OFF LINE WHEN COMPLETE. 16-0829 COFC APPL PG (SWB02 PG A) PFK 12 KEY - PRESS (ACTIVATE P/P SETUP) 16-0830 COFC CURSOR CNTL (SWB02 PG A) (ON ITEMS BELOW) XMIT CURSOR KEY - PRESS 1. A-MPS ENG POSN - SUB SYS = 2, ODV = 3 2. A-ELVN POSN, BF POSN, RUD POSN SUB SYS = 2, ODV = 4 865 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0831 COFC APPL PG (SWB02 PG A) PFK 12 KEY - PRESS (DE-ACTIVATE P/P SETUP) 16-0832 COFC OTC GNC SCRS PRINTER/PLOTTER SETUP COMPLETE. 212 ASSEMBLE POST LAUNCH -------------------- INSPECTION/SAFING TEAMS ----------------------- 16-0833 -30M00S NTD POST LAUNCH INSPECTION/SAFING CDPD PA TEAMS REPORT TO ASSEMBLY AREA SU72776 AT COMPLEX J. 16-0834 -30M00S OTC *PAD NOTIFY POST LAUNCH INSPECTION/ 212 SAFING PERSONNEL TO ASSEMBLE AT COMPLEX J. 16-0835 -30M00S PSTM STM ALL SUPPORT PERSONNEL REQUIRED JSTC JSTC FOR POST LAUNCH SAFING/INSPECTION STSA | 111 ASSEMBLED AT COMPLEX J. 16-0836 -30M00S STM VEEE DELIVER FSS ELEVATOR LOCK AND CDPD NET COVER TO PAD SAFETY AT COMPLEX J. 104 (5 MIN) T:______ MEC PRE-FLIGHT BITE ------------------- 16-0837 -29M00S OTC CEPD CHECK MEC PRE-FLT BITE. 212 16-0838 CEPD CURSOR CNTL (MEC/PIC AUTO TEST MENU) LAUNCH PREFLT BITE XMIT CURSOR KEY - PRESS 16-0839 CEPD PFP (VSC24) CONTINUE - PRESS CRT (VSC24) PORT 1 SUCCESSFUL PORT 3 SUCCESSFUL 866 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0840 CEPD CRT (VSC24) PREFLIGHT BITE MEC-1 AND MEC-2 (MEC ONLY) IF WORD 4 BITS 13 AND 17 = 0, VERIFY WORD 2 BITS 9,11-18,23,24 = 0 AND WORD 4 BIT 18-22 = 0 IF WORD 5 BITS 13 AND 17 = 0, VERIFY WORD 3 BITS 9,11-18,23,24 = 0 AND WORD 5 BIT 18-22 = 0 IF WORD 4 AND 5 BITS 13 AND 17 = 1 A CRITICAL CMD HAS BEEN ISSUED TO THE MEC THEN WORD 2 BIT 9 AND BITS 11-24 = DONT CARE AND WORD 3 BIT 9 AND BITS 11-24 = DONT CARE AND WORD 4 BIT 13 AND 18-22 = DONT CARE AND WORD 5 BIT 13 AND 18-22 = DONT CARE NOTE MAKE HARDCOPY BEFORE NEXT TERMINATING STEP CLEARS SCREEN. 16-0841 CEPD PFP (VSC24) TERMINATE - PRESS NOTE MASS SPEC AUTO CALS WILL ALWAYS START AT L-49M00S FOR LONG AND SHORT LAUNCH WINDOWS. FOR SHORT LAUNCH WINDOWS, AUTO CALS WILL START AT THE BEGINNING OF THE T-9M00S HOLD. HGDS, BUHGDS AND HUMS AUTO CALS ------------------------------- 16-0842 -29M00S CHGD PERFORM HGDS, BUHGDS AND HUMS SU72852 L-49M00S JHGD AUTO CALS AND CONFIDENCE CHECKS. 867 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GLS LIMIT CHANGE COMPLETE ------------------------- 16-0843 -26M00S CGLS OTC GLS LIMIT CHANGE AND DUAL 212 NOTIFICATION FOR BRS COMPLETE (AUTO). 16-0844 NTD *SEC SECURE ROADBLOCKS A/B-4, A-5, SEC 232 A-3, A-6 (FOR PAD A LAUNCH) OR B-3, B-4 (FOR PAD B LAUNCH) AND GO HARDDOWN ON A/B-11 AND A/B-15. 16-0845 -25M00S *SEC NTD NONESSENTIAL PERSONNEL CLEAR OF SEC 232 LDA AND CCF. SU72832 NTD *SCC 868 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SIMO A/G VOICE CHECK & ASCENT CREW ---------------------------------- DATA UPDATE ----------- 16-0846 -25M00S OTC CDR STANDBY TO PERFORM SIMO A/G 212 VOICE CHECK. 16-0847 -25M00S NTD *FLT PERFORM SIMO VOICE CHECKS AND 232 ASCENT CREW DATA UPDATE. 16-0848 *FLT ALL SIMO A/G VOICE CHECKS AND ASCENT CREW DATA UPDATE COMPLETE. 16-0849 *FLT CDR READING OUT RTLS AND TAL ALT PLT SETTING AND RUNWAY. PASS - BFS TRANSFER (DEU EQUIV.) -------------------------------- 16-0850 -22M00S CGLS CRT (PG 5A) ONESHOT DATA XFER COMM SENT TO DPS 16-0851 CDPS CRT (VASJ6 PG-B) VERIFY ONE-SHOT COMPLETE MILESTONE IN INVERT GREEN VERIFY MSG: WAITING FOR GO TO TRANSITION OMRSD V72CA0.060-B 16-0852 CGLS CRT VERIFY ONESHOT XFER COMPLETE ANNOUNCE T-20 MINUTE HOLD ------------------------- 16-0853 -22M00S NTD THE CDC WILL HOLD AT T-20 MIN. PA 212 232 869 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RECORD CABIN PRESS ------------------ 16-0854 -22M00S CECL OTC CABIN VENT COMPLETE. READY FOR 212 CABIN PRESS READING. 16-0855 OTC CDR PANEL O1A1 REPORT CABIN PRESS __________ PSIA BD 01A1M4 16-0856 CECL CRT (VAG29 PAGE B) RECORD CABIN PRESS __________15.2 PSIA MAX V61P2405A1 OMRS V61AQ0.010-1 (VAG29) 16-0857 OTC CDR CRT 3 212 ESTABLISH BFS SM SYSTEM SUMMARY 1 DISPLAY. REPORT CABIN PRESSURE __________PSIA BD CDR PANEL C2 | LEFT CRT SELECT SW - 3 CRT 3 MAJ FUNCT SW - SM CDR LEFT KYBD (BFS) | SYS SUMM CRT 3 BFS SM SYS SUMM 1 870 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0858 OTC CDR CRT 3 212 RESTORE GNC BFS OPS DISPLAY. (BFS MEMORY DISPLAY IF PRE-OPS 1, BFS LAUNCH TRAJ1 DISPLAY IF POST OPS 1) CDR LEFT KYBD (BFS) | RESUME CDR PANEL C2 | CRT3 MAJ FUNC SW - GNC LEFT CRT SELECT SW - 1 CDR CRT 3 | BFS MEMORY (IF OPS 0) LAUNCH TRAJ (IF OPS 1) CLOSE VENT VALVES ----------------- NOTE VENT VALVE CLOSING MAY OCCUR EARLIER OR LATER AT CECL DIRECTION. 16-0859 OTC CDR CLOSE CABIN VENT VALVES. SU72794 212 16-0860 CDR PANEL L2A1 CABIN VENT VENT ISOL SW - CLOSE UNTIL L2A1S3 VENT ISOL TB CL L2A1DS3 VENT SW - CLOSE UNTIL L2A1S4 VENT TB CL L2A1DS4 16-0861 CECL CRT (VAG29 PAGE A) VERIFY CAB VT AND CAB VT ISOL DISCRETES ARE DISPLAYED CLOSED 16-0862 CDR OTC VENT VALVES CLOSED. 212 871 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLEAR CLOSEOUT CREW FROM PAD ---------------------------- 16-0863 -20M00S OVCC OTC WHITE ROOM SECURED PER ORBITER SU72778 212 OPERATION SUPPORT SETUP 20. ALL SU72795 OTC NTD PERSONNEL CLEARING BACK TO ROAD 232 BLOCK. FLIGHT CREW RESCUE NTD *SCC LOCKER EQUIPMENT REPLACED AND *PAC LOCKER SECURED (LATCHED AND PINNED). SLIDEWIRE BASKETS IN POSITION. ALL CLOSEOUT CREW TOOLS ACCOUNTED FOR. 16-0864 -20M00S NTD OTC PERFORM CLEARING OF CLOSEOUT SU72784 232 CREW FROM FSS. OTC OVCC 212 1. POSITION FSS ELEVATORS AT PAD SURFACE LEVEL. 2. REMOVE ELEVATOR ELSA'S 3. DEPRESS BOTH RED BUTTONS ON PANEL BETWEEN ELEVATORS. 4. VERIFY ALL ELEVATOR DOORS OPEN. 16-0865 -20M00S NTD JFIR CLOSEOUT CREW DEPARTING PAD. FIRE 232 HT__ AFTER VERIFING SLIDEWIRE SU72780 JFIR *HT3 BASKET DECELERATION NETS IN SU72782 NET *ENG PLACE YOU ARE CLEARED TO LEAVE PAD AND RETURN TO A/B-4 (PAD B) A-5 (PAD A). ENG A/B-4 (PAD B), ENG A-5 (PADA) PROCEED WITH CLOSEOUT CREW TO ROADBLOCK A/B-11. 16-0866 -20M00S NTD STM PROVIDE VIDEO TRACKING AND COMM 232 RECORDING OF 3 BUNKER CREW PERSONNEL STM JYVO TO ROADBLOCK A/B-4 (PAD B) A-5 138 JYVR (PAB A) AND CLOSEOUT CREW PAD TO ROADBLOCK A/B-11. (SEE JYVO FIG 4) 872 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONFIG ORBITER VENT DOORS 1 AND ------------------------------- 2 TO NORMAL PURGE POSITION -------------------------- 16-0867 -20M00S OTC CPVD ENVIRONMENTAL CHAMBER CLEARED 212 OF PERSONNEL, RECONFIGURE VENT DOORS 1&2 TO PURGE POSITION. (5 MIN) 16-0868 CPVD CURSOR CNTL (VAM09A) VENT DR 1&2 PURGE TARGET- XMIT CURSOR KEY - PRESS CRT (VAM09A) VERIFY ALL VENT DOORS ARE IN NORMAL PURGE CONFIGURATION AND V99J8836C1 IS 000F0000. 16-0869 CPVD OTC ALL VENT DOORS IN NORMAL PURGE 212 CONFIGURATION. OTC NTD 232 873 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ***T-20 MINUTE HOLD*** ---------------------- 16-0870 -20M00S NTD THE CDC IS HOLDING AT T-20 MIN. (HOLDING) PA 232 212 136 16-0871 CGLS CONSOLE KYBD (SAP28 PG B) PFK15 - PRESS TERM PG TERM CONC XMIT CURSOR KEY - PRESS VERIFY SAP28 INACTIVE 16-0872 NTD SPE REPORT HOLD TIME CONSTRAINTS. 232 ______MIN ______SEC 16-0873 NTD CLOX REPORT GO2 ULLAGE PRESSURE 232 GENERIC CERTIFICATION HOLD TIME. _____MIN ______SEC 16-0874 NTD *FLT REPORT LOX DRAINBACK PERFORMANCE 232 HOLD TIME. ______MIN ______SEC NOTE PERFORM NEXT STEP IF REQUIRED BY *FLT. 16-0875 NTD *FLT PROCEED WITH TRANSMISSION OF 232 REMAINING ASCENT VARIABLE PARAMETERS. NOT PERFORMED ______ 874 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GLS SOFTWARE REQUIREMENTS ------------------------- NOTE THE FOLLOWING OMRS REQUIREMENTS WILL BE AUTOMATICALLY PERFORMED BY GLS SOFTWARE IN THE LAST 20 MINUTES OF LAUNCH COUNTDOWN. ALL LISTED REQUIREMENTS WILL BE MET BY T-ZERO. (REF KLO-82- 0071 APPX A). GLS EVENTS ARE NOT ANNUNCIATED DURING FINAL COUNT UNLESS SPECIFIED IN OMI. GLS S/W MAY BE MASKED AS REQUIRED TO SUPPORT LAUNCH. DETAILS OF GLS MASKS AND BYPASSES ARE SPECIFIED AS DATA SHEETS IN SEQ 62 S0007VL4. 16-0876 CGLS VERIFY GLS S/W CONFIGURED TO PERFORM OMRS FUNCTIONS REFERENCED BELOW. MINUS TIME NOMENCLATURE OMRS ---------- ------------ ---- -09M00S & CNTG INITIATE TERM COUNT S00FM0.020-1 -05M00S ARM SRB S & A DEVICES S00FM0.210-1R -04M30S SSME MFV HTRS OFF S00FM0.040 -04M00S SSME PURGE SEQ 4 S00FM0.250-1 875 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MINUS TIME NOMENCLATURE OMRS ---------- ------------ ---- -03M55S AEROSURFACE PROFILE S00FM0.270-1 -03M30S MPS GIMBAL PROFILE CK S00FM0.300-1R -03M20S VFY BODY FLAP DISCRETES S00FM0.290-1R -03M03S VFY SSMES IN START POSN S00FM0.310-1 -03M03S VFY BODY FLAP POSNS S00FM0.280-1 -02M55S TERM SSME GN2 PURGE S00FM0.350-1 -02M50S TERM GOX VENT HOOD PURGE S00FM0.360 -02M50S RETRACT GOX VENT HOOD S00FM0.370-1 -00M55S LOCK SRB MDM LL1/LR1 S00FN0.040-1R -00M50S GSE POWER REMOVAL S00FN0.840 -00M50S DEACT SRB JOINT HTRS S00FN0.825 -00M48S CLOSE LH2/LO2 OTBD S00FP0.050-1 FILL VLVS -00M40S GSE POWER RMVL VERIF S00FP0.060-1 -00M40S ET BIPOD HTRS OFF S00FP0.030-1 -00M31S RSLS AUTO SEQ START S00FR0.010 -00M30S SRB HPU GAS GEN BED HEATERS S00FF0.170 -00M28S START SRB HPU'S S00FR0.070-1 -00M21S SRB GIMBAL TEST S00FS0.030-1 -00M16S VFY HDP, TSM & ET VAS ORDNANCE ARMED S00FS0.080-1R -00M16S ACTIVATE SS WATER S00FT0.120 -00M16S VFY SPEEDBRAKE LAUNCH POSN S00FM0.280-1 -00M13S LOCKOUT AFT SRB MDMS S00FS0.090-1R -00M12S TERM MPS HE FILL S00FT0.040-1 -00M10S ACTIVATE H2 BURN PYROS S00FT0.110 -00M10S REMOVE SRSS INHIBITS S00FT0.020-1R -00M10S PWR DOWN MDMS LA1/LF1/LM1 V72CA0.070 -00M10S ISSUE GO FOR SSME START S00FT0.100 -00M08S DEACTIVATE MPS LH2 RECIRC SYS & CLOSE RECIRC VALVES S00FT0.050-1 -00M08S SHUTDOWN GCU'S S00FS0.020 876 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OMRSD S00FF0.170 (SGPW2) OMRSD S00FM0.020-1 (SLP07) OMRSD S00FM0.210-1 (SGPT2) OMRSD S00FM0.040 (SGPT2) OMRSD S00FM0.250-1 (SGPT2) OMRSD S00FM0.270-1 (SSPS1) OMRSD S00FM0.300-1R (SSPS1) OMRSD S00FM0.310-1 (SGPU2) OMRSD S00FM0.280-1 (SGPU2) OMRSD S00FM0.290-1R (SGPU2) OMRSD S00FM0.350-1 (SGPU2) OMRSD S00FM0.360 (SLPJ0) OMRSD S00FM0.370-1 (SLPJ0) OMRSD S00FN0.040-1R (SGPW2) OMRSD S00FN0.825 (SGPW2) OMRSD S00FN0.840-1 (SGPW2) OMRSD S00FP0.050-1 (SGPW2) OMRSD S00FP0.060-1 (SGPW2) OMRSD S00FP0.030-1 (SGPW2) OMRSD S00FR0.010 (SGPW2) OMRSD S00FR0.070-1 (SGPW2) OMRSD S00FS0.030-1 (SSPS1) OMRSD S00FS0.080-1R (SLP26) OMRSD S00FS0.090-1R (SLP26) OMRSD S00FT0.040-1 (SLP26) OMRSD S00FT0.020-1R (SLP26) OMRSD S00FT0.120 (SLP26) OMRSD S00FT0.110 (SLP26) OMRSD V72CA0.070 (SLP26) OMRSD S00FT0.100 (SLP26) OMRSD S00FT0.050-1 (SLP26) OMRSD S00FS0.020 (SLP26) 877 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SET CDC START TIME ------------------ 16-0877 -20M00S CGLS NTD CDC TO START AT:____/__ (HOLDING) 232 HHMM SS 16-0878 NCC LRD CONVOY PREPARING TO MOVE TO CCN DEPLOYMENT LOCATION. 16-0879 OTC JRPS VERIFY MTU TEST SET IS DELAY 0 212 AND LOCK ON LAUNCH VEHICLE. MTU MONITOR KYBD F3 - PRESS (NEXT MTU) UNTIL LAUNCH VEHICLE IS HIGHLIGHTED F2 - PRESS VERIFY LOCKED ON LAUNCH VEHICLE RECORD IN CHANGE LOG CONSOLE PROGRAM ASSIGNMENTS --------------------------- 16-0880 -20M00S NTD OTC VERIFY FR CONSOLE SOFTWARE SU72843 (HOLDING) 232 TBC CONFIGURED PROPERLY FOR PTC T-20 MIN. ONLY PROGRAMS LPS LISTED MAY BE ACTIVE. ORBITER PROGRAMS ---------------- 16-0881 OTC ALL ALL ORBITER SYSTEMS VERIFY PROGRAM 212 SOFTWARE. REPORT ONLY IF ANY DISCREPANCIES. 16-0882 CSME VERIFY PROGRAM VAE38A ACTIVE IN C3 16-0883 CMPL VERIFY PROGRAM SAE02 ACTIVE IN C3 16-0884 CMPS VERIFY PROGRAMS VAE18 ACTIVE IN C4 SAE12 ACTIVE II C4 16-0885 CCSE VERIFY PROGRAMS VWA40 ACTIVE IN C2 878 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0886 CNSE VERIFY PROGRAMS VAA40 ACTIVE IN C2 VAA41 ACTIVE IN C2 16-0887 CPLE VERIFY PC GOAL PROGRAM OVERVIEW 2 ACTIVE AT C5 16-0888 CPVD VERIFY PROGRAMS VAM01A ACTIVE IN C6 VAM31A ACTIVE IN C6 16-0889 CECL VERIFY PROGRAMS VAG34 ACTIVE IN C5 VAG28 ACTIVE IN C5 VAG29 ACTIVE IN C5 16-0890 CFCP VERIFY PROGRAMS VWR05 ACTIVE IN C6 VWR70 ACTIVE IN C6 VWR04 ACTIVE IN C6 VWR06 ACTIVE IN C6 (EDO MISSIONS ONLY) 16-0891 CGSS VERIFY PROGRAMS VAJ02 ACTIVE IN C7 VAJ14 ACTIVE IN C7 16-0892 CAFM VERIFY PROGRAM VAK20 ACTIVE IN C5 VAK21 ACTIVE IN C5 16-0893 COOS VERIFY PROGRAMS VADL7 ACTIVE IN C7 VADL8 ACTIVE IN C7 VADL9 ACTIVE IN C7 VADL0 ACTIVE IN C7 16-0894 CHYD VERIFY PROGRAMS VWF19 ACTIVE IN C8 VWF43 ACTIVE IN C8 16-0895 CAPU VERIFY PROGRAMS VWF48 ACTIVE IN C8 VWF57 ACTIVE IN C8 879 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0896 CISL VERIFY PROGRAMS SAQ04 ACTIVE IN C9 VAQ29 ACTIVE IN C9 16-0897 CHGD VERIFY PROGRAMS SAW01/HWW50 ACTIVE IN C9 16-0898 CEPD VERIFY PROGRAMS SWC02 ACTIVE IN C10 VWC17 ACTIVE IN C10 VWC10 ACTIVE IN C10 16-0899 COFC VERIFY PROGRAMS SAB19 ACTIVE IN C11 SAB20 ACTIVE IN C11 SAB21 ACTIVE IN C11 VABM1 ACTIVE IN C11 16-0900 CDPS VERIFY PROGRAMS SAS01 ACTIVE IN C12 VASP9 ACTIVE IN C12 VAS59 ACTIVE IN C12 VASJ6 ACTIVE IN C12 VASB9 ACTIVE IN C12 16-0901 CCME VERIFY PROGRAM VWE01A ACTIVE IN C12 NOTE TERM ALL OC TASKS AND GLS LOOKUPS AT INTG BEFORE CDC IS RESUMED. VERIFY ONE OF FOLLOWING TWO GROUPS OF PROGRAMS BASED ON EDO/SPACEHAB MISSION REQUIREMENTS. 16-0902 CGLS VERIFY PROGRAMS SLP03 ACTIVE IN INTG SLP02 ACTIVE IN INTG SLP01 ACTIVE IN INTG SGPO2 ACTIVE IN INTG SGPR2 ACTIVE IN INTG NOT PERFORMED ______ 880 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0903 CGLS VERIFY PROGRAMS SLP81 ACTIVE IN INTG SLP02 ACTIVE IN INTG SLP01 ACTIVE IN INTG SGPO2 ACTIVE IN INTG SGPR2 ACTIVE IN INTG NOT PERFORMED ______ 16-0904 CTPE VERIFY 2 AVAILABLE CONCURRENCE IN B/U VERIFY PROGRAMS SLPBO ACTIVE IN B/U SLPCO ACTIVE IN B/U SEP03 ACTIVE IN B/U SEP03 ACTIVE IN B/U LPS PROGRAMS ------------ 16-0905 LPS VERIFY PROGRAMS ACTIVE IN MSTR: $HWM0N (TCB1) AA008/AWP02 (TCB2) AA009/AWP01 (TCB4) SLP50 (TCB5) SA001 (TCB6) SRB/ET PROGRAMS --------------- 16-0906 TBC ALL ALL SRB/ET SYSTEMS VERIFY PROGRAM SOFTWARE. REPORT ONLY IF ANY DISCREPANCIES. 16-0907 -20M00S CLOX VERIFY FOLLOWING: (HOLDING) 1. PROGRAMS GAL01 ACTIVE IN C3 GAL02 ACTIVE IN C3 2. SSL03 ACTIVE IN LOX REPLENISH CONTROL LOOP READY TO RECEIVE GLS INTERRUPTS. 881 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0908 CLHY VERIFY FOLLOWING: 1. PROGRAMS GAH01 ACTIVE IN C4 GAH02 ACTIVE IN C4 GAW02 ACTIVE IN C4 2. SSH03 ACTIVE (LH2 S/W CONFIGURE TO ACCEPT GLS INTERRUPT) 16-0909 -20M00S CBRS VERIFY PROGRAMS (HOLDING) SARB4 ACTIVE IN C2 SWRB2 ACTIVE IN C2 16-0910 CBHY VERIFY PROGRAM BAT04 ACTIVE IN C8 16-0911 CPWR VERIFY PROGRAM BWE08 ACTIVE IN C10 BWE11 ACTIVE IN C10 16-0912 TBC CMEC VERIFY READY TO PICK UP AT T-20 MIN. 16-0913 CLOX TBC JCFM NO LONGER REQUIRED ON OIS 136 CH 158 FOR LOX PUMP INSTRUMENTATION TBC NTD RECORDING. SUPPORT RELEASED. 232 NTD STM STM JCFM 111 882 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAYLOAD PROGRAMS ---------------- NOTE PERFORM ONE OF THE NEXT THREE | SUBSTEPS IF PAYLOAD CONSOLE | PROGRAMS ARE ACTIVE. 16-0914 -20M00S PTC CLES VERIFY C-1 CONSOLE PROGRAMS ACTIVE (HOLDING) GLES DLES 1. FOR SPACEHAB (POWERED) RS0002 RW0017 PAH001 PAH001A PAH002 PAHLCCD NOT PERFORMED ______ SS1 2. FOR OTHER PAYLOADS RW0017 RA0003 RS0002 EA0013 NOT PERFORMED ______ SS2 | 3. FOR IUS | | RW0017 | UW0002 | UW0003 | UW0004 | RA0003 | UW0005 | PW0004 | NOT PERFORMED ______| SS3 | 883 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0915 PTC NTD FR C1 CONSOLE SOFTWARE CONFIGURED. 232 16-0916 -20M00S CDPS VERIFY TWO CONSECUTIVE OC (HOLDING) TASK CONCURRENCIES AVAILABLE TO PERFORM GPC DUMP. EXTEND HOLD TIME (CONTINGENCY) ------------------------------ NOTE PERFORM NEXT THREE STEPS IF HOLD MUST BE EXTENDED. 16-0917 NTD CGLS CANCEL PENDING. 232 NOT PERFORMED ______ 16-0918 NTD HOLD WILL BE EXTENDED. PA 232 NOT PERFORMED ______ 16-0919 CGLS SELECT APP PG 3B CURSOR CNTL SELECT - CANCEL PENDING CDC REQUESTS - PRESS NOT PERFORMED ______ 16-0920 STM JCTL VERIFY PRINTER PLOTTERS 1, 2 111 AND 3 ON LINE. 884 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- REQUEST SILENCE ON NET 105 -------------------------- 16-0921 -20M00S NTD *SCC REQUEST SILENCE BE MAINTAINED (HOLDING) 232 ON RADIO NET 105 FROM -5 MINUTES UNTIL +4 MIN 23 SEC. LRD WILL NOTIFY *SCC AT THAT TIME IF NET 105 REQUIRED FOR RTLS. DECOMS ON RF SOURCE ------------------- 16-0922 NTD JRPS VERIFY DECOMS ON RF SOURCE. SU72845 T-20 MINUTE RECYCLE ENTRY POINT ------------------------------- NOTE COUNTDOWN WILL RESUME AT THIS POINT IF A T-20 MINUTE RECYCLE OCCURS. 16-0923 -20M00S NTD ALL TEST TEAM PERSONNEL SWITCH SU72847 (HOLDING) 232 TO CH 212 ACTIVE THRU T-0. ALL 136 PERSONNEL NOT ACTIVE IN TEST PA SWITCH TO CH 217. (MONITOR ONLY CH 212) 16-0924 -20M00S NTD FCO COMMUNICATIONS VERIFICATION (HOLDING) 212 CHECK OIS CH 212. 16-0925 NTD CHGD VERIFY ACTIVE CH 212 AND MONITOR WSSA 212 CGSS CH 232 FOR REMAINDER OF COUNT. SU72849 JBFX JHGD | 885 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT FOUR STEPS IF PAYLOAD SIGNAL PROCESSOR (PSP) IS POWERED UP. POWERING DOWN PSP IS REQUIRED TO BE PERFORMED IN GNC9. 16-0926 OTC CDR PSP WILL BE POWERED DOWN. ALERT 212 CDPS WILL OCCUR. NOT PERFORMED ______ 16-0927 NTD OTC SUPPORT PSP DEACTIVATION ON CH 232. 232 *FLT PTC OTC CCSE 212 NOT PERFORMED ______ 16-0928 NTD *FLT TRANSMIT DSM 4801 (P/L SYSTEM OFF) 232 CCSE VAA06 VERIFY PSP OFF PL INTER OFF NOT PERFORMED ______ 16-0929 CCSE NTD PSP DEACTIVATION COMPLETE. 232 NTD *FLT NOT PERFORMED ______ 886 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LRD FINAL STATUS CHECKS ----------------------- NOTE SOME LANDING SITES MAY NOT BE MANNED DUE TO MISSION REQUIREMENTS. 16-0930 -20M00S LRD LSO READY FOR LANDING SITE VERIFICATION. (HOLDING) LF1 ALL LANDING SITES VERIFY GO FOR LAUNCH. SITE GO NO/GO N/P ---- -- ----- --- BANJUL ______ ______ ______ BEN GUERIR ______ ______ ______ ZARAGOZA ______ ______ ______ MORON ______ ______ ______ WSSH ______ ______ ______ DFRF ______ ______ ______ 16-0931 LRD STM VERIFY SUPPORT SYSTEMS AT KSC COMM 135 SHUTTLE LANDING FACILITY READY STM GYCC FOR LAUNCH. 111 GYCC FMLS 117 16-0932 EMS LRD PRELAUNCH TRIAGE SITE IS 135 HELIPAD__________. LRD ROC 135 887 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE LANDING SITES AND LANDING AIDS STATUS TO BE UPDATED ONCE EVERY 24 HOURS DURING THE MISSION. WEATHER CONDITIONS LANDING CONSTRAINTS AND RUNWAY STATUS. CONVOY AND GSE STATUS VERIFY LANDING SITES PRE-OPERATIONS ARE ON SCHEDULE TO SUPPORT LIFT-OFF TIME. 16-0933 LRD BRD VERIFY BOOSTER RETRIEVAL FORCES 135 ON STATION AND READY FOR LAUNCH AND GIVE STATUS OF SRB IMPACT AREA. 16-0934 LRD SCO BOOSTER RETRIEVAL FORCES READY 135 FOR LAUNCH AND SRB IMPACT AREA CLEAR (OR NOT CLEAR) OF NONESSENTIAL VESSELS. NOTE PERFORM NEXT STEP AT THE T-20 MINUTE HOLD IF SRB RETRIEVAL SHIPS HAVE BEEN DEPLOYED AND ARE IN THE RETRIEVAL AREA OR THERE IS NO CHANGE IN WEATHER. 16-0935 *WEA LRD FORECAST FOR TIME OF LAUNCH AT 231 SRB RETRIEVAL AREA: LRD NTD 232 PREDICTED WINDS:______ KNOTS NTD LD GUSTING TO:______ KNOTS WIND DIRECTION:______ DEG OMRSD S00L00.085 NOT PERFORMED ______ 888 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0936 -20M00S NTD CONDUCT BRIEFING ON OIS CH 212 SU72851 (HOLDING) AND 232. T-20 MIN BRIEFING ----------------- (TO BE PERFORMED 5 MIN PRIOR TO END OF HOLD OR AS REQUIRED FOR SHORT WINDOW MISSIONS) 16-0937 NTD PERFORM FOLLOWING: 212 232 1. THE LAUNCH WINDOW OPENS AT ______ GMT CLOSES AT ______ GMT THE PERIOD OF LAUNCH OPPORTUNITY: BEGINS AT ______ GMT ENDS ______ GMT THE TARGET LAUNCH TIME WILL BE FINALIZED DURING T-9M HOLD. A SECOND LAUNCH ATTEMPT IS/IS NOT POSSIBLE IF A RECYCLE OCCURS 2. THERE ARE/ARE NO COLLISON AVOIDANCE (COLA) TIMEFRAMES WITHIN THE LAUNCH WINDOW. COLA 1 START _____ GMT END _____ GMT COLA 2 START _____ GMT END _____ GMT 889 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0937 3. IF LAUNCH CANNOT BE CON'T ACCOMPLISHED WITHIN THE LAUNCH WINDOW (OR IF THE FOLLOWING TIME IS EXCEEDED) CUTOFF WILL BE CALLED. CONSTRAINT HOLD TIME ---------- --------- LOX DRAINBACK HOLD TIME OF __________ AND IS BASED ON ENGINE (PERFORMANCE/ STARTBOX) CONSTRAINT START TIME HOLD TIME ---------- ---------- --------- LOX DRAINBACK T-4M55S _________ 4. PLT - AT T-5 MINUTES PERFORM APU START UPON COMMAND OF OTC ONLY. 5. CDR - THE PAD EGRESS SYSTEM IS/IS NOT IN NOMINAL CONFIGURATION THE EVACUATION HELIPAD IS ____. 6. CONTROL ROOM LAUNCH TEAM - DISABLE TELEPHONE RINGERS AT THIS TIME. 7. CONTROL ROOM ACCESS WILL BE RESTRICTED AFTER RESUMING THE COUNT AT T-20 MIN, UNTIL AFTER LAUNCH OR FLIGHT CREW EGRESS. 8. ALL PERSONNEL NOT ACTIVE IN TERMINAL COUNT WILL MONITOR OIS CHANNEL 217. 890 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0937 9. AFTER T-20 MINUTES, ALL PROBLEMS CON'T OR TRENDS THAT REQUIRE A CDC HOLD WILL BE REPORTED TO THE NTD ON CHANNEL 212 TOGETHER WITH RECOMMENDATION. AFTER T-5 MIN., ANY HOLD, MANUAL OR GLS, SHOULD BE ACCOMPANIED BY A DESCRIPTION OF THE PROBLEM AND A RECOMMENDATION. THE COUNTDOWN CLOCK WILL CONTINUE UNTIL T-31 SEC UNLESS THE RECOMMENDATION TO HOLD AT THE NEXT MILESTONE IS NECESSARY. 10. AT T-9 MINUTES WHEN A "GO" IS GIVEN, IT INDICATES THAT THE REPORTING ELEMENT IS FREE OF PROBLEMS WHICH COULD PREVENT A SUCCESSFUL LAUNCH. IF A HOLD COMMAND IS REQUESTED AND ISSUED BETWEEN T-9 MINUTES AND T-31 SECONDS, THE COUNTDOWN CLOCK WILL BE RESTARTED UPON SUCCESSFUL RESOLUTION OF THE PROBLEM WITHOUT A "GO" SURVEY MADE OF ALL ELEMENTS. AFTER T-31 SECONDS, ONLY CUTOFF IS AVAILABLE AND WILL RESULT IN A RECYCLE TO T-20 MINUTES. FOR A CUTOFF, PROWORDS "CGLS GIVE CUTOFF" WILL BE USED. 11. FOR IUS MISSIONS: | | IF CLOCK HOLDS AT T-5M00S, ICC1 | TAKES ACTION ONLY UPON DIRECTION | OF THE NTD. | | A. IF HOLD IS 30 SEC DURATION | OR LESS, NO ACTION REQUIRED. | | B. IF HOLD IS GREATER THAN | 30 SEC, THE NTD WILL DIRECT | ICC1 TO ISSUE A REFRESH. | THIS DIRECTION WILL BE GIVEN | WHEN ANTICIPATED RETURN TO | COUNT IS WITHIN 4M00S. UPON | SUCCESSFUL UPLINK OF REFRESH, | ICC1 SHALL REPORT "REFRESH | COMPLETE AND IUS GO" | | 891 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0937 C. IF COMMAND FOR ISSUE OF | CON'T REFRESH IS GIVEN AND COUNTDOWN | DOES NOT RESUME WITHIN 4 MIN, | THE NTD WILL DIRECT AN | ADDITIONAL REFRESH WHEN | COUNTDOWN IS ANTICIPATED | TO RESUME WITHIN 4M00S. | | IF HOLDS OCCUR AFTER T-5 MINS. | AND COUNTING, IUS WILL NOT BE | CONSIDERED IN RESUMING THE | COUNT. | | 12. THE GLS MILESTONES ARE: | T-9M00S GLS SEQ START T-7M30S OAA RETRACT T-5M00S APU START T-4M00S PURGE SEQ 4 T-2M55S LOX PRESSURIZATION T-1M57S LH2 TERM REPLENISH T-31S LPS GO FOR GPC AUTO SEQ 13. SPE - ANY COMMENTS FOR CREW. | T-20 MIN BRIEFING COMPLETE -------------------------- 892 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE NEXT SIX STEPS MAY BE PERFORMED ANYTIME DURING T-20 MIN HOLD AND ARE INDEPENDENT OPERATIONS WHERE THE RM SBTC CHECK (LDB READS) MUST BE COMPLETE PRIOR TO OPS 101 TRANSITION. RETURN DEU 2 TO C12 ------------------- 16-0938 CGNC CURSOR CNTL (VABM1/VSB90 PG B) DEU RETURN XMIT CURSOR KEY - PRESS DEU 2 XMIT CURSOR KEY - PRESS C CO _DEU2G LDBA C12 XMIT CMD KEY - PRESS 16-0939 CGNC OTC RESPONSIBLE CONSOLE FOR DEU2 212 CDPS NOW C12. ACTIVATE PROFILE MONITOR ------------------------ 16-0940 COFC CURSOR CONTROL (SAB19/SWB01) COUNTDOWN - DETAIL EXEC CMD KEY - PRESS 16-0941 COFC APPL PG B (SAB21/VWB05) PFK1 KEY - PRESS (START) 893 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RH SBTC CHECK - LDB READ ------------------------ NOTE THE NEXT TWO STEPS SATISFY LCC GNC-04. 16-0942 COFC PFP (SAB20/SWB02) PFPK2 - PRESS (SBTC BITE TEST 4) 16-0943 COFC CRT (SAB20/SWB02 PG B) RH SBTC STATUS SUCCESSFUL 16-0944 -20M00S NTD ATTENTION ALL PERSONNEL, THE (HOLDING) PA CDC WILL RESUME AT _____ GMT. 212 16-0945 CGLS VERIFY 2 CONCURRENCIES AVAILABLE IN BACKUP CONSOLE FOR MAINLINE INTERRUPT ACTIVATION. 16-0946 OTC CGSS START SECOND HCU PUMP PER OMI V2160. TAPE SWITCH PDR SUB-SYS ----------------------- 16-0947 -20M00S LPS CPDR PERFORM TAPE SWITCH AT PDR (HOLDING) 127 SUBSYSTEM IF A NORMAL TAPE SWITCH HAS NOT OCCURRED WITHIN PREVIOUS 5 MINUTES. NOT PERFORMED ______ 894 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0948 CMQC SUPPORT: 1. FUEL CELL PRELAUNCH CONDITIONING (OIS CH 151 AT T-13M) 2. RECORDER ACTIVATION (SEQ 38) (OIS CH 145 AT T-9M HOLD) 3. APU PRE-START AND POST-START CHECKS (SEQ 42) (OIS CH 182 AT T-6M15S) RESUME COUNT ------------ NOTE CGLS WILL MONITOR LPS AND GPC COUNTDOWN TIME. IF A DELTA OF GREATER THAN 2 SEC DEVELOPS, CGLS WILL NOTIFY NTD AND CDPS. 16-0949 -20M00S CGLS CDC WILL START ON MY MARK (HOLDING) 212 3-2-1 MARK 16-0950 -20M00S NTD T-20 MINUTES AND COUNTING SU72855 (COUNTING) PA __________ GMT 895 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ACTIVATE VHF WX CIRCUIT ----------------------- NOTE FLIGHT CREW WEATHER BRIEFING WILL BE PATCHED INTO ICOM-B ONLY AT REQUEST OF *FLT. 16-0951 -20M00S *FLT NTD PERFORM FOLLOWING: COUNTING 212 NTD STM 1. WEATHER BRIEFING REQUESTED COMM STM GYCC BY *FLT. SU72859 111 GYCC GOIS YES_____ NO_____ 117 GYCJ 2. ACTIVATE 2RAC534 (VHF WEATHER 126.65 MHZ RADIO CIRCUIT) TO ICOM-B FOR FLIGHT CREW WEATHER BRIEFING. VERIFY COMPLETION. NOT PERFORMED ______ SS2 896 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- -20M00S OPS TRANSITION COUNTING -------------- NOTE ELEVONS WILL MOVE TO LAUNCH POSITION AFTER OPS 101 TRANSITION. IF BODY FLAP POSITION IS NOT WITHIN +/- 1.5 DEGREES OF COMMANDED POSITION (0 DEGREES) UPON ENTRY TO OPS 101, A BODY FLAP FAIL INDICATION WILL BE DISPLAYED TO CREW. UPON HYDRAULIC PRESSURIZATION BODY FLAP WILL BE AUTOMATICALLY DRIVEN BY FLIGHT SOFTWARE BACK WITHIN +/- 0.7 DEGREES OF COMMANDED POSITION AND FAIL INDICATION WILL BE AUTOMATICALLY RESET. 16-0952 -20M00S CDPS CRT (VASJ6) COUNTING (VERIFY MESSAGES AS THEY APPEAR:) "OPS TRANSITION IN PROGRESS" "PASS IN 101, ACTIVE DOWNLIST FMT 21" "TAKE BFS TO OPS 101" 16-0953 CDPS OTC PASS OPS TRANSITION COMPLETE. SU72861 212 DPS READY FOR BFS TRANSITION TO OPS 101. OMRSD S00FK0.025-A-1R BFS TO OPS 1 ------------ 16-0954 -18M30S OTC CDR CLEAR PASS FAULT SUMM (SPEC 99 SU72863 212 PRO) AND TAKE BFS TO OPS 1 PER YOUR CHECKLIST. 16-0955 CDR PANEL O6 GPC MODE SW - RUN GPC MODE 5 TB RUN 897 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0956 CDR OTC BFS OPS 1 TRANSITION COMPLETE. 212 16-0957 -18M00S CGLS VERIFY SLPAO AND SLPA1 ACTIVE IN BACKUP CONSOLE. 16-0958 CGLS VERIFY DOWNLISTED GMTLO TBO IS +/- 2 SEC OF PLANNED LIFTOFF TIME. OMRSD S00E00.960-1 T-20 MIN GPC DUMP ----------------- NOTE DUMP WILL REQUIRE APPROX 10 MINUTES. 16-0959 CDPS CRT (VASJ6 PG B) SU72865 T-20 MINUTE DUMP IN PROGRESS FLIGHT CONTROLS READY VERIFICATION ---------------------------------- 16-0960 -17M00S COFC CRT (VWB05 PG B) SU72867 ELEVON, RUD & SPBK DRVR CURRENTS ARE GO MPS TVC DRVR CURRENTS ARE GO SRB TVC DRVR CURRENTS ARE GO OMRS V79GEN.100 898 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ALTERNATE TAL SITE SELECTION ---------------------------- (CONTINGENCY) ------------- NOTE PERFORM NEXT STEP IF ALTERNATE TAL SITE SELECTION REQUIRED. 16-0961 *FLT PLT PERFORM ALTERNATE TAL SITE SU72869 SELECTION FOR TAL SITE_____ (1-5) DURING HORIZ SIT CONFIG. NOT PERFORMED ______ HORIZ SIT CONFIG ---------------- 16-0962 -17M00S OTC PLT CONFIGURE PASS AND BFS SU72871 212 HORIZONTAL SITUATION DISPLAYS PER YOUR CHECKLIST. 16-0963 PLT OTC HORIZONTAL SITUATION CONFIGURATION COMPLETE. CONTINGENCY ABORT YAW STEER (PASS) ---------------------------------- 16-0964 OTC CDR CONFIG CONTINGENCY ABORT YAW SU72873 212 STEER PER YOUR CHECKLIST. 16-0965 CDR OTC CONTINGENCY ABORT YAW STEER CONFIGURATION COMPLETE. READY FOR BFS UPLINK -------------------- 16-0966 -16M00S CVFS CRT (VASB9, PAGE B) BFS TRACKING PASS FC STRG 1-4 CYAN NSP STAT GOOD OMRSD S00FK0.030-1R 16-0967 CVFS NTD READY FOR BFS UPLINK. 232 899 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- BFS PRE-FLT U/L LOADING ----------------------- NOTE BFS LOAD'S WILL UPDATE TMBU'S, TDRS STATE VECTOR AND LAUNCH TARGET LOADS AS REQUIRED. 16-0968 -16M00S NTD *FLT PERFORM BFS PREFLIGHT UPLINK SU72875 LOADING. 16-0969 *FLT NTD BFS PREFLIGHT UPLINK LOAD CVFS COMPLETE. VERIFY WSB QTY -------------- 16-0970 CHYD CRT (VWF19) SU72877 VERIFY WSB 1-2-3 BACKUP QTY (BFS DERIVED) 82-88 PCT FOR 118 POUND WATER LOAD 95-100 PCT FOR 140 POUND WATER LOAD WSB NO. 1 V98Q1970C1/V72Q6040V1 WSB NO. 2 V98Q1971C1/V72Q6042V1 WSB NO. 3 V98Q1972C1/V72Q6044V1 MPS HE RECONFIGURATION ---------------------- 16-0971 OTC PLT PERFORM MPS HE RECONFIGURATION. SU72879 212 16-0972 PLT PANEL R2 MPS HE ISOLATION A LEFT SW - OPEN CTR SW - OPEN RIGHT SW - OPEN HE ISOLATION B LEFT SW - OPEN CTR SW - OPEN RIGHT SW - OPEN HE ISOL SW - OPEN 900 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0973 PLT OTC MPS HE RECONFIG COMPLETE. 16-0974 -15M00S CMPS CRT (VAE18 PGB) VERIFY FOLLOWING OPEN POWERS ARE ON, SWITCH SCANS INDICATE OPEN: ENG 1,2,3 REG ISOL A&B MPS REG ISOL 1 AND 2 OMRSD S00FK0.080-1 16-0975 -15M00S CMPS CRT (SAE12) VERIFY "ORB VLV PWRS OK" DISPLAYED OMRSD S00FK0.050-B-1R 16-0976 -15M00S CMPL CRT (SAE02) VERIFY "ORB VLV PWR ON CHECKS OK" DISPLAYED OMRSD S00FK0.050-A-1R 16-0977 JSTC *SEC SECURITY ROVING BEACH PATROL - SEC 114 RESPOND TO ASSIGNED BUNKER AREAS AT THIS TIME. CONFIGURE OMS/RCS CROSSFEED VALVES ---------------------------------- FOR FLIGHT ---------- NOTE PERFORM OMS/RCS XFEED VALVE CONFIGURATION PER CDC. 16-0978 -15M00S OTC COOS CONFIGURE OMS/RCS CROSSFEED SU72881 212 FOR FLIGHT. 901 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT TWO STEPS IF ALL CROSSFEEDS ARE CLOSED. 16-0979 COOS CURSOR CNTL (VWD42) C4 - CLOSE CRT VERIFY OMS XFD VALVE CLOSED NOT PERFORMED ______ 16-0980 COOS CURSOR CNTL (VWD41) C4 - CLOSE CRT VERIFY OMS XFD VALVE CLOSED NOT PERFORMED ______ 16-0981 COOS VWD73 SWITCH SCAN VERIFY SWITCH POSITIONS FOR LAUNCH 16-0982 COOS VADL7 VERIFY VALVES CONFIGURED FOR FLIGHT 16-0983 COOS OTC OMS/RCS CROSSFEED VALVES CONFIGURED 212 FOR FLIGHT. OMRSD V42BF0.130 OMRSD V43CF0.130 SRB AFT SKIRT GN2 PURGE HIGH FLOW --------------------------------- ACTIVATION ---------- 16-0984 -15M00S TBC CBHY INITIATE SRB AFT SKIRT GN2 HIGH SU72883 136 FLOW RATE PURGE FOR BOTH LEFT AND RIGHT SRB'S. 902 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT STEP IF SRB AFT SKIRT GN2 PURGE ALREADY FLOWING AT A MINIMUM OF 90 PSI FLOWING PRESSURE. 16-0985 CBHY CURSOR CNTL (BAT04) SRB AFT SKIRT GN2 PURGE DC PWR PRI - ON SEC - ON CURSOR CNTL (BAT04) SRB AFT SKIRT GN2 PURGE (VALVING) (MAIN) PRI-OP SEC-OP CRT SRB AFT SKIRT GN2 PURGE (TEMPERATURE/PRESSURE) PRG ON CURSOR CNTL (BAT04) SRB AFT SKIRT GN2 PURGE (HEATER) (ARROWS) ADJUST SET POINT TO 70 +/- 5 CURSOR CNTL (BAT04) SRB AFT SKIRT GN2 PURGE (HEATER) CMD - ON CURSOR CNTL (BAT04) SRB AFT SKIRT GN2 PURGE (HEATER) (ARROWS) ADJUST SET POINT TO 95 +/- 5 NOT PERFORMED ______ 903 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE EITHER PRESSURE MEASUREMENT (PRIMARY OR ALTERNATE) MAY SATISFY SPECIFICATION. 16-0986 CBHY CRT (BAT04) SRB AFT SKIRT GN2 PURGE (TEMPERATURE/PRESSURE) PSI 90 (MINIMUM) OMRSD S00FM0.430-1 16-0987 CBHY TBC SRB AFT SKIRT GN2 HIGH FLOW 136 ACTIVATION COMPLETE. SRB AFT SKIRT GN2 PURGE HIGH FLOW --------------------------------- ACTIVATION COMPLETE ------------------- CONFIG BAT04 FOR LCD -------------------- 16-0988 -15M00S CBHY CONFIGURE BAT04 FOR LAUNCH COUNTDOWN. 16-0989 CBHY CURSOR CNTL (BAT04) C/D MDE (BLOCK) XMIT CURSOR UNTIL - LNH LAUNCH AREA CLEAR VERIF (-15M) ------------------------------ 16-0990 *PSE *SCC CLOSEOUT CREW AT ROADBLOCK SU72784 NET A/B-11. 105 *SCC NTD 212 *PAC 16-0991 *SCC NTD ALL NONESSENTIAL PERSONNEL HAVE CLEARED LAUNCH DANGER AREA EXCEPT THOSE PERSONNEL LOCATED BY SPECIFIC LIST AT FORWARD OBSERVER SITES. 904 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-0992 -15M00S NTD STM TERMINATE VIDEO TRACKING OF COMM | 212 CLOSEOUT CREW AND DEACTIVATE SU72887 | STM JYVO PAD OIS-D. | 138 JYVR STM GYCC | 111 | GYCC JYCD | 117 | 16-0993 -15M00S NTD SRO KSC AREA CLEAR FOR LAUNCH. SU72885 212 16-0994 -13M00S JRPS START BMU STRIP CHART RECORDERS. (OMI S9002VL16) FUEL CELL PRELAUNCH CONDITIONING -------------------------------- NOTE ECL MONITOR HEAT LOAD IMPACT IN NEXT STEP. FCP CONDITIONING LOADS MUST BE APPLIED FOR 10 MINUTES MINIMUM IMMEDIATELY PRECEDING APU START. 16-0995 OTC CEPD ADJUST FUEL CELL LOADS TO SU72889 CFCP BETWEEN 250 AND 290 AMPS. 905 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE INDIVIDUAL FUEL CELL CURRENTS ARE ALLOWED TO BE LESS THAN 250 AMPS EACH, ASSUMING THE TOTAL VEHICLE POWER IS NOT LESS THAN 23 KW. STEADY STATE OPERATION OUTSIDE SPECIFIED TEMPERATURE LIMITS MAY BE ACCEPTABLE PROVIDED FCP INLET AND OUTLET KOH CONCENTRATIONS REMAIN WITHIN 24-48 PCT. ANY VIOLATION OF SPECIFIED TEMPERATURE LIMITS REQUIRES DESIGN ENGINEERING ASSESSMENT. 16-0996 CFCP MONITOR FUEL CELL PERFORMANCE USING FOLLOWING CRITERIA: VOLTAGE 28.325 VOLTS MIN (REF FIG V45CH0.010-1) CURRENT 250-290 AMPS TOTAL FC POWER 23 KW MIN STACK COOL OUT TEMP REF FIG V45CH0.010-2 COND EXIT TEMP 140-160 DEG F COOLANT RET TEMP 40-140 DEG F COOLANT PRESSURE 65 +/- 10 PSIA STACK COOL IN TEMP 176-191 DEG F OMRSD V45CH0.050 906 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ANNOUNCE HOLD TIME ------------------ 16-0997 -12M00S NTD CDC WILL HOLD AT T-9 MINUTES. 212 PA NOTE | | FOLLOWING STEP IS TIME | CRITICAL AND MUST BE | INITIATED PRIOR TO | L-22 MIN. | | OEX RECORDER ACTIVATION ----------------------- (PRE-LAUNCH CONFIG) (OV-102 ONLY) --------------------------------- NOTE PERFORM NEXT TWO STEPS IF REQUIRED BY *FLT (OV-102 ONLY). 16-0998 NTD *FLT ACTIVATE OEX RECORDER FOR SU72891 CISL PRE-LAUNCH SEQUENCE. JRPS (SEQ 38 S0007VL4). NOT PERFORMED ______ 16-0999 CISL NTD PRE-LAUNCH MADS AND OEX RECORDER CONFIGURATION COMPLETE. NOT PERFORMED ______ PENDING SET VERIFICATION ------------------------ NOTE FOLLOWING PENDING SET IS PERFORMED BY GLS, BY THE CLOCK. 16-1000 -12M00S LPS AWP01 PG-B VERIFY SOURCE 2 HI RATE, VOICE YES PENDING IN GPCA, OIA, AND SOURCE 2 IS PENDING IN ME1, ME2, ME3 FEPS 907 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1001 LPS SET SOURCE 2 HIGH RATE VOICE YES (192 KB) PENDING IN PLDA FEP. VERIFY CONTINGENCY SUPPORT OPS ------------------------------ READY FOR LAUNCH ---------------- 16-1002 -12M00S LRD *DCD VERIFY CONTINGENCY SUPPORT SU72893 135 ROC OPERATIONS READY FOR LAUNCH. EMS EMERGENCY AIRCRAFT AND PERSONNEL ON STATION. 16-1003 LRD NCC CONTINGENCY SUPPORT ON STATION. SU72899 CCN READY FOR RTLS. LRD LSO LFP1 BSR READ -------- 16-1004 -10M00S CCME READ EIU BSR'S VWE01 PFP READ EIU GPC BSR - PRESS NOTE PERFORM NEXT STEP IF BU OR MSTR CONSOLE AND VWE01 IS NOT LOADED. 16-1005 CCME READ EIU BSR'S CBTU RBSR EIUX XMIT CMD EXEC CMD (X = 1,2,3 FOR EIU 1,2,3) NOT PERFORMED ______ 16-1006 -10M00S STM JBAC MONITOR MLP CHWR LINE PRESSURE HVAA 111 DURING AND JUST AFTER LIFTOFF. SU72895 908 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1007 -10M00S JYCD GYCC OIS-D DEACTIVATED TO PAD. COMM 117 SU72887 GYCC STM 111 STM NTD 212 16-1008 OTC ALL DISCONTINUE ALL NON-MANDATORY LDB 212 TRAFFIC FOR REMAINDER OF COUNT. SINGLE SHOT VERIFY ------------------ 16-1009 -09M30S CGLS (SELECT APPL PG 6B) SU72897 CRT VERIFY SINGLE SHOT FAILURES DISPLAY NOTE PERFORM NEXT TWO STEPS IF ERRORS OCCUR. 16-1010 CGLS APPL PAGE 6B HARD COPY KEY - PRESS PFK15 KEY - PRESS REPEAT PREVIOUS STEP UNTIL MSG 'VERIFY CYCLE COMPLETE' APPEARS ON PG-6B NOT PERFORMED ______ 16-1011 CGLS PFP TERM VFY'S - PRESS CRT VERIFY INTEGRATED MENU NOT PERFORMED ______ 909 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ***T-9 MINUTE HOLD*** --------------------- 16-1012 -09M00S NTD T-9 MINUTES AND HOLDING (HOLDING) PA 212 T-20 MIN GPC DUMP - COMPLETE ---------------------------- 16-1013 -09M00S CVFS NTD T-20 MIN GPC DUMP COMPLETE. SU72865 (HOLDING) 212 NTD OTC OMRSD S00FK0.025-B-1R NOTE PERFORM NEXT STEP IF EXPECTED MISCOMPARES OCCUR. 16-1014 CDPS CONSOLE KYBD (VASJ6 PG B) PFK 3 KEY - PRESS NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF UNEXPECTED MISCOMPARES OCCUR. 16-1015 CDPS CONSOLE KYBD (VASJ6 PG B) PFK-2 KEY - PRESS NOT PERFORMED ______ 16-1016 CDPS CURSOR CNTL (SAS01 PG-B) DPS INIT DISPLAY XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS01 PG-B) ACTIVATE OPS MGR 5 (SAS25) XMIT CURSOR KEY - PRESS PFK2 KEY - PRESS 910 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM FINAL LAUNCH WINDOW DETERMINATION AT L-39M FOR RENDEZVOUS MISSION WITH SHORT DURATION WINDOW. FINAL LAUNCH WINDOW DETERMINATION --------------------------------- NOT PERFORMED ______ 16-1017 -09M00S NTD *FLT READY FOR WINDOW DETERMINATION SU72901 (HOLDING) 212 DISCUSSION WITH LD ON OIS 231. 16-1018 -09M00S LD NTD LAUNCH TIME OPENING WILL BE (HOLDING) 231 *FLT __________ (WINDOW OPEN OR PREFERRED LAUNCH TIME) 16-1019 NTD *FLT PROVIDE UPDATE TO LOX DRAINBACK 212 HOLD TIME AND LAUNCH/RTLS WEATHER CONSTRAINTS. LOX DRAINBACK HOLD TIME (PERFORMANCE) _____ MIN _____ SEC 16-1020 -09M00S NTD OTC FINAL LAUNCH WINDOW OPENING WILL BE (HOLDING) 212 TBC L-37M00S PTC __________GMT (WINDOW OPEN OR LPS PREFERRED LAUNCH TIME) AND WILL *MIL STM CLOSE AT __________GMT. THERE *SCC (IS/IS NOT) A LAUNCH WINDOW CUTOUT: SPE LRD CUTOUT BEGINS:__________GMT SRO CDR CUTOUT ENDS:__________GMT DURING THE CUTOUT PERIOD, LAUNCH WILL NOT BE ATTEMPTED. LOX DRAINBACK HOLD TIME IS___M___S AND BASED ON ENGINE (STARTBOX/ PERFORMANCE/GO2 CERTIFICATION.) NOT PERFORMED ______ 911 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1021 NTD CGLS SET CDC TO RESUME AT ___:___/___ | 212 DD:HHMM/SS UPDATE HOLD TIME REMAINING CLOCK. NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF PREFERRED LAUNCH TIME SELECTED. 16-1022 LRD BRD PREFERRED LAUNCH TIME SELECTED. SU72901 135 UPDATED SHIP COORDINATES ARE: RH SRB__________ LH SRB__________ DEPLOY RETRIEVAL SHIPS TO NEW COORDINATES AND REPORT COMPLETION. NOT PERFORMED ______ FINAL LAUNCH WINDOW DETERMINATION --------------------------------- COMPLETE -------- 912 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- G1 LAUNCH TARGET UPLINK LOADING ------------------------------- NOTE PERFORM NEXT THREE STEPS IF PASS LAUNCH TARGET UPLINK LOADING IS REQUIRED. 16-1023 *FLT NTD G1 LAUNCH TARGET UPLINK LOADING IS REQUIRED. NOT PERFORMED ______ 16-1024 NTD *FLT PERFORM PASS TARGET UPLINK LOADING. NOT PERFORMED ______ 16-1025 *FLT NTD PASS TARGET UPLINK LOADING COMPLETE. CVFS NOT PERFORMED ______ G1 LAUNCH POLYNOMIAL UPDATE --------------------------- NOTE PERFORM NEXT TWO STEPS IF LAUNCH POLYNOMIAL UPDATE IS REQUIRED. 16-1026 *FLT NTD G1 LAUNCH POLYNOMIAL UPDATE REQUIRED AND IMU RM CAPABILITY WILL SUPPORT. NOT PERFORMED ______ 16-1027 NTD *FLT PERFORM LAUNCH POLYNOMIAL UPDATE CVFS PER SEQ 117 (S0007VL5). NOT PERFORMED ______ 913 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- BFS G1 LAUNCH TARGET UPLINK LOADING ----------------------------------- NOTE PERFORM NEXT TWO STEPS IF A BFS LAUNCH TARGET UPLINK IS REQUIRED TO SUPPORT RENDEZVOUS. 16-1028 NTD *FLT PROCEED WITH TRANSMITION OF BFS LAUNCH TARGET UPDATE. NOT PERFORMED ______ 16-1029 *FLT NTD BFS LAUNCH TARGET UPDATE COMPLETE. CVFS NOT PERFORMED ______ 16-1030 OTC PLT CLEAR CAUTION AND WARNING 212 MEMORY AND VERIFY NO UNEXPECTED ERRORS. 16-1031 PLT PANEL C3 CAUTION/WARNING MEMORY SW - CLEAR 16-1032 PLT OTC CAUTION AND WARNING MEMORY 212 CLEAR COMPLETE. 914 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- EXTEND HOLD ----------- NOTE PERFORM NEXT FOUR STEPS IN EVENT HOLD MUST BE EXTENDED. 16-1033 -09M00S NTD CGLS HOLD WILL BE EXTENDED. (HOLDING) 212 CANCEL PENDING. NOT PERFORMED ______ 16-1034 NTD THE HOLD WILL BE EXTENDED. PA 212 NOT PERFORMED ______ 16-1035 -09M00S CGLS SELECT APP PG 3B (HOLDING) CURSOR CNTL SELECT CANCEL PENDING CDC REQUESTS NOT PERFORMED ______ 16-1036 JRPS STOP DISPLAY STRIP CHART RECORDERS. RESUME AT PICK UP OF COUNT. NOT PERFORMED ______ 915 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1037 -09M00S LPS JSDC VERIFY READY TO RESUME COUNT AND | (HOLDING) JCMC GO FOR LAUNCH. | JRPS NOTE PERFORM NEXT STEP IF *FLT DETERMINES RTLS ALT SETTING/ASCENT DATA OR RUNWAY REQUIRES UPDATING. ASCENT DATA CREW UPDATE (-09M) ------------------------------ 16-1038 -09M00S *FLT CDR READING OUT RTLS ALT (HOLDING) PLT SETTING/ASCENT DATA AND RUNWAY. NTD NTD OTC 212 STM NOT PERFORMED ______ IUS ASE BATTERIES ON-LINE | -------------------------- | | NOTE | | PERFORM NEXT STEP FOR | IUS MISSION AT L-20M | (STS-93). | | 16-1039 -09M00S ICTC PTC COMMANDING ASE BATTERIES ON-LINE | (HOLDING) 134 PER DOP D290-50020-27. WILL | -L20M00S REMAIN ON THROUGH LAUNCH. | | OMRSD P018JC.010 | NOT PERFORMED ______| 916 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IUS HOLD FIRE ENABLE | --------------------- | | NOTE | | PERFORM NEXT STEP FOR | IUS MISSION (STS-93). | | 16-1040 -09M00S NTD PTC PERFORM HOLD FIRE ENABLE BY CLOCK | (HOLDING) 212 AT L-15M00S. | L-18M00S PTC ICTC | 134 | NOT PERFORMED ______| | PVD/ECS PLB FLOW REDUCTION -------------------------- 16-1041 -09MOOS CPVD CONSOLE KYBD SU72903 (HOLDING) L-17M00S IF PLB PURGE FLOWRATE GREATER THAN 180 LB/MIN, ADJUST PLB FLOW RATE TO 170 LB/MIN PER APPENDIX B OF V1122 - ECS CONTINGENCY ADJUSTMENTS/OPERATIONS. NOT PERFORMED ______ 917 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1042 CPVD VERIFY VENT DOOR 6 L/H AND R/H CLOSED. 16-1043 CPVD VERIFY PLB FLOW RATE STABILIZES AT 180 LB/MIN, MAXIMUM. OMRSD V05AH0.050-D 16-1044 CPVD OTC PLB PURGE FLOWRATE SET FOR LAUNCH. NOTE PAYLOAD TEST CONDUCTORS CONCURRENCE WILL BE OBTAINED AT T-1H30M. 16-1045 -09M00S LPS WITH PAYLOAD TEST CONDUCTORS (HOLDING) CONCURRENCE INHIBIT FOLLOWING L-15M00S HIM ON GDB 4A/24A GS1A FEP. HIM PAD A OCTAL PAD B OCTAL --- ----------- ----------- 6880 056 056 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF PPOV OR MINI CAMERA IS INSTALLED. 16-1046 OTC MS2 PANEL O19 SU72905 TV TV PWR SW - ON NOT PERFORMED ______ 918 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF DTO 685 (ELETRONIC KNEEBOARD) IS INSTALLED. 16-1047 OTC MS1 TURN ON PDA. NOT PERFORMED ______ L-15M RECORDER ACTIVATION | ------------------------- | 16-1048 NTD CISL PERFORM L-15M RECORDER ACTIVATION SU72907| 212 JRPS (OIS CH 145 PER S0007VL4, SEQ 38 | *FLT AT L-15M00S). | 16-1049 CISL NTD OPS 2 RECORDER ACTIVATED. 212 IUS HOLD FIRE ENABLE | --------------------- | | NOTE | | PERFORM NEXT STEP FOR | IUS MISSION (STS-93). | | 16-1050 -09M00S ICTC ICC1 PERFORM HOLD FIRE SYSTEM ENABLE | (HOLDING) 175 PER A2811 ON OIS CH 175. | L-15M00S | NOT PERFORMED ______| 919 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LAUNCH STATUS CHECK ------------------- 16-1051 -09M00S NTD OTC VERIFY READY TO RESUME SU72909 (HOLDING) 212 TBC COUNT AND GO FOR LAUNCH PTC LPS *FLT *MIL STM *SCC SPE LRD SRO CDR 16-1052 NTD LD LAUNCH TEAM READY TO PROCEED. 920 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SPACE SHUTTLE OPERATIONS MANAGER -------------------------------- LAUNCH READINESS CHECK ---------------------- 16-1053 *OM MMT VERIFY READY TO RESUME COUNT SSPO AND GO FOR LAUNCH: SPACE SHUTTLE VEHICLE ENGINEERING SSME ROCKETDYNE RSRM THIOKOL SRB ET LOCKHEED MARTIN MICHOUD SPACE SYSTEMS LAUNCH AND LANDING KSC SPACE STATION AND SHUTTLE PAYLOADS | FCOD MISSION OPS FLIGHT MANAGER PROGRAM INTEGRATION UNITED SPACE ALLIANCE SSP DEPUTY | PROGRAM MANAGER | MSFC PROJECTS PROGRAM MGR SR AND QA DDMS | 16-1054 LD VERIFY ENGINEERING DIRECTOR'S 212 TEAM (FR2/ESA) HAS NO CONSTRAINT TO LAUNCH. 16-1055 LD SF VERIFY KSC DIRECTOR OF SAFETY AND MISSION ASSURANCE HAS NO CONSTRAINT TO LAUNCH. 921 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1056 LD PL VERIFY PAYLOAD PROCESSING DIRECTOR 212 HAS NO CONSTRAINT TO LAUNCH. 16-1057 LD *WEA VERIFY CAPE WEATHER FORECAST MEETS LAUNCH WEATHER CRITERIA. | 16-1058 LD *OM VERIFY NSTS OPERATION MANAGER'S CONCURRENCE TO PROCEED WITH LAUNCH. 16-1059 LD NTD PROCEED WITH COUNTDOWN. COUNTDOWN RE-ENTRY POINT FOR ---------------------------- INTEGRATION CONSOLE FAILURE --------------------------- BETWEEN T-9 MIN AND T-5 MIN --------------------------- 922 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLOCK START IN 4 MINUTES ------------------------ 16-1060 -09M00S NTD ALL THE COUNTDOWN CLOCK WILL START (HOLDING) 212 IN 4 MINUTES. L-13M00S TAPE SWITCH PDR SUB-SYS ----------------------- 16-1061 -09M00S LPS CPDR PERFORM TAPE SWITCH AT PDR (HOLDING) 127 SUBSYSTEM IF A NORMAL TAPE SWITCH L-13M00S HAS NOT OCCURED WITHIN PREVIOUS 5 MINUTES. NOT PERFORMED ______ 923 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF RUNWAY DESIGNATION FOR RTLS OR THE AOA SITE SELECTION HAS CHANGED FROM INITIAL CALL. 16-1062 -09M00S LSO LRD IN EVENT OF RTLS ABORT, JSTC (HOLDING) LF1 LANDING WILL BE ON RUNWAY _____ SLF L-13M00S LRD NCC (15 OR 33). FIRE CCN SEC LRD STM AOA SITE SELECTION IS ________. 135 SLF (KSC, DFRC, WSSH) STM JSTC 111 FSTM GYCC JSTC FSTC 114 FSAM JFIR *SEC NOT PERFORMED ______ NOTE PERFORM THE NEXT STEP IF KSC IS THE PRIME AOA SITE. 16-1063 LRD SRO KSC IS THE PRIME AOA SITE. | 135 MAINTAIN AIRSPACE CONTROLS UNTIL THE NEGATIVE AOA CALL. NOT PERFORMED ______ HGDS, BUHGDS AND HUMS AUTO CALS COMPLETE ---------------------------------------- 16-1064 CHGD OTC HGDS, BUHGDS AND HUMS AUTO CALS SU72852 212 AND CONFIDENCE CHECKS COMPLETE. NO ANOMALIES NOTED. 16-1065 CGLS TERM ALL OC TASKS AND GLS LOOKUPS AT INTG BEFORE CDC IS RESUMED. 16-1066 CGLS TAKE PRINTER OFF LINE. (FOR INTG CONSOLE) 16-1067 CGLS TAKE PRINTER OFF LINE. (FOR BKUP CONSOLE) 924 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLOCK START IN 3 MINUTES ------------------------ 16-1068 -09M00S NTD ALL COUNT CLOCK WILL PICK UP IN (HOLDING) 212 3 MINUTES. MARK. NOTE SRO/SCM WILL BE PERFORMING HOLDFIRE SYSTEM ENABLE ON CH 175. IT IS CRITICAL THAT SRO KNOWS THAT CDC WILL BE PICKED UP IN 2 MINUTES. FOR IUS MISSIONS: | AT APPROXIMATELY L-11 | MINUTES, IUS NAVIGATION | SYSTEM IS COMMANDED TO | NAV FLIGHT MODE AND FLIGHT | READY COMMAND IS ISSUED. | FLIGHT READY COMMAND WILL | ESTABLISH IUS CONFIGURATION | FOR LAUNCH. | | 16-1069 -09M00S NTD COUNTDOWN CLOCK WILL START IN 2 MINUTES. (HOLDING) 212 3,2,1 MARK. L-11M00S 925 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FIREX PUMP TO OP PRESS ---------------------- NOTE PERFORM NEXT STEP ONE MINUTE PRIOR TO START OF COUNTDOWN CLOCK. IF HOLD IS EXTENDED, NEXT STEP WILL BE PERFORMED AT PICKUP OF COUNTCLOCK. 16-1070 -09M00S STM JBFX BRING UP LAUNCH PAD FIREX PUMP P-1 WSSA (HOLDING) 111 TO OPERATIONAL PRESSURE WITH SU72842 NON-LAUNCH PAD PUMP P-1 AS BACKUP. 16-1071 -09M00S JBFX STM FIREX PUMP P-1 HAS STARTED. WSSA (HOLDING) 111 926 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- START VIDEO RECORDING --------------------- NOTE PERFORM NEXT TWO STEPS 1 MINUTE PRIOR TO PICKUP OF COUNT. 16-1072 -09M00S JYVS JYVO CONTACT EEC PERSONNEL AT COMM (HOLDING) 138 853-8279/8242 FOR INITIAL POSITIONING OF VAB ROOF OTV CAMERA 080. TRANSMIT VIDEO TO CDSC VIA 6TVM4100 (SW 1 OUTPUT 382). NOTE COVERAGE WILL BE FORMATION AND DEVELOPMENT OF IGNITION CLOUD THAT FORMS NORTHEAST OF PAD. EEC PERSONNEL WILL OBSERVE OTV CAMERA 080 IN ROCC. PAYLOAD COMM WILL EXTEND CIRCUIT TO ROCC. 16-1073 -09M00S JYVO JYVR START VIDEO RECORDING OF OTV COMM (HOLDING) 138 CAMERA 080. (SEE EEC FIGURE 4) 927 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLOCK START IN 1 MINUTE ----------------------- 16-1074 -09M00S NTD THE COUNTDOWN CLOCK WILL START IN (HOLDING) 212 1 MINUTE. L-10M00S MARK. IGNITER HEATER POWER REMOVAL ---------------------------- 16-1075 -09M00S TBC CPWR PERFORM SRB IGNITER HEATER SU72844 (HOLDING) 136 POWER REMOVAL. L-10M00S 16-1076 CPWR CURSOR CNTL (BDE11) AUTO SEQ - IGN XMIT CURSOR KEY - PRESS CRT VERIFY LH/RH IGN HTR CURRENT <0.5 AMPAC OMRSD S00FA0.980 16-1077 CPWR TBC IGNITER HEATER POWER REMOVAL COMPLETE. 136 928 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IUS FINAL LAUNCH CONFIGURATION | ------------------------------ | | NOTE | | NEXT STEP WILL VERIFY | COMPLETION OF FOLLOWING | IUS ACTIVITIES (L-10 MIN): | | 1. REM HEATERS ACTIVE | | 2. SCU RELAY DRIVER CHECKS | | 3. ASE BATTS ON-LINE | | 4. NAV SYSTEM TO NAV FLIGHT | MODE | | 5. FLIGHT READY COMMAND | ISSUED | | 6. POWER SWITCHING INHIBITED | | PERFORM NEXT STEP FOR IUS | MISSION (STS-93). | | 16-1078 -09M00S ICTC PTC IUS FINAL LAUNCH CONFIGURATION | (HOLDING) 134 ESTABLISHED. IUS FINAL LAUNCH | L-10M00S CONFIGURATION COMPLETE. | | OMRSD P018JC.010 | NOT PERFORMED ______| 929 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IUS HOLD FIRE ENABLE COMPLETE | ----------------------------- | | NOTE | | PERFORM NEXT STEP FOR | IUS MISSION (STS-93). | | 16-1079 -09M00S ICTC NTD HOLD FIRE SYSTEM ENABLED, IUS | (HOLDING) 212 FINAL LAUNCH CONFIGURATION COMPLETE. | L-9M45S | OMRSD P018JC.010 | NOT PERFORMED ______| | 930 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- COUNTDOWN CLOCK START --------------------- 16-1080 -09M00S NTD T-9 MINUTES AND COUNTING SU72846 (COUNTING) PA 212 16-1081 GYCC GYCJ ACTIVATE LANDING FIELD, WX COMM 117 OBSERVER AND AIRCRAFT ORBITER CIRCUITS TO TAL SITES SUPPORTING THIS MISSION. VERIFY COMPLETION. 16-1082 GYCC *VCE LANDING FIELD, WX OBSERVER AND COMM COMM AIRCRAFT ORBITER CIRCUITS COORD ACTIVATED TO TAL SITES SUPPORTING THIS MISSION. NOTE PERFORM NEXT STEP IF EXTENDED HOLD REQUIRED BETWEEN T-9 MIN AND T-5 MIN. 16-1083 NTD PERFORM HOLD OPTION NO. 1 (SEQ 28) FOR EXTENDED HOLD BETWEEN T-9 MIN AND T-5 MIN (PRIOR TO APU START). NOT PERFORMED ______ 931 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GLS AUTO SEQ START ------------------ 16-1084 -09M00S CGLS GLS AUTO SEQUENCE INITIATED. SU72848 COUNTING 16-1085 -09M00S STM JYVR START VIDEO RECORDING AS COMM 138 FOLLOWS: 1. M-II RECORDERS CAMERA 041/141, 048/148, 051/151 070/170, 071/171, TV-2, TV-4A/B, TV-5, TV-7A/B TV-11, TV-13, TV-21 A/B 2. S-VHS/VHS RECORDERS CAMERA 043/143, 049/149, 050/150 (ENGINEERING ANALYSIS) DEACTIVATE VHF WX CIRCUIT ------------------------- NOTE PERFORM NEXT TWO STEPS IF CIRCUIT ACTIVATED PER *FLT REQUEST. 16-1086 -09M00S NTD STM DEACTIVATE 2RAC534 (VHF WEATHER COMM COUNTING 212 126.65 MHZ RADIO CIRCUIT) SU72850 STM GYCC FROM ICOM-B. 111 GYCC GYCJ 117 NOT PERFORMED ______ 16-1087 STM NTD 2RAC534 (VHF WEATHER 126.65 212 MHZ RADIO CIRCUIT) NOT ACTIVE NTD *FLT TO ICOM B. NOT PERFORMED ______ 16-1088 LPS C2MC PLACE ALL PP1 AND PP2 UNITS SU72854 127 ON LINE. 932 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- STORED PROGRAM PRE-LAUNCH COMMANDS ---------------------------------- NOTE IF HOLD OCCURS AFTER TRANSMITTAL OF BFS SPC LOAD, *FLT WILL TRANSMIT SPC BUFFER CLEAR AND NEW BFS SPC LOAD BASED ON UPDATED LIFTOFF TIME IF REQUIRED. 16-1089 -08M00S *FLT TRANSMIT STORED PROGRAM PRE- SU72856 LAUNCH COMMANDS (BFS SPC LOAD). 16-1090 -08M00S *FLT VERIFY 2-STAGE BUFFER AUTO COMPARE AND EXECUTE. FUEL CELL/ESSENTIAL BUS SOURCE ON --------------------------------- 16-1091 -08M00S OTC PLT CONFIGURE FUEL CELL/ESSENTIAL SU72857 BUS SOURCE SWITCHES. 16-1092 PLT PANEL R1 POWER DISTRIBUTION ESS BUS SOURCE FC 1 SW - ON FC 2 SW - ON FC 3 SW - ON OAA RETRACT ----------- 16-1093 -07M30S CGLS ORBITER ACCESS ARM RETRACT SU72858 212 (AUTO). 16-1094 -06M20S OTC JRPS START APU STRIP CHART RECORDERS. SU72862 933 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- APU PRE-START ------------- CAUTION DURING THE PERIOD OF ENERGIZATION OF FUEL TANK ISOLATION VALVES, CAPU IS TO CONTINUOUSLY MONITOR VALVE TEMPERATURES. APU FUEL TANK ISOLATION VALVE TEMPERATURES SHALL NOT EXCEED 220 DEG F. 16-1095 -06M15S OTC PLT PERFORM APU PRE-START. SU72864 212 16-1096 -06M15S PLT PANEL R2 APU/HYD BOILER N2 SUPPLY (VERIFY) 1 SW ON 2 SW ON 3 SW ON BOILER PWR (VERIFY) 1 SW ON 2 SW ON 3 SW ON BOILER CNTLR/HTR (VERIFY) 1 SW A 2 SW A 3 SW A APU CNTLR PWR 1 SW - ON 2 SW - ON 3 SW - ON HYD CIRC PUMP (VERIFY) 1 SW GPC 2 SW GPC 3 SW GPC HYD MAIN PUMP PRESS 1 SW - LOW 2 SW - LOW 3 SW - LOW APU AUTO SHUT DOWN (VERIFY) 1 SW ENABLE 2 SW ENABLE 3 SW ENABLE 934 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1096 APU SPEED SELECT (VERIFY) CON'T 1 SW NORM 2 SW NORM 3 SW NORM APU OPERATE (VERIFY) 1 SW OFF 2 SW OFF 3 SW OFF APU FU TK VLV ENA (VERIFY) 1A CB - CLOSE 1B CB - CLOSE 2A CB - CLOSE 2B CB - CLOSE 3A CB - CLOSE 3B CB - CLOSE APU FUEL TK VLV 1 SW - OPEN 2 SW - OPEN 3 SW - OPEN VERIFY READY TO START TB'S (3) - GRAY 16-1097 PLT OTC APU'S CONFIGURED FOR START. 212 935 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- HYD PRE-APU START CHECKS (-6M) ------------------------------ 16-1098 CHYD PERFORM HYD PRE-APU START CHECKS PER S0007VL4 (SEQ 46). 16-1099 CAPU PERFORM APU PRE-START CHECK SU72866 PER S0007VL4 (SEQ 42). GO FOR APU START ---------------- 16-1100 -05M00S CGLS OTC GO FOR APU START. SU72870 212 APU START --------- NOTE CECL MONITOR FOR HEAT LOAD IMPACT IN NEXT STEP. 16-1101 -05M00S OTC PLT PERFORM APU START. SU72872 212 16-1102 -05M00S PLT PANEL R2 (VERIFY) APU/HYD READY TO START 1 TB GRAY 2 TB GRAY 3 TB GRAY APU OPERATE 1 SW START/RUN 2 SW START/RUN 3 SW START/RUN 936 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1103 PLT PANEL F8 (VERIFY) HYD PRESS 1,2,3 IND LO GREEN PANEL R2 (VERIFY) APU/HYD READY TO START 1 TB BP 2 TB BP 3 TB BP HYD MAIN PUMP PRESS 1 SW NORM 2 SW NORM 3 SW NORM PANEL F8 (VERIFY) HYDRAULIC PRESSURE 1,2,3 IND HI GREEN 16-1104 PLT PANEL R2 APU/HYD HYD CIRC PUMP 1 SW - OFF 2 SW - OFF 3 SW - OFF PANEL F7 (VERIFY) HYD PRESS LITE OFF 16-1105 PLT OTC APU START COMPLETE. 212 HYD POST APU START CHECKS (-5M) ------------------------------- 16-1106 CHYD PERFORM HYD POST APU START CHECKS PER S0007VL4 (SEQ 46) OMRSD S00FM0.175-1R 16-1107 CAPU PERFORM APU POST START CHECK PER SU72874 S0007VL4 (SEQ 42). 937 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- HTR RECONFIG ------------ 16-1108 -05M00S OTC CDR RECONFIGURE HEATERS SU72876 212 16-1109 -05M00S CDR PANEL L2A1 FLASH EVAP FEEDLINE HTR A SUPPLY SW - OFF L2A1S23 B SUPPLY SW - OFF L2A1S24 16-1110 CDR PANEL L1 | HI LOAD DUCT HTR SW - A/B (OV-102) | | 16-1111 CECL CRT PAGE A (VAG29) FES FL HTR A/B - FF/FF 16-1112 CDR OTC HEATER RECONFIGURATION COMPLETE. 16-1113 CDR PANEL C2 LEFT CRT SEL SW - 3 LT KYBD SYS SUMM BFS CRT 3 SM SYS SUMM 1 16-1114 -05M00S *SCC ALL MAINTAIN SILENCE ON NET 105 SU72878 NET UNTIL NEGATIVE RTLS VERIFIED. 105 16-1115 STM JBAC ACTIVATE COOLING TOWER SPRAY HVAA 111 SYSTEM. 16-1116 -05M00S JCFM START PMS RECORDERS. 938 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB JOINT HEATER ALARM INHIBIT ------------------------------ 16-1117 -05M00S CPWR PFP (BWE11) PFPK 5 KEY - PRESS LED 5 VERIFY ALARM INH AUTO ET OPS DEACTIVATION ------------------------ 16-1118 CPWR PFP (BWE08) PFPK 3 KEY - PRESS LED 3 CRT VERIFY AUTO ET OPS INH TERM LOX REPLENISH ------------------ 16-1119 -04M55S CGLS TERMINATE LOX REPLENISH. SU72880 NOTE IF HOLD IS PENDING AFTER LOX TERM REPLENISH TIME OF T-5M AND LOX DID NOT TERMINATE REPLENISH, PERFORM NEXT STEP 55 SECS (FOR HOLD AT T-4M), 2M00S (FOR HOLD AT T-2M55S) OR 4M24S (FOR HOLD AT T-31 SEC) BEFORE RESUMING FROM THE HOLD SO THAT LOX TERM REPLENISH OCCURS AT PROPER L-TIME. 16-1120 CGLS PFP (SLP01) PFPK3 (CONTINGENCY LEDS) - PRESS PFPK1 (TERM LOX REPL) - PRESS PFPK6 (EXEC TERM LOX REPL) - PRESS NOT PERFORMED ______ 939 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1121 CSME CRT (VAE38) VERIFY E-1, E-2 AND E-3 MFV CURRENT INDICATES 0. OMRSD S00FM0.040 NOTE | | PERFORM NEXT TWO STEPS IF | THE T-9 MIN HOLD WAS | EXTENDED OR THE COUNTDOWN | CLOCK WAS HELD AFTER T-9 MIN. | | 16-1122 NTD *FLT PROVIDE UPDATE TO LOX DRAINBACK | 212 HOLD TIME (PERFORMANCE) | | _____MIN _____SEC | NOT PERFORMED ______| | 16-1123 NTD ALL HOLD TIME REMAINING IS: | 212 | _____MIN _____SEC | NOT PERFORMED ______| 940 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SSME PURGE SEQUENCE - 4 ----------------------- 16-1124 -04M00S CGLS SSME PURGE SEQUENCE 4 (AUTO) SU72882 212 LO2 PRESSURIZATION ------------------ 16-1125 -02M55S CGLS ET LO2 PRESSURIZATION (AUTO). SU72892 212 | SSME GN2 PURGE TERMINATION -------------------------- 16-1126 CSME CRT (VAE38) VERIFY GN2 PURGE TERMINATES OMRSD S00FM0.350-1 16-1127 CSME CRT (VAE38A) VERIFY GN2 HEATER PANEL OUTLET TEMP AMBIENT (LESS THEN 90 DEG F) FOR PRECEDING 2.5 HOURS MINIMUM. OMRSD S00FD0.095-B 941 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLEAR CAUTION AND WARNING MEMORY -------------------------------- 16-1128 -02M30S OTC PLT CLEAR CAUTION AND WARNING MEMORY SU72896 212 VERIFY NO UNEXPECTED ERRORS 16-1129 PLT PANEL C2 CRT 3 MAJ FUNC SW - GNC R KYBD (BFS) FAULT SUMM R KYBD (BFS) SPEC 99 PRO (CLEAR FSP) RESUME SYS SUMM CRT 3 GNC SYS SUMM 1 (BFS) 16-1130 -02M30S PLT PANEL C2A2 R CRT SEL SW - 2 R KYBD FAULT SUMM R KYBD SPEC 99 PRO (CLEAR FSP) RESUME CRT 2 GNC SYS SUMM 1 PANEL C2 R CRT SEL SW - 3 942 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1131 -02M30S PLT PANEL C3 CAUTION/WARNING MEMORY SW - CLEAR 16-1132 -02M30S PLT OTC CAUTION AND WARNING CLEAR COMPLETE. 212 CLOSE VISORS ------------ 16-1133 -02M00S OTC FLT CLOSE AND LOCK YOUR VISORS AND SU72898 CREW INITIATE O2 FLOW. CONFIG LDBM SUB-SYS ------------------- 16-1134 -02M00S CLDB CONFIGURE LDBM SUBSYSTEM DUAL BUS - ACCEPT 16-1135 -02M00S JBWC VERIFY AUTO START OF PRINTER WSSA PLOTTERS. SKELETON LFA/LFB TO REMAIN DISPLAYED THRU T-0. (P/P'S MAY BE SECURED FOR RECYCLES OR EXTENDED HOLDS) LH2 TANK PRESSURIZATION ----------------------- 16-1136 -01M57S CGLS ET LH2 PRESSURIZATION (AUTO). SU72900 212 OMRSD S00FM0.400-1 (SSH03) OMRSD S00FM0.380-1 (SSH03) OMRSD S00FM0.390 (SSH03) OMRSD S00FM0.450-1 (SSH03) 16-1137 -01M30S NTD ONE MINUTE 30 SECONDS. 212 16-1138 -01M00S NTD ONE MINUTE. 212 943 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GLS GO FOR AUTO SEQ START ------------------------- NOTE FROM THIS TIME UNTIL LAUNCH OR ABORT APPENDIX M (SRB TIME /CYCLE DATA SHEET) DATA WILL BE AFFECTED. 16-1139 -00M31S CGLS GLS GO FOR AUTO SEQ START (AUTO). SU72904 212 ARM CUTOFF ---------- 16-1140 -00M31S CGLS PFPK SLP01 - PRESS PFPK CUTOFF - PRESS VERIFY CUTOFF ARMED 944 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORBITER VENT DOOR SEQ START --------------------------- 16-1141 -00M28S CPVD ORBITER VENT DOORS LAUNCH CONFIGURATION SEQUENCING START. 16-1142 -00M25S NTD TWENTY FIVE 212 16-1143 -00M20S NTD TWENTY 212 16-1144 -00M15S NTD FIFTEEN 212 16-1145 -00M10S NTD TEN 212 GLS GO FOR M.E. START --------------------- 16-1146 -00M10S CGLS GLS GO FOR MAIN ENGINE START. 212 NOTE PERFORM NEXT STEP ONLY IF DISK RECORDING ERRORS ARE OCCURRING AT THIS TIME. 16-1147 -00M08S CPDR INHIBIT BULK DISC RECORDING PDR INFOTON KYBD #TMRC,D RTN KEY - PRESS NOT PERFORMED ______ 945 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MAIN ENGINE START ----------------- NOTE IF PC IS LESS THAN 90 PCT AT 4.60 SEC AFTER START CMD OR ANY MAIN ENG STATUS LITE AMBER PRIOR TO SRB IGNITION, SEQUENTIAL SHUTDOWN OCCURS. 16-1148 -00M06.60S CSME MAIN ENGINE 3 START CMD (AUTO) SU72908 -00M06.48S MAIN ENGINE 2 START CMD (AUTO) -00M06.36S MAIN ENGINE 1 START CMD (AUTO) 16-1149 -00M06S PLT PANEL F7 MPS PRESS PC (3) INCREASING TO >90 PCT SRB IGNITION/LIFTOFF -------------------- 16-1150 00M00S NTD T-0 SRB IGNITION. SU72910 212 NOTE AT UMBILICAL DISCONNECT THE FIRING ROOM WILL BE AUTO-SWITCHED TO RF DATA - A MOMENTARY DATA LOSS MAY OCCUR. THE LDBA AND LDBS FEP WILL GO TO NO GO MODE. DESELECT KSC U/L ---------------- NOTE PERFORM NEXT STEP AT SRB IGNITION. 16-1151 *MIL DESELECT KSC UPLINK ON ASTRO COMM UHF, A/G1, A/G2. 16-1152 NTD TEST TEAM MONITOR A/G COMM ON 212 OIS CH 217/218 AND REMAIN ACTIVE ON CH 212. 946 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FIGURE 16-01 - ABORT FLOW CHART (FOR REFERENCE ONLY) 947 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM RSLS ABORT SAFING ANYTIME AFTER SSME 3 START COMMAND IS ISSUED (T-6.6 SEC) BY THE RSLS AND A RSLS ABORT OCCURS. 16-1153 RSLS ABORT SAFING ----------------- NOT PERFORMED ______ NOTE RSLS ABORT CRITERIA: (A) CUTOFF AFTER ENGINE START SEQUENCE INITIATED, AND PRIOR TO SRB IGNITION. (B) PASS GPC'S IN MM 101 (C) LDB INTEGRITY/POLLING MAINTAINED (D) BFS NOT ENGAGED (BUT MAY HAVE MODED TO 102) 16-1154 NTD PERFORM RSLS ABORT SAFING OPERATIONS AS FOLLOWS: 1. CGLS NTD CUTOFF THE RSLS ABORT FLAG IS ON GLS SAFING (IN PROGRESS/NOT RUNNING) NOTE PERFORM NEXT SUBSTEP IF INVALID DATA/CMD PATH FAILURE IS DETECTED. 2. CGLS NTD (PASS)/(BFS)/(OI) INVALID (LDB DOWN) NOT PERFORMED ______ SS2 3. CGLS NTD BFS______ PASS______ LDB______ 948 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 4. SPE NTD PERFORM RSLS ABORT. CON'T GLS SAFING __________ (IN PROGRESS/NOT RUNNING) NOTE PERFORM NEXT THREE SUBSTEPS IF THE GLS IS NOT RUNNING AND VEHICLE HAS NOT LIFTED OFF. 5. SPE CGLS FORCE SAFING TO CONTINUE. NOT PERFORMED ______ SS5 6. CGLS PFPK5 RS ABORT PFPK6 RS ABORT EXEC NOT PERFORMED ______ SS6 7. CGLS NTD GLS SAFING IS IN PROGRESS. NOT PERFORMED ______ SS7 949 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 LPS DATA PATH CHECKLIST CON'T ----------------------- NOTE PERFORM NEXT THREE SUBSTEPS FOR A SUSPECTED COMMAND/DATA PATH INTEGRITY FAILURE. 8. NTD LPS REPORT FEP DATA VALIDITY OI___ GPC___ LDB___ GS(1,2,3)___ NOT PERFORMED ______ SS8 9. NTD CDPS REPORT GPC DOWNLIST/LDB STATUS. NOT PERFORMED ______ SS9 10. NTD CISL REPORT PCMMU/OI STATUS. NOT PERFORMED ______ SS10 NOTE PERFORM NEXT SUBSTEP AS SOON AS POSSIBLE AFTER AN RSLS ABORT HAS BEEN DECLARED. 11. JBFX 1. TERMINATE MLP SIDE 1 WSSA LAUNCH COOLING SPRAY. 2. TERMINATE FSS LAUNCH COOLING SPRAYS. 950 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 NOTE CON'T PERFORM NEXT THREE SUBSTEPS IF GLS SAFING IS NOT IN PROGRESS. 12. NTD CGSS EXTEND OAA. 212 NOT PERFORMED ______ SS12 13. NTD CECL ESTABLISH ORBITER COOLING FLOW. 212 NOT PERFORMED ______ SS13 14. NTD CEPD POWER DOWN GROUND PIC RACKS. NOT PERFORMED ______ SS14 15. NTD CDR PERFORM BFS SAFING CDR PANEL O6 GENERAL PURPOSE COMPUTER MODE 5 SW - HALT 16. CGLS NTD ENGINE STATUS: E1: __________ E2: __________ E3: __________ (NOMINAL IS POST SHUTDOWN/STANDBY) NOTE GO TO SS23 IF ALL THREE ENGINES ARE IN POST SHUTDOWN STANDBY. 17. CGLS NTD HOLDING FOR ENGINE STATUS. NOT PERFORMED ______ SS17 951 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 NOTE CON'T IF GLS CANNOT VERIFY POST SHUTDOWN/STANDBY WITH MCC < 50 PSIA, SAFING WILL NOT CONTINUE UNTIL A CCME AND CSME GO IS GIVEN OR THE ABOVE CRITERIA IS SATISFIED. 18. NTD CSME REPORT ENGINE STATUS: CCME E1:______ E2:______ E3:______ NOT PERFORMED ______ SS18 NOTE GO TO SS23 IF ALL THREE ENGINES ARE IN POST SHUTDOWN STANDBY, IF GLS SAFING IS IN PROGRESS AND DOWNLIST DATA IS VALID. GO TO SS20 IF ALL THREE ENGINES ARE IN POST SHUTDOWN STANDBY, IF GLS SAFING IS NOT IN PROGRESS AND DOWNLIST DATA IS INVALID. 952 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 SSME COMMAND PATH FAILURE CON'T ------------------------- NOTE PERFORM NEXT FOUR SUBSTEPS FOR MAIN ENGINE COMMAND PATH FAILURE. CONDITIONS FOR COMMAND PATH FAILURE: ENGINE PHASE - MAINSTAGE OTV - ENGINE RUNNING OR EIU PRI AND SEC PORT - BYPASSED OTV - ENGINE RUNNING 19. CSME NTD THERE HAS BEEN AN SSME COMMAND CCME PATH FAILURE, HAVE PLT PERFORM NTD PLT (E-1 CENTER, E-2 LEFT OR E-3 RIGHT) ENGINE CONTROLLER SHUTDOWN. A. CENTER ENGINE 1 POWERDOWN PANEL R2 MPS ENGINE PWR CTR AC1 SW - OFF CTR AC2 SW - OFF NOT PERFORMED ______ SSA DELAY 2 SECONDS B. LEFT ENGINE 2 POWERDOWN PANEL R2 MPS ENGINE PWR LEFT AC2 SW - OFF LEFT AC3 SW - OFF NOT PERFORMED ______ SSB DELAY 2 SECONDS 953 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 C. RIGHT ENGINE 3 POWERDOWN CON'T PANEL R2 MPS ENGINE PWR RIGHT AC3 SW - OFF RIGHT AC1 SW - OFF NOT PERFORMED ______ SSC NOT PERFORMED ______ SS19 20. CSME NTD ALL ENGINES SHUT DOWN. 212 HYDRAULICS NO LONGER REQUIRED. NOT PERFORMED ______ SS20 21. NTD CGLS ALL ENGINES SHUTDOWN, GLS CONTINUE SAFING. NOT PERFORMED ______ SS21 22. CGLS PFPK5 (FORCE ENG SAFING) - PRESS NOT PERFORMED ______ SS22 23. CGLS NTD SRB IGNITION/SEP PIC'S SAFED/CHARGED (NOT SAFED). (PIC CAP VOLTS 0 +/- 1.5 V) NOTE PERFORM NEXT TWO SUBSTEPS IF SRB IGNITION PICS ARE CHARGED (NOT SAFED). 24. NTD MS1 PERFORM SRB SAFING PANEL O17 ROW D MEC 1 SW - OFF 2 SW - OFF NOT PERFORMED ______ SS24 954 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 25. MS1 NTD MEC POWER DOWN COMPLETE. CON'T NOT PERFORMED ______ SS25 26. CGLS NTD GLS - GO FOR APU SHUTDOWN. 27. NTD PLT PERFORM APU SHUTDOWN 28. PLT NTD APU SHUTDOWN COMPLETE. 29. LPS VERIFY GS (1,2,3) FEP DATA VALIDITY. (SIM) SSME HEAT SHIELD WATER ACTIVATION --------------------------------------- NOTE GLS INITIATES SSME H/S FIREX WATER DURING PRIMARY POST ABORT SAFING. NEXT STEP IS PERFORMED TO BACK UP GLS AND READY THE SYSTEM FOR VALVE CLOSURE. 30. CMPL PFP (SAE02) 1. SAE02 - PRESS 2. SSME HEAT SHIELD - PRESS 3. SSME HS OPEN - PRESS 4. VERIFY BOTH SSME HS OPEN PFPK LIGHTS ON OMRSD S00E00.137-1 31. JBFX NTD ALL LAUNCH COOLING SPRAYS WSSA TERMINATED. 955 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 32. NTD CMPL VERIFY LO2 BLEED PATH WAS CON'T CLOX ESTABLISHED (WITHIN 2 MIN OF ENGINE SHUTDOWN) OR LOX DRAIN WAS INITIATED (WITHIN 9 MIN). OMRSD S00E00.B90-1 33. CMPS START LH2 TOPPING LINE DRAIN PER OMI S1004 POST IGNITION SAFING. OMRSD S00E00.B95-1 34. NTD CMPL FIRE DETECTOR STATUS (TRIPPED/NOT TRIPPED): NO. --- 44 PRI (LH2 DISC) __________ 44 SEC (LH2 DISC) __________ 45 PRI (LH2 DISC) __________ 45 SEC (LH2 DISC) __________ 35. CGLS NTD FIRE DETECTOR STATUS (TRIPPED/NOT TRIPPED): NO. --- 35 PRI (LH2 TSM) __________ 35 SEC (LH2 TSM) __________ 36 PRI (LT AFT) __________ 36 SEC (LT AFT) __________ 37 PRI (RT AFT) __________ 37 SEC (RT AFT) __________ 38 PRI (HT SHIELD) __________ 38 SEC (HT SHIELD) __________ 39 PRI (HT SHIELD) __________ 39 SEC (HT SHIELD) __________ 36. NTD CMPL REPORT WATER DELUGE STATUS: 212 HEAT SHIELD __________ (ON/OFF) SKIN __________ (ON/OFF) T-0 __________ (ON/OFF) 956 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 37. CGLS NTD GLS PRIMARY SAFING COMPLETE. READY CON'T FOR TRANSITION TO G9. 38. CDPS CURSOR CNTL (SAS01 PG-B) RSLS HOLD/ABORT DD (VAS61) XMIT CURSOR KEY - PRESS PFK-5 KEY - PRESS 39. CHGD CONTINUE MONITORING AFT FUSELAGE UNTIL LO2/LH2 DRAIN COMPLETE. 40. NTD CLHY REPORT LEAK DETECTION STATUS: (REPORT ANY MAJOR LEAKS) 41. CPRP NTD CRITICAL MPS SAFING COMPLETE. LH2 ET TANK VENTED TO AMBIENT PER S1004. MPS LH2 TOPPING LINE DRAIN IS COMPLETE. MPS LO2 BLEED PATH HAS BEEN EXTABLISHED OR LOX DRAIN INITIATED. OMRSD S00E00.B90-1 OMRSD S00E00.B95-1 OMRSD S00E00.130-1 42. NTD CGSS VERIFY OAA EXTENDED AND LOCKED. REPORT STATUS OF EMERGENCY EGRESS TEMPERATURE AND FLAME DETECTORS. 43. CMPL NTD MPS/SSME PARAMETERS INDICATE THAT NO PROPELLANT LEAKAGE/FIRE EXISTS. REQUEST CONCURRENCE TO TERMINATE SSME HEAT SHIELD FIREX WATER FLOW. 957 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1154 44. CMPL PFP (SAE02) CON'T 1. SSME HS CLOSED - PRESS 2. VERIFY ALL PFPK LITES OFF. 45. CMPL NTD POST ABORT SSME HEAT SHIELD FIREX WATER FLOW HAS BEEN TERMINATED. 46. NTD ALL AN RSLS ABORT HAS OCCURRED. PRELIMINARY SAFING IS COMPLETE. ALL SYSTEMS STANDBY FOR POST ABORT SAFETY CHECKS PAGE _____. RSLS ABORT SAFING COMPLETE -------------------------- 958 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM BFS ENGAGE ABORT SAFING IF A GLS GO FOR SSME START HAS BEEN INITIATED (T-10 SEC) AND A BFS ENGAGE OCCURS. 16-1155 BFS ENGAGE ABORT SAFING ----------------------- NOT PERFORMED ______ NOTE BFS ENGAGE ABORT CRITERIA: (A) PASS GPC'S IN S/W HALT (B) TSM'S REMAIN CONNECTED (C) GPC/LDB POLLING HAS TERMINATED (D) BFS MAY HAVE MODED TO MM102 WARNING IF IN MM102, THE BFS MAY INITIATE SRB SEPARATION IF ONE OF THE FOLLOWING FLIGHT INITIATED ACTIONS DOES NOT OCCUR PRIOR TO T-0 PLUS 100 SECONDS. A. MEC 1 AND 2 POWER OFF B. BFS GPC HALTED OR DISENGAGED 16-1156 NTD PERFORM BFS ENGAGE ABORT SAFING OPERATIONS AS FOLLOWS: 1. CGLS NTD CUTOFF BFS ENGAGED INDICATION. BFS IN ______, PASS AND LDB INVALID. GLS SAFING NOT RUNNING. 959 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 2. SPE NTD PERFORM BFS ENGAGE ABORT. CON'T GLS SAFING PASS DOWNLIST DATA AND LDB COMMANDING ARE NOT AVAILABLE. 3. SPE CGLS FORCE SAFING START 4. CGLS PFPK5 RS ABORT SAFING PFPK6 EXEC RS ABORT SFNG 5. CGLS NTD GLS SAFING IS IN PROGRESS 6. NTD MS1 PERFORM SRB SAFING MS1 PANEL O17 ROW D MEC 1 SW - OFF 2 SW - OFF NOTE PERFORM NEXT SUBSTEP AS SOON AS POSSIBLE AFTER A BFS ENGAGE ABORT HAS BEEN DECLARED. 7. JBFX 1. TERMINATE MLP SIDE 1 WSSA LAUNCH COOLING SPRAY. 2. TERMINATE FSS LAUNCH COOLING SPRAYS. NOTE PERFORM NEXT THREE SUBSTEPS IF GLS SAFING IS NOT IN PROGRESS. 8. NTD CGSS EXTEND OAA. 212 NOT PERFORMED ______ SS8 9. NTD CECL ESTABLISH ORBITER COOLING FLOW. 212 NOT PERFORMED ______ SS9 960 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 10. NTD CEPD POWER DOWN GROUND PIC RACKS. CON'T NOT PERFORMED ______ SS10 NOTE PERFORM NEXT SUBSTEP IF BFS MODE IS 102. 11. NTD CDR PANEL C3 MAIN ENGINE SHUTDOWN CTR PB - PRESS, RELEASE (DELAY 2 SECONDS) LEFT PB - PRESS, RELEASE (DELAY 2 SECONDS) RIGHT PB - PRESS, RELEASE VERIFY THREE ENGINE STATUS LITES RED NOT PERFORMED ______ SS11 961 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 SSME COMMAND PATH FAILURE CON'T ------------------------- NOTE PERFORM NEXT SUBSTEP IF BFS MODE IS 101 OR ANY ENGINE IS RUNNING. CONDITIONS FOR COMMAND PATH FAILURE: ENGINE PHASE - MAINSTAGE OTV - ENGINE RUNNING OR EIU BFS PRI AND SEC PORT - BYPASSED OTV - ENGINE RUNNING 12. CSME NTD THERE HAS BEEN AN SSME COMMAND PATH CCME FAILURE, HAVE PLT PERFORM (E-1 CENTER, NTD PLT E-2 LEFT OR E-3 RIGHT) ENGINE CONTROLLER SHUTDOWN. A. CENTER ENGINE 1 POWERDOWN: PANEL R2 MPS ENGINE PWR CTR AC1 SW - OFF CTR AC2 SW - OFF NOT PERFORMED ______ SSA DELAY 2 SECONDS B. LEFT ENGINE 2 POWERDOWN: PANEL R2 MPS ENGINE PWR LEFT AC2 SW - OFF LEFT AC3 SW - OFF NOT PERFORMED ______ SSB DELAY 2 SECONDS 962 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 C. RIGHT ENGINE 3 POWERDOWN: CON'T PANEL R2 MPS ENGINE PWR RIGHT AC3 SW - OFF RIGHT AC1 SW - OFF NOT PERFORMED ______ SSC NOT PERFORMED ______ SS12 13. CSME NTD ALL SSME'S ARE SHUTDOWN. HYDRAULICS ARE NO LONGER REQUIRED. 14. NTD CGLS PFPK5 FORCE ENG SAFING 15. CGLS NTD GLS IS GO FOR APU SHUTDOWN. 16. NTD PLT PERFORM APU SHUTDOWN. 17. PLT NTD APU SHUTDOWN COMPLETE. 963 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 SSME HEAT SHIELD WATER ACTIVATION CON'T --------------------------------- NOTE GLS INITIATES SSME H/S FIREX WATER DURING PRIMARY POST ABORT SAFING. NEXT STEP IS PERFORMED TO BACK UP GLS AND READY THE SYSTEM FOR VALVE CLOSURE. 18. CMPL PFP (SAE02) 1. SAE02 - PRESS 2. SSME HEAT SHIELD - PRESS 3. SSME HS OPEN - PRESS 4. VERIFY BOTH SSME HS OPEN PFPK LIGHTS ON OMRSD S00E00.137 19. JBFX NTD ALL LAUNCH COOLING SPRAYS WSSA HAVE BEEN TERMINATED. 964 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 GPC/LDB RECOVERY CON'T ---------------- 20. NTD CDPS PERFORM GPC/LDB RECOVERY. CDPS CDR PANEL O6 GENERAL PURPOSE COMPUTER MODE 5 SW - HALT 4 SW - HALT 3 SW - HALT 2 SW - HALT 1 SW - HALT PANEL F6 BFC SW - DISENGAGE, REL PANEL O6 IPL SOURCE SW - MMU 1 GENERAL PURPOSE COMPUTER POWER 1 SW - OFF 2 SW - OFF 3 SW - OFF 4 SW - OFF 5 SW - OFF 1 SW - ON PANEL C3 BFC CRT DISPLAY SW - OFF PANEL O6 GENERAL PURPOSE COMPUTER INITIAL PROGRAM LOAD 1 PB - PRESS, REL MODE 1 TB IPL THEN BP (WITHIN 2 MIN) 1 SW - STBY 1 TB RUN (WITHIN 2 MIN) 1 SW - RUN IPL SOURCE SW - OFF OUTPUT 1 TB GRAY 21. CGLS NTD GLS GROUND SYSTEMS SAFING COMPLETE. 965 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 22. NTD CDPS CONTINUE WITH LDB RECOVERY. CON'T CDPS CDR L KYBD SPEC 1 PRO ITEM 50 EXEC (ENABLES POLLING) RESUME ITEM 1+9 EXEC ITEM 3+0+0+0 EXEC ITEM 8+1+1+1 EXEC ITEM 17+1+1+1 EXEC OPS 901 PRO 23. CDPS NTD GPC 1 IN G9 AND LDB POLLING ENABLED. LPS DATA PATH CHECKLIST ----------------------- 24. NTD LPS REPORT FEP DATA VALIDITY OI___ GPC___ LDB___ GS(1,2,3)___ 25. NTD CDPS REPORT GPC/LDB STATUS. 26. NTD CISL REPORT PCMMU/OI STATUS. NOTE GLS SAFING WILL BE REPEATED AFTER POLLING ESTABLISHED TO COMPLETE SAFING OF VEH SYSTEMS. 27. SPE CGLS REPEAT GLS SAFING. CGLS PFPK1 REPEAT SAFING PFPK6 EXECUTE SAFING 28. CGLS NTD GLS SAFING IS IN PROGRESS. 966 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 NOTE CON'T PERFORM NEXT SUBSTEP IF GLS HANGS AT ENGINE STATUS. 29. CGLS PFPK5 FORCE ENG SAFING NOT PERFORMED ______ SS28 30. NTD CMPL INITIATE LOX DRAIN. CLOX OMRSD S00E00.B90-1 31. CMPS START LH2 TOPPING LINE DRAIN PER OMI S1004 POST IGNITION SAFING. OMRS S00E00.B95-1 32. NTD CMPL MPS FIRE DETECTOR STATUS: (TRIPPED/NOT TRIPPED) NO. --- 44 PRI (LH2 DISC) __________ 44 SEC (LH2 DISC) __________ 45 PRI (LH2 DISC) __________ 45 SEC (LH2 DISC) __________ 33. CGLS NTD MPS FIRE DETECTOR STATUS: (TRIPPED/NOT TRIPPED) NO. --- 35 PRI (LH2 TSM) __________ 35 SEC (LH2 TSM) __________ 36 PRI (LT AFT) __________ 36 SEC (LT AFT) __________ 37 PRI (RT AFT) __________ 37 SEC (RT AFT) __________ 38 PRI (HT SHIELD) __________ 38 SEC (HT SHIELD) __________ 39 PRI (HT SHIELD) __________ 39 SEC (HT SHIELD) __________ 967 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 34. CMPL NTD REPORT WATER DELUGE STATUS: CON'T HEAT SHIELD __________ (ON/OFF) SKIN __________ (ON/OFF) T-0 __________ (ON/OFF) 35. CGLS NTD GLS PRIMARY SAFING COMPLETE. (SECOND PASS) 36. NTD CLHY LEAK DETECTOR AND FIRE DETECTOR STATUS: (REPORT ANY MAJOR LEAKS DETECTED) 37. CHGD CONTINUE MONITORING AFT FUSELAGE UNTIL LO2/LH2 DRAIN COMPLETE. OMRS S00FA0.435 38. CPRP NTD CRITICAL MPS SAFING COMPLETE. LH2 ET TANK VENTED TO AMBIENT PER S1004. MPS LH2 TOPPING LINE DRAIN IS COMPLETE. LOX DRAIN INITIATED. OMRSD S00E00.B90-1 OMRSD S00E00.B95-1 OMRSD S00E00.130-1 39. NTD CGSS VERIFY OAA EXTEND AND LOCKED. REPORT STATUS OF EMERGENCY EGRESS TEMPERATURE AND FLAME DETECTORS. 40. CMPL NTD MPS/SSME PARIMETERS INDICATE THAT NO PROPELLANT LEAKAGE/FIRE EXISTS. REQUEST CONCURRENCE TO TERMINATE SSME HEAT SHIELD FIREX WATER FLOW. 41. CMPL PFP (SAE02) 1. SSME HS CLOSED - PRESS 2. VERIFY ALL PFPK LITES OFF. 968 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1156 42. CMPL NTD POST ABORT SSME HEAT SHIELD FIRES CON'T WATER FLOW HAS BEEN TERMINATED. 43. NTD ALL A BFS ENGAGED ABORT HAS OCCURRED. PRELIMINARY SAFING COMPLETE. ALL SYSTEMS STANDBY FOR POST ABORT SAFETY CHECKS PAGE _____. BFS ENGAGED ABORT SAFING COMPLETE --------------------------------- 969 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LPS/RSLS HOLD ------------- NOTE THIS SECTION PERFORMED ONLY IF LPS/RSLS HOLD OCCURS. NOT PERFORMED ______ 16-1157 NTD PERFORM LPS/RSLS HOLD SAFING OPERATIONS AS FOLLOWS: NOTE IF GLS SAFING IS NOT IN PROGRESS PERFORM CUTOFF. 1. NTD CGLS PFPK5 (CUTOFF) - PRESS VFY PFPK5 LIGHT YELLOW NOT PERFORMED ______ SS1 2. CGLS PFPK6 (EXECUTE CUTOFF) - PRESS VFY SAFING IN PROGRESS NOT PERFORMED ______ SS2 3. CGLS CUTOFF LPS/RSLS HOLD HAS OCCURRED. GLS SAFING (IN PROGRESS/NOT RUNNING) NOTE PERFORM NEXT SUBSTEP IF INVALID DATA/CMD PATH FAILURE IS DETECTED. 4. CGLS (PASS)/(BFS)/(OI) INVALID (LDB DOWN) NOT PERFORMED ______ SS4 970 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1157 5. CGLS BFS______ PASS______ LDB______ CON'T 6. SPE NTD WE HAVE AN LPS/RSLS HOLD GLS SAFING__________ (IN PROGRESS/ NOT RUNNING) NOTE GO TO SEQ 18 IF GLS SAFING IS IN PROGRESS. PERFORM NEXT THREE SUBSTEPS IF GLS IS NOT RUNNING. 7. SPE CGLS FORCE SAFING TO CONTINUE. NOT PERFORMED ______ SS7 8. CGLS PFPK3 RS HOLD PFPK6 RS ABORT EXEC NOT PERFORMED ______ SS8 9. CGLS NTD GLS SAFING IS IN PROGRESS. NOT PERFORMED ______ SS9 LPS DATA PATH CHECKLIST ----------------------- NOTE PERFORM NEXT THREE SUBSTEPS FOR A SUSPECTED COMMAND/DATA PATH INTEGRITY FAILURE. 10. NTD LPS REPORT FEP DATA VALIDITY OI___ GPC___ LDB___ GS(1,2,3)___ NOT PERFORMED ______ SS10 971 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1157 11. NTD CDPS REPORT GPC DOWNLIST/LDB STATUS. CON'T NOT PERFORMED ______ SS11 12. NTD CISL REPORT PCMMU/OI STATUS. NOT PERFORMED ______ SS12 NOTE PERFORM NEXT THREE SUBSTEPS IS GLS SAFING IS NOT IN PROGRESS. 13. NTD CGSS EXTEND OAA. NOT PERFORMED ______ SS13 14. NTD CECL ESTABLISH ORBITER COOLING FLOW. NOT PERFORMED ______ SS14 15. NTD CEPD POWER DOWN GROUND PIC RACKS. NOT PERFORMED ______ SS15 16-1158 NTD ALL PERFORM SEQUENCE 18. 212 LPS/RSLS HOLD COMPLETE ---------------------- 972 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PEFORM POST ABORT SAFETY CHECKS FOLLOWING THE ABORT SAFING FOR: 1. RSLS ABORT 2. BFS ENGAGE ABORT 16-1159 POST ABORT SAFETY CHECKS ------------------------ NOT PERFORMED ______ 16-1160 NTD PERFORM POST ABORT SAFETY CHECKS. 1. NTD CISL VERIFY ORBITER OI PCM DATA VALID. 2. NTD CDPS VERIFY ORBITER DOWNLIST DATA VALID. VERIFY LDB POLLING ACTIVE. 3. NTD CCME VERIFY ENGINE DATA VALID AND ENGINE COMMAND PATHS GOOD. 4. NTD CSME VERIFY ALL ENGINE PRESSURES AND TEMPERATURES APPEAR NORMAL. 5. NTD CSME VERIFY NO ENGINE LEAK INDICATIONS. 6. NTD CMPL VERIFY NO INDICATION OF FIRE ON FD 36, 37, 38, 39 AT AFT ORBITER AREA. 7. NTD CMPL VERIFY LOX BLEED PATH ESTABLISHED OR S1003 APPENDIX Z "LOSS OF BLEED FLOW" (OXYGEN 67) INITIATED. 8. NTD CLHY VERIFY NO UNEXPECTED FIRE DETECTORS TRIPPED. 9. NTD CLHY VERIFY NO SIGNIFICANT LEAKS ON MLP. CROSS-COUNTRY LINES, TSM, STORAGE AREA OR ET VENT SYSTEM. 10. NTD CLHY VERIFY LH2 TANK PRESSURE STABLE. 973 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 16-1160 11. NTD CLOX VERIFY OTV INDICATES NO FIRE OR CON'T LEAKS ON CROSS-COUNTRY LINES, STORAGE AREA, MLP OR TSM. 12. NTD CLOX VERIFY ET LOX TANK PRESSURE STABLE. 13. NTD CPVD VERIFY GN2 PURGE INTERFACE PRESSURES ARE NOMINAL AND VENT DOORS IN NORMAL PURGE CONFIGURATION. 14. NTD CHGD VERIFY NO INDICATION OF HYDROGEN LEAKS IN AFT FUSELAGE. 15. NTD CHGD VERIFY NO INDICATION OF OXYGEN LEAKS IN AFT FUSELAGE. 16. NTD CGSS VERIFY NO INDICATIONS OF FIRE ON CREW ESCAPE ROUTE. 17. NTD CAPU VERIFY APU'S ARE SHUTDOWN AND NO LEAKAGE INDICATIONS. 18. NTD CBHY VERIFY HPU'S ARE SHUTDOWN AND NO LEAKAGE INDICATIONS. HPU RUN TIME NOT TO EXCEED 160 SEC. 19. NTD CPWR VERIFY SRB IGNITION S&A'S SAFE. 20. NTD CEPD IF CUTOFF OCCURED VERIFY GROUND PIC RACK POWERED DOWN. 21. NTD COOS VERIFY ALL OX/FUEL TANK PRESSURES AND TEMPS STABLE. 22. NTD CBRS VERIFY RANGE SAFETY INHIBITS ON. 23. NTD ALL ABORT SAFETY CHECKS COMPLETE. PROCEED TO "RECYCLE - CONTROL SEQUENCE" (SEQ 18). POST ABORT SAFETY CHECKS COMPLETE --------------------------------- 974 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0000 POST LAUNCH SECURING/RTLS CONTINGENCY ------------------------------------- NOTE DO NOT PERFORM THIS SEQUENCE IF ABORT/RECYCLE OCCURS THAT RESULTS IN A 24 HOUR OR LONGER TURNAROUND. ENTIRE SEQUENCE NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF DISK RECORDING INHIBITED. 17-0001 +00M05S CPDR ACTIVATE BULK DISC RECORDING. PDR INFOTON KYBD #INRC,D RTN KEY-PRESS NOT PERFORMED ______ NOTE PERFORM SUBSTEPS 2 AND 3 AT HVAC ENGR DISCRETION. 17-0002 JBAC PERFORM FOLLOWING: 1. CLOSE MLP/PCR CHW BLOCKING HVAA VALVES JUST AFTER LIFTOFF. 2. OPEN CHW AUTO DRAIN VALVES FROM C-2 CONSOLE. NOT PERFORMED ______ SS2 3. SECURE REDUNDANT CHILLER IF NOT REQUIRED. NOT PERFORMED ______ SS3 17-0003 +00M07S JBPN CLOSE FACILITY GH2 LINE VALVE PNSA A3721 (C-1 CONSOLE CMD.) (M3020) SU72969 975 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0004 CHGD CURSOR CNTL (SAW01/HWW50) SU72928 POST LAUNCH SECURING XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY HGDS IN REMOTE SHUTDOWN 17-0005 CHGD BUHGDS REMOTE TERMINAL 1. MANUAL - 0 2. PROGRAM ZERO GAS - OFF BUHGDS SAFING PANEL - A 3. ON/STBY SWITCH - TOGGLE FOR STANDBY INDICATION BUHGDS SAFING PANEL - C 4. METER SELECT A - ZERO DVM | NOTE THE NEXT STEP REQUIRES 2 OC TCB'S FOR EXECUTION. THE STEP IS ARMED (YELLOW) AFTER GLS VERIFIES UMBILICAL DISCONNECT. 17-0006 +00M20S LPS CONSOLE KYBD CURSOR CNTL (AWP01 PG-B) TO I DA LDBA & UPLK TARGET - XMIT CURSOR KEY - PRESS 17-0007 +00M30S LPS ACTIVATE REDUNDANT SWITCH SU72930 ON GPCA, PLDA AND OIA FEPS. 17-0008 LPS AT LOCAL RCVS DISCONNECT PAD HARD LINE DATA FROM SOURCE 1 OF FEPS | AND CONNECT JSC OD DATA | (6TVM4096/1TVM4097/6TVM4648). | 976 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0009 JRPS DISCONNECT PAD HARDLINE DATA FROM | KMTS A (PRIMARY) AND CONNECT 192KB | JSC OD DATA (SKR) (6TVM4096/97/6TVM4648) | SWITCH KMTS A 0505A1 (A1,A2,A3) TO | SOURCE 2.C MANUAL MODE, SOURCE 2, | 60KB. | | 17-0010 LPS VERIFY JSC OD SIGNAL PRESENCE ON OIA/S, GPCA/S, PLDA/S FEP SCOPES, SOURCE 1. 17-0011 +00M30S CLDB TERMINATE RECORDING ON LDBM SUBSYSTEMS. NOTE PERFORM NEXT FOUR STEPS IN EVENT OF AN RTLS. 17-0012 LSO LRD RTLS HAS BEEN CALLED. STANDBY SU72927 LF1 FOR ORBITER LANDING AT KSC. NOT PERFORMED ______ 17-0013 LRD ATTENTION ALL PERSONNEL AN RTLS HAS 212 BEEN CALLED AND THE ORBITER IS RETURNING FOR A LANDING AT KSC. NOT PERFORMED ______ 17-0014 LRD NCC THIS IS AN RTLS ABORT. PREPARE CCN *DCD FOR AN ORBITER LANDING AT KSC ON 135 *MIL RUNWAY _____ (15 OR 33). SRO NET STM 205 ROC *SLF *SCC NOT PERFORMED ______ 17-0015 *SCC ALL MAINTAIN RADIO SILENCE ON NET NET 205. CONTACT *SCC ON NET 105. 205 MONITOR BOTH 105 AND 205 NETS. NOT PERFORMED ______ 977 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CCC SS AND FIREX TRANSFER ------------------------- VERIFICATION ------------ 17-0016 +00M44S JBWC VERIFY TRANSFER ACTION COMPLETE WSSA CRT (P2A OR P2B) SU72972 VERIFY INDICATOR STATE --------- ----- SS CCC ENABLE ON (GREEN) SS CCC - ON/FR - OFF ON (GREEN) SS FR ENABLE OFF (YELLOW) SS FR - ON/CCC - OFF OFF (YELLOW) 17-0017 +00M45S JBWC STOP PRINTER PLOTTERS WSSA CURSOR CNTL (LFA OR LFB) CURSOR TO 'C' OF 'PLOT CONTROL' XMIT CURSOR KEY - PRESS PFP 'PAD A' (NO.1) OR 'PAD B' (NO.2) KEY - PRESS 'TURN ON' KEY (NO.1) - PRESS CONSOLE KYBD EXEC CMD KEY - PRESS CRT (LFA OR LFB) VERIFY PLOT CONTROL OFF 17-0018 JBFX RECORD LAUNCH PAD WIND SPEED WSSA AND DIRECTION USING OTV SWITCHER INPUT SOURCE 189. SPEED __________ DIRECTION _________ 978 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LAUNCH PAD WASHDOWNS -------------------- 17-0019 +01M00S JBFX PERFORM LAUNCH PAD WASHDOWN WSSA ACCORDING TO FOLLOWING SEQUENCE SU72973 OF WATER FLOWS PER OMI M3190: NOTE SEQUENTIAL ORDER AND RUN TIMES FOR FOLLOWING SUBSTEPS ARE NOMINAL AND MAY BE ADJUSTED AS NECESSARY BY TEST TEAM TO MEET OPERATIONAL/AREA ACCESS CONSIDERATIONS. ONE PAD STRUCTURAL CYCLE (ALL SEQUENCES OF AUTOMATIC WASHDOWN SYSTEM) REQUIRES 12 MINUTES AT PAD A/9 MINUTES AT PAD B. DO NOT PERFORM ANY WASHDOWN WATER FLOW THAT HAS BEEN DETERMINED TO CAUSE AN ENVIRONMENTAL IMPACT. WINDSPEED AND DIRECTION, RAINFALL PRIOR TO LAUNCH AND GROUND WATER SATURATION WILL BE CONSIDERED. (REF FIGURE 10) 1. PAD STRUCTURE (NORMALLY SIX CYCLES) 2. LH2 STORAGE FACILITY (ONE FIVE MINUTE RUN) NOT PERFORMED ______ SS2 3. GH2 STORAGE FACILITY (ONE FIVE MINUTE RUN) NOT PERFORMED ______ SS3 979 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0020 LPS SWITCH GPCA, OIA AND PLDA FEPS SU72932 TO SOURCE 1, 192 KB JSC OD DATA VIA PROGRAM AWP01. 17-0021 LPS C1SE SWITCH VSB TO SOURCE 1 192 KB JSC OD DATA. SECURE HCU PUMPS ---------------- 17-0022 +01M00S CGSS CURSOR CNTL (VAJ14) SU72934 HCU PUMP 1 - OFF PUMP 2 - OFF UPLINK CARRIER HANDOVER ----------------------- NOTE MOMENTARY LOSS OF DOWNLIST/ DOWNLINK DATA WILL OCCUR DURING MILA TO PDL SWITCHOVER. 17-0023 +01M20S *MIL HANDOVER UPLINK CARRIER TO PDL. SU72936 NOTE PERFORM NEXT STEP IF PDL DATA AVAILABLE. 17-0024 *MIL SWITCH FM ME DATA (6TVM1729/6TVM4650) INPUT TO LCC FROM MILA DATA TO PDL DATA. (AFTER MILA VERIFICATION OF VALID PDL DATA) NOT PERFORMED ______ 980 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE AFTER NIGHT LAUNCHES, BROKEN STADIUM HALOGEN LAMP LENSES CAUSE FALSE FIRE DETECTOR INDICATIONS. PERFORM NEXT TWO STEPS AT TEST TEAM DIRECTION. 17-0025 CLHY TBC NUMEROUS FIRE INDICATIONS COMM 136 OCCURRING AT PAD. HAVE STADIUM TBC NTD LIGHTS SECURED TEMPORARILY. 232 REPORT COMPLETION. NTD STM STM JYVO 138 NOT PERFORMED ______ 17-0026 CLHY TBC ERRONEOUS FIRE INDICATIONS NOTED. COMM 136 STADIUM LIGHTS MAY BE REACTIVATED. TBC NTD REPORT WHEN COMPLETE. 232 NTD STM STM JYVO 138 NOT PERFORMED ______ 981 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0027 STM JSTC REPORT ALL FIRE ALARMS AND SMOKE SU72938 111 FIRE ALARMS RECEIVED ON 1P10 PANEL, JSTC JFIR LCC. REPORT COMPLETION. 114 | 17-0028 JFIR JSTC FOLLOWING FIRE ALARMS WERE FA 114 ACTIVATED BY LAUNCH: JSTC STM 111 ALARM NO. LOCATION STM NTD --------- -------- NTD *SCC _________ ________ 232 _________ ________ *SCC *PSE _________ ________ NET _________ ________ 105 SECURE GN2 PURGE SYS -------------------- 17-0029 OTC CPVD PERFORM "GN2 TO AIR CHANGE OVER- | 212 OPTION B - POST LAUNCH | OPERATIONS" PER OMI V1122. SU72974| COORDINATE WITH GSPN ON CH 172, SU72941| MAINTAIN PURGE TO PCR WITH SOUTH SU72951| BLOWER (RELEASE GSPN WHEN COMPLETE). RT OMI LOG NO.__________ 17-0030 STM JSTC GSPN COORDINATE CHANGEOVER PNU 111 WITH CPVD ON CH 172. SU72975 JSTC GSPN 114 17-0031 STM JTCR REPORT ACTUAL FIRST MOTION TIME 111 (TSM RELEASE). ___________________ (RECORD GMT) ___________________ (DAY/MO/YR) NOTE MOMENTARY LOSS OF DOWNLIST/ DOWNLINK DATA WILL OCCUR DURING PDL TO MILA SWITCHOVER. 17-0032 +02M30S *MIL RECEIVE UPLINK CARRIER HANDOVER SU72942 FROM PDL. 982 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0033 +03M00S JYVO STOP VIDEO RECORDINGS OF OTV COMM JYVR CAMERAS 003/103,005/105,034/134, SU72976 046/146,047/147,049/149,050/150, 051/151,052/152, 053/153 (LAUNCH CONFIGURATION). 17-0034 +03M00S JYVR STOP VIDEO RECORDING AS FOLLOWS: COMM 1. M-II RECORDERS CAMERA 001/101, 009/109, 041/141, 048/148, 051/151, 054/154, 055/155, 056/156, 060/160, 061/161, 063/163, 070/170, 071/171, TV-2, TV-4A/B, TV-5, TV-7A/B, TV-11, TV-13, TV-21A/B 2. S-VHS/VHS RECORDERS CAMERA 003/103, 011/111, 019/119, 030/130, 043/143, 049/149, 050/150, 072/172, STI-RSS ROOF, STI-C/S2 (ENGINEERING ANALYSIS) 983 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OTV SCAN - PAD/LAUNCH AREA -------------------------- NOTE OTV SCANS WILL TAKE APPROXIMATELY 16 MINUTES TO COMPLETE. 17-0035 +03M00S JYVO PROVIDE DEDICATED OTV SUPPORT COMM JYVR FOR *SCC OTV SCAN ASSESSMENT ON OIS CH 221 AS FOLLOWS. VIEW CAMERA ---- ------ 1. OVERVIEW OF PAD AREA FROM 001/101 NORTH TO EAST TO SOUTHWEST 2. OVERVIEW OF PAD AREA FROM 071/171 SOUTHWEST TO WEST TO NORTH. 3. PAD SURFACE, WEST SIDE 067/167 4. PAD SURFACE, EAST SIDE 060/160 5. MLP, SIDE 1 070/170 6. FSS AND RSS 060/160 7. MLP, ZERO LEVEL 009/109 SWITCH ABOVE CAMERAS TO MONITORS 023 AND 042 (FR-1) OR 183 AND 202 (FR-3). VIDEO RECORD INPUTS. 17-0036 +03M00S *SCC PERFORM OTV SCAN ASSESSMENT OF WSSA JBFX PAD/LAUNCH AREAS AND REPORT COMM JYVO ANOMALIES TO NTD ON OIS CH 232. SU72946 JBFX WILL INITIATE FIREX WATER IF REQUESTED BY NTD ON OIS CH 232 AND REPORT ACTION TO NTD. (SEE *SCC FIGURE 4) (CALL CTVO CONTROL ROOM (7-7810/7811) TO REQUEST PAN/TILT/ZOOM OF CTVO TV CAMERA TV-7A/B). 17-0037 +03M00S CLOX PERFORM OTV SCAN ASSESSMENT OF COMM CLHY PAD/LAUNCH AREAS ON OIS CH 138 JYVO AND REPORT ANOMALIES TO NTD. 984 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0038 +04M00S CBRS TBC SRB SRSS S AND A DEVICES IN SAFE SU72947 136 POSITION. TBC LRD 135 LRD BRD SRB AFT SKIRT GN2 PURGE TERMINATION ----------------------------------- 17-0039 TBC CBHY TERMINATE SRB AFT SKIRT GN2 SU72953 136 PURGE. CBHY COORDINATE WITH GSPN ON OIS CH 114. 17-0040 CBHY CURSOR CNTL (BAT04) SRB AFT SKIRT PURGE (HEATER) CMD - OF (VALVING) (MAIN) PRI - CL SEC - CL (VALVING) LOW PRI - CL SEC - CL DC PWR PRI - OF SEC - OF 17-0041 CBHY TBC SRB AFT SKIRT GN2 PURGE HAS BEEN 136 TERMINATED. TBC NTD 232 NTD *SCC NOTE DO NOT PERFORM NEXT THREE STEPS IF RTLS HAS BEEN DECLARED OR IF KSC IS DESIGNATED AOA LANDING SITE, UNTIL AOA OPTION HAS EXPIRED. 17-0042 +04M30S LSO LRD NEGATIVE RTLS. LF1 NOT PERFORMED ______ 985 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0043 +04M30S LRD NTD RTLS NO LONGER AN OPTION. JSTC 212 SRO PERSONNEL RELEASED TO SUPPORT COMM NTD *SCC PAD SAFING/INSPECTION OPERATIONS. SLF 212 STM ELEC *SCC *PSE SU72948 NET SU72925 | 105 STM FSTM 111 JSTC GYCC JSTC FSTC 114 JSEP NOT PERFORMED ______ 17-0044 LRD NCC RELEASE FROM RTLS/LANDING SUPPORT. CCN *DCD RECYCLE TO THREE HOUR READINESS 135 ROC STATUS. (S0028) EMS *SLF NOT PERFORMED ______ NOTE PRIOR TO PERFORMING NEXT STEP, CHECK WITH SLF CONTROL TOWER AND DETERMINE IF MSBLS SUPPORT TO CONTINUE FOR SHUTTLE TRAINING AIRCRAFT (STA). 17-0045 LRD STM KSC SLF NAVAIDS RELEASED FROM COMM 135 S0007 PLUS COUNT SUPPORT. STM GYCC SUPPORT KSC LANDING OPPORTUNITIES 111 PER S0028 AND MISSION UNIQUE ORBIT GYCC FTAC OPPORTUNITIES SCHEDULE. (MSBLS TO 117 FMLS REMAIN POWERED UP IF REQUIRED BY STA OR KSC IS PRIME AOA.) NOT PERFORMED ______ 986 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0046 *SCC *PSE EOD PERSONNEL MAY BE RELEASED NET AT THIS TIME. 105 NOTE DO NOT PERFORM NEXT STEP IF RTLS HAS BEEN DECLARED. 17-0047 *SCC ALL RADIO NET 205 NO LONGER REQUIRED NET FOR RTLS. 205 NOT PERFORMED ______ 17-0048 NTD CBSE CBSE PERSONNEL MAY BE RELEASED AT 232 THIS TIME. 17-0049 *SCC NTD SRM ACID CLOUD FORMATION ______ SU72949 232 (WILL/WILL NOT) AFFECT LC-39 NTD STM FACILITIES. NOTE PERFORM NEXT STEP AFTER ORBITER LANDING PER S0028 IF RTLS HAS BEEN DECLARED OR IF KSC IS DESIGNATED AOA LANDING SITE. 17-0050 STM GYCC UNPATCH 2RAC534 (126.65 MHZ WX COMM 111 BRIEFING) TO JSC ON NASCOM 2000 GYCC GYCJ CIRCUIT 3JKV63008. 117 NOT PERFORMED ______ 17-0051 NTD ALL ALL TEST TEAM PERSONNEL RETURN WSSA 212 TO YOUR NORMAL COMMAND AND PA OPERATING CHANNELS. JBFX CONTINUE TO MONITOR CH 232. 17-0052 STM JBAC SECURE COOLING TOWER HVAA 111 SPRAY SYSTEM. 987 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0053 +05M00S CLOX TBC LOX POST LAUNCH OPERATIONS PER 136 S1003 COMPLETE. PROCEEDING WITH LOX SYSTEM SAFING PER OMI G3153. 17-0054 CLOX TBC OTV SCAN OF LOX STORAGE AREA, CROSS 136 COUNTRY LINES, MLP AND FSS COMPLETE. TBC NTD REPORT STATUS. 232 LOX TANKING OMRS BUY-OFF TABLE ------------------------------ 17-0055 CLOX COMPLETION OF ET LOX TANKING FROM LOX/MPS PRELIMINARIES THROUGH T-10 SECONDS SATISFIES THE NOTED OMRS REQUIREMENTS. DETAILS OF LOX TANKING ARE SPECIFIED IN OMI S1003. OMRSD S00FB0.090-A-1 OMRSD S00FB0.300-1 OMRSD S00FB0.310-1 OMRSD S00FB0.320-1 OMRSD S00FB0.340-1 OMRSD S00FC0.080-1 OMRSD S00FC0.100-1 OMRSD S00FC0.120-1 OMRSD S00FD0.062-1 OMRSD S00FD0.073-1 OMRSD S00FD0.094-1 OMRSD S00FD0.095-A OMRSD S00FD0.121-A-1R OMRSD S00FF0.101-1 OMRSD S00FF0.145-1 OMRSD S00FM0.043-1 OMRSD S00FM0.050-1 OMRSD S00FM0.060-1 OMRSD S00FM0.321-1 OMRSD S00FM0.330 OMRSD S00FM0.342-1 OMRSD S00FM0.440-1 17-0056 CLOX TBC VERIFY 22D100, 23D100 AND BACKUP 136 BATTERY POWER SUPPLIES ARE TBC CPWR SUPPORTING. 17-0057 +05M00S NTD OTC BRIEF INSPECTION AND SAFING TEAMS 232 TBC ON HAZARDS THAT WILL BE PRESENT STM AND APPLICABLE SEQUENCES OF *SCC APPENDIX Z. 988 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING ALL PERSONNEL IN THE POST LAUNCH INSPECTION AND SAFING TEAMS SHALL WEAR THE FOLLOWING ACIDIC DEPOSIT PROTECTION GEAR AND SHALL NOT REMOVE WITHOUT THE CONCURRENCE OF SFOC SAFETY: 1. COVERALLS (BLUE COLLAR/ FLAME RETARDANT) 2. HARDHATS 3. A BREATHING ESCAPE UNIT (BEU) PACK SHALL BE CARRIED BY EACH MEMBER OF THE INSPECTION TEAM. BEU'S WILL BE WORN AS DIRECTED BY ENV HEALTH/SFOC SAFETY. 4. BEU'S SHALL BE WORN BY THE SAFING/SECURING TEAMS IF HYDROCHLORIC GAS IS DETECTED. IF AN AREA IS CONTAMINATED WITH HCL ONLY WORK REQUIRED TO SAFE AND SECURE AN AREA WILL BE PERFORMED. 5. RAINSUITS ARE AVAILABLE AT PAD GATE AND SHALL BE WORN IF REQUIRED FOR PAD ENTRY BY SFOC SAFETY. 17-0058 NTD *SCC VERIFY INSPECTION AND SAFING WSSA 232 OTC TEAMS READY TO PROCEED TO BDA TBC ROADBLOCK. STM *SCC *PSE NET 105 989 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0058 SAFETY INSPECTION TEAM CON'T ---------------------- (PLACARDS ONLY) --------------- SF (*PSE) 6 SFOC SAFETY 2 AT PAD GATE 4 INSP TEAM SF (NASA) 3 NASA SAF JBOSC 7 SECURITY 3 PAD GATE 4 BDA ROADBLOCKS VT 1 SITE MANAGER (AT PAD GATE) GSS 2 ELEC ENGR/TECH JBOSC 7 ENVIRONMENTAL HEALTH (2 AT PAD GATE, 5 INSP TEAM) ET 2 LO2/LH2 GSS 3 2 ENG/MECH(GO2/GH2&WATER) GSS 3 2 ENG/MECH(PNEU&WATER) JBOSC 9 FIRE/COMBAT (AT PAD GATE) ORB 1 PAD OPS ENGR (GSE) BLDG J8-2009 (PAD A ONLY) J7-0688 (PAD B ONLY) ORB 2 ENGR/TECH 990 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0058 INSPECTION TEAMS CON'T ---------------- NOTE INSPECTION TEAMS SHALL BE FORMED INTO 4 GROUPS AS INDICATED BELOW. TEAM ---- 1 - EAST PERIMETER - 1 (SFOC-SF) - 1 (EH) - 1 (ET LH2) - 2 (GSS) - 1 (FAC WATER) TEAM ---- 2 - WEST PERIMETER - 1 (SFOC-SF) - 1 (EH) TEAM ---- 3 - WEST PAD SURFACE/FSS - 1 (SFOC-SF) - 1 (FAC ELECT ENG) - 1 (EH) - 2 (GSS) - 1 (ORB) - 1 (FAC WATER) TEAM ---- 4 - EAST PAD SURFACE/RSS - 1 (SFOC-SF) - 2 (EH) - 1 (ORB) 991 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0058 SAFING TEAM CON'T ----------- ET (4+3) 7 LO2(INCLUDES 1 - *PSE) ET (7+6) 13 LH2(INCLUDES 3 - *PSE) GSS 4 GH2/GO2 SFOC-SF 1 GH2/GO2 GSS 1 GH2/GO2 EH 1 PTCR DEPRESS GSS 3 PTCR DEPRESS ORB 1 PTCR DEPRESS(ECS GN2 VALVES SFOC-SF 1 PTCR DEPRESS GSS 1 PTCR/MLP DEPRESS GSS 8 MLP DEPRESS (FLOOR PNL REPLACEMENT) SFOC-SF 1 MLP DEPRESS EH 1 MLP DEPRESS GSS 1* SITE MANAGER GSS 2* MOBILE SUPPLY (RAINSUITS, ETC) (*REMAIN OUTSIDE PAD GATE) JBOSC 1* L/S VAN (ELSA'S) (*REMAIN OUTSIDE PAD GATE) ET 7 ORDNANCE REMOVAL ORB 10 ORDNANCE REMOVAL GSS 16 HANDRAIL INSTALLATION GSS 5 (H/E) HANDRAIL TRANSPORT AND INSTALLATION GSS 1 HANDRAIL INSTALLATION GSS SLIDEWIRE SECURE (INCLUDED IN MLP DEPRESS) GSS 3 SPECIAL POWER TECHS AND ENGR TO RESET MLP ODMS GSS 2 LOW VOLTAGE ELECTRICIAN AND ENGR FOR ELECTRICAL SYSTEM SAFING JBOSC 2 RESET/SECURE PTCR/MLP FIRE ALARMS JBOSC 3 PAD GATE CONTINGENCY (SEC) JBOSC 4 ELECTRICAL SYSTEM SAFING 992 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0058 JBOSC 2 HCL MONITORS CON'T GSS 4 ELEV GSS 1 ELEV SFOC 1 (PSHL) GSE TECH 1 (PSHD) GSE TECH 1 (PSOM) GSE TECH 1 (PSOD) GSE TECH DEBRIS INSPECTION TEAM ---------------------- SFOC SAF 1 NASA KSC 3 NASA MSFC 1* NASA JSC 1* ORB 1* SRB 1* ET 2* SFOC 2 (* = OPTIONAL) NOTE DO NOT PERFORM NEXT STEP IF TAL LANDING DECLARED. 17-0059 +08M00S LRD *DCD BRAVO ALERT AIRCRAFT SUPPORTING RRT 135 DEPLOYMENT TO TAL SITE NO LONGER REQUIRED. NOT PERFORMED ______ 993 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF TAL LANDING DECLARED. 17-0060 LRD *DCD REQUEST BRAVO ALERT AIRCRAFT FOR RRT 135 DEPLOYMENT TO __________ (TAL SITE). NOT PERFORMED ______ 17-0061 +08M00S CGLS CONSOLE KYBD HOME CMD KEY - PRESS SET NUPONORBIT ON XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS 17-0062 CGLS CONSOLE KYBD HOME CMD KEY - PRESS SET N03IS080E OFF XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS 17-0063 +08M00S GYCC GYCJ REMOVE UMBILICAL A AND B PATCH COMM 117 TO THE PAD. VERIFY COMPLETION. SU72970 NOTE DO NOT PERFORM NEXT TWO STEPS IF: 1. RTLS HAS BEEN ANNOUNCED OR 2. KSC IS DESIGNATED PRIME AOA SITE. 17-0064 LRD NCC VERIFY READY FOR LOSS OF COMM ON CCN CONVOY COMMANDER, PURGE AND COOLING NETS. NOT PERFORMED ______ 994 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0065 +10M00S LRD STM DISABLE KSC TRANSMITTERS AND COMM 135 RECEIVERS ON CONVOY COMMANDER, STM GYCC PURGE AND COOLING NETS. 111 GYCC GYCJ 117 NOT PERFORMED ______ LANDING COMM CIRCUITS TO DFRC/WSSH ---------------------------------- NOTE DO NOT PERFORM NEXT SEVEN STEPS IF RTLS OCCURRED OR A DECISION HAS BEEN ANNOUNCED FOR A TAL. PERFORM NEXT STEP IF: 1. ALTERNATE LANDING SITE CONVOY COMMANDER NET IS ACTIVATED, AND 2. EITHER DFRC OR WSSH IS DESIGNATED PRIME AOA LANDING SITE FOR THIS MISSION. 17-0066 LRD STM RECONFIGURE ALTERNATE LANDING COMM 135 SITE CONVOY COMMANDER NET FROM ______ STM GYCC (DFRC/WSSH) TO KSC. 111 GYCC GYCJ 117 NOT PERFORMED ______ 995 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS IF DFRC IS DESIGNATED PRIME AOA LANDING SITE FOR THIS MISSION. 17-0067 +10M00S LRD STM ACTIVATE FOLLOWING: COMM 135 STM GYCC 1. DFRC SPA 3/COOLING NET 111 T/R TO KSC COOLING NET. GYCC GYCJ 117 2. DFRC SPA 4/CONVOY COMMANDER NET. T/R TO KSC CONVOY COMMANDER NET. 3. DFRC SPA 6/PURGE NET T/R TO KSC PURGE NET. VERIFY FOLLOWING: 1. DFRC SPA 1 T/R TO OIS CH 135 2. DFRC SPA 8 T/R TO OIS CH 161 NOT PERFORMED ______ 17-0068 GYCC GYCJ PERFORM VOICE CHECKS ON OIS COMM 117 CHANNELS AND RADIO NETS, CONFIGURED FOR DFRC LANDING. NOT PERFORMED ______ 17-0069 GYCJ GYCC COMM CIRCUITS CONFIGURED AND COMM 117 VOICE CHECKED FOR DFRC LANDING. GYCC STM 111 STM LRD 135 NOT PERFORMED ______ 996 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS IF WSSH IS DESIGNATED PRIME AOA LANDING SITE FOR THIS MISSION. 17-0070 +10M00S LRD STM ACTIVATE WSSH OIS-A4 CONVOY COMM 135 COMMANDER NET T/R TO KSC CONVOY STM GYCC COMMANDER NET. 111 GYCC GYCJ 117 NOT PERFORMED ______ 17-0071 GYCC GYCJ PERFORM VOICE CHECKS ON COMM COMM 117 CIRCUITS, CONFIGURED FOR WSSH LANDING. NOT PERFORMED ______ 17-0072 GYCJ GYCC COMM CIRCUITS CONFIGURED AND COMM 117 VOICE CHECKED FOR WSSH LANDING. GYCC STM 111 STM LRD 135 NOT PERFORMED ______ 997 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE *SCC WILL DETERMINE IF ACID CLOUD IS PROJECTED TO IMPACT NON-LAUNCH PAD. 17-0073 NTD *SCC ASSESS IF SRM ACID CLOUD IS SU72924 232 PROJECTED TO IMPACT NON-LAUNCH *SCC *PSE PAD. NET 105 17-0074 *SCC NTD SRM ACID CLOUD __________ (IS/ SU72961 232 IS NOT) PROJECTED TO IMPACT NON-LAUNCH PAD. INSP & SAFING TEAMS TO PAD GATE ------------------------------- 17-0075 +10M00S NTD *SEC ALLOW INSPECTION AND SAFING SEC 232 TEAM CONVOY TO PROCEED THRU LDA ROADBLOCK AB-11. 17-0076 NTD STM SEND TWO FIRE COMBAT TEAMS FROM FIRE 232 AB-11 TO LAUNCH PAD ___ GATE WITH STM JSTC SAFETY ESCORTED CONVOY. ESTABLISH 111 BASE JUST INSIDE PAD GATE AND JSTC JFIR PERFORM COMM CHECK WITH NTD AND 114 *PSE ON NET 105. STANDBY TO SUPPORT PAD ENTRY OPERATIONS. 998 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OPTION 1 -------- NOTE PERFORM NEXT FOUR STEPS IF SRM ACID CLOUD IS NOT PROJECTED TO IMPACT NON-LAUNCH PAD. 17-0077 +10M00S NTD OTC INSPECTION AND SAFING TEAMS SU72926 232 TBC PROCEED TO LAUNCH PAD BDA SU72929 STM ROADBLOCK A-5 (PAD A) OR A/B-4 *SCC (PAD-B) WITH SAFETY ESCORTED *SCC *PSE CONVOY. SFOC SAFETY AND NET ENVIRONMENTAL HEALTH PROCEED TO 105 PAD GATE AND PERFORM ACID AND HYPER TVC'S. NOT PERFORMED ______ 17-0078 *PSE *SCC PAD GATE ACID AND HYPER TVC'S SU72931 NET COMPLETE AND IS:__________________ 105 *SCC NTD __________________________________ 232 NOT PERFORMED ______ 17-0079 NTD *SCC INSPECTION AND SAFING TEAMS SEC 232 *SEC PROCEED TO PAD GATE AND PREPARE SU72933 *SCC *PSE FOR PAD SECURING. NET 105 NOT PERFORMED ______ 17-0080 *PSE *SCC INSPECTION AND SAFING TEAMS ON NET SITE AT PAD GATE. 105 *SCC NTD 232 NOT PERFORMED ______ 999 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OPTION 2 -------- NOTE PERFORM NEXT SEVEN STEPS IF SRM ACID CLOUD IS PROJECTED TO IMPACT NON-LAUNCH PAD. INSPECTION AND SAFING TEAM CONVOY WILL INCLUDE SAFETY AND SECURITY VEHICLES TO SUPPORT ENVIRONMENTAL ASSESSMENT AT THE NON-LAUNCH PAD. THESE VEHICLES WILL SPLIT FROM THE CONVOY AT THE A-5 ROADBLOCK AND PROCEED TO THE NON-LAUNCH PAD. SFOC SAFETY AND ENVIRONMENTAL HEALTH WILL PERFORM TVC'S AT BOTH THE LAUNCH AND NON-LAUNCH PADS IN PARALLEL. 17-0081 +10M00S NTD OTC INSPECTION AND SAFING TEAMS SU72963 232 TBC PROCEED TO LAUNCH PAD BDA SU72965 STM ROADBLOCK A-5 (PAD A) OR A/B-4 SU72960 | *SCC (PAD B) WITH SAFETY ESCORTED *SCC *PSE CONVOY. SFOC SAFETY AND NET ENVIRONMENTAL HEALTH WILL 105 PROCEED TO PAD A AND B GATES AND PERFORM ACID AND HYPER TVC'S. NOT PERFORMED ______ 17-0082 *PSE *SCC LAUNCH PAD GATE ACID AND HYPER TVC'S NET COMPLETE AND IS:___________________ 105 *SCC NTD ___________________________________ 232 NOT PERFORMED ______ 17-0083 NTD *SCC INSPECTION AND SAFING TEAMS SEC 232 *SEC PROCEED TO PAD GATE AND PREPARE *SCC *PSE FOR PAD SECURING. NET 105 NOT PERFORMED ______ 1000 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0084 *PSE *SCC INSPECTION AND SAFING TEAMS ON SEC NET SITE AT PAD GATE. SU72966 105 *SCC NTD 232 NTD *SEC NOT PERFORMED ______ 17-0085 JBFX RECORD NON-LAUNCH PAD WIND WSSA SPEED AND DIRECTIONS USING OTV SWITCHER INPUT SOURCE 189. SPEED __________ DIRECTION ___________ NOT PERFORMED ______ NOTE DO NOT PERFORM ANY WASHDOWN WATER FLOW THAT HAS BEEN DETERMINED TO CAUSE AN ENVIRONMENTAL IMPACT. WINDSPEED AND DIRECTION, RAINFALL PRIOR TO LAUNCH AND GROUND WATER SATURATION WILL BE CONSIDERED. (REF FIGURE 10) 17-0086 NTD STM PROCEED WITH FOLLOWING NON FIRE 232 LAUNCH PAD STORAGE AREA WSSA STM JBFX WASHDOWNS PER OMI M3190. SU72962 111 JSTC JSTC JFIR 114 1. LH2 AREA NOT PERFORMED ______ SS1 2. GH2 AREA NOT PERFORMED ______ SS2 NOT PERFORMED ______ 1001 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0087 *PSE *SCC NON-LAUNCH PAD ACID AND HYPER SU72967 NET TVC'S ARE COMPLETE AND IS:______ SU72965 105 *SCC NTD __________________________________ 232 NOT PERFORMED ______ 17-0088 *SCC NTD RELEASE PAD RESCUE (ARMORED FIRE 232 VEHICLE) TEAM AT A-5 OR A/B-4 SU72977 NTD STM R/B AFTER INSPECTION AND SAFING STM JSTC TEAM HAS PASSED APPROPRIATE R/B. 111 JSTC JFIR 114 NOTE DO NOT PERFORM NEXT STEP IF RTLS DECLARED. 17-0089 +10M30S LPS CPDR FORCE PDR TAPE SWITCH 127 AT PDR INFOTON #INRC T(X) RTN KEY - PRESS NOT PERFORMED ______ 17-0090 LPS CPDR PERFORM $$SPOOL RESET ASSIGN RP. 17-0091 +15M00S SRO NTD POST LAUNCH INDICATES NO 232 APPARENT LAUNCH IMPACT LIMIT LINE ANOMALIES. 1002 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FLIGHT CONTROL P/P DEACTIVATION ------------------------------- 17-0092 +15M00S COFC APPL PG (SWB01 PG A) PFK 12 KEY - PRESS (ACT P/P SETUP) 17-0093 COFC CURSOR CNTL (SWB01 PG A) (ON ITEMS BELOW) XMIT CURSOR KEY - PRESS 1. I-ENG POSN - SUB SYS=2, ODV=3 2. I-AERO POSN - SUB SYS=2, ODV=4 17-0094 COFC APPL PG (SWB01 PG A) PFK 12 KEY - PRESS (DE-ACT P/P SETUP) 17-0095 COFC OTC P/P DEACTIVATION COMPLETE. 132 READY FOR REMOVAL FOR DATA OTC LPS COORDINATOR PICKUP. LPS C2MC (PP2 UNITS 3 AND 4) 127 GNC/EFC LCD EMON DEACTIVATION ----------------------------- 17-0096 COFC APPL PG (SWB01 PG A) PFK 13 KEY PRESS (ACT EMON SETUP) 17-0097 COFC CURSOR CNTL (SWB01 PG A) (ON ITEMS BELOW) XMIT CURSOR KEY - PRESS 1. I - IMU PWR UP 2. I - IMU OPERATE 3. I - OMS TVC 4. I - SRB TVC 5. I - RJD DRIVER 6. I - SRB RGA 7. I - CIRC PUMPS 8. I - NON PREREQUISITE 17-0098 COFC APPL PG (SWB01 PG A) PFK 13 KEY - PRESS (DE-ACT EMON SETUP) 1003 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0099 CLHY TBC OTV SCAN OF LH2 STORAGE AREA, CROSS 136 COUNTRY LINES, MLP AND FSS COMPLETE. TBC NTD REPORT STATUS. 232 17-0100 +19M00S *SCC NTD OTV SCAN OF PAD AND LAUNCH AREAS 232 VERIFIED COMPLETE. REPORT STATUS. *SCC *PSE NET 105 17-0101 +19M00S NTD STM OTV SCAN OF PAD AND LAUNCH AREAS COMM 232 COMPLETE. STOP VIDEO RECORDING WSSA STM JYVO OF INPUTS TO OTV MONITORS 023 AND 138 JYVR 042 (LCC-1) OR 183 AND 202 (LCC-3). 111 JBFX 17-0102 JCFM STOP PMS RECORDERS EXCEPT FOR METEOROLOGICAL DATA RECORDER. RECORD MET DATA TILL T+30 MINUTES. ACTIVATE PAD OIS ---------------- 17-0103 STM GYCC ACTIVATE OIS-D TO PAD____. COMM 111 SU72978 GYCC JYCD 117 17-0104 GYCC STM PAD ____ OIS-D ACTIVATED. COMM 111 STM NTD 232 1004 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE | | PERFORM NEXT STEP FOR IUS | MISSION (STS-93). | | IUS GSE SECURING | ---------------- | | 17-0105 PTC ICTC PERFORM POST LAUNCH SECURING PER | 134 DOP D290-50020-27. REPORT COMPLETION. | | NOT PERFORMED ______| PAYLOAD CONSOLE SOFTWARE TERMINATION ------------------------------------ NOTE PERFORM NEXT THREE STEPS IF PAYLOAD CONSOLE SOFTWARE TERMINATION IS REQUIRED. 17-0106 PTC DLES TERMINATE GOAL PROGRAMS THAT WERE DLES DCOI REQUIRED TO SUPPORT TESTING. 144 NOT PERFORMED ______ 17-0107 DLES DCOI C1 CONSOLE TERMINATE ALL DMONS NOT PERFORMED ______ 17-0108 DCOI DLES PAYLOAD CONSOLE SOFTWARE TERMINATION DLES PTC COMPLETE. NOT PERFORMED ______ 1005 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE BDA ROADBLOCKS SHALL BE ESTABLISHED AFTER COMPLETION OF ACID AND HYPER TVC'S AT APPLICABLE PAD(S). ESTABLISH BDA ROADBLOCKS ------------------------ 17-0109 NTD *SEC ESTABLISH BDA ROADBLOCKS A-1, SEC 232 B-1, A-3, A/B-4, A-5, A-6 SU72935 (PAD A LAUNCH)/A-1, B-1, B-3, SU72981 A/B-4, (PAD B LAUNCH). DROP SU72966 ROADBLOCKS A/B-11 AND A/B-15 WHEN BDA ROADBLOCKS ESTABLISHED. OPEN AREAS OUTSIDE BDA FOR NORMAL WORK. 17-0110 NTD STM PERSONNEL SUPPORTING SUPPORT 232 LPS OPERATION SUPPORT SETUP 3 - STM JSTC FALLBACK CONFIGURATION - SUPPORT 111 GYCC RED CREW ARE RELEASED. JSTC JSEP ELEC JSAC AC GSPN PNU GSPS PN GSFA FA JSWC WW *SCB LS *SEC SEC WCRG RGR GYCC JYCJ COMM 117 PTP JYVO EPDC POST LAUNCH SECURING ------------------------- 17-0111 OTC CEPD PERFORM POST LAUNCH SECURING 132 PER S0007VL4 (SEQ 59). 1006 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GROUND PIC TEST RESULTS ----------------------- NOTE NEXT STEP VERIFIES THE FOLLOWING: T-0 COMMAND IS RESET ALL GROUND PIC CAP VOLTAGES ARE LESS THAN 1.5 VDC. GROUND PIC RACKS ARE POWERED DOWN. LISTS RESULTS OF RESISTANCE TESTS (GO INDICATIONS). 17-0112 CEPD OTC GROUND PIC RESISTANCE TEST SU72937 132 (VL4 SEQ 59) FOR ETVAS, TSM SU72954 OTC NTD AND H2 BURN VERIFIED COMPLETE 232 AND RESULTS ARE AS FOLLOWS NTD *SCC (RECORD ANY RESISTANCE TEST "G" TBC INDICATIONS FROM SEQ 59): _________________________________ _________________________________ _________________________________ 17-0113 CEPD OTC POST LAUNCH SECURING (SEQ 59 - SU72955 132 GROUIND POWER SHUTDOWN) COMPLETE. OTC NTD 232 NTD *SCC 1007 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ENABLE EXTERNAL PAGING TO CONTROL --------------------------------- ROOMS ----- 17-0114 +20M00S NTD STM ENABLE EXTERNAL PAGING TO ACTIVE COMM 232 AND BACKUP CONTROL ROOMS FOR S0007. STM GYCC REPORT COMPLETION. 111 GYCC JYCJ 117 VERIFY PERSONNEL STATUS ----------------------- 17-0115 *SEC NTD BDA ROADBLOCKS ESTABLISHED. SU72982 232 LDA ROADBLOCKS DROPPED. AREAS SU72983 OUTSIDE BDA OPEN FOR CONTROLLED SU72980 | WORK. 17-0116 +22M00S *SCC NTD VERIFY STATUS OF ALL PERSONNEL JSTC 232 LOCATED WITHIN IMPACT LIMIT COMM NTD STM LINES/LAUNCH DANGER AREA. SU72939 STM JPHO 111 JSTC GYCC GYCC WYVF PTP 17-0117 JPHO STM PHOTO PERSONNEL WITHIN LAUNCH 111 DANGER AREA ARE ALL SAFE. STM NTD 232 17-0118 JSTC STM ALL J-BOSC PERSONNEL WITHIN JSTC 111 LAUNCH DANGER AREA ARE SAFE. STM NTD 232 17-0119 WYVF GYCC TELEVISION CAMERA OPERATORS COMM PTP WITHIN LAUNCH DANGER AREA ARE GYCC STM SAFE. 111 STM NTD 232 1008 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0120 +22M00S NTD *SCC ALL PERSONNEL LOCATED WITHIN IMPACT 232 LIMIT LINES/LAUNCH DANGER AREA ARE SAFE. 17-0121 NTD SRO SRO MAY BE RELEASED AT THIS TIME. 232 STATUS SENSOR SYSTEMS --------------------- 17-0122 +22M00S *SCC NTD STATUS LH2 LEAK AND FIRE SENSORS. SU72940 232 (MPS) (GH2 FACILITY). NTD OTC STM TBC 17-0123 STM JBPN STATUS GH2 FACILITY LEAK AND PNSA 111 FIRE SENSORS. (SKELETON H2A FOR PAD A, H2B FOR PAD B) 17-0124 OTC CMPS REPORT STATUS OF LH2 LEAK AND FIRE DETECTORS. 17-0125 TBC CLHY REPORT STATUS OF LH2 LEAK AND 136 FIRE DETECTORS (LH2). NOTE NUMEROUS FIRE INDICATIONS FOLLOWING A LAUNCH WITH STADIUM LIGHTS ON COULD BE RESULT OF BROKEN UV FILTERS. THIS CAN BE VERIFIED BY STM CYCLING THE STADIUM LIGHTS OFF, THEN ON. 17-0126 JBPN STM GH2 FACILITY LEAK AND FIRE PNSA 111 DETECTORS SHOW NO PROBLEM (OR STM NTD STATE ACTUAL STATUS). 232 17-0127 +22M00S OTC NTD MPS LEAK AND FIRE DETECTORS SHOW 232 NO PROBLEM (OR ACTUAL STATUS). 1009 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0128 CLHY TBC LH2 LEAK AND FIRE DETECTORS SHOW 136 NO PROBLEM (OR ACTUAL STATUS). TBC NTD 232 17-0129 NTD *SCC LEAK AND FIRE DETECTOR 232 STATUS CHECKS COMPLETE - *SCC *PSE NO ANOMALIES NOTED (OR NET ACTUAL STATUS). 105 POWER DOWN ASTRO COMM --------------------- 17-0130 +23M00S OTC ASTRO COMM - OIS PANEL 1. ALL SWITCHES-OFF 2. POWER SW-OFF OAA/HCU FIRING ROOM SECURING ---------------------------- 17-0131 CGSS OTC ORB OPERATION SUPPORT SETUP 18 - 132 SOUND SUPPRESSION/EMERGENCY EGRESS FLAME DETECTION MONITOR COMPLETE. 17-0132 OTC CGSS PERFORM OAA AND HCU FIRING ROOM 132 SECURING PER OMI V2153 AND OMI V2160. 17-0133 CGSS OTC OAA AND HCU FIRING ROOM SECURING 132 COMPLETE. 1010 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ET MECHANICAL SECURING ---------------------- CAUTION LOSS OF 28 VDC POWER (23D100 BUS) WILL CAUSE GVA TO UNLATCH AND EXTEND. NOTE PROGRAMS WILL BE REPERFORMED AND GVA POST LAUNCH SECURING ACCOMPLISHED PER S2005. 17-0134 TBC CMEC PERFORM POST LAUNCH PROGRAM SU72956 136 TERMINATION PER OMI G2158. 17-0135 CMEC TBC POST LAUNCH PROGRAM TERMINATION 136 COMPLETE. 1011 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RANGE SAFETY TEST CODE LOAD --------------------------- 17-0136 +25M00S TBC CBRS PERFORM RANGE SAFETY TEST CODE SU72957 136 LOAD PER OMI S5018. 17-0137 TBC CBRS PERFORM SRSS MLP GSE POWER DOWN. SU72958 136 17-0138 CBRS CURSOR CNTL (SWRB3) BSR01 - XMIT CURSOR POWER OFF SYSTEM A&B - XMIT CURSOR 17-0139 CBRS CURSOR CNTL (BWR10) HOLDFIRE EMON INH XMIT CURSOR KEY - PRESS 17-0140 CBRS CURSOR CNTL (SWRB3) BSR01 XMIT CURSOR KEY - PRESS POWER ON SYS A&B A PRIME XMIT CURSOR KEY - PRESS 17-0141 CBRS CURSOR CNTL (SWRB3) BSR01 XMIT CURSOR KEY PRESS POWER OFF SYSTEM A&B XMIT CURSOR KEY - PRESS 17-0142 CBRS CURSOR CNTL (SWRB2) DCDR IND I XMIT CURSOR KEY - PRESS AGC VOLT I XMIT CURSOR KEY - PRESS 17-0143 CBRS CURSOR CNTL (SWRB1) EMON INH XMIT CURSOR KEY - PRESS 17-0144 CBRS TBC SRSS GSE POWER DOWN COMPLETE. 136 1012 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0145 CTIF TBC GO2 VENT HOOD AND ET TPS ICE/FROST 136 AND DEBRIS MONITORING COMPLETE (S6444). OMRSD S00FB0.005-1 OMRSD S00FB0.350-1 OMRSD S00FB0.360-1 LO2/LH2 TRANSFER LINE PURGE - ----------------------------- INITIATED --------- 17-0146 +25M00S CLOX TBC LOX TRANSFER LINE PURGE HAS BEEN 136 INITIATED. 17-0147 CLHY TBC LH2 TRANSFER LINE PURGE HAS BEEN 136 INITIATED. 17-0148 TBC NTD LOX AND LH2 TRANSFER LINE PURGES SU72952 | 232 HAVE BEEN INITIATED. NTD *SCC *SCC *PSE NET 105 GN2 TO AIR CHANGEOVER COMPLETE ------------------------------ 17-0149 CPVD OTC GN2 TO AIR CHANGEOVER OPTION B - SU72943 132 POST LAUNCH OPERATIONS COMPLETE. OTC NTD AWAITING ECS PERSONNEL TO ENTER 232 ECS ROOM. NTD *SCC *SCC *PSE NET 105 1013 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- VERIFY READY FOR PAD INSPECTION ------------------------------- 17-0150 +25M00S *PSE *SCC INSPECTION AND SAFING TEAMS SU72933 NET AT PAD GATE. 105 *SCC NTD 232 17-0151 +25M00S NTD STM START VIDEO TRACKING AND VIDEO COMM 232 RECORD SAFETY INSPECTION STM JYVO WALKDOWN TEAM. POSITION OTV 138 JYVR CAMERAS IN SEQUENCE, TO TRACK EAST SIDE INSPECTION TEAM. POSITION OTV CAMERAS IN SEQUENCE, TO TRACK WEST SIDE INSPECTION TEAM. 17-0152 +25M00S *SCC NTD VERIFY FOLLOWING ITEMS BEFORE SU72992 232 PROCEEDING WITH INSPECTION 1. OTV SCAN OF PAD AREAS COMPLETE. (REF STEP NO.__________) 2. GROUND PIC RESISTANCE TEST COMPLETED AND GND PIC RACKS POWERED DOWN. (REF STEP NO.__________) 3. FIRE/LK DETECTOR STATUS CKS COMPLETE. (REF STEP NO.__________) 4. LO2 RESIDUAL PURGING AND 30 MINUTE LH2 XFER LINE PURGES - INITIATED. (REF STEP NO.__________) 5. GN2 TO AIR CHANGEOVER COMPLETE. (REF STEP NO.__________) 1014 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0153 NTD *SCC THE FIVE ITEMS LISTED IN PREVIOUS 232 STEP HAVE BEEN COMPLETED. PROCEED *SCC *PSE WITH PAD INSPECTION. NET 105 LAUNCH PAD LH2/GH2 WASHDOWN --------------------------- OPERATIONS COMPLETE ------------------- NOTE PERFORM NEXT STEP IF LAUNCH PAD WASHDOWNS WERE REQUIRED. 17-0154 JBFX STM LAUNCH PAD LH2/GH2 STORAGE WSSA 111 AREAS WASHDOWN FLOWS COMPLETE. SU72A42 STM NTD 232 NTD *SCC *SCC *PSE 221 NOT PERFORMED ______ 17-0155 NTD LPS INHIBIT PROCESSING FOR FDS V67V0100A1 232 AND V67V0200A1, AND KEEP THEM INHIBITED FOR DURATION OF MISSION. (I PR V67V0_00A1) 1015 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PAD INSPECTION TEAM FUNCTIONS ----------------------------- NOTE SAFING TEAMS WILL REMAIN AT PAD GATE UNTIL PERIMETER INSPECTION TEAM HAS COMPLETED THEIR INSPECTION. LOX AND LH2 STORAGE AREA FIRE AND SECURITY SUPPORT REMAIN AT PAD GATE UNTIL PERIMETER INITIAL INSPECTION IS COMPLETE, AND THEN PROCEED TO APPLICABLE STORAGE FACILITY BEHIND THE SAFING TEAM. 17-0156 +25M00S NTD *SCC PERFORM PAD PERIMETER AND SU72993 232 SURFACE INSPECTION TEAM SU72998 *SCC *PSE FUNCTIONS AS SPECIFIED BELOW: SU72A04 NET 105 1. PERIMETER ROAD AREAS A. DIVIDE INSPECTION TEAM INTO 2 GROUPS. B. INSPECT EAST AND WEST SIDES IN PARALLEL. 2. EAST SIDE FACILITIES A. HYPER OXIDIZER STORAGE AREA (TOXIC VAPOR CHECKS) B. HI PRESSURE STORAGE AREA (GO2 CHECKS AND SECURING OF FIREX VALVE V-64). C. LH2 STORAGE AREA (EXPLOSIVE LEAK CHECKS) D. GH2 STORAGE AREA (EXPLOSIVE LEAK CHECKS) 1016 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0156 3. WEST SIDE FACILITIES CON'T A. HYPER FUEL STORAGE AREA (TOXIC VAPOR CHECKS) B. LO2 STORAGE AREA (O2 VISUAL LEAK CHECKS) C. ELECTRICAL SUB-STATION (VISUAL INSPECTION) D. PAD TUNNEL AREA (VERIFY/HANG SIGN) E. PTCR/ECS ROOM/BOX CAR CITY 4. PAD SURFACE AREAS A. EAST AND WEST SIDES OF FLAME TRENCH B. MLP SIDE 1 INSPECTION (INSPECTION WILL BE PERFORMED FROM PAD SURFACE) VISUAL. C. POST ROPES/SIGNS TO CLOSE OFF "E" ROAD NORTH OF PAD SURFACE 17-0157 +25M00S TBC CPWR PERFORM ET HTR SECURING. SU72959 136 17-0158 CPWR PFP (TW495) ET HTR MOD PWR - PRESS HEATER MOD OFF - PRESS CRT (TD490) VERIFY HTR PRI DC MODULE OFF HTR SEC DC MODULE OFF 1017 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0159 +25M00S CPWR CONSOLE KYBD (TW495) PFK 15 KEY - PRESS NOTE PERFORM NEXT STEP ONLY IF LED 3 READS "AUTO ET OPS ACT". 17-0160 CPWR PFP (BWE08) PFPK3 KEY - PRESS VERIFY LED 3 - AUTO ET OPS INH NOT PERFORMED ______ 17-0161 +25M00S CPWR CONSOLE KYBD (BWE08) PFK 15 KEY - PRESS 17-0162 +25M00S CPWR CONSOLE KYBD (BWE11) PFK 15 KEY - PRESS NOTE PERFORM NEXT STEP IF BWE11 DID NOT TERMINATE IN PREVIOUS STEP DUE TO HTRS BEING ACTIVE. 17-0163 CPWR CONSOLE KYBD (BWE11) PFK 15 KEY - PRESS NOT PERFORMED ______ 17-0164 CPWR TBC ET HTR SECURING COMPLETE. 136 17-0165 CBRS TBC RANGE SAFETY TEST CODE LOAD PER 136 S5018 COMPLETE. 1018 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0166 CGLS CURSOR CNTL PSEUDO INIT XMIT CURSOR ALL PSEUDOS AND DISK FILES XMIT CURSOR NOTE IF PAGE B MSG INDICATES: "SEE PAGE A FOR OPERATOR INPUT" PERFORM THE NEXT TWO STEPS. 17-0167 CGLS CRT VERIFY PAGE A MSG: (N03IS511E) CRYO SAFING ENABLED IS ON. THIS INDICATES SCRUB/CRYO DRAIN IN PROGRESS. NOT PERFORMED ______ 17-0168 CGLS CONSOLE KYBD (SLP02 PAGE A) ENTER "1" IF CRYO SAFING SUPPORT COMPLETED AND SLP50 NOT ACTIVE TO INITIALIZE (N03IS511E) TO OFF. ENTER "2" TO LEAVE (N03IS511E) UNCHANGED ____ (1 OR 2) XMIT RESPONSE KEY - PRESS CRT VERIFY MSG INDICATING PSEUDO STATE NOT PERFORMED ______ 17-0169 CGLS VFY ALL BLOCKS CYAN TERMINATE XMIT CURSOR 1019 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF SA001 IS ACTIVE. 17-0170 CGLS LPS PFP (SA001) 127 PFPK6 KEY - PRESS (TERMINATE SA001) PFPK5 KEY - PRESS (TERMINATE EXECUTE) CRT VERIFY PROGRAM SA001 HAS TERMINATED NOT PERFORMED ______ 17-0171 CGLS LPS PFP (SLP50) PFPK1 KEY - PRESS (TERMINATE) PFPK6 KEY - PRESS (EXEC TERM PROGRAM) VERIFY PROGRAM SLP50 HAS TERMINATED 17-0172 CGLS INTERGRATION SAFING PANEL ENABLE SW - OFF 17-0173 CGLS TERM GLS SOFTWARE. SSME GSE SECURING ----------------- 17-0174 CSME CURSOR CNTL (VAE38A PG-B) SU72944 MFV HTR DISPLAY ALL HTR OFF - ISSUE VERIFY ALL CMDS REMOVED 1020 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0175 CSME CURSOR CNTL (VAE38A PG-B) GN2 DISPLAY PRI VENT OPEN CMD - OFF SEC VENT OPEN CMD - OFF CONT VALVE PRI CLOSE CMD - OFF CONT VALVE SEC CLOSE CMD - OFF PRI REG OUT CLOSE CMD - OFF SEC REG OUT CLOSE CMD - OFF VERIFY STABLE PRESSURE CONT VALVE PRI CLOSE CMD - ON VERIFY GN2 OUTLET PRESSURE DOES NOT INDICATE EXCESSIVE LEAKAGE THROUGH T-0 QD PORT PRI CONT VALVE - OPEN CMD OFF AC PRI CMD - OFF DECREMENT SEC HTR CMD TO MINIMUM 17-0176 CSME PFP (VAE38) PFP6 (TERMINATE) KEY - PRESS 1021 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MPS S72-0685-1 SAFING (LPS) --------------------------- 17-0177 CMPS CURSOR CNTL (VAE18) SU72945 1. A74935/A74937 PRIMARY/SECONDARY REG SOV OPEN CMD OVERRIDES - OFF 2. VERIFY A74937/A74937 PRIMARY/ SECONDARY REG SOV'S REMAIN CLOSED. 3. A74936 PRIMARY/SECONDARY GHE SOV CLOSE COMMANDS - OFF 4. VERIFY A74936 GHE SOV OPENS. 5. VERIFY 4500 PANEL OUT PRESSURE INDICATES AMBIENT. 6. A74989/A75026 PRIMARY/SECONDARY LINE VENT OPEN COMMANDS - OFF 7. VERIFY A74989/A75026 PRIMARY/ SECONDARY LINE VENTS CLOSE 8. VERIFY A74933/A74939 PRIMARY/ SECONDARY REG VENTS ARE CLOSED. 17-0178 CMPS CONSOLE KYBD (C4) VAE35 PERF PGM KEY - PRESS 2 XMIT RESP KEY - PRESS CRT VERIFY VAE35 TERMINATES WITH NO ERROR MESSAGE 1022 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WIRE FRAME ACCESS CONFIGURATION ------------------------------- 17-0179 +30M00S GYCC PERFORM FOLLOWING: 1. IF RTLS, TAL OR AOA HAS NOT COMM BEEN ANNOUNCED, WIRE FRAMES LISTED BELOW ARE TO BE CHANGED FROM "CLOSED ACCESS" TO "CONTROLLED ACCESS" FOR DURATION OF ORBITAL FLIGHT. A. USB (MILA) B. BRRS C. CDSC - FRAMES 1, 40 AND WT D. LACB - FRAMES 66 AND 74 E. VABR F. TEL 4 G. SO REP LCC FRAMES MAY BE OPENED FOR NORMAL WORK. NOT PERFORMED ______ SS1 2. IF RTLS OR AOA TO KSC HAS BEEN ANNOUNCED, WIRE FRAMES LISTED BELOW ARE TO REMAIN IN "CLOSED ACCESS" MODE. A. USB (MILA) B. BRRS C. CDSC - FRAMES 1, 40 AND WT D. LACB - FRAMES 66 AND 74 E. VABR F. TEL 4 G. SO REP H. LCC NOT PERFORMED ______ SS2 1023 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0179 3. IF TAL OR AOA TO DFRC OR CON'T WSSH HAS BEEN ANNOUNCED, WIRE FRAMES LISTED BELOW ARE TO REMAIN IN "CLOSED ACCESS" MODE. A. USB (MILA) B. BRRS C. CDSC - FRAMES 1, 40 AND WT D. VABR E. LCC ALL OTHER FRAMES MAY BE OPENED FOR NORMAL WORK. NOT PERFORMED ______ SS3 NOTE PERFORM NEXT STEP BASED ON SRM ACID CLOUD FORMATION AND WX CONDITIONS. 17-0180 +35M00S *PSE *SCC VAB HIGH BAY AND TRANSFER AISLE CDPA NET DOORS RELEASED TO NORMAL WEATHER SU72A00 105 CONFIGURATION. SU72A44 *SCC NTD 232 NTD STM STM JCTL 111 JCTL VCMP LCC UNDER FLOOR LOCK C/O ------------------------ 17-0181 NTD STM CHANGE FIRING ROOM UNDERFLOOR SEC 232 AREA AND LCC ROOM 2R14 CABLE STM JSTC TUNNEL ACCESS CONTROL LOCKS. 111 REMOVE SECURITY LOCKS AND INSTALL JSTC *SEC LOACS LOCK ON FIRING ROOM UNDER 114 FLOOR AREA AND COMM LOCK ON LCC/2R14 CABLE TUNNEL. 1024 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0182 *SEC JSTC FIRING ROOM UNDERFLOOR AREA AND SEC 114 LCC/2R14 CABLE TUNNEL SECURITY COMM JSTC STM LOCKS HAVE BEEN REMOVED. LOACS 111 LOCK INSTALLED ON FIRING ROOM STM GYCC UNDERFLOOR AREA AND ACCESS IS NOW UNDER LOACS CONTROL. COMM LOCK INSTALLED ON LCC/2R14 CABLE TUNNEL AND ACCESS IS NOW UNDER COMMUNICATIONS CONTROL. 17-0183 +40M00S EEC JYVR STOP VIDEO RECORDING OF OTV COMM 138 CAMERA 080. (SEE EEC FIG. 4). 17-0184 *PSE *SCC EAST/WEST PAD SURFACE INSPECTION NET COMPLETE. 105 *SCC NTD 232 150 PSIG GN2 SECURE ------------------- NOTE PERFORM NEXT STEP IF TSM GN2 PURGES HAVE BEEN SECURED PER OMI S1004. 17-0185 +45M00S CLHY TBC 150 PSIG GN2 FOR LH2/LO2 TSM 136 PURGE PANEL NO LONGER REQUIRED. TBC NTD 232 NTD STM NOT PERFORMED ______ 17-0186 +45M00S STM JSTC 150 PSIG GN2 FOR LO2/LH2 TSM PNU 111 PURGE PANEL NO LONGER REQUIRED. SU72A25 JSTC GSPN SECURE CONTROL STATION PER SU72A45 114 OPERATION INSTRUCTIONS OF M3703. RELEASE PNEUMATIC PERSONNEL AT INDUSTRIAL SUPPLY INTERFACE. (30 MIN) RELEASE GN2 PRODUCTION PLANT. 17-0187 CLHY TBC CHGD SUPPORT NO LONGER REQUIRED. 136 PERFORM SYSTEMS SECURING. TBC CHGD 1025 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF KSC IS THE AOA SITE SELECTION. 17-0188 LSO LRD AOA LANDING SUPPORT IS RELEASED. LFP AIRSPACE CONTROLS ARE NO LRD NCC LONGER REQUIRED. CCN SRO LRD STM ROC EMS SLF STM FSTM 111 JSTC JSTC FSTC 114 JFIR *SEC NOT PERFORMED ______ HAZ GAS SYSTEMS SECURING ------------------------ 17-0189 CHGD CURSOR CNTL (SAW01/HWW13) SU72A09 PUMP 1/2 - OFF MFC POWER - OFF XMIT CURSOR KEY - PRESS 17-0190 CHGD CTMS SECURE HYDROGEN UMBILICAL MASS 177 SPEC (HUMS). REPORT COMPLETION. 17-0191 CHGD TBC HAZ GAS SYSTEMS SECURING COMPLETE. 136 TBC OTC 132 17-0192 LPS JSDC RESTORE PCGOAL TO NORMAL | 127 CONFIGURATION IN LCC2. 17-0193 LPS JRPS CONFIGURE KMTS 0505A1 (A1,A2,A3, | A7,A8,A9) BIT SYNCS TO SOURCE 1. | (MANUAL MODE, SOURCE 1, 60 KB) | 1026 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0194 NTD LPS RELEASE LCC2 FROM S0007 232 SUPPORT AND RECONFIGURE FOR NORMAL SUPPORT. PERFORM POST OPERATION INSTRUCTION 1. CONTINUE POST LAUNCH DATA RETRIEVAL PER S9002, V16. 17-0195 NTD LPS PLACE PP1 AND PP2 PLOTTERS 232 OFF LINE AND REMOVE DATA FOR DATA LPS C2MC COORDINATOR PICKUP. 127 17-0196 NTD LPS REINITIALIZE PP2 SUBSYSTEM. 232 17-0197 LPS C1MC $TERM AND $CLAI PP2 SUBSYSTEM. 1027 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0198 +55M00S OTC CFCP PERFORM PRSD T-0 SYSTEM INERTING SU72A11 132 PER OMI V1040.002 ON OIS CH 153. LOX FARM INSPECTION COMPLETE ---------------------------- 17-0199 *PSE *SCC WEST PAD PERIMETER INSPECTION OF SU72994 NET FUEL FARM AND LO2 STORAGE AREA 105 COMPLETE. READY TO SUPPORT LOX *SCC NTD SAFING CREW ENTRY. WEST PAD 232 PERIMETER INSPECTION CONTINUES. NTD TBC TBC CLOX 136 LOX SAFING TEAM TO PAD ---------------------- 17-0200 CLOX TBC LOX SYSTEM READY FOR STORAGE SU72A28 136 AREA SAFING TEAMS TO BE CLEARED TBC NTD INTO LOX AREA. LOX SAFING CREW 232 IS PROPERLY ATTIRED WITH CLEAN NTD *SCC NON-STATIC PRODUCING FLAME-RETARDANT *SCC *PSE COVERALLS, NON-POROUS FOOTWEAR NET AND SF-APPROVED LEATHER GLOVES. 105 SAFING CREW CONSISTS OF: PLOX PLO2 | PLO4 PLO5 PLO6 *PSE PLO7 PNLO | 17-0201 *SCC NTD PAD CLEAR FOR LOX SAFING CREW ENTRY. 232 SAFING CREW PERSONNEL PROPERLY NTD TBC ATTIRED. YOU HAVE SAFETY TBC CLOX CONCURRENCE TO PROCEED. 136 17-0202 +55M00S NTD STM FIRE CREW PROCEED TO LO2 FIRE 232 STORAGE AREA FOR SAFING SU72A46 STM JSTC OPERATIONS. 111 JSTC JFIR 1028 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0203 +55M00S NTD TBC POSITION OTV CAMERAS IN COMM 232 STM SEQUENCE, TO TRACK LO2 SAFING STM JYVO CREW DURING PAD SAFING AND LO2 138 JYVR SECURING CREW DURING PAD SECURING, START VIDEO RECORDING. 17-0204 CLOX TBC LOX SAFING CREW AT LOX STORAGE 136 AREA. CONTROL AREAS HAVE BEEN TBC NTD ESTABLISHED. REQUEST SAFETY 232 CONCURRENCE TO PROCEED WITH NTD *SCC LOX SYSTEM SAFING. 17-0205 *SCC NTD YOU HAVE SAFETY CONCURRENCE TO SU72A22 232 PROCEED WITH LOX SYSTEM SAFING. SU72A55 NTD TBC TBC CLOX 136 PAD STRUCTURE WASHDOWNS COMPLETE -------------------------------- 17-0206 JBFX STM LAUNCH PAD STRUCTURE AUTOMATIC WSSA 111 WASHDOWN SYSTEM FLOWS COMPLETE. SU72A13 STM NTD 232 NTD *SCC *SCC *PSE 221 1029 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NON-LAUNCH PAD WASHDOWNS COMPLETE --------------------------------- NOTE PERFORM NEXT STEP IF NON-LAUNCH PAD WASHDOWNS WERE REQUIRED. 17-0207 JBFX STM NON-LAUNCH PAD STORAGE AREA WSSA 111 WASHDOWNS COMPLETE. STM NTD 232 NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP UNTIL ALL WASHDOWN WATER FLOWS ARE COMPLETE. 17-0208 +55M00S STM JBFX STOP PUMP P-1. WSSA 111 SU72A47 NOT PERFORMED ______ 17-0209 STM JBWC PERFORM POST LAUNCH DRY CYCLES WSSA 111 OF SOUND SUPPRESSION VALVE COMPLEX AND MLP VALVES PER OMI M3189.001. 1030 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0210 +55M00S NTD *SCC PERFORM ON PAD INSPECTION TEAM SU72A15 232 FUNCTIONS AS SPECIFIED BELOW: *SCC *PSE NET 1. FSS/RSS AREAS 105 A. DIVIDE INSPECTION TEAM INTO 2 GROUPS. B. INSPECT FSS AND RSS IN PARALLEL. 2. RSS A. ALL LEVELS RSS (VISUAL INSPECTION) B. MLP ZERO LEVEL (VISUAL INSPECTION) C. ELEVATOR MACHINE ROOM (207 FT LEVEL) (TOXIC VAPOR/O2 CHECKS) D. PAYLOAD CHANGEOUT ROOM (TOXIC VAPOR/O2 CHECKS) (OR POST SIGNS AT ANTE ROOM AND AIRLOCK DOORS) E. 90 TON HOIST ROOM (TOXIC VAPOR/O2 CHECKS) F. RSS 95 FT CROSSOVER FLEXHOSES (TOXIC VAPOR CK) G. 107 FT FUEL/OXID SKIDS (TOXIC VAPOR CHECKS) H. 207 FT FUEL/OXID SKIDS (TOXIC VAPOR CHECKS) 3. FSS A. ALL LEVELS OF FSS (VISUAL INSPECTION) B. FSS ELEVATOR MACHINE ROOM (TOXIC VAPOR/O2 CHECKS) C. HYPER SCRUBBERS (75 FT LVL) (TOXIC VAPOR CHECKS) 1031 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0211 *PSE *SCC FSS ELEVATOR CONTROL COVER AND NET LOCK INSTALLED. 105 *SCC NTD 232 17-0212 OTC CECL VERIFY S70-1203 SYSTEM AND REFR UNITS POWERED DOWN OR IDENTIFY SUPPORT REQUIRED TO POWER THEM DOWN. 17-0213 *PSE *SCC TWO MAN SLIDEWIRE BUNKER CREW FIRE NET JFIR PROCEEDING TO BUNKER FOR SU72A48 105 SYSTEMS SAFING ON M113. START ELEV INSP/REPAIR ---------------------- 17-0214 +55M00S *PSE *SCC PERFORM ELEVATOR INSPECTION/ CDPD NET REPAIR AND ACTIVATION PER SU72A49 105 OMI Q3018. (TASK COMPLETION *SCC NTD WILL OCCUR IN S2005). 232 NTD STM STM VEEE NET 104 1032 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0215 +55M00S *PSE *SCC MLP SIDE ONE VISUAL INSPECTION NET FROM PAD SURFACE COMPLETE. 105 *SCC NTD 232 17-0216 +01H00M CLHY TBC POST LAUNCH OPERATIONS COMPLETE SU72A29 136 PER S1004. READY TO PERFORM TBC NTD INITIAL LH2 SYSTEM SAFING PER 232 G3254. LH2/OXIDIZER FARM INSPECTION ---------------------------- COMPLETE -------- 17-0217 *PSE *SCC EAST PAD PERIMETER INSPECTION SU72A05 NET OF HYPER OXIDIZER FARM AND LH2 105 STORAGE AREA COMPLETE. READY *SCC NTD FOR SAFING CREW ENTRY TO LH2 NTD TBC STORAGE AND FLARESTACK AREA. 232 EAST PAD PERIMETER INSPECTION CONTINUES. 17-0218 CLHY TBC LH2 SYSTEM READY FOR STORAGE SU72A28 136 AREA AND FLARE STACK SAFING TBC NTD TEAMS TO BE CLEARED INTO LH2 232 AREA. REQUEST SFOC REQUEST SAFETY CONCURRENCE FOR LH2 SAFING TEAMS TO ENTER PAD. VERIFY ALL PERSONNEL ATTIRED IN FLAME RETARDANT BLUE COLLAR COVERALLS AND NON POROUS NON SPARKING SHOES. SAFING CREW CONSISTS OF: PLHY QLHY PLH4 PLH5 PLH6 PLH7 QLH4 PNLH PQC4 QQC4 *PSE 1033 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0219 +01H00M *PSE *SCC PERSONNEL PROPERLY ATTIRED. YOU NET HAVE SFOC SAFETY CONCURRENCE FOR 105 SAFING TEAM TO ENTER LH2 STORAGE *SCC NTD AREA AND FLARE STACK AREA. 232 NTD TBC TBC CLHY 136 17-0220 NTD STM FIRE CREW PROCEED TO LH2 AREA FIRE 232 FOR SAFING OPERATIONS. SU72A46 STM JSTC 111 JSTC JFIR 17-0221 +01H00M NTD TBC POSITION OTV CAMERAS COMM 232 STM IN SEQUENCE TO TRACK LH2 SAFING STM JYVO CREW DURING PAD SAFING AND LH2 138 JYVR SECURING CREW DURING PAD SECURING, START VIDEO RECORDING. 17-0222 NTD *SCC ESTABLISH 200 FT CONTROL AREAS 232 AT GH2 AND LH2 STORAGE FACILITIES. *SCC *PSE NET 105 17-0223 *PSE *SCC SAFETY HAS ESTABLISHED A 200 FT SU72A31 NET CONTROL AREA AT GH2 AND LH2 SU72A56 105 STORAGE FACILITIES. YOU HAVE *SCC NTD CONCURRENCE TO PROCEED WITH INITIAL 232 TBC LH2 SYSTEM SAFING PER OMI G3254. TBC CLHY 136 CLHY PLHY 1034 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT TWO STEPS IF: 1. KSC IS DESIGNATED AOA AND 2. AOA OPTION TO KSC HAS EXPIRED AND 3. EITHER DFRC OR WSSH IS DESIGNATED EOM SITE. 17-0224 +01H00M LRD STM DISABLE KSC TRANSMITTERS AND COMM 135 RECEIVERS ON CONVOY COMMANDER, STM GYCC PURGE AND COOLING NETS. 111 GYCC GYCJ 117 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF ALTERNATE LANDING SITE CONVOY COMMANDER NET ACTIVATED. 17-0225 LRD STM DEACTIVATE ALTERNATE LANDING SITE COMM 135 CONVOY COMMANDER NET FROM ______ STM GYCC (DFRC/WSSH). 111 GYCC GYCJ 117 NOT PERFORMED ______ 1035 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS FOR SCHEDULED EOM AT DFRC. 17-0226 +01H00M LRD STM PERFORM FOLLOWING: 135 STM GYCC 1. IF COMM CIRCUITS WERE COMM 111 PATCHED TO WSSH AS PRIME AOA GYCC GYCJ LANDING SITE FOR THIS MISSION 117 UNPATCH KSC CONVOY COMMANDER FROM WSSH. NOT PERFORMED ______ SS1 2. ACTIVATE DFRC SPA 3/COOLING NET T/R TO KSC COOLING NET. 3. ACTIVATE DFRC SPA 4/CONVOY COMMANDER NET T/R TO KSC CONVOY COMMANDER NET. 4. ACTIVATE DFRC SPA 6/PURGE NET T/R TO KSC PURGE NET. 5. VERIFY DFRC SPA 1 T/R TO OIS CH 135. 6. VERIFY DFRC SPA 8 T/R TO OIS CH 161. NOT PERFORMED ______ 17-0227 GYCC GYCJ PERFORM VOICE CHECKS ON OIS COMM 117 CHANNELS AND RADIO NETS, CONFIGURED FOR DFRC LANDING. NOT PERFORMED ______ 17-0228 GYCJ GYCC COMM CIRCUITS CONFIGURED AND COMM 117 VOICE CHECKED FOR DFRC LANDING. GYCC STM 111 STM LRD 135 NOT PERFORMED ______ 1036 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS FOR SCHEDULED EOM AT WSSH. 17-0229 +01H00M LRD STM PERFORM FOLLOWING: 135 STM GYCC 1. IF COMM CIRCUITS WERE COMM 111 PATCHED TO DFRC AS PRIME AOA GYCC GYCJ LANDING SITE FOR THIS MISSION, 117 UNPATCH KSC CONVOY COMMANDER NET FROM DFRC. NOT PERFORMED ______ SS1 2. ACTIVATE WSSH OIS-A4 CONVOY COMMANDER NET T/R TO KSC CONVOY COMMANDER NET. NOT PERFORMED ______ 17-0230 GYCC GYCJ PERFORM VOICE CHECKS ON COMM 117 COMM CIRCUITS CONFIGURED FOR WSSH LANDING. NOT PERFORMED ______ 17-0231 GYCJ GYCC COMM CIRCUITS CONFIGURED AND COMM 117 VOICE CHECKED FOR WSSH LANDING. GYCC STM 111 STM LRD 135 NOT PERFORMED ______ 1037 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- COMM SYS RECONFIG FOR KSC LANDING --------------------------------- NOTE DO NOT PERFORM NEXT THREE STEPS IF AOA OR ELS TO DFRC OR WSSH HAS OCCURRED. PERFORM NEXT THREE STEPS IF KSC IS SCHEDULED EOM OR AN AOA/ELS TO KSC HAS BEEN ANNOUNCED. 17-0232 +01H00M LRD STM CONFIGURE COMM FOR KSC COMM 135 LANDING: STM GYCC 111 REMOVE PURGE NET, CONVOY GYCC GYCJ COMMANDER NET AND COOLING NET 117 PATCHES FROM DFRC AND CONVOY CMDR NET PATCH FROM WSSH IF PREVIOUSLY ESTABLISHED. NOT PERFORMED ______ 17-0233 LRD STM VERIFY CONVOY CMDR, COOLING COMM 135 AND PURGE NETS T/R CONFIGURED STM GYCC TO KSC. 111 GYCC GYCJ 117 NOT PERFORMED ______ 17-0234 GYCC STM COMM CIRCUITS CONFIGURED COMM 111 FOR KSC LANDING. STM LRD 135 NOT PERFORMED ______ 1038 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP WHEN AOA TO KSC NOT AN OPTION OR WINDOW HAS CLOSED. 17-0235 +01H00M LRD STM KSC SLF NAVAIDS RELEASED FROM COMM 135 S0007 PLUS COUNT SUPPORT. STM GYCC SUPPORT KSC LANDING OPPORTUNITIES 111 PER MISSION UNIQUE ORBIT GYCC FTAC OPPORTUNITIES SCHEDULE. 117 FMLS MLP ZERO LEVEL INSPECTION COMPLETE ---------------------------------- 17-0236 +01H00M *PSE *SCC MLP ZERO LEVEL INSPECTION SU72A19 NET COMPLETE. MLP ZERO LEVEL SU72A57 105 SECURED. ACCESS NOW RESTRICTED *SCC NTD TO DEBRIS INSPECTION TEAM AND 232 PERSONNEL INSTALLING HANDRAILS. DEBRIS INSPECTION TEAM OPS (MLP) -------------------------------- 17-0237 NTD *SCC DEBRIS INSPECTION TEAM MAY START SU72A17 232 INSPECTION OF MLP SURFACE AREA *SCC *PSE (95 FT LEVEL). NET 105 (4 DEBRIS INSPECTION ENGINEERS) ACTIVATE ADMIN PAGING --------------------- 17-0238 +01H00M NTD STM ACTIVATE ADMIN PAGING COMM 232 TO PAD. REPORT COMPLETION. SU72A50 STM GYCC 111 GYCC JYCJ 117 RECONFIGURE ER WX STA CKT ------------------------- 17-0239 NTD STM RECONFIGURE ER WX STA CKT COMM 232 2BPC077 FROM LCC 1/3 OSR CONSOLE STM GYCC A5 TO LCC PRE-LAUNCH MONITOR 111 CONSOLE. 1039 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0240 GYCC JYCJ RECONFIGURE ER WX STA CKT COMM 117 2BPC077 FROM LCC 1/3 OSR CONSOLE A5 PT TO PT PHONE TO LCC RM 1P12A PRE-LAUNCH MONITOR CONSOLE. VERIFY WHEN CIRCUIT OPERATIONAL. 17-0241 STM JYVO STOP VIDEO RECORDING OF OTV COMM 138 CAMERA 073/173. SWITCH COUNT CLOCK SOURCE ------------------------- 17-0242 +01H00M NTD STM SWITCH FROM LPS COUNT TO LOCAL 232 GENERATOR NO. 1. STM JTCR 111 17-0243 +01H00M STM GYCC IF PREVIOUSLY REMOVED, COMM 111 PICK UP AREA WARNING KEYS FROM GYCC JYCJ STM IN PRIME CONTROL ROOM AND 117 JSOQ INSTALL ONE MICROPHONE AND ONE KEY PTP IN EACH CONSOLE AREA WARNING PANEL DESIGNATED BY NTD/STM. ATTACH INTEGRITY CONTROL STICKERS TO SECURE KEY IN KEY HOLE. (30 MIN) LCC-1 CONSOLE AB-6 NOT PERFORMED ______ LCC-2 CONSOLE AA-5 NOT PERFORMED ______ LCC-3 CONSOLE AB-6 NOT PERFORMED ______ NOT PERFORMED ______ 17-0244 STM GYCC CONFIGURE OIS-D COMMUNICATIONS COMM 111 IN PRIME CONTROL ROOM CONSOLES GYCC JYCD AB-5, AB-6, AB-7 AND AB-8 TO 117 SINGLE CHANNEL TRANSMIT CAPABILITY. (30 MIN) 1040 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0245 +01H05M *PSE *SCC WEST PAD PERIMETER INSPECTION SU72995 NET COMPLETE AND INSPECTION TEAM HAS 105 RETURNED TO PAD GATE. SENDING SAFING *SCC NTD CREW TO PTCR FOR TOXIC VAPOR CHECKS 232 AND LOCKING OF ECS GN2 VAVLES. NTD OTC STM PERIMETER INSPECTION COMPLETE ----------------------------- 17-0246 +01H05M *PSE *SCC EAST PAD PERIMETER INSPECTION SU72A04 NET COMPLETE. 105 *SCC NTD 232 NTD TBC OTC STM 17-0247 +01H10M STM JYVR TERMINATE VIDEO TRACKING AND COMM 138 JYVO RECORDING OF SAFETY PERIMETER INSPECTION TEAM. 17-0248 *PSE *SCC O2 AND/OR TOXIC VAPOR CHECKS NET COMPLETE FOR FOLLOWING AREAS 105 AND AREA IS EITHER: *SCC NTD C = CONTROLLED 232 O = OPEN FOR CONTROLLED WORK 1. RSS 95 FT CROSSOVER FLEXHOSES _____ 2. RSS 107 FT HYPER SKIDS _____ 3. PAYLOAD CHANGEOUT ROOM _____ 4. 207 FT HYPER SKIDS _____ 5. 207 FT LEVEL ELEV MACH RM _____ 6. 207 FT LEVEL 90 TON HOIST RM _____ 7. FSS SCRUBBERS _____ 8. FSS ELEV MACH ROOM _____ 1041 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0248 9. HYPERGOLIC FUEL FARM _____ CON'T 10. HYPERGOLIC OXIDIZER FARM _____ 11. PAD CATACOMBS (EAST AND WEST) _____ 17-0249 +01H10M GSPN JSTC LPGN2 SECURING COMPLETED. PNU 114 CCF-39 GN2 PRODUCTION PLANT SU72A51 JSTC STM HIGH FLOW LPGN2 SUPPORT 111 TERMINATED. STM NTD 232 PRSD T-0 SYSTEM INERTING COMPLETE --------------------------------- 17-0250 CFCP OTC PRSD T-0 SYSTEM INERTING PER 132 V1040.002 COMPLETE. OTC NTD 232 NTD TBC *SCC *SCC *PSE NET 105 17-0251 STM JBPN PERFORM POST LAUNCH INSPECTION PNSA 111 OF AIR COMPRESSORS PER OMI M3022 REPORT COMPLETION. (1HR) (APPENDIX C) NOTE PERFORM NEXT STEP IF CAMERA PURGE WAS ACTIVATED. 17-0252 STM JBPN CLOSE PURGE SUPPLY VALVES TO PNSA 111 CAMERAS 070 AND 071 (PAD A) OR 170 AND 171 (PAD B). RECORD SUPPLY PRESSURES 070/170__________PSI BD 071/171__________PSI BD NOT PERFORMED ______ 1042 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0253 *PSE *SCC ALL REQUIRED PERSONNEL ON SITE SU72995 NET AT PTCR/ECS ROOM TO PERFORM SU72996 105 TOXIC VAPOR CHECKS, GN2 VALVE *SCC NTD SECURING AND DEPRESSURIZATION 232 OPERATIONS. 17-0254 +01H20M NTD STM PERFORM FOLLOWING: 232 STM JBAC 1. DEPRESSURIZE PTCR/ECS ROOMS HVAA 111 BY OPENING ECS ROOM DOOR AND RESTRAINING IN OPEN POSITION. T:______ SS1 2. CLOSE RSS/MLP AUTO DRAIN VALUES FROM C-2 CONSOLE IF PREVIOUSLY OPENED. NOT PERFORMED ______ SS2 17-0255 STM JBAC CLOSE RSS/MLP MANUAL DRAIN HVAA VALVES IN PTCR ROOM 105. T:______ 17-0256 *PSE *SCC PTCR/ECS ROOM DOOR OPENED, O2 HVAA NET AND TOXIC VAPOR CHECK ACCEPTABLE. 105 *SCC NTD 232 NTD STM STM JBAC 111 1043 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SOUND SUPPRESSION DRY CYCLE --------------------------- OPS COMPLETE ------------ 17-0257 JBWC STM POST LAUNCH DRY CYCLES OF SOUND WSSA 111 SUPPRESSION VALVES COMPLETE. SECURE ECS (V1122) ------------------ 17-0258 +01H20M NTD OTC SECURE THE ECS GN2 MANUAL SU72997 232 *SCC ISOLATION VALVES PER OMI V1122 OTC CPVD "TERMINATION OF ECS HAZ PURGE 132 GN2 OPERATION." *SCC *PSE NET 105 RT OMI LOG NO.__________ 17-0259 +01H30M *PSE *SCC ECS GN2 HAND VALVES LOCKED. NET CONTINUING WITH UPPER AND LOWER 105 PTCR 02 CHECKS. *SCC NTD 232 17-0260 +01H30M CPVD OTC ECS RM GN2 VALVES CLOSED AND SU72997 132 LOCKED. READY TO CONTINUE WITH OTC NTD CONTROL STATION TRANSFER TO PAD. 232 NTD *SCC *SCC *PSE NET 105 17-0261 +01H30M NTD STM COMPLETE PTCR/ECS ROOM HVAA 232 DEPRESSURIZATION AND REMOVE SU72A01 STM JBAC PTCR EXHAUST FANS 1 AND 2 111 BLAST COVERS PER OMI M3034. 17-0262 +01H30M OTC CPVD PERFORM CONTROL STATION TRANSFER SU72A02 132 PER OMI V1122. RT OMI LOG NO.__________ 1044 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MLP O2 LEVEL - OK ----------------- 17-0263 +01H30M JBEP STM O2 ANALYZERS INDICATE ACCEPTABLE PWR 111 O2 LEVELS IN MLP. RECORD ANY MLP SU72A03 STM NTD COMPARTMENTS INDICATING LOW O2 232 LEVELS OR TROUBLE MODE: NTD *SCC ________________________________ *SCC *PSE NET _________________________________ 105 17-0264 NTD ALL IF LOW O2 CONDITIONS RECORDED 232 REQUIRING MLP RE-ENTRY, PROCEED TO S0007VL5 SEQ 120. NOT PERFORMED ______ WARNING NO ACCESS INTO MLP ALLOWED UNTIL GN2 HAND VALVE CLOSED AND LOCKED. 17-0265 +01H30M NTD *SCC PROCEED WITH MLP INTERIOR 02 AND SU72A06 232 TOXIC VAPOR CHECKS. *SCC *PSE NET 105 17-0266 +01H30M STM JBDY HAVE STRUCTURES PERSONNEL AND STSA | 111 HEAVY EQUIPMENT REPORT TO PAD HESA NET QBSE GATE FOR PAD/MLP HANDRAIL SU72A33 104 OPERATIONS. JBDY GBHE NET 104 17-0267 +01H30M CLOX TBC RESIDUAL LOX PURGING AFTER LAUNCH 136 COMPLETE PER G3153. CONTINUING TBC NTD WITH LOX SYSTEM SAFING. 232 1045 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0268 +01H30M JYCJ GYCC ER WX STA CKT 2BPC077 COMM 117 RECONFIGURED FROM LCC 1/3 OSR GYCC STM CONSOLE A5 TO PRE-LAUNCH MONITOR 111 CONSOLE AND IS OPERATIONAL. STM NTD 232 17-0269 JYCD GYCC CONSOLES AB-5, AB-6, AB-7 AND COMM 117 AB-8 IN PRIME CONTROL ROOM HAVE GYCC STM BEEN CONFIGURED TO SINGLE CHANNEL 111 TRANSMIT CAPABILITY. STM NTD 232 17-0270 +01H30M JYCJ GYCC IF PREVIOUSLY REMOVED, COMM 117 AREA WARNING KEYS AND MICROPHONES GYCC STM HAVE BEEN INSTALLED IN AREA 111 WARNING PANELS AND KEYS SECURED STM NTD IN KEY HOLES WITH INTEGRITY 232 CONTROL STICKER IN FOLLOWING CONSOLES: LCC-1 CONSOLE AB-6 NOT PERFORMED ______ LCC-2 CONSOLE AA-5 NOT PERFORMED ______ LCC-3 CONSOLE AB-6 NOT PERFORMED ______ NOT PERFORMED ______ 17-0271 +01H30M *PSE *SCC UPPER AND LOWER PTCR 02 SU72999 NET CHECKS COMPLETE. 105 *SCC NTD 232 DROP ROADBLOCKS --------------- 17-0272 +01H30M *PSE *SCC ALL SAFING TEAMS HAVE ENTERED SU72A07 NET PAD, DROP BDA ROADBLOCKS. ACCESS 105 TO PAD AND CLOTHING REQUIREMENTS *SCC NTD WILL BE CONTROLLED BY PAD SITE 232 MANAGER AND SFOC SAFETY. 1046 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0273 NTD *SEC DROP ROADBLOCKS A-3, A-5, SEC 232 STM A/B-4, A-6 (PAD A LAUNCH), STM JSTC A/B-4, B-3 (PAD B LAUNCH). 111 17-0274 *SEC NTD ROADBLOCKS A-3, A-5, A/B-4, A-6 SEC 232 (PAD A LAUNCH), A/B-4, B-3 (PAD B NTD OTC LAUNCH) DROPPED. BDA CLEARS 232 TBC REDUCED TO PAD ___ GATE. STM *SCC *SCC *PSE NET 105 STM JSTC 111 OTC *PAD 132 NOTE PERFORM THE FOLLOWING TWO STEP IF SRM SEGMENT RAILCARS WERE MOVED FROM BEACH SIDING TO BALLOON SIDING. 17-0275 STM JSTC MOVE _____SRM SEGMENT RAILCARS FROM BALLOON SIDING TO BEACH SIDING. NOT PERFORMED ______ 17-0276 JSTC STM _____SRM SEGMENT RAILCARS RELOCATED 111 FROM BALLOON SIDING TO BEACH SIDING. STM NTD (PHONE 1-5108) 232 *OPS NOT PERFORMED ______ 1047 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 TRANSFER LINE SHUTOFF BLOCK ------------------------------- VLV CLOSED ---------- 17-0277 +01H35M PLHY CLHY LH2 INITIAL SYSTEM SAFING SU72A31 166 COMPLETE AND A3401 TRANSFER LINE SU72A33 CLHY TBC SHUT-OFF BLOCK VALVE CLOSED. 136 TBC NTD 232 NTD *SCC 1048 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- LH2 MLP SAFING -------------- 17-0278 CLHY TBC MLP PURGE INITIATED. REQUEST SU72A35 136 SAFETY CONCURRENCE FOR SAFING TEAMS TBC NTD TO PROCEED FROM LH2 SHOP TO MLP 232 SIDE 1 AND FROM LH2 STORAGE AREA NTD *SCC TO LH2 FLARESTACKS. 17-0279 +01H35M *SCC NTD YOU HAVE SFOC SAFETY CONCURRENCE FOR 232 MLP TEAM TO PROCEED TO MLP SIDE ONE NTD TBC AND FLARE STACK TEAM TO PROCEED TO LH2 TBC CLHY FLARE STACKS. USE ACCESS LADDER ON 136 EITHER SIDE OF MLP PEDESTAL. CLHY PLHY 17-0280 TBC CLHY PERFORM LH2 MLP SAFING. 136 FSS & RSS INITIAL INSPECTION COMPLETE ------------------------------------- 17-0281 +01H35M *PSE *SCC FSS & RSS INITIAL AND TOXIC SU72A15 NET INSPECTION COMPLETE. SAFETY 105 SIGNS INSTALLED. *SCC NTD 232 NTD OTC STM 1049 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GO2/GH2 CROSS-COUNTRY LINE SECURING ----------------------------------- 17-0282 CFCP OTC READY TO START GO2/GH2 CROSS SU72A63 132 COUNTRY LINE SECURING. REQUEST OTC NTD SAFETY CONCURRENCE TO PROCEED. 232 NTD *SCC *SCC *PSE NET 105 17-0283 *PSE *SCC CONTROL AREA REMAINS CLEAR. YOU HAVE NET SAFETY CONCURRENCE TO PROCEED WITH 105 GO2/GH2 CROSS COUNTRY LINE SECURING. *SCC NTD 232 NTD OTC 17-0284 OTC CFCP CLOSE PRSD GO2 PANEL ISOLATION VALVE 132 (830-1 PNL ON 75 FT LVL) TO SUPPORT JBPN FOR GO2/GH2 CROSS-COUNTRY LINE SECURING PER V1040.002. 17-0285 +01H15M CFCP OTC PRSD GO2 PANEL ISOLATION VALVE PNSA 132 CLOSED. CFCP READY TO SUPPORT OTC NTD JBPN FOR GO2/GH2 CROSS-COUNTRY 232 LINE SECURING ON OIS CH 122. NTD STM STM JBPN 111 17-0286 NTD STM PERFORM GO2 CROSS-COUNTRY LINE PNSA 232 SECURING PER POST OPERATION SU72A52 STM JBPN INSTRUCTIONS OF OMI M3097. 111 17-0287 +01H15M NTD STM PERFORM GH2 DISTRIBUTION SYSTEM PNSA 232 SECURING PER POST OPERATION STM JBPN INSTRUCTIONS OF OMI M3020. 111 17-0288 +01H15M NTD CONTACT PAO (7-7819) TO ALLOW FILM RETRIEVAL PERSONNEL TO PROCEED TO BDA ROADBLOCK. STAND BY AT BDA ROADBLOCK FOR ACCESS TO PAD PERIMETER CAMERA SITES. (15 MIN) 1050 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0289 +01H40M STM JBDY PERFORM FOLLOWING: 111 NET QBSE 1. INSTALL CABLE AND POSTS AT STSA | 104 FWD END OF FLAME TRENCH. JBDY GBHE (M3134) NET 104 T:______ SS1 2. INSPECT AND REPLACE FLOOR STSA | PANELS IN MLP, A AND B LEVELS. T:______ SS2 3. MOVE FLATBED TRUCK WITH HESA HANDRAILS AND MOBILE CRANE FROM PAD GATE TO PAD SURFACE EAST SIDE AND PREPARE FOR LIFTING OPERATIONS. DO NOT LIFT HANDRAILS OVER CRYO LINES UNTIL GH2 IS VERIFIED LESS THAN 1 PCT AT MLP SIDE 1. T:______ SS3 4. POSITION MONITOR SHACKS ON HESA 135 FT LEVEL RSS AND PAD SURFACE AND POSITION TETHER STATION ON PAD SURFACE. T:______ SS4 1051 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0289 5. INSTALL STRUCTURE TIE-DOWNS STSA | CON'T ON ACCESS MONITOR SHACK 135 FT LEVEL RSS AND SECURE GUARD SHACK AND TETHER STATION ON PAD SURFACE. REPORT COMPLETION. T:______ SS5 17-0290 CPVD OTC TRANSFER OF ECS ROOM TO LOCAL HVAA 132 CONTROL COMPLETE. SUPPORT FOR SU72A02 OTC NTD V1122 NO LONGER REQUIRED. 232 NTD STM STM JBAC 111 17-0291 CPVD PPVM PERFORM POST LAUNCH SECURING 172 (LOCAL) INCLUDING SEQ "MAIN BLOWER CHANGEOVER OPERATIONS" AND SEQ "DOCK SEAL/INSPECTION ECS SYSTEM RELATIVE HUMIDITY SENSOR CALIBRATION, REMOVAL AND INSTALLATION" PER OMI V1122. (COMPLETION VERIFICATION NOT REQUIRED). 1052 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DEBRIS INSPECTION TEAM OPS -------------------------- (PAD PERIMETER) --------------- 17-0292 +01H45M NTD *SCC DEBRIS INSPECTION TEAM MAY BE 232 CLEARED THRU PAD GATE AT THIS TIME *SCC *PSE TO PERFORM POST-LAUNCH PAD DEBRIS NET INSPECTION. THIS INSPECTION WILL 105 BE CONDUCTED FROM PAD PERIMETER TO APRON ONLY, EXCLUDING FOLLOWING LISTED AREAS: 1. LO2 FACILITIES 2. LH2 FACILITIES 3. GO2 FACILITIES 4. GH2 FACILITIES 17-0293 NTD *ICE PERFORM DEBRIS INSPECTION OF PAD SU72A10 232 TBC AREA, PERIMETER TO APRON ONLY, *SCC PER OMI S6444. EXCLUDE FOLLOWING *SCC *PSE LISTED AREAS: NET 105 1. LO2 FACILITIES 2. LH2 FACILITIES 3. GO2 FACILITIES 4. GH2 FACILITIES OMRSD S00U00.010-1 PTCR/ECS ROOM DEPRESS COMPLETE ------------------------------ 17-0294 +01H50M JBAC STM PTCR/ECS RM DEPRESS COMPLETE. HVAA 111 UPPER AND LOWER BLAST DOORS OPEN. STM NTD 232 NTD *SCC *SCC *PSE NET 105 1053 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- INITIAL LO2 SAFING - COMPLETE ----------------------------- 17-0295 CLOX TBC LOX SYSTEM SAFING COMPLETE. SU72A24 136 REQUEST SAFETY CONCURRENCE TO TBC NTD OPEN LOX STORAGE AREA CONTROL 232 AREA FOR CONTROLLED WORK. NTD *SCC 17-0296 *SCC NTD YOU HAVE SAFETY CONCURRENCE TO 232 OPEN LOX STORAGE AREA CONTROL NTD TBC AREA FOR CONTROLLED WORK. "E" TBC CLOX ROAD WILL REMAIN CLOSED UNTIL LOX 136 DUMP BASIN BOILOFF IS COMPLETE. 17-0297 CLOX TBC LOX STORAGE IS OPEN FOR CONTROLLED 136 WORK. "E" ROAD WILL REMAIN CLOSED TBC NTD UNTIL LOX DUMP BASIN BOILOFF IS 232 COMPLETE. PROCEEDING WITH LOX NTD *SCC AREA SECURING. 17-0298 NTD STM FIRE COMBAT CREW AT LOX STORAGE FIRE 232 AREA MAY BE RELEASED BACK TO STM JSTC FIRE STATION NO. 6 TO SUPPORT 111 CONTINUED PAD POST LAUNCH SAFING/ JSTC JFIR SECURING OPERATIONS. FIRE COMBAT 114 CREW AT LH2 STORAGE AREA TO REMAIN AT LH2 STORAGE AREA FOR CONTINUED POST LAUNCH SECURING OPERATIONS PER S2005. INITIAL MLP LH2 SAFING COMPLETE ------------------------------- 17-0299 CLHY TBC MLP SAFING COMPLETE. LESS THAN SU72A12 136 1 PCT GH2 VERIFIED ON MLP SIDE 1. SU72A35 TBC NTD 232 NTD *SCC 1054 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0300 CLHY TBC VERIFY CONCURRENCE FOR ET LH2 SU72A36 136 SAFING PERSONNEL TO PROCEED TO TBC NTD FSS TO PERFORM FSS SECURING 232 ON 195 AND 203 FT LEVELS. NTD *SCC 17-0301 +02H00M *SCC NTD ET LH2 SAFING PERSONNEL MAY 232 PROCEED TO FSS AND PERFORM FSS NTD TBC SAFING AND SECURING ON 195 AND TBC CLHY 203 FT LEVELS. 136 CLHY PLHY NOTE VERIFICATION OF LESS THAN 1 PERCENT GH2 ON MLP SIDE 1 MUST BE COMPLETE PRIOR TO HANDRAIL LIFTING OPS. 17-0302 +02H00M STM NTD VERIFY CONCURRENCE TO PERFORM SSME 232 FLAME HOLE HANDRAIL LIFT AND NTD *SCC INSTALLATION. SAFETY WILL ENSURE *SCC *PSE ALL PERSONNEL WORKING WITHIN 6 FT NET OF MLP FLAME DUCTS ARE WEARING 105 SAFETY HARNESS/BELT WITH LANYARD SECURED TO APPROVED TIE OFF POINT. NOTE HANDRAIL INSTALLATION CONTINUES IN WORK AND WILL BE COMPLETED IN S2005. 17-0303 +02H00M *PSE *SCC YOU HAVE SAFETY CONCURRENCE TO SU72A14 NET PROCEED WITH SSME FLAME HOLE SU72A59 105 HANDRAIL LIFT AND INSTALLATION. *SCC NTD 232 1055 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- WARNING NEXT STEP IS HAZARDOUS DUE TO PERSONNEL WORKING AT HEIGHTS WITHIN 6 FT OF UNPROTECTED EDGES. PERSONNEL WILL WEAR SAFETY HARNESS WITH LANYARD ATTACHED TO APPROVED TIE OFF POINT. 17-0304 +02H00M NTD STM PERFORM FOLLOWING: 232 STM JBDY 1. INSTALL MLP HANDRAILS PER STSA | 111 OMI M3083. NET QBSE 104 2. INSTALL LADDERS TO PROVIDE ACCESS TO LEFT AND RIGHT SRB AFT SKIRT GN2 PURGE NEAR HDP NO. 2 AND HDP NO. 6. T:______ NOTE FOR ANY MLP COMPARTMENTS IN WHICH ODMS CANNOT BE RESET AND MADE FUNCTIONAL, S0007 SAFING/SECURING OPERATIONS ONLY MAY RESUME IN AFFECTED COMPARTMENTS PROVIDED PORTABLE O2 MONITOR IS USED AND SAFETY CONCURS. 17-0305 +02H00M *PSE *SCC INITAL SAFETY MLP INTERIOR SWEEP PWRA | NET AND TOXIC VAPOR CHECKS COMPLETE. SU72A06 105 READY FOR SPECIAL POWERS SU72A43 *SCC NTD GROUP TO RESET O2 ANALYZERS 232 REQUIRING RESET AS LISTED BELOW: NTD STM ____________________________ STM JBEP ____________________________ 111 ____________________________ 1056 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0306 STM JBEP PERFORM POST LAUNCH INSPECTION PWRA | 111 PER OMI M3088 AND RESET ANY MLP | O2 ANALYZERS REQUIRING RESET AND SU72A16 SILENCE O2 ALARMS. LIST COMPARTMENTS WHERE O2 ANALYZER RESET UNATTAINABLE. REPORT COMPLETION. ______________________________ ______________________________ NOTE PERFORM NEXT STEP ONLY IF THERE WERE COMPARTMENTS WHERE O2 ANALYZER RESET UNATTAINABLE. 17-0307 NTD SCC INSTALL PORTABLE 02 MONITOR(S) 232 WHILE RESET UNATTAINABLE. *SCC *PSE NET 105 NOT PERFORMED ______ 17-0308 +02H20M *PSE *SCC MLP INTERIOR O2 AND TOXIC VAPOR NET CHECKS COMPLETED. OXYGEN MONITORING 105 SYSTEM OPERATIONAL. MLP OPEN FOR *SCC NTD S0007 SECURING OPERATIONS ONLY. 232 NTD TBC OTC STM TBC CLOX 136 CLHY 17-0309 +02H20M NTD JFIR MLP IS BEING DEPRESSURIZED. IF FIRE 232 FIRE ALARM IS ACTIVATED PERFORM SU72A18 THREE RESETS BEFORE DISPATCHING FIRE RESCUE. 1057 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0310 NTD STM PERFORM FOLLOWING AND VERIFY HVAA 232 *SCC COMPLETION: STM JBAC 111 1. DEPRESSURIZE MLP PER OMI M3079 AND REMOVE GSS SIGNS. 2. DEPRESSURIZE FSS EMR, RSS HMR, AND EMR PER OMI M3079 AND REMOVE GSS SIGNS. 3. OPEN MLP/RSS BLOCKING VALVES (IF CLOSED). NOT PERFORMED ______ SS3 4. IF AUTO CHILLED WATER DRAIN WAS ACCOMPLISHED, REFILL CHILLED WATER SYSTEM PER OMI M3079. NOT PERFORMED ______ SS4 5. INSPECT RSS/FSS FOR CHW PIPING AND AHU DAMAGE/LEAKAGE. REPORT TO JBAC. NOTE PERFORM NEXT SUBSTEP IF VALVES PREVIOUSLY CLOSED. 6. OPEN RSS MANUAL ISOLATION VALVES. NOT PERFORMED ______ SS6 NOTE PERFORM NEXT SUBSTEP IF BLOCKING VALVES WERE CLOSED AT LAUNCH. 7. START BOOSTER PUMP P-8 OR P-9. NOT PERFORMED ______ SS7 1058 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0310 8. LOWER PRIME AND VENTILATION CON'T AIR DUCTS BLAST SHIELDS. 17-0311 NTD ATTENTION ON MLP PAD _____: PA MLP IS BEING DEPRESSURIZED. DEPRESSURIZATION MAY ACTIVATE FIRE ALARMS. DISREGARD MLP FIRE ALARM BELLS AND BEACONS. 17-0312 +02H20M CLOX TBC VERIFY SFOC SAFETY CONCURRENCE SU72A26 136 FOR LOX SECURING CREW TO ENTER TBC NTD MLP. 232 NTD *SCC SECURING CREW CONSISTS OF *SCC *PSE NET QLOX MLP, LOX LEAD ENGR, ROVING 105 QLO4 MLP, LOX TECH QLO5 MLP, LOX TECH *PSE SFOC SAFETY ENGR PNLO PAD, LOX ENGR (NASA) | 17-0313 *PSE *SCC YOU HAVE SAFETY CONCURRENCE FOR SU72A27 NET LOX SECURING CREW TO ENTER MLP. 105 *SCC NTD 232 NTD TBC TBC CLOX 136 508 GCU/FREON SYSTEM SECURING ----------------------------- NOTE CUT SAFETY WIRE (IF INSTALLED) TO CLOSE VALVES. 17-0314 +02H25M OTC *PAD IN MLP COMPARTMENT 43A, CLOSE 132 QMTG FOLLOWING FREON VALVES, LOCATED OVERHEAD IN CEILING. SUPPLY A87743-CLOSE RETURN A87744-CLOSE T:______ 1059 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0315 OTC NTD FSS BREATHING AIR SYSTEM NO PNSA 232 LONGER REQUIRED. NTD STM STM JBPN 111 HYDROGEN LESS THAN 1 PCT AT FSS ------------------------------- 203 FT AND 155 FT LVLS ---------------------- 17-0316 +02H30M CLHY TBC LESS THAN 1 PCT GH2 VERIFIED IN SU72A37 136 ET LH2 VENT LINE (FSS 195 FT). TBC NTD SUPPORT MAY BE RELEASED FROM FSS 232 195 FT LEVEL. NTD *SCC LH2 STORAGE AREA SAFING AND SECURING ------------------------------------ 17-0317 CLHY TBC LH2 FLARE STACK SUPPORT FOR FSS SU72A38 136 SAFING AND SECURING NO LONGER SU72A39 TBC NTD REQUIRED. FLARE STACK AREA CLEARED. 232 REQUEST CONCURRENCE TO PERFORM NTD *SCC LH2 STORAGE AREA SAFING AND SECURING PER G3254. 17-0318 *SCC NTD FLARE STACK AREA CLEARED. 232 PERFORM LH2 STORAGE AREA SAFING NTD TBC AND SECURING PER OMI G3254. TBC CLHY 136 1060 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE LOX SECURING MAY BE PERFORMED IN PARALLEL WITH ETVAS ORDNANCE OPS. 17-0319 CLOX TBC VERIFY FSS 215 FT LEVEL OPENED SU72A30 136 FOR LOX SECURING CREW ENTRY. TBC NTD SECURING CREW CONSISTS OF: 232 NTD *SCC *SCC *PSE NET PLOX PAD LEAD LOX ENGR 105 PLO4 PAD LOX TECH PLO5 PAD LOX TECH *PSE SFOC SAFETY ENGR PNLO PAD LOX ENGR (NASA) | 17-0320 *PSE *SCC FSS 215 FT LEVEL OPENED FOR LOX NET SECURING CREW ENTRY. YOU HAVE 105 SAFETY CONCURRENCE TO PROCEED. *SCC NTD 232 | NTD TBC TBC CLOX 136 1061 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0321 TBC NTD REQUEST SAFETY CONCURRENCE FOR 232 ETVAS ORDNANCE SAFING AND T-0 NTD *SCC LOCK ORDNANCE SAFING TEAMS TO *SCC *PSE PROCEED TO FSS TO PERFORM FSS NET SECURING AND ORDNANCE REMOVAL ON 105 FSS 135 AND 203 FT LEVELS. 17-0322 TBC NTD REQUEST SAFETY ESTABLISH 25 FT 232 CLEAR FOR ETVAS ORDNANCE AND NTD *SCC T-0 LOCK ORDNANCE REMOVAL *SCC *PSE PER T5448. NET 105 17-0323 *PSE *SCC SAFETY VERIFIES 25 FT CONTROLS NET ESTABLISHED AND CONCURRENCE TO 105 PROCEED WITH ETVAS ORDNANCE AND *SCC NTD T-0 LOCK ORDNANCE REMOVAL 232 PER OMI T5448. NTD TBC 17-0324 +02H30M TBC *PAD PERFORM FIRE LINE DISCONNECTIONS SU72A32 136 AND EXPENDED PYRO SEPARATOR ASSYS REMOVAL PER OMI T5448 ON CH 186. 17-0325 +02H30M CLHY TBC ATTENTION ON PAD___: LH2 VAPORIZERS 136 WILL BE VENTED TO LH2 FACILITY TBC NTD FLARE STACK FOR ONE HOUR. ALL 232 PERSONNEL REMAIN CLEAR OF 150 FT NTD RADIUS AROUND LH2 FLARE STACK BASE. PA 17-0326 +02H45M JBPN STM GO2/GH2 CROSS COUNTRY LINE PNSA STM NTD SECURING PER M3020/M3097 SU72A52 232 OTC COMPLETE. NTD *SCC *SCC *PSE NET 105 1062 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PRSD FCSS SYSTEM SECURE AND --------------------------- POWER DOWN ---------- 17-0327 NTD OTC PERFORM PRSD FCSS SECURE AND SU72A08 232 POWER DOWN PER OMI V1040.002. OTC CFCP 132 17-0328 PGCU FSS 75 FT LEVEL CLOSE GCU ISOLATION VALVES A87806 AND A87809. T:______ 17-0329 +02H55M JBAC STM MLP DEPRESSURIZED. HVAA 111 SU72A18 STM NTD 232 NTD OTC TBC *SCC *SCC *PSE NET 105 17-0330 NTD JFIR MLP DEPRESSURIZATION COMPLETE. FIRE 232 ACKNOWLEDGE MLP FIRE ALARM ANNUNCIATIONS AS VALID. 17-0331 NTD ATTENTION ON MLP PAD _____ PA MLP DEPRESSURIZATION COMPLETE. RESPOND TO ALL MLP FIRE ALARM BELLS AND BEACONS. 17-0332 NTD STM AFTER VERIFYING WITH ALARM FIRE 232 TECHS THAT MLP HALON IN MANUAL STM JSTC OVERRIDE MODE, PLACE HALON IN MANUAL 111 LCC (1P10). RECONFIGURE MLP HALON JSTC JFIR REMOTE (AUTO/MANUAL) SWITCH TO 114 NORMAL POSITION. MLP HALON TO REMAIN IN MANUAL MODE. 1063 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0333 CFCP OTC PRSD FCSS SECURE AND POWER SU72A08 132 DOWN COMPLETE. OTC NTD 232 17-0334 *SCC NTD VERIFY ITEMS LISTED BELOW COMPLETE 232 BEFORE OPENING PAD FOR CONTROLLED WORK. IF ALL SUBSTEPS NOT COMPLETE, PORTIONS OF PAD CAN BE OPENED ONLY WITH NTD AND *SCC CONCURRENCE. 1. LH2/LO2 AREA CONTROLLED(___/___) 2. MLP 0-LEVEL CONTROLS ESTABLISHED (______) 3. WEST/EAST INITIAL PAD INSPECTION COMPLETE(___/___) 4. ECS/PTCR UPPER AND LOWER O2/TVC CHECK(___/___) 5. ECS GN2 MANUAL VALVES CLOSED AND LOCKED(______) 6. LH2 BLOCK VALVES CLOSED(______) 7. FSS/RSS INITIAL PAD INSPECTION COMPLETE(______) 8. MLP SIDE 1 LESS THAN 1 PCT GH2 (______) 9. MLP INTERIOR O2/TVC CHECK(_____) 10. 155 FT/203 FT FACILITY/ET VENT LINES LESS THAN ONE PCT GH2(______) 1064 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 17-0335 +03H15M NTD *SCC ITEMS LISTED IN PREVIOUS STEP 232 OTC HAVE BEEN COMPLETED OR AREAS STILL TBC CLASSIFIED AS HAZARDOUS VERIFIED STM CONTROLLED. PTC LIST CONTROLLED AREAS:_____________ *SCC *PSE ___________________________________ NET ___________________________________ 105 VERIFY READY TO OPEN PAD FOR CONTROLLED WORK. PAD OPEN FOR CONTROLLED WORK ---------------------------- 17-0336 *PSE *SCC PAD___ OPEN FOR CONTROLLED SU72A20 NET WORK. SU72A61 105 *SCC NTD 232 17-0337 NTD *SEC OPEN PAD ___ GATE FOR SEC 232 CONTROLLED WORK. REPORT COMPLETION. 17-0338 NTD OTC PAD ___ OPEN FOR CONTROLLED COMM 232 TBC WORK. VERIFY READY TO PROCEED STM WITH S2005 POST LAUNCH SECURING. PTC STM JSTC 111 GYCC *SCC *PSE NET 105 17-0339 NTD ATTENTION IN THE AREA: PA PERSONNEL SUPPORTING PAD ___ OPERATIONS, REPORT TO YOUR SUPERVISOR FOR WORK ASSIGNMENTS. 17-0340 JSTC *SCB LIFE SUPPORT AIRPACK TRUCK LS NET RELEASED. PICK UP PAVS AT 104 SLIDEWIRE BUNKER PRIOR TO RETURNING TO SHOP. 17-0341 +03H30M STM JBPN CONFIGURE HPGN2 AND HPGHE STORAGE PNSA 111 FACILITIES PAD A/B AND VAB ISOLATION/BYPASS VALVES TO NORMAL CONFIGURATION PER M3123. (2 HR) 1065 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DECONFIG NMAJORTEST PSEUDO -------------------------- 17-0342 LPS ISSUE NMAJORTEST PSEUDO TO VALUE 0000 HEXADECIMAL (0 DECIMAL). ACTIVATE HIM'S -------------- 17-0343 NTD LPS ACTIVATE FOLLOWING HIM'S ON 232 GROUND DATA BUS 2/22 FOR POLLING BY GS3A FEP: HIM PAD A OCTAL PAD B OCTAL --- ----------- ----------- 6396 222 275 6397 023 303 6398 032 311 6399 233 316 8020 224 320 8022 025 325 17-0344 LPS IF INHIBITED AT L-15M, ACTIVATE FOLLOWING HIM ON GROUND DATA BUS 4A/24A FOR POLLING BY GS1A FEP: HIM PAD A OCTAL PAD B OCTAL --- ----------- ----------- 6880 056 056 NOT PERFORMED ______ 17-0345 CLHY TBC FSS SAFING AND SECURING PER SU72A36 136 G3254 COMPLETE. TBC NTD 232 NTD *SCC 1066 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CONTINUE POST LAUNCH OPS ------------------------ NOTE POST LAUNCH SECURING PER S2005 MAY COMMENCE PRIOR TO COMPLETION OF POST LAUNCH ENTRY PORTION OF S0007 BY PERSONNEL ALREADY INSIDE PAD GATE, REMAINDER OF S2005 WILL COMMENCE PER NEXT STEP. 17-0346 +03H30M NTD STM TOUR BUSES MAY RESUME PAD TOUR SEC 232 ROUTE. STM JSTC 111 JSTC *SEC 114 17-0347 +03H30M NTD STM JBFX RELEASED FROM MONITORING WSSA 232 OIS CH 232. STM JBFX 111 17-0348 OTC NTD PERFORM SUPPORT OPERATION SUPPORT 232 SETUP 1 TO MOVE TAIR TRAILER NTD STM NO.__________ FROM __________ TO __________. (1 HR) 17-0349 +03H30M NTD CTC POST LAUNCH PORTION OF S0007 STSA | 232 OTC COMPLETE, CONTINUE WITH POST SU72A34 TBC LAUNCH SECURING PER OMI S2005. STM CTC RESUMES DIRECTION OF TEST TEAM *SCC AT CONCLUSION OF CURRENT SHIFT. LPS 17-0350 +03H30M TBC CLOX CONTINUE WITH POST LAUNCH SECURING 136 CLHY PER OMI'S G3254, G3153 AND S2005. CMEC 17-0351 JSTC JFIR (1P10) RETURN LCC BYPASS (S0007) TO NORMAL CONFIGURATION. 1067 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT RELEASE FIRE, EMERGENCY MEDICAL, ENVIRONMENTAL HEALTH AND SECURITY, SAFETY SUPPORT; REQ'D FOR OMI S2005 POST LAUNCH SECURING. 17-0352 +03H30M STM JSTC POST LAUNCH ENTRY PORTION OF JSTC 111 JTCR S0007 COMPLETE. SUPPORT POST PWRA | JCFM LAUNCH (S2005) OR RETURN TO PNSA JCTL NORMAL SUPPORT. HVAA JBEP WSSA JBPN STSA | JBAC JBFX JBWC JBDY NET QBSE 104 17-0353 JSTC JSEP POST LAUNCH ENTRY PORTION OF ELEC 114 GSPN S0007 COMPLETE. SUPPORT POST PNU NET JSAC LAUNCH SECURING (S2005) OR AC 104 JSDY RETURN TO NORMAL SUPPORT. MECH JSQC QA WCRG RGR *SCB LS *SEC SEC JFIR FIRE GSHE HEQ PMEH EH GSUP LOG 17-0354 +03H30M STM GYCC TERMINATE VOICE RECORDING FOR COMM 111 S0007. TEST COMPLETE, GYCC GYCR SUPPORT POST LAUNCH SECURING 117 JYCJ (S2005). JYVO GYCJ JYCD 1068 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FIGURE IS PRINTED AND DISTRIBUTED SEPARATELY FIGURE 8 - RECYCLE CONTROL SEQUENCE (FOR REFERENCE ONLY) 1069 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK FIGURE 8 - RECYCLE CONTROL SEQUENCE (FOR REFERENCE ONLY) 1070 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 18-0000 RECYCLE CONTROL SEQUENCE ------------------------ NOTE OPERATIONS INVOLVING CRIT 1, 1R AND/OR 1S ITEMS ARE CONTAINED IN THE FOLLOWING SEQUENCE/STEPS. THIS IS A CONTINGENCY SEQUENCE. PERFORM ONLY IF RECYCLE IS REQUIRED. ENTIRE SEQUENCE NOT PERFORMED ______ RECYCLE TO T-20 MIN FROM HOLD ----------------------------- OR CUT OFF BETWEEN T-20 MIN (OPS 101 ------------------------------------ TRANSITION) AND T-ZERO (SRB IGNITION) ------------------------------------ NOTE FOLLOWING CRITICAL RECYCLE OPERATIONS MUST BE COMPLETE PRIOR TO PERFORMING NON-CRITICAL RECYCLE ACTIONS. 1. GLS SAFING 2. MCC-H RECYCLE 3. APU SHUTDOWN 4. ECL HTR RECONFIG 5. CUTOFF SAFING SWITCHLIST 6. OAA EXTEND AND LOCK 7. PAYLOAD SAFING (IF REQUIRED) 8. G1 TO G9 TRANSITION 9. POST CUTOFF SAFETY CHECKS 10. S&A SAFING 11. PCMMU TO REMOTE 12. RECONFIG CABIN AND MPS/HYD SWITCHES 13. SCRUB/RECYCLE DECISION 14. ET DRAIN/RECOVERY DECISION 1071 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GLS SAFING ---------- NOTE PERFORM NEXT TWO STEPS IF GLS SAFING IS NOT IN PROGRESS. 18-0001 NTD CGLS PFPK5 (CUTOFF) - PRESS 212 VFY PFPK5 LIGHT YELLOW NOT PERFORMED ______ 18-0002 CGLS PFPK6 (EXECUTE CUTOFF) - PRESS VFY SAFING IN PROGRESS NOT PERFORMED ______ NOTE GLS SAFING WILL AUTOMATICALLY BE INITIATED AT CUTOFF. SPECIFIC OPERATIONS ARE DEPENDENT UPON CUTOFF TIME AND ARE DELINEATED AT THE END OF THIS SEQUENCE. 18-0003 CGLS NTD GLS SAFING HAS STARTED. (MONITOR FOR ERRORS) (PG-3B) NOTE PERFORM NEXT STEP IF HIM 6880 REQUIRED FOR PAYLOAD OPERATIONS. 18-0004 LPS A HI 056 GS1A SCAN. NOT PERFORMED ______ 1072 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- MCC-H RECYCLE ------------- NOTE PERFORM NEXT STEP ONLY IF COUNT PASSED T-9 MINUTES. 18-0005 *FLT PERFORM MCC-H RECYCLE PER SEQ 23. NOT PERFORMED ______ NOTE PERFORM APU SHUTDOWN IF APU'S ARE OPERATING. APU SHUTDOWN ------------ NOT PERFORMED ______ 18-0006 CGLS OTC GLS GO FOR APU SHUTDOWN. 212 18-0007 OTC PLT PERFORM APU SHUTDOWN. 212 18-0008 PLT PANEL R2 APU/HYD APU OPERATE 1 SW - OFF 2 SW - OFF 3 SW - OFF 18-0009 PLT CRT SYS SUMM 2 APU 1 SPEED < 5 PCT APU 2 SPEED < 5 PCT APU 3 SPEED < 5 PCT 18-0010 PLT PANEL R2 APU/HYD APU FUEL TANK VLV 1 SW - CLOSE 2 SW - CLOSE 3 SW - CLOSE 1073 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 18-0011 PLT PANEL R2 APU/HYD APU CNTRL PWR 1 SW - OFF 2 SW - OFF 3 SW - OFF 18-0012 PLT PANEL R2 APU/HYD HYD MAIN PUMP PRESS 1 SW - NORM 2 SW - NORM 3 SW - NORM CAUTION APU SHUTDOWN TO CIRC PUMP START ELAPSED TIME SHALL NOT EXCEED 15 MINUTES. 18-0013 PLT PANEL R2 APU/HYD HYD CIRC PUMP 1 SW - GPC 2 SW - GPC 3 SW - GPC 18-0014 CHYD CRT (VWF19) VERIFY HYD CIRC PUMPS 1-2-3 RESTARTED HYD CIRC PRESS 1-2-3 100-600 PSIA ME PR LN TEMP 1-2-3 60 DEG F (MIN) CRT (VAF30) VERIFY 1 CIRC AUTO A ON 2 CIRC AUTO B ON 3 CIRC AUTO C ON OMRSD S00E00.840-1R 18-0015 PLT OTC APU SHUTDOWN COMPLETE. 212 OTC NTD 1074 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF APU HEATER GROUND COMMANDS WERE REMOVED. (T-10 SEC) 18-0016 OTC CAPU PERFORM APU HEATER ACTIVATION 212 PER SEQ 42 (S0007VL4). NOT PERFORMED ______ 18-0017 CAPU CRT (VWF57) VERIFY APU READY APU 1 - OFF V46X0125E1 APU 2 - OFF V46X0225E1 APU 3 - OFF V46X0325E1 APU OPERATE APU 1 - OFF V46S0126E1 V46S1127E1 APU 2 - OFF V46S0226E1 V46S1227E1 APU 3 - OFF V46S0326E1 V46S1327E1 ISO VLVS 1A/2A/3A - CB CYAN V46X0115E1 1B/2B/3B - CB CYAN V46X0134E1 V46X0215E1 V46X0234E1 V46X0315E1 V46X0334E1 TURBINE SPEED APU 1 - 0 PCT V46R0135A1 APU 2 - 0 PCT V46R0235A1 APU 3 - 0 PCT V46R0335A1 CNTLR PWR APU 1 - OFF V46S0124E1 APU 2 - OFF V46S0224E1 APU 3 - OFF V46S0324E1 18-0018 CAPU RECORD APU RUN TIME: CAPU __________ (RECORD TIME) (END APU SHUTDOWN) APU SHUTDOWN COMPLETE --------------------- 1075 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS IF APU PRE-START ONLY WAS PERFORMED. PERFORM NEXT STEP IF APU FUEL TANK ISOLATION VALVES WERE OPENED. 18-0019 OTC PLT PANEL R2 212 APU/HYD APU FUEL TANK VALVE 1 SW - CLOSE 2 SW - CLOSE 3 SW - CLOSE NOT PERFORMED ______ 18-0020 OTC PLT PANEL R2 212 APU/HYD APU CNTRL PWR 1 SW - OFF 2 SW - OFF 3 SW - OFF NOT PERFORMED ______ 18-0021 OTC PLT PANEL R2 212 APU/HYD HYD MAIN PUMP PRESS 1 SW - NORM 2 SW - NORM 3 SW - NORM NOT PERFORMED ______ 1076 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ECL HTR RECONFIGURATION ----------------------- NOTE PERFORM NEXT THREE STEPS IF COUNTDOWN PROCEEDED PAST T-5 MIN. 18-0022 OTC CDR RECONFIGURE HEATERS. 212 NOT PERFORMED ______ 18-0023 CDR PANEL L2 FLASH EVAPR FEEDLINE HTR A SUPPLY SW - 2 B SUPPLY SW - 2 NOT PERFORMED ______ 18-0024 CDR OTC HTR RECONFIGURATION COMPLETE. 212 OTC NTD NOT PERFORMED ______ 1077 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CUTOFF SAFING SWITCHLIST ------------------------ 18-0025 OTC CDR PANEL F7 212 FLT CNTLR PWR SW - OFF 18-0026 OTC PLT PANEL R1 POWER DISTRIBUTION ESS BUS SOURCE FC 1 SW - OFF FC 2 SW - OFF FC 3 SW - OFF 18-0027 OTC PLT PANEL F8 FLT CNTLR PWR SW - OFF 18-0028 OTC CGSS VERIFY OAA IS EXTENDED, LOCKED AND CONFIGURED FOR RETRACT. PCMMU TO REMOTE --------------- 18-0029 OTC CGLS GLS CONFIRMS VALID OI AND PCMMU 212 ACTIVE. PROCEED WITH PCMMU POWER SWITCH OFF. NOTE DO NOT PERFORM NEXT STEP IF GLS CANNOT VERIFY VALID OI OR ACTIVE PCMMU IN PREVIOUS STEP. 18-0030 OTC CDR PANEL C3 212 OI PCMMU POWER SW - OFF NOT PERFORMED ______ 1078 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM G1 TO G9 TRANSITION IF PASS ALREADY IN G9. G1 TO G9 TRANSITION ------------------- NOT PERFORMED ______ 18-0031 CGLS OTC GLS PRIMARY SAFING COMPLETE. READY FOR 212 G9 TRANSITION. OTC NTD 18-0032 *FLT NTD BFS SPC BUFFER CLEAR. READY | FOR G9 TRANSITION. 18-0033 NTD CMPL VERIFY CONFIGURED FOR G1 TO G9 CLOX GPC OPS TRANSITION. CLHY CAUTION IF LOX EMERGENCY DRAIN IS IN PROGRESS, G1 TO G9 TRANSITION MAY NOT OCCUR UNTIL CLOX SELECTS DRAIN USING LOW RANGE XDCRS PER S1003. 18-0034 NTD OTC PERFORM PASS TRANSITION TO GNC9. 212 OTC CDPS 18-0035 CDPS CURSOR CNTL (VASP9, PG-B) RETURN TO HOST XMIT CURSOR KEY - PRESS CURSOR CNTL (VASP9, PG-B) INHIBIT LCC MONITORING XMIT CURSOR KEY - PRESS 1079 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE IF BFS IS IN OPS 101 OR RUN MODE AND CREW IS UNAVAILABLE TO SUPPORT TRANSITION, SECURE BFS USING, "REMOTE BFS DEACTIVATION" OPTION IN S0007VL5 PRIOR TO G9 RECYCLE. DO NOT PERFORM NEXT TWO STEPS IF VASJ6 ACTIVE. 18-0036 CDPS CURSOR CNTL (SAS01 PG B) DPS INIT DISPLAY (SAS01) XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS01 PG B) TERMINATE OPS MGR 5 (SAS25) XMIT CURSOR KEY - PRESS PFK 2 KEY - PRESS NOT PERFORMED ______ 18-0037 CDPS CONSOLE KYBD VASJ6 PERF PGM KEY - PRESS NOT PERFORMED ______ 1080 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE G9 RECYCLE IS PERFORMED BY SEQUENCER VASJ6. IF BFS IS ACTIVE IN OPS 101, VASJ6 WILL FIRST PROMPT CDR TO PERFORM A BFS RECYCLE TO OPS 0 STANDBY. ONCE BFS RECYCLE IS COMPLETE, PROGRAM WILL TRANSITION PASS TO G9 VIA DEU EQUIVALENT. PASS G9 TRANSITION TAKES APPROXIMATELY 90 SECONDS. NOTED REQUIREMENTS ARE SATISFIED BY COMPLETION OF FOLLOWING THREE STEPS. OMRS S00E00.880-A-1R OMRS S00E00.880-B-1R 18-0038 CDPS PFP (VASJ6) COUNTDOWN RECYCLE - PRESS 18-0039 CDPS CRT (VASJ6 PG-B) FOLLOW COUNTDOWN RECYCLE PROMPTS 18-0040 CDPS CONSOLE CRT (VASJ6 PG-B) VERIFY MSG: RECYCLE COMPLETE 18-0041 COMPLETION OF PREVIOUS THREE STEPS SATISFIES NOTED REQUIREMENTS. OMRSD S00E00.880-A-1R OMRSD S00E00.880-B-1R 1081 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 18-0042 CDPS OTC DPS IS CONFIGURED TO GNC9 DL FORMAT ___. 18-0043 OTC NTD DPS IN G9. 212 TBC G1 TO G9 TRANSITION COMPLETE ---------------------------- 18-0044 NTD CHGD VERIFY ET INTERTANK 02 CONCENTRATION 212 LESS THAN 10,000 PPM. 1082 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM POST CUTOFF SAFETY CHECKS IF PREVIOUSLY PERFORMED FOR AN ABORT. PERFORM POST CUTOFF SAFETY CHECKS ANYTIME A CUT-OFF OCCURS AFTER APU START. POST CUTOFF SAFETY CHECKS ------------------------- NOT PERFORMED ______ 18-0045 NTD PERFORM POST CUTOFF SAFETY CHECKS. 1. NTD CISL VERIFY ORBITER OI PCM DATA VALID. 2. NTD CDPS VERIFY ORBITER DOWNLIST DATA VALID. VERIFY LDB POLLING ACTIVE. 3. NTD CCME VERIFY ENGINE DATA VALID. VERIFY ENGINE COMMAND PATHS GOOD. 4. NTD CSME VERIFY ALL ENGINE PRESSURES AND TEMPERATURES APPEAR NORMAL. 5. NTD CSME VERIFY NO ENGINE LEAK INDICATIONS. 6. NTD CMPL VERIFY NO INDICATION OF FIRE AT AFT ORBITER (AREA ON FD 36, 37, 38, 39) 7. NTD CMPL VERIFY LOX BLEED PATH ESTABLISHED OR LOX DRAIN INITIATED PER S1003. 8. NTD CLHY VERIFY NO UNEXPECTED FIRE DETECTORS TRIPPED. 9. NTD CLHY VERIFY NO SIGNIFICANT LEAKS ON MLP, CROSS-COUNTRY LINES, TSM, STORAGE AREA OR ET VENT SYSTEM. 10. NTD CLHY VERIFY ET LH2 TANK PRESSURE STABLE. 1083 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 18-0045 11. NTD CLOX VERIFY OTV INDICATES NO FIRE OR CON'T LEAKS ON CROSS-COUNTRY LINES, STORAGE AREA, MLP OR TSM. 12. NTD CLOX VERIFY ET LOX TANK PRESSURE STABLE. 13. NTD CPVD VERIFY GN2 PURGE INTERFACE PRESSURES ARE NOMINAL AND VENT DOORS IN NORMAL PURGE CONFIGURATION. 14. NTD CHGD VERIFY NO INDICATION OF HYDROGEN LEAKS IN AFT FUSELAGE. 15. NTD CHGD VERIFY NO INDICATION OF OXYGEN LEAKS IN AFT FUSELAGE. 16. NTD CGSS VERIFY NO INDICATIONS OF FIRE ON CREW ESCAPE ROUTE. 17. NTD CAPU VERIFY APU'S ARE SHUTDOWN AND NO LEAKAGE INDICATIONS. 18. NTD CBHY VERIFY HPU'S ARE SHUTDOWN AND NO LEAKAGE INDICATIONS. 19. NTD CPWR VERIFY SRB IGNITION S&A'S SAFE. 20. NTD CEPD IF CUTOFF OCCURED AFTER T-21 SEC, VERIFY GROUND PIC RACK POWERED DOWN. 21. NTD COOS VERIFY ALL OX/FUEL TANK PRESSURES AND TEMPS STABLE. 22. NTD CBRS VERIFY RANGE SAFETY INHIBITS ON. 23. NTD POST CUTOFF SAFETY CHECKS COMPLETE. POST CUTOFF SAFETY CHECKS COMPLETE ---------------------------------- 1084 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM S&A POST CUTOFF SAFETY CONTINGENCY IF MECS WERE POWERED DOWN DURING ABORT SEQUENCE. S&A POST CUTOFF SAFETY CONTINGENCY ---------------------------------- NOT PERFORMED ______ 18-0046 OTC MS1 PERFORM MEC POWER UP PER OMI S9001VL1. 212 CEPD REPORT COMPLETION. RT OMI LOG NO.__________ 18-0047 NTD TBC PERFORM SRB OI POWER UP PER 212 OMI S9001VL1. REPORT COMPLETION. TBC CPWR 136 RT OMI LOG NO.__________ 18-0048 NTD CPWR REPORT POSITION OF IGN S&A 212 RH SRB IGN S&A: SAFE/ARM LH SRB IGN S&A: SAFE/ARM S&A POST CUTOFF SAFETY CONTINGENCY ---------------------------------- COMPLETE -------- 1085 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM SRB IGN S&A SAFING IF SRB IGN S&A'S ARE ARMED. SRB IGN S&A SAFING ------------------ NOT PERFORMED ______ 18-0049 NTD CPWR PERFORM IGNITION S&A SAFING. 212 18-0050 CPWR CURSOR CNTL (SDC01) SRB OPTION IGN SAF/ARM XMIT CURSOR KEY - PRESS CRT VERIFY SWC01 TERMINATED AND BDE07 IS DISPLAYED. 18-0051 CPWR CURSOR CNTL (BDE07) SAFE LEFT AND RIGHT XMIT CURSOR KEY - PRESS CRT VERIFY BSE06 GPC FORMAT OR VALIDITY FREQ ERROR 18-0052 CPWR PFP (BSE06) CONTINUE - PRESS 18-0053 CPWR CONSOLE KYBD (BWE07) PFK15 - PRESS CRT VERIFY BWE07 TERMINATES AND SDC01 IS DISPLAYED. 18-0054 CPWR NTD IGNITION S&A SAFING COMPLETE. SRB IGN S&A SAFING COMPLETE --------------------------- 1086 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- RSS S&A SAFING -------------- WARNING PERFORM NEXT SIX STEPS IF COUNT PASSED T-5M. 18-0055 NTD RSR POST CUTOFF SAFETY CHECKS COMPLETE. 212 FIRE AND LEAK DETECTOR STATUS SATISFACTORY. REQUEST CONCURRENCE TO PROCEED WITH SRB S&A SAFING. NOT PERFORMED ______ 18-0056 NTD OTC PERFORM SRB RSS S&A SAFING (POST G9 RECYCLE). NOT PERFORMED ______ 18-0057 OTC CPWR VERIFY IGNITION S&A'S SAFE. NOT PERFORMED ______ 18-0058 OTC CDPS DEU EQUIVALENTS AND MEC CRITICAL CEPD CMD'S WILL BE ISSUED MOMENTARILY. NOT PERFORMED ______ 18-0059 OTC CGLS PERFORM SRB RSS S&A SAFING (POST G9 RECYCLE). NOT PERFORMED ______ 18-0060 CGLS OTC SRB RSS S&A'S SAFED AND MEC OTC NTD CRITICAL CMD'S DISABLED. 212 NOT PERFORMED ______ 1087 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF FUEL CELL LOADS HAVE BEEN ADJUSTED TO HIGH RANGE. 18-0061 OTC CEPD PERFORM GROUND POWER CONNECT AND 212 CFCP FC LOAD SHARE ADJUST PER SEQ 55 (S0007VL4). REPORT COMPLETION. OMRSD S00E00.A00 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF COUNT PASSED T-2 MIN. 18-0062 OTC CREW OPEN LEH VISORS. NOT PERFORMED ______ 18-0063 OTC PLT PERFORM MPS HELIUM RECONFIGURATION 212 PER YOUR CHECKLIST PLT PANEL R2 MPS HE ISOLATION A LEFT SW - GPC CTR SW - GPC RIGHT SW - GPC HE ISOLATION B LEFT SW - GPC CTR SW - GPC RIGHT SW - GPC PNEUMATICS HE ISOL SW - GPC 18-0064 PLT OTC MPS HELIUM RECONFIGURATION COMPLETE. CRITICAL SAFING COMPLETE ------------------------ 18-0065 OTC NTD CRITICAL SAFING COMPLETE. 212 1088 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 18-0066 OTC CEPD PERFORM MEC PREFLIGHT BITE EVALUATION. 212 18-0067 CEPD PERFORM CDS QLDB RETRIEVAL ON FD . VERIFY NO MEC FAILURES. ET BIPOD HEATER ACTIVATION -------------------------- NOTE PERFORM NEXT THREE STEPS AS SOON AS PRACTICAL AFTER HOLD/ABORT IF HEATERS HAVE BEEN TERMINATED. 18-0068 TBC CPWR REACTIVATE BI-POD HEATERS. NOT PERFORMED ______ 18-0069 CPWR PFP (TW495) BIPOD HTR PWR - PRESS BIPODS ON - PRESS CRT (TD490) VERIFY BIPOD HTR CURRENTS 0.8 - 1.2 A OMRSD S00E00.991 NOT PERFORMED ______ 18-0070 CPWR TBC ET HEATERS HAVE BEEN ACTIVATED. TBC NTD 212 NOT PERFORMED ______ 1089 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF AUTO ET OPS IS INHIBITED. 18-0071 CPWR PFP (BWE08) PFPK3 KEY - PRESS CRT VERIFY LED 3 - AUTO ET OPS ACT NOT PERFORMED ______ SCRUB DECISION POINT -------------------- NOTE PERFORM NEXT TWO STEPS IF SUBSEQUENT TERMINAL COUNTDOWN RUN WILL BE PERFORMED. 18-0072 NTD OTC NEW T-ZERO WILL BE __________ GMT 212 TBC COUNTDOWN CLOCKS WILL PICK UP AT LPS T-20 MINUTES AND COUNTING AT SPE __________ GMT. STM *SCC *FLT PTC CDR SRO LRD *MIL LD NOT PERFORMED ______ 18-0073 LRD *DCD NEW T-ZERO WILL BE __________GMT. 135 ROC COUNTDOWN CLOCK WILL PICK UP AT CCN EMS T-20 MINUTES AND COUNTING AT LF1 NCC __________GMT. LSO GOMS *SLF NOT PERFORMED ______ 1090 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ELEMENT RECYCLE --------------- NOTE IF SCRUB DECISION HAS BEEN MADE, NTD MAY ELECT TO PROCEED WITH SEQ 30 TO INITIATE LOX DRAIN PRIOR TO COMPLETION OF STEPS IN SEQ 18. 18-0074 NTD OTC PERFORM RECYCLE TO T-20 MIN 212 TBC STATUS PER FOLLOWING SEQUENCES: STM LPS JRPS ORBITER...........SEQ 19 PTC SRB...............SEQ 20 ET................SEQ 21 SUPPORT...........SEQ 22 PAYLOAD...........SEQ 24 ALL TEST TEAM PERSONNEL RETURN TO YOUR NORMAL COMMAND CHANNEL. ORBITER PERSONNEL REMAIN ON OIS CH 212. NTD TO OIS CH 232. NOTE PERFORM ONE OF FOLLOWING TWO STEPS IF SUBSEQUENT TERMINAL COUNTDOWN RUNS WILL BE PERFORMED (NO SCRUB DECLARED). PERFORM NEXT STEP IF CDC WAS STOPPED AT T-01M57S OR EARLIER. 18-0075 NTD TBC RE-ESTABLISH ET LOX REPLENISH 232 AND VERIFY LH2 IN REPLENISH. TBC CLOX 136 CLHY NOT PERFORMED ______ 1091 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF CDC WAS STOPPED AFTER T-01M57S. 18-0076 NTD TBC RE-ESTABLISH ET LOX REPLENISH 232 AND PERFORM LH2 RECOVERY TO TBC CLOX TOPPING/REPLENISH. 136 CLHY NOT PERFORMED ______ 18-0077 OTC NTD ORBITER RECYCLE (SEQ 19) COMPLETE. 232 18-0078 TBC NTD SRB AND ET RECYCLE (SEQ 20 AND 21) 232 COMPLETE. 18-0079 STM NTD SUPPORT RECYCLE (SEQ 22) COMPLETE. 232 18-0080 PTC NTD PAYLOAD RECYCLE (SEQ 24) COMPLETE. | 232 | | 18-0081 NTD OTC IF SCRUB DECISION HAS BEEN 232 TBC ANNOUNCED, PROCEED TO SEQ 30 LPS (S0007 VL3). SPE STM *SCC *FLT PTC CDR SRO LRD *MIL LD NOT PERFORMED ______ 1092 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM PREPS TO RESUME AT T-20 MINUTES IF DECISION TO SCRUB HAS BEEN ANNOUNCED. PREPS TO RESUME AT T-20 MINUTES ------------------------------- NOT PERFORMED ______ IMU PREFLIGHT ALIGN RERUN DECISION ---------------------------------- NOTE CGNC IS BACKUP TO JSC/MER FOR IMU PERFORMANCE. 18-0082 NTD *FLT VERIFY IF IMU PERFORMANCE REQUIRES 232 OTC PREFLIGHT ALIGN OR IMU'S CAN CGNC REMAIN IN GC ALIGN 1 OR INERTIAL. NOTE PERFORM IMU PREFLIGHT ALIGN RERUN IF PREFLIGHT ALIGN REQUIRED. IMU PREFLIGHT ALIGN RERUN ------------------------- NOT PERFORMED ______ IMU PREFLIGHT ALIGN PREPS ------------------------- 18-0083 NTD OTC PERFORM IMU ALIGN PREPS. 232 DO NOT START IMU PREFLIGHT OTC CGNC ALIGN UNTIL DIRECTED. 212 1093 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 18-0084 CGNC CURSOR CNTL (VABM1/VWB19 PG-B) TERM IDLE (ITEM 27) XMIT CURSOR KEY - PRESS START XMIT CURSOR KEY - PRESS 18-0085 CGNC CRT (VSB35 PG-B) DEPRESS PFK2 TO ISSUE SPEC 104 TO CRT 2 18-0086 CGNC APPL PAGE (VSB35 PG-B) PFK2 KEY - PRESS (CRT 2) 18-0087 CGNC CRT (VSB35 PG-A OR VWB19 PG-B) VERIFY IMUS IN TERM IDLE IMU PREFLIGHT ALIGN ------------------- 18-0088 NTD OTC PERFORM IMU PREFLIGHT ALIGN. NEW 232 T-0 WILL BE ___________ GMT. OTC CGNC (75 MIN MINIMUM) 212 NOTE PROCEED WITH ATT DET AT 45 MIN PRIOR TO OPS 101 TRANSITION. BEGIN PREFLIGHT ALIGN AT 40 MIN PRIOR TO OPS 101 TRANSITION. 18-0089 CGNC PROCEED WITH IMU PREFLIGHT ALIGNMENT PER OMI V1123. REPORT COMPLETION. ATT DET (T-0 - 75M)___________GMT PFA (T-0 - 70M)___________GMT RT OMI LOG NO.__________ OMRSD S00E00.890-1R 1094 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IMU PREFLIGHT ALIGN RERUN COMPLETE ---------------------------------- RECYCLE COMPLETE ---------------- 18-0090 NTD LPS VERIFY RECYCLE COMPLETE. 232 JRPS PTC FLT CNTLR PWR - ON ------------------ 18-0091 OTC CDR PANEL F7 212 FLT CNTLR PWR SW - ON 18-0092 OTC PLT PANEL F8 FLT CNTLR PWR SW - ON PCMMU TO PANEL CONTROL ---------------------- 18-0093 OTC CISL PCMMU SWITCH WILL BE CHANGED TO 1. 212 PCMMU BITE BITS 5, 12, 13 AND POSSIBLY 8 AND 11 MAY SHOW FAILED DUE TO BFS AUTO LOAD OF TFL 102 TO 64KB FORMATTER. 18-0094 OTC CDR PANEL C3 OI PCMMU POWER SW - 1 1095 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 18-0095 OTC CISL CRT (SAQ04/VWQ11) 212 VERIFY PCMMU SW SCAN 1 CURSOR CNTL (SAQ04/VWQ11) PCM CONTROL COMMAND - OFF XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT (SAQ04/VWQ11) VERIFY PCMMU COMMAND OFF BITE 1 POWER GOOD 2 MTU GOOD OI DATA VALID OMRSD V75AP0.040-1R 18-0096 NTD OTC REPORT STATUS OF LAUNCH POLYNOMIAL 232 UPDATES. OTC CVFS 212 1096 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE A BFS ONE SHOT DATA TRANSFER MUST BE PERFORMED ONLY IN THE EVENT OF: 1. A LAUNCH POLYNOMIAL UPDATE. 2. A SRM CHAMBER PRESSURE CALIBRATION UPDATE. 3. AN IMU PREFLIGHT CALIBRATION. 4. A RELOAD OF BFS GPC IF NONE OF THE ABOVE CRITERIA ARE MET, DO NOT PERFORM PASS/BFS ONE SHOT DATA TRANSFER. PASS/BFS ONE-SHOT DATA TRANSFER SHOULD BE STARTED APPROXIMATELY 12 MINUTES PRIOR TO OPS 101 TRANSITION. PASS/BFS ONE SHOT DATA TRANSFER ------------------------------- NOT PERFORMED ______ NOTE NOTED REQUIREMENT IS SATISFIED BY COMPLETION OF FOLLOWING FOUR STEPS. | OMRS S00E00.915-1R 18-0097 L-42M OTC CDR PERFORM PASS/BFS TRANSFER PREPS | 212 PER YOUR CHECKLIST. | 18-0098 CDPS CRT (VASJ6 PG-B) | ONE SHOT ENABLED - INVERT GREEN | | 18-0099 CDPS PFP (VASJ6) PFPK1 - PRESS (ONE-SHOT SELECT) 1097 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 18-0100 CDPS CRT (VASJ6 PG B) ONE-SHOT COMPLETE MILESTONE IN INVERT GREEN 18-0101 COMPLETION OF PREVIOUS FOUR STEPS | SATISFIES NOTED REQUIREMENT. OMRSD S00E00.915-1R PASS/BFS ONE SHOT DATA TRANSFER ------------------------------- COMPLETE -------- NOTE RETURN TO OMI CONTROL SEQUENCE AT T-20 MIN RECYCLE ENTRY POINT. PREPS TO RESUME AT T-20 MINUTES COMPLETE ---------------------------------------- 1098 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 19-0000 ORBITER RECYCLE --------------- NOTE THIS IS A CONTINGENCY SEQUENCE. PERFORM ONLY IF RECYCLE IS REQUIRED. ENTIRE SEQUENCE NOT PERFORMED ______ ORBITER RECYCLE CONTROL ----------------------- SECTION 1 --------- NOTE THIS SECTION CONTAINS TEST CONDUCTOR CONTROL STEPS FOR ORBITER SUBSYSTEMS RECYCLE TO T-20 MIN CONFIGURATION (SECTION 2). 19-0001 OTC ALL ALL ORBITER PERSONNEL PERFORM 212 SUBSYSTEM RECYCLE OPERATIONS PER SEQ 19, SECTION 2. 19-0002 OTC CMPS SUPPORT LO2/LH2 RECYCLES PER CMPL OMI S1003/OMI S1004 AND REPORT COMPLETION. 19-0003 OTC CHGD MONITOR HGDS FOR RECYCLE OPERATIONS. REPORT ANY H2 OR O2 INDICATIONS ON COMMAND CHANNEL 212. SAMPLE EACH VEHICLE AREA AT LEAST EVERY 30 MINUTES. SAMPLE SPAN, TEST AND ZERO REFERENCE GASES AT LEAST ONCE EVERY HOUR. IF H2 ZERO GAS BACKGROUND EXCEEDS +/- 60 PPM, PERFORM REMOTE AUTO CALIBRATION. 1099 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 19-0004 CGSS OTC SOUND SUPPRESSION RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. 19-0005 COFC OTC FLIGHT CONTROL RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. 19-0006 CSME OTC RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. 19-0007 CMPS OTC RECYCLE PER S1004 COMPLETE. 19-0008 CMPL OTC RECYCLE PER S1003 COMPLETE. 19-0009 COOS OTC RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. 19-0010 CDPS OTC RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. NOTE PERFORM NEXT STEP IF REQUIRED TO SUPPORT PAYLOAD REQUIREMENTS. 19-0011 CPVD OTC PLB FLOWRATE INCREASED. RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. NOT PERFORMED ______ 1100 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF CUTOFF OCCURRED AFTER APU START (T-5 MIN). 19-0012 CAPU OTC APU COOLDOWN COMPLETE. RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. OMRSD S00E00.710-1R NOT PERFORMED ______ 19-0013 CECL OTC RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. NOTE PERFORM NEXT STEP ONLY IF FUEL CELLS HAVE BEEN TRANSFERRED TO INTERNAL REACTANTS (T-02M35S) AND HOLD IS SUFFICIENT TO REQUIRE TRANSFER TO EXTERNAL REACTANTS. 19-0014 CFCP OTC TRANSFER TO EXTERNAL REACTANTS COMPLETE. NOT PERFORMED ______ 19-0015 CFCP OTC RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. 19-0016 CEPD OTC RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. 19-0017 CGLS OTC RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. 19-0018 OTC NTD ORBITER RECYCLE TO T-20 MIN 232 CONFIGURATION COMPLETE. NOTE RETURN TO RECYCLE CONTROL SEQUENCE 18. 1101 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- ORBITER SUBSYSTEM RECYCLE ------------------------- SECTION 2 --------- FLIGHT CONTROL RECYCLE ---------------------- ECP AI MODE 1: MATCH CMDS TO POSN ---------------------------------- 19-0019 COFC PFP (SAB20/SWB02) PFPK (SWB02) KEY - PRESS 19-0020 COFC PFP (SWB02) PFPK4 (ORB/SRB AI MODE 1) - PRESS OMRSD S00E00.894-1R 1102 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SET NWS CMDS TO 0 DEG --------------------- NOTE FOLLOWING STEP SETS NWS1 AND NWS2 CMDS TO 0 DEG (-0.44 VOLTS). ANY SUBSEQUENT AI MODE 1 WITH SRB WILL RESET CMDS BACK TO 1 DEG (0 VOLTS). 19-0021 COFC CONSOLE KYBD GPCC RFG XMIT CMD KEY - PRESS CURSOR CNTL (RFG ECP) SLOPE VALUE: 2 XMIT CURSOR KEY - PRESS CURSOR CNTL ACT/RGA ID: 0 XMIT CURSOR KEY - PRESS CURSOR CNTL FINAL VALUE: -44 CNTS * XMIT CURSOR KEY - PRESS PFK-1 KEY - PRESS (EXECUTE RFG) *NULL = -44 CNTS = -0.44 VDC = 0 DEG 1103 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DEACTIVATE PROFILE MONITOR -------------------------- 19-0022 COFC APPL PG B (SAB21/VWB05) PFK6 KEY - PRESS (ACTIVATE BYPASS PG) PFK8 KEY - PRESS (CLEAR ALL BYPASSES) PFK15 KEY - PRESS (TERMINATE) 19-0023 COFC OTC FLIGHT CONTROL RECYCLE TO T-20 MINUTE CONFIGURATION COMPLETE. SSME RECYCLE ------------ NOTE SSME GN2 PURGE WILL REMAIN ACTIVE FOR 12 HOURS MINIMUM. PURGE WILL BE SECURED PER V9018. 19-0024 CSME CURSOR CNTL (VAE38) GN2 DISPLAY 1. PRIMARY & SECONDARY CONTROL OVERRIDES - OFF 2. PRIMARY & SECONDARY VENT OVERRIDES - OFF 19-0025 CSME (VAE38) VERIFY GN2 PURGE PRESSURE 573-690 PSIG. OMRSD S00E00.160-1 1104 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF SSME IGNITION OCCURRED OR IF SCRUB/DETANK IS REQUIRED. 19-0026 CSME CURSOR CNTL (VAE38 - GN2) SCR 1 HEATER PWR - ON VERIFY PNL OUT PRI TEMP STABLE AT 130 +/- 10 DEG F. RECORD GMT__________ OMRSD S00E00.161-1 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF COUNTDOWN PROCEEDED PAST T-4 MIN AND IF SUBSEQUENT TERMINAL COUNTDOWN RUNS WILL BE PERFORMED (NO SCRUB DECLARED). 19-0027 CSME PERFORM CONTINGENCY PROCEDURE SSMEC CCME RE-INITIALIZATION OF ENGINE READY MONITORING PER S0007VL5 (SEQ 105). NOT PERFORMED ______ NOTE PERFORM NEXT TWO STEPS AFTER GLS HAS RESET THE COUNTDOWN CLOCK BACT TO T-20 MIN. 19-0028 CCME PFPK (VWE01A) TERMINATE - PRESS 19-0029 CCME CURSOR CNTL (SAS13) VWE01A XMIT CURSOR KEY - PRESS 19-0030 CSME OTC RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. 1105 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- OMS/RCS RECYCLE --------------- 19-0031 OTC COOS PERFORM OMS/RCS RECONFIGURATION. NOTE PERFORM NEXT TWO STEPS IF RECYCLE OCCURS AFTER T-15 MINUTES. 19-0032 COOS CURSOR CNTL (VWD42) C4 - OPEN (L OX XFEED) XMIT CURSOR KEY - PRESS OMRS S00E00.660 NOT PERFORMED ______ 19-0033 COOS CURSOR CNTL (VWD41) C4 - OPEN (L FU XFEED) XMIT CURSOR KEY - PRESS OMRS S00E00.660 NOT PERFORMED ______ 19-0034 COOS OTC OMS/RCS RECONFIGURATION COMPLETE. OMRSD S00E00.660 1106 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SOUND SUPPRESSION SYSTEM RECYCLE -------------------------------- (CGSS) ------ 19-0035 OTC CGSS PERFORM SOUND SUPPRESSION SYSTEM RECYCLE. NOTE PERFORM NEXT STEP IF SS FR CMD BUS IS ON. 19-0036 CGSS CURSOR CNTL (VAJ14) CMD BUS XMIT CURSOR KEY - PRESS (TWICE) OMRSD S00E00.B40-1 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF COUNT WENT PAST 28 SECONDS. 19-0037 OTC CGSS SUPPORT SOUND SUPPRESSION SYSTEM RECYCLE (SEQ 22) ON CH 123. NOT PERFORMED ______ 19-0038 CGSS OTC SOUND SUPPRESSION SYSTEM RECYCLE COMPLETE. 1107 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- INCR PLB FLOWRATE ----------------- NOTE PERFORM NEXT THREE STEPS TO SUPPORT PAYLOAD/EDO REQUIREMENTS. 19-0039 OTC CPVD INCREASE PLB FLOWRATE. REPORT COMPLETION. NOT PERFORMED ______ 19-0040 CPVD CURSOR CNTL (VAM31A) INCREASE PLB FLOWRATE TO: PREVIOUS PLB PURGE FLOWRATE REQ. RECORD FLOWRATE: _____ LBS/MIN NOT PERFORMED ______ 19-0041 CPVD OTC PLB FLOWRATE INCREASED. 212 OTC NTD 232 NTD PTC NOT PERFORMED ______ 1108 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- GLS RECYCLE ----------- NOTE PERFORM NEXT TWO STEPS ONLY IF A SECOND LAUNCH ATTEMPT IS MADE THE SAME DAY. 19-0042 OTC CGLS RECYCLE GLS TO T-20 MIN CONFIGURATION PER SEQ 65. NOT PERFORMED ______ 19-0043 CGLS OTC GLS RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. NOT PERFORMED ______ 19-0044 CGLS VERIFY GLS S/W EXECUTED SAFING COMMANDS/ VERIFICATIONS AS LISTED BELOW. POST- TEST DATA RETRIEVALS MAY BE UTILIZED TO DETERMINE NOT-PERFORMS FOR CUTOFF TIME, SITE, OR EVENT DEPENDENT ACTIONS. NP OPT GLS SAFING ACTION OMRS NO. REQD ----------------- -------- ---- 1. STOP GROUND/VEHICLE CLOCKS S00E00.940 2. CMD DECODERS PWR ON S00E00.980-1R NP_____ 3. UNLOCK SRB FWD MDMS S00E00.930-1R NP_____ 4. SAFE SRB IGN S/A S00E00.750-1 NP_____ 5. TERM LO2 PREPRESS S00E00.460 NP_____ 6. GCU COOLING RECONFIG S00E00.870-1R NP_____ 7. DISARM H2 BURN SYS S00E00.B70 NP_____ 8. INHIBIT SRB RSS S00E00.760-1R NP_____ 9. UNLOCK SRB AFT MDMS S00E00.950-1R NP_____ 10. SRB APU TURBINE OVERSPEED S/D C.L. S00E00.720 NP_____ 11. HPU SHUTDOWN SEQ S00E00.721-A-1 NP_____ 12. CLOSE LO2 POGO VALVES S00E00.B85 NP_____ 13. OPEN LO2 OVBD BLEED VLVS S00E00.B90-1 NP_____ 14. OPEN LO2 OVBD BLEED VLVS S00E00.B85 NP_____ 15. START MPS GN2 PURGE S00E00.160-1 NP_____ 16. INITIATE PURGE SEQ. 3 S00E00.150-1R NP_____ 17. MFV HTRS ON S00E00.305 NP_____ 18. SAFE SRB RSS S AND A S00E00.751-1 NP_____ 1109 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 19. VERIFY SRB IGN PIC CAP DISCHARGED S00E00.800-1R NP_____ 20. OAA EMERGENCY EXTEND S00E00.B80 NP_____ 21. SSME S/D VERIF S00E00.070-1 NP_____ 22. CLOSE LO2 PREVALVES S00E00.B90-1 NP_____ 23. CLOSE POGO VALVES AFTER ABORT S00E00.B90-1 NP_____ 24. CLOSE LH2 PREVALVES S00E00.205-1 NP_____ 25. FIRE DETECTORS ON S00E00.B60-1 NP_____ 26. VERIFY/POSITION VENT DOORS S00E00.050 NP_____ 27. FIRE INHIBIT COMMANDS ON S00E00.790-1R NP_____ 28. SS WATER SYSTEM SECURING S00E00.B50-1 NP_____ 29. ET VENT ARM PIC CAPS DISCHARGED S00E00.810-1R NP_____ 30. T-0 UMB PIC CAPS DISCHARGED S00E00.820-1R NP_____ 31. SRB HOLDDOWN POST PIC CAPS DISCHARGED S00E00.830-1R NP_____ OMRSD S00E00.940-1 (SLPG2) OMRSD S00E00.980-1R (SLPG2) OMRSD S00E00.930-1R (SLPG2) OMRSD S00E00.750-1 (SLPG2) OMRSD S00E00.460 (SLPG2) OMRSD S00E00.870-1R (SLPG2) OMRSD S00E00.B70 (SLPG2) OMRSD S00E00.760-1R (SLPG2) OMRSD S00E00.950-1R (SLPG2) OMRSD S00E00.720 (SLPG2) OMRSD S00E00.721-A-1 (SLPG2,SLPA1) OMRSD S00E00.B85 (SLPG2) OMRSD S00E00.B90-1 (SLPG2) OMRSD S00E00.160-1 (SLPG2) OMRSD S00E00.150-1R (SLPG2) OMRSD S00E00.305 (SLPG2) OMRSD S00E00.751-1 (SLPG2) OMRSD S00E00.800-1R (SLPG2) OMRSD S00E00.B80 (SLPG2) OMRSD S00E00.070-1 (SLPG2) OMRSD S00E00.205-1 (SLPG2) OMRSD S00E00.B60-1 (SLPG2) OMRSD S00E00.050 (SLPG2) OMRSD S00E00.790-1R (SLPG2) OMRSD S00E00.B50-1 (SLPG2) OMRSD S00E00.810-1R (SLPG2) OMRSD S00E00.820-1R (SLPG2) OMRSD S00E00.830-1R (SLPG2) 1110 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- DPS RECYCLE ----------- NOTE LDB SWITCHING WILL OCCUR DURING CMD DECODER BSR READ. 19-0045 CDPS CRT (VAS59 PG B) LA1 ON LF1 ON LM1 ON (EDO MISSIONS ONLY) 19-0046 CDPS CURSOR CNTL (SAS01 PG B) DPS XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS01 PG B) MDM BSR READ PROGRAM (VAS93) XMIT CURSOR KEY - PRESS PFK 2 KEY - PRESS NOTE POWER TRANSIENT BIT (BSR=X8000) MAY BE SET IN BSR IF COUNT WENT PAST T-10 SEC. 19-0047 CDPS CURSOR CNTL (VAS93 PG B) PORT 1 XMIT CURSOR KEY - PRESS PFK 5 KEY - PRESS (FOLLOW PROGRAM PROMPTS) 19-0048 CDPS HOME CMD KEY - PRESS GPCC LDBC XMIT CMD KEY - PRESS CURSOR CNTL ($GM) POLL GSE ON LDB # 2 XMIT CURSOR KEY - PRESS PFK 1 KEY - PRESS 1111 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 19-0049 CDPS CURSOR CNTL (VAS93 PG B) PORT 2 XMIT CURSOR KEY - PRESS PFK 5 KEY - PRESS (FOLLOW PROGRAM PROMPTS) 19-0050 CDPS APPL PAGE (VAS93, PG-B) PFK 15 KEY - PRESS 19-0051 CDPS HOME CMD KEY - PRESS GPCC LDBC XMIT CMD KEY - PRESS CURSOR CNTL ($GM) POLL GSE ON LDB # 1 XMIT CURSOR KEY - PRESS PFK 1 KEY - PRESS 19-0052 CDPS CRT (VAS59 PGB) POLLING ACTIVE ON LDB1 NOTE DO NOT PERFORM NEXT STEP IF SCRUB DECLARED. 19-0053 CDPS CURSOR CNTL (VASP9, PG-B) ACTIVATE LCC MONITORING XMIT CURSOR KEY - PRESS PFK1 KEY - PRESS NOT PERFORMED ______ 19-0054 CDPS CONSOLE KYBD (VASJ6 PG B) PFK1 - PRESS (RECYCLE CPLT CONTINUE) PFK1 - PRESS (BSR CONTINUE) PFK1 - PRESS (NBAT CONTINUE) 1112 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 19-0055 CDPS CONSOLE KYBD HOME CMD KEY - PRESS ISSU N72IV101D #B00B XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS HOME CMD KEY - PRESS C CO _DEU2G LDBA C11 XMIT CMD KEY - PRESS 19-0056 CDPS OTC RECONFIGURE TO T-20 MINUTE CONFIGURATION COMPLETE. ECLSS RECYCLE ------------- 19-0057 CECL CONSOLE KYBD SET V61K2711YL OFF XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS 1113 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- EPDC RECYCLE ------------ NOTE DO NOT PERFORM GROUND PIC RACK POWER UP UNLESS GLS POWERED PIC RACKS DOWN (AFTER T-21 SEC) AND ANOTHER LAUNCH ATTEMPT WILL BE MADE. GROUND PIC RACK POWER UP ------------------------ NOT PERFORMED ______ 19-0058 CEPD CURSOR CNTL (VWC10) GND SYS - ON XMIT CURSOR KEY - PRESS CRT (VWC10) VERIFY GND AND CPA VOLTAGES FOR H2 BURN AND LAUNCH RELEASE SYSTEMS ARE GREATER THAN 26 VDC. 19-0059 CEPD CRT (VWC10) VERIFY ALL SRB IGN, TSM, HDP LANYARD AND ETVAS PIC CAP VOLTS LESS THAN 1.5 VDC. GROUND PIC RACK POWER UP COMPLETE --------------------------------- 19-0060 CEPD OTC RECYCLE TO T-20 MIN CONFIGURATION COMPLETE. 1114 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- FC/PRSD RECYCLE --------------- NOTE PERFORM NEXT TWO STEPS ONLY IF FUEL CELLS HAVE BEEN TRANSFERRED TO INTERNAL REACTANTS (T-02M35S) AND HOLD IS SUFFICIENT TO REQUIRE TRANSFER TO EXTERNAL REACTANTS. 19-0061 CFCP TRANSFER TO EXTERNAL REACTANTS PER OMI V1040.003 ON OIS CH 153. NOT PERFORMED ______ 19-0062 CFCP OTC TRANSFER TO EXTERNAL REACTANTS COMPLETE. OMRSD S00E00.670 NOT PERFORMED ______ 1115 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM PRSD CRYO HEATER ACTIVATION IF CUTOFF OCCURRED AFTER T-10 SECONDS. PRSD CRYO HEATER ACTIVATION --------------------------- NOT PERFORMED ______ NOTE FOLLOWING STEPS REINITIATE TANK HTR LPS AUTO COMMANDS BY CYCLING OFF (TO RESET AUTO COMMAND PSEUDOS) THEN TO AUTO (ISSUING AUTO COMMANDS). 19-0063 CFCP CURSOR CNTL (VWR70, PG-B) LH2 TK1 HTR CNTL AB OFF BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN CURSOR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN CURSORR CNTL LH2 TK2 HTR CNTL AB OFF BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN 1116 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 19-0063 CURSOR CNTL CON'T AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN NOTE PERFORM NEXT STEP ONLY IF TK3 INSTALLED. 19-0064 CFCP CURSOR CNTL (VWR70, PG-B) LH2 TK3 HTR CNTL AB OFF BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN CURSOR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN NOT PERFORMED ______ 1117 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP ONLY IF TK4 INSTALLED. 19-0065 CFCP CURSOR CNTL (VWR70, PG-B) LH2 TK4 HTR CNTL AB OFF BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN CURSOR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN NOT PERFORMED ______ NOTE PERFORM NEXT STEP ONLY IF TK5 INSTALLED (EXCEPT OV-102). 19-0066 CFCP CURSOR CNTL (VWR70, PG-B) LH2 TK5 HTR CNTL AB OFF BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN CURSOR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN NOT PERFORMED ______ 1118 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 19-0067 CFCP CURSOR CNTL (VWR70, PG-B) LO2 TK1 HTR CNTL AB OFF BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN CURSOR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN CURSOR CNTL LO2 TK2 HTR CNTL AB OFF BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN CURSOR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN 1119 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP ONLY IF TK3 INSTALLED. 19-0068 CFCP CURSOR CNTL (VWR70, PG-B) LO2 TK3 HTR CNTL AB OFF BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN CURSOR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN NOT PERFORMED ______ 1120 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP ONLY IF TK4 INSTALLED. IN NEXT STEP, "B" WILL NOT BE DISPLAYED FOR OV-102 FIVE TANK CONFIGURATION. 19-0069 CFCP CURSOR CNTL (VWR70, PG-B) LO2 TK4 HTR CNTL AB OFF BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN CURSOR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN NOT PERFORMED ______ 1121 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP ONLY IF TK5 INSTALLED. IN NEXT STEP, "B" WILL NOT BE DISPLAYED FOR OV-102 FIVE TANK CONFIGURATION. 19-0070 CFCP CURSOR CNTL (VWR70, PG-B) LO2 TK5 HTR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUTO CYAN CURSOR CNTL AB AUT BLK XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS CRT VERIFY AUT INV CYAN NOT PERFORMED ______ NOTE PERFORM NEXT THREE STEPS TO REINITIATE TANK VAC-ION CMDS. 19-0071 CFCP CRT (VWR70, PG-B) VERIFY TRANSFER TO EXTERNAL REACTANTS COMPLETE AND ALL TANK HTR EVENTS ARE OFF. NOT PERFORMED ______ 19-0072 CFCP CONSOLE KYBD VARAI PERFORM PROGRAM KEY - PRESS VERIFY TANK HTR MONITOR PGM ACTIVE NOT PERFORMED ______ 1122 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE NEXT STEP TERMINATES VARAI WITH BOTH HTR CONTROL LOGIC AND EMON NOTIFICATION INHIBITED. 19-0073 CFCP CONSOLE KYBD (VARAI) PFK1 KEY - PRESS 3 TIMES NOT PERFORMED ______ PRSD CRYO HEATER ACTIVATION COMPLETE ------------------------------------ 19-0074 CFCP OTC RECYCLE TO T-20 MINUTES COMPLETE. APU RECYCLE ----------- NOTE PERFORM NEXT TWO STEPS IF CUTOFF OCCURED AFTER APU START (T-5 MIN). 19-0075 CAPU PERFORM APU COOLDOWN PER S0007VL4 (SEQ 42). REPORT WHEN COMPLETE. NOT PERFORMED ______ 19-0076 CAPU OTC APU COOLDOWN COMPLETE. APU RECONFIGURE TO T-20 MINUTE CONFIGURATION COMPLETE. NOT PERFORMED ______ ORBITER RECYCLE COMPLETE ------------------------ 19-0077 OTC NTD ORBITER RECYCLE TO T-20 MINUTE 232 CONFIGURATION COMPLETE. 1123 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 1124 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 20-0000 SRB RECYCLE ----------- NOTE OPERATIONS INVOLVING CRIT 1, 1R AND/OR 1S ITEMS ARE CONTAINED IN THE FOLLOWING SEQUENCE/STEPS. THIS IS A CONTINGENCY SEQUENCE. PERFORM ONLY IF RECYCLE IS REQUIRED. ENTIRE SEQUENCE NOT PERFORMED ______ 20-0001 NTD TBC PERFORM SRB T-20 MINUTE RECYCLE 232 ON OIS CH 136. 20-0002 CPWR TBC CRT (BWE08) 136 ALL PIC VOLTS 0 +/- 1.5 VDC LH/RH IGN S&A SAFE 20-0003 CPWR CURSOR CNTL (BWE01) EMON OPTIONS XMIT CURSOR KEY - PRESS 20-0004 CPWR CURSOR CNTL (BKE03) A ALL EMONS XMIT CURSOR KEY - PRESS CRT VERIFY ALL EMONS ARE ACTIVE 20-0005 CPWR PFP (BKE03) PFK15 KEY - PRESS 1125 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CAUTION RSRM IGNITER TEMPERATURE SENSORS SHALL NOT EXCEED 125 DEG F. RSRM SEGMENT JOINT TEMPERATURE SHALL NOT EXCEED 123 DEG F. NOTE PERFORM NEXT FOUR STEPS ONLY IF SRB JOINT HEATERS HAVE BEEN TURNED OFF. DO NOT PERFORM NEXT FOUR STEPS IF LAUNCH SCRUBBED FOR 24 HOURS OR MORE. 20-0006 TBC CPWR REACTIVATE SRB FIELD JOINT AND IGNITER HEATERS. NOT PERFORMED ______ 20-0007 CPWR CURSOR CNTL (BDE11) AUTO SEQUENCING - ALL XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 20-0008 CPWR CRT (BDE11) VERIFY ALL HTR PWR INDICATIONS ON ALL AUTO SEQ ACT NO FAILURE MESSAGES DISPLAYED OMRSD S00E00.740 OMRSD S00E00.742 OMRSD S00FA0.960 OMRSD S00FA0.970 NOT PERFORMED ______ 1126 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PROGRAM BWE11 MUST REMAIN ACTIVE THROUGH T-0. 20-0009 CPWR TBC SRB FIELD JOINT AND IGNITER HEATERS ACTIVATED. NOT PERFORMED ______ RSS/RCVY BATT AMP-HR VERIFICATION --------------------------------- 20-0010 TBC CPWR PERFORM RSS/RCVY BATTERY AMP-HOUR 136 VERIFICATION. 20-0011 CPWR CONSOLE KYBD CDS ENABLE KEY - PRESS 20-0012 CPWR CONSOLE KYBD (HI-TRAX) CDS SIGN ON KEY - PRESS 20-0013 CPWR CONSOLE KYBD CDS BREAK KEY - PRESS ATHIS_(TCID)# CDS XMIT KEY - PRESS 20-0014 CPWR CRT VERIFY AMP-HRS REMAINING EXCEEDS AMP-HRS REQUIRED FOR LAUNCH (AHRL) FOR ALL BATTERIES. OMRSD S00FB0.370 20-0015 CPWR TBC RSS/RCVY BATTERY AMP/HOUR VERIFICATION COMPLETE. 1127 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SRB DPS RECYCLE --------------- 20-0016 TBC CBDP PERFORM SRB MDM RECYCLE. 136 NOTE LL1 AND LR1 ACTIVE PORT BSR WILL = X3000 IF COUNT WENT BELOW T - 55 SEC. LL2 AND LR2 ACTIVE PORT BSR WILL = X3000 IF COUNT WENT BELOW T-13 SEC. IF GLS RECYCLE RESULTS IN UNLOCK CMD ISSUED TO AN EMDM THAT WAS NOT LOCKED, THE ACTIVE PORT BSR WILL = X1000. 20-0017 CBDP CURSOR CNTL (SAS05 PG B) DPS XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS05 PG B) SRB MANUAL TEST SEL XMIT CURSOR KEY - PRESS PFK2 KEY - PRESS 20-0018 CBDP CURSOR CNTL (BSM06 PG B) BSR READ PORT 1&2 XMIT CURSOR KEY - PRESS CRT (BSM06 PG B) VERIFY BSR'S NOMINAL 20-0019 CBDP PFP (BSM06) PFPK5 (CONTINUE) - PRESS 20-0020 CBDP CURSOR CNTL (BSM06 PG B) LOCK STATUS TEST XMIT CURSOR KEY - PRESS VERIFY ALL MDMS UNLOCKED 1128 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 20-0021 CBDP APPL PAGE (BSM06 PG-B) PFK-5 - PRESS 20-0022 CBDP PFP (BSM06) PFPK1 (TERMINATE) - PRESS 20-0023 CBDP TBC SRB MDM RECYCLE COMPLETE. 136 NOTE PERFORM NEXT STEP IF SRB AFT SKIRT GN2 PURGE IS ON AND THERMAL CONDITIONING IS NOT REQUIRED. 20-0024 TBC CBHY TERMINATE SRB AFT SKIRT GN2 136 PURGE. REPORT COMPLETION. CBHY CURSOR CNTL (BAT04) SRB AFT SKIRT GN2 PURGE (HEATER) CMD - OF (VALVING) (MAIN) PRI - CL SEC - CL LOW PRI - CL SEC - CL DC PWR PRI - OF SEC - OF CRT (BAT04) SRB AFT SKIRT GN2 PURGE PURGE OFF NOT PERFORMED ______ 1129 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT TWO STEPS IF THERMAL CONDITIONING IS REQUIRED. 20-0025 TBC CBHY CONFIGURE SRB AFT SKIRT GN2 PURGE TO LOW FLOW RATE. REPORT COMPLETION. NOT PERFORMED ______ 20-0026 CBHY CURSOR CNTL (BAT04) SRB AFT SKIRT GN2 PURGE (VALVING) (LOW) PRI - OP SEC - OP (MAIN) PRI - CL SEC - CL (HEATER) CMD - ON CRT SRB AFT SKIRT GN2 PURGE (TEMPERATURE/PRESSURE) PRG ON NOT PERFORMED ______ 1130 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM SRB APU N2H4 MANIFOLD REFILL AND BEARING SOAK IF ANY SRB APU HOTFIRE OCCURRED IN S0007, AND IF SAME DAY LAUNCH RECYCLE TO T-20 MINUTES IS IN WORK. SRB APU N2H4 MANIFOLD REFILL AND -------------------------------- BEARING SOAK ------------ NOT PERFORMED ______ NOTE DO NOT REMOVE SRB OI POWER UNTIL SRB APU N2H4 MANIFOLD REFILL IS COMPLETE. DURING FIV CYCLES GAS GENERATOR BED TEMPERATURES SHALL BE MONITORED FOR ANY RISE IN TEMPERATURE. (SHALL NOT INCREASE MORE THAN 20 DEGREES) NOTED OMRS REQUIREMENTS SATISFIED BY COMPLETION OF NEXT 11 STEPS. OMRS S00E00.721-B 20-0027 TBC CBHY PERFORM N2H4 MANIFOLD REFILL AND BEARING SOAK. 20-0028 TBC CBHY CRT (BAT04) 136 VERIFY VEHCLE GAS GENRTR TEMP LEFT A (LESS THAN 220 DEG F) LEFT B (LESS THAN 220 DEG F) RIGHT A (LESS THAN 220 DEG F) RIGHT B (LESS THAN 220 DEG F) 1131 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 20-0029 CBHY CRT (BAT04) READ AND RECORD (STARTING TEMPERATURES) VEHCLE GAS GENRTR TEMP RECORD: LEFT A __________ BD (ROCK) LEFT B __________ BD (TILT) RIGHT A __________ BD (ROCK) RIGHT B __________ BD (TILT) 20-0030 CBHY CURSOR CNTL (BAT04) VEHCLE UPDT (BLOCK) XMIT CURSOR KEY - PRESS NOTE DISCRETE DATA UPDATE 20-0031 CBHY CRT (BAT04) VEHCLE FUEL SUPPLY MODULE SEC VLV LEFT A (CL) GREEN CURSOR CNTL ISO VLV LEFT A - OP WAIT 10 SEC MINIMUM THEN LEFT A - CL 1132 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 20-0032 CBHY CRT (BAT04) VEHCLE FUEL SUPPLY MODULE SEC VLV LEFT B (CL) GREEN CURSOR CNTL ISO VLV LEFT B - OP WAIT 10 SEC MINIMUM, THEN LEFT B - CL 20-0033 CBHY CRT (BAT04) VEHCLE FUEL SUPPLY MODULE SEC VLV RIGHT A (CL) GREEN CURSOR CNTL ISO VLV RIGHT A - OP WAIT 10 SEC MINIMUM, THEN RIGHT A - CL 20-0034 CBHY CRT (BAT04) VEHCLE FUEL SUPPLY MODULE SEC VLV RIGHT B (CL) GREEN CURSOR CNTL ISO VLV RIGHT B - OP WAIT 10 SEC MINIMUM, THEN RIGHT B - CL 1133 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 20-0035 CBHY CRT (BAT04) READ AND RECORD (ENDING TEMPERATURES) VEHCLE GAS GENRTR TEMP RECORD: LEFT A __________ BD (ROCK) LEFT B __________ BD (TILT) RIGHT A __________ BD (ROCK) RIGHT B __________ BD (TILT) 20-0036 CBHY VERIFY ENDING TEMPERATURES DID NOT INCREASE MORE THAN 20 DEGREES FROM STARTING TEMPERATURES FOR LEFT ROCK, LEFT TILT, RIGHT ROCK, RIGHT TILT. 20-0037 CBHY TBC N2H4 MANIFOLD REFILL AND BEARING SOAK COMPLETE. 20-0038 COMPLETION OF PREVIOUS 11 STEPS SATISFIES NOTED OMRS REQUIREMENT. OMRSD S00E00.721-B-1 1134 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT THREE STEPS IF ANY SRB APU HOTFIRE OCCURRED IN S0007 AND IF SAME DAY LAUNCH RECYCLE TO T-20 MINUTES IS IN WORK. 20-0039 TBC CBHY PERFORM SRB HPU GAS GENERATOR 136 HEATER POWER ON. NOT PERFORMED ______ 20-0040 CBHY CURSOR CNTL (BAT04) VEHCLE GAS GENRTR AUT (BLOCK) XMIT CURSOR KEY - PRESS NOT PERFORMED ______ 20-0041 CBHY TBC SRB HPU GAS GENERATOR HEATER POWER 111 ON. NOT PERFORMED ______ SRB APU N2H4 MANIFOLD REFILL ---------------------------- AND BEARING SOAK COMPLETE ------------------------- SRB RECYCLE COMPLETE -------------------- 20-0042 TBC NTD SRB RECYCLE TO T-20 MINUTES COMPLETE. 1135 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 1136 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 21-0000 ET RECYCLE ---------- NOTE THIS IS A CONTINGENCY SEQUENCE. PERFORM ONLY IF RECYCLE IS REQUIRED. ENTIRE SEQUENCE NOT PERFORMED ______ 21-0001 CLHY CLHF MONITOR GH2 LEAKAGE IN FOLLOWING PLACES (GAW02): LD23 - ET GND UMB CAR PL, LESS GLHR7047A THAN 44,000 PPM LD25 - ET GND UMB CAR PL, LESS GLHR7049A THAN 44,000 PPM LD28 - T-0 UMB LH2 TSM, LESS THAN GLHR7057A 44,000 PPM LD32 - T-0 UMB LH2 TSM, LESS THAN GLHR7067A 44,000 PPM LD56 - LH2 FILL IN PRG BOX, LESS GLHR7078A THAN 44,000 PPM LD57 - LH2 FILL IN PRG BOX, LESS GLHR7079A THAN 44,000 PPM LD29 - LH2 TSM, BOTTOM, LESS THAN GLHR7058A 10,000 PPM LD30 - LH2 TSM, TOP, LESS THAN GLHR7059A 10,000 PPM OMRSD S00E00.012-1 21-0002 TBC CMEC IF NOT EXTENDED, EXTEND GVA AND 136 CONFIGURE TO SUPPORT PER OMI G2158. REPORT COMPLETE. NOT PERFORMED ______ 1137 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT FOUR STEPS IF SUBSEQUENT TERMINAL COUNTDOWN RUNS WILL BE PERFORMED (NO SCRUB DECLARED). 21-0003 CLHY TBC RECOVERY FROM TERMINAL COUNT TO REPLENISH COMPLETE. OMRSD S00E00.490-1 OMRSD S00E00.540-1 NOT PERFORMED ______ 21-0004 CLHY TBC LH2 AT FLIGHT LEVEL. 136 NOT PERFORMED ______ 21-0005 CLOX TBC LOX AT FLIGHT LEVEL PER S1003. NOT PERFORMED ______ 21-0006 TBC NTD ET LOX AND LH2 AT FLIGHT LEVEL. ET 212 READY TO RESUME COUNT AT T-20 MIN. ET RECYCLE COMPLETE. NOT PERFORMED ______ 1138 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF A SCRUB HAS BEEN DECLARED (NO SUBSEQUENT TERMINAL COUNTDOWN RUNS WILL BE PERFORMED). LOX TANKING OMRS BUY-OFF TABLE ------------------------------ 21-0007 CLOX COMPLETION OF ET LOX TANKING FROM LOX/MPS PRELIMINARIES THROUGH T-10 SECONDS SATISFIES THE NOTED OMRS REQUIREMENTS. DETAILS OF LOX TANKING ARE SPECIFIED IN S1003. OMRSD S00FB0.090-A-1 OMRSD S00FB0.300-1 OMRSD S00FB0.310-1 OMRSD S00FB0.320-1 OMRSD S00FB0.340-1 OMRSD S00FC0.080-1 OMRSD S00FC0.100-1 OMRSD S00FC0.120-1 OMRSD S00FD0.062-1 OMRSD S00FD0.073-1 OMRSD S00FD0.094-1 OMRSD S00FD0.095-A OMRSD S00FD0.121-A-1R OMRSD S00FF0.101-1 OMRSD S00FF0.145-1 OMRSD S00FM0.043-1 OMRSD S00FM0.050-1 OMRSD S00FM0.060-1 OMRSD S00FM0.321-1 OMRSD S00FM0.330 OMRSD S00FM0.342-1 OMRSD S00FM0.440-1 NOT PERFORMED ______ 1139 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 1140 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 22-0000 SUPPORT RECYCLE --------------- NOTE THIS IS A CONTINGENCY SEQUENCE. PERFORM ONLY IF RECYCLE IS REQUIRED. ENTIRE SEQUENCE NOT PERFORMED ______ NOTE PERFORM NEXT TWO STEPS IF LAUNCH COOLING SPRAYS ARE ACTIVATED. 22-0001 STM JBFX SECURE FIREX WATER LAUNCH WSSA 111 COOLING SPRAYS OF FSS AND MLP. NOT PERFORMED ______ 22-0002 JBFX STM ALL FIREX WATER LAUNCH COOLING WSSA 111 SPRAYS SECURED. STM NTD 212 NOT PERFORMED ______ NOTE PERFORM NEXT TWO STEPS IF FIREX PUMP(S) RUNNING. 22-0003 NTD STM STOP P1 FIREX PUMP(S). WSSA 232 STM JBFX 111 NOT PERFORMED ______ 1141 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 22-0004 JBFX STM ALL FIREX PUMPS HAVE STOPPED. WSSA 111 STM NTD 232 NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF COUNT WENT PAST T-5 MIN. 22-0005 STM JBAC SECURE COOLING TOWER SPRAY HVAA 111 SYSTEM. NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF LAUNCH RECYCLE OCCURS BEFORE T-00M08S. 22-0006 CPDR ACTIVATE BULK DISC RECORDING. PDR INFOTON KYBD #INRC,D RTN KEY - PRESS NOT PERFORMED ______ 1142 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM FIRST SUBSTEP IF RECORDERS WERE STARTED. 22-0007 STM JCFM PERFORM FOLLOWING: 111 1. STOP FACILITY INSTR PMS RECORDERS. NOT PERFORMED ______ SS1 NOTE PERFORM SUBSTEP 2 IF SUBSEQUENT TERMINAL COUNTDOWN RUNS WILL BE PERFORMED. (NO SCRUB DECLARED). 2. RELOAD FACILITY INSTR PMS RECORDERS. NOT PERFORMED ______ SS2 22-0008 JRPS STOP ALL DISPLAY RECORDERS. 22-0009 EEC JYVR STOP VIDEO RECORDING OF OTV COMM 138 CAMERA 080. 22-0010 LPS CLDB CONFIGURE LDBM SUBSYSTEM RECORDING LDB BUS 1 AND BUS 2 IN REJECT MODE. VERIFY LDBM RECORDING IN DUAL-REJECT. 22-0011 LPS CANCEL PENDING FOR ALL FEPS. 22-0012 LPS C1MC CONSOLE KYBD CURSOR CNTL (AWP01 PG-B) TO T-20M RECYCLE TARGET XMIT CURSOR KEY - PRESS EXEC CMD KEY - PRESS 1143 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 22-0013 LPS VERIFY FEP PENDING CANCELLED FOR FOLLOWING FEPS: GPCA OIA ME1 ME2 ME3 22-0014 LPS C1MC AWP01 PG B CANCEL SOURCE 2, 192KB, HIGH RATE VOICE YES PENDING IN PLDA FEP NOTE PERFORM NEXT STEP AFTER CDT ON CRT DISPLAY HOLDING AT T-20 MINUTE. 22-0015 LPS CONSOLE KYBD CURSOR CNTL (AWP01 PG-B) TO RESUME TARGET XMIT CURSOR KEY - PRESS 1144 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 22-0016 LPS IF INHIBITED AT L-15M, ACTIVATE FOLLOWING HIM ON GROUND DATA BUS 4A/24A FOR POLLING BY GS1A FEP: 6880 056 056 NOT PERFORMED ______ 22-0017 JRPS LPS RECYCLE TO T-20 MINUTE CONFIGURATION 127 COMPLETE. LPS STM 111 SOUND SUPPRESSION SYSTEM ------------------------ RECONFIGURATION OPERATIONS -------------------------- NOTE PERFORM NEXT TWO STEPS IF SOUND SUPPRESSION CONTROL WAS TRANSFERRED FROM FR TO CCC. 22-0018 STM JBWC VERIFY SS CONTROL TRANSFER - WSSA 111 FR TO CCC - COMPLETE AS FOLLOWS: CRT (P2A OR P2B) VERIFY SS CCC ENABLE ON (GREEN) SS CCC - ON/FR - OFF ON (GREEN) SS FR ENABLE OFF (YELLOW) SS FR - ON/CCC - OFF OFF (YELLOW) NOT PERFORMED ______ 22-0019 JBWC STM CCC HAS SS SYSTEM CONTROL. WSSA 111 NOT PERFORMED ______ 1145 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DO NOT PERFORM NEXT TWO STEPS IF SS ELEVATED TANK HAS DRAINED OR IF NO CMDS WERE ISSUED. 22-0020 STM JBWC RECONFIGURE SOUND SUPPRESSION WSSA 111 SYSTEM PER OMI M3189.001. NOT PERFORMED ______ 22-0021 JBWC STM SOUND SUPPRESSION WSSA 111 RECONFIGURATION COMPLETE. NOT PERFORMED ______ NOTE DO NOT PERFORM NEXT STEP IF C/O OCCURRED PRIOR TO T-16 SECONDS (PRIOR TO PRE L/O VALVES OPEN) OR IF A 24 HR OR LONGER SCRUB/TURNAROUND IS TO FOLLOW. 22-0022 NTD STM VERIFY SS OPEN COMMAND LOCKOUT WSSA 232 ON. REFILL SS WATER TANK STM JBWC PER OMI M3189.001 (1 HR 30 MIN). 111 NOT PERFORMED ______ 1146 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM TRANSFER CONTROL OF SOUND SUPPRESSION SYSTEM - CCC TO FR IF SOUND SUPPRESSION CONTROL WAS TRANSFERED TO THE CCC AND IS TO BE RETURNED TO THE FIRING ROOM. CONTROL TRANSFER MAY BE PERFORMED IN CONJUNCTION WITH ELEVATED TANK FILL. TRANSFER CONTROL OF SOUND SUPPRESSION ------------------------------------- SYSTEM -CCC TO FR ----------------- NOT PERFORMED ______ 22-0023 STM JBWC VERIFY SOUND SUPPRESSION WATER WSSA 111 SYSTEM HAS BEEN CONFIGURED TO SUPPORT. 22-0024 STM NTD CCC READY TO TRANSFER CONTROL OF 232 SS WATER TO FR. REQUEST CGSS NTD OTC CONTACT JBWC ON CH 123. OTC CGSS 132 22-0025 STM JBWC TRANSFER CONTROL OF SS WATER WSSA 111 SYSTEM TO FR CONTROL. 22-0026 JBWC CGSS VERIFY READY FOR CONTROL WSSA 123 TRANSFER. 1147 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 22-0027 CGSS CURSOR CNTL (VAJ14) VAJ12 - ON VERIFY 1. VERIFY TANK LVL GREATER THAN OR EQUAL TO 258.2 FT 2. GN2 PRESS PT 1 GREATER THAN 1200 PSI, LESS THAN 1700 PSI PT 2 GREATER THAN 1200 PSI, LESS THAN 1700 PSI CMD MEAS --- ---- 3. CCC LOCKOUT ON - - X - 4. CCC ENABLE CMD OFF X - 5. CCC ENABLED IND ON - - X - 6. FR ENABLED IND OFF - - - 7. SS SOL PWR OFF X X BUS ON CMD 8. SS SOL PWR OFF - - BUS OFF CMD 9. SS FR CMD OFF BUS PWR ON CMD 10. PRE L/O VENT OFF - - VLV OPEN CMD 11. PRE L/O VLVS OFF - OPEN CMD IND 12. PRE L/O VLVS ON - - X - CLOSE CMD IND 13. POST L/O VENT OFF - - VLV OPEN CMD 14. POST L/O VLVS OFF - - - OPEN CMD IND 1148 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 22-0027 15. POST L/O VLVS ON - - X - CON'T OPEN CMD IND 16. VV5,6,7,8,9,10 GRAPHIC BLOCKS - SOLID GREEN 17. PREV25,26,27 AND POST V28,29,30 BLOCKS - SOLID GREEN 18. STATUS ARROW - CYCLING 22-0028 CGSS JBWC READY FOR TRANSFER OF SOUND WSSA SUPPRESSION CONTROL TO FIRING ROOM. 22-0029 JBWC CGSS STAND BY FOR CONTROL TRANSFER. WSSA 123 NOTE CCC WILL TRANSFER CONTROL OF SOUND SUPPRESSION SYSTEM TO FIRING ROOM BY PERFORMING NEXT STEP. 22-0030 JBWC CRT (P2A OR P2B) WSSA VERIFY INDICATOR STATE --------- ----- SS CCC ENABLE ON(GREEN) SS CCC-ON/FR-OFF ON(GREEN) SS FR ENABLE OFF(YELLOW) SS FR-ON/CCC-OFF OFF(YELLOW) CURSOR CONTL CURSOR TO "C" OF "SS FR ON/CCC - OFF" XMIT CURSOR KEY - PRESS 1149 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 22-0030 PFP CON'T "PAD A" (NO. 1) OR "PAD B" KEY (NO. 2) - PRESS "TURN ON" KEY (NO. 1) - PRESS CONSOLE KYBD EXEC CMD KEY - PRESS CRT (P2A) OR (P2B) VERIFY INDICATOR STATE --------- ----- SS CCC ENABLE OFF(YELLOW) SS CCC-ON/FR-OFF OFF(YELLOW) SS FR ENABLE ON(GREEN) SS FR-ON/CCC-OFF ON(GREEN) 22-0031 JBWC CGSS SOUND SUPPRESSION SYS TRANSFERED WSSA 123 TO FR CONTROL. PROCEED WITH FR JBWC STM VERIFICATION. 111 22-0032 CGSS VERIFY SS CONTROL TRANSFER COMPLETE BY OBSERVING VAJ14 SKELETON STATUS AS FOLLOWS: CONTROL CCC OFF FR ON 22-0033 CGLS OTC TRANSFER OF SS SYS CCC TO FR 132 COMPLETE. OTC NTD 232 TRANSFER OF SOUND SUPPRESSION ----------------------------- SYSTEM - CCC TO FR COMPLETE --------------------------- 1150 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- SUPPORT RECYCLE COMPLETE ------------------------ 22-0034 STM NTD SUPPORT RECYCLE TO T-20 MINUTE 232 CONFIGURATION COMPLETE. 1151 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 1152 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 23-0000 MCCH RECYCLE ------------ NOTE THIS IS A CONTINGENCY SEQUENCE. PERFORM ONLY IF RECYCLE IS REQUIRED AND COUNTDOWN HAS PROGRESSED PAST T-9 MINUTES. ENTIRE SEQUENCE NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF BFS SPC LOAD HAS OCCURRED AND GPC-5 MODE SWITCH NOT IN HALT. 23-0001 *FLT XMIT BFS SPC BUFFER CLEAR (1000010) NOT PERFORMED ______ 1153 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM REMAINDER OF SEQUENCE IF RECORDERS ARE RUNNING (AFTER T-09M00S). STOP OEX/MADS RECORDERS ----------------------- NOTE THIS STEP MAY BE PERFORMED IN PARALLEL WITH THOSE FOR PAYLOAD, OPS1 AND OPS2 RECORDERS RECYCLE STEPS. PERFORM NEXT SUBSTEP FOR OV-103, OV-104 AND OV-105 ONLY. 23-0002 *FL PERFORM FOLLOWING: 1. XMIT DSM 4618 (MADS RCDR PWR ON) XMIT DSM 4600 (MADS SYSTEM OFF) VERIFY TAPE MOTION STOPPED XMIT DSM 4619 (MADS RCDR PWR OFF) NOT PERFORMED ______ SS1 NOTE PERFORM NEXT SUBSTEP FOR OV-102 ONLY. 2. XMIT DSM 5766 (SCM ALL STOP) XMIT DSM 5736 (SCM ENTER) NOT PERFORMED ______ SS2 NOT PERFORMED ______ 1154 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 23-0003 CISL CRT (SAQ04) VERIFY TAPE MOTION OFF ON MADS/OEX RECORDER. OMRSD S00E00.811 NOT PERFORMED ______ 23-0004 CISL JRPS MADS REALTIME RECORDING NO LONGER REQUIRED. NOT PERFORMED ______ OI RECORDER RECYCLE TO T-20 MINUTES ----------------------------------- NOTE PERFORM NEXT NINE STEPS IF THIS SEQUENCE IS BEING EXECUTED IN SUPPORT OF A RECYCLE TO T-20 MINUTES. 23-0005 *FLT PERFORM FOLLOWING: 1. TRANSMIT DSM 4351 (OPS 1 STOP) 2. TRANSMIT DSM 4451 (OPS 2 STOP) NOT PERFORMED ______ 23-0006 CISL CRT (SAQ04/SWQ01) VERIFY OPS 1 MOTION OFF OPS 2 MOTION OFF OMRSD S00E00.970 NOT PERFORMED ______ 23-0007 *FLT TRANSMIT DSM 4341 (OPS 1 ERASE) (ERASE TIME 12-16 MIN) NOT PERFORMED ______ 1155 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PAYLOAD RECORDER OPERATIONS FOR A RECYCLE TO T-20 MINUTES TURNAROUND ARE MISSION DEPENDENT. RECORDING MAY BE REQUIRED DURING THE RECYLE. 23-0008 *FLT TRANSMIT DSM 4551 (PL RECORDER STOP) NOT PERFORMED ______ 23-0009 CISL CRT (SAQ04/SWQ01) VERIFY PL RECORDER MOTION OFF OMRSD S00E00.975 NOT PERFORMED ______ 23-0010 *FLT CISL VERIFY OPS 1 ERASE COMPLETE. NOT PERFORMED ______ 23-0011 *FLT TRANSMIT DSM 4351 (OPS 1 STOP) NOT PERFORMED ______ 23-0012 *FLT CISL RECORDER RECYCLE TO T-20 MINUTES COMPLETE. NOT PERFORMED ______ MCCH RECYCLE COMPLETE --------------------- 23-0013 *FLT NTD MCCH RECYCLE TO T-20 MINUTES COMPLETE. NOT PERFORMED ______ 1156 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM PAYLOAD RECORDER DATA PLAYBACK IF PAYLOAD RECORDER IS PRESENT AND THERE IS A REQUIREMENT TO DUMP DATA FROM THE PAYLOAD RECORDER FOLLOWING A SCRUB. PAYLOAD RECORDER DATA PLAYBACK MAY BE PERFORMED IN PARALLEL WITH THOSE FOR MADS AND OPS 1. PAYLOAD RECORDER DATA PLAYBACK ------------------------------ NOT PERFORMED ______ 23-0014 *FLT CISL PAYLOAD RECORDER SCRUB PLAYBACK WILL BE PERFORMED ON CHANNEL 155. 23-0015 *FLT *MIL CONFIGURE TO RECEIVE PAYLOAD RECORDER PLAYBACK FROM __________ (PAYLOAD OR EXPERIMENT) AND REPORT COMPLETION. 23-0016 *FLT JRPS CONFIGURE TO RECEIVE PAYLOAD RECORDER PLAYBACK ON RF LINE 6TVM1729 OR 6TVM4650 AND HARDLINE. SET UP DECOM FOR __________ (PAYLOAD OR EXPERIMENT) DATA AT _____KB. REPORT COMPLETION. 23-0017 *FLT CCSE VERIFY READY FOR TERMINATION OF FM *MIL TRANSMISSION OF MAIN ENGINE DATA. 23-0018 *FLT PERFORM FOLLOWING: 1. TRANSMIT DSM 4786 (FM SOURCE - PL RECORDER) 2. TRANSMIT DSM 4551 (PAYLOAD RCDR STOP) 23-0019 CISL CRT (SAQ04/SWQ01) VERIFY PL RCDR MOTION OFF OMRSD S00E00.975 1157 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE THE NEXT FIVE STEPS MAY BE REPERFORMED AS NECESSARY TO FACILITATE AN ACCEPTABLE PAYLOAD RECORDER PLAYBACK. 23-0020 *FLT *MIL START GROUND RECORDERS. STANDBY FOR PAYLOAD RECORDER DATA FOR __________ (PAYLOAD OR EXPERIMENT). MONITOR DATA QUALITY FOR DROPOUTS. 23-0021 *FLT JRPS START GROUND RECORDERS FOR PAYLOAD RECORDER PLAYBACK ON RF AND HARDLINE. 23-0022 *FLT TRANSMIT DSM 45XX (PAYLOAD RCDR TRACK SELECT) (XX = TRACK DESIRED) TRANSMIT DSM 4529 (PL RCDR SPEED 4 SELECT) TRANSMIT DSM 4517 (PL RECORDER RCDR PLAYBACK SERIAL) 23-0023 *FLT ADVISE MILA OF ANY EXPECTED MODULATION DROPOUTS (I.E. TRACK CHANGES). NOTE WAIT FOR BOT, MOTION OFF BEFORE PROCEEDING. 23-0024 *FLT TRANSMIT DSM 4551 (PL RCDR - STOP) 23-0025 *FLT *MIL END OF PL RECORDER DATA PLAYBACK. JRPS STOP RECORDERS. 23-0026 *FLT *MIL REPORT OVERALL DUMP QUALITY. 23-0027 *FLT BASED ON MILA QUALITY REPORT DETERMINE IF A REDUMP OF DATA WILL BE REQUIRED. 23-0028 *FLT CISL PL RECORDER DUMP ACCEPTABLE. PROCEED WITH ERASE. 23-0029 *FLT *MIL HOUSTON DFE WILL ARRANGE FOR PLAYBACK OF DATA TO MCCH. 1158 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF PLAYBACK OF OPS 2 RECORDER WILL NOT BE PERFORMED. 23-0030 *FLT TRANSMIT DSM4785 (FM SOURCE - MAIN ENGINE) 23-0031 *FLT CISL PAYLOAD RECORDER DUMP IS COMPLETE. CCSE *MIL JRPS PAYLOAD RECORDER DATA PLAYBACK ------------------------------ COMPLETE -------- NOTE PERFORMANCE OF OPS RECORDER SCRUB PLABACK IS CONTINGENT UPON OPS 2 RECORDER ACTIVATION. DO NOT PROCEED WITH OPS 2 RECORDER SCRUB PLAYBACK UNTIL AFTER LAST CREW MEMBER LEAVES COMM. THESE STEPS MAY BE PERFORMED IN PARALLEL WITH THOSE FOR MADS AND OPS 1. OPS 2 RECORDER SCRUB PLAYBACK ----------------------------- NOT PERFORMED ______ 23-0032 *FLT CISL OPS 2 RECORDER SCRUB PLAYBACK WILL BE PERFORMED ON CHANNEL ___. 23-0033 *FLT *MIL CONFIGURE TO RECEIVE 960 REVERSE DUMP AND REPORT COMPLETION. 23-0034 *FLT JRPS CONFIGURE TO RECEIVE OPS 2 RECORDER PLAYBACK ON RF AND HARDLINE. REPORT COMPLETION. 1159 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 23-0035 *FLT CCSE VERIFY READY FOR TERMINATION OF FM TRANSMISSION OF MAIN ENGINE DATA. (MAY HAVE BEEN PREVIOUSLY TERMINATED DUE TO PL RECORDER DUMP.) 23-0036 *FLT PERFORM FOLLOWING: 1. TRANSMIT DSM 4784 (FM SOURCE - OPS RECORDER) *FLT 2. TRANSMIT DSM 4451 (OPS 2 RCDR STOP) 3. VERIFY OPS 2 RCDR MOTION - STOP NOTE THE NEXT FIVE STEPS MAY BE REPERFORMED AS NECESSARY TO FACILITATE AN ACCEPTABLE OPS 2 RECORDER PLAYBACK. 23-0037 *FLT *MIL START GROUND RECORDERS. STANDBY FOR OPS 2 RECORDER PLAYBACK. CONFIRM LOCK ON 960 REVERSE DATA AND MONITOR DATA QUALITY FOR DROPOUTS. 23-0038 *FLT JRPS START RECORDERS FOR OPS 2 RECORDER PLAYBACK ON RF AND HARDLINE. 23-0039 *FLT TRANSMIT DSM 44XX (OPS 2 RCDR TRACK SELECT) (XX = TRACK DESIRED) TRANSMIT DSM 4427 (OPS 2 RCDR SPEED SELECT 120 IPS) TRANSMIT DSM 4417 (OPS 2 RCDR PLAYBACK SERIAL) 23-0040 *FLT ADVISE MILA OF ANY EXPECTED MODULATION DROPOUTS (I.E. TRACK CHANGES) 1160 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE WAIT FOR BOT, TRACK 1, MOTION OFF BEFORE PROCEEDING. 23-0041 *FLT TRANSMIT DSM 4451 (OPS RCDR - STOP) 23-0042 *FLT JRPS END OF OPS 2 RECORDER DATA PLAYBACK. STOP RECORDERS. 23-0043 *FLT BASED ON MILA QUALITY REPORT DETERMINE IF REDUMP OF DATA WILL BE REQUIRED. 23-0044 *FLT CISL OPS 2 RECORDER DUMP ACCEPTABLE. PROCEED WITH ERASE. 23-0045 *FLT TRANSMIT DSM4785 (FM SOURCE - MAIN ENGINE) 23-0046 *FLT CISL OPS 2 RECORDER DUMP IS COMPLETE. CCSE *MIL JRPS MCCH RECYCLE COMPLETE --------------------- 23-0047 *FLT NTD MCCH RECYCLE COMPLETE. 1161 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 1162 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 24-000 PAYLOAD IUS RECYCLE | ------------------- | | NOTE | | PERFORM NEXT FIVE STEPS | FOR IUS MISSION (STS-93). | | PERFORM NEXT FIVE STEPS IF | IUS HAS PROGRESSED PAST | L-11 MIN. MARK (NAV FLIGHT | CMD ISSUED) AND IF LAUNCH | HOLD WILL LAST MORE THAN | 60 MINUTES PAST INITIAL | T-0 TIME. | | IUS RECYCLE TO T-20 MIN. | TAKES APPROXIMATELY 20 MIN. | | 24-001 PTC ICTC PERFORM IUS RECYCLE TO T-20 MIN. | 134 PER DOP D290-50020-27. | | NOT PERFORMED ______| | 24-002 PTC NTD REQUEST NEW T-0 GMT. | 212 | T-0 = __________ GMT | | NOT PERFORMED ______| | 24-003 PTC ICTC NEW T-0 IS __________ GMT. | 134 | NOT PERFORMED ______| | 24-004 ICTC PTC IUS RECYCLE COMPLETE. READY TO | 134 RESUME COUNT AT T-20 MINUTES. | | OMRS P018JD.015 | | NOT PERFORMED ______| | 24-005 PTC NTD IUS READY TO RESUME COUNT AT | 212 T-20 MINUTES. | | NOT PERFORMED ______| 1163 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 1164 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 25-000 RESERVED -------- 1165 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 1166 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 26-000 RESERVED -------- 1167 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 1168 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 27-000 LATE CABIN VENT CONTINGENCY OPTION ---------------------------------- NOTE PERFORM THIS SEQUENCE ONLY IF ESTIMATE FOR COMPLETION OF CABIN VENTING IS LATER THAN L-17 MINUTES. ENTIRE SEQUENCE NOT PERFORMED ______ 27-001 NTD OTC IF PURGE FLOW RATE ABOVE 180 LB/MIN, 232 DELAY FLOW REDUCTION UNTIL HAZ GAS OTC CPVD READING ACCEPTABLE. 212 27-002 NTD CGLS HOLD AT T-9 MINUTES WILL BE EXTENDED 232 IF EITHER OF THE FOLLOWING CONDITIONS EXIST: 1. FOR PLB PURGE RATE OF 170 LBS/MIN AND ESTIMATE OF L-TIME LESS THAN 11 MINUTES. 2. FOR PLB PURGE RATE OF 230 LBS/MIN AND ESTIMATE OF L-TIME LESS THAN 14 MINUTES. 27-003 NTD OTC VERIFY AFT O2 LESS THAN 500 PPM AND 232 MIDBODY/PAYLOAD PAY O2 DECREASING. OTC CHGD 212 1169 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PVD/ECS PLB FLOW REDUCTION -------------------------- NOTE PERFORM NEXT STEP AFTER NOTIFICATION OF ACCEPTABLE O2 LIMITS. 27-004 NTD OTC IF PLB PURGE FLOW RATE GREATER THAN 232 180 LB/MIN, ADJUST PLB FLOW RATE OTC CPVD PER SHUTTLE FINAL COUNTDOWN CONTROL 212 SEQUENCE (-06H THRU T-0) (SEQ 16). NOT PERFORMED ______ 1170 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 28-000 HOLD OPTION NO. 1 - UNPLANNED LONG ---------------------------------- DURATION BETWEEN T-9 MIN AND T-5 MIN ------------------------------------ NOTE THIS IS A CONTINGENCY SEQUENCE. PERFORM IF REQ'D BETWEEN T-9 MIN (GLS AUTO SEQ INITIALIZATION) AND T-5 MIN (PRIOR TO APU START) ENTIRE SEQUENCE NOT PERFORMED ______ 28-001 NTD ALL T-_ MINUTES AND HOLDING. 232 CONFIGURE FOR LONG DURATION HOLD AT THIS POINT. 28-002 CGLS VERIFY ONBOARD CDC STOPPED V90W8380C1 IN RESPONSE TO HOLD FLAG. OMRSD S00E00.920-1 1171 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- EXTEND OAA ---------- NOTE PERFORM NEXT FIVE STEPS IF OAA EXTENSION WILL BE PERFORMED. 28-003 NTD CGSS EXTEND OAA. NOT PERFORMED ______ 28-004 CGSS PFP (VAJ02) PFPK-1 VAJ04 CRIT EXT - PRESS PFPK-5 CRIT EXT EXECUTE - PRESS NOT PERFORMED ______ 28-005 CGSS NTD OAA EXTENDED AND LOCKED. NOT PERFORMED ______ 28-006 CGSS PFP (VAJ02) PFPK-6 - PRESS PFPK-3 VAJ07 OAA ACCUM - PRESS PFPK-5 OAA ACCUM EXEC - PRESS NOT PERFORMED ______ 28-007 CGSS CONSOLE KYBD SET GGOR1101E OFF (WHITE RM O2 PUMP) XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS NOT PERFORMED ______ 1172 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLOSE ISO VALVES ---------------- NOTE PERFORM NEXT STEP TO CLOSE APU ISO VALVES. 28-008 OTC PLT PNL R2 APU FUEL TK VLV 1 SW - CLOSE 2 SW - CLOSE 3 SW - CLOSE NOT PERFORMED ______ *FLT COMMANDS ------------- NOTE PERFORM NEXT STEP TO CLEAR BFS SPC BUFFER. 28-009 NTD *FLT BFS SPC BUFFER CLEAR (1000010) NOT PERFORMED ______ 1173 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT FOUR STEPS IF FLT HAS TRANSMITTED THE T-09M00S MULTIPLE REAL TIME COMMANDS. 28-010 NTD *FLT STOP OI/MADS RECORDERS 1. XMIT DSM 4351 V75K6152U (OPS 1 STOP) XMIT DSM 4451 V75K6352U (OPS 2 STOP) 2. XMIT DSM 4551 (IF RAN) (PL RCDR STOP) 3. XMIT DSM 4618 (MADS RCDR PWR ON) 4. XMIT DSM 4600 (MADS SYS - OFF) VERIFY TAPE MOTION STOPPED 5. XMIT DSM 4619 (MADS RCDR PWR OFF) NOTE PERFORM NEXT SUBSTEP ONLY IF ACIP ACTIVE THIS FLOW. 6. FOR OV-102 ONLY XMIT DSM _____ (ACIP OFF) NOT PERFORMED ______ SS6 NOT PERFORMED ______ 1174 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 28-011 CISL VERIFY TAPE MOTION OFF ON ALL RECORDERS. CRT (SAQ04/SWQ01) OPS 1 MOTION OFF OPS 2 MOTION OFF MADS/OEX MOTION OFF OMRSD S00E00.811 OMRSD S00E00.970 NOT PERFORMED ______ 28-012 CISL VERIFY TAPE MOTION OFF ON RCDR. CRT (SAQ04/SWQ01) P/L MOTION OFF OMRSD S00E00.975 NOT PERFORMED ______ 28-013 CISL NTD RECORDER SHUTDOWN COMPLETE. NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF PPOV CAMERA IS INSTALLED AND IS TO BE POWERED DOWN DURING HOLD. 28-014 OTC MS2 PANEL O19 TV TV POWER SW - OFF NOT PERFORMED ______ 1175 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- IGNITER HEATER ACTIVATION ------------------------- CAUTION RSRM IGNITER TEMPERATURE SHALL NOT EXCEED 125 DEG F. NOTE PERFORM NEXT STEP IF DETERMINED BY CPWR, NTD AND LAUNCH DIRECTOR TO MAINTAIN IGN HTR CONTROL SETTINGS AT 100 +/- 1 DEG F FOR START OF T-5 MINUTE COUNT. 28-015 CPWR CURSOR CNTL (BDE11) LH IGN HTR PWR - ON RH IGN HTR PWR - ON LH IGN AUTO SEQ - ACT RH IGN AUTO SEQ - ACT OMRSD S00E00.742 OMRSD S00FA0.620-1R NOT PERFORMED ______ 1176 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE DELAY AT THIS POINT UNTIL READY TO RESUME COUNTDOWN. IF HOLDING DUE TO INTEGRATION CONSOLE FAILURE, RETURN TO COUNTDOWN RE-ENTRY POINT IN T-9 MIN HOLD. IF SCRUB OR RECYCLE IS CALLED WHILE HOLDING AT T-5 MIN, DO NOT PERFORM CONFIGURE TO RESUME COUNTDOWN. CONFIGURE TO RESUME COUNTDOWN ----------------------------- NOT PERFORMED ______ 28-016 NTD CGLS SET CDC TO START COUNTING AT 212 __________GMT. 28-017 NTD OTC CONFIGURE TO RESUME COUNTDOWN 212 TBC AT __________ GMT. STM *FLT PTC *MIL LPS SRO CONFIGURE TO RESUME COUNTDOWN ----------------------------- COMPLETE -------- 1177 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLOCK START IN 5 MINUTES ------------------------ 28-018 -05M00S NTD ALL COUNTDOWN CLOCK WILL START IN (HOLDING) 212 5 MINUTES. L-10M00S 232 OAA RETRACT ----------- 28-019 -05M00S NTD CGSS RETRACT ORBITER ACCESS ARM. (HOLDING) L-10M00S 28-020 CGSS PFP (VAJ02) PFPK-1 VAJ05 OAA EXT/RET - PRESS PFPK-5 OAA EXT/RET EXECUTE - PRESS VERIFY OAA RETRACTED PFPK-6 OTHER OPTIONS - PRESS (TWICE) PFPK-3 VAJ07 OAA ACCUM - PRESS PFPK-5 OAA ACCUM EXECUTE - PRESS 28-021 CGSS CURSOR CNTL (VAJ14) VAJ10 - SELECT B12 - RESET PRI EXT PILOTV B14 - RESET SEC EXT PILOTV PFK15 - PRESS 28-022 CGSS CONSOLE KYBD SET GGOR1101E ON (WHITE RM O2 PUMP) XMIT CMD KEY - PRESS EXEC CMD KEY - PRESS 28-023 CGSS NTD OAA RETRACTED AND RECONFIGURED FOR EXTEND. 1178 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- CLOCK START IN 4 MINUTES ------------------------ 28-024 -05M00S NTD ALL COUNTDOWN CLOCK WILL START IN (HOLDING) 212 4 MINUTES. L-09M00S 232 RECORDER ACTIVATION ------------------- 28-025 -05M00S NTD *FLT ACTIVATE RECORDERS PER (HOLDING) 212 CISL S0007VL4 (SEQ 38). L-09M00S JRPS 28-026 CISL NTD OPS 2 RECORDER ACTIVATED. 212 IGNITER HEATER DEACTIVATION --------------------------- NOTE HEATERS MUST BE DEACTIVATED PRIOR TO RESUMING COUNTDOWN AT T-5 MINUTES. DO NOT PERFORM NEXT STEP IF HEATERS ALREADY DEACTIVATED. 28-027 CPWR CURSOR CNTL (BDE11) LH IGN HTR AUTO SEQ - INH RH IGN HTR AUTO SEQ - INH LH IGN HTR PWR - OFF RH IGN HTR PWR - OFF OMRSD S00FA0.980 NOT PERFORMED ______ 1179 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF PPOV CAMERA IS INSTALLED AND WAS POWERED DOWN DURING HOLD. 28-028 OTC MS2 PANEL O19 TV TV POWER SW - ON NOT PERFORMED ______ CLOCK START IN 3 MINUTES ------------------------ 28-029 -05M00S NTD ALL COUNTDOWN CLOCK WILL START IN (HOLDING) 212 3 MINUTES. L-08M00S 232 CLOCK START IN 2 MINUTES ------------------------ 28-030 -05M00S NTD ALL COUNTDOWN CLOCK WILL START IN (HOLDING) 212 2 MINUTES. L-07M00S 232 CLOCK START IN 1 MINUTE ----------------------- 28-031 -05M00S NTD ALL COUNTDOWN CLOCK WILL START IN (HOLDING) 212 1 MINUTE. L-06M00S 232 1180 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- STORED PROGRAM COMMANDS ----------------------- NOTE IF HOLD OCCURS AFTER TRANSMITTAL OF BFS SPC LOAD, *FLT WILL TRANSMIT SPC BUFFER CLEAR AND NEW BFS SPC LOAD BASED ON UPDATED LIFTOFF TIME, IF REQUIRED. 28-032 -05M00S NTD *FLT TRANSMIT STORED PROGRAM PRE-LAUNCH (HOLDING) 212 COMMANDS (BFS SPC LOAD). NOT PERFORMED ______ 28-033 *FLT VERIFY 2 - STAGE BUFFER AUTO COMPARE AND EXECUTE. NOT PERFORMED ______ OPEN ISO VALVES --------------- NOTE PERFORM NEXT STEP TO OPEN APU ISO VALVES. 28-034 -05M00S OTC PLT PNL R2 (HOLDING) APU FUEL TK VLV L-06M00S 1 SW - OPEN 2 SW - OPEN 3 SW - OPEN NOT PERFORMED ______ 28-035 NTD THE CDC WILL START ON MY MARK. 212 232 3-2-1 MARK 1181 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 28-036 -05M00S NTD T-5 MINUTES AND COUNTING. COUNTING 212 PA NOTE RETURN TO CONTROL SEQUENCE 16 AT T-5 MIN POINT OF DEPARTURE. 1182 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR APPENDIX Z EMERGENCY INSTRUCTIONS ---------------------- SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE EMERGENCY INSTRUCTIONS APPENDIX Z, ARE LOCATED IN VOL 5. 1183 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR EMERGENCY INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 1184 VOLUME 2 OF 5 OMI NO. - S0007VL2 DATE: 07-07-99 REV. - CR END OF OMI 1185 DATE: 1999-07-07 14.10.21 S0007VL2 SHUTTLE COUNTDOWN (LPS) DISTRIBUTION F - FINAL DANE E. BISHOP........................2 JERRY L. GREENWOOD FF-D4-B 3731 PETE WILSON MICHOUD ASSY FACILITY ZK-07 LOCKHEED MARTIN JAMES REED P.O. BOX 29304 EY-C NEW ORLEANS, LA 70189 ROBERT L. WRIGHT ALEX RODRIGUEZ........3 CSR-4222B ZK-86 STEVE HAUSS GARY S. KANE F656 USB-SYS WHIT BARTLETT DEBBIE HAHN PK-D2 NN-M2 FERDINAND JONES MEGAN MISCHKOT AC-58 N/A BOEING NORTH AMERICAN MICHOUD ASSEMBLY FACILIT 6633 CANOGA AVE P.O. BOX 29300 CANOGA PARK, CA 91304 NEW ORLEANS, LA 70189 SUSAN FRAHM DEPT 4250 BOC-005 JAMES C. LAROCQUE CALVIN J. CULBERTSON..................2 F270 FC-51 JILL JAHNKOW.........2 CCAS, FL 32899 FA-99 LISA A. MALONE BOEING NORTH AMERICAN PA-MSB MISSION SUPPORT ROOM BRUCE D. BOUTON 12214 LAKEWOOD BLVD 8A-44 DOWNEY, CA 90241 BOEING DEFENSE & SPACE G CARLTON HALL P.O. BOX 3999 DYN-2 SEATTLE, WA 98124-2499 JOANNE CREECH RODNEY OLSON..........................2 BOC-022 F204 PATTI SKIPPER........8 BOB CHURNELL NN-H2 F260 CHRIS WEAVER.........10 K. GRANT PZ-L USH-440X RTW/MONICA COLEY UNITED SPACE ALLIANCE USK-275 600 GEMINI HOUSTON, TX 77058 TOTAL QTY: 358 FOR CHANGES TO THIS DISTRIBUTION LIST, CONTACT: MARY M. HESTER , USK-187, (407) 861-3301 EXT ELIZABETH C. KLOS , USK-187, (407) 861-3430 EXT DATE: 1999-07-07 14.10.21 S0007VL2 SHUTTLE COUNTDOWN (LPS) DISTRIBUTION F - FINAL AFQA/LGQAB/P. MCDANIEL MV2/D. STAMPER BA/FC-50/W. BRAGG.....................2 JSC, TX 77058 BA/FC-51/ELS DATA FILES MV3/KENNETH BROWN BA/FC-51/J. HAGOOD....................2 JSC, TX 77058 BA/FC-51/J. LEWIS.....................2 NASA/JSC............9 BA/FC-51/N. BIHR......................3 C/O TRANSPORTATION OFFICE BNA SPACEHAB/NANCY CRABTREE...........2 BUILDING 420 SPACEHAB, INC HOUSTON, TX 77058 620 MAGELLAN RD ATTN: DA82/MARY C. THOMAS CAPE CANAVERAL, FL 32920 BLDG 30M, ROOM 235 C07A/J. LECHER NN-L/PAYLOAD ENGINEERING JSC, TX 77058 NN-M1 DM43/RILEY K. ALLISON NN-M2 JSC, TX 77058 NN-M3 EC-B/DAVID SPACEK T-916/V. BUKAUSKAS EI-C-C/NSF CONSOLE THIO-LSS/BRIAN ST. AUBIN EI-C-C/NSF LC39 PROCEDURES USBI-LSS/LIBRARY EI-C-C/PAC CONSOLE USK-078/CCC, C-1 PNEU EI-C-D/NASA VAB SAFETY USK-078/CCC, C-1 WATER EI-C-F/NASA OPF SAFETY USK-078/CCC, C-2 HVAC EP2/LIBRARY USK-078/CCC, C-3 POWER JSC, TX 77058 USK-078/CCC, INTEGRATION ESMC-SEO/CAMPBELL USK-391/SAFETY OPS (PAD B) EV212/D. FAVORS USK-550/VITT OFFICE.....2 JSC, TX 77058 ZA03/DAVID BARNES.......2 LLOYD MUSTIN SSM BOEING NORTH AMERICAN MAIL STOP AE26 555 DISCOVERY DRIVE BOEING NORTH AMERICAN HUNTSVILLE, AL 35806 SPACE SYSTEMS DIV. 3 SLS/DOOT/CAPT. G. FENTRESS P.O. BOX 7009 3 SLS/MA/B. STRACENER....2 DOWNEY, CA 90241-7009 45 SPACE WING/SESL/PAFB MS-E68/R. BAKES AIR-FORCE CCAFS THIOKOL CORP. N/A P.O. BOX 707 45 RANS/DOOB BRIGHAM CITY, UT 84302-0707 (CCAFS) MS3/LIBRARY PHILLIPS PARKWAY/10400 JSC, TX 77058 PATRICK AFB, FL 32925 MT3 CCC LIBRARY..........3 JSC, TX 77058 USK-093 DATE: 1999-07-07 14.10.21 S0007VL2 SHUTTLE COUNTDOWN (LPS) DISTRIBUTION F - FINAL MISSION SUPPORT BRANCH INSTRUM.&P/LSYS.....2 SGS-347 PK-F3 EG&G PROTECTIVESYSTEMS PNEUMATICS ENGINEERING BOC-326 USK-043 PAD ELECTRICAL-SHOP OFFICE NASAFIRE/RESCUE USK-175 IM-SPS-A SECTION NASACOMM/RFSYSTEMS PAD SWING-ARMS-SHOP PK-F3 USK-398 NASA-FLT ELECTR-SYS-SECT..............2 SFOC SAFETY-CONSOLE PK-F USK-399 FLOW DIRECTOR-OFFICE SUPV-SAFETY RELIABILITY-ENGR PH-B2 USK-291 SECTION NASAECLSSSYSTEM PAD-B SWING-ARMS-SHOP PK-G5 USK-425 BOEING P/L-TEST-CONDUCTOR.............6 SRS-SSC OPERATIONS-SAFTEY F214 MU6110 GUIDANCE-AND NAVIGATION TECHNICAL DOC CTR.......50 USK-195 USK-038 GEL LCC-RM-3R18 TSMO SITE-MGRS USK-542 USK-299 KSC-ELECTRO MAGNETIC-ANALYSIS TSMO OMD VC-A USK-075 LCC HAZ-GAS USA INSTRUMENTATION.....2 USK-542 USK-194 LAUNCH DIRECTOR.......................2 USA LAUNCH-OPERATIONS...2 PH USK-C09 ORB MECHANISM VITT OFFICE PK-H5 F204 NASA QA-FR1...........................3 O&C BLDG USK-268 SWING ARMS-ENG'G OTC ORBTESTCONDUCTOR..................4 USK-290 USK-023 ET MECHANICAL-ENG SPC PAD-SAFETY........................3 USK-251 USK-257 ET LH2PAD-A.............2 TEST-OPS PAD-A USK-174 USK-307 ET LH2PAD-B TEST-OPS PAD-B USK-390 USK-389 ET-LOX PAD-A USK-173 DATE: 1999-07-07 14.10.21 S0007VL2 SHUTTLE COUNTDOWN (LPS) DISTRIBUTION F - FINAL ET-LOX PAD-B HAL L. SNOW USK-316 USK-171 MEQ ORB-MECHANISMS-ENG RICHARD H. MURRAY.......2 USK-408 USK-414 OMS/RCS ENG-PADA ROBERT RODRIGUEZ USK-484 USK-198 OMS/RCS ENG-PADB ADMIN J. LAGIOS USK-347 USK-248 CENTRL WRK-PKG-BLD ED DICRISTINA USK-409 USK-305 COMM CONTROL..........................2 CONNIE VONDRELL USK-145 USK-192 TSMO PAD-A TOM WELLS...........2 USK-076 USK-420 TSMO PAD-B MARTIN L. CARLSON USK-404 USK-420 TSMO SUPV-STM.........................3 JUDY HOOPER.........3 USK-299 USK-247 ROBERT T. ROOK II.....................2 STEVE GODFREY.......2 USK-356 USK-241 FRANK A. DEBERNARDO...................3 BILL NUTTER.........5 USK-116 USK-214 NEAL R. GRIFFITH JANIENE L. PAPE USK-112 USK-284 DON GARCEAU PAUL L. QUANDT USK-109 USK-356 THOMAS E. JACOBS......................2 CHARLES E. SWEENEY USK-107 USK-424 JIM TOWNSEND TODD M. GRACOM USK-108 USK-195 SHOE SHOEMAKER PAUL R. GRATSCH.....2 USK-144 USK-195 PAT CHAPPELL SECUR/041399 VEVERA USK-074 USK-229 DENNIS E. LOHAUS CHARLES J. HANNAS USK-069 USK-192 LAURA M. WHITE EARL D. COOLEY USK-372 USK-269 DATE: 1999-07-07 14.10.21 S0007VL2 SHUTTLE COUNTDOWN (LPS) DISTRIBUTION F - FINAL MARK A. HUET BRUCE BAKER USK-246 PK-F3 ERIC D. HENRY JIMBO BOLTON USK-225 USBI-LSS BOB DOUGERT...........................2 BILL CLEVER II USK-356 SK DEAN T. TYRE KATHLEEN A. CONWAY USK-421 USK-669 E HALL III............................2 TERRI L. HERST USK-420 PK-D STEVE VELLIGAN ED MANGO USK-213 PK-D2 RANDY DUNCAN..........................2 SCOTT CHANDLER USK-196 PK-E4 ROBERTO E. GALINANES MICHAEL GARSKE USK-353 DF24 DON GREEN.............................2 JSC, TX 77058 USK-043 STEVE SWICHKOW RTW/SECUR R. HOEFER PK-F6 USK-453 AL DIAZ PEGGY S. HATTAWAY PK-F USK-246 BOB BEIL GARY A. WOODS PK-G3 USK-281 ANDY DIBBERN ANN M. MICKLOS PK-G6 USK-443 PETE CHITKO 062599/HRMS POSTON PK-H6 USK-598 GREG KATNIK PAUL E. BRANDT PK-H7 USK-111 JORGE E. RIVERA OZZIE FISH............................2 PK-H7 USK-314 PHIL WEBER DONALD L. CROUSE II PK-H6 USK-254 PAT MARKEY ANDY BUNDY PK-J PK-E3 RENEE HART DAVID R. SCHECHTER USK-669 PZ-C DONALD G. SIMMONS...3 USK-647 DATE: 1999-07-07 14.10.21 S0007VL2 SHUTTLE COUNTDOWN (LPS) DISTRIBUTION F - FINAL BILL H. HAASE RAY W. NUSS FF-R EV4 BOBBY E. ORR..........................3 JOHNSON SPACE CENTER USK-607 HOUSTON, TX 77058 OLAN J. BERTRAND STEPHEN E. HOLMES CA4 ZK-36 HOUSTON, TX 77058 ROBERT B. LUECKING KEN FORD ZK-86 USK-637 MATTHEW J. HOFMANN RICHARD MIZELL ROC-LSS PK-F6 JIM ALLAMON LARRY E. WILSON ZK-21 USK-412 CANDICE F. NORMAN.......2 ERVIN G. WALKER BOC-349 JCI-VITC-2 JOYCE M. ROZEWSKI ANGELO PACE FA-24 USK-682 TOM HILL ANKER M. RASMUSSEN ASC/ERD-FL USK-705 TAB CHOATE **NO SITE ADDRESS ON FILE** SA21 RANDY DAVIES BOEING - ROCKETDYNE DIVI CSR-3200 MARSHALL SPACE FLIGHT CE CAPE CANAVERAL AFS, FL 32899 BLDG 4202, RM 405 RONALD W. WETMORE HUNTSVILLE, AL 35812 MMC-15 AL SOFGE HAROLD E. REED EC JJ-3-B TONY IPPOLITO JEFF LEVITT MILA F256 NEAL E. VANSCYOC CHUCK GIVENS F224 BOC-342 JAMES B. PARKS EDWARD D. PRISELAC PK-J-B ROCC GARY A. HUBER...........5 45WS/DOR BD-C CCAS, FL 32920 PHIL LINTEREUR..........3 RAYMOND G. PREECE F264 ZK-07 CECIL G. BOGGS JR BOC-323